Loading...
HomeMy WebLinkAboutVandegrift gas line charts58-116 Tabld 16.1(a) PolpetWene P P - e UQ� �D PEnOLEUR GAS CODE, Plastic Pipe %x in. SDR s/ in. SDR 11 x 1..ength(Et.) 9.33(0.660) ! (0.860) (1.007) m rated Ga 1� Inlet Press„ re; 10.0 osigf Pressuore drop: 1.0 Psig Specific Gravitp: 1.52 1'/ in. SDR 11 1 f in. SDI. 11 2 (1.328) in SDR 11 (1.554) (19 1N'1'EN13ED USE: Sizing 1 +"�,: �' "ta : Pressure Regulator and Second -Stage 30 2140 7740 40 1840 .367 6630 13420 50 1'630 3260 1 5870 10480 180 60 1470 2950 5320 9220 70 1360 2710 4900 8480 80 1260 2530 4560 7890 90 1180 2370 4270 7400 100 1120 2240 4040 6990 125 990 990 3580 6200 150 897 897 3240 5620 175 826 826 2980 5170 200 778 778 2780 4810 225 721 721 2600 4510 250 681 681 2460 4260 275 646 646 2340 4050 300 617 1`'7 2230 3860 350 567 567 2050 3550 400 528 ,528 1910 3300 450 495 ! 495 992 3100 500 468 468 937 2930 600 424 424 849 2650 700 390 390 781 244440 2 800 363 363 726 0' 900 340 340 682 2130 1000 322 322 644 2010 1.500 258 258 517 933 2000 221 221 443 498 --1--- SDP-• Standard Dimension Ratio Notes: (1) Capacities are in 1000 Bw/hr. (2) Dimensions in parentheses are inside diameter. --1--- SDP-• Standard Dimension Ratio Notes: (1) Capacities are in 1000 Bw/hr. (2) Dimensions in parentheses are inside diameter. 43) GAS PIPING WSTALLATIONS Gas Undiluted Propane TABLE 402.4(28) Inlet Pressure 11.0 In, w.c. SCHEDULE 40 METALLIC PIPE Prossure Drop 0.5 in, w.c. Specific Gravity 1.50 INTENDED USE Pipe sizing between single- or socond�tage (low pressure) regulator and appliance. PIPE SIZE (inch) Nominal Actual ID Length (ft) 1/2 3/4 1 1'/4 1'1= 2 2'/2 3 E0.622 0.824 1.049 1.380 1.610 2.067 2A64 3.068 Capacity In Thousands of Btu per Hour 4.026 10 20 30 40 50 60 80 100 125 ISO175 175 200 25 300 350 400 450 500 550 600 700 700 750 800 850 900 950 291 160 160 137 122 110 101 94 89 84 74 67 662 58 51 46 42 40 37 35 33 32 30 29 28 27 26 608 418 287 255 231 212 197 I85 175 155 140 129 120 107 97 89 83 78 73 70 66 64 61 59 57 55 1,150 787 632 541 480 434 400 372 349 330 292 265 243 227 201 182 167 156 146 138 131 125 120 115 111 107 104 2,350 1,620 1,300 1,110 985 8 22 821 763 716 677 600 543 500 465 412 373 344 320 3 00 283 269 257 246 236 227 220 213 3,520 2,420 1,940 1,660 1,480 1,340 1,230 1,140 1,070 1,010 899 814 749 697 618 560 515 479 449 424 403 385 368 354 341 329 319 6,790 4,660 3,750 3,210 2,840 2,570 2,370 2,200 2,070 1,950 1,730 1,570 1,440 1,340 1,190 1,060 991 922 8 55 817 776 741 709 681 656 634 613 10,800 7,430 5,970 5,110 4,530 4,100 3,770 3,510 3,290 3,110 2,760 2,500 2,300 2,140 1,900 1,720 1,580 1,470 1,380 1,300 1,240 19,100 13,100 39,000 26,800 10,600 21,500 9,030 18,400 8,000 14,800 7250 14,800 6- 6,210 13,600 12,700 5,820 11,900 5,500 11,200 4,880 4,420 9,950 9,010 4,060 8,290 3,780 7,710 3,350 3,040 6,940 6,190 2,790 5,700 2,600 5,300 2,440 4,970 2,300 2,190 4,700 4,460 1,180 2,090 4,260 1,130 1,090 1,050 1,010 978 2,000 1,920 4,080 3,920 1,850 3,770 1,730 1,70 3,530 3,0 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000 For ST: 1 inch = 25.4 mm. 25 25 24 23 22 21 20 19 19 18 18 1 foot = 304 53 52 50 48 46 44 42 40 39 38 37 R rnrr, t remind 100 97 95 90 86 82 79 76 74 71 69 mar 206 200 195 185 1 66 169 162 156 151 146 