HomeMy WebLinkAboutAPPROVED 37067-ROOFING INFO SHEETST. LUCIE WORKS
Master Permit No.
Section A (General Information).
Process No.
Contractors Name:
Total Home Roofing
License #
CC13330489
Cf7j,
Job Address
S � Ie,.. �I
I
/ ( I J ,
ROOF CATEGORY
YW Slope ❑ Mechanically Fastened Tile ❑ I}rlortar/Adhesive Set Tiles
a4whaltic Shingles ❑ Metal Panel/Shingles '`Mood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance X Reroofing ❑ Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF)�
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
5/19/2021
11174_11798_l.jpg(800x800)
httpsalwww.paslc.orgllmageSketches/sketch/ll/11174_11798_1.jpg 1l1
ST. LUC E WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: Certainteed
Product Approval No.: FL2533-R24
Design Wind Pressures, From RAS 128 or Calculations:
Zone 1': -34.6 Zone 1:"6O 3Zone 2: Zone 3 1 4
Max. Design Pressure, from the specific product approval
system: -127.5
Deck:
Type: Wood
Gauge Thickness: 1 /8„
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s): Fllntl2c;fir _
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Flintlastic --
Top Ply Fastener/Bonding Material:
t
SA
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows
®
woo
Zone 1:—"
oc @ Lap, # Rows
®
"o '
Zone 2:_.._."
oc @ Lap, # Rows
@
40
Zone 3:_..."
oc @ Lap, # Rows
®
° oc
Number of Fasteners Per Insulation Board:
Zone 1':
Zone 1: Zone 2:
Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
Flintlastic
Flintlastic
Parapet
Height
FT.
15'
1 Mean
Roof
Drip Edge: 3" X 3" Galy Alum Height
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: Owens Corning
Notice of Acceptance Number:
FL10674-R1
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:-74 -Zone 2e:' Zone 2n'108one 2r: bone 3e: 108one 3r:-128
Deck Type: Wood
Type Underlayment:
Roof Slop
12 Insulation: N/A
Fire Barrier: N/A
RidgeVentlatilon? Fastener Type & Spacing: 1 1/4" Ring Shank Nails
Adhesive Type: N/A
Type Cap Sheet: N/A
Mean Roof Height: y�_ Roof Covering: LAsphalt Shingles
Type & Size Drip 3" X 3" Galy Alum
Edge: