HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: RAMOS RESIDENCE
Builder Name:
Street: 1071 S. HEADER CANAL ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(3494.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2920.00 ft2
b. Frame - Wood, Adjacent
R=13.0 574.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (3337.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 3337.00 ft2
6. Conditioned floor area above grade (ft2) 3337
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows (588.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 140
a. U-Factor: Sgl, U=0.65 364.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 130
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 224.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
29.4 SEER:16.00
c. U-Factor: N/A ft2
b. Central Unit
23.6 SEER:16.00
SHGC:
ft Area Weighted Average Overhang Depth: 13.017 .
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Strip Heat
27.0 COP:1.00
b. Electric Strip Heat
17.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (3337.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 3337.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.176 Total Proposed Modified Loads: 100.51
PASS
Total Baseline Loads: 103.99
1 hereby certify that the plans and specifications covered by
Review of the plans and
t
this calculation are in compliance with the Florida Energy
specifications covered by this
4V
Code.
calculation indicates compliance
G'00
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 3-9-2021A
this building will be inspected for
compliance with Section 553.908
��IRE $rAT
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
Florida Statutes.
C7 ��i,�p� �.�`�•••�`
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 8
FORM R405-2020 INPUT 5UMMAKY CHECKLIST REPORT
PROJECT
Title:
RAMOS RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3337
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
1071 S. HEADER CANA
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1877
20329
2
AHU 2
1460
16604
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfllID Finished Cooled
Heated
1
MASTER BEDROO
375
4125 No
0
1
1
Yes
Yes
Yes
2
M W IC 2
96
960 No
0
1
No
Yes
Yes
3
M W IC 1
55
550 No
0
1
No
Yes
Yes
4
M TOILET
20
200 No
0
1
No
Yes
Yes
5
M HALL
16
160 No
0
1
No
Yes
Yes
6
PANTRY
75
750 No
0
1
No
Yes
Yes
7
STORAGE CLST
30
300 No
0
1
No
Yes
Yes
8
ENTRY HALL
24
240 No
0
1
No
Yes
Yes
9
LAUNDRY
64
640 No
0
1
Yes
Yes
Yes
10
DINING RM
180
2160 No
0
1
Yes
Yes
Yes
11
FOYER
96
1440 No
0
1
Yes
Yes
Yes
12
OFFICE
210
2520 No
0
1
Yes
Yes
Yes
13
LIVING ROOM
368
4784 No
0
1
Yes
Yes
Yes
14
FAMILY RM
412
4944 No
0
1
Yes
Yes
Yes
15
KITCHEN
350
3500 Yes
0
1
No
Yes
Yes
16
CLST 2
16
160 No
0
1
Yes
Yes
Yes
17
BEDROOM 2
176
1760 No
0
1
1
Yes
Yes
Yes
18
WIC 3
25
250 No
0
1
No
Yes
Yes
19
BATH 2
25
250 No
0
1
No
Yes
Yes
20
BEDROOM 3
186
1860 No
0
1
1
Yes
Yes
Yes
21
BATH 4
42
420 No
0
1
Yes
Yes
Yes
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8
FORM R405-2020 INPUT 5UMMAKY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22
BATH 3 42
420
No 0
1 No
Yes
Yes
23
BEDROOM 4 186
1860
No 0
1
1 Yes
Yes
Yes
24
WIC 4 36
360
No 0
1 Yes
Yes
Yes
25
HALLWAY 52
520
No 0
1 Yes
Yes
