Loading...
HomeMy WebLinkAboutAPPROVED DH Window 14593.4 Non-HVHZ 2/18/2021 Florida Building Code Online Business & Professional Regulation BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr a Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail �OFFICEOFTHE FL# FL14593-R6 SECRETARY Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Jim Flesher Address/Phone/Email 10030 Bavaria Rpad Fort Myers, FL 33913 (800)432-2204 jflesher@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Double Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/1.5.2/A440 2011 ASTM E 1886 2012 ASTM E 1996 2012 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14593 R6 Equiv FL14593 AAMA EQ,pdf FL14593 R6 Equiv FL14593 ASTM EQ,pdf Product Approval Method Method 1 Option A https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquxTVBjriRcYkPrfmOgmnVChlYilAkOiSFTJ9jYLGgmhg%3d%3d 1/3 2/18/2021 Florida Building Code Online Date Submitted 10/24/2020 Date Validated 10/26/2020 Date Pending FBC Approval Date Approved 11/02/2020 Summary of Products FL# Model,Number or Name Description 14593.1 Series 1531 Non-Impact Vinyl Double Series 1531 Non-Impact Vinyl Double Hung Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14593 R6 C CAC NIO10606-R3.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 02/28/2024 Design Pressure: +50/-50 Installation Instructions Other: Maximum Size: 48"x 72" Nailing Fin Installation. FL14593 R6 II 08-00560B.pdf Frame material to be rigid PVC from Deceuninck North America Verified By: Luis R. Lomas, P.E. 62514 AAMA Certified (DEP-1) Created by Independent Third Party: Yes Evaluation Reports FL14593 R6 AE 510949A.pdf Created by Independent Third Party: Yes 14593.2 Series 1541 Non-Impact Vinyl Double Series 1541 Non-Impact Vinyl Double Hung Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14593 R6 C CAC NIO10606.01-R3.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2024 Design Pressure: +50/-50 Installation Instructions Other: Maximum Size: 47 1/2"x 71 1/2" Flange Installation. FL14593 R6 II 08-00621B.pdf Frame material to be rigid PVC from Deceuninck North America Verified By: Luis R. Lomas, P.E. 62514 AAMA Certified (DEP-1) Created by Independent Third Party: Yes Evaluation Reports FL14593 R6 AE 511004B.pdf Created by Independent Third Party: Yes 14593.3 Series 2551 Impact Vinyl Double Series 2551 Impact Vinyl Double Hung Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14593 R6 C CAC NIO10606-R3.pdf Approved for use outside HVHZ: Yes FL14593 R6 C CAC NIO10628-R2.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 02/28/2024 Other: Maximum Size: 48"x 72" Nailing Fin Installation. Installation Instructions Frame material to be rigid PVC from Deceuninck North America FL14593 R6 II 08-00566B.pdf AAMA Certified (DEP-1) Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14593 R6 AE 510955A.pdf Created by Independent Third Party: Yes 14593.4 Series 2561 Impact Vinyl Double Series 2561 Impact Vinyl Double Hung Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14593 R6 C CAC NIO10606.01-R3.pdf Approved for use outside HVHZ:Yes FL14593 R6 C CAC NIO10629-R2.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 09/30/2024 Other: Maximum Size: 48"x 72" Flange Installation. Frame Installation Instructions material to be rigid PVC from Deceuninck North America AAMA FL14593 R6 II 08-00620B.pdf Certified(DEP-1) Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14593 R6 AE 511005B.pdf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquxTVBjriRcYkPrfmOgmnVChlYilAkOiSFTJ9jYLGgmhg%3d%3d 2/3 2/18/2021 Florida Building Code Online provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® in ® E Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquxTVBjriRcYkPrfmOgmnVChlYilAkOiSFTJ9jYLGgmhg%3d%3d 3/3 NOTICE OF PRODUCT CERTIFICATION to CERTIFIcq,.o pCrk iL �OfT,r+ CERTIFICATION NO: NI010606.01-113 ® DATE: 05/09/2011 N 1 CERTIFICATION PROGRAM: Structural COMPANY: Eastern 7`'�FsreHY►�' `� CODE: 1783-1 EDP REVISION DATE: 03/03/2020 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series "1541/2561" 16341 Domestic Avenue Vinyl Double Hung Window Ft. Myers, FL 33912 w/Flange Configuration:X/X Glazing:Insulating Glass(Annealed) Frame: W-1206mm(47.5") H-1816mm(71.5") Sash: W-1127mm(44.38") H-908mm(35.75") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-05 H-R50 1206 x 1816 (48 x 72 Product Tested By: Architectural Testing, Inc. Report No: 77631.06-501-47 Expiration Date: October 31, 2024 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION to CERTIFIcq,.o pCrk iL �OfT,r+ CERTIFICATION NO: NI010629-R2 ® DATE: 05/13/2011 N 1 CERTIFICATION PROGRAM: Structural COMPANY: Eastern 7`'�FsreHY►�' `� CODE: 1783-1 EDP REVISION DATE: 03/03/2020 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series "2561" Impact Rated 16341 Domestic Avenue Vinyl Double Hung Window Ft. Myers, FL 33912 w/Flange Configuration:X/X Glazing:IG-1/8"Annealed Glass/ Laminate-1/8"Annealed Glass/0.090"PVB by Solutia/ 1/8"Annealed Glass Frame: W-1219mm(48") H-1829mm(72") Sash: W-1130mm(44.5") H-914mm(36") SPECIFICATION PRODUCT RATING ASTM E1886-02/E1996-02 Design Pressure: +50/-50 psf Wind Zone 4-Missile Level D Product Tested By: Certified Testing Laboratories. Report No: CTLA-2062W-7 Expiration Date: September 30, 2024 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd. Lewisville,NC 27023 Report No.: 511OO5B 434-688-0609 rllomas@lrlomaspe.com Manufacturer: Eastern Architectural Systems 16341 Domestic Ave. FT Myers, FL 33912 Product Line: 2561 Double Hung Window Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-00620 Revision B, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test Report No.: CTLA-2062W-7 signed and sealed by Ramesh Patel, P.E. Certified Testing Laboratories, Orlando, FL. ASTM E1886/E1996 Large Missile Impact Test, Level D,Wind Zone 4 Cyclic Load Test, ±50.0 psf design pressure 3. Test Report No.:ATI 77631.06-501-47 signed by Lynn George Architectural Testing, Springdale, PA. AAMA/WDMA/CSA 101/I.S.2/A440 Design pressure: ±50.16psf Water penetration resistance 7.52psf 4. Anchor calculations, report number 511005-1A, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ±50.Opsf • Maximum unit size: 48"x 72" • Units must be glazed per ASTM E 1300 see installation instructions for glass details. • This product is not rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • PVC profiles certified by AAMA Deceunick North America DEP-1 and VBP-2 Installation: Units must be installed in accordance with approval document, 08-00620 Revision B. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s)for which this report is being issued.Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). ��o R I+L EN Zz -4 0151 TAPE OF • 00 . �: FS:c�0RMt-. �•�'�� okw 1 of 1 Luis R. Lomas, P.E. FL No.: 62514 10/19/2020 REVISIONS REV DESCRIPTION DATE APPROVED A MANUFACTURER'S NAME CHANGE 03/04/09 R.L. B REVISED INSTALLATION DETAILS 06/19/15 R.L. NOTES: 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE REQUIREMENTS OF THE FLORIDA BUILDING CODE. DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. ALL FASTENERS TO BE CORROSION RESISTANT. TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 17. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN 3. 1 X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1 -1/2" WINDOW UNITS MUST BE A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 18. UNITS MAY BE INSTALLED WITH OR WITHOUT ADD-ON FLANGE. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1 X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/1 6" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11 . FRAME MATERIAL: EXTRUDED RIGID PVC. 12, UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS OPTIONS. 13. APPROVED 48" X 72" PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED: 0612212015 EASTERN RN ARCHITECTURAL SYSTEMS 1 ���� A DIVISION OF ■ - - - EASTERN METAL SYPPLY \��\5 R• L 0��y"�i�� /� ALUMINUM ANO ViNVL 16341 DOMESTIC AVE �� J • •'� FORT MYERS,FLORIDA 33912 ••��E Ns�•�,% 800-032-2204 \ Nv TABLE OF CONTENTS 2561 DOUBLE HUNG - LMI =* D51 • yt SHEET N0. DESCRIPTION 48" X 72" -r � NOTES ,-1 • TAT OF - 1 NOTES DRAWN: DWG NO. REV ��0��•;AC0R1OP•.