HomeMy WebLinkAboutPlans391'-0"267'-0"82'-6"169'-0" 34'-9"138'-0"74'-4"NSEW5'-1"8'-10"23'-11"10'-6"SHEET INDEX:A-00: COVER SHEETA-01:SITE PLANS-01:ATTACHMENT DETAILE-01:ELECTRICAL LINE DIAGRAME-02:ELECTRICAL NOTESE-03:WARNING LABELSDS-01+DATA SHEET ROOF ACCESS POINTROOF ACCESS POINT(S) SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORSAND ARE LOCATED AT STRONG LOCATIONS OF BUILDINGCONSTRUCTION THAT DO NOT CONFLICT WITHOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.SCALE: NTS2SATELLITE VIEWA-00SCALE: NTS3VICINITY MAPA-00SCALE: 3/128" = 1'0"1PLOT PLANA-00SYSTEM SIZE: 9.860 kW DC8.410 kW ACMODULE TYPE & AMOUNT: (29) Q.PEAK DUO BLK-G6+/AC 340MODULE DIMENSIONS:(L/W/H) 68.5"/40.6"/1.57"INVERTER:(29) ENPHASE IQ7PLUS-72-2-US [240V]INTERCONNECTION METHOD: SUPPLY TAPPHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM29 MODULES-ROOF MOUNTED - 9.860 kW DC, 8.410 kW AC, 2395 S ROCK ROAD, FORT PIERCE, FL 34945ROOF ACCESS POINTGOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODESa. 2017 NATIONAL ELECTRICAL CODEb. 2020 FL BUILDING CODE - 7TH EDITIONc. 2020 FL BUILDING CODE - 7TH EDITION RESIDENTIALd. FLORIDA FIRE PREVENTION CODEe. ANY OTHER LOCAL AMENDMENTSREVSTEWART.J RESIDENCE 2395 S ROCK ROAD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERA-00SHEET NAMEPROJECT NAMESIGNATURE WITH SEALCOVERSHEETTHIS DIGITAL PDF PLAN SET WAS ELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE DATE SHOWN USING IDENTRUST. THISCOVER PAGE SEALS ALL SUBSEQUENT PAGES OF THIS PLAN SET.PRINTED COPIES ARE NOT CONSIDERED SIGNED AND SEALED AND ALLSHA-1 AUTHENTICATION CODE MUST BE VERIFIED.GENERAL NOTES:1.APPLICABLE CODE: 2020 FLORIDABUILDING CODE (7TH EDITION) & ASCE 7-16MINIMUM DESIGN LOADS FOR BUILDINGAND OTHER STRUCTURES.2.LAG SCREW DIAMETER AND EMBEDMENTLENGTHS ARE DESIGNED PER 2020FLORIDA BUILDING CODE (7TH EDITION)REQUIREMENTS. ALL BOLT CAPACITIESARE BASED ON A SOUTHER YELLOW PINE(SYP) RESIDENTIAL WOOD ROOF RAFTERSAS EMBEDMENT MATERIAL.3.ALL WIND DESIGN CRITERIA ANDPARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROMA 7° TO A MAXIMUM 23° (5/12 TO AMAXIMUM 7/12 PITCH) ROOF IN SCHEDULE.CONTRACTOR TO FIELD VERIFY THATMEAN ROOF HEIGHT DOES NOT EXCEED30'-0".4.ROOF SEALANTS SHALL CONFORM TOASTM C920 AND ASTM 6511, AND IS THERESPONSIBILITY OF THE CONTRACTOR TOPILOT DRILL AND FILL ALL HOLES.5.ALL DISSIMILAR MATERIALS SHALL BESEPARATED WITH NEOPRENE WASHERS,PADS, ETC OR SIMILAR.6.ALL ALUMINIUM COMPONENTS SHALL BEANODIZED ALUMINIUM 6105-T5 UNLESSOTHERWISE NOTED.7.ALL LAG SCREW SHALL BE ASTM A276STAINLESS STEEL UNLESS OTHERWISENOTED.8.ALL SOLAR RAILING AND MODULES SHALLBE INSTALLED PER MANUFACTURERINSTRUCTIONS.9.CONTRACTOR SHALL ENSURE ALL ROOFPENETRATIONS TO BE INSTALLED ANDSEALED PER 2020 FLORIDA BUILDINGCODE (7TH EDITION) OR LOCALGOVERNING CODE.PROPERTY LINEPROPERTY LINE DRIVEWAYFRONT OF HOUSE 2395 S ROCK ROADMAIN HOUSEPROPERTY LINEMROOF #1(13) Q.PEAK DUO BLK-G6+/AC 340SLOPE: 23°AZIM.: 178°ROOF #2(04) Q.PEAK DUO BLK-G6+/AC 340SLOPE: 23°AZIM.: 268°ROOF #3(12) Q.PEAK DUO BLK-G6+/AC 340SLOPE: 23°AZIM.: 88°SHED STRUCTURESTRUCTUREEXISTING EXTERIOR MAINSERVICE PANEL TIED TOEXTERIOR UTILITY METERSHE D PROPERTY LINE FENCE 14'-3"13'-9"6"11'-6"3'-0"5'-8"6'-4"7'-4"12'-9"4'-0"16'-10"3'-0"3'-6"11'-6"3'-0"4'-11"24'-2"8'-11"3'-0"3'-10"66'-7"60'-0"NSEW8'-10"23'-11"10'-6"SCALE: 3/32" = 1'-0"1SITE PLANA-01MODULE, ARRAY WEIGHT(LOAD CALC'S)Number of Modules29Module Weight47.2LBSTotal Module (Array) Weight1368.80LBSNumber of Attachment point73Mounting System Weight(Per Module)1.5LBSMounting System Weight109.50LBSTotal System Weight(Module Weight + Mounting System Weight)1478.30LBSWeight at Each Attachment Point(Array Weight / Number of Attachment Point)18.75LBSModule Area (68.5"x40.6")19.31SqFtTotal Array Area560.08SqFtDistributed Load(Total System Weight / Total Array Area)2.52Per SqFtTotal Roof Area3034SqFtTotal Percentage or Roof CoveredTotal Array Area / Total Roof Area)*10018.46%SYSTEM LEGENDNEW DEDICATED PV SYSTEM BREAKER PANEL.M29 NEW Q.PEAK DUO BLK-G6+/AC 340 MODULES WITHNEW 29 - ENPHASE IQ7PLUS-72-2-US [240V]MICROINVERTERS, MOUNTED ON THE BACK OF EACHMODULES.= CONDUIT EXTERIOR RUN= ATTACHMENT POINTS= RAFTER= ROOF OBSTRUCTIONS= WIND ZONE 1= RACKING SYSTEM= WIND ZONE 2e, 2n AND 2r= WIND ZONE 3r AND 3eNEW SOLADECK JUNCTION BOX.JBREVSTEWART.J RESIDENCE 2395 S ROCK ROAD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERA-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEALSITE PLANGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SEE RAFTERS SHALL BEINSTALLED AS SHOWN IN SHEET S-01 AND ASFOLLOWS FOR EACH WIND ZONE:WIND ZONE 1, 2e: 4'-0" O.C.WIND ZONE 2n, 2r AND 3e : 4'-0" O.C.2) PERIMETER WIDTH IS 4 FT IN ALL CASES AS PER THE2020 FBC 7TH EDFRONT OF HOUSE 2395 S ROCK ROAD CONTRACTOR IS PERMITTED TO SHIFTAND/OR RELOCATE MODULES TO CLEARROOF TOP OBSTRUCTIONS AND FORIMPROVED PERFORMANCE. FIELDVERIFICATION OF ACTUAL DIMENSIONS ISREQUIRED,EXISTING EXTERIOR MAIN SERVICE PANEL & POINT OFINTERCONNECTION. TIED TO EXTERIOR UTILITY METER.DESIGN CRITERIAROOF LIVE LOAD (psf)20GROUND SNOW LOAD (psf)0WIND SPEED (mph)157EXPOSURE CATEGORYBROOF HEIGHT (ft.)30ROOF LENGTH (ft.)66ROOF WIDTH (ft.)60PARAPET HEIGHT (ft.)0DESIGN CALCULATIONWIDTH OF PRESSURE COEFFICIENTROOF LENGTH x 10% (ft.)6.6ROOF HEIGHT x 40% (ft.)12.0ZONE WIDTH "A"4.0'WIND ZONE 1 AND 2e-45.900WIND ZONE 2r, 2n AND 3e-66.100WIND ZONE 3r-75.900CTHIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED.MODULE RATING IS -75.0 PSF SO IT MAY BE INSTALLEDIN ALL ROOF ZONES.= CONDUIT ATTIC RUNMACROOF SECTIONSMODULE-12SLOPE-23°AZIMUTH-88°MATERIAL-COMP SHINGLERAFTER SIZE-2"X4" @ 24" O.C.MODULE- 04SLOPE-23°AZIMUTH-268°MATERIAL-COMP SHINGLERAFTER SIZE-2"X4" @ 24" O.C.MODULE- 13SLOPE- 23°AZIMUTH- 178°MATERIAL- COMP SHINGLERAFTER SIZE-2"X4" @ 24" O.C.ROOF#01ROOF#02ROOF#03CIRCUIT(S)CIRCUIT #3 - 4 MODULESCIRCUIT #2 - 12 MODULESCIRCUIT #1 - 13 MODULESNEW PHOTOVOLTAIC UTILITY DISCONNECTSWITCH. LOCATED WITHIN 10' OF MSP.AC= FIRE PATHWAY36" FIRE SETBACK36" FIRE PATHWAY36" FIRE PATHWAYROOF #02 ZONE 2n IS A 4 FTWIDE ZONE FROMTHE SIDEZONE 2r IS A 4 FT.ZONE FROM RIDGEDOWNC36" FIRE SETBACK36" FIRE SETBACK ROOF #03 18" FIRE PATHWAY18" FIRE PATHWAYJB ZONE 3r IS A 4 FTSQUARE CORNERSAT RIDGE36" FIRE PATHWAY4 FT SQUARE CORNERSARE ZONE 3eZONE 1PRESSURES WERE INTERPOLATED FROM THECOMPONENTS AND CLADDING TABLE ON PAGE 25 FORGABLE ROOFS IN THE 2020 FBC 7TH ED RESIDENTIAL FORRISK II EXPOSURE B ENCLOSED STRUCTURES.AN ADJUSTMENT FACTOR OF 1.21 WAS USED TOCONVERT FROM EXPOSURE B AT 30 FT TO EXPOSURE CAT 13 FT. SITE IS EXPOSURE CWIND SPEED USED WAS 157MPH FROM ATC, ROOF PITCHWAS 23 DEGREES AND THE AFFECTED AREA IS 18 SQ FT.ROOF #01ZONE 2e IS A 4 FTWIDE ZONE ALONGTHE EAVE18" FIRE PATHWAY18" FIRE PATHWAY REVSTEWART.J RESIDENCE 2395 S ROCK ROAD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERS-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEALMOUNTDETAILPV MODULE(E) COMP SHINGLE ROOF2"X4" RAFTER @ 24" OCPV MODULESIRONRIDGE XR-100 RAILQUICKMOUNT FLASHING5/16" EPDM BONDED304-18.8 SS WASHERQUICKMOUNT L-FEETIRONRIDGE INTEGRATED GROUNDING& END/MID CLAMP2"X4" RAFTER @ 24" OCSEE (2/S-01) FORENLARGED VIEWSCALE: NTS1ATTACHMENT DETAIL (SIDE VIEW)S-015/16"x3" SS LAG BOLT WITH MIN 2-1/2"THREAD EMBEDMENT, SEALEDPENETRATIONSCALE: NTS2ATTACHMENT DETAIL ENLARGED VIEWS-01THIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED. REVSTEWART.J RESIDENCE 2395 S ROCK ROAD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL3-LINEDIAGRAMRooftop conductor ampacities designed in compliancewith art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a),310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9.Location specific temperature obtained from ASHRAE2017 data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP0°C33°CCONDUIT HEIGHT0.5"ROOF TOP TEMP55°CCONDUCTOR TEMPERATURE RATE OFF ROOF75°CCONDUCTOR TEMPERATURE RATE ON ROOF90°CENPHASE Q CABLE TO BE ATTACHED TO RAILMIN. 3-1/2" ABOVE ROOF SURFACESYSTEM DATATOTAL MODULES:29TOTAL INVERTERS:29SYSTEM RATINGS:9.860kW DC STCTHIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED.WIREQTYWIRETAG #CONDUITWIRE TYPEINVERTERQTY:NOC:CONDUITFILL:TEMPRATING:WIREAMPTEMPDE-RATE:WIREOCP:GRNDSIZEGRND WIRETYPEWIREGAUGE:TERMINAL75°C RATING:NEC:STRINGAMPSxx=xx=1.251.2113#6SBC19.66A38.40A35A90°35Axx=1.251.2113#8THWN-219.66Axx=24.32A90°50Axx=1.251.2129#8THWN-243.86Axx=47.00A75°40A#1040A#1050A#8WIRE FROM - -JUNCTION BOX TO COMBINER PANELCOMBINER PANEL TO ACDARRAY TO JUNCTION BOX123THWN-2THWN-26N/A0.8031.000.960.760.94TRUNKCABLETHWN-2665Axx=1.251.212943.86Axx=61.10A75°65A#6ACD TO MAIN SERVICE PANEL4THWN-231.000.943/4" EMTGN200AM(E) LOADS(E) LOADSGN4EXISTING GROUNDINGELECTRODE SYSTEM3GL1L1L2L213 MICRO-INVERTERS IN BRANCH CIRCUIT #1L2L2L1L112 MICRO-INVERTERS IN BRANCH CIRCUIT #2L2L2L1L14 MICRO-INVERTERS IN BRANCH CIRCUIT #3TERMINATOR CAP ON LAST CABLECONNECTOR AC TRUNK CABLE (TYP)L1L2NGNG10AM*Envoy-S20A12POINT OF INTERCONNECT, SUPPLY SIDE TAPEXISTING 240V/200A BUS BAR RATING,MAIN SERVICE PANEL, SINGLE PHASE,WITH A 200A MAIN DISCONNECT(N) LOCKABLE BLADE TYPEFUSIBLE AC DISCONNECT60A-2P 120/240VAC40A FUSESSOLADECK BOX OR UL 1741APPROVED EQUIVALENT TOTRANSITION FROM Q-CABLETO THWN-2 WIRE NO FUSEREQUIREDCOMBINER PANEL ENPHASE