HomeMy WebLinkAboutAPPROVED, Truss Engineering-328 Palm Breezes Dr Lot 113Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
RE: Job CRMSCMB3
Page 1 of 2
A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946Site Information:
Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE
Lot/Block:Model: CAYMAN 1763
Subdivision: Address:
City: County: St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 7th Ed. 2020 Res. / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-16 Wind Speed: 160
Roof Load: 37.0 psf Floor Load: 0.0 psf
This package includes 23 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
The truss drawing(s) referenced have been prepared by Alpine Engineered Products, Inc. under my direct supervision based on the parameters provided by A-1 Roof Trusses, Ltd.
Truss Design Engineer's Name: Rama Pranav Kristam
My license renewal date for the state of Florida is February 28,2023.
NOTE: The seal on these drawings indicate acceptance of professional engineering
responsibility solely for the truss components shown.
The suitability and use of components for any particular building is the responsibility of the building
designer, per ANSI/TPI-1 Sec. 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction
documents (also referred to at times as 'Structural Engineering Documents') provided by the Building
Designer indicating the nature and character of the work.
The design criteria therein have been transferred to Rama Pranav Kristam PE by [A1 Roof Trusses or
specific location]. These TDDs (also referred to at times as 'Structural Delegated'
Engineering Documents') are specialty structural component designs and may be part of the project's
deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional engineering
responsibility for the design of the single Truss depicted on the TDD only. The Building Designer is
responsible for and shall coordinate and review the TDDs for
compatibility with their written engineering requirements. Please review all TDDs and all related notes. Rama Pranav Kristam, P.E.
4451 St Lucie Blvd. Suite 201
Fort Pierce, FL 34946
No.Seq #Truss Name Date
1 2994 A02 3/18/21
2 2993 A03 3/18/21
3 2992 A04 3/18/21
4 2991 A05 3/18/21
5 2990 A06 3/18/21
6 2989 A07 3/18/21
7 2988 A08 3/18/21
8 2987 A09 3/18/21
9 2986 A10 3/18/21
10 2985 A11 3/18/21
11 2984 B01 3/18/21
12 2983 B02 3/18/21
No.Seq #Truss Name Date
13 2982 B03 3/18/21
14 2981 B04 3/18/21
15 2923 B05 3/18/21
16 2997 C01 3/18/21
17 2979 C02 3/18/21
18 2978 C03 3/18/21
19 2926 C04 3/18/21
20 2976 E01 3/18/21
21 2996 HJ2 3/18/21
22 2975 J1 3/18/21
23 2974 J2 3/18/21
24 STDL01 STD. DETAIL 3/18/21
No.Seq #Truss Name Date
25 STDL02 STD. DETAIL 3/18/21
26 STDL03 STD. DETAIL 3/18/21
27 STDL04 STD. DETAIL 3/18/21
28 STDL05 STD. DETAIL 3/18/21
29 STDL06 STD. DETAIL 3/18/21
30 STDL07 STD. DETAIL 3/18/21
31 STDL08 STD. DETAIL 3/18/21
32 STDL09 STD. DETAIL 3/18/21
33 STDL10 STD. DETAIL 3/18/21
34 STDL11 STD. DETAIL 3/18/21
35 STDL12 STD. DETAIL 3/18/21
36 STDL13 STD. DETAIL 3/18/21
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
RE: Job CRMSCMB3
Page 2 of 2
No.Seq #Truss Name Date
37 STDL14 STD. DETAIL 3/18/21
38 STDL15 STD. DETAIL 3/18/21
39 STDL16 STD. DETAIL 3/18/21
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T2 2x4 SP M-30;
Bot chord 2x4 SP #2 B4 2x4 SP M-30;
Webs 2x4 SP #3 W3 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 95 0.15 11.74
BC 92 11.71 19.13
BC 114 19.26 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1540 /- /- /874 /408 /314
J 1539 /- /- /873 /408 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
J Brg Width = 8.0 Min Req = 1.8
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 908 -2711
C - D 1448 -4534
D - E 1460 -4453
E - F 1628 -4577
Chords Tens. Comp.
F - G 1071 -3415
G - H 869 -2283
H - I 860 -2356
I - J 927 -2654
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 2348 -694
Q - P 25 -10
O - M 3013 -575
Chords Tens. Comp.
N - L 6 -2
L - J 2295 -693
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 436 -1221
C - O 1669 -394
Q - O 2636 -775
E - O 295 -390
O - P 77 0
O - F 1476 -710
Webs Tens. Comp.
F - M 1991 -413
M - N 99 0
M - G 886 -183
M - L 2421 -645
G - L 310 -930
L - I 190 -295
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.361 O 999 360
VERT(CL): 0.680 O 665 240
HORZ(LL): 0.219 L - -
HORZ(TL): 0.414 L - -
Creep Factor: 2.0
Max TC CSI: 0.620
Max BC CSI: 0.988
Max Web CSI: 0.962
Wgt: 222.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A02
Truss Type
COMN
Qty
3
Ply
1 2994
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
11'10"10 7'2"12 18'10"101'5"9 1'5"9
4"32'9"124'7"79'10"310'5"15(a)
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
PQ
6
12
3
123X6(A1)
4X4
3X10
3X6
1.5X3
5X8
1.5X4
5X10
6X8
2X4
3X4
6X8
3X6
1.5X3
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T2 2x4 SP M-30;
Bot chord 2x4 SP #2 B4 2x4 SP M-30;
Webs 2x4 SP #3 W3 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 95 0.15 11.74
BC 92 11.71 19.13
BC 114 19.26 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1540 /- /- /874 /408 /314
J 1539 /- /- /873 /408 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
J Brg Width = 8.0 Min Req = 1.8
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 908 -2711
C - D 1448 -4534
D - E 1460 -4453
E - F 1628 -4577
Chords Tens. Comp.
F - G 1071 -3415
G - H 869 -2283
H - I 860 -2356
I - J 927 -2654
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 2348 -694
Q - P 25 -10
O - M 3013 -575
Chords Tens. Comp.
N - L 6 -2
L - J 2295 -693
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 436 -1221
C - O 1669 -394
Q - O 2636 -775
E - O 295 -390
O - P 77 0
O - F 1476 -710
Webs Tens. Comp.
F - M 1991 -413
M - N 99 0
M - G 886 -183
M - L 2421 -645
G - L 310 -930
L - I 190 -295
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.361 O 999 360
VERT(CL): 0.680 O 665 240
HORZ(LL): 0.219 L - -
HORZ(TL): 0.414 L - -
Creep Factor: 2.0
Max TC CSI: 0.620
Max BC CSI: 0.988
Max Web CSI: 0.962
Wgt: 222.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A02
Truss Type
COMN
Qty
3
Ply
1 2994
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
11'10"10 7'2"12 18'10"101'5"9 1'5"9
4"32'9"124'7"79'10"310'5"15(a)
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
PQ
6
12
3
123X6(A1)
4X4
3X10
3X6
1.5X3
5X8
1.5X4
5X10
6X8
2X4
3X4
6X8
3X6
1.5X3
3X6(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30 T3 2x4 SP #2;
Bot chord 2x4 SP M-30 B1 2x4 SP 2400f-2.0E +
SP M-31; B4 2x4 SP #2;
Webs 2x4 SP #3 W7 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
(I) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees
Rotational Tolerance, and/or zero Positioning Tolerance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.52 19.00
BC 101 19.00 27.22
BC 120 27.26 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1545 /- /- /870 /199 /314
J 1542 /- /- /875 /195 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.8
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 1541 -4761
C - D 1351 -4345
D - E 1369 -4272
E - F 1024 -3237
Chords Tens. Comp.
F - G 1015 -3268
G - H 1513 -4612
H - I 1505 -4707
I - J 902 -2723
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 4280 -1296
Q - P 3692 -977
P - O 3721 -975
Chords Tens. Comp.
O - M 4303 -1182
N - L 33 -11
L - J 2361 -688
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 293 -342
Q - E 511 -87
E - O 445 -800
F - O 2357 -597
O - G 651 -1368
Webs Tens. Comp.
G - M 421 -56
M - N 74 0
M - L 2639 -765
M - I 1829 -465
L - I 429 -1239
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.470 O 963 360
VERT(CL): 0.888 O 509 240
HORZ(LL): 0.328 L - -
HORZ(TL): 0.620 L - -
Creep Factor: 2.0
Max TC CSI: 0.687
Max BC CSI: 0.810
Max Web CSI: 0.898
Wgt: 194.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A03
Truss Type
COMN
Qty
3
Ply
1 2993
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
19'8'1"6 10'10"101'5"9 1'5"9
4"34'7"12'6"129'10"310'5"15(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
PQ
6
12
3
12
3X8(F1)
1.5X3
3X6
3X4
H0308
3X4
5X6
6X8
3X4
H0710(I)
1.5X4
3X6
3X10
4X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30 T3 2x4 SP #2;
Bot chord 2x4 SP M-30 B1 2x4 SP 2400f-2.0E +
SP M-31; B4 2x4 SP #2;
Webs 2x4 SP #3 W7 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
(I) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees
Rotational Tolerance, and/or zero Positioning Tolerance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.52 19.00
BC 101 19.00 27.22
BC 120 27.26 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1545 /- /- /870 /199 /314
J 1542 /- /- /875 /195 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.8
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 1541 -4761
C - D 1351 -4345
D - E 1369 -4272
E - F 1024 -3237
Chords Tens. Comp.
F - G 1015 -3268
G - H 1513 -4612
H - I 1505 -4707
I - J 902 -2723
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 4280 -1296
Q - P 3692 -977
P - O 3721 -975
Chords Tens. Comp.
O - M 4303 -1182
N - L 33 -11
L - J 2361 -688
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 293 -342
Q - E 511 -87
E - O 445 -800
F - O 2357 -597
O - G 651 -1368
Webs Tens. Comp.
G - M 421 -56
M - N 74 0
M - L 2639 -765
M - I 1829 -465
L - I 429 -1239
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.470 O 963 360
VERT(CL): 0.888 O 509 240
HORZ(LL): 0.328 L - -
HORZ(TL): 0.620 L - -
Creep Factor: 2.0
Max TC CSI: 0.687
Max BC CSI: 0.810
Max Web CSI: 0.898
Wgt: 194.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A03
Truss Type
COMN
Qty
3
Ply
1 2993
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
19'8'1"6 10'10"101'5"9 1'5"9
4"34'7"12'6"129'10"310'5"15(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
PQ
6
12
3
12
3X8(F1)
1.5X3
3X6
3X4
H0308
3X4
5X6
6X8
3X4
H0710(I)
1.5X4
3X6
3X10
4X4
3X6(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30
Bot chord 2x4 :SP 2400f-2.0E + SP M-31:
B2 2x4 SP M-30;
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.52 19.00
BC 120 19.00 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1546 /- /- /870 /199 /314
J 1546 /- /- /870 /199 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.5
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 1534 -4756
C - D 1349 -4346
D - E 1366 -4270
E - F 1014 -3228
Chords Tens. Comp.
F - G 1021 -3228
G - H 1360 -4270
H - I 1343 -4346
I - J 1529 -4756
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - P 4275 -1290
P - O 3714 -981
O - N 3733 -973
Chords Tens. Comp.
N - M 3733 -961
M - L 3714 -969
L - J 4275 -1278
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - P 288 -334
P - E 508 -78
E - N 463 -829
F - N 2437 -645
Webs Tens. Comp.
N - G 463 -829
G - L 508 -76
L - I 288 -334
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.520 N 870 360
VERT(CL): 0.984 N 459 240
HORZ(LL): 0.373 L - -
HORZ(TL): 0.707 L - -
Creep Factor: 2.0
Max TC CSI: 0.680
Max BC CSI: 0.804
Max Web CSI: 0.929
Wgt: 175.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A04
Truss Type
COMN
Qty
10
Ply
1 2992
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
19'19'1'5"9 1'5"9
4"34'7"19'10"310'5"15A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
6
12
3
12
3X8(F1)
1.5X3
3X6
3X4
3X4
H0308
5X6
6X8
H0308
3X4
3X4
3X6
1.5X3
3X8(F1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30
Bot chord 2x4 :SP 2400f-2.0E + SP M-31:
B2 2x4 SP M-30;
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.52 19.00
BC 120 19.00 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1546 /- /- /870 /199 /314
J 1546 /- /- /870 /199 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.5
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 1534 -4756
C - D 1349 -4346
D - E 1366 -4270
E - F 1014 -3228
Chords Tens. Comp.
F - G 1021 -3228
G - H 1360 -4270
H - I 1343 -4346
I - J 1529 -4756
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - P 4275 -1290
P - O 3714 -981
O - N 3733 -973
Chords Tens. Comp.
N - M 3733 -961
M - L 3714 -969
L - J 4275 -1278
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - P 288 -334
P - E 508 -78
E - N 463 -829
F - N 2437 -645
Webs Tens. Comp.
N - G 463 -829
G - L 508 -76
L - I 288 -334
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.520 N 870 360
VERT(CL): 0.984 N 459 240
HORZ(LL): 0.373 L - -
HORZ(TL): 0.707 L - -
Creep Factor: 2.0
Max TC CSI: 0.680
Max BC CSI: 0.804
Max Web CSI: 0.929
Wgt: 175.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A04
Truss Type
COMN
Qty
10
Ply
1 2992
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
19'19'1'5"9 1'5"9
4"34'7"19'10"310'5"15A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
6
12
3
12
3X8(F1)
1.5X3
3X6
3X4
3X4
H0308
5X6
6X8
H0308
3X4
3X4
3X6
1.5X3
3X8(F1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T3 2x4 SP M-30;
Bot chord 2x4 SP M-30 B2 2x4 SP #2;
Webs 2x4 SP #3 W5 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 23.07
BC 90 23.10 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /873 /408 /314
K 1543 /- /- /868 /411 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.7
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 930 -2684
C - D 875 -2412
D - E 893 -2339
E - F 756 -1703
F - G 1358 -3860
Chords Tens. Comp.
G - H 1263 -3878
H - I 1558 -4494
I - J 1542 -4503
J - K 1443 -4622
K - L 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - R 2325 -707
R - Q 1899 -503
Q - P 1899 -503
Chords Tens. Comp.
P - O 17 -5
N - M 3846 -979
M - K 4136 -1176
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - R 242 -355
R - E 488 -100
E - P 351 -657
F - P 53 -714
F - N 3419 -949
P - N 1927 -343
Webs Tens. Comp.
N - O 27 0
N - G 183 -150
N - H 197 -362
H - M 454 -283
M - J 279 -333
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.437 G 999 360
VERT(CL): 0.826 G 547 240
HORZ(LL): 0.258 M - -
HORZ(TL): 0.487 M - -
Creep Factor: 2.0
Max TC CSI: 0.806
Max BC CSI: 0.997
Max Web CSI: 0.808
Wgt: 215.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A05
Truss Type
COMN
Qty
1
Ply
1 2991
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
23'2"9 14'9"71'5"9 1'5"9
4"33'6"79'10"310'5"15(a)
(a)
A
B
C
D
E
F
G
H
I J
K
L
M
N
OPQR
6
12
3
12
3X6(A1)
1.5X3
3X6
3X4 3X6
3X4
6X10
5X8
8X10
1.5X3
1.5X3
3X4
3X6
3X4
1.5X3
3X8(F1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T3 2x4 SP M-30;
Bot chord 2x4 SP M-30 B2 2x4 SP #2;
Webs 2x4 SP #3 W5 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 23.07
BC 90 23.10 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /873 /408 /314
K 1543 /- /- /868 /411 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.7
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 930 -2684
C - D 875 -2412
D - E 893 -2339
E - F 756 -1703
F - G 1358 -3860
Chords Tens. Comp.
G - H 1263 -3878
H - I 1558 -4494
I - J 1542 -4503
J - K 1443 -4622
K - L 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - R 2325 -707
R - Q 1899 -503
Q - P 1899 -503
Chords Tens. Comp.
P - O 17 -5
N - M 3846 -979
M - K 4136 -1176
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - R 242 -355
R - E 488 -100
E - P 351 -657
F - P 53 -714
F - N 3419 -949
P - N 1927 -343
Webs Tens. Comp.
N - O 27 0
N - G 183 -150
N - H 197 -362
H - M 454 -283
M - J 279 -333
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.437 G 999 360
VERT(CL): 0.826 G 547 240
HORZ(LL): 0.258 M - -
HORZ(TL): 0.487 M - -
Creep Factor: 2.0
Max TC CSI: 0.806
Max BC CSI: 0.997
Max Web CSI: 0.808
Wgt: 215.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A05
Truss Type
COMN
Qty
1
Ply
1 2991
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
23'2"9 14'9"71'5"9 1'5"9
4"33'6"79'10"310'5"15(a)
(a)
A
B
C
D
E
F
G
H
I J
K
L
M
N
OPQR
6
12
3
12
3X6(A1)
1.5X3
3X6
3X4 3X6
3X4
6X10
5X8
8X10
1.5X3
1.5X3
3X4
3X6
3X4
1.5X3
3X8(F1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T3 2x4 SP M-30;
Bot chord 2x4 SP #2 B4 2x4 SP 2400f-2.0E +
SP M-31;
Webs 2x4 SP #3 W8,W9 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 80 0.15 11.49
BC 75 11.50 23.07
BC 25 20.97 23.07
BC 83 23.07 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /873 /554 /314
K 1543 /- /- /868 /557 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.5
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 946 -2668
C - D 995 -2643
D - E 1006 -2585
E - F 766 -1841
F - G 810 -1740
Chords Tens. Comp.
G - H 1290 -3887
H - I 1635 -4483
I - J 1626 -4530
J - K 1545 -4661
K - L 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 2299 -714
V - U 73 -34
T - S 2319 -650
S - Q 1 -5
Chords Tens. Comp.
R - P 2 -7
Q - O 8 -6
N - M 4026 -1148
M - K 4173 -1278
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - V 176 -343
C - T 78 -40
V - T 2260 -689
T - U 52 0
T - E 523 -142
E - S 442 -926
F - S 1177 -494
S - G 710 -2293
S - N 2676 -570
Webs Tens. Comp.
R - Q 37 0
G - N 3255 -839
N - O 25 0
N - H 346 -558
O - P 34 0
W - N 0 0
H - M 376 -180
M - J 216 -234
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.451 N 999 360
VERT(CL): 0.852 N 531 240
HORZ(LL): 0.268 M - -
HORZ(TL): 0.507 M - -
Creep Factor: 2.0
Max TC CSI: 0.858
Max BC CSI: 0.993
Max Web CSI: 0.861
Wgt: 239.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A06
Truss Type
COMN
Qty
3
Ply
1 2990
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
11'7"9 9'4"1 2'2"15 14'9"71'5"9 1'5"9
4"38"3'6"79'10"310'5"15(a)
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
OPQRS
TUV
W
6
12
3
12
3X6(A1)
3X4
4X8(R)
3X6
5X8
3X4
5X6
7X10
7X6
10X10
3X3
3X4
3X6
3X4
3X8(F1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T3 2x4 SP M-30;
Bot chord 2x4 SP #2 B4 2x4 SP 2400f-2.0E +
SP M-31;
Webs 2x4 SP #3 W8,W9 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 80 0.15 11.49
BC 75 11.50 23.07
BC 25 20.97 23.07
BC 83 23.07 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /873 /554 /314
K 1543 /- /- /868 /557 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.5
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 946 -2668
C - D 995 -2643
D - E 1006 -2585
E - F 766 -1841
F - G 810 -1740
Chords Tens. Comp.
G - H 1290 -3887
H - I 1635 -4483
I - J 1626 -4530
J - K 1545 -4661
K - L 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 2299 -714
V - U 73 -34
T - S 2319 -650
S - Q 1 -5
Chords Tens. Comp.
R - P 2 -7
Q - O 8 -6
N - M 4026 -1148
M - K 4173 -1278
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - V 176 -343
C - T 78 -40
V - T 2260 -689
T - U 52 0
T - E 523 -142
E - S 442 -926
F - S 1177 -494
S - G 710 -2293
S - N 2676 -570
Webs Tens. Comp.
R - Q 37 0
G - N 3255 -839
N - O 25 0
N - H 346 -558
O - P 34 0
W - N 0 0
H - M 376 -180
M - J 216 -234
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.451 N 999 360
VERT(CL): 0.852 N 531 240
HORZ(LL): 0.268 M - -
HORZ(TL): 0.507 M - -
Creep Factor: 2.0
Max TC CSI: 0.858
Max BC CSI: 0.993
Max Web CSI: 0.861
Wgt: 239.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A06
Truss Type
COMN
Qty
3
Ply
1 2990
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
19'19'
11'7"9 9'4"1 2'2"15 14'9"71'5"9 1'5"9
4"38"3'6"79'10"310'5"15(a)
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
OPQRS
TUV
W
6
12
3
12
3X6(A1)
3X4
4X8(R)
3X6
5X8
3X4
5X6
7X10
7X6
10X10
3X3
3X4
3X6
3X4
3X8(F1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T4,T5 2x4 SP M-30;
Bot chord 2x4 SP #2 B4 2x4 SP 2400f-2.0E +
SP M-31;
Webs 2x4 SP #3 W8 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 17.99 20.01
BC 81 0.15 11.49
BC 89 11.50 23.12
BC 26 20.97 23.11
BC 81 23.14 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /875 /556 /299
K 1543 /- /- /870 /559 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.5
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 969 -2712
C - D 1014 -2650
D - E 1030 -2587
E - F 856 -1920
F - G 820 -1613
Chords Tens. Comp.
G - H 1544 -3972
H - I 1395 -3975
I - J 1367 -4015
J - K 1595 -4710
K - L 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - W 2350 -757
W - V 98 -36
U - T 2315 -700
T - S 1634 -383
S - Q 25 -8
Chords Tens. Comp.
R - P 2 -14
Q - O 38 -11
N - M 4273 -1350
M - K 4224 -1329
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - W 169 -285
C - U 103 -101
W - U 2273 -726
U - V 79 0
U - E 493 -126
E - T 415 -872
F - T 563 -184
F - S 166 -240
S - G 343 -1375
Webs Tens. Comp.
S - N 2206 -495
G - N 3625 -1135
R - Q 36 0
O - P 39 0
N - O 49 0
N - H 312 -396
N - J 409 -749
J - M 136 -81
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.434 H 999 360
VERT(CL): 0.819 H 552 240
HORZ(LL): 0.269 M - -
HORZ(TL): 0.508 M - -
Creep Factor: 2.0
Max TC CSI: 0.642
Max BC CSI: 0.978
Max Web CSI: 0.866
Wgt: 254.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A07
Truss Type
COMN
Qty
1
Ply
1 2989
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
17'11"15 2'0"2 17'11"15
11'7"9 9'4"1 2'3"7 14'8"151'5"9 1'5"9
4"38"3'6"59'4"29'11"14(a)
(a)
(a)
A
B
C
D
E
F G
H
I
J
K
L
M
N
OPQRST
UVW
6
12
3
12
3X6(A1)
3X4
4X8(R)
3X6
5X8
1.5X4
3X4
5X8
3X4 6X8
7X6
10X10
3X3
3X6
3X4
3X8(F1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T4,T5 2x4 SP M-30;
Bot chord 2x4 SP #2 B4 2x4 SP 2400f-2.0E +
SP M-31;
Webs 2x4 SP #3 W8 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 17.99 20.01
BC 81 0.15 11.49
BC 89 11.50 23.12
BC 26 20.97 23.11
BC 81 23.14 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /875 /556 /299
K 1543 /- /- /870 /559 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.5
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 969 -2712
C - D 1014 -2650
D - E 1030 -2587
E - F 856 -1920
F - G 820 -1613
Chords Tens. Comp.
G - H 1544 -3972
H - I 1395 -3975
I - J 1367 -4015
J - K 1595 -4710
K - L 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - W 2350 -757
W - V 98 -36
U - T 2315 -700
T - S 1634 -383
S - Q 25 -8
Chords Tens. Comp.
R - P 2 -14
Q - O 38 -11
N - M 4273 -1350
M - K 4224 -1329
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - W 169 -285
C - U 103 -101
W - U 2273 -726
U - V 79 0
U - E 493 -126
E - T 415 -872
F - T 563 -184
F - S 166 -240
S - G 343 -1375
Webs Tens. Comp.
S - N 2206 -495
G - N 3625 -1135
R - Q 36 0
O - P 39 0
N - O 49 0
N - H 312 -396
N - J 409 -749
J - M 136 -81
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.434 H 999 360
VERT(CL): 0.819 H 552 240
HORZ(LL): 0.269 M - -
HORZ(TL): 0.508 M - -
Creep Factor: 2.0
Max TC CSI: 0.642
Max BC CSI: 0.978
Max Web CSI: 0.866
Wgt: 254.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A07
Truss Type
COMN
Qty
1
Ply
1 2989
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
17'11"15 2'0"2 17'11"15
11'7"9 9'4"1 2'3"7 14'8"151'5"9 1'5"9
4"38"3'6"59'4"29'11"14(a)
(a)
(a)
A
B
C
D
E
F G
H
I
J
K
L
M
N
OPQRST
UVW
6
12
3
12
3X6(A1)
3X4
4X8(R)
3X6
5X8
1.5X4
3X4
5X8
3X4 6X8
7X6
10X10
3X3
3X6
3X4
3X8(F1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T4 2x4 SP M-30;
T5 2x4 SP 2400f-2.0E + SP M-31;
Bot chord 2x4 SP #2 B4,B5 2x4 SP 2400f-2.0E +
SP M-31;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 15.99 22.01
BC 81 0.15 11.49
BC 90 11.50 23.24
BC 27 20.97 23.26
BC 80 21.93 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /877 /558 /271
J 1543 /- /- /872 /561 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
J Brg Width = 8.0 Min Req = 1.5
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 1104 -2716
C - D 1167 -2640
D - E 1179 -2552
E - F 1046 -2078
Chords Tens. Comp.
F - G 1483 -3292
G - H 1545 -3633
H - I 1530 -3779
I - J 1834 -4681
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - X 2355 -878
X - W 108 -39
V - U 2299 -828
U - S 46 -19
T - N 29 -71
S - R 117 -48
Chords Tens. Comp.
Q - O 4237 -1559
R - P 109 -47
O - M 4237 -1566
M - L 4219 -1570
L - J 4198 -1548
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - X 191 -285
C - V 117 -126
X - V 2268 -845
V - W 80 0
V - E 495 -143
E - U 359 -751
F - U 122 -399
F - Q 1811 -629
Webs Tens. Comp.
U - Q 2019 -658
T - S 35 0
Q - R 139 -125
Q - G 1156 -334
Q - I 524 -959
P - O 149 -87
P - N 54 -5
I - L 163 -55
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.406 S 999 360
VERT(CL): 0.766 S 590 240
HORZ(LL): 0.253 L - -
HORZ(TL): 0.477 L - -
Creep Factor: 2.0
Max TC CSI: 0.853
Max BC CSI: 0.974
Max Web CSI: 0.864
Wgt: 232.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A08
Truss Type
COMN
Qty
1
Ply
1 2988
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
15'11"15 6'0"2 15'11"15
11'7"9 9'4"1 2'3"7 14'8"151'5"9 1'5"9
4"38"3'10"18'4"28'11"14(a)
A
B
C
D
E
F G
H
I
J
K
L
M
N
O
P
Q
RSTU
VWX
6
12
3
12
3X6(A1)
3X4
4X8(R)
3X6
5X8
1.5X4
3X4
5X8
4X10
7X10
5X6
3X3
4X6
H0308
3X4
3X8(F1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2 T4 2x4 SP M-30;
T5 2x4 SP 2400f-2.0E + SP M-31;
Bot chord 2x4 SP #2 B4,B5 2x4 SP 2400f-2.0E +
SP M-31;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 15.99 22.01
BC 81 0.15 11.49
BC 90 11.50 23.24
BC 27 20.97 23.26
BC 80 21.93 37.48
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1539 /- /- /877 /558 /271
J 1543 /- /- /872 /561 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
J Brg Width = 8.0 Min Req = 1.5
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 1104 -2716
C - D 1167 -2640
D - E 1179 -2552
E - F 1046 -2078
Chords Tens. Comp.
F - G 1483 -3292
G - H 1545 -3633
H - I 1530 -3779
I - J 1834 -4681
J - K 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - X 2355 -878
X - W 108 -39
V - U 2299 -828
U - S 46 -19
T - N 29 -71
S - R 117 -48
Chords Tens. Comp.
Q - O 4237 -1559
R - P 109 -47
O - M 4237 -1566
M - L 4219 -1570
L - J 4198 -1548
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - X 191 -285
C - V 117 -126
X - V 2268 -845
V - W 80 0
V - E 495 -143
E - U 359 -751
F - U 122 -399
F - Q 1811 -629
Webs Tens. Comp.
U - Q 2019 -658
T - S 35 0
Q - R 139 -125
Q - G 1156 -334
Q - I 524 -959
P - O 149 -87
P - N 54 -5
I - L 163 -55
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.406 S 999 360
VERT(CL): 0.766 S 590 240
HORZ(LL): 0.253 L - -
HORZ(TL): 0.477 L - -
Creep Factor: 2.0
Max TC CSI: 0.853
Max BC CSI: 0.974
Max Web CSI: 0.864
Wgt: 232.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A08
Truss Type
COMN
Qty
1
Ply
1 2988
03/19/2021
38'
SEAT PLATE REQ.SEAT PLATE REQ.
15'11"15 6'0"2 15'11"15
11'7"9 9'4"1 2'3"7 14'8"151'5"9 1'5"9
4"38"3'10"18'4"28'11"14(a)
A
B
C
D
E
F G
H
I
J
K
L
M
N
O
P
Q
RSTU
VWX
6
12
3
12
3X6(A1)
3X4
4X8(R)
3X6
5X8
1.5X4
3X4
5X8
4X10
7X10
5X6
3X3
4X6
H0308
3X4
3X8(F1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30 T3 2x4 SP 2400f-2.0E +
SP M-31; T4,T5 2x4 SP #2;
Bot chord 2x4 SP #2 B2 2x4 SP M-30;
Webs 2x4 SP #3 W9 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 13.99 24.01
BC 75 0.15 11.49
BC 116 11.48 21.11
BC 75 21.11 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed
8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or
notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1874 /- /- /933 /734 /484
AF*342 /- /- /114 /121 /-
Q 244 /- /- /309 /109 /-
U /-353
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.2
AF Brg Width = 171 Min Req = -
Q Brg Width = 8.0 Min Req = 1.5
Bearings B, AF, & Q are a rigid surface.
Bearings B, AF, & Q require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 82 0
B - C 1728 -2899
C - D 1438 -2226
D - E 1477 -2128
E - F 1757 -2074
F - G 418 -136
G - H 418 -135
H - I 418 -135
I - J 1291 -260
Chords Tens. Comp.
J - K 1295 -340
K - L 1328 -506
L - M 1268 -590
M - N 1182 -594
N - O 517 -78
O - P 484 -174
P - Q 480 -310
Q - R 82 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AD 2440 -1319
AD-AC 81 -70
AB- Z 1316 -341
AA- Y 5 -84
Y - X 510 -390
X - W 510 -390
Chords Tens. Comp.
