Loading...
HomeMy WebLinkAboutProduct Evaluation Report (2) R W R VV Building Consultants, Inc. B, Consulting and Engineering Services'foi the Building Industry P.O.Box230 Valrico,FL33595 • PLonegl3.659(9197 Florida Board'ofProfessional Enaineers;Registry License No;NO r� 'yg f 11-2-0468.2 i l t .... _. UNry Product i- rl ;rfl� Category Sub Category Manufacturer Product'Name Swinging Therma Tru Corporation Fiber-Classic and Smooth-Star Exterior 118 Industrial Drive Composite Edge Opaque Fiberglass'Single Door w/Sidelites Doors Exterior Door Assemblies Edgerton,OH 43617 Inswing/Outswing Phone 419.998.1740 "'Impact" Scope: This it-a Product Evaluatiort.report:issued by R W Building Consultants;.Inc,and;Lyndon F.Schmidt,P:E_for Therma Tru Corporation based on:.Rule.Chapter No;61G20-3,Method.I R-of.the State of Florida Product Approval;,Department of Business.&Professional Regulation, RW Building Consultants and Lyndon F.:Schmidt,.P.E.do'nofhave norwill acquire.financial interest i4# O @j l>�piufacturing or distributing the product or in any other entity involved in the.approval process of the product named.herein.. '�"J Limitations: 1. This-product has been evaluated and is in compliance.with the 7th EdiEion,(2020)Florida,Building Code:(FBC)structural requirements-excluding the"High Velocity.Hurricane Zone"(HVHZ), 2. Product anchors shall be as:listed an0.pace0.as shownaon;details.Anchor onx bednient to base materiai;s.hall°be beyond wall dressing orstucco. 31 WfSert used;in areasc.requiring Win d.borne:debris pro#eciton.this product complies.with.,FBC;Sections 1609.1.24 R301;2..1:2 and:does,not require,an impact resistant covering.This prodi ict'meets;missile level°"D"and.Includes Wind Zone 4 as defined,in ASTM E1.bWarid FBG Sections 16091 2.2 R301 Z 1':2i1:. 4. For2x'stud framing construction,anchoring,of these units.shall be the same%:as thatthovrn f6r.2K buck masoriry construction,:, 5 Site:,condttions,that deviate from the details of drawing FL<20468.2 require further.'engineering analysis by a licensed engineer or registered' architect. 0 Fiber.-Classic.&Smooth-Star Door=and Sidelite panels require the Use of"J"part'number&and must be stained brpainted within six Months of installation_ 7.See drawing.FL-2046&2,for ize and design pressure limitations. Supporting Documents; 1, Test Report No. Test'Standard Testing Laboratory. Signed bv. TEL 61460214' A8 E1866 05;1,996 05&ASTM,E330 02,.E331=00 Testin Evaluation:Lab,Inc.g VX Wright; TEL 01460145 ASTM El 806-02,1996-02.:&ASTM,E330-02,E33.1-00 Testing Evaluation Lab.,lnc: V.K.Wright TEL014.60131 ASTM E1866=02;1996-02<&,-ASTM E330-02;E331.-- Testing Evaluation Lab:,lnc. V.K.Wright TEL 01461612` ASTM:E'1886-06,1996-09A ASTM E330-02;,E33140 Testing Evaluation Lab.,lnc; V.K.Wright; 2. Miami Dade NOA Materials Testing 19-0305:02 Butacite®'PVBanterlayer(Ku.raray) 17-0712.05 Saflex®PVB'Interlayer(Eastman Chemical,Company) 3. _Drawing No. Prepared by Signed.&Sealed bti No.FL-20468 2 RW Building Consultants,Inc..(#9813} Lyndon F.Schmidt,.P.E. 4 Calculations. Prepared,:by Signed:&Sealed by �n Anchoring RW Budding Consultants;anc,,(#9813). �` ` ;. �;>'�,�.,Lyndon F.Schmidt;P.E. 5 Quality Assurance .Certificate of Participation issued by National Accreditation and Management 4 'i'�? L 34C.9 • � m Institute;ceitifyir g;thatTherrt a Tru Gorporptionis manufacturing products within a� quality assurance;program that cornplies with ISOBEC 17020 and.Guide 53. E ' b a t o P Lyndgn.F.Schmidt;.P E. i , FL PE No.43409 Sheet 1:of 1 4. 711412020 F37_ 75.25'MAX OA.FRAMETHERMA1TRU® WIDTH _,75 4SMAX 37.5'MIX. o ME WIDTH FRAME WIDTH _V r * gill M DOORS - A I W? Z Fiber-Classic. & Smooth Star, 0V > z y o�mr Z .37 rye- 821 •• O S v o rn N COMPOSITE EDGE O \ _ m 7 OPAQUE FIBERGLASS SINGLE DOOR a r 2 0 LL d m d �i LL X w/SIDELITE(S) o V* s INSWING/OUTSWING "IMPACT' GENERAL NOTES o- o c 1. This product has been evaluated and is in compliance with the 7th Edition(2020) m Florida Building Code(FBC)structural requirements excluding the"High Velocity ¢� Hurricane Zone"(HVHZ(. 112.75'MAX O.A.FRAME zs 'ki • WIDTH 0 2. Product anchors shall be as listed and spaced as shown on details.Anchor 37.5'MAX. 37.7Y MAX �m a ¢EX embedment to base material shot be beyond wall dressing or stucco. FRAME WIDTH I FRAME WIDTH � o w 3. When used in areas requiring wind bome debris protection this product complies with < a e FBC Sections 1609.12&R301212 and does not require an impact resistant covering. a a This product meets missile level'7 and includes Wind Zone 4 as defined in ASTM 7 /��7 >;m El996 and FBC Sections 1609.1.2.2&R3012.1.2.1. �t j //� 4. For 2x stud framing construction,anchoring of these units shall be the some as that z kshown for 2x buck masonry construction. Z 0 p o z o^ 0= �oGQo 5. Site condiflons that deviate from the details of this drawing require further O g O o o w n m engineering analysis by a licensed engineer or registered architect. w W p o z, o $ �w iaw X �y=V to 6. Fiber-Classic&Smooth-Star Door&Sidelite panels require the use of"S'part numbers ¢ ^a as e and must be stained or pointed within sic months of installation. a TABLE OF CONTENTS SHEEN DESCRIPTION z c 0 1 Typical Elevations,Design Pressures&General Notes 2 Door Panel Details ^ a 3 Sidelite Panel Details — ^o¢ 4 Elevations ^ ^ a 5 Horizontal&Vertical Cross Sections(2X Buck _— Z F 6 Horizontal I.Vertical Cross Sections(IX Buck) a n —Z ° 2 a Z 7 Horizontal&Vertical Cross Sections(Direct