HomeMy WebLinkAboutdoc02426220210524113255Building Dept.
Project Name
ddress
antractor
Address
SAINT LUCIE COUNTY FIRE DISTRICT
PLAN REVIEW FORM
5160 N.W. Milner Drive
Port Saint Lucie, FL 34983
Telephone: 772-621-3322
Fax: 772-621-36C4
Web Address: www.slcfd.com
`SI-Cr—------_ —_-_ FMOPermit#
Mahi Mahi Bldg ----- BLDG Permit#
—J
I4802 Ocean Palms Drive Unit 1-12 —_ —_ _ _ — City �Ft Pierce
LL I
Cardinal Southern Equities -- ^
FP . Box 643328 -- 9 City i Vero Beach
B-21-181
11908-0215
i
State FL Zip 132964 Telephone (954) 410-3030
Architect/Engineer FrankC Snedakerlr — I Telephone (954) 561-4455
Occupancy Type IApariment(Condo) i Construction Type dill`; Square Feet 32,464
111111 i—_ _
Occupant Load I — Number of Stories 14 Access Box i Required Access Key Switch
�� ` Ti �---_----'.^—� FFP Permit
—�
FS Permit Required i FA Permit e RclUil_d
General Notes
1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be .pdf only.
2. All revisions, including the electronic copy must be received prior to permitting.
3. The Fire Marshal requires 24 hour notice on all inspections.
4. A Radio coverage Pre -Survey Signal Strength inspection is required before any final inspection is scheduled.
S. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
6. Failed inspections require payment of fee prior to rescheduling of further inspections.
7. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans.
8. Fire alarm panels shall be located indoors within air conditioned space.
9. Plans and construction are subject to corrections in the field to maintain code .:ompliarce.
10. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cf=n design capacity.
11. The Installation or Alteration of Fire Sprinklers, Fire A;arms, and Fixed Fire Protection Systems require a separate review and permit.
THE CURRENTLY ADOPTED VERSION OF THE FLORIDA FIRE PREVENTION CODE IS ENFORCED.
BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY
WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING
A CERTIFICATE OF OCCUPANCY.
See Gene,. -a; Notes Alcove and Required Revisions Below
1. A separate revie,v and permit is required fo., the insta!iatior, or alteration of the fire alarm and fire. T h. )I- I
2. Automatic fan shutdown is required for HVAC systemis that exceed 2,000 cfm design capacity. Provide a remote test and
inspect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector. HVAC duct smoke detector(s)
shall be tied into the fire alarm system.
3. Stair detail: Tread min : 11 - Risers mar: 7
Page 1 of I 1 Reviewed by Tony Jerger _ — — —� Date Oi 5-11-2021