Loading...
HomeMy WebLinkAboutProduct Approval- tile adhesive 3/9/2021 Florida Building Code Online ��pp n '� e� Yr•1� _ _ �de��sUey Iftlaw _ /f' er8ye: ...fie• t~r n 3 ? BCIS Home Log In User Registration I Hot Topics Submi j,S harge ` Stats&Facts i Publications Contact Us ? 8CT5 Site Map j Links c Search fo a r�l-1'2i1'66 4� I Product Approval RMEWEL>c�' Fop, ls USER:Public User CODE COMPLIANCE P Product Approval Menu>Product or Application 52arc _ ication Lis > IicatlQn Detail ltlu TY A R-- FL# F fiZ ,R9, /� \ Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer ICP Adhesives&Sealants,Inc. Address/Phone/Email 12505 NW 44th Street RECENED Coral Springs,FL 33065 (888)774-1419 Ext 201 MAY 1"9 2021 rylipelkonen@icpadhesives.com Permitting Department Authorized Signature Riku Ylipelkonen St.Lucle County rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email QualityAssurance Repres entative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity IAPMO UES Quality Assurance Contract Expiration Date 12/31/2023 Validated By John W. Knezevich,PE t Validation Checklist-Hardcopy Received Certificate of Independence FL6276 R9 COI 2020 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year SSTD 11 1997 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtvPAP%2bRzeteF4uypVgxu9x44X6QmBGV58%3d 112 3/9/2021 Florida Building Code Online r Date Submitted 09/29/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/11/2020 Date Approved 12/15/2020 Summary of Products FL# Model,Number or Name Description 6276.1 POLYSET RTA-1 Single component polyurethane foam roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6276 R9 II 2020 09 29 FINAL ER ICP RTA-1 FL6276- Approved for use outside HVHZ:Yes R9..pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+n/a/-187 Created by Independent Third Party:Yes Other: 1.)The design pressure limitation in this application Evaluation Reports refers to hip and ridge tiles. Field tiles are designed based on FL6276 R9 AE 2020 09 29 FINAL ER ICP RTA-1 FL6276- overturning moment resistance. 2.)Refer to ER Section 5 for .B%Pdf other Limits of Use. Created by Independent Third Party: Yes t3azk itvxt Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer. Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® 99 Creif aC ... hUps://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQWtDgtvPAP`/`2bRzeteF4uypVgxu9x44X6QmBGV58a/a3d 2/2 NEMO etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT ICP Adhesives and Sealants,Inc. Evaluation Report 02768.02.06-R9 12505 NW 44th Street FL6276-119 Coral Springs, FL 33065 Date of Issuance:03/21/2006 (888)774-1419 Revision 9:09/29/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71 Edition(2020)Florida Building Code sections noted herein. DESCRIPTION: POLYSET®RTA-1 LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: •,���;;�«�,,, • ='-. RobertJ.fVl.Nieminen,P.E. L r;-�• The facsimile seal appearing was authorized by Robert �:-.,�..a:s,,.�,::: Nieminen,P.E.on 09/29/2020.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018,MEMO ETC,LLC .S. NEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub-Category: Roof Tile Adhesive Compliance Statement: POLYSET° RTA-1 as produced b ICP Adhesives and Sealants, Inc., has demonstrated P P Y compliance with the following sections of the 711 Edition(2020)Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. StA rAK :Sections ;=> Pro fi °Stan and Year .. ..... 