142 e on, 309 300 292 277 2 44 253 243 234 226 219 212 595 578 562 534 5 99 487 468 451 436 422 409 948 921 1,680 3,420 1,630 3,320 895 850 811 1,580 3 23p 1,500 1,430 3,070 2,930 777 1,370 2,800 746 7320 2,690 719 1,270 2,590 694 0 1,190 2,500 672 1,,420 2 652 1,t50 2,350 1 British thermal unit per hour = 0.2931 W, I cubic foot per hour = 0.0283 m2/h, Ittdegree =00.01745 rad. kPa, Note: All table entries have been rounded to three significant digits. FLORIDA BUILDING CODE -- FUEL GAS, 6th EDITION (2017) Coght C 2ot� ICC. ALL RIGHTS RPSERVED. Accessed by Liny Silva on Ian 3o, 2oi a s:nasi AM Pursuant to Ucense Agreement with ICC No further reprodurt3 11114*1 pyrin or distribution outhortud. ANY UNAUTIiORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACTANDTHE LICENSE AGREEMENT, AND SUBIECTTO CIVIL AND CRIMINAL PENALTIES THEREUNDER. TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST) GAS PIPING INSTALLATIONS Gas Undiluted Propane Inlet Pressure 11.0 In. w.c. Pressure Drop 0.5 In. w.c. Specific Gravity 1.50 INTENDED USE: SIZING BETWEEN SINGLE OR SECOND STAGE (Low Pressure) REGULATOR AND THE APPLIANCE SHUTOFF VALVE B/ / JUBE SIZE (EHD) ® ® ( // Flow Designation 13 16 18 19 23 26 30 31 37 39 1 46 1 48 60 62 Length (it) Capacity In Thousands of Btu per Hour 5 72 99 181 211 355 426 744 863 1,420 1,638 2,830 3,270 5,780 6,550 10 50 69 129 150 254 303 521 605 971 1,179 1,990 2,320 4,110 4,640 15 39 55 104 121 208 248 422 490 775 972 1,620 1,900 3,370 3,790 20 34 49 91 106 183 216 365 425 661 847 1,4 00 1,650 2,930 3,2 00 25 30 42 82 94 164 192 325 379 583 762 1,250 1,480 2,630 2,940 30 28 39 74 87 151 297 344 528 698 1,140 1,350 2,400 2,680 40 23 33 64 74 131 153 256 297 449 610 988 1,170 2,090 2,330 50 20 30 58 66 118 137 227 265 397 548 884 1,050 1,870 2,080 60 19 26 53 60 107 1 126 207 241 359 502 805 961 1,710 1,900 70 17 25 49 57 99 117 191 222 330 466 745 890 1,590 1,760 80 15 23 45 52 94 109 178 208 307 438 69b 833 1,490 1,650 90 15 22 44 50 90 102 169 197 286 414 656 787 1,400 1,550 100 14 20 41 47 85 98 159 186 270 393 621 746 1,330 1,480 150 11 15 31 36 66 75 123 143 217 324 506 611 1,090 1,210 200 9 1 14 28 33 60 69 112 129 183 283 438 531 948 1,050 250 8 12 25 30 53 61 99 117 163 254 390 476 850 934 300 Fnr Cr• 1 inch=7S 8 A..,... 1 11 C--inn 23 0...- r 26 __ 50 57 •. -..,. 90 - . . 107 147 234 357 434 1 777 854 1,.,- I.�, aq.z- -". - v.o» r u, i-mcn water column = U.2488 kPa, 1 British thermal unit per hour = 0.2931 W, I cubic foot per hour = 0.0283 m'/h, I degree = 0.01745 rad. Notes: 1. Table includes losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length (feet) of tubing and n is the number of additional fittings or bends. 2. EIED-Equivalent Hydraulic Diameter, which is a measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing. 3. All table entries have been rounded to three significant digits. FLORIDA BUILDING CODE - FUEL GAS, Bth EDITION (2017) 67 Copyright 0 2017ICC. ALL RIGHTS RESERVED. Accrued by Lilly Silva on Jan 30, 2018 5:00:34 AM pursuant to License Agreement with ICC. No further reproduction or dlstrlbuaon authorircd. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACr AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CAI IN M AL FENALTIFSTHEREUNDER.