Loading...
HomeMy WebLinkAboutBuilding PlansSafe Load Table Notes Installation Notes 1. All values based on minimum 4" nominal bearing. 1. Installation of U lintels must comply with architectural Exception: Safe loads for unfilled U lintels must and/or structural drawings. be reduced by 20% if bearing length is less than 6 1/2". 2. U lintels can be field cut to the required length. 2. N.R. = Not Rated 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 3. Safe loads are superimposed allowable loads. 4. The exterior surface of U lintels installed in exterior 4. One #7 rebar may be substituted for two #5 concrete masonry walls shall have a coating of stucco - rebar in 8 inch U lintels only. applied in accordance with ASTM G-926 or other approved coating. 5. All safe loads in units of pounds per linier foot. 5. Concrete masonry units used in composite U lintel shall 6. All safe loads are based on simply supported span. be laid in a running bond. 7. Safe load ratings based on rational design analysis 6. Shore composite lintels as required. per ACI 318 and AC1 530, 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical cell reinforcing and x5 reb...t ta°. grout. N nt,qu bm of of rebar. et bottom of IieR°I cavity.abiala°' r F=fllelcou[ Composite U Lintel Materials 1,U) � 8 F 16-1 B 1 T 1 • Grout per ASTM C476 fg7-3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 0. fared ca°team j 2. Rebar per ASTM A615 Grade 60 lintel . " qu.nity of #5 beret bottom nominal robe, a tap any n°" 3. Concrete masonry units (GMU) per ASTM 090 with minimum net area compressive strength = 1900 psi Lintel Type Designation 4. Mortar per ASTM C270 Type M or S Cast in place sill or Tie Beam k Option In the event that precast products are damaged in the field cast in place sills and tie beams may be used (not to exceed 5'-10`") Typical cast in place tie beam to be a min. 8`` x 12f" with (2) #5 top and (2) #5 bottom Flat Cone. Tile Roofing over "Peel and Stick Pre Engineered Wood underlayment on 5/8" Roof Trusses 24o.c. c.d.x. plywood fastened as Shop Drawings by ' per nailing schedule Others See Connector Provide Metal Channels at Schedule Hip and Ridge locations to Support Cap Tiles - Galv. Drip Edge 2 over 1 x 3 p.t. Spray Foam Insulation per ` �"�x Fascia Energy Code 10'-0" gK T.O.B. Building Data Design Loads Scope of Work Occup ncyjType: Group Roof Live Load: 20.0 p.s.f. New One level CBS Construction Type: V Floor Live Load: 40.0 p.s.f.; Single Family residence Number of Stories: One Wind Speed: 160 MPH Projec Area: 930 s.f. Wind Importance Factor: 1.0 Building Category: U Building Code Wind Exposure: B Area Tabulation Internal Pressure Coefficent: .18 2020 Florida Building Code: Residential Structure Designed: Enclosed 2017 National Electrical Code: NFPA 70 Soil bearing capacity: 2000 p.s.f. Living: 750 Entry 180 Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Total: 930 Flame Spread Index & Smoke Developed Index Total Cubic Insulation Flame Spread: Not to exceed 25 Volume: 7,749 c.f. Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 O Cast Ci in N ate Lintel Schedule All Rebar to be #5 Grade 60 min, MARK NGTI'if OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 4'-6- 8672 159 4292 85 8F24-1B/1T L-2 T-0" 8974 167 5591 100 8F24-1B/1T L-3 5'-10" 6036 167 3295 100 8F24-1 B/1 T L-4 6'-4" 2177 502 1340 315 1 8F12-1B/1T L-5 4'-4" 8060 1597 4409 1126 8RF22-1B/1T L-6 6'-0 3480 167 1880 100, 8F16-1B/1T L-7 14'-4" 1370 297 519 375 8F16-1B/1T Stucco Soffit over High Ribbed Wire 1/2" d.w._ Lath Fastened to 1 x 4 Trusses, Provide (1) Firestop Layer of #15 Felt on Two Course Perimeter Trusses under Lath Beam with (1) #5 Rebar T-0" Provide Venting at Filled with Grout each Entry Area course 8x16x8 CMU Typ. 1 x 2 