W - V 510 -390
V - U 510 -390
U - T 502 -382
T - S 495 -374
S - Q 483 -360
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C -AD 242 -331
C -AB 667 -689
AD-AB 2381 -1259
E -AB 575 -522
AB-AC 73 0
AB- F 1311 -1039
F - Z 1280 -1955
G - Z 795 -1211
Z -AA 29 -19
Z -AE 2411 -1339
Webs Tens. Comp.
Z -AF 1255 -1216
AF- Y 1262 -1236
AG- I 2349 -1303
Y - I 1391 -2822
Y -AH 766 -870
AH-AI 702 -771
AJ-AK 739 -830
AL- N 715 -796
N - U 367 -363
Maximum Gable Forces Per Ply (lbs)
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.090 E 999 360
VERT(CL): 0.194 E 999 240
HORZ(LL): 0.038 Y - -
HORZ(TL): 0.082 Y - -
Creep Factor: 2.0
Max TC CSI: 0.817
Max BC CSI: 0.850
Max Web CSI: 0.986
Wgt: 268.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A09
Truss Type
GABL
Qty
1
Ply
1 2987
03/19/2021
23'14'4"8"SEAT PLATE REQ.SEAT PLATE REQ. SEAT PLATE REQ.
13'11"15 10'0"2 13'11"15
11'7"9 9'4"1 17'0"61'5"9 1'5"9
38'
4"38"7'4"27'11"14(a)
(a)(a)
(a)(a)
A
B
C D
E
F G H I
J
K
L
MN
O
P
Q
R
STUVWXY
Z AAABACAD
AE
AF
AG
AH
AI
AJ AK
AL
6
12
4X6(A2)
3X4
5X8(R)
3X6
6X8
1.5X4
H0710 1.5X4
7X8
5X8
6X8
2X4 3X6
3X6
3X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30 T3 2x4 SP 2400f-2.0E +
SP M-31; T4,T5 2x4 SP #2;
Bot chord 2x4 SP #2 B2 2x4 SP M-30;
Webs 2x4 SP #3 W9 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 13.99 24.01
BC 75 0.15 11.49
BC 116 11.48 21.11
BC 75 21.11 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed
8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or
notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1874 /- /- /933 /734 /484
AF*342 /- /- /114 /121 /-
Q 244 /- /- /309 /109 /-
U /-353
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.2
AF Brg Width = 171 Min Req = -
Q Brg Width = 8.0 Min Req = 1.5
Bearings B, AF, & Q are a rigid surface.
Bearings B, AF, & Q require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 82 0
B - C 1728 -2899
C - D 1438 -2226
D - E 1477 -2128
E - F 1757 -2074
F - G 418 -136
G - H 418 -135
H - I 418 -135
I - J 1291 -260
Chords Tens. Comp.
J - K 1295 -340
K - L 1328 -506
L - M 1268 -590
M - N 1182 -594
N - O 517 -78
O - P 484 -174
P - Q 480 -310
Q - R 82 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AD 2440 -1319
AD-AC 81 -70
AB- Z 1316 -341
AA- Y 5 -84
Y - X 510 -390
X - W 510 -390
Chords Tens. Comp.
W - V 510 -390
V - U 510 -390
U - T 502 -382
T - S 495 -374
S - Q 483 -360
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C -AD 242 -331
C -AB 667 -689
AD-AB 2381 -1259
E -AB 575 -522
AB-AC 73 0
AB- F 1311 -1039
F - Z 1280 -1955
G - Z 795 -1211
Z -AA 29 -19
Z -AE 2411 -1339
Webs Tens. Comp.
Z -AF 1255 -1216
AF- Y 1262 -1236
AG- I 2349 -1303
Y - I 1391 -2822
Y -AH 766 -870
AH-AI 702 -771
AJ-AK 739 -830
AL- N 715 -796
N - U 367 -363
Maximum Gable Forces Per Ply (lbs)
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.090 E 999 360
VERT(CL): 0.194 E 999 240
HORZ(LL): 0.038 Y - -
HORZ(TL): 0.082 Y - -
Creep Factor: 2.0
Max TC CSI: 0.817
Max BC CSI: 0.850
Max Web CSI: 0.986
Wgt: 268.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A09
Truss Type
GABL
Qty
1
Ply
1 2987
03/19/2021
23'14'4"8"SEAT PLATE REQ.SEAT PLATE REQ. SEAT PLATE REQ.
13'11"15 10'0"2 13'11"15
11'7"9 9'4"1 17'0"61'5"9 1'5"9
38'
4"38"7'4"27'11"14(a)
(a)(a)
(a)(a)
A
B
C D
E
F G H I
J
K
L
MN
O
P
Q
R
STUVWXY
Z AAABACAD
AE
AF
AG
AH
AI
AJ AK
AL
6
12
4X6(A2)
3X4
5X8(R)
3X6
6X8
1.5X4
H0710 1.5X4
7X8
5X8
6X8
2X4 3X6
3X6
3X4
3X6(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
Gables Tens.Comp.
AE-AF 25 -73
H -AG 7 -24
J -AH 183 -208
AI- X 604 -589
K -AJ 485 -452
Gables Tens. Comp.
AK- W 138 -175
L -AL 176 -231
T - O 280 -328
S - P 286 -319
Truss
A09
Truss Type
GABL
Qty
1
Ply
1 2987
03/19/2021
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 B2 2x4 SP M-30;
Webs 2x4 SP #3 W5 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 12.99 25.00
BC 79 0.15 23.67
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical exposed to wind pressure. Deflection meets L/360.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 997 /- /- /617 /389 /369
M 980 /- /- /486 /484 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
M Brg Width = 8.0 Min Req = 1.5
Bearings B & M are a rigid surface.
Bearings B & M require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 985 -1530
C - D 763 -1015
D - E 790 -995
Chords Tens. Comp.
E - F 783 -827
F - G 210 -159
G - H 0 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - L 1295 -1307
L - K 1293 -1308
Chords Tens. Comp.
K - J 1293 -1308
J - I 563 -697
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
L - C 174 0
C - J 456 -534
E - J 199 0
Webs Tens. Comp.
J - F 427 -336
F - I 931 -892
G - I 295 -228
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.046 L 999 360
VERT(CL): 0.087 L 999 240
HORZ(LL): 0.018 I - -
HORZ(TL): 0.034 I - -
Creep Factor: 2.0
Max TC CSI: 0.446
Max BC CSI: 0.969
Max Web CSI: 0.850
Wgt: 140.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A10
Truss Type
COMN
Qty
1
Ply
1 3339
03/19/2021
23'8"
SEAT PLATE REQ.SEAT PLATE REQ.
12'11"15 10'8"1
1'5"9 1'4"
4"3 6'10"27'5"14(a)
A
B
C D
E F G H
IJKL M
6
12
3X4(A1)
1.5X3
3X4
3X6
4X6
5X6
3X8
3X4 1.5X3
3X6(R)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 B2 2x4 SP M-30;
Webs 2x4 SP #3 W5 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 12.99 25.00
BC 79 0.15 23.67
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical exposed to wind pressure. Deflection meets L/360.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 997 /- /- /617 /389 /369
M 980 /- /- /486 /484 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
M Brg Width = 8.0 Min Req = 1.5
Bearings B & M are a rigid surface.
Bearings B & M require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 985 -1530
C - D 763 -1015
D - E 790 -995
Chords Tens. Comp.
E - F 783 -827
F - G 210 -159
G - H 0 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - L 1295 -1307
L - K 1293 -1308
Chords Tens. Comp.
K - J 1293 -1308
J - I 563 -697
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
L - C 174 0
C - J 456 -534
E - J 199 0
Webs Tens. Comp.
J - F 427 -336
F - I 931 -892
G - I 295 -228
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.046 L 999 360
VERT(CL): 0.087 L 999 240
HORZ(LL): 0.018 I - -
HORZ(TL): 0.034 I - -
Creep Factor: 2.0
Max TC CSI: 0.446
Max BC CSI: 0.969
Max Web CSI: 0.850
Wgt: 140.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A10
Truss Type
COMN
Qty
1
Ply
1 3339
03/19/2021
23'8"
SEAT PLATE REQ.SEAT PLATE REQ.
12'11"15 10'8"1
1'5"9 1'4"
4"3 6'10"27'5"14(a)
A
B
C D
E F G H
IJKL M
6
12
3X4(A1)
1.5X3
3X4
3X6
4X6
5X6
3X8
3X4 1.5X3
3X6(R)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.99 25.00
BC 75 0.15 23.67
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical exposed to wind pressure. Deflection meets L/360.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
P* 84 /- /- /46 /37 /13
Wind reactions based on MWFRS
P Brg Width = 284 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 66 -443
C - D 43 -345
D - E 90 -301
E - F 153 -244
F - G 190 -150
G - H 188 -134
Chords Tens. Comp.
H - I 188 -133
I - J 188 -133
J - K 188 -133
K - L 188 -133
L - M 188 -133
M - N 188 -133
N - O 0 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AB 494 -86
AB-AA 501 -88
AA- Z 503 -89
Z - Y 173 -145
Y - X 175 -143
X - W 176 -141
W - V 176 -141
Chords Tens. Comp.
V - U 176 -141
U - T 176 -141
T - S 176 -141
S - R 176 -141
R - Q 176 -141
Q - P 176 -141
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C -AB 197 -181
D -AA 112 -105
E - Y 151 -126
F - X 222 -125
H - W 206 -127
I - V 173 -123
Gables Tens. Comp.
J - U 162 -125
K - S 160 -124
L - R 169 -129
M - Q 117 -80
N - P 259 -176
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.002 G 999 360
VERT(CL): 0.003 AB 999 240
HORZ(LL): -0.007 G - -
HORZ(TL): 0.008 G - -
Creep Factor: 2.0
Max TC CSI: 0.196
Max BC CSI: 0.102
Max Web CSI: 0.693
Wgt: 154.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A11
Truss Type
GABL
Qty
1
Ply
1 3342
03/19/2021
23'8"
SEAT PLATE REQ.
10'11"15 12'8"1
1'5"9 1'4"
4"3 5'10"26'5"14A
B
C
D
E
F
G H I J K L M N O
P
QRSTUVWXYZAAAB
6
12
2X4(A1)
3X6
5X6
3X6
3X6
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.99 25.00
BC 75 0.15 23.67
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical exposed to wind pressure. Deflection meets L/360.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
P* 84 /- /- /46 /37 /13
Wind reactions based on MWFRS
P Brg Width = 284 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 66 -443
C - D 43 -345
D - E 90 -301
E - F 153 -244
F - G 190 -150
G - H 188 -134
Chords Tens. Comp.