to Masonry DESIGN PRESSURE(PSF) DESIGN PRESSURE(PSF) DATE:08/02/16 z E 8 Vertical Cross Sections(Thresholds) CONFIGURATION INSWING 007SWING SCALE: N.T.S. 9 Buck Anchoring POSITIVE NEGATIVE POSRIVE NEGATIVE 'm 2 10 Frame Anchoring owc.er. JK 11 Hardware Details X0,OX,OX0 +50.0 -50.0 +50.0 -50.0 cNx.BY. LFS e 12 Glaang Details DRAWING NO.: 13 Components FL-20468.2 14 Big of Materials See Sheet 4 for Hardware Specifications 1 or t a aISHEET R:\Clients\Therma Tm PERMANENT\A-Florida Product Approvals\FL-20468 W BDR TT FC SS Impact-Composite\C-Drawings\FBC(2020)\FL-2046B.1-3.dwg,2.2 79.2S'MAX.DOOR PANEL HEIGHT O 1.71" 0 m RI Z Q Z Z O ® ® ® q O m y a ern gr- C)� 0 04 mE= 0 ® 13— IO 10 � n � �•, —� F-— 0 5.5" Q n A IA 79.2S'MAX.DOOR PANEL HEIGHT y N N y n �F Z O, i m <n 13 1 m0ao _ Ou qc, N W O [*=L X Z ® ® O A x Z� 8 m O O 0 I II O no 5.5' Q n �O 79.06"MAX.DOOR PANEL HEIGHT N N n N Lz] ® ® m TR 1.71 O a � O m z .;: 4 0 x N Z x Z ® =1 ® m _ p O y g O m 5.5' Q s N N 2 - A Z pppggg N W rT� 0 O I0 A IA (70 m O Z a to W T 17 0 O ✓] W �r Z n o� A O O 0 C 33 3 0 02� 2 o N A ? C —Z \\ A 00 A 3 no tttttunlp O ..0.89" z' No.43409 July 14,2020 � ? 3 x PRODUCT: 000um.ntn Pnporad 9r: �. g�1e OP .• 7HERMA—TRU Lyndon F. Schmidt �'�•'•.•!tiop{D1••:'•��' m 4 7 14 20 UPDATE TO 7th ED 2020 FBC LFS FIBERGLASS DOOR P.E. No. 43409 �i/t� �\ p o Z 0 3 10 08 18 REV. DOOR PANEL OPTION NOTE MT ///�zO(VAfy, 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: GD BUILDING CONSULTANTS,/�ICL�tlttt` IA N N Z to 1 7 17 17 UPDATE TO sth ED 20T7 FBC 6Y DOOR PANEL DETAILS �P.0. Box 230, Vcirico, FL 33595 rn NO DATE Phan. No.: 813.659.9197 REVISIONS FBPE Registry No. 9813 ®201 6 R.W.BUILD-CUN.ULTANTe INC. t R:\Clients\Therma Tru PERMANENT\A.Florida Product Approvals\FL-20468 WSDR TT FC SS Impact-Composite\C-DraMngs%FBC(2020)\FL-20468.1-3.dwg,32 1T 79.25"MAX.PANEL HEIGHT a o� to o o D- is rn w-+ � n n A >a m 0 z o P W OA toO yL S TrrY��S S �D0 WtJ pD �Z Z M 6 7<QQF 00 n IAll `r n _ 7 O y N 0.59'. v 1� 0.59" A sc �,tlll llllfff No.43408 July 14,2020 I PRODUCT: Doeumente Prepared Syr BTMOF THERMA—TRU Lyndon F. Schmidt ' ��••••.;tZOR1D�;.✓�� IL' No o Z 3 10 08 18 REVUPD. DOOR PANEL OPTION NOTE Mi TE TO 7th EDFIBERGLASS DOOR P.E. No. 43409 iii7�y'/O1YA` %WIX o '' y N 2 11/15/17 RECESSED PANEL N07Ai10N JK PART OR ASSEMBLY: GJ�Q��BUILDING CONSULTANTS,f��1LJ 11tt, Im N to\ 1 7117117 UPDATE 70 6th ED 2017 FBC JK SIDELITE PANEL DETAILS J1•(f�l P•O• Box 230, Valrlco, FL 33595 ;' N rn NO, DATE BY Phone No.: 813.659.9197 REVISIONS FBPE Regletry No. 9813 ®2016 R.W.BUILDING CONSUL—NTG INC. I �►�►►u I I u p,� 3 3 3 4 4 4 3 3 3 4 4 5 6 7 5 6 7 5 6 �yM, 6Q;+0=�n ® El 1313 . IgnUP -i 0 ?Fil o E m z m Z K 2 5 v 2 = E ya �do`a 1 v 5 5 v 5 c �d maa� 5 O 6 ® 22 O m 6 ® 2 � Eoz Lj T X0I.: m 6 1 � 7 s o W0 D 4 D 4 �� W s � 1 2 3 4 5 6 1 g 2 3 4 5 6 ' ti E 8 8 8 8 B 8 8 8 8 B 8 al a V n SEE HARDWARE CHART SEE HARDWARE CHART m E ELEVATION OXO ELEVATION m m i2 XOJfM z K ozo� ry 0 F O N O Q N 3 o zo z W W W _0 ozoo N 0 2 a w¢ HARDWARE-TABLE Z o�^^ a MANUFAG7URER MODEL a o ^Q F KNOB: F51 ��^�� m z SCHLAGE DEADBOLT: B60 a+TF-08 02/16 = a KNOB: SIGNATURE SERIES C W KWIKSET DEADBOLT: SIGNATURE SERIES(980) o scAM BY.. N.T.S. JK m F Fiber-Classic/Smooth-Star Door Panel Options Products approved include ail embossed and recessed panel doors. HOPPE MULTIPOINT:MPDGART CHIC.BY: LFS 3 € Similar opaque panel configurations are allowed. (THERMA-TRU) (3 pt.Manual Tongue) DHAWINO No.: FL-20468.2 m Panels shown are for illustration and are representative only. o SHEET 4 OF 14 N O d y >A� ^ 11 `Iltllilllf/// i 1.15'MIN. Notes: EMB (TYP) 1.Sidefite assembly screws located 6"from each end and 5 more screws z�Q;" m E equally spaced between(7 screws total per side jambl• B E 2.Sidelite assembly screws located 3"from each end&at centerfine _V °�� * Q C B (3 screws along head jamb). �N'_; z' /p'�n a ���n m q J�0.15"C-SINK O L D ��♦ ��� o e o `I OMP (TYP) 0.15'C-SINK ///flf llll�� 9 Z e (TYP) �i E v° o v 1 N °y. SEE NOTE 1 v ° 'E E m =m n D ° 25 v Ea `oa 6 °e maa� N INTERIOR ° B zo v L Z a E u p° C U n n rm O 40 41 42 J atz 24 EXTERIOR vV' m ¢o 50 D e 7 1 H wc�D w w 1-1/4"MIN. 29 �y ) L 40 41 42 1 1-1/4"MIN. In m ` �n EMB. P. EMB (TYP) EXTERIOR INTERIOR o o 00 U g 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTON E $ Shown w/2X Buck $ Shown w/2X BUCK a a Outswin shown Insswin similar (Inswing $ Shown w/2X Buck 9 ( 9 ) Outsw ng shown s m similar) Y Y y Outsving shown(Inswing similar) ���m E LL 1 IF1 D f°i 0.15'C-SINK 0.15"C-SINK_.I F v z K (TYP) (TYP) I E o z o N C) ^ z SEE NOTE 1 25 SEE NOTE 1 v v W z tv tLn n 7 25 (�g�} :Ea I e �i Za W / aC-, a �m f �oo� �Q�U O C W O. U O 02 F N r 1 I ^o�OQ a I as N SEE NOTE 2 Z 50 L 50 50 DATE OB 02/16 23 24 40 41 42 27 25 60 ° 40 41 42 EXTERIOR INTERIOR DWG.BY. JK m' e o 29 ffsHEET LFS 3 E NO.: 5 HORIZONTAL CROSS SECTION 4 VERTICAL CROSS SECTION outsw n shown Inswing s milar 6 HORIZOMAL CROSS SECTION 20468.2 5 g l Outswin shown llnswing similar 5 Shown w/2X Buck °a 5 9 Outswng shown(Inswing similar) S OF 14 u d R:\Clients\Therrna Tru PERMANENT\A-Florida Product Approvals\FL-20468 WBDR T7 FC SS Impact-Composite\C-Drawings\FBC(2020)\FL-20468.1-3.dwg,62 m NQID No CL I'D q. a� 6ama oXa �s Ems^ 0 A a3' a3 o o cob A H 3 0 CL to o. v 3 n g ' O Z 29 N 0 O a a N N m N �0 7o=O m£Q pX� n n Q �.n 0 3 a o ° a v < m m �+ m M a s+. M O uNi Y D . o v O•W A O�T 0 X n o p ? 3 Z Z 2 Z r�r ,p >o 0 n 1-1/4"MIN. EMB.(TYP.) 1-1/4"MIN. EMB.(TYP.) BID �. ,., No.43409 _ July 14,2020 gg a PRODUCT. Document.Pmpured By: BBQgpP rr- F F. D THERMA—TRU Lyndon F. Schmidt �ZpFpDR ' I A °1 ou 4 VDATE UPDATE TO 7th ED 2020 FBC LFS FIBERGLASS DOOR P.E. No. 43409 /o$ Z\ 3 REV. DOOR PANEL OPTION NOTE MT h!YONALj1-' .1 2 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: GD BUILDINO CONSULTANTS, ��ILJ. to i UPDATE TO 6th ED 2017 FBC JK p,0. Box 230, Valrico, FL 33595 rn NO BY HORIZONTAL & VERTICAL phone No.: 813.859.s197 REVISIONS CROSS SECTIONS (1X BUCK) FHPE Registry No. 9813 ®2016 R.W.BUILD—CONS—NTD INC. L 1 PACIlents\Therma Tru PERMANENT\A-Florida Product Approvals\FL-20468 WBDR TT FC SS Impact-Composite\C-Drawings\FBC(2020)\FL-20468.1-3.dwg,72 N �Z rn d1 til 0 N 0 N N f m N O N O N o Qa� CLm:km `0'a�mo g 3 S�S Q O V n0 n .P w&a 1� n m 1.5' 00p V W 2 N 0 3 4" MAX m v m �00= Z v 0 � c0 0 N m o. •o N 1-1/4°MIN. io Q MIN. y,3'ao m EMB.(TYP.) 7A P O QH 0 j7 0 " o _aZ N z oQ N a 0 T O y 1 m cr J-L z m a N V N n M n O `o PC o n EMB.(TYP.' a goy eo Ia a S' a o :; • , 1 MIN. • A z1*1 1.5' c MAX. `�tts n u 1T IT,� ��.``F•SCNIy�� G No.43409 July 14,2020 '^ Q PRODUCT: 13—in. Propmod Sr. +� OIXTEOF iHERMA—TRU Lyndon F. Schmidt �j�•••20MEIN." \ ` I R In 4 7114120 UPDATE TO 7th ED 2020 F13C LFS FIBERGLASS DOOR P.E. No. 43409 I� No o Z o 3 10/08 18 REV. DOOR PANEL OP77ON NOTE 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: GJ� BUILDING CONSULTANTS, IIV� ~ Jl 1 7 17 17 UPDATE TO 6th ED 2017 FBC JK P.O. Box 230.Valrico, FL 33595 HORIZONTAL & VERTICAL { N ° NO DATE BY SECTIONS (DIRECT 70 MASONRY) Phone No.: 813.659.9197 REVISIONS FSPE Registry No. 9813 402G16 R.W.BUILDING CGNauLTnrrrs INC. `IIIIIIIII!!!! Notes: 1.Sill Item#'s 17,18,32,34.35,36,37,38&39 are attached to jambs w/(3)#8 X 2-1/2'pfh screws at each end. SiOltem#'s 16&33 are attached tojambs w/(2)#8 X 2-1/2°pfh screws at each end. _ v+ Sig Item#15Is attached to jambs util'mng(2)#10 X 2'pph SMS at each end. Ze 2 Sidelite assembly screws located 3'from each end&at centerline(3 screws along sill). �S z �'0 emn INTERIOR EXTERIOR INTERIOR EXTERIORpi 1 '>'Z z d; ro EXTERIOR INTERIOR o 9 ao a 40 41 42 m 1 0 0 w¢Em zm 42 ro n a 9°sa 7 16 17 18 .9 a o 38 39 32 33 34 35 36 37 E o z 4 SEE NOTE 1 SEE NOTE I -wa, SEE NOTE 1 E E tv E 8 N � o= W(0 w F-fn a D0 >� z a 1 VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION �1 VERTICAL CROSS SECTION w a a 8 76 $ Inswing sillw 8 Inswing Sig 8 Outsw ng Sid E INTERIOR EXTERIOR T i T ozon o SEE NOTE 2 25 50 EXTERIOR INTERIOR N G¢o EXTERIOR INTERIOR a m z 40 S 77 75 32 33 34 35 36 37 38 39 SEE NOTE 2 25 50 16 17 18 W t 0)41 42 z:5 aam 10 0000 W 76 o w a 15 E aowa a E SEE NOTE 2 0 ^n m 21 z.;. — p N.T.S. cwc.ar: LFS 3 DRAWING NO.: € 4 VERTICAL CROSS SECTION m 5 VERTICAL CROSS SECTION 6 VERTICAL CROSS SECTION g PubllcAccessSill $ Inswing Sig 8 Outswing Sill FL-20468.2 N SHEEP $ OF 14 G I FINClientATherma Tru PERMANENTtA-Florida Product Apprm als\FL-Z0468 WBDR TT FC SS Impact-Composite\C-Drawings\FBC(2D20)\FL-Z0468.1-3.l 92 Z :._Z -fit ✓/�m 2 �0 v k O ______________ I?'MAX. 4,pp.) I►— ' O.C.