Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RAMOS RESIDENCE Builder Name: Street: 1071 S. HEADER CANAL ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(3494.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2920.00 ft2 b. Frame - Wood, Adjacent R=13.0 574.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (3337.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3337.00 ft2 6. Conditioned floor area above grade (ft2) 3337 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows (588.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 140 a. U-Factor: Sgl, U=0.65 364.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 130 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 224.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft2 b. Central Unit 23.6 SEER:16.00 SHGC: ft Area Weighted Average Overhang Depth: 13.017 . 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.269 a. Electric Strip Heat 27.0 COP:1.00 b. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (3337.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3337.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.176 Total Proposed Modified Loads: 100.51 PASS Total Baseline Loads: 103.99 1 hereby certify that the plans and specifications covered by Review of the plans and t this calculation are in compliance with the Florida Energy specifications covered by this 4V Code. calculation indicates compliance G'00 with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 3-9-2021A this building will be inspected for compliance with Section 553.908 ��IRE $rAT I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes. C7 ��i,�p� �.�`�•••�` OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 8 FORM R405-2020 INPUT 5UMMAKY CHECKLIST REPORT PROJECT Title: RAMOS RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3337 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 1071 S. HEADER CANA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1877 20329 2 AHU 2 1460 16604 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 MASTER BEDROO 375 4125 No 0 1 1 Yes Yes Yes 2 M W IC 2 96 960 No 0 1 No Yes Yes 3 M W IC 1 55 550 No 0 1 No Yes Yes 4 M TOILET 20 200 No 0 1 No Yes Yes 5 M HALL 16 160 No 0 1 No Yes Yes 6 PANTRY 75 750 No 0 1 No Yes Yes 7 STORAGE CLST 30 300 No 0 1 No Yes Yes 8 ENTRY HALL 24 240 No 0 1 No Yes Yes 9 LAUNDRY 64 640 No 0 1 Yes Yes Yes 10 DINING RM 180 2160 No 0 1 Yes Yes Yes 11 FOYER 96 1440 No 0 1 Yes Yes Yes 12 OFFICE 210 2520 No 0 1 Yes Yes Yes 13 LIVING ROOM 368 4784 No 0 1 Yes Yes Yes 14 FAMILY RM 412 4944 No 0 1 Yes Yes Yes 15 KITCHEN 350 3500 Yes 0 1 No Yes Yes 16 CLST 2 16 160 No 0 1 Yes Yes Yes 17 BEDROOM 2 176 1760 No 0 1 1 Yes Yes Yes 18 WIC 3 25 250 No 0 1 No Yes Yes 19 BATH 2 25 250 No 0 1 No Yes Yes 20 BEDROOM 3 186 1860 No 0 1 1 Yes Yes Yes 21 BATH 4 42 420 No 0 1 Yes Yes Yes 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8 FORM R405-2020 INPUT 5UMMAKY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 BATH 3 42 420 No 0 1 No Yes Yes 23 BEDROOM 4 186 1860 No 0 1 1 Yes Yes Yes 24 WIC 4 36 360 No 0 1 Yes Yes Yes 25 HALLWAY 52 520 No 0 1 Yes Yes Yes 26 M BATH 180 1800 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 36 ft 375 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation M W IC 2 1 ft 96 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation M W IC 1 1 ft 55 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulation M TOILET 1 ft 20 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation M HALL 1 ft 16 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation PANTRY 1 ft 75 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation STORAGE CLST 1 ft 30 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation ENTRY HALL 1 ft 24 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation LAUNDRY 8 ft 64 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation DINING RM 23 ft 180 