H - I 188 -133
I - J 188 -133
J - K 188 -133
K - L 188 -133
L - M 188 -133
M - N 188 -133
N - O 0 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AB 494 -86
AB-AA 501 -88
AA- Z 503 -89
Z - Y 173 -145
Y - X 175 -143
X - W 176 -141
W - V 176 -141
Chords Tens. Comp.
V - U 176 -141
U - T 176 -141
T - S 176 -141
S - R 176 -141
R - Q 176 -141
Q - P 176 -141
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C -AB 197 -181
D -AA 112 -105
E - Y 151 -126
F - X 222 -125
H - W 206 -127
I - V 173 -123
Gables Tens. Comp.
J - U 162 -125
K - S 160 -124
L - R 169 -129
M - Q 117 -80
N - P 259 -176
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.002 G 999 360
VERT(CL): 0.003 AB 999 240
HORZ(LL): -0.007 G - -
HORZ(TL): 0.008 G - -
Creep Factor: 2.0
Max TC CSI: 0.196
Max BC CSI: 0.102
Max Web CSI: 0.693
Wgt: 154.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
A11
Truss Type
GABL
Qty
1
Ply
1 3342
03/19/2021
23'8"
SEAT PLATE REQ.
10'11"15 12'8"1
1'5"9 1'4"
4"3 5'10"26'5"14A
B
C
D
E
F
G H I J K L M N O
P
QRSTUVWXYZAAAB
6
12
2X4(A1)
3X6
5X6
3X6
3X6
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 12.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 91 /- /- /42 /40 /10
Wind reactions based on MWFRS
H Brg Width = 147 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 17 -29
C - D 59 -19
D - E 162 -25
Chords Tens. Comp.
E - F 160 -37
F - G 70 -54
G - H 59 -66
H - I 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 148 -41
N - M 155 -43
M - L 162 -46
Chords Tens. Comp.
L - K 162 -46
K - J 155 -45
J - H 147 -45
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
E - L 2 -112
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 140 -91
D - M 226 -145
Gables Tens. Comp.
K - F 226 -145
J - G 140 -91
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.001 N 999 360
VERT(CL): 0.001 N 999 240
HORZ(LL): -0.001 N - -
HORZ(TL): 0.001 N - -
Creep Factor: 2.0
Max TC CSI: 0.188
Max BC CSI: 0.038
Max Web CSI: 0.052
Wgt: 60.2 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B01
Truss Type
GABL
Qty
1
Ply
1 2984
03/19/2021
12'4"
SEAT PLATE REQ.
6'2"6'2"
1'5"9 1'5"9
4"33'5"34'0"15A
B
C
D
E
F
G
H
I
JKLMN
6
12
2X4(A1)
4X4
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 12.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 91 /- /- /42 /40 /10
Wind reactions based on MWFRS
H Brg Width = 147 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 17 -29
C - D 59 -19
D - E 162 -25
Chords Tens. Comp.
E - F 160 -37
F - G 70 -54
G - H 59 -66
H - I 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 148 -41
N - M 155 -43
M - L 162 -46
Chords Tens. Comp.
L - K 162 -46
K - J 155 -45
J - H 147 -45
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
E - L 2 -112
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 140 -91
D - M 226 -145
Gables Tens. Comp.
K - F 226 -145
J - G 140 -91
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.001 N 999 360
VERT(CL): 0.001 N 999 240
HORZ(LL): -0.001 N - -
HORZ(TL): 0.001 N - -
Creep Factor: 2.0
Max TC CSI: 0.188
Max BC CSI: 0.038
Max Web CSI: 0.052
Wgt: 60.2 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B01
Truss Type
GABL
Qty
1
Ply
1 2984
03/19/2021
12'4"
SEAT PLATE REQ.
6'2"6'2"
1'5"9 1'5"9
4"33'5"34'0"15A
B
C
D
E
F
G
H
I
JKLMN
6
12
2X4(A1)
4X4
2X4(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 12.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 558 /- /- /335 /246 /123
D 558 /- /- /335 /246 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 8.0 Min Req = 1.5
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 505 -629
Chords Tens. Comp.
C - D 505 -629
D - E 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - F 497 -240
Chords Tens. Comp.
F - D 497 -240
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - F 231 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.010 F 999 360
VERT(CL): 0.018 F 999 240
HORZ(LL): 0.005 F - -
HORZ(TL): 0.009 F - -
Creep Factor: 2.0
Max TC CSI: 0.398
Max BC CSI: 0.329
Max Web CSI: 0.088
Wgt: 51.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B02
Truss Type
COMN
Qty
3
Ply
1 2983
03/19/2021
12'4"
SEAT PLATE REQ.SEAT PLATE REQ.
6'2"6'2"
1'5"9 1'5"9
4"33'5"34'0"15A
B
C
D
EF
6
12
2X4(A1)
4X4
1.5X3
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 12.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 558 /- /- /335 /246 /123
D 558 /- /- /335 /246 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 8.0 Min Req = 1.5
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 505 -629
Chords Tens. Comp.
C - D 505 -629
D - E 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - F 497 -240
Chords Tens. Comp.
F - D 497 -240
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - F 231 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.010 F 999 360
VERT(CL): 0.018 F 999 240
HORZ(LL): 0.005 F - -
HORZ(TL): 0.009 F - -
Creep Factor: 2.0
Max TC CSI: 0.398
Max BC CSI: 0.329
Max Web CSI: 0.088
Wgt: 51.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B02
Truss Type
COMN
Qty
3
Ply
1 2983
03/19/2021
12'4"
SEAT PLATE REQ.SEAT PLATE REQ.
6'2"6'2"
1'5"9 1'5"9
4"33'5"34'0"15A
B
C
D
EF
6
12
2X4(A1)
4X4
1.5X3
2X4(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 553 /- /- /331 /245 /104
D 450 /- /- /237 /187 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 3.9 Min Req = 1.5
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 412 -613
Chords Tens. Comp.
C - D 417 -614
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - E 483 -274
Chords Tens. Comp.
E - D 483 -274
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - E 222 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.009 E 999 360
VERT(CL): 0.017 E 999 240
HORZ(LL): 0.004 E - -
HORZ(TL): 0.008 E - -
Creep Factor: 2.0
Max TC CSI: 0.350
Max BC CSI: 0.711
Max Web CSI: 0.085
Wgt: 44.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B03
Truss Type
SPEC
Qty
1
Ply
1 2982
03/19/2021
11'11"14
SEAT PLATE REQ.SEAT PLATE REQ.
6'2"5'9"14
1'5"9
4"3 6"43'5"34'0"15A
B
C
D
E
6
12
2X4(A1)
4X4
1.5X3
3X4(B1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 553 /- /- /331 /245 /104
D 450 /- /- /237 /187 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 3.9 Min Req = 1.5
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 412 -613
Chords Tens. Comp.
C - D 417 -614
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - E 483 -274
Chords Tens. Comp.
E - D 483 -274
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - E 222 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.009 E 999 360
VERT(CL): 0.017 E 999 240
HORZ(LL): 0.004 E - -
HORZ(TL): 0.008 E - -
Creep Factor: 2.0
Max TC CSI: 0.350
Max BC CSI: 0.711
Max Web CSI: 0.085
Wgt: 44.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B03
Truss Type
SPEC
Qty
1
Ply
1 2982
03/19/2021
11'11"14
SEAT PLATE REQ.SEAT PLATE REQ.
6'2"5'9"14
1'5"9
4"3 6"43'5"34'0"15A
B
C
D
E
6
12
2X4(A1)
4X4
1.5X3
3X4(B1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30
Bot chord 2x4 SP #2
Webs 2x4 SP #3 W2 2x4 SP #2; W3 2x6 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 74 0.15 11.99
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed
8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or
notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1151 /- /- /641 /549 /814
H 1013 /- /- /515 /710 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
H Brg Width = 3.9 Min Req = 1.5
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 82 0
B - C 290 -1288
C - D 56 -293
Chords Tens. Comp.
D - E 177 -314
E - F 266 -232
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 993 -793
Chords Tens. Comp.
I - H 992 -794
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
I - C 219 0
C - J 1005 -1244
J - K 960 -1198
Webs Tens. Comp.
K - G 1022 -1275
G - F 292 -346
G - H 769 -974
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
D - J 93 -93
Gables Tens. Comp.
E - K 159 -173
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.100 E 999 360
VERT(CL): 0.173 E 822 240
HORZ(LL): -0.054 E - -
HORZ(TL): 0.081 E - -
Creep Factor: 2.0
Max TC CSI: 0.632
Max BC CSI: 0.988
Max Web CSI: 0.911
Wgt: 74.2 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B04
Truss Type
GABL
Qty
1
Ply
1 2981
03/19/2021
11'11"14
SEAT PLATE REQ.SEAT PLATE REQ.
1'5"9
4"3 6'4"26'11"14(a)
A
B
C
D
E
F
G
HI
J
K
6
12
3X4(A1)
3X4
4X6
1.5X4
3X6
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP M-30
Bot chord 2x4 SP #2
Webs 2x4 SP #3 W2 2x4 SP #2; W3 2x6 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 74 0.15 11.99
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed
8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or
notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1151 /- /- /641 /549 /814
H 1013 /- /- /515 /710 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
H Brg Width = 3.9 Min Req = 1.5
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 82 0
B - C 290 -1288
C - D 56 -293
Chords Tens. Comp.
D - E 177 -314
E - F 266 -232
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 993 -793
Chords Tens. Comp.
I - H 992 -794
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
I - C 219 0
C - J 1005 -1244
J - K 960 -1198
Webs Tens. Comp.
K - G 1022 -1275
G - F 292 -346
G - H 769 -974
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
D - J 93 -93
Gables Tens. Comp.
E - K 159 -173
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.100 E 999 360
VERT(CL): 0.173 E 822 240
HORZ(LL): -0.054 E - -
HORZ(TL): 0.081 E - -
Creep Factor: 2.0
Max TC CSI: 0.632
Max BC CSI: 0.988
Max Web CSI: 0.911
Wgt: 74.2 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B04
Truss Type
GABL
Qty
1
Ply
1 2981
03/19/2021
11'11"14
SEAT PLATE REQ.SEAT PLATE REQ.
1'5"9
4"3 6'4"26'11"14(a)
A
B
C
D
E
F
G
HI
J
K
6
12
3X4(A1)
3X4
4X6
1.5X4
3X6
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.99
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 557 /- /- /363 /76 /242
E 446 /- /- /299 /157 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
E Brg Width = 3.9 Min Req = 1.5
Bearings B & E are a rigid surface.