1504.2.1.1 Overturning resistance SSTD 11 1997 .Irrtity Examrtatlon Reference Date ERD(TST6049) Static Uplift—SSTD 11 E42730.08.13 08/23/2013 ERD(TST6049) Static Uplift—SSTD 11 ECM-SC6795.12.14-2 02/27/2015 Miami-Dade(CER 1592) HVHZ compliance 18-0131.02 07/12/2018 NEMO(TST6049) Static Uplift—SSTD 11 4-I0-18-001.05.18-1 05/15/2018 MEMO(TST6049) Tensile Adhesion(underlayments) 4S-ICP-18-001.07.18-R1 08/01/2018 NEMO(TST6049) Static Uplift—SSTD 11 4S-ICP-18-001.10.18-1 10/04/2018 MEMO(TST6049) Static Uplift—SSTD 11 4S-ICP-18-001.10.18-3 10/04/2018 NEMO(TST6049) Tensile Adhesion(ridge metal) 4i-ECM-20-SSCRT-01 09/29/2020 PRI(TST5878) Static Uplift—SSTD 11 PFI-006-02-01 05/09/2005 PRI(TST5878) Static Uplift—SSTD 11 PFI-008-02-03 12/14/2005 PRI(TST5878) Static Uplift—SSTD 11 PFI-008-02-04 12/14/2005 PRI(TST5878) Static Uplift—SSTD 11 FOP-009-02-05 Rev2 06/01/2015 IAPMO LIES(QUA10547) Quality Assurance Service Confirmation 08/17/2020 •R•e • 4.1 POLYSET® RTA-1 is a single component polyurethane foam roof tile adhesive distributed in factory, pre-mixed canisters. • 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or R902 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. 5.6 POLYSET®RTA-1 may be used with flat,low and high profile tiles having a current Florida Statewide Product Approval or approved on a local-level by the Authority Having Jurisdiction. NEMO ETC,LLC Evaluation Report 02768.02.06-119 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL6276-119 Polyse0 RTA-1 Revision 9:09/29/2020 Page 2 of 9 *. NEM0 etc. 5.7 Field tiles,meeting the limitations of FBC 1609.5.3 and installed using POLYSETm RTA-1 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with Table 21-16, 2HC, 2HD, 2GB, 2GC or 2GD of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition or FBC 1609.5.3,not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants,Inc. published installation instructions for Adhesive Paddy Placement details. RZ #r3iar i FieTtiiiE55iNfiULYSfT 3 i + AuopttABi E OVERwRifNG MoNii Nr P6ffFi33RMANCE DATA `� l ,�lMAft61MSQF-SAI:EiYiZt�ERDY�PPti!~D� .� .� ,- .7)te(Fi3C:16E1g _� ...A.dh�stv�;�P�dc�y P1�cefnerv�tSecttva 10� '` ;' `.Avowable - Ptacemerti 'Averturnirig '�`yl� Ptoflle Paddyi3eWils- t)etail , • , . (ft Ib Clay or Interdependent:Two(2)ribbons,11 grams each Concrete Flat/Low #1 Ensure minimum 8 inz contact area to underside of tile,and minimum 10 inz 50 contact area at the tile head lap Interdependent:Two(2)ribbons,11 grams each Concrete Medium #2 Ensure minimum 6 inz contact area to underside of tile,and minimum 10 inz 44 contact area at the tile head lap Clay High Interdependent:Two(2)ribbons: 36 a 22 grams tail-to-substrate #3 a 11 grams at head-lap Ensure minimum 12 inz contact area to underside of tile,and minimum 18 Concrete High inz contact area at the tile head lap 33 Independent: Pan Tile to Underlavment: Two(2)-7-inch long x-6 gram oblong shaped beads on underlayment,side-by-side,where the center of the pan tile contacts the deck starting-2 to 3-inches from the eave end of the pan tile ClayCap&Pan #4 Cap Tile to Pan Tile:One(1)-7-inch long x-6 gram oblong shaped bead at 93 (Barrel) each long edge of the cap tile,%to 1-inch from each edge,starting-2 to 3- inches from the eave end working towards the ridge. Turn cap tile over and install onto pan,butting the second course pan tile eave end on underlayment,side-by-side,where the center of the pan tile contacts the deck starting-2 to 3-inches from the eave end of the pan tile. Clay or Interdependent:Two(2)#8 wood screws at tail&one(1)ribbon,11 gram at Concrete Low/Flat #5 headlap 73 Ensure minimum 10 inz contact area at the tile head lap Interdependent:Two(2)#8 wood screws at tail&one(1)ribbon,11 gram at Concrete Medium #6 headlap 65 Ensure minimum 10 inz contact area at the tile head lap Clay High Interdependent:Two(2)#8 wood screws at tail&one(1)ribbon,11 gram at 44 headlap Concrete High #7 Ensure minimum 18 inz contact area at the the head lap 63 5.7.1 Data in Table 1 relates to installation over a TWO-PLY underlayment system,as detailed in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,using a hot-asphalt-applied,ASTM D6380,Class M cap sheet(commonly called a'30/90 system'). Alternate underlayment systems are those having a current Florida Statewide Product Approval and/or approved on a local-level by the Authority Having Jurisdiction,listed specifically for use with POLYSET®RTA-1. MEMO ETC,LLC Evaluation Report 02768.02.06-R9 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.6276-I19 Polyset®RTA-1 Revision 9:09/29/2020 Page 3 of 9 NEiili® etc. 5.7.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with POLYSET® RTA-1 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent multi-paddy method, an additional 2-to-1 margin of safety above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the'allowable overturning moment'. 5.8 Hip and ridge tiles using POLYSET® RTA-1 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition or the applicable design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3, not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. y `� � � � �11.LE?Vftl�$L�11PUFF1��fANEE P�RFQiI_MAIV�D,(k}'A � MARG7N5OfFE�Ya3SDYfiltP11 ). t. r Detait l Ifowab A .e Tile Substrate (Se."ctron Attachment 1Details Design '� r '• :-. ,. ..�D}� ' � :-Pressute'(psf) Interdependent: Concrete Clay 2x PT ridge board #8 Head:One(1)#10 x 2X"screw; 187 Overlap:1x6-inch x—10.5 gram East Coast Metals"Trim LockTM"(FBC FL5394): Interdependent: Clay or aluminum or On Trim-Lock'""metal:One(1)—7- Concrete East Coast Metals"Trim LockTM'Plus"(FBC inch long x—10 gram oblong shaped 93 FL5394):aluminum,Galvalume°or stainless #9 paddy centered on metal. steel At Tile Headiap:One(1)'"7-inch long Clay or East Coast Metals"Trim Lock'"'"(FBC FL5394): x—10 gram oblong shaped bead at Concrete Galvalume®or stainless steel tile headlap. 110 z • =t 6.1 POLYSET®RTA-1 and the the roof assembly shall be installed in accordance with the manufacturers'current published i H instructions,but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,subject to the limitations in Section 5. 6.1.1 Installation of POLYSET® RTA-1 shall be performed by applicators that hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants,Inc. 6.2 Underlayment shall hold current Florida Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable use with POLYSET®RTA-1. The underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual,Sixth Edition or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 6.3 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. • S. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Norton,OH IAPMO UES—QUA10547;(909)223-4422;barrv.iohnson@uniform-es.ora NEMO ETC,LLC Evaluation Report 02768.02.06-119 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.6276-119 Polyset°RTA-1 Revision 9:09/29/2020 Page 4 of 9 NEM® etc. 10.1 [letatkl1at Proftfe Tile Stcetzgihenhig whs 4 r _ a n UndeMWibf711e €'�#dy4trTieek DaGN F ft¢HxE7flEa1(f Et`i'lle�OttTS@Ltt1'e • �' r Yh K TF r _ � r s Per)at1 Tp��Tito -��, � Els�n,edHtr<¢otlfahg, 3 1. 6 �S r r x Eav$Coutse,L;ne r� Eava CtpsE)re ,,,F ;Stait,Ea've Coars$:Perldsss'' . rsl Tite touts®Lin 10.2 bent#2,loetr`M + ifi Profile'17te 15attAr, Np~90 a '- `Dsspehse8 Har�mn�Hy 1 Eavc�99tse;'Lnte '� :✓' t 3 Feve Clsrsure s Y' $last Eave Course-Paddies at t#e C=w Line NEMIO ETC,LLC Evaluation Report 02768.02.06-119 Certljlcote of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL6276-R9 Polyset®RTA-1 Revision 9:09/29/2020 Page 5 of 9 NEMO etc. 10.3 Detaii#3 High Profile Tlie t?anot'Yde _ v PaddyonTepUtTda '. _ F3EspemG'tf�ios�nto�l atfie¢�tyl:e� } 4 is r .l St A t _� i Y {x d- Y. 4.2X 113 f S 1 } a 5 1 e � a i c ' 3 s l aveGiosute 3: k 3fc StorWaddy,Undemeath Pak' Hkgh'Profile Tile CC.4se Lm— 10.4 Dait#4 T,Wo Piece Barret{Cap&Pan)Tde �.. .,ram r n OtNli):`PPaddy' 4 on eacti stria under' Sh k nr caaefli.ies(Detap iS ©lion T 3radd'�slue t:y a silo uDs6371�Lies 3 Y _ - �:� '1 dlhquch bite lalde.^: r � Faee;CltJstliB :. T�o{2):jU`:Oblbn9 paddiss silo#ry siife to undet,panlllas 2-Ptemearta)Profle {eavezxicuseonty) NEMO ETC,LLC Evaluation Report 02768.02.06-R9 Cer ificote of Authorization#32455 7TM EDITION(2020)FBC NON-HVHZ EVALUATION FL6276-R9 Polyset°RTA-1 Revision 9:09/29/20ZO Page 6 of 9 NEMO etC. 10.5 t)etail#5� Cow) tai Profits Tle;Hyfirld System .'�1W�Qi1r8ilVfQ�F�15 t , Tuai2)�8 k SCra�S:irlFactoF'� NaBJtions '+Ciadera(6eo FLYe :. s �.r s hhOL of TUa Y uEriue�,uctai9 3 1 i EfiYH GOSVr6 � 10.6 stem ..-Pan A(Ti#e - Y 'TYrp l..p u�S�S.ctays yf ::faC 7ty do toq"r7r,Sv r r _ 6��teo?esdleii<rxffaity, ^ ` 61b £uP r, r Lma, r Low profife MEMO ETC,LLC Evaluation Report 02768.02.06-R9 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVH2 EVALUATION FL6276-119 Polyset®RTA-1 Revision 9:09/29/2020 Page 7 of 9 ut4NEMOjetc. 10.7 Detatt#t7�� Htgh Prgf+te Tite,Hybrid$ stern• Parivtrre FactaWtfo Locs(fgfi5 �sua,rn�TtiAf*•nEe :- �Dt�ans�tHoE3ntatiy.„ y t y�tKead LaA � d P ..' x � M 1 ? r l s 1 r .Ir0Yt33.,51(,r4 �. x r t Lflie} a.` x x 10.8 Dexa7t#8,"7fip and Rtdei�terde �ndentwlth scitQw) rc . fi Idn �. Cd - �rted� �s Fasbenert Mew,t�i i� €�t31lJtrOIlB'�1e�3" ' tr1Tl : MEMO ETC,LLC Evaluation Report 02768.02.06-119 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.6276-119 Polyset®RTA-1 Revision 9:09/29/2020 Page 8 of 9 O. NEMC)Ietc. 10.9 beak#9. kfii� r�tdidge(��terdepe �entle�etne�tj .q Obtagg Paddy 91 �. tax* ;. I Vas 7- -END OF EVALUATION REPORT- NEW ETC,LLC Evaluation Report 02768.02.06-R9 Certificate of Authorization#32455 7-EDITION(2020)FSC NON-HVH2 EVALUATION F1.6276-119 Polyset®RTA-1 Revision 9:09/29/2020 Page 9 of 9