p.t; furring trips 2411o.C. over 3/4" Insul. Board 1/2" d.w\ Stud Finish over #5 vert. rebar in Condrete Block. grout filled cell See Floor Plan for Locations 4 3000# Fibermix-Cone. #5 Vert. Rebar with on .006 Visquine on Clean 10" Hook and 30" Compacted, Termite Lap. Tie to Vert. Treated Fill Rebar In Cells a J O M F.F.E. v v Grade F-1 N • 18" x 16" 3000# Cont 1'-6"" Conc. Mono. Footing with (2) #5 rebars cont Typical Wall Section Min. Beam depths shown, beams may be increased without comment At Lintels 'over 24" deep, provide (1) #3 vertical rebar at 24"o.c. along length of lintel Left Elevation scale: 1 /4" _ 1'd1" T-9," 12'-3" L-4 60" x 20" FIX. Glass 0 El v.t.r. _IE]l Kill 0 I lall o water line Ref. O R ange& -- Exh. Hood T-2" 6'-8" T-2" T 6" 3 -11 T-7" Kitchen 1 T 10'-0"" Cling. Cing." iD T ioFWWafla _ p r dw W _F7--- II CVI l l _ Co r L _ J 2 x 4 Frame 34.5- Tall 2880 1 22.5 x 36 2880 ❑' 14 Pocket 1 Attic s.h. — — — — — I Access Living Rm. I i ❑ L-2 Cing. & 12- Coffer ❑ 110-0" k Master Bdrm. I N I 35 10'-0- Ceiling s.h. r I ., p *- t • r L-3 d' o Electric r Fireplace HB 16'-9" 7„ 11'-0" cc 14 in ;.h. o L-2 "' L-5 or L-1 25 s.h. Egress -Low co Entry 010 L-6 10'-0" Cing; from F.F.E. I ❑ QO fl❑ QO CIS 0❑ L-7 13,_0„ Floor Plan scale: 1 /4" = V-0" Front scale: 1/4" _ Rear Elevation scale: 1/4" = 1'-0" M L-7 8'-2 13'-0" ai �i- Qr ttf N \/ Lu lt1 o0 0 fU�z Lij 4'-10" a 16- drawn sJ. checked a.t date, 2/23/21 scale as noted job number 21012 sheet A-1 REVIEWED FO14 li CODE COMPLIANCE ST. LUCIE COUN� BOCC FH Lil mount y rlooc \ Light Electrical Plan Scale: 1 /4" = 1'-0" ELECTRICAL LEDGEND jO RECESSED LIGHT WITH LENS 0 EXTERIOR & WET LOCATIONS -E:}- SURFACE MOUNTED LIGHT FIXTURE 1--- Te -IT SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE. WITH EXHAUST FAN CEILING FAN 0 EXHAUST FAN OUTLET DOOR CHIMES bTHERMOSTAT SMOKE & CARBON MONOXIDE DETECTOR $ DUPLEX OUTLET,- SWITCHED �+ TELEVISION =0 DUPLEX OUTLET'. .0 220 V OUTLET TELEPHONE Y/J SWITCH PUSH BUTTON -to. THREE WAY SWITCH � DIMMER SWITCH D NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46- A.F.F. ALL 120V SINGLE PHASE''. 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS ALL LIGHTING TO BE L.E.D. Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. Ensure min. 36" clear between equipment and disconnects, Typical. 5. Protective ratings shall comply with NEC 110-9 & NEC 110-10 6. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1 Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI Electrical contractor to verify all equipment loads prior to start of construction.!, Electrical contractor to recalculate electrical schedule if loads are to be modified SOITIL mount Rear od Lts. FORMWORK & SHORING Electrical Load Calcs No structural concrete shall be stripped until it has reached at least 80% of the 28 day design strength. 750 Livingl S.F. at 3 VA 2,250 watts Design, Erection, & Removal of all formwork, shores, & reshores shall meet Two 20 Amp Appliance Ckts. 3000 watts meet the ACI Standards 347 and 301 One LaunarV Circuit 1500 watts Range 8000 watts Contractor to verify all building setbacks prior to the start of construction. A formboard survey shall be submitted to the building department for One Dishwasher & Disposal 3000 watts approval prior to pouring concrete. One Microwave 2000 watts Water Heater 4500 watts SOIL STATEMENT: One Ref. I 1500 watts OneBath! 1500 watts Foundation has been designed for a soil bearing capacity of 2000 p.s.i. Fill shall be laid in layers of 6". Each layer to be compacted to 95% Total 27,250 watts compaction. First 10 KVA at 100% 10,000 watts If the contractor encounters, while digging the foundation, any Rem finder at 40% $,900 watts discrepancy to suggest the soil may be inadecuate, he must immediately report it to the owner and the Architect or Engineer Total16,900 watts so as to order a soil boring test. One AC Meat at 100% 5,700 watts Total 22,600 watts GENERAL FOUNDATION NOTES 22,600 W / 240 V = 94.17 Amps Concrete shall be a minimum of 4- thick over clean, compacted, termite treated fill and 6 mil polyethylene vapor barrier. Use 1 OOA Service (Minimum) If concrete slab contains 6" x 6" 10/10 WWM rovide 1- covera e o F-1 18" x 16' mono, footing ' wi�Yh (2) #5 rebar cont. 16" 18„ M NO. EDGE FOOTING F— Recess 4- at Shower 4"" 4„ 4 Reber TYP. SHOWER' RECESS F— 18" z 16- mono. footing with (2) #5 rebar cont. 4„ 18" STEP FOOTING P g 1 Concrete shall have at minimum compressive strength of not less to than 3,000 p.s.i. aI All 90% hooks are to be extended 10" minimum beyond the turn. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six bar diameters. Minimum coverage for rebar shall be 3" in footings and 1 1/2" in bond beams. Hooks may be rotated horizonitally if required to achieve minimum coverages. Rebar overlap shall be 48 bar diameters. 30" for #5 rebar The foundation design assumes that the soil has a minimum load carrying capacity of 2000 p.s.f. In the event the soil bearing capacity falls below 2000 p.s.f. This foundation plan may be superseded by Foundation Design Engineer. Satisfactory compaction test of fill does not verify lower soils are adequate. All specifications and dimensions to be verified by contractor. All exterior slabs shall slope a minimum 1 /8" per foot for drainage C Fo Dowel Rod -Repair Note In the event vertical steel has been omitted from the down11 pour locations, drill 5 into concrete (no closer than 3 3/4 from edges and 5" from ends of cap walls) Remove dust per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either "Hilti C-100" or Simpson Epoxy -Tie. 2" v.t.r. .1 to sanitary system V Plumbing contractor to provide a water hammer & shut off valve at each fixture Insulate all hot water lines Plumbing Riser Diagram PLUMBING NOTES: Plumber to consult with contractor and equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. All sanitary lines 2-for less shall have a slope of 1 /4- per foot minimum. All sanitary lines above 2' shall have a slope of 1/8" per foot minimum. Provide Anti -Scalding Valve in all showers. Lowest living area floor elevation (refered as 0.00') to be set by a professional land surveyor to the required building department elevation, but not less than 18" above the crown of the road. 5'-0" 5'-0" 4'-11" 4" 2500# Conc. Pad 11 El F-1 E� E W F-1 0 0 1 0 e io I co ❑ � � XF-3 �I o co T-2- 10'-8'" 3'-7" LID 1 CV M B LO N M 4" 3000# FIBERMIX CONC. F-1 d c OVER .006 VISQUINE ON CLEAN, N F-1 COMPACTED TERMITE TREATED p FILL 0.00' -l$l­ Assumed F.F.E. ih 0 I d' See Civil Drawings for the established F.E.E. R T I in LO F-2 F-2 � (h R I] 1 F Q m al -4" 010 F-1 6'-10 T-11 ,n F-1 00 4 .' I � I � - 0❑ F-1 ❑❑ F-1 ❑� ❑o oS o❑ Foundation & Footing Plan scale: 1/4 " = V-0" Roof Framing Plan U I CL 0 cli co co �L1 `J UJ Z "t M C C3 .. J LL cfl wJ uJ U I a co 0 J LI- Q .. v Z d U W J v, �\\ LU m W '4-) v J ICU ai v cu In LU •= C-4 LO r ...o r co00 � _CDZ CD _ U LLI C Q 00 r 0 L1. 4-J V) Z ILL r_' 0 0 Lu uJ N 4-) U mom-+ 2 LU I J 06 Z W LLJ L Q 0 LL �. li F- Z LU a W date revision ''..., 4/5/21 Load Calcs, drawn checked s.l. data ''.. 2/23/21 scale as noted job number. 21012 sheet A-2 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC I V STRUCTURAL NOTES:• st GENERAL ROOFING NOTES Ceramic Tile el shall be hi strength billet steel and shall All reinforcing ste gh gt Roofing to be composed of and attached to pre manufactured Shall be installed in accordance with ANSI A108.1, A108.4, A108.5 A108.6, A108.11, A118.1, A11$.3, A136.1, & A137.f. Fiber mat reinforced conform to ASTM A-615 grade! specifications. Lap continuous wood trusses as follows: reinforcing 48 bar diameters or':30" in beams and in slabs. Lap backer shall be used behind wall applied ceramic tiles in the tub bottom steel over supports and to steel at mids an. Hook pP p P Felt underlayment (min. ASTM 0 226 Type 8) with 4 min. side and fasten resistant annular nog shank nails and shower areas and conform to ASTM C1325. Per Ourock, discontinuous ends of all top bars. Reinforcing steel shall have at 6 o.. and in staggered at 6"0.0, in laps and in staggered rows spaced 12"o.c. in Feld. cement board exceeds ASTM C1325. a minimum of I" concrete cover, or as follows: If roof pitch is < 4/12 install (2) layers 15# felt If roof pitch is 4/12 or greater, install (1) layer 30# felt. BOTTOM TOP SIDES Gypsum Note Beams: 1 1/2" 1 1/2" 1 1/2" 5/8" c.d.x. sheathing or equal installed with staggered joints & GI clips, nailed to trusses with 8d corrosion resistant annular ring shank nails Gypsum board shall conform to ASTM 022, 0475, C514, C1002, C1047 Slab on Grade: 1 1/2" 1" - spaced max. 6 o.c. throughout, except max. 4 o.c. at gable ends. C1177, C1'178, 01278, 01396, or 01658 and installed per FBC residential Structural Poured: 3/4"' 3/4""" _ Poured Walls. 3/4 All roof trusses are to be re manufactured assemblies provided by P P code. Per USG, Wallboard conforms to C1396. _ _ Slabs exposed " a licensed wood truss fabricator with separate drawings and data prepared for actual project conditions by a'Florida registered to the weather 3/4"" 1 - professional engineer certified for truss design. Any deviation from Gypsum Board & Gypsum Panel Products the Pro osed plans as shown regarding PI cement'or bearing shall -- i accordance teal shall be detailed and fabricated. n acco a Reinforcing s with the Manual of Standard Practice of Reinforcing be brought to the attention of the truss engineer nor to fabrication g g p ed layout shall govern, of the trusses. The truss manufacturer's certified board and gypsum panel products shall be applied .Detailing Concrete Structures' and the current ACI Building Code 318"" after fabrication. at right angles or parallel to framing members. All edges and ends of gypsum board and gypsum panel products shall ATM Specification A-36 All structural steel shall conform to current S P The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mf r's. occur on framing members, except those edges and ends that r Interior are perpendicular to the framing members. nteno gypsum All wood in contact with masonry shall be pressure treated or approved drawings and data board shall not be installed where it is directly exposed to seperating material. All engineered headers and truss hangers to be provided by the weather or to water. truss manufacturer. All dimensions shall be verified in field by the contractor. if there are any discrepancies the Architect or Engineer shall be notified before Splitting or cracking of structural components due to installation of Wall and ceiling gypsum board shall be fastened with screws spaced at 12 o,c. Screws for attaching gypsum board and gypsum proceeding. hardware is not permitted. panel products to wood framing shall be Type W or Type S in Unless otherwise noted, the installation of specified hardware shall accordance with ASTM C1002 andshall penetrate thewood not No slump over 5" shall be permitted for any structural concrete without conform to the truss manufacturers installation instructions and less than 5/8 inch (15.9mm) Gypsum board and Gypsum anal P the Architect or Engineer approval ' . standardractice P products shall be attached to cold formed steel framing p $ less than 0,033"" (1 mm) thick shall be Type S in accordance with All Design and