HomeMy WebLinkAbout103449 Avalon by the Beach Lot #20_PLANS·······Notes & DetailsMichael CrawfordMATTER MINUTESSE SERVICE DESIGN DEPARTMENTFP-126R3V-BTRM Construction Management, Inc.1512 SE Village Green DriveWindermere, Florida 34786St. Lucie County5/20/2021103449Avalon By The Beach151 Ocean Estates Drive (Lot 20)Fort Pierce, Florida 34949SCOPE OF WORK:1. W.A.F.S. TO INSTALL A NEW 13D FIRE SPRINKLER SYSTEM THROUGHOUT NEW RESIDENCE.2. W.A.F.S. TO CONNECT 1'-0" AFF AND INSTALL A NEW FIRE SPRINKLER RISER CONSISTING OF A LEAD FREE 1" WILKINS 950XLT2 DUAL CHECK BACKFLOW PREVENTOR.NOTES:1. ALL UNDERGROUND FIRE SPRINKLER PIPING WILL BE (BY OTHERS) AND NOT IN W.A.F.S. SCOPE OF WORK.3. ALL FIRE SPRINKLER PIPING AND FITTINGS TO BE CPVC.2. PER NFPA 13D, A FLOW SWITCH IS NOT REQUIRED TO BE INSTALLED ON THE SPRINKLER SYSTEM .3. PER FBC 901.6.1 EXCEPTION #1, MONITORING OF THE FIRE SPRINKLER SYSTEM IS NOT REQUIRED.4. PER NFPA 13D, A CONTROL VALVE IS OPTIONAL ON THE FIRE SPRINKLER SIDE OF THE RISER. A CONTROL VALVE IS NOT INCLUDED ON THE FIRE SPRINKLER RISER. Notes & DetailsMichael CrawfordMATTER MINUTESSE SERVICE DESIGN DEPARTMENTFP-226R3V-BTRM Construction Management, Inc.1512 SE Village Green DriveWindermere, Florida 34786St. Lucie County5/20/2021103449Avalon By The Beach151 Ocean Estates Drive (Lot 20)Fort Pierce, Florida 34949 BEDROOM 3WICLOFTFROM ABOVEBATH 3BATH 2BEDROOM 2CL.LINENSPRINKLEREDSTUDYGARAGEENTRYFOYERBATH 4CL.DINNINGCL.WICMASTER BATHLAUNDRYOUTDOOR LIVINGMASTERKITCHEN2" REDUCED PRESSURE DETECTOR 2" 10-0 AWWA VALVEEXISTING CIRCULATING WATER MAIN(INSTALLED BY OTHERS)DOMESTIC WATER LINE(INSTALLED BY OTHERS)FIRE SPRINKLER POINT OF SERVICE6"1 1/2" CPVC 30-0 1 1/2" CPVC 3-0(BY OTHERS)W.A.F.S. POINT OF CONNECTION1'-0" AFFEXISTING CIRCULATING WATER MAIN6"(BY OTHERS)(BY OTHERS)(BY OTHERS)(NIC)(NIC)(NIC)(NIC)(NIC)SPRINKLER RISER DESIGNED TO NFPA 13D 2016 EDITION FIGURE A.6.2(c)FIRE HYDRANT FLOW TEST RESULTSSTATIC: 63 PSIRESIDUAL: 30 PSIFLOW: 900 GPMPER NFPA 13D 2016 EDITION 8.3.4SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES1" x 13'-0" UP TO 2ND FLNO A/S6 SQ.FT. PANTRYNO A/S43 SQ.FT. NO A/S43 SQ.FT. 1 8 x 1 8 2 0 x 2 0 2 0 x 2 0NO A/S13 SQ.FT. NO A/S14 SQ.FT. CL.NO A/S19 SQ.FT. 2 0 x 2 0 1 8 x 1 8 1" x 13'-0" DN TO 1ST FLNO A/S6 SQ.FT. 20x20 1" METER(NIC)(BY OTHERS)2" 5-0 18x18 NO A/S35 SQ.FT. NO A/SDESIGN AREA #1COMPARTMENT DESIGN PER NFPA 13D, SECTION 10.2.1R00944NDOMESTIC DEMAND - GPM13.0S116' X 16'SPACINGGPM @PSI7.013.0S216' X 16'SPACINGGPM @PSI7.0N/ADESIGN AREA #2COMPARTMENT DESIGN PER NFPA 13D,SECTION 10.2.1R00942NS3SPACING20' X 20'SINGLE SPRINKLER PROOF CALCULATION120.016.7DOMESTIC DEMAND - GPMN/AGPM @PSIDESIGN AREA #3COMPARTMENT DESIGN PER NFPA 13D,SECTION 10.2.1R00942NS3SPACING20' X 20'SINGLE SPRINKLER PROOF CALCULATION120.016.7DOMESTIC DEMAND - GPMN/AGPM @PSI1 1/2" CPVC50-0(BY OTHERS)(NIC)Fire Sprinkler PlanMichael CrawfordMATTER MINUTESSE SERVICE DESIGN DEPARTMENTFP-326R3V-BTRM Construction Management, Inc.1512 SE Village Green DriveWindermere, Florida 34786St. Lucie CountyNN5/20/2021103449Avalon By The Beach151 Ocean Estates Drive (Lot 20)Fort Pierce, Florida 34949