Loading...
HomeMy WebLinkAboutMain DrainCERTIFICATION OF COMPLIANCE SQUARE GRATE:,,,, Contents: 1 Part Number: 640-472xV Description: Square Grate p N' Size: 12" x 12" Open Area: 62.4 in' GPM @ 1.5 fps: 292 UL Floor Flow Rate: 356 GPM Wall Flow Rate: 280 GPM VGB 2008 Date of Manufacture: 110 8 2 4 2 0 2 Q 0 Date of Installation: Name of Installer: Signature of Installer: This product has been tested, certified and listed to the requirements ofASME/ANSI A112.19.8-2007, ASME/ANSI A112.19.8a- 2008, ASME/ANSI A112.19.8b-2009 and APSP-16-2011 per §1404 ofthe Virginia Graham Baker (VGB 2008) Pool and Spa Safety Act. Certified by: Underwriters Laboratories, Inc., 2929 E. Imperial Highway, Suite 100, Brea, CA 92821-6729 This product is certified to comply with §1404 of the Virginia Graham Baker (VGB 2008) Pool and Spa Safety Act. A copy of the test results for the above may be found at www.waterwayplastics.com or go to: www.ul.com. This product is manufactured by Waterway Plastics, Oxnard CA 93030 Designed, , ,waterway._ Engineered & Manufactured 2200 Fast Sturgis Road Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403 in the USA, waterway@waterwayplastics.com • www.waterwayplastirs.com 02020eaur aynanw 1110-0253.0320 GRATE AND FRAME OWNER'S MANUAL For Model Number: 640-4720(12" x 12") IN WARNING Read and keep these instructions for future reference. Follow all instructions in this 2008 A owner's manual and on the equipment. Failure to follow instructions can cause severe injury and/or death. IMPORTANT SAFETY INSTRUCTIONS WARNING - SUCTION ENTRAPMENT HAZARD ,� Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or unsecured can cause severe injury and/ or death due to the following entrapment hazards; Hair Entrapment: Hair can become entangled in suction outlet cover. Limb Entrapment: A limb inserted into an opening of suction outlet sump or suction outlet cover that is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. Body Suction Entrapment: A negative pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration / Disembowelment Entrapment: A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in evisceration / disembowelment entrapment. Mechanical Entrapment: There is potential forjewelry, swimsuit, hair decorations, finger, toe, or knuckle to be caught in an opening of a suction outlet cover resulting in mechanical entrapment. TO REDUCE THE RISK OF ENTRAPMENT HAZARDS: n� • Use two or more suction fitting on each lul pump suction line. The suction fittings shall be separated by a minimum of 3 ft. O� (91.44 cm), or if any are located closer they shall be located on two different planes (i.e., one on the bottom and one on the vertical wall, or one each on two separate vertical wall). In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump(s) for the specific suction system. Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. The maximum system flow rate shall not exceed the flow rating of any listed (per ASME Al 12.19.8-2007) suction outlet cover installed. In the event of one suction outlet being completely blocked, the remaining suction outlets serving the system shall have a flow rating capable of the full flow of the pump(s). • Never use a pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. • Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. • Two or more suction outlets per pump should be installed in accordance with latest APSP Standards and CPSC guidelines, and follow all National, State, and Local codes applicable. • Replace the suction within 7 years from the installation date. • Installation of a vacuum release system, which relieves entrapping suction, is recommended. USE ONLY GENUINE SUPER PRO REPLACEMENT PARTS. Screws Grat1 Gra« Flame Head Loss Curve -12" x 12" 3S 3 23 s 2 e $ 13 1 as 0 0 SO Mo ISO 200 2% 300 350 000 4S0 500 Flow Rate (GPM) ®2018 Waterway Plastics Head Lou Curve - 9" x 9" 6 S 0 3 a 2 1 0 0 SO 100 ISO 200 250 300 Ho 400 Now Rate (GPM) 810-0213.0618 WARNING AFailure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets can result in an increased potential for suction entrapment as described on the previous page. AFailure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material, can result in an increased potential for suction entrapment as described on the previous page. ASuction outlet components have a finite life. The cover/grate should be inspected frequently and replaced at least every seven years, or if found to be damaged, broken cra cked, asked, missing, or not securely attached. AThe 12" x 12" fitting is rated at 356 GPM for floor and 280 GPM for wall. If the fitting is missing or broken, replace with a fitting of equivalent rating or higher. Use of a lower rated suction fitting could result in entrapment of the body which could result in serious injury including drowning. ADo not use or operate pool, spa, or hot tub if this suction fitting is missing, broken or not secured per instructions. The suction fitting is intended to prevent entrapment of the body. Use of the spa hot tub with a missing, broken or improperly secured suction grate may result in serious personal injury including drowning. AWhen the pool, spa or hot tub is in operation, suction is created at this fitting. Users of the spa or hot tub must be instructed not to come in contact with this fitting in such a way as to block its orifice. If a user of the spa or hot tub blocks this fitting with his/her body, serious personal injury or drowning may occur. ®In order to remove the suction cover (for service or winterization), using a Phillips -head screw driver remove the screws. Inspect both the suction cover and suction fitting for any cracks or damages. AIt is imperative to securely attach the suction cover to the wall fittings (use only the original supplied screws or obtain original replacements). Do not over tighten the screws. Inspection of fasteners and observation for damaged/tampered with suction fittings is required. ®Any and all broken or missing parts must be replaced prior to starting spa or pool pump. Never operate spa or pool without drain cover in place and properly affixed, death or serious injury can result. ADo not exceed the safe flow rate. Do not increase flow through system by increasing pump size or horsepower. ADo not allow children to sit, play or interact with main drains or suction outlet. 102018 Waterway Plastics 810-0213.0618 INSTRUCTIONS FOR THE USE OF FIELD BUILT SUMPS A D min. G GENERAL NOTES: (a) D = inside diameter of pipe. (b) All dimensions shown are minimums. (c) A broken line L _ J indicates suggested sump configuration. FIELD BUILT SUMP B J D min. The design of field fabricated sumps shall be further specified by a Registered Design Professional so as to fully address the considerations of cover/grate loadings, durability, hair, finger, and limb entrapment issues, as well as features particular to the site. LIMITED WARRANTY Waterway Plastics manufactures its products and equipment in accordance with very high standards of workmanship. We use the best materials available and maintain the highest quality procedures practical in the industry. For Warranty, product must be registered at time of purchase/installation at www.waterwayplastics.com. For Warranty claims or questions, please contact point of purchase, Super*nra CR) genuine replacement parts Designed, Engineered by % / / Manufacturedd / in the USA. waterway-M 02020 Waterway Plastics 810-0213-SG.0320