Yes
26
M BATH 180
1800
No 0
1 No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation MASTER BEDRO
36 ft
375 ft2
----
1
0
0
2 Slab -On -Grade Edge Insulation
M W IC 2
1 ft
96 ft2
----
1
0
0
3 Slab -On -Grade Edge Insulation
M W IC 1
1 ft
55 ft2
----
1
0
0
4 Slab -On -Grade Edge Insulation
M TOILET
1 ft
20 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulation
M HALL
1 ft
16 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulation
PANTRY
1 ft
75 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulation STORAGE
CLST
1 ft
30 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation
ENTRY HALL
1 ft
24 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulation
LAUNDRY
8 ft
64 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation
DINING RM
23 ft
180 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
FOYER
8 ft
96 ft2
----
1
0
0
12SIab-On-Grade Edge Insulation
OFFICE
23 ft
210 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
LIVING ROOM
20 ft
368 ft2
----
1
0
0
14SIab-On-Grade Edge Insulation
FAMILY RM
41 ft
412 ft2
----
1
0
0
15SIab-On-Grade Edge Insulation
KITCHEN
1 ft
350 ft2
----
1
0
0
16SIab-On-Grade Edge Insulation
CLST 2
2 ft
16 ft2
----
1
0
0
17SIab-On-Grade Edge Insulation
BEDROOM 2
26 ft
176 ft2
----
1
0
0
18SIab-On-Grade Edge Insulation
WIC 3
1 ft
25 ft2
----
1
0
0
19SIab-On-Grade Edge Insulation
BATH 2
1 ft
25 ft2
----
1
0
0
20SIab-On-Grade Edge Insulation
BEDROOM 3
14 ft
186 ft2
----
1
0
0
21SIab-On-Grade Edge Insulation
BATH 4
6 ft
42 ft2
----
1
0
0
22SIab-On-Grade Edge Insulation
BATH 3
1 ft
42 ft2
----
1
0
0
23SIab-On-Grade Edge Insulation
BEDROOM 4
33 ft
186 ft2
----
1
0
0
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
24SIab-On-Grade
Edge Insulation
WIC 4 12 ft
36 ft2
____
1 0 0
25SIab-On-Grade
Edge Insulation
HALLWAY 9 ft
52 ft2
____
1 0 0
26SIab-On-Grade Edge Insulation
M BATH 1 ft
180 ft2
____
1 0 0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul. (deg)
1
Hip Composition shingles 3731 fe
0 ft2
Medium
N
0.3
No 0.9
No 20 26.57
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
3337 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
MASTER BEDRO
0
Blown
375 ft2
0.1
Wood
2
Under Attic (Unvented)
M W IC 2
0
Blown
96 ft2
0.1
Wood
3
Under Attic (Unvented)
M W IC 1
0
Blown
55 ft2
0.1
Wood
4
Under Attic (Unvented)
M TOILET
0
Blown
20 ft2
0.1
Wood
5
Under Attic (Unvented)
M HALL
0
Blown
16 ft2
0.1
Wood
6
Under Attic (Unvented)
PANTRY
0
Blown
75 ft2
0.1
Wood
7
Under Attic (Unvented)
STORAGE CLST
0
Blown
30 ft2
0.1
Wood
8
Under Attic (Unvented)
ENTRY HALL
0
Blown
24 ft2
0.1
Wood
9
Under Attic (Unvented)
LAUNDRY
0
Blown
64 ft2
0.1
Wood
10
Under Attic (Unvented)
DINING RM
0
Blown
180 ft2
0.1
Wood
11
Under Attic (Unvented)
FOYER
0
Blown
96 ft2
0.1
Wood
12
Under Attic (Unvented)
OFFICE
0
Blown
210 ft2
0.1
Wood
13
Under Attic (Unvented)
LIVING ROOM
0
Blown
368 ft2
0.1
Wood
14
Under Attic (Unvented)
FAMILY RM
0
Blown
412 ft2
0.1
Wood
15
Under Attic (Unvented)
KITCHEN
0
Blown
350 ft2
0.1
Wood
16
Under Attic (Unvented)
CLST 2
0
Blown
16 ft2
0.1
Wood
17
Under Attic (Unvented)
BEDROOM 2
0
Blown
176 ft2
0.1
Wood
18
Under Attic (Unvented)
WIC 3
0
Blown
25 ft2
0.1
Wood
19
Under Attic (Unvented)
BATH 2
0
Blown
