HomeMy WebLinkAboutAPPROVED 07-2020 Radco approval letter for steps received 6-8-2020. (1)RE: Review ATI test report on fiberglass coated plywood steps for compliance with the most recent code versions Dear Mr. Johnson: We have received the test report you submitted from Architectural Testing (ATI), York, PA. The details are as follows: Report number: 01-37911.04, dated 11/7/03 Title: Step Performance Test Report Products covered: 4-Tread, Dura-Grip II, Step Unit [A five riser, four tread step fabricated with pressure treated lumber and fiberglass]. At your request, we have evaluated the test report against the building codes outlined below. CODE 2015 International Building Code (IBC) Stairway Dimension Requirement Tested Value (2) Compliance Width (1) 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass CODE 2015 International Residential Code (IRC) Stairway Dimension Requirement Tested Value (2) Compliance Width 3611minimum 38" Pass Riser Height 7-3/4" maximum 7" Pass Tread Depth 10" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass Mr. Marty Johnson Style Crest Inc. March 235 2018 Page 2 CODE 2017 Florida Building Code (FBC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass Notes: (1) 44" minimum or 36" if serving an occupant load less than 50. (2) The tested values have been taken from the referenced ATI test report, RADCO has not independently verified any of the actual dimensions, and is not responsible for the accuracy of these dimensions. CONCLUSION: There have either been no changes in the dimensional requirements in the IBC, IRC and the FBC or, as in the case of the Tread Leading Edge Radius, the requirements have been altered minimally, when compared to the requirements listed in the referenced ATI test report number 01-37911.04, dated 11/7/03. The product is therefore in compliance with the dimensional requirements of the editions of the IBC, IRC and the FBC referenced above for the four (4) dimensions shown in the tables. st that this proposal has been responsive to your objectives. Please do not hesitate to call if you have any questions. As always, we look forward to working with Style Crest and to starting this program in the near future. This proposal is valid for 90 days. Sincerely, RADCO Fernando Ardila, Director Testing Laboratories &Materials Evaluation R:\Test Projects\Stylecrest or RMC\C4160A\style crest cotle verifcafion5.wptl