HomeMy WebLinkAboutNotice of AcceptanceMIAMI-�E " MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) wwwaniamidade.Qov/building
CGI Windows and Doors, Inc.
3780 W 104" Street
Hialeah, FL 33018
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product
or material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series "Sentinel 110" Aluminum Single Hung Window — L.M.I.
APPROVAL DOCUMENT: Drawing No. SH110-LM-NOA, titled "Series 110 Alum. Single Hung Window
(LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision
stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control
Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant.
LABELING: Each unit shall bear a pennanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA# 17-1018.08 and consists of this page 1 and evidence pages E-1, E-2,
E-3, E-4 and E-5, as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez, P.E.
NOA No. 20-0722.09
Expiration Date: September 22, 2025
Approval Date: September 10, 2020
T9/1/20 Page 1
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No. 10-0510. 11)
2. Drawing No W10-03, titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)",
sheets 1 through 9 of 9, dated 02/02/10, with revision D dated 09/29/17, prepared by
Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
(Submitted under NOA No.17-1018.08)
B. TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 7500 PVC fixed
window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer®
insulating glass spacer, prepared by Certified Test Laboratories, Test Report No.
CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0512.09)
2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 7400 PVC project
out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super
Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report
No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0512.09)
3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 238 aluminum
fixed. window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super
Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report
No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0512.09)
Manuel Perez, P.E.,
Product Control Ex " r'
NOA No. 20 0722.09
Expiration Date: September:
Approval Date: September 10, 2020
E-1
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED)
B. TESTS (CONTINUED)
4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, TAS 202-94
along with marked -up drawings and installation diagram of a series "Sentinel"
aluminum single hung window, prepared by Hurricane Test Laboratory, LLC, Test
Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J.
Abraham, P.E.
(Submitted under NOA No. 10-0510.11)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 61n
Edition (2017), dated 09/29/17, prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
(Submitted under NOA No.17-1018.08)
2. Glazing complies with ASTM E1300-09
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on
07/04/ 18.
2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17,
expiring on 07/08/19.
3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA)
for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core" dated 09/07/17, expiring on 12/11/18.
4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on
05/21/21.
Manuel Perez, P.E1
Product ControA l Ex r
NONo. 20 0722.69 '
;xpiration Date: September , 2
Approval Date: September 10, 2020
E-2
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED)
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 5" Edition (2014), and of no
financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed
by Javad Ahmad, P.E.
(Submitted under NOA No.17-1018.08)
2. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by
Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu
J. Abraham, P.E.
(Submitted under NOA No. 10-0510.11)
3. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as
well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass
spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by
Jaime Gascon, Supervisor.
(Submitted under NOA No. 15- 0512. 10)
G. OTHERS
1. Notice of Acceptance No. 15-0512.10, issued to CGI Windows & Doors for their Series
"Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 08/06/15 and
expiring on 09/22/20.
If MEIiY�W. I .
Manuel '1'erez; P.E.
Product Control Ex r
NOA No. 2 0722.09 '
Expiration Date: September, , 2
Approval Date: September 10, 020
E-3
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No SII110-LM-NOA, titled "Series 110 Alum Single Hung Window (LM)",
sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by
manufacturer, signed and sealed by Anthony Lynn Miller, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per ASTM F588 and TAS 202-94
along with marked -up drawings and installation diagram of all PGT Industries, Inc.
CGI Windows and Doors, Inc., representative units listed below and tested to qualify
Dowsi1791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by
Fenestration Testing Laboratory, Inc., Test Reports No.:
PGT Industries, Inc. test specimens:
FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14
FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal)
FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal)
FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and
FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal)
all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E.
CGI Windows and Doors Inc. test specimens:
FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal)
FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal)
FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal)
FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and
FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)
all dated 08/24/20 and signed and sealed by Idalmis Ortega, RE
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 7tn
Edition (2020), dated 07/11/20, prepared by manufacturer, signed and sealed by
Anthony Lynn Miller, P.E.
w�
Manuel erez,,P.E
Product Control Exaf e
d. NOA No. 2 O( 722.0
Approval Date: September 10, 2021
E-4
CGI Windows and Doors. Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED (CONTINUED)
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their
"Kuraray SentryGlas® XtraTM (SGXTm) Clear Glass Interlayer" dated 05/23/19,
expiring on 05/23/24.
2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19,
expiring on 07/08/24.
3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA)
for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core" dated 05/17/18, expiring on 12/11/23.
4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on
05/21/21.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 6" Edition (2017) and the
FBC 7" Edition (2020), dated July 16, 2020, issued by manufacturer, signed and
sealed by Anthony Lynn Miller, P.E.
2. Statement letter of no financial interest, dated July 16, 2020, issued by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10,
2020, signed by Ishaq Chanda, P.E.
4. Notification of Successor Engineer for manufacturer's NOA document per Section
61G15-27.001 of the Florida Administrative Code, notifying original engineer that
the successor engineer is assuming full professional and legal responsibility for all
engineering documents pertaining to this NOA, dated July 16, 2020, signed and sealed
by Anthony Lynn Miller, P.E.
5. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10,
2020, signed by Ishaq Chanda, P.E.
G. OTHERS
1. Notice of Acceptance No. 17-1018.08, issued to CGI Windows & Doors for their
Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on
12/21/17 and expiring on 09/22/20.
Manuel Perez, P.
Product Control EE0722.
"
NOA No. 20Expiration Date: September
Approval Date: September 10, 20
E-5
mi
AP
FLANGE & FLANGE ADAPTOR FRAME
SERIES SENTINEL 110 ALUMINUM SINGLE HUNG WIND0�
LARGE & SMALL MISSILE (LM & SM)
DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2.
EQUAL LEG FRAME
INTINS
APPDE
FIN FRAME
APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WINDOW WITH OTHER
CENTER ANCHOR REQUIRED WHEN
MIAMI-DADE COUNTY APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN
SPACING EXCEEDS 20 9/16"
PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM.
THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) AND 2020 (7TH
EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).
LAMINATED GLASS
1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED
INSULATING LAM. GLASS
PRODUCT LOADS TO THE BUILDING STRUCTURE
SMALL MISSILE IMPACT
ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF S INSTRUCTIONS. SPECIFIED
LARGE MISSILE IMPACT
EMBEDMENT TO BASED MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.
A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY
ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE.
MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL
MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS.
THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS
PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE, ETC.
CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL
REVISED FOR 2020 FBC,
ADDED ANCHOR TYPE,
BACKBEDDING &
REFORMATTED - JR -
07/07/20
N
Y
Q
•nay
W
UJ
°SON
O
2
O
i
z¢ "
zo z
o_
z
} J p
m
Uma'o
o z E!
�
Woo.
Q�ZmP
oN
c
z
JM0
rn
LL
a z
7
S
y
W
J
O
Z
C)
y C
Z
zi
OC 3so
z
e aye
m
ZO
~
z
IL
z�=
W
Q
o
0
Vn=M
N
W
apq
•asap
s ua$
r LY,V jar ,
a , L,cevsr ••�(�,
No.58705 N
1 A7E F CL/�
'S8/0NAL E�
A LYNN MILLER, RE
P.E.# 58705
EQUAL LLTB.S WINDOWS
DESIGN LOAD CAPACITY - PSF
FIANCE DIMS.
BUCK DIMS,
GIA99 TYPE 'A'k'Al'
GIA89 TYPE 'B'k'Bl'
WIDTH
HEIGHT
WIDTH
HEIGHT
EXT.(+)
INT.(-)
EXT.(+)
TNT.(-)
19-1/8'
26-1/2'
37'
49'
53-1/8'
26'
18-1/8'
25-1/2'
36'
48'
52-1/8'
25'
75.0
75.0
80.0
85.0
75.0
75.0
80.0
85.0
75.0
75.0.
B0.0
85.0
75.0
75.0
50.0
85.0
75.0
75.0
80.0
65.0
19-1/8'
26-1/2'
37'
49'
53-1/8'
38-3/8'
18-1/8'
25-1/2'
36'
48'
52-1/8'
37-3/S'
76.0
75.0
80.0
85.0
75.0
75.0
80.0
B5.0
75.0
75.0
80.0
85.0
75.0
75.0
80.0
B5.0
75.0
75.0
80.0
85.0
19-1/8'
26-1/2'
37'
49'
53-1/8'
50-5/8'
18-1/8'
25-1/2'
36'
46
52-1/8'
49-5/8'
75.0
75.0
80.0
85.0
75.0
75.0
80.0
85.0
75.0
75.0
80.0
85.0
75.0
75.0
80.0
85.0
75.0
75.0
80.0
85.0
19-1/8'
26-1/2'
1.