25 ft2
0.1
Wood
20
Under Attic (Unvented)
BEDROOM 3
0
Blown
186 ft2
0.1
Wood
21
Under Attic (Unvented)
BATH 4
0
Blown
42 ft2
0.1
Wood
22
Under Attic (Unvented)
BATH 3
0
Blown
42 ft2
0.1
Wood
23
Under Attic (Unvented)
BEDROOM 4
0
Blown
186 ft2
0.1
Wood
24
Under Attic (Unvented)
WIC 4
0
Blown
36 ft2
0.1
Wood
25
Under Attic (Unvented)
HALLWAY
0
Blown
52 ft2
0.1
Wood
26
Under Attic (Unvented)
M BATH
0
Blown
180 ft2
0.1
Wood
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Belowo
Space
1
S
Exterior
Concrete Block - Int InsuMASTER BE
4.1
11
0
11
0
121.0 ft2
0
0
0.3
0
2
W
Exterior
Concrete Block - Int InsuMASTER BE
4.1
25
0
11
0
275.0 ft2
0
0
0.3
0
3
S
Garage
Frame - Wood MASTER BE
13
4
0
11
0
44.0 ft2
0
0.1
0.3
0
4
E
Garage
Frame - Wood M W IC 2
13
6
0
10
0
60.0 ft2
0
0.1
0.3
0
5
S
Garage
Frame - Wood M W IC 2
13
16
0
10
0
160.0 ft2
0
0.1
0.3
0
6
E
Garage
Frame - Wood M W IC 1
13
11
0
10
0
110.0 ft2
0
0.1
0.3
0
7
S
Garage
Frame - Wood M W IC 1
13
1
0
10
0
10.0 ft2
0
0.1
0.3
0
8
E
Garage
Frame - Wood M TOILET
13
4
0
10
0
40.0 ft2
0
0.1
0.3
0
9
S
Garage
Frame - Wood STORAGE C
13
3
0
10
0
30.0 ft2
0
0.1
0.3
0
10
S
Garage
Frame - Wood ENTRY HALL
13
4
0
10
0
40.0 ft2
0
0.1
0.3
0
11
E
Exterior
Concrete Block - Int Insul LAUNDRY
4.1
8
0
10
0
80.0 ft2
0
0
0.3
0
12
S
Garage
Frame - Wood LAUNDRY
13
8
0
10
0
80.0 ft2
0
0.1
0.3
0
13
N
Exterior
Concrete Block - Int InsulDINING RM
4.1
2
0
12
0
24.0 ft2
0
0
0.3
0
14
E
Exterior
Concrete Block - Int InsulDINING RM
4.1
15
0
12
0
180.0 ft2
0
0
0.3
0
15
S
Exterior
Concrete Block - Int InsulDINING RM
4.1
6
0
12
0
72.0 ft2
0
0
0.3
0
16
E
Exterior
Concrete Block - Int Insul FOYER
4.1
8
0
15
0
120.0 ft2
0
0
0.3
0
17
N
Exterior
Concrete Block - Int Insul OFFICE
4.1
6
0
12
0
72.0 ft2
0
0
0.3
0
18
E
Exterior
Concrete Block - Int Insul OFFICE
4.1
15
0
12
0
180.0 ft2
0
0
0.3
0
19
S
Exterior
Concrete Block - Int Insul OFFICE
4.1
2
0
12
0
24.0 ft2
0
0
0.3
0
20
W
Exterior
Concrete Block - Int InsuLIVING ROO
4.1
20
0
13
0
260.0 ft2
0
0
0.3
0
21
N
Exterior
Concrete Block - Int InsulFAMILY RM
4.1
21
0
12
0
252.0 ft2
0
0
0.3
0
22
W
Exterior
Concrete Block - Int InsulFAMILY RM
4.1
20
0
12
0
240.0 ft2
0
0
0.3
0
23
E
Exterior
Concrete Block - Int Insul CLST 2
4.1
2
0
10
0
20.0 ft2
0
0
0.3
0
24
N
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
12
0
10
0
120.0 ft2
0
0
0.3
0
25
E
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
14
0
10
0
140.0 ft2
0
0
0.3
0
26
N
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
14
0
10
0
140.0 ft2
0
0
0.3
0
27
N
Exterior
Concrete Block - Int Insul BATH 4
4.1
6
0
10
0
60.0 ft2
0
0
0.3
0
28
N
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
15
0
10
0
150.0 ft2
0
0
0.3
0
29
S
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
6
0
10
0
60.0 ft2
0
0
0.3
0
30
W
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
12
0
10
0
120.0 ft2
0
0
0.3
0
31
S
Exterior
Concrete Block - Int Insul WIC 4
4.1
6
0
10
0
60.0 ft2
0
0
0.3
0
32
W
Exterior
Concrete Block- Int Insul WIC 4
4.1
6
0
10
0
60.0 ft2
0
0
0.3
0
33
S
Exterior
Concrete Block - Int Insul HALLWAY
4.1
9
0
10
0
90.0 ft2
0
0
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated ENTRY HALL
None
.23
2
8
8
21.3 ft2
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Ornt
ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
S
1 Metal
Low-E Single
Yes
0.65 0.3 Y
48.0 ft2 14 ft 0 in
1 ft 4 in
None
None
2
W
2 Metal
Low-E Single
Yes
0.65 0.25 Y
24.0 ft2 2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
3
W
2 Metal
Low-E Single
Yes
0.65 0.25 Y
72.0 ft2 2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
4
E
11 Metal
Low-E Single
Yes
0.65 0.25 Y
12.0 ft2 2 ft 0 in
1 ft 4 in
None
None
5
E
14 Metal
Low-E Single
Yes
0.65 0.25 Y
36.0 ft2 10 ft 0 in
1 ft 4 in
None
None
6
E
16 Metal
Low-E Single
Yes
0.65 0.25 Y
12.0 ft2 12 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
7
E
16 Metal
Low-E Single
Yes
0.65 0.3 Y
48.0 ft2 12 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
8
E
18 Metal
Low-E Single
Yes
0.65 0.25 Y
36.0 ft2 10 ft 0 in
1 ft 4 in
None
None
9
W
20 Metal
Low-E Single
Yes
0.65 0.3 Y
128.0 ft2 30 ft 0 in
1 ft 4 in
None
None
10
N
21 Metal
Low-E Single
Yes
0.65 0.25 Y
45.0 ft2 16 ft 0 in
1 ft 4 in
None
None
11
W
22 Metal
Low-E Single
Yes
0.65 0.25 Y
24.0 ft2 10 ft 0 in
1 ft 4 in
None
None
12
W
22 Metal
Low-E Single
Yes
0.65 0.25 Y
40.0 ft2 10 ft 0 in
1 ft 4 in
None
None
13
E
25 Metal
Low-E Single
Yes
0.65 0.25 Y
18.0 ft2 2 ft 0 in
1 ft 4 in
Drapes/blinds
None
14
N
26 Metal
Low-E Single
Yes
0.65 0.25 Y
30.0 ft2 2 ft 0 in
1 ft 4 in
Drapes/blinds
None
15
W
30 Metal
Low-E Single
Yes
0.65 0.25 Y
15.0 ft2 2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
1750 ft2
1750 ft2
57 ft
loft
13
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse
Proposed ACH(50)
.000351
3077.8 168.85 317.01 .1027
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COP:1
17 kBtu/hr
2
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
29.4 kBtu/hr 882 cfm
0.8 1
sys#1
2
Central Unit/
None
Single SEER: 16
23.6 kBtu/hr 708 cfm
0.8 2
sys#2
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98
50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
---- Supply----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat
Cool
1 Attic
6 140 ft2
Attic
14 ft2
Prop. Leak Free
Attic
--- cfm
56.3 cfm 0.03
0.50
1
1
2 Attic
6 130 ft2
Attic
13 ft2
Prop. Leak Free
Attic
--- cfm
43.8 cfm 0.03
0.50
2
2
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan Feb
Mar
Apr
May
Jun
Oct
Nov
Dec
Jan Feb
H H
Mar
Jun rl Jul
Aug
rj
�XjSep
Oct Nov
�A
Dec
VentinHeating
Jan Feb
lxJ Mar
Apr
May
lX� Jun ]] Jul
Aug
Sep
Oct xJ
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9 10
11
12
Cooling (W D) AM
78
78 78
78
78 78
78
78
80 80
80
80
PM
80
80 80
80
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78 78
78
78 78
78
78
80 80
80
80
PM
80
80 80
80
78 78
78
78
78 78
78
78
Heating (WD) AM
65
65 65
65
65 65
65
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
65
65 65
65
65 65
65
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STORAGE CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ftz
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH 4
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ftz
ft
0.3
WIC 4
Default(8 Ibs/sq.ft.
ftz
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ftz
ft
0.3
M BATH
3/8/2021 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 8
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.