Loading...
HomeMy WebLinkAboutBUILDING PLANDocuSign Envelope ID: 92EDA28E-CB24-4D08-A531-C8E6A6818852 HB N WALL LEGEND ID DESCRPTION SPECS THICKNESS ON FLOOR PLAN REINFORCED CMU WALL W/ FINISHES SEE TYP WALL SECTION 9" REINFORCED CMU WALL WO/ INT FINISH SEE TYP WALL SECTION 8^ REINFORCED CMU COLUMN SEE FLOOR PLAN VARIES NON LOAD BEARING INT WALL SEE PROJECT SPECS ON A-1 4.5" LOAD BEARING 2x4 WALL NONE PRESENT 4.5" rL_VVm PL_HLV FLOOR PLAN NOTES: 1. INTERIOR DIMENSIONS ARE TO FINISH. SEE WALL LEGEND FOR THICKNESS. 2. EXTERIOR DIMENSIONS ARE TO STRUCTURE. FLOOR PLAN KEYNOTES: 1. 22"x30" RO MIN ATTIC ACCESS 2. 3. TYP REAR/SIDE PORCH BEAM- CASTCRETE 8F16-1B/2T. 10' TOB. 4. TYP FRONT PORCH BEAM- CASTCRETE 8F20-1B/2T. 12' TOB. 5. TYP PORCH COLUMN- 12"x12"x8" CMU, 4 #5 VERT, #3 TIE @ 16" OC. 6. STAIR HANDRAIL PER FBC-R 311.7.8.2, PORCH GURADRAIL PER FBC-R 312 7. COLUMN- 8"x16" RCC, 4 #5 VERT, #3 TIE @ 8" OC. PROJECT SPECS: 1. INTERIOR NON LOADBEARING WALLS: 1/2" OR 5/8" GWB OVER 3-5/8" 25 GA METAL STUD OR 2x4 @ 16" OC. 2. PORCH CEILING: STUCCO & LATH OVER FRAMING OR PINE T&G PER GEN NOTE 34. 3. INSULATION: EXT WALLS: R4.1 FOIL INSULATION. R20 SPRAYFOAM @ CONDITINED ROOF DECK, & ATTIC SEPARATING KNEE WALLS @ PORCHES & GARAGES. R-13 BATT @ GARAGE SEPARATING WALL, FLOOR TO CLG. PROVIDE ACCESS HATCH TO CONNECT ATTIC SPACES. 4. DEFFERED SUBMITTALS: ROOF TRUSSES, SITE PLAN, DUCT LAYOUT, RAILINGS SHEET INDEX A-1 floor plan A-2 foundation plan A-3 elevs A-4 elect, plumb A-5 HVAC GN-1 general notes PROJECT DESCRIPTION NEW 1 STORY SF RESIDENCE. ZONING INFORMATION: parcel id: 2214-501-0004-000-9 AG-5 (St Lucie County) flood zone: X UTILITY INFORMATION: gas: n/a sewage: septic potable water: well AREA CALCULATIONS: conditioned living area 3,337 sf garage 914 sf covered rear porch 742 sf covered side porch 139 sf covered front porch 303 sf total building area 5,435 sf conditioned volume 34,327 cf ID D1 PRESSURESACTUAL D. 38.4,41.8 6-0 DOOR/ 8-0 LINTEL SCHEDULE DESCRIPTION CC 8F8-1B D. SWING, GLAZED D2 34.1,-37.9 9-0 10-0 CC 8F24-113/1T SECTIONAL OVERHEAD D3 34.1,-37.9 9-0 10-0 CC 8F24-1B/1T SECTIONAL OVERHEAD D4 34.1,-37.9 9-0 10-0 CC 8F24-1B/1T SECTIONAL OVERHEAD D5 38.4,-41.8 2-6 8-0 CC 8RF22-1B/1T S. SWING, UNGLAZED D6 38.4,-41.8 6-0 8-0 CC 8RF22-16/1T D. SWING, GLAZED D7 38.4,-41.8 16-0 8-0 CC 8F24-1B/2T 4 PANEL SGD SEE GEN NOTE 26. CC: CAST CRETE. WINDOW/ ACTUAL D. ID PRESSURES W H W1 40.2,-43.6 3-0 6-0 LINTEL 8-0 LINTEL SCHEDULE LINTEL TYPE NOTES CC 8F24-1B/1T S.HUNG EGRESS W2 40.2,-43.6 (2) 3-0 6-0 8-0 CC 8F24-113/1T (2) S. HUNG W3 40.2,-43.6 (2) 3-0 6-0 8-0 CC 8F24-113/1T (2) S. HUNG W4 40.2,-43.6 3-0 4-0 8-0 CC 8F24-113/1T CASEMENT W5 40.2,-43.6 2-4 6-0 7-4 CC 8F24-113/1T S.HUNG W6 40.2,-43.6 3-0 6-0 7-4 CC 8F24-113/1T S.HUNG W7 40.2,-43.6 2-4 6-0 7-4 CC 8F24-16/1T S.HUNG W8 40.2,-43.6 4-6 5-2 7-4 CC 8F24-113/1T S.HUNG W9 40.2,-43.6 4-6 5-2 7-4 CC 8F24-1B/1T S.HUNG W10 40.2,-43.6 6-0 6-0 8-0 CC 8F24-113/1T H. SLIDER MULLED FIXED BELOW W10.1 40.2,-43.6 6-0 2-0 8-0 CC 8F24-16/1T FIXED W11 40.2,-43.6 6-0 6-0 8-0 CC 8F24-113/1T H. SLIDER MULLED FIXED BELOW W11.1 40.2,-43.6 6-0 2-0 8-0 1 CC 8F24-1B/1T FIXED W12 40.2,-43.6 3-0 5-2 8-0 CC 8F24-113/1T S.HUNG EGRESS W13 40.2,-43.6 2-8 5-2 8-0 CC 8F24-16/1T S.HUNG EGRESS W14 40.2,-43.6 2-8 5-2 8-0 CC 8F24-113/1T S.HUNG W15 40.2,-43.6 4-0 5-2 8-0 CC 8F24-16/1T S.HUNG MULLED FIXED BELOW W15.1 40.2,-43.6 4-0 2-10 8-0 CC 8F24-113/1T FIXED W16 40.2,-43.6 4-0 5-2 8-0 CC 8F24-16/1T S.HUNG MULLED FIXED BELOW W16.1 40.2,-43.6 4-0 2-10 8-0 CC 8F24-113/1T FIXED W17 40.2,-43.6 3-0 5-2 8-0 CC 8F24-16/1T S.HUNG W18 40.2,-43.6 3-0 5-2 8-0 CC 8F24-113/1T S.HUNG W19 40.2,-43.6 3-0 5-2 8-0 j CC 8F24-1B/1T S.HUNG W20 40.2,-43.6 6-0 2-0 11-0 CC 8F12-1B HEAD CC 8F8-1B SILL FIXED SEE GEN NOTE 26. CC: CAST CRETE. co ~ 0 E O C = O N O It CD tL dMLf) E-0 Q + QC8 't m 0 C V (D m 4)Q M 0 ai j_o—N M I- N �' O CN 0 C O M M C J co LL LL U 0 U w O a U LL U w IL U) x r O W 0 w o_ O J ' ^ W W � V / Z Q rn V/ LU W J 0 W CM W ' U LL W Q W Z U W W �+ W [if W L Z Z U W W U W Q }� � Z Z � J J O LL Z Lu W 5 W 0 J L LL O Cn LL W W a 0 a U W W Q Q w v) W C6F- N W 2 Z 0 0 Z W Q U 0 O Z Z W LU w z Q 0 Z Q U) Z Q J a ui Z 0 U) w 0 ui w 0 J Q Q Z W O U W Q floor plan 3/28/20 SHEET A-1 EDocuSigned by: �V'a,In,� E935FAF30E92486— 3/28/2021 OF FAO �.eN0S P. Il AR97108 SCALE: 1/4"= V-0" DocuSign Envelope ID: 92EDA28E-CB24-4D08-A531-C8E6A6818852 FOOTING SCHEDULE •• TYPE SIZE (WxLxH) HEIGHT REINFORCEMENTID • F1 STEM WALL 24"xCONTx12" DETAIL (3) #5 CONT BOT (3) #5 CONT BOT, #5 F1.1 STEM WALL 32"xCONTx12" DETAIL TRANSV @ 24" OC SIM TO F1 F2 STEM WALL 24"KONTx24" DETAIL (3) #5 CONT BOT F3 STEM WALL 24"xCONTx24" DETAIL (3) #5 CONT BOT F4 SOG, MONO 20"xCONTx20" DETAIL (2) #5 CONT BOT F5 ISOG, MONO 20"xCONTx20" DETAIL (2) #5 CONT BOT ruw4w ► L iuim rL_iAim i 0" D p p p p p p —GO •p p ° p ° p p p STEM WALL PER TYP WALL SECTION F1 @ RECESS/SWR F1 SEE TYP WALL SECTION STEM WALL PER WALL SECT 8" OVERPOUR W/ (1) #5 CONT i �f24� F2 .UMN BEYOND TO ,R ON FTG, NOT OVERPOUR SLOPE CJ/EJ J 8" OVERPOUR W/ (1) #5 CONT O STEM WALL PER TYP WALL SECTION p ° ° s OPT CJ/EJ II �I F4 F5 1' MIN UM p #4 @ EA NOSE p ' #4 @ 12" OC TRANS ° #4 @ 12" OC BOTT 2 END WALL OF STEPS: 6" THICK W/ #4 @ 12" OC TYP STAIR ON GRADE HORIZ BOND BEAM STEEL CONT BAR TO MATCH HORIZ OR CORNER BARS W/ 25" LAP MIN D ° p D p ° p p T p p COURSE/STEEL QTY/SIZE PER SPECS, ° D USE BEAM OR KNCKOUT BLOCK p p p ° p p p p p CMU WALL HORIZ BOND BEAM STEEL SECTION ELEVATION CHANGE- ELEVATION VIEW p I • ° p ° ° O ° p p D q ° CORNER BAR W/ 25" LAP MIN d °° TO MATCH HORIZ SIZE, QTY Ip l° HORIZ STEEL INTERSECTION- PLAN VIEW CORNER- PLAN VIEW BOND BEAM/ LINTEL CONTINUITY DETAILS SCALE: NTS CAST-CRETE LINTEL DIAGRAM F = FILLED WITH GROUT / U = UNFILLED QUANTITY OF #5 FIELD ADDED REBAR AT BOTTOM OF U-LINTEL CAVITY FOR GRAVITY LOAD U 16-1 BM T NOMINAL WIDTH � L QUANTITY OF #5 FIELD REBAR AT TOP OF NOMINAL HEIG2ADDED NOMINAL HEIGHT COMPOSITE U-LINTEL FOR UPLIFT LOAD #5 FIELD ADDED REBAR AT TOP OF COMPOSITE U - LINTEL MIN. (1) REQ'D ° 1-1/2" CLEAR H a 2 w FIELD PLACED C.M.U. 2 ed a � Q J Z °a i'n p GROUT N � Z � a #5 FIELD ADDED REBAR AT BOTTOM OF U-LINTEL CAVITY BOTTOM REINFORCING 7-5/8" ACTUAL YYY PROVIDED IN U-LINTEL 8" NOMINAL WIDTH (SEE REINFORCING SCHEDULE) LINTEL AS PER WINDOW/DOOR SCHEDULE D p DOOR & WINDOW BUCK AS PER GEN NOTE 26.2 FLASHING AND SEALING AS PER GEN NOTE 26.7 WINDOW FRAME W/ FLANGE, ATTACH TO MASONRY/CONC AS PER MFR SPECS HiWind MASONRY SILL BY CASTCRETE EXT p ° INT p p p TYP OPENING BUCK DETAIL SCALE: 1 "= V-0" FOUNDATION NOTES: -SEE GEN NOTES 17.2 FOR DOWEL LOCATIONS. FILLED WALL CELLS ARE MARKED ON PLAN FOR CLARIFICATION. -SEE FLOOR PLAN FOR DIMENSIONS FOUNDATION KEYNOTES: 1. TYP FILLED CELL c� [` CD E E O t� C = 0N0'� cn tL r d c Ln E-0 Q + IZ8 C m 2 4) Q M W 0 ai v G —N --a' coX I-- N � 0 CD 0 C _j M C J � � LL U 0 U w O d U_ W U w IL U) U) 2 F of O 0 w d O J w w 0 z Q rn V/ LU W J O Ww M' W U LL_ Q W Z LU U W w w [if w L a ZU W W a V) W Q i o J J O LL. m Z LU W 5 W J L W LL cn LL_ - o- W O w a O a U W F w ZQ — i a� F- QW L A/ VJ U) w co ^1 W F- W 2Z O Z n v / W Q U I� 0 W z O Z W LU W Z Q Z Q U Z J a U) Z 0 U) LD 0 U) Q w J J Q Q Z W O W Q 0 foundation plan 3/28/20 SHEET A-2 DocuSigned by: �V'aan,� E935FAF3OE92486... 