Bearings B & E require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 140 -625
Chords Tens. Comp.
C - D 60 -105
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - F 496 -399
Chords Tens. Comp.
F - E 493 -401
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
F - C 238 0
C - E 461 -567
Webs Tens. Comp.
D - E 171 -135
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.011 F 999 360
VERT(CL): 0.020 F 999 240
HORZ(LL): 0.005 E - -
HORZ(TL): 0.009 E - -
Creep Factor: 2.0
Max TC CSI: 0.569
Max BC CSI: 0.417
Max Web CSI: 0.444
Wgt: 61.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B05
Truss Type
MONO
Qty
2
Ply
1 2923
03/19/2021
11'11"14
SEAT PLATE REQ.SEAT PLATE REQ.
1'5"9
4"3 6'4"26'11"14A
B
C
D
EF
6
12
2X4(A1)
1.5X3
3X4
1.5X3
3X6(R)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.99
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 557 /- /- /363 /76 /242
E 446 /- /- /299 /157 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
E Brg Width = 3.9 Min Req = 1.5
Bearings B & E are a rigid surface.
Bearings B & E require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 140 -625
Chords Tens. Comp.
C - D 60 -105
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - F 496 -399
Chords Tens. Comp.
F - E 493 -401
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
F - C 238 0
C - E 461 -567
Webs Tens. Comp.
D - E 171 -135
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.011 F 999 360
VERT(CL): 0.020 F 999 240
HORZ(LL): 0.005 E - -
HORZ(TL): 0.009 E - -
Creep Factor: 2.0
Max TC CSI: 0.569
Max BC CSI: 0.417
Max Web CSI: 0.444
Wgt: 61.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
B05
Truss Type
MONO
Qty
2
Ply
1 2923
03/19/2021
11'11"14
SEAT PLATE REQ.SEAT PLATE REQ.
1'5"9
4"3 6'4"26'11"14A
B
C
D
EF
6
12
2X4(A1)
1.5X3
3X4
1.5X3
3X6(R)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP M-30
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.46 to 62 plf at 2.03
TC: From 31 plf at 2.03 to 31 plf at 17.30
TC: From 62 plf at 17.30 to 62 plf at 20.80
BC: From 7 plf at 0.00 to 7 plf at 19.33
TC: 46 lb Conc. Load at 2.03,17.30
TC: 26 lb Conc. Load at 4.06, 6.06, 8.06, 9.67
11.27,13.27,15.27
BC: 59 lb Conc. Load at 2.03,17.30
BC: 25 lb Conc. Load at 4.06, 6.06, 8.06, 9.67
11.27,13.27,15.27
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 115 0.15 19.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed
8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or
notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1736 /- /- /- /445 /-
J 1736 /- /- /- /445 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.0
J Brg Width = 8.0 Min Req = 2.0
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 82 -25
B - C 657 -2747
C - D 534 -2385
D - E 440 -1898
E - F 506 -1835
Chords Tens. Comp.
F - G 506 -1835
G - H 440 -1898
H - I 534 -2384
I - J 657 -2747
J - K 82 -25
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - L 2350 -554
Chords Tens. Comp.
L - J 2350 -554
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - M 131 -275
D - N 213 -543
M - O 131 -274
N - O 211 -537
O - P 295 -781
P - L 428 -1112
P - Q 202 -148
F - Q 1158 -332
Webs Tens. Comp.
L - R 428 -1112
Q - L 1161 -334
Q - R 202 -148
R - S 295 -781
S - T 211 -537
S - U 131 -275
T - H 212 -542
U - I 131 -276
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
M - N 3 -13
E - P 110 -294
Gables Tens. Comp.
R - G 110 -294
T - U 3 -14
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.084 E 999 360
VERT(CL): 0.165 E 999 240
HORZ(LL): 0.031 L - -
HORZ(TL): 0.060 L - -
Creep Factor: 2.0
Max TC CSI: 0.580
Max BC CSI: 0.984
Max Web CSI: 0.618
Wgt: 124.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C01
Truss Type
GABL
Qty
1
Ply
1 2997
03/19/2021
19'4"
SEAT PLATE REQ.SEAT PLATE REQ.
9'8"9'8"
1'5"9 1'5"9
4"35'2"35'9"15A
B
C
D
E
F
G
H
I
J
KL
M
N
OP Q R S
T
U
6
12
3X6(A1)
3X6
4X4
4X6
6X6
3X6
3X6(A1)
2'0"6
59#
46#
2'0"6
25#
26#
2'
25#
26#
2'
25#
26#
1'7"4
25#
26#
1'7"4
25#
26#
2'
25#
26#
2'
25#
26#
2'0"6
59#
46#
2'0"6
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP M-30
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.46 to 62 plf at 2.03
TC: From 31 plf at 2.03 to 31 plf at 17.30
TC: From 62 plf at 17.30 to 62 plf at 20.80
BC: From 7 plf at 0.00 to 7 plf at 19.33
TC: 46 lb Conc. Load at 2.03,17.30
TC: 26 lb Conc. Load at 4.06, 6.06, 8.06, 9.67
11.27,13.27,15.27
BC: 59 lb Conc. Load at 2.03,17.30
BC: 25 lb Conc. Load at 4.06, 6.06, 8.06, 9.67
11.27,13.27,15.27
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 115 0.15 19.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to exceed
8.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or
notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1736 /- /- /- /445 /-
J 1736 /- /- /- /445 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.0
J Brg Width = 8.0 Min Req = 2.0
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 82 -25
B - C 657 -2747
C - D 534 -2385
D - E 440 -1898
E - F 506 -1835
Chords Tens. Comp.
F - G 506 -1835
G - H 440 -1898
H - I 534 -2384
I - J 657 -2747
J - K 82 -25
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - L 2350 -554
Chords Tens. Comp.
L - J 2350 -554
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - M 131 -275
D - N 213 -543
M - O 131 -274
N - O 211 -537
O - P 295 -781
P - L 428 -1112
P - Q 202 -148
F - Q 1158 -332
Webs Tens. Comp.
L - R 428 -1112
Q - L 1161 -334
Q - R 202 -148
R - S 295 -781
S - T 211 -537
S - U 131 -275
T - H 212 -542
U - I 131 -276
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
M - N 3 -13
E - P 110 -294
Gables Tens. Comp.
R - G 110 -294
T - U 3 -14
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.084 E 999 360
VERT(CL): 0.165 E 999 240
HORZ(LL): 0.031 L - -
HORZ(TL): 0.060 L - -
Creep Factor: 2.0
Max TC CSI: 0.580
Max BC CSI: 0.984
Max Web CSI: 0.618
Wgt: 124.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C01
Truss Type
GABL
Qty
1
Ply
1 2997
03/19/2021
19'4"
SEAT PLATE REQ.SEAT PLATE REQ.
9'8"9'8"
1'5"9 1'5"9
4"35'2"35'9"15A
B
C
D
E
F
G
H
I
J
KL
M
N
OP Q R S
T
U
6
12
3X6(A1)
3X6
4X4
4X6
6X6
3X6
3X6(A1)
2'0"6
59#
46#
2'0"6
25#
26#
2'
25#
26#
2'
25#
26#
1'7"4
25#
26#
1'7"4
25#
26#
2'
25#
26#
2'
25#
26#
2'0"6
59#
46#
2'0"6
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 115 0.15 19.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 825 /- /- /473 /360 /170
F 825 /- /- /384 /360 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
F Brg Width = 8.0 Min Req = 1.5
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 573 -1319
C - D 696 -1307
Chords Tens. Comp.
D - E 697 -1305
E - F 575 -1318
F - G 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 1131 -407
I - H 708 -193
Chords Tens. Comp.
H - F 1130 -413
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - I 265 -254
I - D 551 -262
Webs Tens. Comp.
D - H 545 -264
H - E 265 -254
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.043 I 999 360
VERT(CL): 0.081 I 999 240
HORZ(LL): 0.016 C - -
HORZ(TL): 0.029 C - -
Creep Factor: 2.0
Max TC CSI: 0.332
Max BC CSI: 0.983
Max Web CSI: 0.259
Wgt: 93.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C02
Truss Type
COMN
Qty
3
Ply
1 2979
03/19/2021
19'4"
SEAT PLATE REQ.SEAT PLATE REQ.
9'8"9'8"
1'5"9 1'5"9
4"35'2"35'9"15A
B
C
D
E
F
G
HI
6
12
3X4(A1)
1.5X3
3X4
4X4
5X6
1.5X3
3X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 115 0.15 19.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 825 /- /- /473 /360 /170
F 825 /- /- /384 /360 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
F Brg Width = 8.0 Min Req = 1.5
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 573 -1319
C - D 696 -1307
Chords Tens. Comp.
D - E 697 -1305
E - F 575 -1318
F - G 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 1131 -407
I - H 708 -193
Chords Tens. Comp.
H - F 1130 -413
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - I 265 -254
I - D 551 -262
Webs Tens. Comp.
D - H 545 -264
H - E 265 -254
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.043 I 999 360
VERT(CL): 0.081 I 999 240
HORZ(LL): 0.016 C - -
HORZ(TL): 0.029 C - -
Creep Factor: 2.0
Max TC CSI: 0.332
Max BC CSI: 0.983
Max Web CSI: 0.259
Wgt: 93.8 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C02
Truss Type
COMN
Qty
3
Ply
1 2979
03/19/2021
19'4"
SEAT PLATE REQ.SEAT PLATE REQ.
9'8"9'8"
1'5"9 1'5"9
4"35'2"35'9"15A
B
C
D
E
F
G
HI
6
12
3X4(A1)
1.5X3
3X4
4X4
5X6
1.5X3
3X4(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
(**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special
positioning requirements.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 18.71
BC 75 18.86 25.96
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Gable end supports 8" max rake overhang. Top chord must not be cut or notched.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Right bottom chord exposed to wind.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 815 /- /- /486 /166 /294
R 529 /-81 /- /472 /529 /-
Q 718 /- /- /717 /283 /-
N 228 /- /- /218 /90 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
R Brg Width = 8.0 Min Req = 1.5
Q Brg Width = 3.5 Min Req = 1.5
N Brg Width = 3.5 Min Req = 1.5
Bearings B, R, Q, & N are a rigid surface.
Bearings B & R require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 363 -1293
C - D 457 -1283
D - E 469 -1189
E - F 173 -394
F - G 172 -348
Chords Tens. Comp.
G - H 201 -317
H - I 152 -95
I - J 191 -79
J - K 288 -138
K - L 153 -31
L - M 85 -67
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - U 1109 -551
U - T 684 -387
T - S 684 -387
S - R 382 -198
Chords Tens. Comp.
