Loading...
HomeMy WebLinkAboutAPPROVED 37067-ROOFING INFO SHEETST. LUCIE WORKS Master Permit No. Section A (General Information). Process No. Contractors Name: Total Home Roofing License # CC13330489 Cf7j, Job Address S � Ie,.. �I I / ( I J , ROOF CATEGORY YW Slope ❑ Mechanically Fastened Tile ❑ I}rlortar/Adhesive Set Tiles a4whaltic Shingles ❑ Metal Panel/Shingles '`Mood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance X Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF)� Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 5/19/2021 11174_11798_l.jpg(800x800) httpsalwww.paslc.orgllmageSketches/sketch/ll/11174_11798_1.jpg 1l1 ST. LUC E WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Certainteed Product Approval No.: FL2533-R24 Design Wind Pressures, From RAS 128 or Calculations: Zone 1': -34.6 Zone 1:"6O 3Zone 2: Zone 3 1 4 Max. Design Pressure, from the specific product approval system: -127.5 Deck: Type: Wood Gauge Thickness: 1 /8„ Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Fllntl2c;fir _ Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Flintlastic -- Top Ply Fastener/Bonding Material: t SA Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows ® woo Zone 1:—" oc @ Lap, # Rows ® "o ' Zone 2:_.._." oc @ Lap, # Rows @ 40 Zone 3:_..." oc @ Lap, # Rows ® ° oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Flintlastic Flintlastic Parapet Height FT. 15' 1 Mean Roof Drip Edge: 3" X 3" Galy Alum Height ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Owens Corning Notice of Acceptance Number: FL10674-R1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-74 -Zone 2e:' Zone 2n'108one 2r: bone 3e: 108one 3r:-128 Deck Type: Wood Type Underlayment: Roof Slop 12 Insulation: N/A Fire Barrier: N/A RidgeVentlatilon? Fastener Type & Spacing: 1 1/4" Ring Shank Nails Adhesive Type: N/A Type Cap Sheet: N/A Mean Roof Height: y�_ Roof Covering: LAsphalt Shingles Type & Size Drip 3" X 3" Galy Alum Edge: