Loading...
HomeMy WebLinkAboutNotice of AcceptanceMIAMI-�E " MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) wwwaniamidade.Qov/building CGI Windows and Doors, Inc. 3780 W 104" Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Sentinel 110" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. SH110-LM-NOA, titled "Series 110 Alum. Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a pennanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-1018.08 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0722.09 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 T9/1/20 Page 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 10-0510. 11) 2. Drawing No W10-03, titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10, with revision D dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed. window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) Manuel Perez, P.E., Product Control Ex " r' NOA No. 20 0722.09 Expiration Date: September: Approval Date: September 10, 2020 E-1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) B. TESTS (CONTINUED) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a series "Sentinel" aluminum single hung window, prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 10-0510.11) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 61n Edition (2017), dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/ 18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. Manuel Perez, P.E1 Product ControA l Ex r NONo. 20 0722.69 ' ;xpiration Date: September , 2 Approval Date: September 10, 2020 E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5" Edition (2014), and of no financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 10-0510.11) 3. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, Supervisor. (Submitted under NOA No. 15- 0512. 10) G. OTHERS 1. Notice of Acceptance No. 15-0512.10, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 08/06/15 and expiring on 09/22/20. If MEIiY�W. I . Manuel '1'erez; P.E. Product Control Ex r NOA No. 2 0722.09 ' Expiration Date: September, , 2 Approval Date: September 10, 020 E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No SII110-LM-NOA, titled "Series 110 Alum Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested to qualify Dowsi1791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08/24/20 and signed and sealed by Idalmis Ortega, RE C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 7tn Edition (2020), dated 07/11/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. w� Manuel erez,,P.E Product Control Exaf e d. NOA No. 2 O( 722.0 Approval Date: September 10, 2021 E-4 CGI Windows and Doors. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® XtraTM (SGXTm) Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6" Edition (2017) and the FBC 7" Edition (2020), dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated July 16, 2020, signed and sealed by Anthony Lynn Miller, P.E. 5. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 17-1018.08, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 12/21/17 and expiring on 09/22/20. Manuel Perez, P. Product Control EE0722. " NOA No. 20Expiration Date: September Approval Date: September 10, 20 E-5 mi AP FLANGE & FLANGE ADAPTOR FRAME SERIES SENTINEL 110 ALUMINUM SINGLE HUNG WIND0� LARGE & SMALL MISSILE (LM & SM) DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. EQUAL LEG FRAME INTINS APPDE FIN FRAME APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WINDOW WITH OTHER CENTER ANCHOR REQUIRED WHEN MIAMI-DADE COUNTY APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN SPACING EXCEEDS 20 9/16" PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) AND 2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). LAMINATED GLASS 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED INSULATING LAM. GLASS PRODUCT LOADS TO THE BUILDING STRUCTURE SMALL MISSILE IMPACT ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF S INSTRUCTIONS. SPECIFIED LARGE MISSILE IMPACT EMBEDMENT TO BASED MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE, ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL REVISED FOR 2020 FBC, ADDED ANCHOR TYPE, BACKBEDDING & REFORMATTED - JR - 07/07/20 N Y Q •nay W UJ °SON O 2 O i z¢ " zo z o_ z } J p m Uma'o o z E! � Woo. Q�ZmP oN c z JM0 rn LL a z 7 S y W J O Z C) y C Z zi OC 3so z e aye m ZO ~ z IL z�= W Q o 0 Vn=M N W apq •asap s ua$ r LY,V jar , a , L,cevsr ••�(�, No.58705 N 1 A7E F CL/� 'S8/0NAL E� A LYNN MILLER, RE P.E.# 58705 EQUAL LLTB.S WINDOWS DESIGN LOAD CAPACITY - PSF FIANCE DIMS. BUCK DIMS, GIA99 TYPE 'A'k'Al' GIA89 TYPE 'B'k'Bl' WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) TNT.(-) 19-1/8' 26-1/2' 37' 49' 53-1/8' 26' 18-1/8' 25-1/2' 36' 48' 52-1/8' 25' 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0. B0.0 85.0 75.0 75.0 50.0 85.0 75.0 75.0 80.0 65.0 19-1/8' 26-1/2' 37' 49' 53-1/8' 38-3/8' 18-1/8' 25-1/2' 36' 48' 52-1/8' 37-3/S' 76.0 75.0 80.0 85.0 75.0 75.0 80.0 B5.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 B5.0 75.0 75.0 80.0 85.0 19-1/8' 26-1/2' 37' 49' 53-1/8' 50-5/8' 18-1/8' 25-1/2' 36' 46 52-1/8' 49-5/8' 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 19-1/8' 26-1/2' 1. 49' 53-1/8' 63' 18-1/0' 25-1/2' 36' 48' 52-1/6' 62' 75.0 75.0 80.0 85.0 75.0 75.0 80.0 65.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 95.0 19-1/8' 26-1/2' 37' 49' 53-1/8' 76' 16-1/6' 25-1/2' 36' 48' 52-1/8' 75' 75.0 75.0 00.0 85.0 75.0 75.0 80.0 B5.0 75.0 78.0 80.0 85.0 75.0 75.0 B0.0 85.0 75.0 75.0 00.0 85.0 19-1/8' 26-1/0 37' 46-1/2' �• 18-1/8' 25-1/2' 36' 45-1/2' w 75.0 75.0 90.0 B5.0 75.0 75.0 80.0 65.0 75.0 75.0 80.0 8.5.0 75.0 75.0 813.0 85.0 WIDTH 0 x EQUAL LITES NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219. UNEQUAL LLTES WINDOWS DESIGN IOAD CAPACITY - PSF FIANCE DU®. BUCK DILLS. KMTOP IIfE GLASS TYPE 'A'YAl' GLASS TYPE 'B'k'Bl' WI01H HEIGHT WM HEIGHT 'A' DIM. -(+) I -(-) EIR.(+) INI.(-) 53-1/8' 76' 52-1/8' 75' 36-1/4' 75.0 75.0 60.0 85.0 49' 79 48' 78' 39-1/4' 75.0 75.0 80.0 85.0 26-1/2' 31' 33' V. 43' 85' 25-1/2- W. 30 36' 42' 84' 70-5/8' 75.0 75.0 80.0 85.0 63-5/8' 75.0 75.0 80.0 85.0 60' 75.0 7&0 90.0 85.0 53-1/2' 75.0 75.0 60.0 85.0 45-1/4' 75.0 75.0 60.0 85.0 UNEQUAL LITES (ORIEL TYPE) Yt' NP. w TYP. BUCK DIMS FLANGE FRAME FLANGE DIMS _I BUCK DIMS G BUCK DIMS FIN FRAME BUCK DIMS FLANGE ADAPTOR FRAME FLANGE DIMS UNEQUAL LITES (ORIEL TYPE) pkA r ILYNN "',, No. 58705 L lEl���� A L>{Ah IAhIlLER, P.E. P.E.# 58705 .075' Saflex CP With PET Core .075" Saflex CP With PET Core By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' .090" Saflex Clear And Color Glass ¢ .090' Saflex Clear And Color Glass gBy 'Eastman Chemical Co.' > g By 'Eastman Chemical Ca:' .090" SentryGlas® .090' SentryGlas9 'Kuraray By 'Kuraray America, Inc.' By Americo, Inc.' 1 8- ANNEALED GLASS / .090" Trosifol PVB By 'Kuraray Ameica, Inc.' 1/8' HEAT STREN'D GLAS .090* Trosifol PVB y 'Kuraray Ameica, Inc.' 1/8- ANNEALED GLASS 1/8- HEAT STREN'D GLASS p. F SILICONE, SILLCQNE: m M1 GE 1200 DOW CORNING 791. 899, 983 & 995 = m M1 GE 1200 DOW CORNING 791, 899, 983 & 995 N � \ / � C., \ a / 0 EB 1 GLASS TYPE 'A' 5/16" OVERALL LAM. GLASS (L.M.I & S.M.I.) .075" Saflex CP With PET Core By 'Eastman Chemical Co.' 1/8- ANNEALED GLASS w .090" Saflex Clear And Color Glass 3 By 'Eastman Chemical Co.' 1/4- AIR SPACE w .090' SentryGlas® By 'Kuraray America, Inc.' 1/8- ANNEALED .090' Trosifol PVB OR TEMPERED- GLASS By 'Kuraray Ameica, Inc.' 1/8" ANNEALED GLASS c SILICONE: a GE 1200 N DOW CORNING 791, /899. 983 & 995 XL EDGE SPACER ST. STEEL BY 'CARDINAL' OR 0 DURASEAL BY 'QUANEX' OR 1 SUPER SPACER BY 'QUANEX' GLASS TYPE 'Al 0.70' OVERALL INSUL LAM. GLASS (L.M.I & S.M.I.) ES 1 GLSS TYPE 'B' 5/16- OVERALL LAM. GLASS (L.M.I & S.M.I.) .075" Saflex CP With PET Core By 'Eastman Chemical Co.' 1 /8' HEAT STREN'D GLASS .090" Saflex Clear And Color Gloss gBy 'Eastman Chemical Co.' 1/4" AIR SPACE .090' SentryGlos® By 'Kuraray America, Inc.' 1 /8' HEAT STREN'D .090' Trosifol PVB OR TEMPERED+' GLASS By 'Kuraray Ameica, Inc.' 1/B" HEAT STREN'D GLASS c SILICONE' z m GE 1200 DOW CORNING 791, N M1 899, 983 & 995 c7 XL EDGE SPACER ST. STEEL BY 'CARDINAL' OR O DURASEAL BY 'QUANEX' a OR SUPER SPACER BY 'QUANEX' 1 'Elf GLASS TYPE 0.70" OVERALL INSUL LAM. GLASS (L.M.I & S.M.I.) • FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LITE (CAP) MUST BE TEMPERED. ADDED BACKBEDDING TYPES - JR - 07/07120 p N Y Q n nab t w ° O o Ma 0 0 Q N r�ry w Z p ¢Qv ZE: O v W=W W Z Q i. °N u Wo>� Z 9M0 = LL Dt 0 _ N Z 0 0 � � y G Z U) 7aa4' o .fi x oW �. �+ o z 6 0 F v ro m a= "�xr+ E3 oQLL° � H o_ 0 Z w rn zi= W U) o 0oL� g Un=M U rp \j111LLIIliff7j ` ONY LYNIV4�f * No.58705 --05TR i A'� `S�ONAL E�.• A &r4m l-LIW, P.E. P.E.N 58705 IN WOOD BUCK l .,d• QA. .e � aa.• O O E4 n I i i F� 0 �i R+ W N � 54 w �I I M9 . 1 EDGE DIST. 1BY W00D BUCK FOR SPACING I £DG R015T.� SWEEP LOCK OPTIONAL TO EGRESS LOCK AT SILL .• • " a TYPICAL. ANCHORS SEE ELEV. FOR SPACING FLANGE & FLANGE ADAPTOR FRAME :AL ANCHORS ELEV. SPACING 2 3/�r� JJJJ����III!! 2 3/����LL WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%". THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WOW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS SEE ELEV. FOR SPACING —_- MIAMI-DADE COUNTY APPROVED MULLION & MULLION ANCHORS SEE SEPARATE NOA _ EDGE DIST. j _----------------� TORS FOR SPACING TYPICAL ANCHORS: SEE ELEV. FOR SPACING FOR SPACING 1 /4- DIA. TAPCON BY 'TTW' (Fu=125 KSI, Fy=100 KSI) 1/4" DIA. ULTRACON BY 'ELCO' (FU=177 KSI, Fy=155 KSI) 1 /4" DIA. ULTRACON+ BY 'DEWALT' (Fu=164 KSI, Fy=148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) 414 5MS OR SELF DRILLING SCREW OR SELF DRILLING (FU-74 KSI, Fy-57 KSI) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN.) STEEL : 1/8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD, SILL OR JAMBS SG=0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. ADDED ANCHOR TYPE - JR - 07/07/20 z a a o � •nab w no O wj alap U) O ( O S j a ZO Z z W Z 2 d0 ~ in 0lzLL � aka K 0 U d Z_ VJ g w zW 'ON w o > � 0 JMa LL CIE dz° j = N U J 0 `o ? m ¢ z to V raa45 0 = O W w �` J J W m v_ �<�n m ¢ F Z F- W E 52 3 0 z W W m 2 N z O co LL V) .... apl •osap saueg ``11�,r1 a rr�ri� Ny LY'VA1 `. �p •........, 14y N0. 58705 ,} 7P16T# NAL 00' A. LYNN MILLER, P.E P.F-# 58705 E & FLANGE ADAPTOR FRAME TORS DIST. FLANGE. ADAPTOR FRAME N 1 O E7 O rc Rai 0 INTALLATION DETAILS SHOWN ON PAGES 4 AND 5 APPLY TO BOTH FLANGE FRAME AND FLANGE ADAPTOR FRAMES. o N]C 00 tq w J rG W N ar�p to a' 0 C 7 # Z i O W z } ^ ' O Z 0 , ...'a (n L'iTi K tJ tJ w Z aN :)MGaz <F Z^ w o > ,-. U' IL = N w 0 Z CD to in Z to 1ea45 w CL N Ow Cl) J dN J I Z p C �oLL� Z w w m o ® Z V n M- c) LL co apt •asap sa!+ag LYIV V No 58705 �3 7 fG i FUn� ;2cmol'. /I711Illrlt� A LYNN MILLER, P.E. P.E.# 58705 TYPICAL ANCHORS SEE ELEV. IBY FOR SPACING WOOD BUCK S IGE':DlST. i x id a �• d, . d A 1 M3 Y JZ E1 SWEEP LOCK OPTIONAL TO EGRESS LOCK AT SILL m w ow YIt U m 0 0 3� 0 m3 N TYPICAL. ANCHORS EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY INTO WOOD, CONCRETE OR METAL STRUCTURES WITHOUT THE NEED OF A WOOD BUCK. 2 3/� ♦ n ♦`♦ 2 3/8- MIN. EQUAL LEG FRAME EDGE II MIAMI-DARE COUNTY APPROVED DIST. s I MUWON & MULLION ANCHORS = II SEE SEPARATE NOA �EDGE� TYPICAL ANCHORS \_TYPICAL ANCHORS SEE ELEV. SEE ELEV. FOR SPACING MIAMI-DADE COUNTY FOR SPACING a TYPICAL ANCHORS SEE ELEV. FOR SPACING c z` a a O � •nab O 0 w m W rn aloe O ZK z Z' o_ g O z LU Z ¢o< ~ v LL Q Z O VMOJp LW_ a S Z to j� Z oN DMO adz° y Z S J rn LL 0 C O (7 f0 VJ fA taa45 O(r C 3= o W o z �m o 6C ¢_`'� W W 0 ;�o6a Un2� LU W \\111111 flit, N0. 58705 . - r - WHEN USED THE MIN. WOOD BUCK — ' �—Zr� DEPTH SHALL BE 2�b THE USE OF ' 00 S T� t, F&EE •' DEEPER OR BEVELED WOODBUCKS IS T. i O HORS PERMITTED. �r /ONAISEE ELEV, IBY FOR SPACING.BUC A LYNN MILLER, RE .,•WOOD K P.E. 58705 TYPICAL ANCHORS ILLUSTRATIVE DIU. ONLY SEE ELW' FIN FRAME EXT. OR INT. FINISHES E7 FOR SPACING NOT BY CGI i HOUSE WRAP TYPICAL ANCHORS: SEE ELEV. FOR SPACING NOT BY CGI #A SMS (Fu=74 K51, Fy=57 KSI) AZ Et INTO 2BY WOOD BUCKS OR WOOD STRUCTURES EEI - -- J BACKBED 1-1/4" MIN. PENETRATION INTO WOOD CAULKING M2 S5 � M9 a O I J O a SWEEP LOCK N Y < 1 OPTIONAL TO EGRESS LOCK o •„aa AT SILL w o 0 OWOOD STRUCTURE 1/4' MAX. BUCK HEIGHT 1/4' MAX' Lu N aloe O B NOT BY CGI GAP GAP z( z U Z 1/2" MIN. 1/2- MIN. o W d E4 2 O r m Z LL u1 Q uMo,p j WWUVo W z_ ut 'JMO D2 > < z i = LL CAULKING c z KBEDW-JU' O 0 0 oS ? in pp¢ K fn 7aaV5 O W rmcan Q z E3 o<LL° o w ru {>♦ N Et t z_ W o S4 1 ® u� N LU Z Fri LU T`✓ U)FL W 1 i HOUSE WRAP aArl —.0 sau.S E6 NOT BY CGI i E3 EXTERIORmg D.L. OPG. :� �`C7• •. ' 1// 14 BACKBED F: '•.� CAULKING _ No.58705 � E2 HOUSE WRAP 7 f7 NOT BY CGI '1 CRIUP = ��^ ' .:CF. \ _ . •' `s/OR1AL ++'Inittt E7 TYPICAL ANCHORS A. LYNN MILLER. P.E. SEE ELEV. FOR SPACING P.E.# 58705 TTEN PART 19 QUANTLTY DESCRIMON MATE U LL MANF./SUPPL=/RENABKB E7 CGI-100 1 FRAME HEAD 6063-T6 - E2 CGI-101 1 FRAME SILL 6063-T6 - E3 CGI-102 2 FRAME JAMB 6063-T6 - E4 CGI-103 1 MEETING RAIL 6063-TS - E5 CGI-104 1 LOCK RAIL 6063-T6 - E6 CGI-105 1 HANDLE RAIL 6063-TS - E7 CGI-106 2 SASH RAIL 6063-T6 - E8 CGI-107 AS READ. 5/16' GLAZING BEAD 6063-T5 - E9 CGI-108 AS REQD. 0.7D0' GLAZING BEAD 6G63-T5 - E10 CGI-109 AS REQD. FRONT FLANGE ADAPTOR 6053-75 - E11 CGI-110 AS REQD. NAIL FIN ADAPTOR 6063-75 - E12 CGI-135 1 FLANGE FRAME HEAD 6063-T6 - E13 CGI-136 2 FLANGE FRAME JAMB 6063-T6 - E14 CGI-137 1 FLANGE FRAME SILL 6063-T6 E17 CGI-605 OPTIONAL SCREEN FRAME 6063-TS - M1 CGI-38ZV AS REQD. GLAZING BULB VINYL (DUROMETER 75-80 SHORE A) PVC - M2 CGI-111 OPTIONAL SCREW COVER PVC PROTOTYPE OR EQUIV. M3 CGI-112 AS REQD. EQUAL LEG COVER/SHIM, 3" LONG AT ANCHOR LOCATIONS PVC - M9 SUPER BOOST 2/ WOW. SPIRAL BALANCE - BSI OR EQUN. M10 - 2/ WOW. BLOCK/TACKLE BALANCE - BSI OR EQUN. M11 W23201NG AS REQD. PILE WITH CENTER FIN WOOL ULTRAFAB OR EQUIV. M12 CGI-129 1/ WOW. EGRESS LOCK ALUM. SULLIVAN M13 CGI-131 2/ WOW. HANDLE RAIL END CAP NYLON M&M M14 E26018WN - D BULB-T SLOT PVC ULTRAFAB OR EQUIV. M15 CGI-133 4/ WOW. SASH GUIDE(SPIRAL BALANCE) NYLON M&M M16 CGI-130 2/ WOW. SASH TOP GUIDE(SPIRAL BALANCE) NYLON M&M M17 A30730401-32 1/ WOW. CAM LOCK ZINC TRUTH OR EQUIV. M16 j CGI-132 2/ WOW. SASH STOP, 2' LONG PVC PROTOTYPE OR EQUIV. M19 - 2/ LITE SETTING BLOCK EPDM DUROMETER 85±5 SHORE A M20 CGI-125 2/ WOW. SASH CAM (B/T BALANCE) NYLON M&M M21 - 2/ WOW. B/T BALANCE TAKE OUT CUP - BSI OR EQUN. M22 146-6 2/ WOW. WEEP COVER NYLON AMESBURY OR EQUN M23 CGI-134 - SILL SPACER PVC PROTOTYPE OR EQUIV. S2 - 2 OR 3/CORNER # 10 X 1 1/4' LG. PHL PH. SMS. ST/ST. ASSEMBLY SCREW - - S4 - 4/ WOW. # 8 X 1/2' PH, SMS. ST/ST BALANCE BRACKET SCREW - - S5 - 2 WDW. # 8 X 1' LG. FH. SMS. ST ST. SPIRAL B. ASSEMBLY - - S6 - 2/ LOCK # 6 X 1/2' LG. FH. SMS. ® COI-133 & CAM LOCK - - C w ?On ¢O�J m Cz LL O W=W7 aWzv w� n`p aza L1 z O °OW W z QNa 0 zzi= 30� U to= 1�++111111I/f No. 58705 71?TE�F d' • '•F� ORIU�•,..•'•,� . O E is�IALi++�` A LYNN MILLER, RE P.E.'# 58705 'oN 2.505 .065 1.745 .611 06 2.505 .811 1.245 r-.065 1.550 1.680 � 52 .745 :n,P 1.015 .745 085 TYP. 1.015 .050 I 7.395 --FIN E72 FLANGE FRAME HEAD Et FLUSH FRAME HEAD E11 NAIL ADAPTER VENT TOP CORNER 1.583 1.429 1.583 Ofi5 TYP• 3.175 1.007 745 O65 2.113 �' 1.368 t-D75 3.67-9 1 42s Ofi5 TYP. 3.175 c 9 .065 1.000 .500T T 2.So5 _ O cr j rn Z. ZZI ti O alap c of a a .500 1.220 E4" MEETING RAIL FRAME TOP CORNER 2505 Eta 1.220 Q Z FLANGE FRAME SILL FLUSH FRAME SILL ❑ o w se .500ii7l 1.3011.043o1.7BB Z �y"', 0Q IIO65 .065 065 TYP. TYR ui K X:U m KZ aZ W o ,-. 'ON 5ma m 0LOCK �5 2.440 2.440 1.015 I a o Z j W 1.015 RAIL � FRAME BOTTOM CORNER VENT BOTTOM CORNER � � z H p c �- yo 1. ] ti o � z j =aays 2.195 .745 2.848 .745 _l U1 Eta 2.346 O i'o v�y < S �'�IC NxMo 3 LL Q Z O ~ W FLANGE FRAME JAMB FLUSH FRAME JAMB 1.892 5 1.043 a c Z � 2 g N � a, o .490 .75 0 .050IYP L1vLOPp' sa�uas --I 4 O L.705 .66 HAND RAIL OE8 5/16" GLAZING BEAD Es O 700" GLAZING BEAD '•. No.58705 _ - 1.395 1.449 I -'{II b "293 1.395 745 .565 1.450 .180 _- -'� •-'� (/� �� •. s 1-E F : • [L� � Cis' -FL ORID%`,. •' \'C,� .050 A. 5 .060 I i .675 f- .550 X511 '� Sj � I--1.413--I ��r1iAL 111 M3 FLUSH FRAME COVER M19 SCREW COVER O SASH RAIL Eto FLANGE ADAPTOR A LY E.#567EP E 05 P.E.