Loading...
HomeMy WebLinkAboutAPPROVED Plans2INSPECTOR NOTE: STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA BUILDING CODE AND ASCE 7-10, 170 MPH (3 SEC), EXP. C. _RISK CAT. 2. EXISTING FASCIA TO REMAIN NO CHANGES \ \\ • c INSPECTOR NOTE REPAIRS ARE OF A LEVEL 1 ALTERATION IN ACCORDANCE WITH 503.1 OF THE EXISTING BUILDING CODE. i EXISTING WOOD TRUSSES @ 24" 0/C, NO CHANGES EXISTING CONCRETE BEAM, NO CHAN a NEW SYP No. 2 PT 2x8 FASTENED TO EXISTING RAFTER W/ (3) #120 SDS SCREWS AND TO EXISTING CONCRETE BEAM W/ SIMPSON HGAM10 AND (4) J"Ox1j" SDS SCREWS TO TRUSS AND (4) J"x2j" TITEN 2 ANCHORS TO CONC BEAM CLIENT INFORMATION FLORIDA HOME IMPROVEMENTS 3044 SW 42nd STREET FORT LAUDERDALE, FL 33312 Z /1 \N REPAIR DETAILS 2/9/2021 SYP No.2 2x6 HEAD PLATE FASTENED TO EACH 2x8 \ a W/ SIMPSON A34 AND (4+4) 10dxl�" HDG NAILS SYP, No.2 2x6 HEAD PLATE FASTENED TO ,jT CONC BEAM @ END W/ W/ SIMPSON HGAM10 244" VIF AND (4) j"0x1j" SDS SCREWS TO TRUSS AND ANGLED NTS PROVIDE 15# FELT PAPER (4) J"x$' TITEN 2 ANCHORS TO CONC BEAM TO SEPARATE PLYWOOD AND CONCRETE, TYPICAL (2) LAYERS OF J" CDX PLYWOOD TO FIT FOOTPRINT OF EXISTING BAY WINDOW. FASTEN TO CONC BEAM W/ (2) ROWS OF "'Ox2j" TAPCONS 0 8" O/C AND TO 2x6 I BLOCKING W/ #14xq" SDS SCREWS @ 6" O/C, STAGGERED NEW WINDOWS AND MULLIONS BY OTHERS. SEE 1/S1 3—COAT STUCCO FINISH OVER TYVEX (2) SYP No. 2 2x4 SILL PLATE AND PAPER BACKED WIRE LATH. SIMPSON LSTA18 BAY CORNERS MATCH EXISTING FINISHES AND CONDITIONS. SECURE LATH W/ HDG NAILS," HEAD, W/ (14) 10dx2" HDG NAILS DRIVEN TO FULL PENETRATION AND NOT LESS SIMPSON SPH4 @ SILL PLATE W/ THAN 2 NAILS / SQUARE FOOT. (6 10dxli" HDG NAILS 19/32" PLYWOOD WALL SHEATHING NAILED SYP No. 2 2x4 STUDS @ ENDS AND 16 W/ 8d RING SHANK NAILS 6" 0/C TO ALL O/C FASTENED TO SILL PLATE W/ SIMPSON MEMBERS AND 4" 0/C IN CORNERS. SPH4 AND TO BTM PLATE W/ SIMPSON A34 J" GYPSUM WALLBOARD. MATCH EXISTING CONDITIONS SIMPSON A34 W/ (4+4) 10dxl�" HDG NAILS R-19 BATT INSULATION EXISTING CONCRETE FOUNDATION SYP No. 2 2x4 PT BTM PLATE AND SLAB. NO CHANGES FASTENED TO CONC SLAB W/ TAPCONS ®8" 0/C, STAGGERED 0 2 REPAIR SECTION 03 SCALE: i —1/2" = 1'-0" PROJECT INFORMATION RAIVELY RESIDENCE (1159416) 5902 KILLARNEY AVENUE, FORT PIERCE, FL 34951 BAY WINDOW REPAIR SPECIALTY ENGINEERING CONSULTANTS, Inc 61 NEF,p�y 1599 SIN 30th AVE. SUITE BOYNTONOBEACH, FL 33426 ti DAM — BROWARD — PALM BEACH Out FL. CA. 1009217 561 — 752 — 5440 OFFICE 561 — 752 — 5542 FAX NOTES 1. TAPCONS SHALL BE ULTRACON BY ELCO ( 1 X" MIN. EMBEDMENT, 2 hi" MIN. EDGE DIST.) 2. ALUMINUM SHALL BE 6063—T6 MIN. 3. ALL FASTENERS SHALL BE GALVANIZED MIN. 4. WATERPROOFING, BY OTHERS. 5, OPENING SIZE AND STRUCTURE LOADING DOES NOT CHANGE 6. PROVIDE BARRIER BETWEEN ALUMINUM AND CONCRETE. 7. PROVIDE BARRIER BETWEEN ALUMINUM AND WOOD S. ALL WOOD TO BE SOUTHERN YELLO PINE, No. 2, AND PRESSURE TREATED U.N.O. 9. NOTlFY THIS ENGINEER OF ANY DISCREPANCIES. 244" VIF 494 VIF ANGLED NTS I I�' Q0 = 1 N. 1 PARTIAL ELEVATION S3 SCALE: 1 /2" = 1'-0" 1 rrrrrlrry�,'/ rd