Loading...
HomeMy WebLinkAboutAPPROVED Walbeck NOA 3 4/23/2021 Florida Building Code Online Business & iYl „ tIF ProfessionalRegulation BCIS Home I Log In I User Registration Hot Topics Submit surcharge stats&Facts Publications Contact Us BCIS Site Map Links Search b a r Product Approval F�64� �` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail Opening #2 OFFICE OF THE FL# FL15210-R7 SECRETARY Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440)969-9773 Ext16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL15210 R7 COI (b)Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpiLejMsLBg%3d%3d 1/4 4/23/2021 Florida Building Code Online G 155 2005 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15210 R7 Equiv of Standards(c)_pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/21/2020 Date Validated 07/30/2020 Date Pending FBC Approval 08/05/2020 Date Approved 10/13/2020 Summary of Products FL# Model,Number or Name Description 15210.1 a. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series O Inswing/Outswing (X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.1 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.1.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.2 b. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.2 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.2.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.3 c. Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.3 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.3.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.4 d. Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door-Inswing/Outswing Grain/Rustic/Mahogany Series 0 (X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.4 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.4.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.5 e. Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (OX or XO; OXO-Configurations) Fiberglass Door https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpiLejMsLBg%3d%3d 2/4 4/23/2021 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.5 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.5.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.6 f. Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.6 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.6.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.7 g. Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door-Outswing (X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.7 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.7.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.8 h. Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Outswing (OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.8 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.8.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.9 i. Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites-Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.9.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.9 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.9.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.10 j. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door-Outswing(X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.10.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.10 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.10.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.11 k. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Outswing (OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.1i.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.11 for Design Pressure Ratings,any https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpiLejMsLBg%3d%3d 3/4 4/23/2021 Florida Building Code Online additional use limitations, installation instructions and product FL15210 R7 AE (c) Eval 15210.11.pdf particulars. Created by Independent Third Party: Yes 15210.12 I. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.12 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.12.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.13 m. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Surface Bolts Grain/Rustic/Mahogany Series O -Outswing (X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.13.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.13 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.13.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.14 n. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with Surface Bolts Grain/Rustic/Mahogany Series O on Active Door panel-Outswing (XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.14 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.14.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.15 o. Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door utilizing the Grain/Rustic/Mahogany Series O WINDSERTT"an operational window insert-Outswing (X- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.15.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.15 for Design Pressure Ratings,any FL15210 R7 AE (c) Eval 15210.15.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® 0] ® lid Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpiLejMsLBg%3d%3d 4/4 las ro P 6 re, -,j r- ��C) O 0'�� 01 5200 W. CENTURY BLVD. �;•' Z �''°; Z LOS ANGELES, CA 90045 : M CO M • •. ��, t P 37.50"MAX.OVERALL ���i� .i ��� o c ; z6 Smooth / Wood Gran / White Wood Gran FRAME WIDTH m c� N 0 Z 0z° q Rustic / Mahogany a C0 m W LL �'t 5g00m n' m d n. li -- - - - - - --- - -�/- --- - - - - - LL c N INSWING / OUTSWING o Ln CW J "IMPACT" N GENERAL NOTES CD z o 0 z 3 Wz Ln 1• - �� oQ Z O zo zw 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base O (D Y a g m material shall be beyond wall dressing or stucco. w = /� �w � w w N _jW dm Q Q� 3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code and < < Q does not require an impact resistant covering. J � o Q Q Q 4. When used in areas outside of the"HVHT'requiring wind borne debris protection,this product � a o complies with FBC Sections 1609.1.2& R301.2.1.2 and does not require an impact resistant covering. O O m This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC M Sections 1609.1.2.2&R301.2.1.2.1. CO m m CO 5. For 2x stud construction,anchoring of these units shall be the same as that shown for 2x buck masonry `� v construction. 0 0 N N oo z = 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a w w o licensed engineer or registered architect. oo � U_ 7. Outswing configurations meet water infiltration requirements for"HVHT'. All other configurations do '� ~ not meet the water infiltration requirements for the"HVHT'and must be installed only in non-habitable Q Q a areas or at habitable locations protected by an overhang or canopy such that the angle between 0- 0- the edge of canopy or overhang to sill is less than 45 degrees. o \� w tn TABLE OF CONTENTS o SHEET# DESCRIPTION SHEET# DESCRIPTION Z z1 Typical Elevations, Design Pressures &General Notes 8 Horizontal &Vertical Cross Sections (Direct to Masonry) MAX DESIGN PRESSURE (PSF) N o L„ CONFIGURATION FRAME z 2 Door Panel Details 9 3-point lock details DATE: 02/16/12 Z � 3 Lite frame details and glazing details 10 3-point lock details DIMENSION ` POSITIVE NEGATIVE, o SCALE: N.T.S. Uj 4 Horizontal &Vertical Cross Sections (2X Buck) 11 Buck and frame anchoring X DWG. BY: JK m s 5 Horizontal &Vertical Cross Sections (1 X Buck) 12 Components CHK. BY: LFS 3 6 Horizontal &Vertical Cross Sections (Direct to Masonry) 13 Bill of materials See sheets 2&4 for hardware and lice frame design pressure limitations DRAWING NO.: N 7 Vertical Cross Sections (Thresholds) a N c SHEET 1 OF 13 V O.T' 2.8" �� G1 G2 TOP RAIL ���•�, •����� to 0.4" — EXTERIOR 0.4" — (COMP.) ��•• '•�'�j LO tj-s ci 'n I*..<=z _j r., s d: 44 d' a a a. n d. •' s4 .: •; O K•'Q ..s ° .° ..s ° .° s. r Z Ort M to 00 ' a e ria up!5p a ``• a ''�//// ••••� Z O — . INTERIOR CAP (PVC) 'r i °' U N o Z CAP (PVC) LATCH STILE(LVL) ° •. a y E m° m HINGE STILE(LVL) $ v o a r 1 d° Otm N ----__— - a d �• a) D_ U. It. 2 y • C) d. CW N Ln • J h , d a o V) Of CN 35.75"DOOR HARDWARE TABLELn z o 0 WIDTH MAX.DESIGN N MANUFACTURER MODEL PRESSURE S vNi J w -. _ ; G1 ag m z � Q 2 KNOB: SIGNATURE SERIES cn w a 0 2 KWIKSET ± 75 m DEADBOLT: SIGNATURE SERIES(980) G2 a o KNOB: 7SERIES(F51) o SGHL +AGE DEADBOLT: "B"SERIES(B60/62) 75 0 �- PAMEX LEVER: FL3B SERIES INTERIOR EXTERIOR a-- °¢ CT //� DEADBOLT: FD7 SERIES ± 75 m CL - U a / c6 HOPPE MULTIPOINT LOCK: HLS9000 3-POINT TONGUE ± 50 �' �' C M m m n F LO ENDURA MULTIPOINT LOCK: TRILENNIUM 3000(3-PT) ± 75 a'V : • N N a = 1 Q •'a z >_ p See sheets 6 and 7 for multipoint lock details. • ' .6 . z = o Q SEE HARDWARE FIBERGLASS SKIN N a TABLE (0.125"MIN.THK.) `•° Q Q > o0 aFOAM CORE < ��/ (POLYURETHANE- • ..a• v'a _ F SEE HARDWARE 1.9 PCF MIN.) ui c TABLE • N rn Q LL :h • N O U Z BOTTOM RAIL : DATE: 02/16/12 °z a D (COMP.) SCALE: N.T.S. DWG. BY: X w m 2 � CHK. BY: LFS QI� 2 DRAWING NO.: N FL-15210.4 0 N SHEET 2 OF 13 0 v 011111111 ! *24.22"MAX. N. A ���r��� m FRAME WIDTH 5/8"GLASS BITE 4'• '� 20.50"MAX. � ••� � m STRUCTURAL SILICINE(DOW 995) =2�`t ° J- D.L.O.WIDTH A3 = s zz z LL EXT. 1"OVERALL GLASS THK. _ ;•V :`c �.- Q 1/8"ANNEALED GLASS N 1.86" - N 1.86" - 'i���••'••.., j`�� = o co co < U �! • ••`• m > F) rn o O 0.090"SAFLEX®PVB � 0 N 0D z° INTERLAYER 41 X o Q 1/8"ANNEALED GLASS j Lq € z m° m u? AIR SPACE m,) 5 o r m "' u' = 5 1/8"TEMPERED GLASS a m ° ° `` (TYP•) FRAME :FRAME m c ° a ALUMINUM SPACER g��. g4ylE 0 z N Q 40 NON STRUCTURAL SEALANT o 3 7< A4 #7-19 X 1-3/4"PPH SELF-DRILLING SMS Q 10 INT. N Mcli 10 co N �A U- J LL 0 V) a �� m �N LtTE FRAME TABLE o `�w LL0 4.25" MANUFACTURER - MAX.:DESIGN' n m Q �o (TYP.) PRESSURE SF)::;� _,Q OD! LITE FRAME ODL ± 75 0 Q c 24"MAX. cr FRAME WIDTH RSL ±CL 60 > m ° 20.75"MAX. c D.L.O.WIDTH m m N N d EXT. cn N O 1/2"GLASS BITE z > � Q A5 ww o 1-1/4"OVERALL THK.GLASS STRUCTURAL SILICINE(DOW 995) � ix In _LD —�- 1/8"ANNEALED GLASS 00 r = 0.090"SAFLEXOPVB ¢ ¢ � O 6 INTERLAYER 1.59" 4 CL ❑ a (nP') 1/8"ANNEALED GLASS ul Q Q 1.06" C) c ,�o 01, AIR SPACE ^ o ° ¢ C-i^ 1/8"TEMPERED GLASS ^jj Z LL ,�o 1 N Z v 'O L, a- 1/2"NON-GROOVE SWIGGLE A7 40 z W W/DELCHEM#80 POLYSULFIDE S� 1.5" DAB: 02/16 12 0 1/8"BACKFILL A6 SCALE- N.T.S. uj L #10 X 1-3/4"PPH WOOD SCREW DWG. BY: JK 00 NI Q, EXI:FRAME INT.FRAME SCREW CAP INT. G2 GLAZING DETAIL A5 A6 A7 cHK. eir: LFS ft DRAWING NO.: N (TYP) FL-15210.4 0 N RSL LITE FRAME N SHEET 3 of 13 cu 10 K 3 3 3 5 6 LO U. 'zz:z Q o � � rn �.. z z 0rn • t M ` z o w o U N Z O + x 0 Q v Z Z 0 V of a !�M � � 03 m aaa m ® cLL 2 A 0 =z £ o N 0 Q 'T U C W 4 2 0 �o: 5 2 Um j/ 6 0 LL ; �` 2 Z o >.xN. 8 �cn �z 8 a.g M ¢o 3 4 D 4 1-1/4"MIN. g(D Q ocW 8 EMB. (TYP.) a.m a N 8 cn N E a cn g 1 2 3 2 D o Q =0 C 7 7 7 0.15° B Q pa a a cr a s L C'SINK - C >- 0 o a (TYP.) O -� -�m 0.15 C-SINK e ° (TYP) ° E m m 21 a 1 2 INTERIOR ° n a ° N N c o (n D z ° d ° D W W O d D N a n 7 7 L co LO LaJ D A d' CO 0 O °- n a (L CL p Q n D ° 0. ° o c N Q F fo 40 o ° N 7 z o 0 LL ° 58 ° F >> EXTERIOR a N " z El W 4 EXTERIOR INTERIOR DATE: 02116112 i 27 a 1-1/4 MIN. L 9 E ci SCALE: N.T.S. EMB. (TYP.) o ° o DWG. BY: JK m 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION CHK. BY: LFS 3 4 Outswing shown (Inswing similar) 4 Outswing shown (Insw(ing similar) 4 Outswing shown (Inswing similar) DRAWING NO.: FL-15210.4 0 SHEET 4 OF 13 v �� •�` ,. n =g� o. ..►:(3 M M -' r z k;: O m �i //11 111 U N x U Q QCO 0 U V . V)� tm Ln M LL.� m a a a 3 O G O C v O C Li C. A o >a I E LL C Y J C� CD 2 1 C vm ZQ to E °�Z M JO V E ° .. p Qm N(n e � O 00 @ 7 7 INTERIOR 40 G C z > ?>- Cr d A a m n `L n — W d- 0 O1 N N 2 p rn ° v D Ln CU Q° Z EXTERIOR 7 1 2 = _ 27 G A o to 1-1/4'MIN. 9 40 EXTERIOR INTERIOR '- '- EMB.(TYP.) 1-1/4 MIN. EMB. (TYP.) o 0 0 � z CL 1 2 3 _ �n w/1 X sub-buck § Shown w/ 1 X sub-buck Shown w/1 X sub-buck a 5 Outswing shown (Inswing similar) Outswing shown (Inswing similar) Outswing shown(Inswing similar) MnN °' o j h N m z o Z. O a DATE: 02116112 z z scALE: N.T.S. w Z a DWG. BY: JK m w CHK. BY: LFS 3 v DRAWING NO.: FL-15210.4 0 SHEET 5 of 13 a c a U U * i4=z J •_ Nw o •�.": �+ obi �. Z co Z U M_ 0) m U N •• Lv 0 x Z a { Ld 0 () U` a tn� cm .o .