Construction shall be inaccordance with the current ASTM C1002 or bugle head style in accordance with ASTM C1513 American Concrete institute (ACI). and the American Institute of Steel SHEATHING NAILING NOTES and shall penetrate the steel not less than 3/8" to 0.112 " Construction (AISC), The Florida Building Code and all applicable (1mm to 3mm) thick shall be in accordance with ASTM C954 or local codes. bugle head style in accordance with ASTM 1513. Screws for Nailing Pattern Nailing Schedule attaching gypsum board or gypsum panel products to structural Structural Concrete shall attain a minimum ultimate compressive strength insulated anles shall penetrate the wood structural panee p facing g (Fe') in 28 days as follows: Zone 1: 8d at 6-o.c. field & 4"o.c. edges ROOF & FLOOR DIAGRAMP ' not less than 7/16"�o.c, 01.1 mm). Zone 2: 8d at 4"o.c. edges &field Use sheathing with #8 gun mill at 6'o.c. Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof: see column schedule. Zone 3: 8d at 4-o.c. edges & field at supported panel edges a nails at6 o.c. at intermediate d #8 Igun supports. Gypsum board used as the base orbacker for adhesive application All other concrete: 3000 p.s.i.; Pneumatic Nails of ceramic tile or other required nonabsorbent finish material shall conform to ASTM 01396, C1178, C1278. Use of water resistant Footing sizes and reinforcing are based. on allowable soil bearing ROOF SHEATHING TO GABLE Pneumatic or mechanicaly driven nails will be accepted under the following conditions: Use #8 gun nails at 4o.c. END FRAME sum backing board shall be permitted on ceilings. Water gyp, g -- P g resistant gypsum board shall not be installed over a Class 1 or capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before Class 2 vapor retarder in a shower or tub compartment. Cut or proceeding with the work. Min. nails size 8e er larger rin shank with 6 Min. shank diameter..113 '.EXTERIOR SHEATHING exposed edges, including those at wall intersections shall be P B � g Min. Length: 2" Use #8 gun nails at4'o.c. at panel edges sealed. as recommended by the manufactuer. Water resistant Timber (Heavy Timber Construction) Min. Head Dismeter:.280 Full Round and #8 gun nails at 4"o.c. at panel top and gypsum backing board shall not be used where there will be (a) Truss manufacturer shall submit a signed and sealed shop Min. Ring Diameter .012 over shank dia. bottom and 6 o.c. in field direct exposure to water, or areas subject to continuous high drawings by a registered Engineer. Min. 16 to 20 Rings per Inch humidity. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. Note (c) Roof members should be secured to the beams or other - Cold Formed Steel Note structural components with hurricane anchors for wind: uplift. tru P P Gun nails shall be permitted as an acceptable fastener from an manufacturer p y Cold formed steel framing supporting gypsum board and gypsum All wood members shall have a'minimum fiber stress in bending Wood screws meeting the same size requirement panel products shall be not less than 1 1/4' (32mm) wide in the of 1200 p.s.i. with 1 /360 max. deflection. may be used in lieu of nails without comment I d' N L d b Id f d t I f ea imension. on oa earing co orme s ee rammg All bolted connections shall be 1/2" Cadmium plated or better. shall comply with AiSi S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AISI S200 Lag bolts to be used only in shear connections with minimum Wire Lath Attachment and ASTM'C955, Section 8. 