(TYP.) k to C n n z � O z �I o. 14 0 I III --I Fes-4"PYR) 19-MAX. �� 4-(TYP.) ```ttt1111IIN/�/�' O.C.(TYP.) �Vf;v��4• i No.43409 July 14,2020 $ $ PRODUCT: Boeumonta Pn,ll By: �� 87117E _ THERMA—TRU Lyndon F. Schmidt i�•• .AtoRiDp: \ c�i t m a 7 14 20 UPDATE ro 7th ED 2020 FBC LFS FIBERGLASS DOOR P.E. No. 43409 I`D NO$ Z\ 3 10 08/18 REV. DOOR PANEL OPTION NOTE MT gill�r NA.1�;` o m'' ` y N 2 11 15 17 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: GJ�Q� BUILDING CONSULTANIS,IIIVL�Iitt` Im x In 1 7 17 17 UPDATE TO 6th ED 2017 FBC JK BUCK ANCHORING Jl��/�l P.O. Box 230.Valrico, FL 33595 1 { N rn NO DATE BY Phone No.: 813.659.9197 REVISIONS FOP. R.gjI No- 9813 ®2016 R.W.BUILDING CONSULTANTS INC. l k\ClienU\Therma Tru PERMANENT\A-Florida Product Approvals\FL-20468 WBDR TT FC SS Impact-Composite\C-Drawings\FBC(2020ffL-20468.1-3.dwg,102 O A Q 0 a z 0� <O zz- �_ �0 O I I I I o r... r �pe T m X O I I 14'MAX. �� 6"ITYP.) O.C.(TYP.) Z o to m Y� n = o 0 Z �_ �0 G) =o v 1 I I I I= I � � r H O O 0 0 O 3 Y I I T an 0 14'MAX. D O.C.(TYP.) 6"IT(P.I =c HN v,.•�cfeF .T No.43409 July 14,2020 TS PRODUCT: D-umeMe Pmpamd ay: Fi 7NERMA-TRU Lyndon F. Schmidt ��� AT;pgyp►.,r'6�` c 4 7 14 20 UPDATE TO 7th EO 2020 FBC LFS FlBERGLASS DOOR P.E. No. 43409 'i & � p o Z o 3 10 08 18 REV. DOOR PANEL OPTION NOTE -VT— /If tJ 2 it 15/17 RECESSED PANEL N07AT10N JK PART OR ASSEMBLY: GD BUILDING CONSULTANTS, IN�fFT, I00 A 0\ 1 7 17 17 UPDATE 70 6fh ED 2017 FBC JK rJL P.O. Box 230, Vnlrlco, FL 33595 j iv rn NO DATE BY FRAME ANCHORING Phone No.: 813.659.9197 REVISIONS FSPE Registry No. 9813 ®201fi R.W.9ulLoiNe CCNCU�TgNT91Nc. R:\Clients%Therma Tru PERMANENTtA-Florida Product Approvals\FL-20468 W BDR TT FC SS Impact-Composite%C-Drawings\FBC R020)\FL-20468.1.3.dwg,11.2 RO 117 n rn w w S �b 0 0 m s• m O ❑ •O .'O O lam• y b b 03 a m IM p•u O o= s n a DA 03 or m 5.S' 0 44.88"(±1.5') N A !V •o �x S = Z T m M n�n a to29.25'(TYP.) rl 1.2S'FROM TOP BOOK DOOR OF JAMB o X 29.75"(TYP.) 11.125'FROM TOP ri Ul/HYBRID DOOR OFJAMB -c O AM �V"1 aos �oo 3� I o 03 n �25.3T' 30.31"------ I C �+ 45.2S'(±1.61 r., Z y 0 S � O n = a 7C c oa c c m o 9� o No.43409 _ July 14,2020 PRODUCT: Documente Pmpamd By: gryL�OF THERMA—TRU Lyndon F. Sehmldt ����\'•.,FIORiDP,:' � n ,°1, $ m 4 7/14 20 UPDATE TO 7th ED 2020 FBC LFS FIBERGLASS DOOR P.E. No. 43409 ��� \\\ o Z 3 10 08/18 REV. DOOR PANEL OPTION NOTE Mr /111fA ALtt�\.\ o {+ " ` y N 2 11115117 RECESSED PANEL NOTATION JK PART OR ASSEMBLY: G�C/�{/BUILDING CONSULTANTS,�I�1C� to 1 7 17 17 UPDATE TO 6th ED 2017 FBC JK HARDWARE DERAILS J1•(I(/ P•D. Box 230, Valrico, FL 33595 I{' N rn NO DATE BY Phone No.: 113.658.1117 REVISIONS FBPE Re Ietry No. 9813 2016 R.W.BUILOIND C.N.ULTANTB INa. R:\Clients\Therma Tru PERMANENT\A-Florida Product Approvals\FL-20468 WBDR TT FC SS Impact-Composite\C-Drawings\FBC(2020)\FL-20468.1-3.dwg.122 r„ v o �A� N (n 2 9 m a � o I� 3.>s _ � ow to —�o3 �3 3 F3 o D � 00a m _ m > > ^� D 5 v> n z o Z Imo-63.23'D.L.O.HEIGHT O mm7 z m Z � 3 tom-- o P m �o n (TVP.) _ I z'MAx.O.C. X (TYP.) .a .a s D rn < 0 a z j G) to z o y � rn D n G) N Z M _O v 0 O o z o N � Z m Z z v..•No. •.r _ July 14,2020 = g PRODUCT: Documents PreparW By. " 8'►A7E •• r�1— Fi THERMA—TRU Lyndon F. Schmidt ��,�•• AOFON..•6 I m 4 7 74 20 UPDATE TO 7th ED 2020 FBC kJK FIBERGLASS DOOR P.E. No. 43409 :; Iry No o Z 0 3 10 08 18 REV. DOOR PANEL OPTION NOTE ��NA►. r r y 2 i 1 15 17 RECESSED PANEL NOTATION PART OR ASSEMBLY: L]? BUILDINO CONSULTANTS,1 7 17 17 UPDATE TO 6th ED 20I7 FBC Jl.'1/I/P.O.NO DATE GLAZING DETAILS YYYYYY Phone No.: 813.859.9197 REVISIONS FBPE Registry No. 9813 (D 201 6 R.W.B.".—CONHIILT—INC. . I 7.59 ��•� z (sn dwm zoo INSWING THRESHOLD 37 INSWING THRESHOLD ^23W0� B `� o = 82 Inswing Basic Fixed 7-1/2'S01 ( 7 E E a i m z rc Inswing Basic Composite Adjustable 5117-1/T \J g t o as Na 96oa. I 4.56" 4.56" S.B3" ? g u Li En �NSWING THRESHOLD *INSWING THRESHOLD OUlSWING THRESHOLD �o m Inswing Basic Faed SN "'� Iruwing Composite Adjustable Sll 6 Composite SBI i Z 5.75' r w o o 5.77' 0 4.56" nu,E. a O u O 4 K 4 Ep a a o L_ .':.. .. ._.. _ Rtmr--� ..;. *NSWUIG THRESHOLD s :Y<ct.... >>m E Inswing Moderate Climate Sig 13/8" INSWING THRESHOLD LL 39 Inswing Basic ComPosfle Adjustable Sig C f sNe aRESHOLD U z Sig z U - ozR oGQo 3 5,75' 6.(r5.75" N p Z z (n ¢N o W W c o C5 W Wr N m e N $'az _ 0 C n d¢a m } o0Wo o v w a INSWING THRESHOLD I OUiSWING THRESHOLD a w a d 35 tnswing Moderate Climate 511 PUBUC ACCESS THRESHOLD 8 Composte/Aluminum Sll o o c r� (Therrnal8re.kJ z 5.75' a I 19 a o N DATE 08102 16 c f � a�y:3:.;.,+•;:..y..o-i.''::�k::r;'^=a;a;.,:�:,� to o'• a sML- N.T.S. � o o Dwc.en JK a INSWING THRESHOLD I I j m ��-1.77'—�I f 1.92 _ 206" 1-- o 0 3 E Inswing Basic Foced 5-3/4"Sill DRAWING e*: LFS o SWEEP SWEEP SWEEP o SIDE[HESPACER SIDEU%VkER SIDELIIESPACER owwnvcNo.: 8 9 �0 �$ Inswing o 76 Oufswtng �� Inswing FL-20468.2 N Moderate Climate Threshold sxeer 13 of 14 B v `�quuurrrl� BILL OF MATERIALS BILL OF MATERIALS ITEM# DESCRIPTION MATERIAL ITEM# DESCRIPTION MATERIAL _ ��� n 33 ro A 1 X BUCK(SG>=0.42) WOOD 25 #8 x 2-1/2"PFH WOOD SCREW STEEL ye Q'"'^ B 2X BUCK(SG>=0.42) WOOD 26 #8 x 5/8"PFH WOOD SCREW STEEL omm C 1/4"MAX.SHIM SPACE 27 LATCH STRIKE PLATE STEEL 'I '....... kq.` D 1/4"X 2-3/4"PFH ELCO'OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE STEEL �'��� P ���` >>°z E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE 28A DEADBOLT SUB STRIKE PLATE STEEL prrr ►►►► o°n m z 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 29 4"X 4"HINGE STEEL o °N o F #10 X 2"PFH WOOD SCREW STEEL 30 LATCH 8.DEADBOLT STRIKE PLATE(TONGUE SYSTEM) ALUM/COMP E m z m Ix G 3/16"X 3-1/4"ITW CONCRETE SCREW STEEL 31 MULTIPOINT STRIKE PLATE(TONGUE SYSTEM) ALUM/COMP \v' a 9 d 5 m I 1/4"X 1-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 32 INSWING THRESHOLD ALUM/COMP 4 . `a � J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP E a? L #10 X 2-1/2"PFH WOOD SCREW(1.15"MIN.EMBEDMENT) STEEL 34 INSWING THRESHOLD ALUM/COMP2. rW o �a M 3/16"X 2-1/4"ITW CONCRETE SCREW STEEL 35 INSWING THRESHOLD ALUM/COMP g N 3/16"X 2-3/4"PFH ITW CONCRETE SCREW STEEL 36 INSWING THRESHOLD ALUM/COMP 1 JAMB(FINGER JOINT PINE) WOOD 37 INSWING THRESHOLD ALUM/COMP C 6 WEATHERSTRIP(MEDIUM REACH) FOAM 38 INSWING THRESHOLD ALUM/COMP o 7 WEATHERSTRIP(LONG REACH) FOAM 39 INSWING THRESHOLD ALUM/COMP �N 8 SWEEP VINYL 40 DOOR PANEL(BOOK) ,C. 9 SWEEP(USE w/MODERATE CLIMATE THRESHOLD) VINYL 41 DOOR PANEL(HYBRID) w 0 o 10 SWEEP(USE w/PUBLIC ACCESS THRESHOLD) VINYL 42 DOOR PANEL(U1) _ m 15 PUBLIC ACCESS THRESHOLD ALUM 50 SIDELITE m E 16 OUTSWING THRESHOLD ALUM/COMP 75 SIDELITE SPACER(INSWING) PVC &I 17 OUTSWING THRESHOLD ALUM/COMP 76 SIDELITE SPACER(OUTSWING) PVC 18 OUTSWING THRESHOLD ALUM/COMP 77 SIDELITE SPACER(INSWING)-MODERATE CLIMATE SILL PVC E 22 #8 x 3/4"PFH WOOD SCREW STEEL 23 #10 x 3/4"PFH WOOD SCREW STEEL i= 24 #10 x 1"PFH WOOD SCREW STEEL NO 8 O z C1 N a a N a z En CONCRETEANCHOR NOTES: w w o S 1.Concrete anchor locations at the comers may be adjusted to maintain the min. r edge distance to mortar joints. ^a a m in 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to 0 0 0 2 maintain the min.edge distance to mortar joints,additional concrete anchors �2 o N F a may be required to ensure the'MAX.ON CENTER"dimension are not exceeded. o o 3.Concrete anchor table: 0 0 o MIN CLEARANCE: 'MIN CLEARANCE N ANCHOR ANCHOR MIN ^ 70 MASONRY TO ADJACENT a a TYPE 51Ze EMBEDMENT EDGE —ITW TAPCON® 1/4" 1-1/4" 2" 4" a n N—Z o z ELCO ® DATE:08102116 i a ULiRACON 1/4" 1-1/4" 1" 4" scram• N.T.S. I ITW ® 3/16" 1.1/4" AS SHOWN 1-1/2" Dwc.E': a TAPCON CHK.BY: LFS 3 E WOOD SCREW INSTALLATION NOTES: DRAWING Ho.: 1.Maintain a minimum 5/8"edge distance,1"end distance,&I"o.c.spacing of m y wood screws to prevent the splitting of wood. FL-20468.2 N 0 SHEa 14 OF 14 g G d i� s`