HomeMy WebLinkAboutMain DrainCERTIFICATION
OF COMPLIANCE
SQUARE GRATE:,,,,
Contents: 1
Part Number: 640-472xV
Description: Square Grate
p N'
Size: 12" x 12"
Open Area: 62.4 in'
GPM @ 1.5 fps: 292
UL
Floor Flow Rate: 356 GPM
Wall Flow Rate: 280 GPM
VGB
2008
Date of Manufacture:
110 8
2 4 2 0 2 Q 0
Date of Installation:
Name of Installer:
Signature of Installer:
This product has been tested, certified and listed to the requirements
ofASME/ANSI A112.19.8-2007, ASME/ANSI A112.19.8a-
2008, ASME/ANSI A112.19.8b-2009 and APSP-16-2011 per §1404 ofthe Virginia Graham Baker (VGB 2008) Pool and Spa
Safety Act. Certified by: Underwriters Laboratories, Inc., 2929 E. Imperial Highway, Suite 100, Brea, CA 92821-6729
This product is certified to comply with §1404 of the Virginia
Graham Baker (VGB 2008) Pool and Spa Safety Act. A copy of the
test results for the above may be found at www.waterwayplastics.com or go to: www.ul.com. This product is manufactured
by Waterway Plastics, Oxnard CA 93030
Designed,
, ,waterway._
Engineered &
Manufactured
2200 Fast Sturgis Road Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403
in the USA,
waterway@waterwayplastics.com • www.waterwayplastirs.com
02020eaur aynanw
1110-0253.0320
GRATE AND FRAME OWNER'S MANUAL
For Model Number: 640-4720(12" x 12")
IN WARNING
Read and keep these instructions for future reference. Follow all instructions in this
2008 A owner's manual and on the equipment. Failure to follow instructions can cause severe
injury and/or death.
IMPORTANT SAFETY INSTRUCTIONS
WARNING - SUCTION ENTRAPMENT HAZARD
,� Suction in suction outlets and/or suction outlet
covers which are damaged, broken, cracked,
missing, or unsecured can cause severe injury and/
or death due to the following entrapment hazards;
Hair Entrapment: Hair can become entangled in suction outlet cover.
Limb Entrapment: A limb inserted into an opening of suction outlet
sump or suction outlet cover that is damaged, broken, cracked, missing,
or not securely attached can result in a mechanical bind or swelling of
the limb.
Body Suction Entrapment: A negative pressure applied to a large
portion of the body or limbs can result in an entrapment.
Evisceration / Disembowelment Entrapment: A negative pressure
applied directly to the intestines through an unprotected suction
outlet sump or suction outlet cover which is damaged, broken, cracked,
missing, or unsecured can result in evisceration / disembowelment
entrapment.
Mechanical Entrapment: There is potential forjewelry, swimsuit,
hair decorations, finger, toe, or knuckle to be caught in an opening of a
suction outlet cover resulting in mechanical entrapment.
TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:
n� • Use two or more suction fitting on each
lul pump suction line. The suction fittings
shall be separated by a minimum of 3 ft.
O� (91.44 cm), or if any are located closer they
shall be located on two different planes
(i.e., one on the bottom and one on the vertical wall, or one each on
two separate vertical wall).
In the event of one suction outlet being completely blocked, the
remaining suction outlets serving that system shall have a flow
rating capable of the full flow of the pump(s) for the specific suction
system.
Dual suction fittings shall not be located on seating areas or on the
backrest for such seating areas.
The maximum system flow rate shall not exceed the flow rating of
any listed (per ASME Al 12.19.8-2007) suction outlet cover installed.
In the event of one suction outlet being completely blocked, the
remaining suction outlets serving the system shall have a flow rating
capable of the full flow of the pump(s).
• Never use a pool or spa if any suction outlet component is damaged,
broken, cracked, missing, or not securely attached.
• Replace damaged, broken, cracked, missing, or not securely attached
suction outlet components immediately.
• Two or more suction outlets per pump should be installed in
accordance with latest APSP Standards and CPSC guidelines, and
follow all National, State, and Local codes applicable.
• Replace the suction within 7 years from the installation date.
• Installation of a vacuum release system, which relieves entrapping
suction, is recommended.
USE ONLY GENUINE SUPER PRO REPLACEMENT PARTS.
Screws
Grat1
Gra« Flame
Head Loss Curve -12" x 12"
3S
3
23
s 2
e
$ 13
1
as
0
0 SO Mo ISO 200 2% 300 350 000 4S0 500
Flow Rate (GPM)
®2018 Waterway Plastics
Head Lou Curve - 9" x 9"
6
S
0
3
a 2
1
0
0 SO 100 ISO 200 250 300 Ho 400
Now Rate (GPM)
810-0213.0618
WARNING
AFailure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction
outlets can result in an increased potential for suction entrapment as described on the previous page.
AFailure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material,
can result in an increased potential for suction entrapment as described on the previous page.
ASuction outlet components have a finite life. The cover/grate should be inspected frequently and replaced at
least every seven years, or if found to be damaged, broken cra
cked, asked, missing, or not securely attached.
AThe 12" x 12" fitting is rated at 356 GPM for floor and 280 GPM for wall. If the fitting is missing or broken,
replace with a fitting of equivalent rating or higher. Use of a lower rated suction fitting could result in
entrapment of the body which could result in serious injury including drowning.
ADo not use or operate pool, spa, or hot tub if this suction fitting is missing, broken or not secured per
instructions. The suction fitting is intended to prevent entrapment of the body. Use of the spa hot tub with a
missing, broken or improperly secured suction grate may result in serious personal injury including drowning.
AWhen the pool, spa or hot tub is in operation, suction is created at this fitting. Users of the spa or hot tub must
be instructed not to come in contact with this fitting in such a way as to block its orifice. If a user of the spa or
hot tub blocks this fitting with his/her body, serious personal injury or drowning may occur.
®In order to remove the suction cover (for service or winterization), using a Phillips -head screw driver remove
the screws. Inspect both the suction cover and suction fitting for any cracks or damages.
AIt is imperative to securely attach the suction cover to the wall fittings (use only the original supplied screws
or obtain original replacements). Do not over tighten the screws. Inspection of fasteners and observation for
damaged/tampered with suction fittings is required.
®Any and all broken or missing parts must be replaced prior to starting spa or pool pump. Never operate spa or
pool without drain cover in place and properly affixed, death or serious injury can result.
ADo not exceed the safe flow rate. Do not increase flow through system by increasing pump size or horsepower.
ADo not allow children to sit, play or interact with main drains or suction outlet.
102018 Waterway Plastics
810-0213.0618
INSTRUCTIONS FOR THE USE OF FIELD BUILT SUMPS
A
D min.
G
GENERAL NOTES:
(a) D = inside diameter of pipe.
(b) All dimensions shown are minimums.
(c) A broken line L _ J indicates suggested sump configuration.
FIELD BUILT SUMP
B
J
D min.
The design of field fabricated sumps shall be further specified by a Registered Design Professional so as to fully address
the considerations of cover/grate loadings, durability, hair, finger, and limb entrapment issues, as well as features
particular to the site.
LIMITED WARRANTY
Waterway Plastics manufactures its products and equipment in accordance with very high standards of workmanship. We use the best materials
available and maintain the highest quality procedures practical in the industry. For Warranty, product must be registered at time of purchase/installation
at www.waterwayplastics.com. For Warranty claims or questions, please contact point of purchase,
Super*nra CR)
genuine replacement parts
Designed,
Engineered by % / /
Manufacturedd /
in the USA.
waterway-M
02020 Waterway Plastics
810-0213-SG.0320