3/28/2021 OF FAO C1S P. L/, e`& AR97108 SCALE: 1/4"= V-0" DocuSign Envelope ID: 92EDA28E-CB24-4D08-A531-C8E6A6818852 LEFT ELEVATION SCALE: 3/16"= V-0" CONNECTION (CXN) SCHEDULE TRUSS ACTUAL ACTUAL CONNECTED ELEMENTS All truss to bond beam locations uno REACTION• UPLIFT truss GRAVITY CONNECTOR• CO-1 valley truss to ea supporting truss truss CO-6 or CO-7 truss AG3 P truss CO-8 truss AG4 truss C0-8 truss AG5 truss CO-8 truss AG6 truss CO-8 truss G2 M truss 1 1 C0-8 truss G3 truss I CO-9 truss G6 truss I CO-10 1. Connector ID references the connector (CO) schedule. 2. All loads are checked by architect, loads left blank were checked but are not required to be listed. 3. Actual loads listed in this schedule are worst case, actual may be lower than listed but never higher. 4. If 'connected elements' contains 'truss', reference loads in truss package. If no reaction points specified use connector for all nesessary points. FRONT ELEVATION SCALE: 3/16"= V-0" CONNECTOR (CO) SCHEDULE ALLOW ALLOW ID CONNECTED ELEMENTS UPLIFT GRAVITY CITY MFR MODEL CO-1 see CXN sched 1810 1 Simpson HETA 20 To truss w/ (9) 10d x 1.5" CO-2 see CXN sched 2035 2 Simpson HETA 20 To single ply truss w/ (10) 10d x 1.5" CO-3 see CXN sched 2500 2 Simpson HETA 20 To multi ply truss w/ (12) 16d To conc w/ (4) .25" x 2.25" tapcon. To truss w/ (10) CO-4 missed or misplaced co-1 1175 1 Simpson HTSM20 10d x 1.5" To conc w/ (4) .25" x 2.25" tapcon. To truss w/ (10) CO-5 missed or misplaced co-1 2350 2 Simpson HTSM20 10d x 1.5" To valley truss be w/ (3) 10d x 1.5". To supporting CO-6 see CXN sched 370 1 Simpson VTCR truss tc w/ (4) 10d. To valley truss be w/ (4) 10d x 1.5". To supporting CO-7 see CXN sched 500 1 Simpson MST12 truss tc w/ (4) 10d x 1.5. To truss w/ (22) 10d nails. To conc w/ 5/8" TR epoxied CO-8 see CXN sched 3965 1 Simpson MGT 12" into bond beam. To truss w/ (16) 10d. To conc w/ (2) 3/4" TR epoxied CO-9 see CXN sched 10980 1 Simpson HGT2 12" into bond beam. To truss w/ (16) 10d. To conc w/ (2) 3/4" TR epoxied CO-10 see CXN sched 10530 1 Simpson HGT3 12" into bond beam. 1. Refer to connection CXN schedule for connector locations. 2. 'QTY' referes to the number of connectors used per per ea connection (connected elements). If qty left blank, refer to drawings. RIGHT ELEVATION SCALE: 3/16"= V-0" W RB 024" ALUM OR CU Z COUNTER FLASHING 4"x4" MIN .024" ALUM OR CU L SIDEWALL FLASHING ROOF COVERING z 2 UNDERLAYMENT ROOF SHEATHING HEADWALL FLASHING DETAIL $ 10' WRB 024" ALUM OR CU Z COUNTER FLASHING 4'W" MIN .024" ALUM OR CU L SIDEWALL FLASHING UNDERLAYMENT z ROOF SHEATHING SIDEWALL FLASHING DETAIL -3'4" AVG GRADE SLOPE PER ELEV A. SHINGLES OVER PEEL/STICK OVER 5/8" CDX PLY OVER PE WOOD ROOF TRUSS AS PER FRAMING PLAN. PE TRUSS PER FRAMING PLANS - INSULATION PER PROJECT SPECS SEE FRAMING PLANS OR CONNECTOR SCHEDULE METAL DRIP OVER PT WOOD DRIP OVER 2x6 CEDAR FASCIA TO TRUSS ENDS W/ 2' 1 (2) #16d NAIL, 4" TRUSS HEEL STUCCO & LATH PER GEN NOTE 34 OVER ° FRAMING W/ NO VENTS EXCEPT WHERE SPECIFIED ON ATTIC VENT CALC. LINTELS PER DOOR/WINDOW/LINTEL SCHEDULE STUCCO OVER 8x8x16 CMU W/ #5 VERT REBAR @ 48" OC- 1/2" OR 5/8" GWB OVER OVER 3/4" FURRING STRIP. GARAGE WALLS TO BE UNINSULATED & UNFINISHED. WALL REINF PER GEN NOTE 16.8. DOWELS 1L SEE BRG LEGEND & ELEVATIONS 1/2" OR 5/8" GWB OVER WOOD PE TRUSS BC. CONT CMU BOND BEAM TOP (2) COURSES W/ #5 REBAR EA COURSE PROJECT SPECS: A-1 GENERAL NOTES: GN-1 PER GEN NOTE 17.2 SOG/FILL/COMPCTION PER FOUNDATON PLAN AND 8"x8" THICKNED EDGE W/ (1) CONT #5 GENERAL NOTES 0. eo v STEM WALL: 8x8x16 CMU W/ #5 VERT t REBAR @ 48" OC, FILL ALL CELLS GRADE PER SITE PLAN TYP WALL SECTION SCALE: 1/2"= V-0" ° 24" F1 c� ~ 0 E O v — U N O c = C O N p I' CD Q cn tL d co Lf) E _0 Q + QC8 't C m 2 V m Q M W m O ai j_o—Nz•9 .� M N O �. CN 0 C O M M C J CU LL LL U 0 U w O a U LL U w EL U) x r O w 0 w d O J ' ^ W W � V / z Q rn V/ Lu W J 0 Ww CM W ' C) Q w Z Lu U W W w [if w V 0 i z Z U U W W a W Q �+ L z 0 J J O LL z z C� Lu W W 0 J w 0 LL o- w lio W o- 0 _ja n v U w x � w Q Zi ^, W F- Q ~ w A/ U) w_ Co W 2 z 0 0 ZQ w U 0 W O z z W 2 r w O z Q 0 z Q U) z J a ui z 0 U) w 0 ui Q w 0 J J Q Q Z W O U LU Q elevs 3/28/20 SHEET A-3 DocuSigned by: �V'aan,� E935FAF3OE92486... 3/28/2021 OF FAO 0S, P. L/, e`& AR97108 REAR ELEVATION SCALE: 3/16"= V-0" ROOF PLAN SCALE:NTS DocuSign Envelope ID: 92EDA28E-CB24-4D08-A531-C8E6A6818852 E5 UJ W L N W I I I I I I I I I I I I I L2 E-CU E2 ` I \ I \ E- OHLU `\ W DOOR \ w \ I v = w W w w W W SS E2 L1 \ \ I \ \ I \ \ C I \ I A v I A v L12 EX I \ I � I I I L1 Q\ -a vL1 L1----- - - - - -- L1 E1 \ E-AHU ATTIC \ I f�� W PANEL B _ Ij I' 7 L9� L13 w ELECT PLAN SCALE: 3/16"= 1'-0" ELECT PLAN LEGEND E1 120V DUPLEX RECEPTACLE E2 120V GFCI DUPLEX RECEPTACLE E3 120V RECEPTACLE recessed for tv, w/ tv cable E3.1 120V GFCI RECEPTACLE recessed for tv, w/ tv cable E4 120V GFCI DUPLEX RECEPTACLE- @ soffit E5 120V GFCI DUPLEX RECEPTACLE w/ water protected box E6 240V RECEPTACLE- gene backfeed w/ panel lockout E7 120V RECEPTACLE- floor fv w/ owner E- ELECTRIC FOR LABLED APPLIANCE L1 RECESSED CAN LIGHT L2 FLUSH MOUNT CLG LIGHT L3 FLUSH LED STRIP LIGHT L4 VANITY WALL LIGHT L5 SHOP LIGHT L6 CHANDELIER LIGHT L7 PENDANT LIGHT L8 UNDER CABINET LIGHT L9 EXTERIOR WALL SCONCE L10 WALL MOUNT READING LIGHT L11 EXTERIOR MOTION DETECTOR LIGHT W/ CAMERA L12 RECESSED CAN LIGHT- wet location L13 RECESSED CAN LIGHT- exterior soffit S LIGHT SWITCH EX EXHAUST FAN- vent to roof if vented soffit, soffit if unvented EXL EXHAUST FAN WITH LIGHT- vent to roof if vented soffit, soffit if unvented FL FAN/ LIGHT COMBO FA FAN W/O LIGHT JB JUNCTION BOX SD SMOKE/CO2 DETECTOR- interconnected, hardwired w/battery T\/ TCI C\/ICIOAI r AQI C L13 II �I Ge --L---------� ---- --- L1 I I I I I I I I I I III IL1-------� � I I I L1 L7 L1 E1 I I E2 I L1 w E1 E1 a w w W L6 + E2 L1 w w -----II L1 L1 I 11 L4------------ I I � DR WA L6 C14 o tl El FA w E1 i L6 E1 E L13 � i i I E E1 L6----- L1 L1 L4 - E1 -- - w ` w � I OS- - - - - - - - - - - - - - - - - - - -j --- - - -,� -- ---� ------------------ L FRONT L13 _ \ --- - - - - -- L6--- - - - - -- L1 FA L1 Cu SWR 4_. ' IE E-AHU \ L1 ATTIC i EX E-WELL I - - _ _ SWR ( ., E� PUMP F l L1 L1----------------------L1 ❑ I I I I I I I I E-HR�OD L1 L7 L11 M I I I I I E-GD L6 E-DW I �E2 I I i L1 L1 o L7 L1 ' E1 (2)E-OV L1 L1 LU / W I / � d Q � w Q - E1 w M L13 ELECT PLAN NOTES: 1. SEE GENERAL NOTES 27 ON GN-1. 2. GFI PER PLAN & GEN NOTE 27.4. INCLUDING ALL RECEPTACLES IN LAUNDRY ROOM, WASHER, DISHWASHER, GARAGE DOOR OPENER. 3. PROVIDE DISCONNECTS FOR WATER HEATER, CU, AHU 4. ALL 120 VOLT BRANCH CIRCUITS SUPPLYING RECEPTACLES INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT (NEC 210.12(B)). NEW METER O Qm N U t U J N J f6 co f0 0- CL 0- Q �C �o �o GEC TO CWP, LIFER, INTERSYSTEM NEW UNDERGROUND WIRE SIZE BY ELECTRICAL CONTRACTOR ELECTRICAL RISER DIAGRAM SCALE: N.T.S. Electric Load Calculation SD SD - / 220.12 General Lighting Load 3 va/fe of floor area, including unused space adaptable for future use. Floor Area = 3337 ft2 10,011 va Basement Floor Area = ft2 - va 220.52(A) Small Appliance Load 1500 va for each 20 amp branch circuit required per 210.1(C)(1) in EACH kitchen, pantry, breakfast room, dining room, or similar areas. # of Small Appliance Branch Circuits =0' 1500 va = 3,000 va 220.52(B) Laundry Load # of Laundry Branch Circuits =0" 1500 va = 1,500 va Total General Lighting & Appliance Load= 14,511 va 220.42 Lighting Load Feeder Demand Factors First 3000 or less at i00% 3,000 va From 3001 to 220,000 at 35% 4,029 va Remainder over 120,000 at 25% - va Total Lighting Demand Load= 7,029 va 220.54 Electric Clothes Dryers Qty 1 Electric Dryer #1 5 00 kw 5,000 w Qty0 Electric D er #2 kw w 220.55 Electric Cooking -Ranges, Stove Tops and Wall Ovens Qty kw Qty kw Qty kw Electric Cooking Demand Load= 10,400 w 220.51 Fixed Electric Space Heating Loads or Air Conditioning Load: Fixed Electric Space Heat #a 10.0 kw AC#i/Geo 16 SEER 3 Ton 3.6 kva Fixed Electric Space Heat #2 10.0 kw AC#2/Geo 16 SEER 3 Ton 3.6 kva Fixed Electric Space Heat #3 - kw AC#3/Geo - kva Fixed Electric Space Heat #4 kw AC#4/Geo kva Fixed Electric Space Heat #5 kw AC#5/Geo kva Total Heat & AC Load = 27,240 va 220.14 Appliance load --Dwelling Units Qty Description va(watts) Qty Description va(watts) ------------ 1 Electric Cooktop Nameplate 8.00 1 Wall Oven Nameplate 8.00 o - 1 Water Heater 4,500 1 Dishwasher 1,200 1 Refrigerator 1,440 1 Microwave 1,580 0 0 0 0 0 0 0 0 o - 0 Total Connected Appliance Load = 8,720 va 220.53 Appliance load --Dwelling Units Total Appliance Demand Load = 6,540 va 220.50 Motor Loads @ 120 Volts city Description va(watts) Qty Description va(watts) 2 3/4hpPool/Spa Pump 563 1 1/2hpGarbage Disposa 375 31/2hpGar/DoorOpener 375 o - 0 0 0 0 Total Motor Load = 2,626 va 430.24 Several Motors or a Motor(s) and Other Load(s) 25 % of Largest Motor Load = 141 va Total Motor Demand Load = 2,767 va TOTAL CALCULATED DEMAND LOAD in Volt-amperes = 58,975 va TOTAL CALCULATED DEMAND LOAD in AMPS @120/240V 1ph3W = 246 amps EXISTING SERVICE SIZE NEW AMPS MINIMUM SERVICE SIZE 400 AMPS ✓ICE SIZE REQUESTED = 400 amps Note: Electrical contractorto verify accuracy and completeness of load calculation. HVAC specs are esitimates only. I w I I I I \FA L1 L1 L13 w L13 E1 E1 PRODUCT 1 Water Heater 4,500 1 Dishwasher 1,200 1 Refrigerator 1,440 1 Microwave 1,580 0 0 0 0 0 0 0 0 o - 0 Total Connected Appliance Load = 8,720 va 220.53 Appliance load --Dwelling Units Total Appliance Demand Load = 6,540 va 220.50 Motor Loads @ 120 Volts city Description va(watts) Qty Description va(watts) 2 3/4hpPool/Spa Pump 563 1 1/2hpGarbage Disposa 375 31/2hpGar/DoorOpener 375 o - 0 0 0 0 Total Motor Load = 2,626 va 430.24 Several Motors or a Motor(s) and Other Load(s) 25 % of Largest Motor Load = 141 va Total Motor Demand Load = 2,767 va TOTAL CALCULATED DEMAND LOAD in Volt-amperes = 58,975 va TOTAL CALCULATED DEMAND LOAD in AMPS @120/240V 1ph3W = 246 amps EXISTING SERVICE SIZE NEW AMPS MINIMUM SERVICE SIZE 400 AMPS ✓ICE SIZE REQUESTED = 400 amps Note: Electrical contractorto verify accuracy and completeness of load calculation. HVAC specs are esitimates only. I w I I I I \FA L1 L1 L13 w L13 E1 E1 PRODUCT 0 0 0 0 0 o - 0 Total Connected Appliance Load = 8,720 va 220.53 Appliance load --Dwelling Units Total Appliance Demand Load = 6,540 va 220.50 Motor Loads @ 120 Volts city Description va(watts) Qty Description va(watts) 2 3/4hpPool/Spa Pump 563 1 1/2hpGarbage Disposa 375 31/2hpGar/DoorOpener 375 o - 0 0 0 0 Total Motor Load = 2,626 va 430.24 Several Motors or a Motor(s) and Other Load(s) 25 % of Largest Motor Load = 141 va Total Motor Demand Load = 2,767 va TOTAL CALCULATED DEMAND LOAD in Volt-amperes = 58,975 va TOTAL CALCULATED DEMAND LOAD in AMPS @120/240V 1ph3W = 246 amps EXISTING SERVICE SIZE NEW AMPS MINIMUM SERVICE SIZE 400 AMPS ✓ICE SIZE REQUESTED = 400 amps Note: Electrical contractorto verify accuracy and completeness of load calculation. HVAC specs are esitimates only. I w I I I I \FA L1 L1 L13 w L13 E1 E1 PRODUCT 0 0 0 0 Total Motor Load = 2,626 va 430.24 Several Motors or a Motor(s) and Other Load(s) 25 % of Largest Motor Load = 141 va Total Motor Demand Load = 2,767 va TOTAL CALCULATED DEMAND LOAD in Volt-amperes = 58,975 va TOTAL CALCULATED DEMAND LOAD in AMPS @120/240V 1ph3W = 246 amps EXISTING SERVICE SIZE NEW AMPS MINIMUM SERVICE SIZE 400 AMPS ✓ICE SIZE REQUESTED = 400 amps Note: Electrical contractorto verify accuracy and completeness of load calculation. HVAC specs are esitimates only. I w I I I I \FA L1 L1 L13 w L13 E1 E1 PRODUCT L13 w L13 E1 E1 PRODUCT APPROVAL AFFIDAVIT DOOR OVERHEAD ALL 38,-44 N/A Clopay any FL 16107.23 DOOR S. SWING, GLAZED ALL 66,-70 N/A leldwen any FL 14569.E DOOR D. SWING, GLAZED ALL 80,-80 IMPACT ES Windows EL 300 FL 22551.1 DOOR SGD ALL 65,-65 IMPACT ES Windows EL 400 NOA 200427.11 WINDOW CASEMENT ALL 85,-85 IMPACT ES Windows 5000 NOA 200915.02 WINDOW S.HUNG ALL 60,-70 IMPACT ES Windows EL 100 FL 22250.1 WINDOW H. SLIDER ALL 65,-65 IMPACT ES Windows EL 200 NOA 201208.07 WINDOW FIXED ALL 60,-80 IMPACT ES Windows EL 150 FL 21461.1 WINDOW MULLION ALL 58.9 N/A ES Windows 1x4 custom NOA 201118.13 ROOFING UNDERLAYMENT ALL N/A N/A Soprema any FL 2569.1 ROOFING A. SHINGLES ALL N/A N/A Owens Corning any FL 10674.1 1. 'ID' as per door &window schedule, or all meaning worst case of all similar items of that type. 2. If building dp are left blank- see door &window schedule or design pressure chart. 3. This affidavit is only to verify product's compliance with wind loads. 4. Unless products are specifically submitted for verification by contractor, they are assumed. 5. If glass type is not specified more than 'impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures. 6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures. 7. I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. PLUMBING DIAGRAM SCALE: 1/8"= 1'-0" It CD I,CN LL co - LLL Cn co Co L cc ~ 0 O C =ONO Q (n DocuSigned by: �V'a,ln,� E935FAF30E92486... 3/28/2021 O AR97108 , DocuSign Envelope ID: 92EDA28E-CB24-4D08-A531-C8E6A6818852 HB a1 r BRA HB z c� ~ 0 E O E = OV C _ .o CD cn 0 - Q + Qp �— N CD m = N N m C.2 �� .N EQN oco 2) LO L 2�� — N N 0 C + r M 0 J J 0 m m LL LL U U W 0 (Z U U W a. F- O W ❑ W a O LO J W W ❑ �} ❑ Z Q /Tvim VJ ❑ W J 0 W❑ M/ > W U J L.L W Q W Z U W LU W [If W L Z U) U W W W a Q �+ L z ❑ J i- O 7 m J LL Z W 5 W J L Q ry W LL O LL- F it W O W d CU W W a- ZL W i ) V W = oc �_ W 2 Z Z W a U ❑ Z_ U F- O Z W LU W (D Z Q Q ❑ Z Q U Z Q 0- d U) Z U U W Vi Q W J Q O Z W O U Lu Q HVAC 3/28/20 SHEET A-5 Docu Signed by: �V'aanlc F935FAF3OF92486... 3/28/2021 SCALE: 1/4"= 1'-0" DocuSign Envelope ID: 92EDA28E-CB24-4D08-A531-C8E6A6818852 BASIS OF STRUCTURAL DESIGN: SOIL BEARING: 2500 psf (assumed) WIND: 160mph (ult), risk cat 2, exp C, wind borne debri region, .18 enclosed design FROST DEPTH: 12" - THE STRUCTURAL DESIGN APPROACH FOR MASONRY, ROLLED STEEL, AND LIGHT WEIGHT STEEL IS WORKING STRESS DESIGN. THE DESIGN APPROACH FOR REINFORCED CONCRETE IS ULTIMATE STRENGTH DESIGN. THE DESIGN SERVICE LOADS AREAS FOLLOWS: ROOF LIVE LOAD 20 PSF(slope<4:12) ROOF DEAD LOAD 7 PSF TC (shingles, metal, modified bitumen) ROOF WIND LOAD (SEE DRAWINGS) CEILING DEAD LOAD 10 PSF BC WALL WIND LOADS (SEE DRAWINGS) FLOOR DEAD LOADS 15 PSF TC, 5 PSF BC FLOOR LIVE LOADS SEE BELOW FLOOR LIVE LOADS: Uninhabitable attics without storage 10 psf Uninhabitable attics with limited storage 20 psf Habitable attics and attics served with fixed stairs 30 psf Balconies (exterior) and decks 40 psf Fire escapes 40 psf Guardrails and handrails 200 lb Guardrail in -fill components 50 plf Passenger vehicle garages 50 psf Rooms other than sleeping room 40 psf Sleeping rooms 30 psf Stairs 40 psf WIND PRESSURES (asd COMPONENT AND CLADDING LOADS... FROM TABLE FBC R301.2(2) ZONE EFFECTIVE WIND AREA (SF) 170 Hip Roof > 20 to 27 deg 1 10.0 30.1 -53.9 1 20.0 25.9 -47.7 1 50.0 20.5 -39.6 1 100.0 16.4 -33.4 2e, 2r, 3 10.0 30.1 -74.3 2e, 2r, 3 20.0 25.9 -66.4 2e, 2r, 3 50.0 20.5 -56.0 2e, 2r, 3 100.0 16.4 -48.1 Wall 4 10.0 40.2 -43.6 4 1 20.0 38.4 -41.8 4 50.0 36.0 -39.5 4 100.0 34.2 -37.7 4 500.0 30.1 -33.4 5 1 10.0 40.2 -53.9 5 20.0 38.4 -50.2 5 50.0 36.0 -45.5 5 100.0 34.2 -41.8 5 500.0 30.1 -33.4 Gara e g Door I 9 x7 1 35.6 1 -40.2 I 16'x7' 1 34.1 1 -37.9 1.29 adjustment factor used r O.Bh m ' -� r - � _ I r - . -1 I I o I I I I I I ICI 0 100 I I L_L I I n.Chl II I -1 I 4 - - - - J FL4N 1 i I 1 - a-�a'J w -1I L 1 3 1 E2n1 I PLAN Gahlt and Flu Ron& 7" e 8 5 49" 1 - - ­--� - r. m I h ELEVATION 6 1:: h a IE-EVAT LOIN _I .r , �& B Y 11 1I F e h 1 �I I r I I ELEVATLDH 1 �' I t I I Ir r • f• I _I , I P'L.iN HORoaft7"<8545" waft GENERAL NOTES- residential 1. CODE COMPLIANCE: 1.1. This project was designed under the following codes. The construction documents cannot reference all of the codes require for the p J 9 9 q construction of this building. By submitting these construction documents for permit or commencing work, the contractor, hereby agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing codes includingbut not limited to the most current editions as adopted b the state of Florida of the following: p Y 9 -2020 FBC: RESIDENTIAL, 7th ed -2017 NATIONAL ELECTRIC CODE -2020 FBC: ENERGY CONSERVATION, 7th ed -ASCE 7-16 2. ALL GENERAL NOTES 2.1. THE FOLLOWING SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO SUPPLEMENT THE DRAWINGS. IN CASE OF CONFLICT NOTIFY ARCHITECT. THESE DRAWINGS IN CONJUNCTION WITH OTHER SUBMITTALS REPORTS OR WRITTEN INSTRUCTIONS BY ARCHITECT OR CONSULTANTS, SHALL BE CONSIDERED THE COMPLETE CONSTRUCTION DOCUMENTS. 2.2. THE FOLLOWING GENERAL & SPECIFIC NOTES SHALL APPLY EQUALLY TO ALL CONTRACTORS, SUBCONTRACTORS, AND SUPPLIERS ENGAGED IN EXECUTION OF WORK ON THESE PLANS. 2.3. GENERAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF DRAWINGS AND ADDENDUM'S TO ALL SUBCONTRACTORS ON THE JOB AND COORDINATE THEIR WORK. ANY DISCREPANCIES AND/OR CONFLICTS IN THE DRAWINGS SHALL BE NOTIFIED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY INSTALLATION. FAILURE TO DO SO WILL BE THE ENTIRE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ANY COSTS ARISING TO CORRECT THE DISCREPANCY AND/OR CONFLICT SHALL BE BORNE BY THE RESPONSIBLE PARTY. 2.4. NO DEVIATION OF THE APPROVED SET OF DRAWINGS WILL BE MADE IN THE FIELD WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT AND BUILDING OFFICIAL. IN SUCH CASE THE ARCHITECT SHALL PREPARE REVISION IN ACCORDANCE WITH THE CHANGE. APPROVAL FROM THE BUILDING OFFICIAL SHALL BE OBTAINED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK. 3. ARCHITECT & CONTRACTOR RELATIONSHIP 3.1. UNLESS CONTRACTED DIRECTLY BY CONTRACTOR, THE ARCHITECT AND CONTRACTOR ARE NOT IN A CONTRACTUAL RELATIONSHIP, THE ARCHITECT IS AN AGENT OF THE OWNER. BY SUBMITTING THESE CONSTRUCTION DOCUMENTS FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THATTHEY ARE COMPETENT, UNDERSTAND THE DOCUMENTS, AND ARE BOUND BY THE TERMS OF THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE ACCEPTING LIABILITY THAT MAYARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR'S INCOMPETENCY TO UNDERSTAND THE CONSTRUCTION DOCUMENTS. IT IS NOT THE ARCHITECT'S ERROR OR OMISSION IF THE ARCHITECT DOES NOT SPECIFY/REFERENCE SOMETHING THAT IS REQUIRED BY THE CODES MENTIONED, THE CONTRACTOR AND SUBS ARE REQUIRED TO UNDERSTAND AND ADHERE THE BLDG CODES NO DIFFERENT THAN THE ARCHITECT. 4. WORKMANSHIP: 4.1. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES. 5. COORDINATION: 5.1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK FOR ALL TRADES. 5.2. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THAT THE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FAR AS IT AFFECTS THE TRADES. ALL TRADES SHALL INCLUDE EVERYTHING NECESSARY FOR A COMPLETE AND PROPERLY FUNCTIONING CODE - ACCEPTABLE PROJECT, UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT). 7. CONDITIONS NOT DETAILED: 7.1. CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY CONDITION OR INSTRUCT THE CONTRACTOR ON HOW TO PERFORM THE WORK. EVERY CONNECTION, CORNER, FLASHING, ETC. MUST BE RESOLVED. NOTIFY ARCHITECT IF A CONDITION NEEDS ADDITIONAL DIRECTION OR DETAIL. ARCHITECT IS NOT LIABLE FOR WORK THAT IS NOT DETAILED/SPECIFIED BY ARCHITECT. IF DRAWINGS HAVE A DETAILED SPECIFICATION FOR ACERTAIN PRODUCT, CONTRACTOR MAY REQUEST A SUBSTITUTION APPROVAL BY ARCHITECT. IF DRAWINGS HAVE A GENERIC SPECIFICATION CONTRACTOR IS FREE TO USE ANY PRODUCT THAT MEETS WHAT IS SPECIFIED WITHOUT APPROVAL BY ARCHITECT. 8. VERIFY SITE INFORMATION: 8.1. CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AND ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL CONDITIONS. SHOULD ANY CONDITIONS AFFECTING THE WORK BE DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN. 9. PRIOR TO ANY EXCAVATION WORK: 9.1. THE CONTRACTOR IS REQUIRED TO LOCATE ANY AND ALL UTILITIES IN OR UNDER CONSTRUCTION, AND MAKE ARRANGEMENTS FOR THEIR LEGAL RE-ROUTING, AS ACCEPTABLE TO GOVERNING AGENCIES, AUTHORITIES, UTILITIES AND OWNER. CONTACTALL AFFECTED UTILITY COMPANIES AND INFORM THEM OF THE IMPENDING CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIES. 10. DIMENSIONS: 10.1. DIMENSIONS ON ARCHITECTURAL DRAWINGS MAY BE "ROUGH" OR "FINISH." SEE PLANS FOR REQUIREMENTS. ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENCE OVER STRUCTURAL OR OTHER DIMENSIONS IF NO OTHER CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPANCIES TO ARCHITECT IN WRITING. DO NOT RELY ON SCALED DIMENSIONS. NOTES TAKE PRECEDENCE OVER GRAPHICS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS FOR WORK TO EXISITING BUILDINGS. 11. HEIGHT ELEVATIONS: 11.1. BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAIN FLOOR SLAB AS ELEVATION 0'-0" ( BUILDING ELEVATIONS MAY BE NOTED AS "BLDG EL. _" OR "EL. _" OR "AFF. _") ANY ELEVATION NOT OTHERWISE DESIGNATED AS A SITE ELEVATION IS ON ANY PLANS OTHER THAN THE SITE PLAN IS ASSUMED TO BE A BUILDING ELEVATION. SITE ELEVATIONS MAY BE BASED ON THE SURVEY, WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A REFERENCE DATUM. SITE ELEVATIONS MAY BE NOTED AS: "SEL _" OR "_ NAVD" OR " +X.X' ". CONSULT ARCHITECT FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING. 12. AMBIGUITY: 12.1. IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH REGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT SHALL INTERPRET THE CONSTRUCTION DOCUMENTS. 12.2. IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, CONSULT WITH ARCHITECT. 13. FLORIDA PRODUCT APPROVALS / SUBMITTALS / SHOP DRAWINGS: 13.1. THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTANCE (NOA) / PRODUCT APPROVALS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO MAKE THESE AVAILABLEAT TIME OF INSPECTION. EVEN IF THE ARCHITECT PROVIDES THESE THE CONTRACTOR MAY CHANGE TO A DIFFERENT PRODUCT THAT MEETS THE SAME OR HIGHER BUILDING DESIGN PRESSURES, SOME JURISDICTIONS WILL REQUIRE A REVISION. IF THERE IS A DISCREPANCY BETW THE FASTENING OF PRODUCTS, ACCORDING TO MFR INSTALLATION AND ARCHITECT'S SPECS, VERIFY W/ ARCHITECT. 