Q - P 9 -8
P - O 50 -48
O - N 50 -48
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - U 217 -260
U - E 546 -194
E - V 77 -134
E - S 257 -401
V - W 71 -124
W - X 85 -146
X - Z 73 -129
H - Y 267 -583
Z -AB 82 -137
Webs Tens. Comp.
AA-AB 306 -649
AB- R 371 -761
R - Q 466 -549
Q - J 282 -335
K - P 314 -424
P -AC 63 -78
AC-AD 45 -53
AD- M 53 -62
M - N 163 -146
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
F - V 29 -21
G - W 40 -53
S - X 471 -104
Gables Tens. Comp.
Y - I 67 -93
Z -AA 22 -19
AC- L 148 -145
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.057 L 999 360
VERT(CL): 0.108 L 737 240
HORZ(LL): -0.047 L - -
HORZ(TL): 0.089 L - -
Creep Factor: 2.0
Max TC CSI: 0.430
Max BC CSI: 0.997
Max Web CSI: 0.818
Wgt: 200.2 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C03
Truss Type
GABL
Qty
1
Ply
1 3346
03/19/2021
19'2"4 6'9"4
SEAT PLATE REQ.SEAT PLATE REQ.
19'6'11"8
19'6'11"81'5"9
25'11"8
4"3 4'11"1'5"79'10"310'5"15(a)
A
B
C
D
E
F
G
H
I
JK
L
M
NOPQ
RSTU
V
W
X
Y
Z
AA
AB
AC
AD
6
12
3X4(A1)
3X4 3X6
3X6
3X8
3X4
4X6
3X4
3X6(R)
3X3
4X4 1.5X3(**)
3X4
3X3
1.5X4
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
(**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special
positioning requirements.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 18.71
BC 75 18.86 25.96
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Gable end supports 8" max rake overhang. Top chord must not be cut or notched.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Right bottom chord exposed to wind.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 815 /- /- /486 /166 /294
R 529 /-81 /- /472 /529 /-
Q 718 /- /- /717 /283 /-
N 228 /- /- /218 /90 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
R Brg Width = 8.0 Min Req = 1.5
Q Brg Width = 3.5 Min Req = 1.5
N Brg Width = 3.5 Min Req = 1.5
Bearings B, R, Q, & N are a rigid surface.
Bearings B & R require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 363 -1293
C - D 457 -1283
D - E 469 -1189
E - F 173 -394
F - G 172 -348
Chords Tens. Comp.
G - H 201 -317
H - I 152 -95
I - J 191 -79
J - K 288 -138
K - L 153 -31
L - M 85 -67
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - U 1109 -551
U - T 684 -387
T - S 684 -387
S - R 382 -198
Chords Tens. Comp.
Q - P 9 -8
P - O 50 -48
O - N 50 -48
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - U 217 -260
U - E 546 -194
E - V 77 -134
E - S 257 -401
V - W 71 -124
W - X 85 -146
X - Z 73 -129
H - Y 267 -583
Z -AB 82 -137
Webs Tens. Comp.
AA-AB 306 -649
AB- R 371 -761
R - Q 466 -549
Q - J 282 -335
K - P 314 -424
P -AC 63 -78
AC-AD 45 -53
AD- M 53 -62
M - N 163 -146
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
F - V 29 -21
G - W 40 -53
S - X 471 -104
Gables Tens. Comp.
Y - I 67 -93
Z -AA 22 -19
AC- L 148 -145
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.057 L 999 360
VERT(CL): 0.108 L 737 240
HORZ(LL): -0.047 L - -
HORZ(TL): 0.089 L - -
Creep Factor: 2.0
Max TC CSI: 0.430
Max BC CSI: 0.997
Max Web CSI: 0.818
Wgt: 200.2 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C03
Truss Type
GABL
Qty
1
Ply
1 3346
03/19/2021
19'2"4 6'9"4
SEAT PLATE REQ.SEAT PLATE REQ.
19'6'11"8
19'6'11"81'5"9
25'11"8
4"3 4'11"1'5"79'10"310'5"15(a)
A
B
C
D
E
F
G
H
I
JK
L
M
NOPQ
RSTU
V
W
X
Y
Z
AA
AB
AC
AD
6
12
3X4(A1)
3X4 3X6
3X6
3X8
3X4
4X6
3X4
3X6(R)
3X3
4X4 1.5X3(**)
3X4
3X3
1.5X4
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
X - H 480 -131 AD- O 126 -81
Truss
C03
Truss Type
GABL
Qty
1
Ply
1 3346
03/19/2021
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 117 0.15 18.71
BC 75 19.19 25.96
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high
x 24"-wide clearance.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Right bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 810 /- /- /486 /161 /294
J 803 /- /- /491 /660 /-
I 491 /- /- /760 /429 /-
H 258 /- /- /238 /98 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.5
I Brg Width = 3.5 Min Req = 1.5
H Brg Width = 3.5 Min Req = 1.5
Bearings B, J, I, & H are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 353 -1281
C - D 456 -1268
Chords Tens. Comp.
D - E 203 -431
E - F 171 -91
F - G 125 -104
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - M 1097 -541
M - L 682 -383
L - K 682 -383
Chords Tens. Comp.
K - J 302 -151
I - H 236 -258
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - M 212 -255
M - D 540 -187
D - K 312 -502
K - E 513 -138
E - J 339 -704
Webs Tens. Comp.
J - I 520 -509
I - F 92 -300
I - G 69 -80
G - H 176 -218
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.038 M 999 360
VERT(CL): 0.071 M 999 240
HORZ(LL): -0.014 F - -
HORZ(TL): 0.028 I - -
Creep Factor: 2.0
Max TC CSI: 0.865
Max BC CSI: 0.975
Max Web CSI: 0.492
Wgt: 155.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C04
Truss Type
SPEC
Qty
2
Ply
1 3349
03/19/2021
19'2"4 6'9"4
SEAT PLATE REQ.SEAT PLATE REQ.
19'6'11"8
19'6'11"81'5"9
25'11"8
4"3 4'11"1'5"79'10"310'5"15(a)
A
B
C
D
E
F
G
HI
JKLM
6
12
3X4(A1)
1.5X3
3X4 3X6
5X12
3X4
3X4
3X6(R)
4X6(R)
4X4
4X4
1.5X4
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 117 0.15 18.71
BC 75 19.19 25.96
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high
x 24"-wide clearance.
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Right bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 810 /- /- /486 /161 /294
J 803 /- /- /491 /660 /-
I 491 /- /- /760 /429 /-
H 258 /- /- /238 /98 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.5
I Brg Width = 3.5 Min Req = 1.5
H Brg Width = 3.5 Min Req = 1.5
Bearings B, J, I, & H are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 353 -1281
C - D 456 -1268
Chords Tens. Comp.
D - E 203 -431
E - F 171 -91
F - G 125 -104
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - M 1097 -541
M - L 682 -383
L - K 682 -383
Chords Tens. Comp.
K - J 302 -151
I - H 236 -258
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - M 212 -255
M - D 540 -187
D - K 312 -502
K - E 513 -138
E - J 339 -704
Webs Tens. Comp.
J - I 520 -509
I - F 92 -300
I - G 69 -80
G - H 176 -218
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.038 M 999 360
VERT(CL): 0.071 M 999 240
HORZ(LL): -0.014 F - -
HORZ(TL): 0.028 I - -
Creep Factor: 2.0
Max TC CSI: 0.865
Max BC CSI: 0.975
Max Web CSI: 0.492
Wgt: 155.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
C04
Truss Type
SPEC
Qty
2
Ply
1 3349
03/19/2021
19'2"4 6'9"4
SEAT PLATE REQ.SEAT PLATE REQ.
19'6'11"8
19'6'11"81'5"9
25'11"8
4"3 4'11"1'5"79'10"310'5"15(a)
A
B
C
D
E
F
G
HI
JKLM
6
12
3X4(A1)
1.5X3
3X4 3X6
5X12
3X4
3X4
3X6(R)
4X6(R)
4X4
4X4
1.5X4
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3 W2 2x6 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 9.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left and right cantilevers are exposed to wind
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
K 466 /- /- /405 /190 /103
I 467 /- /- /168 /130 /-
Wind reactions based on MWFRS
K Brg Width = 3.5 Min Req = 1.5
I Brg Width = 3.5 Min Req = 1.5
Bearings K & I are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 55 -79
C - D 169 -118
Chords Tens. Comp.
D - E 138 -118
E - F 50 -83
F - G 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
L - K 112 -16
K - J 138 -20
Chords Tens. Comp.
J - I 138 -20
I - H 127 -12
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - L 141 -90
C - K 287 -258
D - J 131 -99
Webs Tens. Comp.
I - E 299 -258
F - H 106 -90
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: > 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.034 D 999 360
VERT(CL): 0.063 D 999 240
HORZ(LL): 0.025 E - -
HORZ(TL): 0.051 E - -
Creep Factor: 2.0
Max TC CSI: 0.391
Max BC CSI: 0.319
Max Web CSI: 0.134
Wgt: 49.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
E01
Truss Type
COMN
Qty
1
Ply
1 2976
03/19/2021
1'2"8 6'11"1'2"8
4'8"4'8"
9'4"1'5"9 1'5"9
10"33'2"33'3"15A
B
C
D
E
F
G
HIJKL
6
12
1.5X3
1.5X3
1.5X3
1.5X3
4X4
1.5X3 1.5X3
1.5X3
1.5X3
1.5X3
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3 W2 2x6 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 9.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left and right cantilevers are exposed to wind
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
K 466 /- /- /405 /190 /103
I 467 /- /- /168 /130 /-
Wind reactions based on MWFRS
K Brg Width = 3.5 Min Req = 1.5
I Brg Width = 3.5 Min Req = 1.5
Bearings K & I are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
B - C 55 -79
C - D 169 -118
Chords Tens. Comp.
D - E 138 -118
E - F 50 -83
F - G 39 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
L - K 112 -16
K - J 138 -20
Chords Tens. Comp.
J - I 138 -20
I - H 127 -12
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - L 141 -90
C - K 287 -258
D - J 131 -99
Webs Tens. Comp.