� M an. tL o' c c 0 v o 0 o c W C�G N � Jed. ` J Ln LL E E 2 1 �z C o C o_ Q g N z� VO ul� N Q 17 Cn - ° C� U 1 2 a D D � W �o W S� �ca zz 7 E ° --�- �-- o NNo ° ] ° o ° ® ' o 8� Qw M e INTERIOR 40 p a =cn B ° e � Ym CL O o t C UU E ° ° v m IT, m m O O 0 40 N N � N EXTERIOR 1 2 w w o 11 40 27 M EXTERIOR INTERIOR o o Ln 9 f- F- J `'A 1-1/4"MIN. 1-1/4"MIN. EMB. TYP. o 0 a ( )EMB. (TYP.) = 0- °z a 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION " `�' w Z 6 Shown Direct to Masonry 6 Shown Direct to Masonry 6 Shown Direct to Masonry Outswing shown (Inswing similar) Outswing shown (Inswing similar) Outswing shown (Inswing similar) N o N . z U OI z DATE: 02116 12 z a SCALE: N.T.S. wDWG. BY: JK M n u CHK. BY: LFS 3 o DRAWING NO.: FL-15210.4 0 SHEET 6 OF 13 O c v U — U o * :�=Z � rn_ ( 1c'. �W3 Z A z nrnn 03 U N 41_ 0 XZU `o Ern o m m IxO* -j o o a. m C � z° EXTERIOR INTERIOR 0 0 C W ° • a° 3'a Ln J LL n N C) Cq Ln 8 40 Zo �W —71 29 �� m 7 m W(no E=� oc En o=Z En w C-WN ¢ >� EXTERIOR INTERIOR Q d EXTERIOR INTERIOR 0 0 e o0 of d, e d M 40 d Cr M O. e e n d O 30 31 32 33 34 40 8 E 2 VERTICAL CROSS SECTION N 7 Shown w/ADA threshold 36 h o0 v' 37 N N Z 38 Eaw o N E d - e o c e a. e ti CL C] 4 a o ,t\ fit) H e 8 e d A c � Q a N Cn Q t J En 1 3 VERTICAL CROSS SECTION � Z d7 Outswing confirguration 7 Inswing configuration N z 0 DATE: 02116 12 -Z z W z o SCALE: N.T.S. J a Uj DWG. BY: JK m W u CHK. BY: LFS 3 "" DRAWING NO.: o �0 FL-15210.4 0 SHEET 7 OF 13 c d U A. Z " O:'•• m M � ~ MAX. 'v � 2. MAX. __;� � Q;NO =z M Cd 1.25" E W 1.5" — V? c :Z�— U- rn E w MIN. MIN. MAX. �N' z �;:Q� to ' P �j �1•••••• l `` J D t0 00 //H 11j1 M W O Z C C >) UN0 _ ° z_ 0Zv c Ern omm Q1W40 � man. LL `E 0 Z T _ CW EXTERIOR INTERIOR EXTERIOR INTERIOR J a r-J a: .zo N S VERTICAL CROSS SECTION G VERTICAL CROSS SECTION o $ Shown Direct to Masonry $ Shown Direct to Masonry Zoe >o Outswing only wl 4-9/16'jamb Outswing only w/6-9/16'lamb f L:s In �� �W LOU W U) O� v c1 nD Q N 0z p r. W ¢ cWn QQ a a X Cr - X 7 m 0 i[� Q icy LQ Q f � m m U- Li N Cr> Z LO o, fV N INTERIOR '— 00 N N N 40 40 0 o z p� p d p; qp - p d 4_ W W O INTERIOR o N to to `D (',j Ln `r N 40 40 N N o o ti � n M M N M "' a R0 Q o a 1-1/4"MIN `�' . N EMB. (TYP.) w z m N � Q � o D ° EXTERIOR E Z N EXTERIOR E N " z 0 W 1-1/4"MIN. 1-1/4"MIN. M 1-1/4"MIN. DATE: 02116112 z EMB.(TYP.) EMB.(TYP.) EMB. (TYP.) Ste; N.T.S. W 4 HORIZONTAL CROSS SECTION DWG. BY: JK 3 HORIZONTAL CROSS SECTION s 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION g Shown Direct to Mason CHK. BY: LFS 3 $ Shown Direct to Mason Shown Direct to Mason 8 Shown Direct to Mason g y /6-9/16Y'amb �; 8 ry Outswing only w/6-9/16"jamb Outswin only w 1 DRAWING NO.: N Outswing only w/4-9/16 jamb Outswing only w/4-9/16'jamb FL-15210.4 0 SHEET 8 OF 13 N U to yy i'Q 'Z r frd' Z ••�` Z U � Q *c to M �I ........... �,�i.� 1 8 tD 00 Z M OD Z m U 04 .. J ta,�� � v Em 0 xZQ In 0 0 0 v� v - 06a a O mao wLL cn v E D C Z j 0 2X BUCK 5$ o° ._'ci'Uj a 0 Co R 1 X BUCK G 0 0 DIRECT TO M%e 0 MASONRYC) A c 0 0 �J zo cM 0:�V) J �� t m � Ln Uq o nm � w O Q 2X BUCK 5$ w w HOPPE MULTIPOINT LOCKSET 25 0 0 22 �; 1 X BUCK G 0 a •m HLS9�3-Point'Tongue" a a tl� DIRECT TO M •' A MASONRY > > m 00 E —►j 1.7" 2X BUCK 5$ 1 I h t F I BUCK G 00 DIRECT TO M 23 c5 o z N MASONRY w w o 22 0 � i �2 w wa< w �`' lu-j J 1., 00 ® Jj > > z Q co F w z 0 STRIKE JAMB ^ o N v Z LL V' cl) U Z ° DATE: 02 16112 z ta w O ® SCALE: N.T.S. 9 Z DWG. BY: LU a CHK. BY: LFS 3 23 MULTIPOINT STRIKE PLATE 25 LATCH AND DEADBOLT STRIKE PLATE DRAWING No.: o Tongue system FL-15210.4 N MANUAL RAISED TONGUE GEAR SYSTEM ° SHEET 9 OF 13 N w 0 c a U �. U z ��:• �; O O) M 00 M zo o 00 z° o c� N04 55 ``s o z 0 E p m c CL c W 0 0 c�� m0 nm m ' o =Z �o • O :� • 0 C W o O JLn N J LL rCD N O .0 Ln N z ti Y 'n Cq �� O El m ate-.g m v Z o d a N = O m Q • " O O w Q � •° d d 0 7 7 m CL O ' U U o m m N et n � � N O O o cy 57 N N a� to N bQ w w o > ? �,s V) 62 � t o � ao - Q o • ° q iw- CL OU.. ci a 2XBUCK 58 ° T = N m 1 X BUCK G N Cb a F d DIRECT TO M z Z5 MASONRY N z 0 F DATE: 02116112 z z SCALE. N.T.S. DWG. BY: UK 6 Lu ENDURA TRILENNIUM 3000 STRIKE JAMB DETAIL CHK. BY: LFS DRAWING NO.: Ir a 3 pt.Lock FL-15210.4 0 a SHEET 110 OF 13 y a-' C °J U RECT TO 4 4-9/16"JAMB P DSIEE SHEET g MASONRY JAMB (TYP.) ���`� ��,-1 to (TYP.) d„ ; 4:' 10 a a a (TYP.) ,k z r LL J ♦ i- OS y: Z 2 aj to 4 if « a �!!!!! 1111� Z 6; d �* SEE HINGE L 2X BUCK 10 °- N z � � � 0 X D TYP. HEAD Ci DETAIL (TYP.) �y &JAMBS C>. G 1 X BUCK v �0 m `o a DIRECT TO o a in V) m a a m MASONRY D MASONRY MASONRY o ® c d OPENING OPENING TYP. HEAD E 0 Z N M &JAMBS o J a FRAME Z ' X iL C Q o N • U UQ V 2X BUCK Ln 4-9/16"JAMB M r zo 2X BUCK ~6-9/16"JAMB N Of Co M w o < °' DIRECT TO o am �, MASONRY ¢ JAMB (TYP.) o o U (SEE SHEET 8) 0 Q m cr m • ' ADA SILL > > m n v o ONLY ' mm C •— E rn n v< U7 _ STRIKE JAMB HINGE JAMB w w o _ Masonry construction CONCRETE ANCHOR NOTES: DIRECT TO ¢ Q 0 1. Concrete anchor locations at the corners may be adjusted to maintain the min. DIRECT TO MASONRY M DIRECT TO 2 edge distance to mortar joints. M MASONRY M a 2. Concrete anchor locations noted as'MAX.ON CENTER"must be adjusted to MASONRY o a 1 X BUCK G In t maintain the min.edge distance to mortar joints,additional concrete anchors 28 1 X BUCK 1 X BUCK G '- �2 w z omay be required to ensure the'MAX.ON CENTER dimension are not exceeded. G 9 9 Z 2 3. Concrete anchor table: 2X BUCK L Q j v M1N.CLEAR9NCE MIN.CLEARANCE ZX BUCK 58 5$ 2X BUCK 2X BUCK L N o ANCHOR ANCHOR1N TO MASONRY TO ADJACENT 1 TYPE SIZE EMBEDMENT EDGE ANCHOR 11 `V Z trw 1 X BUCK 11 DIRECT TO DATE: 02/16/12 z z iAPCON® 1/4" -114" 2" 4 DIRECT TO p M MASONRY >> SCALE N.T.S. 9 MASONRY G 1 X BUCK DWG. BY: JK m 1Tw ® 3/16" t-1J4" AS SHOWN 1-1J2 27 58 2X BUCK CHK. sir:LU LFS 3 TAPCON DRAWING NO.: 1, WOOD SCREW INSTALLATION NOTES: LATCH&DEADBOLT DETAIL HINGE DETAIL HINGE DETAIL FL-15210.4 N m Maintain a minimum 518"edge distance, 1"end distance,& 1"o.c.spacing of Inswing Outswing N . wood screws to prevent the splitting of wood. SHEET 11 OF 13 Y O v U // 0. to 4.56" 4.6" to O. 4.56" r`n. o X! to z * .Q 0)�. F- 0 0) ,n V'• � Q 0 _ ro Lf) I-� 2.441' ► . 2.13 ;; c) 04 OtTTSWING THRESHOLD z Z v OLITSWING THRESHOLD POLY FIBER JAMB E 0, m m $d DLP(QOSR) Columbia High Dam(581) Plastpro a N M o °c m m a�a � 3 y u CJ o c c 0 N Cli 4.69' 4.56° ^ CO �a 0 4.T' J LL LO CV N 60 Z I Z 2.36' - I-—2.2" 3 3Z OUTSW/NG THRESHOLD 31 OUfSWING THRESHOLD W M DL o o P(QOSH) Columbia(575) 2 WOOD JAMB v O N is o o w Q 0_ o —S.b2" —5.b3" 0 2.088" r o � m '� � U U n � m m CDrbLN N -- ( 0.52 (-+- > *ColumbiaINSWING THRESHOLD WEATHERSTRIP DOOR BOTTOM SWEEP w w o OUTSWING THRESHOLD 0 33 Endura(Z-Series) Endura Force 5 8 to LO oo � N WLU CL 00 j cL o a 4.56' w �' w F t 5.625' Ci Z o NMQ -4.56" I,, r7 N o _ Z __ o Z 0 z � .. � _ ��c � � DATE: 02116112 � z SCALE: N.T.S. o a $6 INSWING THRESHOLD INSWING THRESHOLD 29 ADA THRESHOLD DWG. BY. JK m' 37 DLP CHK. BY: LFS Endura(Mertes) DLP(ISCS) DRAWING No.: cL FL-15210.4 N y SHEET 12 OF 13 ON c a U to ��••. oo BILL OF MATERIALS •`. °�'••' i o •o•j U n ITEM# DESCRIPTION MATERIAL =V �r iC ;�= rn A 1 X BUCK SG>=0.55 WOOD "s Z 4110 v, B 2X BUCK SG>=0.55 WOOD �� •• �.gy` o; " C 1/4"MAX.SHIM SPACE - J D 1/4"X 2-314"PFH ELCO OR ITW CONCRETE SCREW STEEL tttti •��� � z o ao o E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI N 0 z 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE ° z o z cai G 3/1,6"X 3-1/4'PFH ITW CONCRETE SCREW STEEL a o m zo cW I 1/4 X 1-3/4' PFH ELCO OR ITW CONCRETE SCREW STEEL L m a a m J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL K 1/4"X 2-1/4 ITW CONCRETE SCREW STEEL o Z 0 N L #10 X 2-1/2"PFH WOOD SCREW (1.15"MIN. EMBEDMENT) STEEL o 3 a ull M 3/16"X 2-1/4"ITW CONCRETE SCREW STEEL N 3/16"X 2-3/4"ITW CONCRETE SCREW STEEL N P 1/4"X 2-1/4"PFH ELCO CONCRETE SCREW STEEL 1 POLY FIBER JAMB COMP./VINYLLn zo 2 FINGER JOINTED PINE FRAME WOOD 7 WEATHERSTRIP FOAM a m 8 DOOR BOTTOM SWEEP VINYL cn� w o 9 4"X 4"BUTT HINGE STEEL Qm Q 11 #9 X 3/4"PFH WOOD SCREW STEEL `` On " 22 3 POINT'TONGUE"MULTIPOINT LOCKSET (Mfg. BY HOPPE) STEEL o 0 23 MULTIPOINT STRIKE PLATE (TONGUE SYSTEM) STEEL ~ o a 25 LATCH AND DEADBOLT STRIKE PLATE (TONGUE SYSTEM) STEEL o a 27 LATCH STRIKE PLATE STEEL > > m t 28 DEADBOLT STRIKE PLATE (SECURITY) STEEL ru C 29 ADA THRESHOLD ALUM mm 30 OUTSWING THRESHOLD ALUM/WOOD Em 31 OUTSWING THRESHOLD ALUM/WOOD N N 32 OUTSWING THRESHOLD ALUM/WOOD z = 33 OUTSWING THRESHOLD ALUM/COMP w w o 34 OUTSWING THRESHOLD ALUM/WOOD ALUM/COMP Ln 36 INSWING THRESHOLD LL 37 INSWING THRESHOLD ALUM/WOOD o fu 38 INSWING THRESHOLD ALUM/COMP o 0 a 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS - 6 Z 55 #10 X 1-1/2"PFH SCREW STEEL STEEL z 57 BACKING PLATE N rn Q F 58 #8 X 2"PFH WS STEEL �, o LL 60 MULTIPOINT STRIKE PLATE STEEL z N 62 ENDURA TRILENNIUM 3000 LOCK ASSEMBLY STEEL z rl Z DATE: 02116112Lu Z SCALE: N.T.S. W DWG. BY: X m' a CHK. BY: LFS 3 o DRAWING NO.: CL FL-15210.4 N ra 0 N SHEET 13 OF 1_3 c v U