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation FOYER 8 ft 96 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation OFFICE 23 ft 210 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation LIVING ROOM 20 ft 368 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation FAMILY RM 41 ft 412 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation KITCHEN 1 ft 350 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation CLST 2 2 ft 16 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 2 26 ft 176 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation WIC 3 1 ft 25 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation BATH 2 1 ft 25 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulation BEDROOM 3 14 ft 186 ft2 ---- 1 0 0 21SIab-On-Grade Edge Insulation BATH 4 6 ft 42 ft2 ---- 1 0 0 22SIab-On-Grade Edge Insulation BATH 3 1 ft 42 ft2 ---- 1 0 0 23SIab-On-Grade Edge Insulation BEDROOM 4 33 ft 186 ft2 ---- 1 0 0 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 24SIab-On-Grade Edge Insulation WIC 4 12 ft 36 ft2 ____ 1 0 0 25SIab-On-Grade Edge Insulation HALLWAY 9 ft 52 ft2 ____ 1 0 0 26SIab-On-Grade Edge Insulation M BATH 1 ft 180 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3731 fe 0 ft2 Medium N 0.3 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3337 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 0 Blown 375 ft2 0.1 Wood 2 Under Attic (Unvented) M W IC 2 0 Blown 96 ft2 0.1 Wood 3 Under Attic (Unvented) M W IC 1 0 Blown 55 ft2 0.1 Wood 4 Under Attic (Unvented) M TOILET 0 Blown 20 ft2 0.1 Wood 5 Under Attic (Unvented) M HALL 0 Blown 16 ft2 0.1 Wood 6 Under Attic (Unvented) PANTRY 0 Blown 75 ft2 0.1 Wood 7 Under Attic (Unvented) STORAGE CLST 0 Blown 30 ft2 0.1 Wood 8 Under Attic (Unvented) ENTRY HALL 0 Blown 24 ft2 0.1 Wood 9 Under Attic (Unvented) LAUNDRY 0 Blown 64 ft2 0.1 Wood 10 Under Attic (Unvented) DINING RM 0 Blown 180 ft2 0.1 Wood 11 Under Attic (Unvented) FOYER 0 Blown 96 ft2 0.1 Wood 12 Under Attic (Unvented) OFFICE 0 Blown 210 ft2 0.1 Wood 13 Under Attic (Unvented) LIVING ROOM 0 Blown 368 ft2 0.1 Wood 14 Under Attic (Unvented) FAMILY RM 0 Blown 412 ft2 0.1 Wood 15 Under Attic (Unvented) KITCHEN 0 Blown 350 ft2 0.1 Wood 16 Under Attic (Unvented) CLST 2 0 Blown 16 ft2 0.1 Wood 17 Under Attic (Unvented) BEDROOM 2 0 Blown 176 ft2 0.1 Wood 18 Under Attic (Unvented) WIC 3 0 Blown 25 ft2 0.1 Wood 19 Under Attic (Unvented) BATH 2 0 Blown 25 ft2 0.1 Wood 20 Under Attic (Unvented) BEDROOM 3 0 Blown 186 ft2 0.1 Wood 21 Under Attic (Unvented) BATH 4 0 Blown 42 ft2 0.1 Wood 22 Under Attic (Unvented) BATH 3 0 Blown 42 ft2 0.1 Wood 23 Under Attic (Unvented) BEDROOM 4 0 Blown 186 ft2 0.1 Wood 24 Under Attic (Unvented) WIC 4 0 Blown 36 ft2 0.1 Wood 25 Under Attic (Unvented) HALLWAY 0 Blown 52 ft2 0.1 Wood 26 Under Attic (Unvented) M BATH 0 Blown 180 ft2 0.1 Wood 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belowo Space 1 S Exterior Concrete Block - Int InsuMASTER BE 4.1 11 0 11 0 121.0 ft2 0 0 0.3 0 2 W Exterior Concrete Block - Int InsuMASTER BE 4.1 25 0 11 0 275.0 ft2 0 0 0.3 0 3 S Garage Frame - Wood MASTER BE 13 4 0 11 0 44.0 ft2 0 0.1 0.3 0 4 E Garage Frame - Wood M W IC 2 13 6 0 10 0 60.0 ft2 0 0.1 0.3 0 5 S Garage Frame - Wood M W IC 2 13 16 0 10 0 160.0 ft2 0 0.1 0.3 0 6 E Garage Frame - Wood M W IC 1 13 11 0 10 0 110.0 ft2 0 0.1 0.3 0 7 S Garage Frame - Wood M W IC 1 13 1 0 10 0 10.0 ft2 0 0.1 0.3 0 8 E Garage Frame - Wood M TOILET 13 4 0 10 0 40.0 ft2 0 0.1 0.3 0 9 S Garage Frame - Wood STORAGE C 13 3 0 10 0 30.0 ft2 0 0.1 0.3 0 10 S Garage Frame - Wood ENTRY HALL 13 4 0 10 0 40.0 ft2 0 0.1 0.3 0 11 E Exterior Concrete Block - Int Insul LAUNDRY 4.1 8 0 10 0 80.0 ft2 0 0 0.3 0 12 S Garage Frame - Wood LAUNDRY 13 8 0 10 0 80.0 ft2 0 0.1 0.3 0 13 N Exterior Concrete Block - Int InsulDINING RM 4.1 2 0 12 0 24.0 ft2 0 0 0.3 0 14 E Exterior Concrete Block - Int InsulDINING