49'
53-1/8'
63'
18-1/0'
25-1/2'
36'
48'
52-1/6'
62'
75.0
75.0
80.0
85.0
75.0
75.0
80.0
65.0
75.0
75.0
80.0
85.0
75.0
75.0
80.0
85.0
75.0
75.0
80.0
95.0
19-1/8'
26-1/2'
37'
49'
53-1/8'
76'
16-1/6'
25-1/2'
36'
48'
52-1/8'
75'
75.0
75.0
00.0
85.0
75.0
75.0
80.0
B5.0
75.0
78.0
80.0
85.0
75.0
75.0
B0.0
85.0
75.0
75.0
00.0
85.0
19-1/8'
26-1/0
37'
46-1/2'
�•
18-1/8'
25-1/2'
36'
45-1/2'
w
75.0
75.0
90.0
B5.0
75.0
75.0
80.0
65.0
75.0
75.0
80.0
8.5.0
75.0
75.0
813.0
85.0
WIDTH
0
x
EQUAL LITES
NOTE:
GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM
E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION
DECLARATORY STATEMENT DCA05-DEC-219.
UNEQUAL LLTES WINDOWS
DESIGN IOAD CAPACITY - PSF
FIANCE DU®.
BUCK DILLS.
KMTOP IIfE
GLASS TYPE 'A'YAl'
GLASS TYPE 'B'k'Bl'
WI01H
HEIGHT
WM
HEIGHT
'A' DIM.
-(+)
I -(-)
EIR.(+)
INI.(-)
53-1/8'
76'
52-1/8'
75'
36-1/4'
75.0
75.0
60.0
85.0
49'
79
48'
78'
39-1/4'
75.0
75.0
80.0
85.0
26-1/2'
31'
33'
V.
43'
85'
25-1/2-
W.
30
36'
42'
84'
70-5/8'
75.0
75.0
80.0
85.0
63-5/8'
75.0
75.0
80.0
85.0
60'
75.0
7&0
90.0
85.0
53-1/2'
75.0
75.0
60.0
85.0
45-1/4'
75.0
75.0
60.0
85.0
UNEQUAL LITES (ORIEL TYPE)
Yt' NP. w TYP.
BUCK DIMS
FLANGE FRAME
FLANGE DIMS _I
BUCK DIMS
G
BUCK DIMS
FIN FRAME
BUCK DIMS
FLANGE ADAPTOR FRAME
FLANGE DIMS
UNEQUAL LITES (ORIEL TYPE)
pkA r ILYNN "',,
No. 58705
L lEl����
A L>{Ah IAhIlLER, P.E.
P.E.# 58705
.075' Saflex CP With PET Core
.075" Saflex CP With PET Core
By 'Eastman Chemical Co.'
By 'Eastman Chemical Co.'
.090" Saflex Clear And Color Glass
¢
.090' Saflex Clear And Color Glass
gBy
'Eastman Chemical Co.'
>
g
By 'Eastman Chemical Ca:'
.090" SentryGlas®
.090' SentryGlas9
'Kuraray
By 'Kuraray America, Inc.'
By Americo, Inc.'
1 8- ANNEALED GLASS
/
.090" Trosifol PVB
By 'Kuraray Ameica, Inc.'
1/8' HEAT STREN'D GLAS
.090* Trosifol PVB
y 'Kuraray Ameica, Inc.'
1/8- ANNEALED GLASS
1/8- HEAT STREN'D GLASS
p.
F
SILICONE,
SILLCQNE:
m
M1
GE 1200
DOW CORNING 791.
899, 983 & 995
= m
M1
GE 1200
DOW CORNING 791,
899, 983 & 995
N �
\ /
� C.,
\
a /
0
EB
1
GLASS TYPE 'A'
5/16" OVERALL LAM. GLASS
(L.M.I & S.M.I.)
.075" Saflex CP With PET Core
By 'Eastman Chemical Co.'
1/8- ANNEALED GLASS
w .090" Saflex Clear And Color Glass
3 By 'Eastman Chemical Co.'
1/4- AIR SPACE
w .090' SentryGlas®
By 'Kuraray America, Inc.'
1/8- ANNEALED
.090' Trosifol PVB
OR TEMPERED- GLASS
By 'Kuraray Ameica, Inc.'