13.2. SHOP DRAWINGS/SUBMITTALS WILL BE REVIEWED FOR DESIGN CONFORMITY AND GENERAL CONFORMANCE TO CONSTRUCTION DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS ATJOBSITE FOR TOLERANCE, CLEARANCE, QUANTITIES, FABRICATION PROCESSES/TECHNIQUES OF CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES, AND FULL COMPLIANCE WITH CONSTRUCTION DOCUMENTS. 14. GENERAL STRUCTURAL 14.1. ONCE SIGNED & SEALED BY ARCHITECT OR ENGINEER. DESIGN PROFESSIONAL CERTIFIES THAT THE CONSTRUCTION DOCUMENTS MEET THE LOAD REQUIREMENTS STATED IN THE APPLICABLE FBC REFERENCED. 14.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION. PROVIDE APPROPRIATE SUPERVISION THROUGHOUT THE PROJECT. CONSTRUCTION SITE SAFETY, INCLUDING ALL ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. TEMPORARY BRACING AND SHORING SHALL BE DESIGNED TO RESIST ALL CONSTRUCTION LOADS INCLUDING THE WEIGHTS OF ALL SUPPORTED MATERIALS PLUS A LIVE LOAD OF 50 PSF ON HORIZONTAL SURFACES. MAINTAIN TEMPORARY BRACING AND RETAIN IN PLACE UNTIL PERMANENT STRUCTURAL SYSTEMS ARE CAPABLE OF RESISTING ALL CONSTRUCTION PHASE LOADS. 14.3. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS. 14.4. SPECIFIC PRODUCT DATAMUST BE PROVIDED TO ARCHITECT FOR APPROVAL OF HEAVY FINISHES SUCH AS TILE ROOFS OR STONE ON RAISED FLOORS. 15. CAST -IN -PLACE CONCRETE 15.1. ARCHITECT OR ENGINEER OF RECORD TO BE NOTIFIED IN WRITING PRIOR TO POUR, TO GIVE ARCHITECT THE OPTION TO INSPECT THE REINFORCEMENT FOR OVERHEAD BEAMS AND SLABS 15.2. CONCRETE PROPORTIONING, PLACING, FINISHING AND CURING SHALL BE AS PER THE LATEST EDITION OF THE PCA MANUAL. LEAVE SUPPORT FOR ELEVATED CONCRETE IN PLACE UNTIL THE CONCRETE HAS REACHED ITS DESIGN STRENGTH: -OVERHEAD SLABS AND BEAMS TO BE 4000 PSI CONCRETE MIN LINO -COLUMN AND WALL CONCRETE TO BE 3000 PSI CONCRETE MIN LINO -FOOTINGS AND SLAB -ON -GRADE TO BE 3000 PSI CONCRETE MIN UNO -AUGERGAST PILE TO BE 5000 PSI CONCRETE MIN LINO 15.3. CONCRETE, WHEN PLACED, SHALL HAVEA SLUMP OF 6 INCHES MAXIMUM AND 1 INCH MINIMUM EXCEPT FOR SLABS ON -GRADE WHICH SHALL HAVEA MAXIMUM SLUMP OF 5 INCHES AND A MINIMUM OF 3 INCH. 15.4. COMPLY WITH ALL REQUIREMENTS OF ACI 117-10, ACI 318-14, ACI-315 15.5. ALL REINFORCING SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL; WELDED WIRE MESH TO ASTM A-185. ARRANGEMENT AND BENDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE ACI DETAILING MANUAL AND THE CONCRETE REINFORCING STEEL INSTITUTE. DON'T SPLICE IN MIDDLE 1/3 OF BEAM OR COLUMN SPAN, IF A SPLICE IN SPAN IS UNAVOIDABLE, FOLLOW DEVELOPMENT LENGTH/LAP DISTANCE IF NOT NOTED VERIFY W/ ARCHITECT 15.6. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC., PRIOR TO PLACING CONCRETE. 15.7. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. START INITIAL CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER PLACING AND FINISHING. KEEP CONTINUOUSLY MOIST FOR NOT LESS THAN 7 DAYS IN ACCORDANCE WITH ACI 301 PROCEDURES. PERFORM CURING OF THE CONCRETE BY CURING AND SEALING COMPOUND, BY MOIST CURING, BY MOISTURE RETAINING COVER CURING OR BY COMBINATION THEREOF. 15.8. SEE THE DRAWINGS FOR CONCRETE COVER FOR REINFORCING STEEL, BUT IN NO CASE SHALL THE COVER BE LESS THAN THAT REQUIRED BYACI318: -CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH; 3" -CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER, 1 1/2" INCHES; #6 BARS AND LARGER, 2" 15.9. CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND BY KEYED, DOWELED OR SAW -CUT CONTROL JOINTS SUCH THAT THE ENCLOSED AREA DOES NOT EXCEED 260 SQUARE FEET. POST -TENSIONED CONCRETE SLABS ON GRADE SHALL NOT HAVE CONTROL JOINTS UNLESS SPECIFICALLY NOTED ON THE PLANS. EXPANSION JOINT FILLER SHALL BE NON -EXTRUDED PREMOLDED MATERIAL OF ASPHALT IMPREGNATED FIBERBOARD (ASTM D1751) 15.10. CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (BEAMS, COLUMNS, ELEVATED SLABS, ETC.) NOT SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS REQUIRE PRIOR APPROVAL OF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING PROPOSED JOINTS TO ENGINEER FOR APPROVAL. 15.11. ALL CONCRETE SHALL UTILIZE A MINIMUM OF 20% FLYASH CONTENT. 15.12. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERTICAL REINFORCING BARS AT CORNERS, JAMBS OF OPENINGS, BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. VERTICAL WALL REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. -TIES/STIRRUPS TO STARTATA DISTANCE FROM SUPPORT OF 1/2 TIE SPACING 15.13. NO HOLES, CHASES, OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT ARCHITECT'S APPROVAL. 16. CONCRETE MASONRY: 16.1. CMU DESIGNED AND TO BE IN ACCORDANCE ACI 530-13/ASCE 5-13/TMS 402-13, "BUILDING CODE REQ FOR MASONRY STRUCTURES", "COMMENTARY ON BUILDING REQ FOR MASONRY STRUCTURES". 16.2. MASONRY STRENGTH (f'm DESIGN) UNO: -BLOCK STRENGTH = 1900, ASTM C90 -MORTAR STRENGTH = 1800, TYPE S -GROUT STRENGTH = 2000 16.3. GROUT SHALL HAVE A SLUMP OF 8 TO 11 INCHES BE IN CONFORMANCE WITH ASTM C 476-02 AND ATTAIN A COMPRESSIVE STRENGTH OF 3000 PSI. GROUT SHALL CONFORM TO REQUIREMENTS OF FLBC STANDARDS. USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT SEGREGATION. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL BE FILLED SOLID WITH GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. HOLD GROUT DOWN 1-1/2" BELOW TOP OF BLOCK AT GROUT LIFT JOINTS AND AT CONCRETE PLACED OVER MASONRY. 16.4. CONCRETE MASONRY UNITS SHALL BE PLUMB, TRUE TO LINE, WITH LEVEL COURSES ACCURATELY SPACED AND BUILT TO THE THICKNESS AND IN A RUNNING BOND AS INDICATED AND CONFORMING TO THE TOLERANCES SPECIFIED IN ACI 531.1 AND 530.1. 16.5. REINFORCING BARS SHALL BE PLACED IN THE MIDDLE OF THE CELLS UNLESS NOTED OTHERWISE AND TIED OR OTHERWISE SECURELY SUPPORTED ATTHE TOP AND BOTTOM TO ENSURE THATTHE BAR DOES NOT MOVE DURING GROUTING. 16.6. MORTAR DROPPINGS AND OTHER DEBRIS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED. 16.7. CONTROL JOINTS SHALL BE PROVIDED IN ACCORDANCE WITH THE LOCATIONS AND DETAILS SHOWN ON THE DRAWINGS. CONTROL JOINTS SHALL NOT EXTEND THROUGH THE TOP BOND BEAM COURSE. THE JOINTS ON BOTH SIDES OF THE WALL SHALL BE SEALED AND TOOLED SMOOTH. 16.8. WALL REINFORCEMENT: VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SPECIFIED ON THE DRAWINGS. DESPITE IF SHOWN ON DRAWINGS- PLACE VERTICAL REINFORCING BARS AT CORNERS, EA CELL WITHIN 16" OF CORNER, JAMBS OF OPENINGS, EA CELL WITHIN 16" OF JAMBS FOR OPENINGS WIDER THAN 12', BELOW BEAM BEARING, BELOW GIRDER TRUSS BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. IF NOT SPECIFIED IN TEXT ON DRAWINGS USE #5 @ 48" OC. WALL REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. 8" TOLERANCE ALLOWED FOR WALL REINF SPACING. SEE DOWEL NOTE 17.2 BELOW. 16.9. REINFORCED MASONRY LINTELS SUCH AS CAST CRETE TO BE INSTALLED AS PER MFR INSTRUCTIONS. LINTELS TO HAVE 4" MINIMUM BEARING. CONTINUOUS REINF ACROSS COLUMNS. IF SPECIFIED, CA LINTEL LENGTH IS +/- AS LONG AS MIN BRG IS MET. DOOR/WINDOW LINTELS CAN BE DEEPER(TALLER) THAN SPECIFIED BUT NOT SHORTER. 16.10. UNO HORIZ JOINT REINFORCEMENT @ 16" OC IN MASONRY WALLS IS SUGGESTED BUT NOT REQUIRED TO CONTROL CRACKING. 16.11. BOND/TIE BEAMS/LINTELS- CONTINUE REINFORCING BARS CONT (UNINTERRUPTED) AROUND ALL CORNERS, OVER OPENINGS, ACROSS WALL INTERSECTIONS, THROUGH TIE COLUMNS, AND UP/DOWN AT CHANGES IN BOND BEAM ELEVATION. 16.12. ALTERNATE WINDOW SILL: 4"H MIN x 8"W CAST CONC W/ (1) # 5 EXTENDED 4" INTO FILLED JAMB CELLS. 17. FOUNDATIONS: 17.1. BUILDING AREA TO BE STRIPPED/GRUBBED OF SURFACE DEBRIS/VEGITATION. FILL TO BE CLEAN GRANULAR & UNIFORMLY COMPACTED TO 95%" DENSITY (ASTM D 1557) AND MEASURED IN 12" LIFTS. AT DISCRETION OF CONTRACTOR OR BLDG INSPECTOR, ARCHITECT RECOMENDS SOIL TO BE TESTED BY GEOTECH ENGINEER TO ENSURE MINIMUM SOIL BEARING PRESSURE CAPACITY & RECOMEND SITE PREP. 17.2. DOWEL VERTICAL REINFORCING BARS OUT OF THE FOUNDATION OR STRUCTURE BELOW WITH BARS OF THE SAME SIZE AND SPACING OF WALLABOVE. THERE SHALL BE A DOWEL FOR EACH VERTICAL REINFORCING BAR. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. For#5: MINIMUM 30" LAP W/ 10" HOOK UNO. SEE WALL REINFORCEMENT NOTE 16.8ABOVE. FOR MISSED EMBEDDED DOWEL, EPDXY EMBED W/ 1/8" OVERSIZED HOLE DIA., 6" EMBED W/ CLEAN HOLE. 17.3. BUILDING SLABS -ON -GRADE TO BE REINFORCED WITH 6x6 10/10 WWF MIN WITH MESH UP CHAIRS OVER 6- MIL MINIMUM POLYETHYLENE FILM VAPOR RETARDER OVER TERMITE TREATED COMPACTED GRADE UNO. SUGGESTION TO PROVIDE DIAGONAL 36" #4 REBAR ATALL INSIDE 'REENTRANT' CORNERS. 17.4. CONTINUOUS FOOTINGS, STEM OR MONOLITHIC, TO BE REINFORCED CONTINUOUS, WITH LAPS AS PER STATED DEVELOPMENT LENGTH IF NOTED OR 48x BAR DIAMETER MIN UNO. 30" MIN CORNERS BARS TO MATCH LONGITUDINAL REBAR. 17.5. SUGGESTION TO PROVIDE A 4-INCH MEDIUM TO COARSE SAND OR GRAVEL COMPACTED DRAINAGE FILL BELOW ALL INTERIOR SLABS -ON -GRADE. 17.6. SOIL AND SUBGRADE IS TO BE TERMITE TREATED. 17.7. SLAB FINISHES UNO: -MAIN BUILDING: STEEL TROWEL FINISH -GARAGE: STEEL TROWEL, THRESHOLD: LIGHT BROOM -DRIVEWAY, DRIVEWAYAPRON, PORCHES/PATIOS: LIGHT BROOM 17.8. GARAGE, AND ALL EXTERIOR HARD SURFACES TO SLOPE AWAYFROM BLDG MIN 1/8"/FT. 17.9. CONCRETE PADS FOR VIBRATING EQUIPMENT SUCH AS PUMPS OR MOTORS TO BE SEPARATED FROM HOUSE SLAB WITH A MINIMUM OF AN ASPHALT EXPANSION JOINT. 17.10. RECESS SGD & GARAGE DOOR THRESHOLDS 3/4% VERIFY EXACT DIMENSIONS WITH SUPPLIER/MFR. 17.11. COLUMN/WALLAND FOOTING CENTERLINES SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 17.12. SLOPE GRADES AWAY FROM BUILDING ON ALL SIDES A MINIMUM OF 6" OVER 10' 4:1 SLOPE MAX. 18. STRUCTURAL STEEL: 18.1. ALL STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A-36 AND THE "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. ALL STEEL PIPE SHALL CONFORM TO ASTM A-53 TYPE E (FY = 35 KSI). 18.2. ALL SHOP CONNECTIONS TO BE WELDED AND FIELD CONNECTIONS TO BE BOLTED UNLESS OTHERWISE SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS. ALL WELDING IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE". USE E70XX ELECTRODES LINO. 18.3. ALL STEEL TO RECEIVE ONE SHOP COATAND ONE FIELD TOUCHUP COAT OF APPROVED PAINT. 18.4. ALL BOLTED CONNECTIONS SHALL CONSIST OF ASTM A325 HIGH STRENGTH BOLTS AND HARDENED WASHERS AS SHOWN ON THE STRUCTURAL DRAWINGS. ALL BOLTED CONNECTIONS SHALL CONFORM TO THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. 18.5. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A36 OR A307 (THREADED ROD). 18.6. SUBMIT SHOP DRAWINGS FOR REVIEW OF CONFORMANCE TO DESIGN CONCEPT. 18.7. GROUT FOR COLUMN BASE PLATES SHALL BE NON -SHRINK GROUT 5000 PSI MINIMUM. 19. LIGHT GAGE METAL STUDS & MISC. METAL FRAMING: 19.1. ALL LIGHT GAGE METAL INTERIOR STUDS SHALL BE G90 GALVANIZED 25 GA MINIMUM. USE 20 GA STUDS WHERE HEAVY LOADS ARE HUNG FROM SUCH AS TV's OR WALL CABINETS. ALL WALL TRACKS SHALL BE 25 GA. 20. HVAC: 20.1. PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF UNITS, DUCTS, RETURN AIR GRILLES AND SUPPLY GRILLES ETC, SHALL BE DETERMINED BY HVAC LICENSED CONTRACTOR. IF LAYOUT/SIZING IS PROVIDED HVAC CONTRACTOR TO VERIFY. 20.2. PROVIDE MANUFACTURED CONCRETE PADAND BRACKETS RATED FOR SPECIFIED WIND LOAD FOR CONDENSING UNIT. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE MANUFACTURER'S SPECIFICATIONS. 21. WOOD FRAMING 21.1. ALL STRUCTURAL (LOAD BEARING) LUMBER SHALL BE S.Y.P. OR DOUGLASS FIR, GRADE #2, KID 19% (Fb FOR LUMBER SIZES NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND THE SOUTHERN FOREST PRODUCTS ASSOCIATION. ALL NON -LOAD BEARING FRAMING LUMBER (INTERIOR WALLS) TO BE #2 S.P.F. OR BETTER. 21.2. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL WOOD EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO 0.80 CCA. 21.3. SPLICING FOR MULTI -PLY HEADERS/BEAMS/COLUMNS: -2x4- 10d COMMON NAIL @ 6" OC EACH LAYER STAGGERED. -2x6- 2 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x8- 3 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x10- 4 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x12- 5 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -LOCATE SPLICES OVER BRG SUPPORTS. GLUE BETW LAYERS. USE 16D IF 1/2" PLY SPACER USED 21.4. LAMIN��/+, LTA FABRIGATORTO SUBMIT SHOR DRAWINGS AND GALGULATIONS FOR ALL ELEMENTS OVER SIGNATYREAND SEAL OF FLORIDA ENGINEER (SPEGIAI TV ENGINEER) AND INTERVALS FOR DEGK. (GONNEGTIONS FOR BEAM ENDS TO RESIST ROTAxIoN.) 21.5. GLUE LAMINATED BEAMS (GLULAM) SHALL BE DOUGLAS FIR GOMBINATION 24F V4 AT SIMPLE SPANS AND 24F V8 AT GANTILEVER SPANS HAVING THE FOLLOWING MINIMUM PROPERTIES� Fb - 2,409 PSI, Fv - 19042&k, Fe (PERPENDIGULAR) - 650 PSI, E - 1,800,000 PSI, FABRIGATIGNAND HANDLING SHALL GONFORM TO THE LATEST AMERIGAN INSTITUTE FOR TIMBER GONSTRYGTION (AITG) AND ASTM STANDARDS. BEAMS SH BEAR AN APPROPRIATE GRADE STAMP GLEARLY NOTING ITS DESIGN PROPERTIES. UNLESS GAMBER AND TOLERANGE IS SPEGIFIGALLY NOTED ON THE DRAWINGS, BEAMS SHALL BE MANUFAGTURED WITH INDUSTRY STANDARD MINIMYM GAMBER OR YPWARD TO SPAN1200. EREGT WITH GROWN OR GAMBER YP. IN HEADER GONDITIONS (BEAM BUILT INTO WALL) GRIPPLE FRAMING ABOVE HEADER SHALL MAINTAIN GAMBER. HEADER BEAMS MAY HAVE ZERO SPEGIALTY ENGINEER MAY SUBMIT GONNEGTION DETAILS FOR BENTS AND BEAMS AND FASTENING MODE PROVIDED GRIPPLE FRAMING ABOVE HEADER IS BUIL WITL. MINIMUM GAMBER STATED ABC)VE21.6. LAMINATED LUMBER AND "I" jQISTS AND RAFTERS SHALL BE INSTALLEDAS PER MANYFAGTlJRE 21.7. END STUDS OF EXTERIOR FRAME WALL OR DESIGNATED INTERIOR SHEAR WALLS TO ATTACH TO CONC WALL W/ .25" x 3.25" TAPCON @ 16" OC/8" ENDS. FOR INTERIOR BRG WALLS USE 1/4" x 2.75" TAPCON @ 32" OC/8" ENDS. 21.8. ALL WOOD NAILING AS PER FBC R 602.3 UNO. 22. PLYWOOD SHEATHING: 22.1. ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS. 22.2. UPPER PANELS TO BE ATTACHED TO THE TOP MEMBER OF THE UPPER DOUBLE TOP PLATE AND TO RIM JOIST AT BOTTOM OF WALL. PROVIDE BLOCKING FOR ALL EDGE NAILING OVER LENGTH OF PLYWOOD 22.3. FOR EXTERIOR AND INTERIOR SHEAR WALLS USE 1/2" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF CORNERS. NAIL SPECS: ASTM F1667 RSRS-03 (21/2" x 0.131") 22.4. FOR ROOF USE 5/8" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF EAVES/RIDGES/GABLES. 22.5. FOR SUBFLOOR USE 3/4" PLYWOOD AND 2.5" #8 SCREWS & GLUE OR 8d RINGSHANK GALV NAILS & GLUE. SPACE FASTENERS 6" FIELD, 6" EDGE. 22.6. FOR ATTIC FLOOR USE 5/8" PLYWOOD AND 6d RINGSHANK GALV NAILS. SPACE NAILS 12" FIELD, 12" EDGE. ONLYALLOWED WHERE TRUSS ENGINEERING SPECIFIES. 23. PE TRUSSES: ABBREVIATIONS: 23.1. FIELD VERIFY WITH ARCHITECT EXACT LOCATION AND CONFIGURATION BEFORE MODIFYING EXISTING TRUSSES. DO NOT CUT ANY FRAMING MEMBERS OR TRUSSES WITHOUT EXPRESS WRITTEN AUTHORITY AB ANCHOR BOLT FROM THE ENGINEER AND ARCHITECT. A/C AIR CONDITIONER 23.2. FIELD VERIFY DIMENSIONS OF NEW PRE-ENGINEERED TRUSSES PRIOR TO CONSTRUCTING. AHU AIR HANDLING UNIT 23.3. CONTRACTOR TO SUBMIT THE TRUSS ENGINEERING TO ARCHITECT TO REVIEW FOR ADHERENCE WITH AT ACOUSTICAL TILE DRAWINGS PRIOR TO CONSTRUCTION. ARCHITECT'S SEAL WILL NOT BE APPLIED. 23.4. TRUSS CONFIGURATION DRAWN ARE SCHEMATIC ONLY HOWEVER THE SUPPORTING STRUCTURE HAS B.M. BENCH MARK BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL BM BEAM FINAL LAYOUT MY MFR. EXACT TRUSS WEB, CHORD SIZES AND LAYOUT ARE TO BE DETERMINED BY THE BC BOTTOM CHORD MFR. TRUSS MFR TO DESIGN ANY PERMANENT BRACING REQUIRED FOR STABILITY. BILK BLOCK 23.5. ALL TRUSSES FURNISHED SHALL BE SUPPLIED WITH SIGNED AND SEALED TRUSS DIAGRAMS PROVIDING BO BY OWNER THE MFR'S TRUSS SPECIFIC REQUIREMENTS FOR BRACING AND LATERAL MOVEMENT. ALL TRUSS -TO- BOTT BOTTOM TRUSS CONNECTORS TO BE SUPPLIED BY THE TRUSS MFR. VERIFY THAT THE CAPACITY OF THE TRUSS BP BOTTOM PLATE ANCHORS CALLED OUT ON THE CONSTRUCTION DRAWINGS MEET OR EXCEED THE UPLIFT VALUES ON THE TRUSS ENGINEERING. ANY TRUSS ANCHORS CALLED OUT THATARE OF INSUFFICIENT CAPACITY CJ CONTROL (CONSTRUCTION) JOINT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR SUBSTITUTION. CL CENTER LINE 23.6. BRACE BOTTOM CHORD AS PER MFR SPECS, IF NOT PROVIDED, PROVIDE CONTINUOUS 'RAT RUN' CLG CEILING LATERAL BRACE PERPENDICULAR TO BC 2x4 @ 12' OC (2) 12d NAILS EA BC. CLR CLEAR 23.7. PREFABRICATED WOOD TRUSSES, JOISTS, AND GIRDER TRUSSES SHALL BE DESIGNED TO SUPPORT CMU CONCRETE MASONRY UNIT THEIR SELF -WEIGHT, PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. INCLUDING, BUT NOT LIMITED CO CONNECTOR TO, WALLS EITHER PARALLEL OR PERPENDICULAR TO THE SPAN, ALL MECHANICAL AND OTHER COL COLUMN EQUIPMENT, AND SHALL DESIGNED TO RESIST ALL DRAG FORCES, SHEARWALL UPLIFT AND DOWNWARD CONC CONCRETE LOADS, AND OTHER SPECIAL LOADS NOTED ON STRUCTURAL, MECHANICAL, PLUMBING, OR CONT CONTINUOUS ARCHITECTURAL DRAWINGS OR CALCULATIONS. MINIMUM ALLOWABLE SHEAR SHALL BE 95 PSI, CU CONDENSING UNIT OR COPPER BRIDGING SIZE AND SPACING SHALL BE AS DESIGNATED BY TRUSS MFR UNLESS NOTES OTHERWISE. CW COLD WATER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS CXN CONNECTION SEALED BYA REGISTERED ENGINEER. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICBO APPROVAL. THE MFR SHALL DESIGN D NAIL SIZE (PENNY) CONNECTION OF TRUSS REQUIRING PREFABRICATED HARDWARE HANGER OR OTHER. DF DRINKING FOUNTAIN 23.8. FABRICATORTO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE DIA DIAMETER AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER). SPECIALTY ENGINEER MAY SUBMIT DIM DIMENSION PREFERRED CONNECTION AND OTHER DETAILS IF DIFFERENT FROM SAME ON DRAWINGS FOR DISP DISPOSAL APPROVAL. DIN DOWN DR DRYER 24. CONNECTORS/FASTENERS: DTL DETAIL 24.1. CONNECTORS BY SIMPSON OR APPROVED SIMILAR TO BE HDG OR ZMAX COATED IF UNEXPOSED TO DW DRIVEWAY WEATHERAND TO BE STAINLESS STEEL IF EXPOSED TO WEATHER UPON COMPLETION. 24.2. UPLIFT CONNECTORS MAYBE SUBSTITUTED WITH CONNECTORS WITH >_ THE DOCUMENTED UPLIFT 'E' EXISTING VALUE IS >_ SPECIFIED CONNECTOR. UNLESS SPECIFIED UPLIFT CONNECTORS ARE NOT REQUIRED ON EA EACH LOADBEARING WALLS THAT ARE NOT SUBJECT TO UPLIFT OR SHEAR. SPACE NAILS AT STRAPS AS TO EJ EXPANSION JOINT NOT SPLIT WOOD, USE MINIMUM NAIL QTY REQUIRED BY MFR. IF MULTIPLE FASTENER OPTIONS USE EL BUILDING ELEVATION EITHER UNLESS SPECIFIED BYARCHITECT. ELECT ELECTRICAL ELEV ELEVATOR OR ELEVATION 26. EXTERIOR DOORS AND WINDOWS: EW EACH WAY 26.1. INSTALL OVERHEAD DOORS (INCLUDING BUCKS), EXTERIOR DOORS, AND WINDOWS AS PER MFR'S EWC ELECTRIC WATER COOLER SPECIFICATION/ PRODUCT APPROVAL. EWH ELECTRIC WATER HEATER 26.2. PT 1x BUCK: ATTACH TO MASONRY/GONG W/ADHESIVE &RECESSED 3/16"x2" MIN TAPCON OR 6D CASE EXP EXPOSED HARD NAILS OR T NAILS @ 12"/3" END. ATTACH TO MASONRY/CONC W/ADHESIVE & RECESSED 3/16"x2" EXT EXTERIOR MIN TAPCON OR 6D CASE HARD NAILS OR T NAILS @ 12"A" END. PT 2x BUCK: ATTACH TO MASONRY/CONC EXTG EXISTING W/ADHESIVE & RECESSED 1/4"x3 1/4" MIN TAPCON @ 8"/4" END. 26.3. MIN OVERHEAD DOOR BUCK: 2x6 @ SIDES TO FILLED CELL W/ WEDGE ANCHOR @ 24" OC MIN, 12" FROM F1 FOOTING #1 ENDS. WEDGE ANCHOR TO BE 1/2" x 6" W/ 2" x 1/8" WASHER. 2x6 @ TOP TO LINTEL W/ 1/4" x 2.75" FA FASTENER TAPCONS STAG @ 24" OC. FD FIELD (FLOOR) DRAIN 26.4. CONTRACTOR TO VERIFY THE FOLLOWING WITH MFR/SUPPLIER PRIOR TO CONSTRUCTION: FE FIRE EXTINGUISHER -ROUGH OPENING DIMS, EGRESS COMPLIANCE (FBC R310), SAFETY GLASS COMPLIANCE (FBC R308.4) FF FINISH FLOOR 26.5. CONTRACTOR TO FIELD VERIFY OPENINGS BEFORE ORDERING DOORS/WINDOWS. FIN FINISH 26.6. DOORS BETWEEN GARAGE & RESIDENCE TO BE 20 MINUTE FIRE RATED OR 1-3/8" THICK SOLID WOOD AS FLR FLOOR PER FBC R 302.5.1. FP FIRE PROTECTION 26.7. FLASHING AS PER FBC R703.4 AND REFERENCED FMA/AAMA DOCUMENTS. EPS EXPANDED POLYSTYRENE 26.8. GLASS TO HAVE: LOW-E, U-FACTOR <- 0.4, SHGC <- 0.25 FTG FOOTING 26.9. SIZES ARE NOMINAL AND CAN VERY +/- 2" IN SIZE IF EGRESS IS NOT EFFECTED. FT FOOT (OR FEET) 27. ELECTRICAL & LIGHTING NOTES GALV GALVANIZED 27.1. PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF CIRCUITS, RECEPTACLES, FIXTURES, AND GFI GROUND FAULT INDICATOR EQUIPMENT, SHALL BE DETERMINED BY AN ELECTRICAL CONTRACTOR. IF LAYOUT/SIZING IS PROVIDED GSF GROSS SQUARE FEET ELECTRICAL CONTRACTOR TO VERIFY. GWH GAS WATER HEATER 27.2. ALL 120V 15AAND 20A DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT TYPE. GWB GYPSUM WALL BOARD 27.3. PROVIDE AFIC AS DETERMINED BY NEC 210.12 OR FBC R 3902. 27.4. PROVIDE GFIC AS DETERMINED BY NEC 210.8 OR FBC R 3902. HB HOSE BIB 27.5. ALL EXTERIOR OUTLETS TO BE GFIC WITH WEATHER TIGHT PROTECTIVE COVER. HC HOLLOW CORE 27.6. SMOKE ALARMS SHALL BE HARD WIRED, INTERCONNECTED, W/ BATTERY BACKUP PER FBC R314. HHDG DG HOT DIPPED GALVANIZED 27.7. CARBON MONOXIDE ALARM TO BE INTEGRAL WITH SMOKE ALARM AND COMPLY WITH FBC R315. HORIZONTAL 27.8. PROVIDE POWER RECEPTACLE & LIGHT, WHEN ATTIC CONTAINS AHU OR HAS STORAGE AREA. HW HOT WATER HWH HOT WATER HEATER 28. PLUMBING: 28.1. PLANS ARE SCHEMATIC. ACTUAL LOCATION MATERIAL AND SIZE OF PIPES DRAINS AND VENTS SHALL IN INCH BE DETERMINED BY LICENSED PLUMBER. IF LAYOUT/SIZING IS PROVIDED PLUMBING CONTRACTOR TO INT INTERIOR VERIFY. 28.2. SEPTIC & DRAIN FIELD IS SCHEMATIC, EXACT LAYOUT/SIZING SHALL BE BY A LICENSED SEPTIC JT JOINT CONTRACTOR AND ADHERE TO 64E-6, F.A.C. 28.3. NO PLUMBING REQUIREMENTS SHALL INTERRUPT THE STRUCTURAL INTEGRITY OF THE BUILDING. MAX MAXIMUM MEP MECH/ELECT/PLUMB 29. ROOF PENETRATIONS: MFR MANUFACTURER 29.1. VERIFY ALL REQUIRED ROOF PENETRATIONS FROM HVAC, PLUMBING, ELECTRICAL, AND OTHER MIN MINIMUM DRAWINGS. PROVIDE ALL NECESSARY PENETRATIONS WITH REQUIRED ACCESSORIES TO PREVENT MO MASONRY OPENING MOISTURE INTRUSION AND RETAIN STRUCTURAL STABILITY, IN ADDITION TO THOSE INDICATED ON THE MW MICROWAVE ROOF PLAN. CONSULT ARCHITECT IF ROOF PLAN CONFLICTS WITH ANY REQUIRED ROOF PENETRATIONS. NIC NOT IN CONTRACT 31. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: NTS NOT TO SCALE 31.1. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: NSF NET SQUARE FEET 31.2. FINISHES TO COMPLY WITH THE BELOW FIGURES AS PER FBC R302.9 - 302.10 31.3. INSULATION FLAME SPREAD: <25, INSULATION SMOKE DEVELOPED: <450 L-1 LINTEL #1 31.4. WALL/CLG FLAME SPREAD: <200, WALL/CLG SMOKE DEVELOPED: <450 LF LINEAL FOOT 32. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA: OA OVERALL 32.1. WEATHERING: NEGLIGIBLE, TERMITE AREA: VERY HEAVY OC ON CENTER OAS OR APPROVED SIMILAR 33. MISC: 33.1. ROOF SYSTEM & FLASHING AS PER MFR INSTRUCTIONS. PL PROPERTY LINE OR PLATE 33.2. GUARDRAILS AS PER FBC R312. PLY PLYWOOD 33.3. STAIRWAYAS PER FBC R311.7. PT PRESSURE TREATED 33.4. MEP SYSTEMS V+ BFE, AS PER FBC R322.1.6. PVC POLYVINYL CHLORIDE 33.5. MECHANICAL APPLIANCES TO BE PROTECTED IF INSTALLED ON FLOOR IN GARAGE AS PER M1307.3.1. USE 2" DIA x 36"H PIPE W/ COLLAR BASE, ATTACH COLLAR TO SLAB W/ (4) 1/4" x 2.25" TAPCON. R RADIUS 33.6. CAULK BOTTOM OF SOLE PLATE AT GARAGE COMMON FRAME WALL. R/A RETURN AIR 33.7. IGNITION BARRIER NOT REQUIRED FOR SPRAY FOAM IN ATTIC UNO. RCB REINFORCED CONCRETE BEAM 33.8. PROVIDE FIRE BLOCKING AS PER FBC R 302.11. RCC REINFORCED CONCRETE COLUMN 33.9. PROVIDE DRAFT STOPPING IN THE FORM OF I%" PLY OR GWB TO FLOOR GEILING ASSEMBLIES GREATER RD ROOF DRAIN THAN 1,000SF AS PER FBG R302 12 REF REFRIGERATOR REINF REINFORCING 34. FINISHES: REQ REQUIRED 34.1. GWB: MOISTURE RESISTANT GWB @ ALL WET AREAS, CEMENT BOARD INSIDE SHOWER COMPARTMENTS. R/W RIGHT-OF-WAY USE 5/8" TYPE X GWB ON GARAGE CEILING IF CONDITIONED/HABITABLE AREAABOVE. GARAGE RTU ROOF TOP UNIT SEPARATION WALL TO HAVEA MINIMUM OF ONE 1/2" LAYER OF GWB ON THE GARAGE SIDE OF WALLAS PER FBC R302.6. SEE DOOR GEN NOTE 26.6. S. SIMPSON (MFR) 34.2. EXTERIOR LATHAS PER FBC R703.7.1/ASTM C1063-11A. FOR EXTERIOR CEILINGS/SOFFITS USE MIN. 5/8" SIBS STYRENE BUTADIENE STYRENE STUCCO ON RIBBED LATH. ATTACH TO BOTTOM OF WOOD FRAMING W/ 11GA NAILS W/ 3/8" HEAD @ 6" OC SEL SITE ELEVATION W/ 1-3/4" EMBED INTO WOOD. TYP TRANSITION FROM WOOD TO CONC (I.E. @ GABLE END) TO HAVE A SF SQUARE FOOT VINYL CONTROL JOINT IN STUCCO. SIM SIMILAR 34.3. EXTERIOR T&G WOOD CEILING. ATTACH 1x4 OR 1x6 BOARD W/ 2" 16GA FINISH NAIL EA RAFTER/JOIST/BC. SK SINK TO CHANGE ORIENTATION USE 2x4 FLAT PURLINS ATTACHED TO EA RAFTER/JOIST/BC W/ (2)16D NAIL. SOG SLAB ON GRADE SS STAINLESS STEEL STAG STAGGERED TBD TO BE DETERMINED TC TOP CHORD THE TO MATCH EXISTING TOB TOP OF BEAM TOB TOP OF COLUMN TOS TOP OF SLAB TP TOP PLATE TPO THERMO PLASTIC OLEFIN TYP TYPICAL UG UNDER GROUND LINO UNLESS NOTED OTHERWISE VB VAPOR BARRIER VERT VERTICAL VTR VENT THRU ROOF W/ WITH WA WASHER MACHINE WP WATER PROOF WD WOOD WWF WELDED WIRE FABRIC/MESH # POUND OR NUMBER co I'- ti E 0 :t d 0 L W - 0 � - _ E .; - U 0. 0i a C = 00 c - • O N O (6 a)to 0- to 'a V =� dco U) E� = Q = + C- Zo� _ C(.0�V :3Co r m Q M W m O >�v -N a.- O M I-- 0) fn O /1� W ,6- 2 = N + N ~ Y D o c O co co c J co LL ILLV U `-- U U w 0 IY a. U U_ U w a. U) U) T of 0 0 w a. 0 /'� V J w > w 0 0 z a 0 w J 0 Ww CM > w U Q w Z LU U WW a) w [if V U L z ZV �0_%� / ^ U W 0- w a 0 W 0�Q -L_ z 0 J � J O � m z (DCn -W w 0 J W < 0f w 0 L,L -�>_ 0 Q� O W r a 0 0� a n v U w x T w Q Zi - Er a w W' tJo ) w_ �_ ( Al W F W 2 z z 0 0 Z rn V ! w < U Ir- 0 z O z z w 2 'r-- w z Of < 0 z < U) z J a ui z 0 U) w 0 a w 0 J < 0 Z W 2 2 O U W Q 0 0 general notes 3/28/20 SHEET GN-1 DocuSigned by: vaan Ut,l�l.w E935FAF3OE92486_ 3/28/2021 F rr� O FAOR !O S P. L/Fe9 `:,\A � .:-*- :. AR97108 , DocuSign Envelope ID: 92EDA28E-CB24-4D08-A531-C8E6A6818852 VERIFY ALL DIM ' s., WALL & COL. HGT ' s. , GIRDER , CLG. COFFER CLG. & COL. LOCATIONS, END DETAIL , PITCH, FASCIA , O. H & CANT. DIM. ' s SOME DOWN FRAMING REQ. BY BLDR. @a DROP CLG. , CLG. CHANGE & COFFER CLG. AREAS N 5-1Z2" 37' 12'8" 24'4" 93' 20'4" 17'4" 12' 12' 14' 10" 7' —{ 14' 10" I I 12'8" 5'6" I 10'8" 5'6" 7'4" 36'8" 14'8" I 93 36'8" A37 12 5 5-1T2" 1L N 35' - T A11 '2-7/8" 5-1/2" 0 12 5 BEAM SCHEDULE 10,0" TYPICAL_ CERNER SET APPROVED TRUSS ANCHOR BY BUILDER 2x4 MINIMUM TOP AND BOTTOM CHORDS PLUMB CUT CANTLIVER 12 5 �-21011 ---2x4 --- _ HEEL 1-9 1.5 UNLESS NOTED OTHERWISE BRG a 0 12 TYPICAL,- TRUSS END N I I 1-6-1 21'8" A4 1'2-7/8" i OO Q J 0 O CL Q W O U Q W LU 1--Z Q 0 Z LU OO 4 W �D U U Q m W m O J ti O Q OO Q J O O I Q J ti m m J J W W O Q J 0 CL i O LU Q W CK- INDICATES LEFT END OF TRUSS WHEN REVIEWING ENGINEERING SHEETS THIS WILL BE THE LEFT SIDE OF THE PAGE DESIGN CRITERIA FBC 7th Ed. 2020 Res. ASCE 7-16 MWFRS EXP, WIND SPEED CATEGORY C 170 Residential - CAT II DESIGN LOAD R❑❑F(PSF) FL❑❑RCPSF> T.0 LL 20 T.0 LL T.0 DL 10 T.0 DL B.0 LL 0 B.0 LL B.0 DL 10 B.0 DL TOTAL LOAD 40 TOTAL LOAD 10 PSF N❑N—C❑NC, LOAD AT B.0 HANGER ID CONN. ROOF FLOOR UPLIFT GIRDER TRUSS A THD26 2X6 3060 2645 2265 18-16d 12-10dx11/2 B THD28 2X8 4485 4115 2330 28-16d 16-10xd11/2 C THD26-2 2X6 3355 2770 2340 18-16d 12-10d D THDH-26-2 2x6 5245 4375 2340 20-16d 8-16d E THDH26-3 2X6 5245 4375 2340 20-16d 8-16d F THD28-2 2X8 5005 4310 2595 28-16d 16-10d G THDH28-2 2x8 8025 7360 3330 36-16d 10-16d H THDH28-3 2X8 7835 7595 4370 36-16d 12-16d I THD46 2X6 3175 2540 2285 18-16d 12-10d J HJC26 2X6 3490 ----- 2135 16-16d 5-10d K SKHH46L/R 2x6 2100 1680 1345 12-16d 6-16d L SKHH26L/R 2x6 1890 1510 2190 18-16d 12-10dx11/2 M SKHH26L-2/R-2 2x6 2100 1680 895 12-16d 4-16dx2 1/2" N 0 0 GTWS2T 2X8 10900 8720 8345 22-WS3 16-WS3 P GTWS3T 2X8 1247011100 12490 28-WS3 24-WS3 Q GTWS4T 2X8 1247011100 12490 28-WS3 24-WS3 R OR EQUAL BY BYOBLDR. ----- 1545 Talcon 9-10d S x Y Z CONN. BY BLD TRUSS TO TRUSS CONNECTIONS THAT EXCEED THE CAPACITY OF A STANDARD HANGER ARE THE RESPONSIBILITY OF THE BUILDER HANDLING AND ERECTION CARELESS HANDLING OF TRUSS(ES) SHALL NOT BE PERMITTED. TEMPORARY AND PERMANENT BRACING FOR HOLDING TRUSS(ES) PLUMB AND FOR RESISTING LATERAL FORCES SHALL BE DESIGNED AND INSTALLED BY OTHERS. NO LOADS OTHER THAN THE ERECTORS, ARE TO BE APPLIED TO TRUSS(ES) UNTIL AFTER ALL BRACING AND FASTENINGS ARE COMPLETED.AT NO TIME SHALL CONCENTRATED LOADS GREATER THAN DESIGN LOADS BE APPLIED TO TRUSS(ES). SIGNATURE BELOW, VERIFIES THAT THE EOR, OR RESPONSIBLE PARTY, HAS BEEN GIVEN A COPY OF THIS TRUSS REPLACEMENT PLAN WITH TRUSS ENGINEERING, FOR REVIEW AND COMMENT, FURTHER, THAT THESE DOCUMENT ARE IN CONFORMANCE WITH BEARING CONDITIONS, ROOF PITCH, HEEL HEIGHT, OVERHANG, AND SPECIAL LOADING CONDITIONS, TO INCLUDE BUT NOT LIMITED TO, AIR HANDLERS, LIGHT FIXTURES, AND ATTIC ACCESS STAIRS, WHICH HAVE BEEN SPECIFIED BY RESPONSIBLE PARTY.ALSO THAT FOR OR RESPANSIBLE PARTY HAVE REVIEWED AND ARE IN AGREEMENT WITH , TRUSS PLACEMENT PLAN AND TRUSS ENGINEERING NOW PRESENTED, AND READY FOR FABRICATION. ALL DIMENTIONS & CONDITIONS THAT EFFECT WOOD TRUSSES MUST BE VERIFIED BY BLDR. AND/OR ARCHITECT AND FOR BEFORE ANY PRODUCTION OF WOOD TRUSSES. EF DocuSigned by: rat, IC � LD� r E935FAF30E92486... APPROVED BY 3/28/2021 DATE FOR APPROVAL PURPOSES ONLY. DO NOT USE TO SET TRUSSES UNLESS STAMPED «FINAL» HERE REVISI❑NS 12.29.2020 1 1.4.2021 1 2.19.2021 Carl G.Forbes P . E . # 2 0 6 9 9 1000 S. Dixie HWY W. Pompano Beach A 33060 DATE (561)686 4000 SPEC I RUSS FAX:(561)687 3814 dba US TRUSS WEBIWWW.USTRUSS,COM 3400 WEST 45th, STREET, WEST PALM BEACH,FLORIDA 33407 CUSTOMER NAME Regal Plumbing JOB NAME Ramos Res JOB ADDRESS 1071 South Header canal road ,Fort Pierce,F TRUSS PLACEMENT PLAN DATE DRW.BY SE 12/22/2020 SCALE 1/4 JOB # 201146