RM 4.1 15 0 12 0 180.0 ft2 0 0 0.3 0 15 S Exterior Concrete Block - Int InsulDINING RM 4.1 6 0 12 0 72.0 ft2 0 0 0.3 0 16 E Exterior Concrete Block - Int Insul FOYER 4.1 8 0 15 0 120.0 ft2 0 0 0.3 0 17 N Exterior Concrete Block - Int Insul OFFICE 4.1 6 0 12 0 72.0 ft2 0 0 0.3 0 18 E Exterior Concrete Block - Int Insul OFFICE 4.1 15 0 12 0 180.0 ft2 0 0 0.3 0 19 S Exterior Concrete Block - Int Insul OFFICE 4.1 2 0 12 0 24.0 ft2 0 0 0.3 0 20 W Exterior Concrete Block - Int InsuLIVING ROO 4.1 20 0 13 0 260.0 ft2 0 0 0.3 0 21 N Exterior Concrete Block - Int InsulFAMILY RM 4.1 21 0 12 0 252.0 ft2 0 0 0.3 0 22 W Exterior Concrete Block - Int InsulFAMILY RM 4.1 20 0 12 0 240.0 ft2 0 0 0.3 0 23 E Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 10 0 20.0 ft2 0 0 0.3 0 24 N Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.3 0 25 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 14 0 10 0 140.0 ft2 0 0 0.3 0 26 N Exterior Concrete Block - Int InsuBEDROOM 3 4.1 14 0 10 0 140.0 ft2 0 0 0.3 0 27 N Exterior Concrete Block - Int Insul BATH 4 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 28 N Exterior Concrete Block - Int InsuBEDROOM 4 4.1 15 0 10 0 150.0 ft2 0 0 0.3 0 29 S Exterior Concrete Block - Int InsuBEDROOM 4 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 30 W Exterior Concrete Block - Int InsuBEDROOM 4 4.1 12 0 10 0 120.0 ft2 0 0 0.3 0 31 S Exterior Concrete Block - Int Insul WIC 4 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 32 W Exterior Concrete Block- Int Insul WIC 4 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 33 S Exterior Concrete Block - Int Insul HALLWAY 4.1 9 0 10 0 90.0 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated ENTRY HALL None .23 2 8 8 21.3 ft2 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Single Yes 0.65 0.3 Y 48.0 ft2 14 ft 0 in 1 ft 4 in None None 2 W 2 Metal Low-E Single Yes 0.65 0.25 Y 24.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 3 W 2 Metal Low-E Single Yes 0.65 0.25 Y 72.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 4 E 11 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 14 Metal Low-E Single Yes 0.65 0.25 Y 36.0 ft2 10 ft 0 in 1 ft 4 in None None 6 E 16 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 7 E 16 Metal Low-E Single Yes 0.65 0.3 Y 48.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 8 E 18 Metal Low-E Single Yes 0.65 0.25 Y 36.0 ft2 10 ft 0 in 1 ft 4 in None None 9 W 20 Metal Low-E Single Yes 0.65 0.3 Y 128.0 ft2 30 ft 0 in 1 ft 4 in None None 10 N 21 Metal Low-E Single Yes 0.65 0.25 Y 45.0 ft2 16 ft 0 in 1 ft 4 in None None 11 W 22 Metal Low-E Single Yes 0.65 0.25 Y 24.0 ft2 10 ft 0 in 1 ft 4 in None None 12 W 22 Metal Low-E Single Yes 0.65 0.25 Y 40.0 ft2 10 ft 0 in 1 ft 4 in None None 13 E 25 Metal Low-E Single Yes 0.65 0.25 Y 18.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 14 N 26 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 15 W 30 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1750 ft2 1750 ft2 57 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000351 3077.8 168.85 317.01 .1027 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 2 Central Unit/ None Single SEER: 16 23.6 kBtu/hr 708 cfm 0.8 2 sys#2 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Prop. Leak Free Attic --- cfm 56.3 cfm 0.03 0.50 1 1 2 Attic 6 130 ft2 Attic 13 ft2 Prop. Leak Free Attic --- cfm 43.8 cfm 0.03 0.50 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Mar Apr May Jun Oct Nov Dec Jan Feb H H Mar Jun rl Jul Aug rj �XjSep Oct Nov �A Dec VentinHeating Jan Feb lxJ Mar Apr May lX� Jun ]] Jul Aug Sep Oct xJ Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ftz ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ftz ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ftz ft 0.3 M BATH 3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 8 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.