HomeMy WebLinkAbout11652 Orange Ave Compaction testSoil Nuclear Gauge
Client:
Project:
Gnp'
Report Date: 4/23/2021
Environmental Land Development, Inc.
18-9980.00
P
Test Method: ASTM D 6938
201 Campbell Road
Environmental Land Development 2018-2019
Port St. Lucie
Fort Pierce, FL 34945
Various Locations
FBPE CA # 4930
FL
607 NW Commodity Cove
Pon St. Lucie, FL M986
Phone: 772-924-35751 Fax: 772-924-3580
Test Results
Maximum
In Place
In Place
Optimum
Dry
In Place
Dry
Wet
Probe
Min/Max
Retest
Soil
Moisture
Density (pcf)
Moisture
Density
Density
Depth
Percent
Comp.
Test #
Of
Test Date
Proctor ID
Method
Classification
( % )
( % )
(pcf)
(pcf)
(in)
Compaction
( % )
Remark
62
4/12/21
9184 - LBR
N/A
10.9
114.6
10.8
112.0
124.1
12
98
951105
Pass
63
4112/21
9184 - LBR
N/A
10.9
114.6
12.3
113.4
127A
12
99
95 / 105
Pass
64
4/12/21
9184 - LBR
N/A
10.9
114.6
11.6
112.0
125.0
12
98
95 / 105
Pass
Test Information
Gauge
Test #
Test Location
Elevation
Reference
Make I Model / SN I Calibrated
Field Technician
62
Below Slab Grade: 11652 Orange Avenue, Foundation Pad, E Section
0-1
Troxler / 3430/34641 / 34641 /
Smith, Johnnie
9/30/2020
63
Below Slab Grade: 11652 Orange Avenue, Foundation Pad, W Section
0-1
Troxler / 3430/34641 / 34641 /
Smith, Johnnie
913012020
64
Below Slab Grade: 11652 Orange Avenue, Foundation Pad, Center
0-1
Troxler / 3430/34641 / 34641 /
Smith, Johnnie
9/30/2020
Remarks
Comments
Pass: Tests results comply with specifications
Tests are 'Direct Transmission' (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
62, 63, 64: 1-2, 2-3, 3-4, 4-5' HCP=50+, > 95 % Compaction, PASS.
HCP tests are empirically correlated to the relative density of the soil.
PSpO ... ' /
0�..'�LIGENSF •'•ti�
22 84 6
�O * _
Dominic Montano ,E.
m T�Tfq�Feerlt j�AFi
�f1
ONAL / tt\\\\
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1