I - E 299 -258
F - H 106 -90
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: > 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.034 D 999 360
VERT(CL): 0.063 D 999 240
HORZ(LL): 0.025 E - -
HORZ(TL): 0.051 E - -
Creep Factor: 2.0
Max TC CSI: 0.391
Max BC CSI: 0.319
Max Web CSI: 0.134
Wgt: 49.0 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
E01
Truss Type
COMN
Qty
1
Ply
1 2976
03/19/2021
1'2"8 6'11"1'2"8
4'8"4'8"
9'4"1'5"9 1'5"9
10"33'2"33'3"15A
B
C
D
E
F
G
HIJKL
6
12
1.5X3
1.5X3
1.5X3
1.5X3
4X4
1.5X3 1.5X3
1.5X3
1.5X3
1.5X3
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.98 to 61 plf at -0.10
TC: From 2 plf at -0.10 to 2 plf at 2.77
BC: From 2 plf at 0.00 to 2 plf at 2.77
TC: -25 lb Conc. Load at 1.46
BC: 10 lb Conc. Load at 1.46
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 31 0.15 2.77
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 139 /- /- /- /115 /-
D 34 /-5 /- /- /18 /-
C 20 /-17 /- /- /34 /-
Wind reactions based on MWFRS
B Brg Width = 10.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 19 -13
Chords Tens. Comp.
B - C 21 -11
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.103
Max BC CSI: 0.050
Max Web CSI: 0.000
Wgt: 12.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
HJ2
Truss Type
HIP_
Qty
2
Ply
1 2996
03/19/2021
SEAT PLATE REQ.
2'9"31'11"13
4"3 1'3"141'11"7A
B
C
D
4.24
12
2X4(A1)
1'5"8
10#
-25#
1'3"11
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.98 to 61 plf at -0.10
TC: From 2 plf at -0.10 to 2 plf at 2.77
BC: From 2 plf at 0.00 to 2 plf at 2.77
TC: -25 lb Conc. Load at 1.46
BC: 10 lb Conc. Load at 1.46
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 31 0.15 2.77
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 139 /- /- /- /115 /-
D 34 /-5 /- /- /18 /-
C 20 /-17 /- /- /34 /-
Wind reactions based on MWFRS
B Brg Width = 10.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 19 -13
Chords Tens. Comp.
B - C 21 -11
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.103
Max BC CSI: 0.050
Max Web CSI: 0.000
Wgt: 12.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
HJ2
Truss Type
HIP_
Qty
2
Ply
1 2996
03/19/2021
SEAT PLATE REQ.
2'9"31'11"13
4"3 1'3"141'11"7A
B
C
D
4.24
12
2X4(A1)
1'5"8
10#
-25#
1'3"11
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 218 /- /- /196 /709 /250
D 5 /-14 /- /75 /17 /-
C - /-40 /- /167 /50 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
Chords Tens. Comp.
B - C 75 -33
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.002 D - -
HORZ(TL): 0.002 D - -
Creep Factor: 2.0
Max TC CSI: 0.408
Max BC CSI: 0.053
Max Web CSI: 0.000
Wgt: 5.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
J1
Truss Type
JACK
Qty
4
Ply
1 2975
03/19/2021
SEAT PLATE REQ.
1'1'5"9
4"3 10"31'5"15A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 218 /- /- /196 /709 /250
D 5 /-14 /- /75 /17 /-
C - /-40 /- /167 /50 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
Chords Tens. Comp.
B - C 75 -33
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.002 D - -
HORZ(TL): 0.002 D - -
Creep Factor: 2.0
Max TC CSI: 0.408
Max BC CSI: 0.053
Max Web CSI: 0.000
Wgt: 5.6 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
J1
Truss Type
JACK
Qty
4
Ply
1 2975
03/19/2021
SEAT PLATE REQ.
1'1'5"9
4"3 10"31'5"15A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 22 0.15 2.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 209 /- /- /170 /93 /83
D 25 /- /- /17 /5 /-
C 26 /- /- /20 /26 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
Chords Tens. Comp.
B - C 12 -40
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.283
Max BC CSI: 0.058
Max Web CSI: 0.000
Wgt: 8.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
J2
Truss Type
EJAC
Qty
9
Ply
1 2974
03/19/2021
SEAT PLATE REQ.
2'1'5"9
4"3 1'4"31'11"15A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Value Set: NDS 2015
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 22 0.15 2.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent live load.
Wind
Wind loads based on MWFRS with additional C&C member design.
Wind loading based on both gable and hip roof types.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 209 /- /- /170 /93 /83
D 25 /- /- /17 /5 /-
C 26 /- /- /20 /26 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 39 0
Chords Tens. Comp.
B - C 12 -40
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.283
Max BC CSI: 0.058
Max Web CSI: 0.000
Wgt: 8.4 lbs
VIEW Ver: 20.02.01A.1209.11
Job
CRMSCMB3
Truss
J2
Truss Type
EJAC
Qty
9
Ply
1 2974
03/19/2021
SEAT PLATE REQ.
2'1'5"9
4"3 1'4"31'11"15A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
JANUARY 17, 2017 TYPICAL HIP / KING JACK CONNECTION
CORNERSET GENERAL SPECIFICATIONS
Attach King Jack w/ (3) 16d Toe
Nails @ TC & 24" Strap w/ (6)
10d x 1.5" ea. end @ BC
Attach End Jack's
w/ (4) 16d Toe Nails @ TC
& (3) 16d Toe Nails @ BC
Attach Corner Jack's
w/ (2) 16d Toe Nails
@ TC & BC (Typ)
Attach Corner Jack's
w/ (2) 16d Toe Nails @ TC &
BC (Typ) 7'-0" MAX ST-CRNRST
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
STDTL01
BC
JUNE 20, 2019
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL03ALTERNATE GABLE END BRACING DETAILFEBRUARY 17, 2017
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
OPTION #2: APA RATED GUSSET.
OPTION #3: 2X4 VERT. SCAB.
PIGGY-BACK TRUSS. (REFER
TO ACTUAL TRUSS DESIGN
DRAWINGS FOR ADDITIONAL
INFORMATION.)
** IMPORTANT NOTE **
THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES
SPACED AT 24" O.C. OR LESS.
PIGGY-BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY-BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
**REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY-BACK AND BASE
TRUSS SPECIFICATIONS.**
OPTION NO. 2 - APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS.
OPTION NO. 3 - 2X4 VERTICAL WOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) 10d BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
OPTION NO. 1 - TEE-LOK
3" x 8" TEE-LOK MULTI-USE CONNECTION PLATES SPACED
AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO
PIGGY-BACK TRUSS AT 4'-0" O.C. STAGGERED FROM
EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH
6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE
MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8"
TEE-LOK MULTI-USE CONNECTION PLATE (MINIMUM OF 2
PLATES).
OPTION #1: TEE-LOK MULTI-USE
CONNECTION PLATE.
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
BASE TRUSS. (REFER TO TRUSS
DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
2'-0"
MAX
PIGGY-BACK TRUSS STDTL04.112/23/19
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL05TRUSSED VALLEY SET DETAIL - SHEATHED
P 12
VALLEY TRUSS
(TYPICAL)
BASE TRUSSES
SEE DETAIL "A"
BELOW (TYP.)
VALLEY TRUSS
(TYPICAL)
GABLE END, COMMON
TRUSS, OR GIRDER TRUSS
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
DETAIL A
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR
EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
JULY 17, 2017
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO
SIMPSON SDS25412 (1/4" X 4.5")
OR EQUIVALENT WOOD SCREWS
INTO EACH BASE TRUSS.
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL06TRUSSED VALLEY SET DETAIL
P 12
VALLEY TRUSS
(TYPICAL)
BASE TRUSSES
SEE DETAIL "A"
BELOW (TYP.)
VALLEY TRUSS
(TYPICAL)
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
DETAIL A
(NO SHEATHING) N.T.S.
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
"A".
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
FEBRUARY 5, 2018
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO
SIMPSON SDS25300 (1/4" X 3")
OR EQUIVALENT WOOD
SCREWS INTO EACH BASE
TRUSS.
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL07TRUSSED VALLEY SET DETAIL
(HIGH WIND VELOCITY)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
SUPPORTING TRUSSES DIRECTLY UNDER VALLEY TRUSSES MUST BE
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
CLIP MUST BE APPLIED TO
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH)
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6/12 PITCH
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
NOTE: VALLEY STUD SPACING NOT TO
EXCEED 48" O.C. SPACING.
ATTACH VALLEY TRUSSES TO LOWER TRUSSES
WITH USP RT7 OR EQUIVALENT.
NON-BEVELED
BOTTOM CHORD
NON-BEVELED
BOTTOM CHORD
JULY 17, 2017
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
MAXIMUM STUD LENGTH
2X4 SP #3 / STUD 12" O.C.
16" O.C.
24" O.C.
2X4 SP #3 / STUD
2X4 SP #3 / STUD
2X4 SP #2 12" O.C.
16" O.C.
24" O.C.
2X4 SP #2
2X4 SP #2
3-8-10
3-3-10
2-8-6
5-6-11
4-9-12
3-11-3
6-6-11
6-6-11
5-4-12
11-1-13
9-10-15
8-1-2
3-10-15 5-6-11 6-6-11 11-8-14
10-8-0
9-3-13
6-6-11
6-2-9
4-9-12
3-11-3
3-6-11
3-1-4
3X4 =
12
A
A
* *
*
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH
DURATION OF LOAD INCREASE : 1.60
STDTL08STANDARD GABLE END DETAIL
B B
+
+
+
+
**
STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
CONNECTION OF BRACING IS BASED ON MWFRS.
FEBRUARY 17, 2017
**
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL09FEBRUARY 17, 2017
T-BRACE / I-BRACE DETAIL
WITH 2X BRACE ONLY
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL10FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
45.00°45.00°45.00°
STDTL11FEBRUARY 17, 2017 LATERAL TOE-NAIL DETAIL
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
L
STDTL12FEBRUARY 17, 2017 UPLIFT TOE-NAIL DETAIL
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 5, 2016 ST-2x2 NAILINGTYP 2x2 NAILER ATTACHMENT
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
1.5 x 4
1.5 x 4
2 x 4 SP No . 2 (M in )2x4 SP No. 2 (Min)
2x2 SP No. 3
STDTL13
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
April 11, 2016 ST-FLAT GIR BRACETYPICAL ALTERNATE BRACING DETAIL
FO EXTERIOR FLAT GIRDER TRUSS
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
(4) 12d
MAX 30" (2'-6")
2x6 #2 SP (Both Faces)
24" o.c.
SIMPSON H5
(4) 12d
TRUSS 24" o.c.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
VARIES
12
STDTL14
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL15FEBRUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND
DAMAGED OR MISSING CHORD SPLICE PLATES
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STDTL16FEBRUARY 17, 2017 SCAB APPLIED OVERHANGS
(L)
24" MAX
(2.0 x L)
24" MIN
Rama Pranav Kristam, P.E.# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946