1/8" ANNEALED GLASS
c
SILICONE:
a
GE 1200
N
DOW CORNING 791,
/899. 983 & 995
XL EDGE SPACER
ST. STEEL BY 'CARDINAL'
OR
0 DURASEAL BY 'QUANEX'
OR
1 SUPER SPACER BY 'QUANEX'
GLASS TYPE 'Al
0.70' OVERALL INSUL LAM. GLASS
(L.M.I & S.M.I.)
ES
1
GLSS TYPE 'B'
5/16- OVERALL LAM. GLASS
(L.M.I & S.M.I.)
.075" Saflex CP With PET Core
By 'Eastman Chemical Co.'
1 /8' HEAT STREN'D GLASS
.090" Saflex Clear And Color Gloss
gBy
'Eastman Chemical Co.'
1/4" AIR SPACE
.090' SentryGlos®
By 'Kuraray America, Inc.'
1 /8' HEAT STREN'D
.090' Trosifol PVB
OR TEMPERED+' GLASS
By 'Kuraray Ameica, Inc.'
1/B" HEAT STREN'D GLASS
c
SILICONE'
z
m
GE 1200
DOW CORNING 791,
N
M1
899, 983 & 995
c7
XL EDGE SPACER
ST. STEEL BY 'CARDINAL'
OR
O
DURASEAL BY 'QUANEX'
a
OR
SUPER SPACER BY 'QUANEX'
1
'Elf
GLASS TYPE
0.70" OVERALL INSUL LAM. GLASS
(L.M.I & S.M.I.)
• FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LITE (CAP) MUST BE TEMPERED.
ADDED BACKBEDDING
TYPES - JR - 07/07120
p
N
Y
Q
n
nab
t
w °
O
o
Ma
0
0
Q
N
r�ry
w
Z
p
¢Qv
ZE:
O
v
W=W W
Z
Q i.
°N
u
Wo>�
Z
9M0
=
LL
Dt
0
_ N Z
0
0
� �
y G
Z
U)
7aa4'
o
.fi x oW
�.
�+ o z
6
0
F
v
ro m
a= "�xr+
E3 oQLL°
�
H
o_
0
Z
w
rn
zi=
W
U)
o
0oL�
g
Un=M
U
rp
\j111LLIIliff7j
` ONY LYNIV4�f
* No.58705
--05TR
i
A'� `S�ONAL E�.•
A &r4m l-LIW, P.E.
P.E.N 58705
IN
WOOD BUCK l
.,d• QA.
.e � aa.•
O
O
E4 n
I
i
i
F�
0
�i
R+
W N
� 54
w �I
I
M9 .
1
EDGE
DIST.
1BY
W00D BUCK
FOR SPACING
I
£DG R015T.�
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
.• • " a
TYPICAL. ANCHORS
SEE ELEV.
FOR SPACING
FLANGE & FLANGE ADAPTOR FRAME
:AL ANCHORS
ELEV.
SPACING
2 3/�r�
JJJJ����III!! 2 3/����LL
WHEN USED THE MIN. WOOD BUCK
DEPTH SHALL BE 2%". THE USE OF
DEEPER OR BEVELED WOODBUCKS IS
PERMITTED.
WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WOW.
MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM
AND TRANSFER THEM TO THE BUILDING STRUCTURE.
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
—_-
MIAMI-DADE COUNTY APPROVED
MULLION & MULLION ANCHORS
SEE SEPARATE NOA
_ EDGE
DIST. j
_----------------�
TORS
FOR SPACING
TYPICAL ANCHORS: SEE ELEV. FOR SPACING
FOR SPACING
1 /4- DIA. TAPCON BY 'TTW' (Fu=125 KSI, Fy=100 KSI)
1/4" DIA. ULTRACON BY 'ELCO' (FU=177 KSI, Fy=155 KSI)
1 /4" DIA. ULTRACON+ BY 'DEWALT' (Fu=164 KSI, Fy=148 KSI)
INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
1-3/8" MIN. PENETRATION INTO WOOD
THRU 1BY BUCKS INTO CONC. OR BLOCKS
1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
1-1/4" MIN. EMBED INTO BLOCKS (JAMBS)
DIRECTLY INTO CONCRETE OR BLOCKS
1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
1-1/4" MIN. EMBED INTO BLOCKS (JAMBS)
414 5MS OR SELF DRILLING SCREW OR SELF DRILLING (FU-74 KSI, Fy-57 KSI)
INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO
METAL STRUCTURES (HEAD/SILL/JAMBS)
(3) THREADS MIN. PENETRATION BEYOND SUBSTRATE
ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN.)
STEEL : 1/8" THK. MIN. (Fy = 36 KSI MIN.)
(STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED)
TYPICAL EDGE DISTANCE
INTO CONCRETE AND MASONRY = 2-1/2" MIN.
INTO WOOD STRUCTURE = 1" MIN.
INTO METAL STRUCTURE = 3/4" MIN.
WOOD AT HEAD, SILL OR JAMBS SG=0.55 MIN.
CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN.
C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN.
ADDED ANCHOR TYPE
- JR - 07/07/20
z
a
a
o
�
•nab
w
no
O
wj
alap
U)
O
(
O
S
j
a
ZO Z
z
W
Z
2
d0 ~
in 0lzLL �
aka
K 0 U d
Z_
VJ
g w zW
'ON
w o > �
0
JMa
LL
CIE dz°
j
=
N U
J
0
`o ?
m ¢
z
to
V
raa45
0
= O W
w
�`
J
J
W
m v_ �<�n
m
¢
F
Z
F-
W
E 52
3 0
z
W
W
m
2 N
z
O
co
LL
V)
....
apl
•osap
saueg
``11�,r1 a rr�ri�
Ny LY'VA1
`. �p •........, 14y
N0. 58705 ,}
7P16T#
NAL 00'
A. LYNN MILLER, P.E
P.F-# 58705
E & FLANGE ADAPTOR FRAME
TORS
DIST.
FLANGE. ADAPTOR FRAME
N
1
O
E7 O
rc
Rai
0
INTALLATION DETAILS SHOWN ON PAGES 4
AND 5 APPLY TO BOTH FLANGE FRAME
AND FLANGE ADAPTOR FRAMES.
o
N]C
00
tq
w
J
rG W N
ar�p
to
a'
0
C
7 #
Z
i O
W
z
} ^ '
O Z
0
,
...'a
(n
L'iTi
K tJ tJ w
Z
aN
:)MGaz
<F Z^
w o > ,-.
U'
IL
=
N
w
0
Z
CD
to
in
Z
to
1ea45
w
CL N Ow
Cl)
J
dN
J
I
Z
p C
�oLL�
Z
w
w
m
o
®
Z
V n M-
c)
LL
co
apt
•asap
sa!+ag
LYIV V
No 58705
�3 7 fG
i FUn� ;2cmol'.
/I711Illrlt�
A LYNN MILLER, P.E.
P.E.# 58705
TYPICAL ANCHORS
SEE ELEV.
IBY FOR SPACING
WOOD BUCK
S IGE':DlST.
i x
id a �• d, . d
A 1 M3 Y JZ E1
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
m
w
ow
YIt
U
m
0
0
3�
0
m3
N
TYPICAL. ANCHORS
EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY
INTO WOOD, CONCRETE OR METAL STRUCTURES
WITHOUT THE NEED OF A WOOD BUCK.
2 3/�
♦
n ♦`♦
2 3/8- MIN.
EQUAL LEG FRAME
EDGE II MIAMI-DARE COUNTY APPROVED
DIST. s I MUWON & MULLION ANCHORS
= II SEE SEPARATE NOA
�EDGE�
TYPICAL ANCHORS \_TYPICAL ANCHORS
SEE ELEV. SEE ELEV.
FOR SPACING MIAMI-DADE COUNTY FOR SPACING
a
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
c
z`
a
a
O
�
•nab
O
0
w m
W rn
aloe
O
ZK z
Z' o_
g
O
z
LU
Z
¢o< ~
v
LL
Q Z
O
VMOJp
LW_
a
S
Z
to j�
Z
oN
DMO
adz°
y Z
S
J
rn
LL
0
C O
(7
f0
VJ
fA
taa45
O(r
C 3= o
W
o z �m
o
6C ¢_`'�
W
W
0 ;�o6a
Un2�
LU
W
\\111111 flit,
N0. 58705 .
- r -
WHEN USED THE MIN. WOOD BUCK — ' �—Zr�
DEPTH SHALL BE 2�b THE USE OF ' 00 S T� t,
F&EE •' DEEPER OR BEVELED WOODBUCKS IS
T. i O HORS PERMITTED. �r /ONAISEE ELEV,
IBY FOR SPACING.BUC A LYNN MILLER, RE
.,•WOOD K
P.E. 58705
TYPICAL ANCHORS
ILLUSTRATIVE DIU. ONLY SEE ELW' FIN FRAME
EXT. OR INT. FINISHES E7 FOR SPACING
NOT BY CGI i
HOUSE WRAP TYPICAL ANCHORS: SEE ELEV. FOR SPACING
NOT BY CGI
#A SMS (Fu=74 K51, Fy=57 KSI)
AZ Et INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
EEI - -- J BACKBED 1-1/4" MIN. PENETRATION INTO WOOD
CAULKING
M2
S5
� M9
a
O I
J
O
a
SWEEP LOCK N Y <
1 OPTIONAL TO
EGRESS LOCK o •„aa
AT SILL w o 0
OWOOD STRUCTURE 1/4' MAX. BUCK HEIGHT 1/4' MAX' Lu N aloe O
B NOT BY CGI GAP GAP z( z U Z
1/2" MIN. 1/2- MIN. o W d
E4 2 O
r m Z LL u1 Q uMo,p
j WWUVo W z_
ut 'JMO
D2 > < z
i = LL
CAULKING c z KBEDW-JU' O
0 0 oS ?
in pp¢ K fn 7aaV5
O W
rmcan Q z
E3 o<LL° o w
ru
{>♦ N Et t z_ W o
S4 1 ® u� N LU Z
Fri LU
T`✓ U)FL
W 1 i HOUSE WRAP aArl —.0 sau.S
E6 NOT BY CGI
i E3 EXTERIORmg
D.L. OPG. :� �`C7• •. ' 1//
14 BACKBED F: '•.�
CAULKING _ No.58705 �
E2
HOUSE WRAP 7
f7
NOT BY CGI
'1 CRIUP = ��^ ' .:CF. \
_ . •'
`s/OR1AL
++'Inittt
E7 TYPICAL ANCHORS A. LYNN MILLER. P.E.
SEE ELEV.
FOR SPACING P.E.# 58705
TTEN
PART 19
QUANTLTY
DESCRIMON
MATE U LL
MANF./SUPPL=/RENABKB
E7
CGI-100
1
FRAME HEAD
6063-T6
-
E2
CGI-101
1
FRAME SILL
6063-T6
-
E3
CGI-102
2
FRAME JAMB
6063-T6
-
E4
CGI-103
1
MEETING RAIL
6063-TS
-
E5
CGI-104
1
LOCK RAIL
6063-T6
-
E6
CGI-105
1
HANDLE RAIL
6063-TS
-
E7
CGI-106
2
SASH RAIL
6063-T6
-
E8
CGI-107
AS READ.
5/16' GLAZING BEAD
6063-T5
-
E9
CGI-108
AS REQD.
0.7D0' GLAZING BEAD
6G63-T5
-
E10
CGI-109
AS REQD.
FRONT FLANGE ADAPTOR
6053-75
-
E11
CGI-110
AS REQD.
NAIL FIN ADAPTOR
6063-75
-
E12
CGI-135
1
FLANGE FRAME HEAD
6063-T6
-
E13
CGI-136
2
FLANGE FRAME JAMB
6063-T6
-
E14
CGI-137
1
FLANGE FRAME SILL
6063-T6
E17
CGI-605
OPTIONAL
SCREEN FRAME
6063-TS
-
M1
CGI-38ZV
AS REQD.
GLAZING BULB VINYL (DUROMETER 75-80 SHORE A)
PVC
-
M2
CGI-111
OPTIONAL
SCREW COVER
PVC
PROTOTYPE OR EQUIV.
M3
CGI-112
AS REQD.
EQUAL LEG COVER/SHIM, 3" LONG AT ANCHOR LOCATIONS
PVC
-
M9
SUPER BOOST
2/ WOW.
SPIRAL BALANCE
-
BSI OR EQUN.
M10
-
2/ WOW.
BLOCK/TACKLE BALANCE
-
BSI OR EQUN.
M11
W23201NG
AS REQD.
PILE WITH CENTER FIN
WOOL
ULTRAFAB OR EQUIV.
M12
CGI-129
1/ WOW.
EGRESS LOCK
ALUM.
SULLIVAN
M13
CGI-131
2/ WOW.
HANDLE RAIL END CAP
NYLON
M&M
M14
E26018WN
-
D BULB-T SLOT
PVC
ULTRAFAB OR EQUIV.
M15
CGI-133
4/ WOW.
SASH GUIDE(SPIRAL BALANCE)
NYLON
M&M
M16
CGI-130
2/ WOW.
SASH TOP GUIDE(SPIRAL BALANCE)
NYLON
M&M
M17
A30730401-32
1/ WOW.
CAM LOCK
ZINC
TRUTH OR EQUIV.
M16 j
CGI-132
2/ WOW.
SASH STOP, 2' LONG
PVC
PROTOTYPE OR EQUIV.
M19
-
2/ LITE
SETTING BLOCK
EPDM
DUROMETER 85±5 SHORE A
M20
CGI-125
2/ WOW.
SASH CAM (B/T BALANCE)
NYLON
M&M
M21
-
2/ WOW.
B/T BALANCE TAKE OUT CUP
-
BSI OR EQUN.
M22
146-6
2/ WOW.
WEEP COVER
NYLON
AMESBURY OR EQUN
M23
CGI-134
-
SILL SPACER
PVC
PROTOTYPE OR EQUIV.
S2
-
2 OR 3/CORNER
# 10 X 1 1/4' LG. PHL PH. SMS. ST/ST. ASSEMBLY SCREW
-
-
S4
-
4/ WOW.
# 8 X 1/2' PH, SMS. ST/ST BALANCE BRACKET SCREW
-
-
S5
-
2 WDW.
# 8 X 1' LG. FH. SMS. ST ST. SPIRAL B. ASSEMBLY
-
-
S6
-
2/ LOCK
# 6 X 1/2' LG. FH. SMS. ® COI-133 & CAM LOCK
-
-
C
w
?On
¢O�J
m Cz LL O
W=W7
aWzv
w�
n`p
aza
L1
z
O
°OW
W
z
QNa
0
zzi=
30�
U to=
1�++111111I/f
No. 58705
71?TE�F
d' • '•F� ORIU�•,..•'•,� .
O E
is�IALi++�`
A LYNN MILLER, RE
P.E.'# 58705
'oN
2.505
.065
1.745 .611
06
2.505
.811
1.245
r-.065
1.550 1.680
�
52
.745 :n,P
1.015
.745 085
TYP.
1.015
.050 I 7.395
--FIN
E72 FLANGE FRAME HEAD
Et FLUSH FRAME HEAD
E11 NAIL ADAPTER
VENT TOP CORNER
1.583
1.429
1.583
Ofi5
TYP•
3.175
1.007
745
O65 2.113
�'
1.368
t-D75
3.67-9
1 42s
Ofi5
TYP.
3.175
c
9
.065
1.000
.500T
T
2.So5
_
O
cr
j rn
Z.
ZZI
ti
O
alap
c
of
a a
.500
1.220
E4"
MEETING RAIL
FRAME TOP CORNER
2505
Eta
1.220
Q
Z
FLANGE FRAME SILL
FLUSH FRAME SILL
❑ o
w
se
.500ii7l
1.3011.043o1.7BB
Z �y"', 0Q
IIO65
.065 065
TYP.
TYR
ui K X:U m KZ
aZ
W o ,-.
'ON
5ma
m
0LOCK
�5
2.440
2.440
1.015
I
a o Z
j
W
1.015
RAIL
�
FRAME BOTTOM CORNER VENT BOTTOM CORNER
� � z
H p c �-
yo 1. ]
ti o
�
z
j
=aays
2.195
.745
2.848
.745
_l
U1
Eta
2.346
O
i'o v�y < S
�'�IC NxMo
3 LL
Q
Z
O
~
W
FLANGE FRAME JAMB
FLUSH FRAME JAMB
1.892
5
1.043
a c
Z � 2 g
N
�
a,
o
.490
.75
0
.050IYP
L1vLOPp'
sa�uas
--I 4
O
L.705
.66
HAND RAIL
OE8
5/16" GLAZING BEAD
Es
O 700" GLAZING BEAD
'•.
No.58705 _ -
1.395
1.449
I -'{II b
"293
1.395
745
.565
1.450
.180
_-
-'� •-'� (/�
�� •. s 1-E F : • [L� �
Cis' -FL ORID%`,. •' \'C,�
.050
A. 5
.060 I i
.675
f-
.550 X511
'� Sj �
I--1.413--I
��r1iAL 111
M3
FLUSH FRAME COVER
M19 SCREW COVER
O SASH RAIL
Eto FLANGE ADAPTOR
A LY
E.#567EP E 05
P.E.