��� 2 ELEVATION A.M. DATE 08 s00620 B ss/QNAL•��G�\\ 3 4 INSTALLATION DETAILS NTS 7/29/08 1 OF 4 <<IIII� �j REVISIONS REV DESCRIPTION DATE APPROVED 48" MAX FRAME WIDTH A MANUFACTURER'S NAME CHANGE 03/04/09 R.L. 6" MAX 17 MAX 1 O.C. 6" MAX B REVISED INSTALLATION DETAILS 06/19/15 R.L. 6" MAX O 8 1/2" / 3/4" MAX O.C. 1/8" ANN. 72" / 1/8" ANN. MAX / FRAME .090" PVB BY EASTMAN HEIGHT / 1/8" ANN. / SETTING X EXTERIOR BLOCK 1/2" BITE INTERIOR 6" MAX GLAZING DETAIL 154112561 VINYL DOUBLE HUNG WINDOW EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING ±50.OPSF LARGE MISSILE IMPACT SIGNED: 0612212015 EASTERN ARCHITECTURAL SYSTEMS NOTES: '• Eastern EASTERN MIETOAL SYPPLY �`\\S11111 R, L/O//��/ 1 . MAXIMUM SASH SIZE: 44 3/8" X 35 3/4" ■ 16341 DOMESTIC AVEFORT MYER \�`\� • ' ' ' ALUMINUM ANO VINYL v • • 9 /� 2. MAXIMUM D.L.O.: 43 50" X 34 1/4" " 8 0432-2204S,FLORIDA33912 ` • ENS •Lp 2561 DOUBLE HUNG - LMI = *4- TAT �51 48" X 72" ELEVATION � OF •«�; i0 . DRAWN: DWG NO. REV A. 08 s00620 B //S�01VAL,�����\ NTS DATE 7/29/08 2 OF 4 141 7/16" MIN. REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED WOOD FRAMING A MANUFACTURER'S NAME CHANGE 03/04/09 R.L. OR 2X BUCK B REVISED INSTALLATION DETAILS 06/19/15 R.L. BY OTHERS 1 1/4" MIN. EMBEDMENT BACKER ROD a 1/4" MAX. 1 1/4" MIN. /4" MAX. & APPROVED SHIM SPACE EMBEDMENT SHIM SPACE SEALANT INTERIOR 7/16" MIN. EDGE DISTANCE D #8 WOOD SCREW O 0 0 00 #8 WOOD SCREW a a WOOD FRAMING O INTERIOR OR 2X BUCK ° BY OTHERS EXTERIOR EXTERIOR BACKER ROD & APPROVED SEALANT Q JAMB INSTALLATION DETAIL O Q SILL TO BE SET WOOD FRAMING OR 2X BUCK INSTALLATION IN A BED OF APPROVED SEALANT BACKER ROD & APPROVED 1/4" MAX. SEALANT SHIM SPACE NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. WOOD FRAMING 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE OR 2X BUCK DESIGNED IN ACCORDANCE WITH ASTM E2112 BY OTHERS SIGNED: 0612212015 VERTICAL CROSS SECTION EASTERN ARCHITECTURAL SYSTEMS WOOD FRAMING OR 2X BUCK INSTALLATION �� EASTERN METAL SYPPLY ���\�j1 R• L�0 / - -�Eastern � ���'y"" ■ 16341 DOMESTIC AVE \\``\• • • • • :1 111 A LUMINIJM ANO VINYL �/ CC A� • w...o: w•«oow. •«o 000ww FORT MYERS,FLORIDA 33912 \ • `• GIY • -n .ti 800-432-2204 ` ♦ \\ SF •y. ' 2561 DOUBLE HUNG - LMI _*4- TAT 0�51 48" X 72" INSTALLATION DETAILS � OF DRAWN: DWG NO. REV I \ � '��• � OR10P•� � A.M. 08-00620 B /�s tONAL SCALE NTS DATE 7/29/08 SHEET3 OF 4 2 1/2" MIN. REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY ° ° A MANUFACTURER'S NAME CHANGE 03/04/09 R.L. BY OTHERS B REVISED INSTALLATION DETAILS 06/19/15 R.L. 1 1/4" MIN. OPTIONAL 1 X BUCK EMBEDMENT „ 1 1/4" MIN. 1/4 MAX. SEE NOTES 3 — 7 SHEET 1 EMBEDMENT SHIM SPACE CONCRETE/MASONRY a BY OTHERS ° BACKER ROD ° & APPROVED 1/4" MAX. a SEALANT SHIM SPACE INTERIOR OPTIONAL 1 X BUCK ° SEE NOTES 3 7 ° a 3/16" TAPCON SHEET 1 a v 0 D Qv 3/16" TAPCON a ° a v a 0 EXTERIOR n 0 2 1/2" ° uL Ll MIN. a a INTERIOR EDGE DISTANCE a O v v ° v v BACKER ROD EXTERIOR & APPROVED SEALANT O SILL TO BE SET JAMB INSTALLATION DETAIL N A BED OF BACKER ROD APPROVED SEALANT CONCRETE/MASONRY INSTALLATION & APPROVED NOTES: SEALANT 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, 1/4" MAX. NOT SHOWN FOR CLARITY. OPTIONAL 1 X BUCK SHIM SPACE 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SEE NOTE 3 — 7 DESIGNED IN ACCORDANCE WITH ASTM E2112 SHEET 1 CONCRETE/MASONRY BY OTHERS SIGNED: 0612212015 ° ° ° ° 4 °Q d ° ° EASTERN AA DIVISION O L SYSTEMS a d °, .. ° ° d. ° ° ■ Eastern EASTERN METAL SYPPLY \\��\� R,• L 0/�I��j ° 16341 DOMESTIC AVE V A •Y/� 8 ° ALUMINUM n�NOU von ows FORT MYERS,FLORIDA 33912 �` �• �• EI / / 'b.° .•. 800-432-2204 ` : � � •• ' 2561 DOUBLE HUNG - LMI _*• 0�51 48" X 72" INSTALLATION DETAILS � • TAT OF VERTICAL CROSS SECTION 0�.� ,A�oR,�P \etc\\ CONCRETE/MASONRY INSTALLATION DRAWN: DWG NO. REV Imo' .• • . . sAcAM DATE 08 s00620 B �� IONAI.IE�G��\ NTS 7/29/08 4 OF 4 �IIIII