4"' threaded penetration past steel plate. paper _.., Over wood framingthe Lag bolted conditions shall be drill tapped no larger than the backed Wire lath shall be Installed Wood Framing Note \ internal thread diameter and shall not be hammer driven. over one layer of approved plastic house wrap. Lath shall be attached Wood framing supporting gjrpsum board avnd gypsum panel ses rovide horizontal fra in members with 1.5- products shall be not less than 2" (51 mm) nominatthirkness Ulys atfrframelocations equal rum m. g P Y roofin8 nails" 2nd to vertical wood in th least dimension except that wood furring strips not less framing members with $d common than i" by 2 (25mm x 51mm) nominal dimension shall be „ permitted be used over solid backing or flaming spaced GENERAL REQUIREMENTS P "" G Q nails or 1 roofing Halls driven to not more than 24 o.c. 610mm o a n edition of the Florida Building Code penetration of not less then 3/4 .All work to be as per the current e t g and meet or exceed all applicable local requirements. of an inch or 1 wire staples driven flush with the plaster base. General contractor is responsible for all labor, materials, utilities, testing, Staples shall have crowns not less waste removal, storage, securing of site, accomodation, transport/freight, than 3/4" and shall engage not less and all other cost related to the completion of this project., unless explicitly than three strands of lath and identified here. penetrate the wood framing members Owner is responsible for all municipal related charges such as impact not less than 3/4" The fasteners must fees, and water connection, except building permit fees, which are to be penetrate the wood framing members 5 s included in the construction bid. not less than 3/4". Fasteners shall be General contractor to check all drawings for errors and om7 o.c. max. a 4missions and , bring them to the attention of the architect prior to starting any work, or Ab- aA ordering any materials of the respective division of work. if such errors s s and ommissions`are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to Wind Zones _ Walls clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. comer bars at.beam (outside only) (2) corner 4' Unless otherwise noted, the installation of specked hardware shall bars at footing (min.) conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been b the Building Department reviewed and approved B e n 3 _ PP Y g P 3 n the building permit has been issued. wart, dowel lapped with 3 2 d and a gP e 3 wall reinforcing, all all corner bars to be the laps 3 el (mir.) in grout same size, number, and EXTERIOR CEILING & SOFFIT NOTE filled cell spacing as horizontial bars 7/8" Stucco finish over 3/8"" high ribbed gals. wire lath fastened to in footing, beams, and walls 2 1 framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" 2 dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c. 2 Install one layer of 15# felt to framing prior to installing ribbed lath INTERIOR WALL FRAMING NOTE 2 Interior non bearing walls to be 2 x 4 studs 24'o.0. Spruce, Pine, Fir (SPF) #2 Grade lumber or better 2 1 1 or metal studs (25 Ga.) Crimper may be used in 2 lieu of screws. THRESHOLD NOTE 2 2 At egress door (see floor plan) the max. hgth. o 0 of the threshold shall be 1/2" s • 2 2 BUCK ATTACHMENT NOTES 1 AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH 3 2 3 TO BLOCK WITH 1/4" DIA. TAPCONS INTO C.B.S. 3 3 SET AT 6" FROM CORNERS AND AT 12"o.c. MAX. 30'".lap min. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR "T"' NAILS" 4" FROM ENDS AND 12" o.c. Roof Win CD f p t •I W d Zones USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION VI'"Wil V 111 O1�ko"6 V 0I Alum, window frame corrosive resistant Tapcon concrete 3/8" continuous bead of screws installed as caulk (back bedding)behind specified in window shim to prevent liquid passage manufacturers product approval 1/4"" struct. shi window sill set flange in continuous bead of caulk across the entire face of buck perimeter caulk T stucco finish c c € Gunable sealants shalt comply with ° ASTM C 920 Class 25 grade or c. 4 . a greater roper'oint expansion B P J p and contraction precast cone. sill Typical Precast Conc. Sill Detail 2 x 4 bottom cord bracing Bottom Cord Lateral Bracing 3/8" continuous bead of caulk (back bedding) behind buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck �1i ' w o e'c g 1 N n¢ ;,goy 30M E 0 oo b0 C N O N m f 0 l 3okR 0 M Connector Schedule ' Truss Bearing Truss Connector Qnty' Connector Fasteners Point Uplift ID Uplift All trusses ALL <1000 MTS18 1 1000# (14) 10d x 1 1/2" to Frame All trusses ALL <800 HETA20 1 1810# (9) 10d x 1 1/2" to CBS Connector Schedule Developilld from the Truss Placement Plan and Engineering from East Coast Truss Company Job Number J40998 Dated 1/4/21 Attic Vents Calculation ENTRY" Attic Area: 180 s.f. / 150 = 1.2 s.f. required. soffit area = 50 Lf. x 1.8 = 90 s.f. Venting Provided: 8 x 16 soffit vent: 85 sq_ in, each vent 3 Vents along overhang = 255 sq. in. 255 sq. in. / 144 = 1.77 s.f. Total Ventilation Provided: 9.44 sq. ft. ° Q a d . d CBS Min.':1 1/4" embedment a at windows and min. X 1 1/2 embedment at al. gl. doors ° drywall stucco finish perimeter caulk J/ 1/4" maxi struct. shim Attach p.t. bucks with 8d coil nails at caulk 12"o.c. attach as per Typ. Alum. window manufacturers jamb or sliding glass product approvals doorjamb NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured concrete sill. greater for. proper joint expansion and contractioh Coat Bucks with LWM200 Waterproofing after they have been installed and Chaulked Window & Door Flashing Detail at CBS Wall Includes Buck Attachment Me thod Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers specs. Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to approve temporary bracing to prevent toppling of trusses, see HIB-9. Other specs, if different from above, have priority. A.T.R. = All Treaded Rod Drill and Epoxy Set all A.T.R. Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy Provide equal number of studs, under girders equal to the number of plys. Missed Tie Down Strap Note In the event the Tie Down Strap has been omits Layout location, install one MTS18 strap at the Fasten with (4) 1/4" x 2 1/4•" Hex Head Titan and (7) 10d x 1 1/2" to truss. MAXIMUM UPL' from the per location, w to C.B.S. 1000 lbs. Product Approval Affidavit Form Category Subcategory Approval Numbers Manufacturer Model Number Glass Type Attachment Method Building Design Pressures Product Rated Design Pressures A. EXTERIOR DOORS Swinging FL#: 253.4 PGT FD750 Impact Head &Sill: 6" from corners. Jambs: I I" from comers and 18 1/2 o.c. max. Use Total of (5) anchors. Use 1/4" dia' Tapcons with 1 1/4" embedment in concrete, +38.7 -42.1 +70.0 -80.0 B. WINDOWS Singlehung FL#: 239.7 PGT 5500 Impact Head & Sill: 6" from corners and 15"'o.c. Jambs: 6'" from comers and 14" o.c, Max. 4" from meeting rail Use 3/16"Tapcon with 1 1/4" embed. into concrete +38.7 -50.0 +50 / -50 Fixed FL#: 243.10 PGT 5540 Impact Head & Sill: 6" from corners and 8-o.c. Jambs: 6- from corners and 8" o.c. Use 3/16" Tapcon with 1 3/4" embeded into concrete +40.5 -54,0 +/- 70.0 D. ROOFING PRODUCTS Roof Tiles FL#: 7849.4 Boral Tile Flat (Bermuda) Adhesive Set -45.0 -102.3 Roof Underlayment FL#: 5259.1 Polyglass USA Polystick TU Plus Direct bond to deck 65.2 -135.0 V l:1 N rn Lu d V Z ch C7 J LED � bIA �' v W >` I A?Lill a 00^ Q J (y N U Z i V o ; o COCD to Q� W will �a5 C� >' U co'to �Qw.P_N tO 1 t L o � n =oz U o W tCf Q Co T_ O LL Z o ` '> a LL Lu � 0 in Ill*� _. C/a J 0 m •ate-+ . HLu JW Lu 06 ZQ W Uj J c ~ o LL S H Z W a date revision drawn e.i. checked date 2/23/21 scale as noted job number 21012 sheet A-3 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC'