HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2..300 Virginia Avenue, Fort Plerce', FL 34982— (772) 462-1553
Certification for Design Load Compliance
Project Name: Century Complete -1650
Project Address: 0 Belleair Dr, Fort Pierce 34951
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:•
• This certification must be completed, signed, and sealed by the design professional of record.
41 Submit (2y copies for residential,•(3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any, non-residential structure.
* Note:. Form not required for interior renovations provided that no exterior structural elements are affected and
certain. minor building permits at the discretion of the local,building official. Contact; the # above for questions.
DESIGN -PARAMETERS AND ASSUMPTIONS USED: (complete all that apply).
1. DESIGN CODE: Florida 202Q _ Code Sixth Edition with 20 NSA Supplements using.ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed. Open
3. Risk Category: I X II III lV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.6 ft
5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: NSA ft
6.. Components &•Cladding Design Pressures Used: (PSF, based, on 10sgft @ 15`MRH, clearly.label on all plan openings):
Zone 1:.+19:3,-30.6 Zone 2: +19:3,-53.3 Zone 3: +1.9.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,-44.8 Garage: +31.7/-38,6
7. Design Loads:, Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony:, NSA PSF
Dock: N/A. PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA .. PSF Railings: 50, PSF
8. Were Shear Walls Considered' For Structure? Y Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 1500 PSF Soil Test Reports' Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, -to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
Co rrity:1 also certify that t structural elements depicted on these plans provide adequate resistance to the design-
0
DEB
2021 fo'r ,��It �, , o James G. Frilin.�� 9
Print Name Cert # & Co. Cert Auth.
No 77824 PE #77824 COA #27228
•� c` ? Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002
atu a eal: /v, .
go
.,
����,�•. P Y Company Name & Address
���I11114►�� �