IQCOMBINER X-IQ- AM1-240-3 64A/240VCONTINUOUS, PROTECTION MAX 80ABREAKER ON SOLAR OUPUT; WITH 10KAIC CIRCUIT BREAKERSLINE SIDE TAP20A20A3/4" EMT3/4" EMT 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND90 DEGREE C WET ENVIRONMENT.3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSEAS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OFSYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARYOUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TOFULFILL APPLICABLE CODES AND STANDARDS.6.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, ANDCONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALLSIZE THEM ACCORDINGLY.7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELYLABELED AND READILY VISIBLE.8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEENMODULE FRAME AND MODULE SUPPORT RAIL, PER THEGROUNDING CLIP MANUFACTURER'S INSTRUCTION.9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUSCOPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-INLUG.10.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THESERVICE ENTRANCE.11.WORKING CLEARANCES AROUND THE EXISTING AND NEWELECTRICAL EQUIPMENT WILL BE MAINTAINED INACCORDANCE WITH NEC ARTICLE 110.26.12.ALL EQUIPMENT INSTALLED SHALL BE LISTED BY ANATIONALLY RECOGNIZED TESTING LABORATORY (NRTL)PER NEC ARTICLE 110.3.13.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.14.ALL LABELS OR MARKINGS SHALL BE VISIBLE AFTERINSTALLATION. THE LABELS SHALL BE REFLECTIVE, AND ALLLETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUMHEIGHT OF 9.5 MM (3/8 IN) IN WHITE ON A RED BACKGROUND.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) ANDARTICLE 310.8 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BESUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE310.8 (C).REVSTEWART.J RESIDENCE 2395 S ROCK ROAD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-02SHEET NAMEPROJECT NAMESIGNATURE WITH SEALSYSTEM NOTES:1.ENPHASE IQ7 / 7PLUS MICROINVERTERS DO NOT REQUIREGROUNDING ELECTRODE CONDUCTORS OR EQUIPMENTGROUNDING CONDUCTORS. THE MICROINVERTERS ITSELF HASCLASS II DOUBLE-INSULATED RATING, WHICH INCLUDES GROUNDFAULT PROTECTION.2.ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLEINSULATED CABLING)3.MODULES ARE BONDED TO RAIL USING UNIRAC INTEGRATEDGROUNDING.4.RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS5.SYSTEM IS UNGROUNDED6.BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIAIRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC250.64(C)7.SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTALBRANCH CIRCUIT.8.ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRALTO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PERENPHASE INSTALLATION INSTRUCTIONS.9.ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READYPER NEC 690.12PV MODULE RATING @ STCMANUFACTURERMAX. POWER-POINT CURRENT (IMP)MAX. POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)10.02 AMPS33.94 VOLTS40.66 VOLTS10.52 AMPSNOM. MAX. POWER AT STC (PMAX)MAX. SYSTEM VOLTAGEVOC TEMPERATURE COEFFICIENT340 WATT1000 VDC-0.27° %/°CQ.PEAK DUO BLK-G6+/AC 340ELECTRICAL NOTES:ELECTRICALNOTESCERTIFICATE OFAUTHORIZATION#31930ENGINEER OF RECORDJOHN L. ALGERPROFESSIONAL ENGINEERFL. LICENSE NO. 74730 I JOHN L ALGER, PE#74730, AN ENGINEERPURSUANT TO CHAPTER471 OF THE FLORIDASTATUTES, HERE BY STATETHAT I HAVE EVALUATEDALL OF THE COMPONENTSAND THE SYSTEM AS AWHOLE AND CERTIFY THATIT MEETS OR EXCEEDSTHE REQUIREMENTS OF:PHOTOVOLTIAC AC OUTPUTAC OUTPUT CURRENTNOMINAL AC VOLTAGE240V35.09ALABLESRATED MPP CURRENTRATED MPP VOLTAGE38.00 V9.60 APHOTOVOLTAIC DC PER INVERTERMAX SYSTEM VOLTAGESHORT CIRCUIT CURRENT44.30 V10.26 VSYSTEM DATA# STRINGS:03SMALLEST STRING:04LARGEST STRING:13TOTAL MODULES:29TOTAL INVERTERS:29SYSTEM RATINGS:9.860kW DC STCBATTERY RATING:N/AINVERTER SPECIFICATIONSMANUFACTURERMAX. POWER AT 40 C60 VOLTSNOMINAL AC VOLTAGE235 WATTSMAX. AC CURRENT290 VOLTSMAX. OCPD RATINGMAX. PANELS/CIRCUITSHORT CIRCUIT CURRENT1.21 AMPS20 AMPSMAX. DC VOLT RATING1315 AMPSENPHASE ENERGY IQ7PLUS-72-2-USTHIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED. INVERTER OUTPUT CONNECTIONPHOTOVOLTAIC SYSTEMCOMBINER PANELNOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIREDBY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USINGEFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT ORWIRING METHOD AND SHALL NOT BE HAND WRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCTSAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.WARNING!SOURCES: UTILITY GRIDAND PV SOLAR ELECTRICSYSTEMDUAL POWER SUPPLYLABEL LOCATION:UTILITY SERVICE METER AND MAIN SERVICEPANEL.PER CODE(S): NEC 2017: 705.12(D)(3), NEC 2011: 705.12(D)(4)ELECTRICAL SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONWARNING!LABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): CEC 2019: 690.17(B),NEC 2017: 690.17(E), NEC 2011: 690.17(4)WARNING!DO NOT RELOCATE THISOVERCURRENT DEVICELABEL LOCATION:ADJACENT TO PV BREAKER (IF APPLICABLE).PER CODE(S): CEC 2019: 705.12(B),NEC 2017: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7)!DO NOT ADD LOADSWARNINGLABEL LOCATION:PHOTOVOLTAIC AC COMBINER (IF APPLICABLE).PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC2017: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4)WARNING: PHOTOVOLTAICPOWER SOURCEWARNING: PHOTOVOLTAICPOWER SOURCELABEL LOCATION:INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACHTURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULLBOX CONTAINING DC CIRCUITS.PER CODE(S): CEC 2019: 690.13, NEC 2017: 690.31(G)(3),690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012:605.11.1.4LABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.54, NEC 2011: 690.54MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 35.09 AMPS 240 VACPHOTOVOLTAIC AC DISCONNECTASOLAR PV SYSTEMEQUIPPED WITH RAPIDSHUTDOWNTURN RAPIDSHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUTDOWN PVSYSTEM ANDREDUCESHOCK HAZARDIN THE ARRAYSOLARELECTRICPV PANELSREVSTEWART.J RESIDENCE 2395 S ROCK ROAD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-03SHEET NAMEPROJECT NAMESIGNATURE WITH SEALWARNINGLABELSTHIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED.