Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED coppola product approval4/6/2021
Florida Building Code Online
: f Intllit
SCIS Horne Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact us BCIS Site Map Links Search
dopr,�r-',
�l Product Approval
� USER: PubEc User
Product Approval Menu > Product or ApyGcation Search Application List n Application Detail
FL #
FL22363-R6
Application Type
Revision
Code Version
2020
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Masonite International
Address/Phone/Email 1955 Powis Road
West Chicago, IL 60185
(800) 663-3667
sschrelber@masonite.com
Authorized Signature Steve Schreiber
sschreiber@masonite.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management institute
Referenced Standard and Year (of Standard) Standard
Year
ASTM E1886
2013
ASTM E1996
2014
ASTM E330
2002
TAS 202
1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 11/20/2020
Date Validated 11/23/2020
https:l/www.floridabuilding.orglprlpr_app dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRgHEf8HYBpjQdlVoNoAVYGng%3d%3d
V4
416/2021
Date Pending FBC Approval
Date Approved
Florida Building Code Online
11/29/2020
Summary of Products
FL •# •, Model, Number or Name Description
22363.1 Fiberglass Side -Hinged Door Unit 6'-8" Opaque I/S Single Door
Limits of Use — Certification Agency Certificate
Approved for use in HVHZ: Yes FL22363 R6 C CAC Ni013717.17-R4.pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant, No 05/31/2025
Design pressure: +60/-65 Installation Instructions
Other: Evaluated for use in locations adhering to the Florida FL22363 R6 11-FL0187.pdf
Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute
where pressure requirements do exceed the design pressures Created by Independent Third Party:
listed. 3'-0" x 6-8" max nominal size, Hurricane protective Evaluation Reports
system required in HVHZ, but not in the Wind Borne Debris FL22363 R6 AE 514010B.p�f
Region. See DWG-MA-WL0187 for details, FL22363 R6 AE 514014B.pdf
Created by Independent Third Party: Yes
22363.2 .Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +60/-60
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0187 for details.
22363.3 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region, See DWG-MA-WL0187 for details.
22363.4 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0189 for details.
22363.5 Fiberglass Side -Hinged Door Unit
i
Lim -its of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6-8" max nominal size, Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0193 for details.
6'-8" Opaque O/S S"ngle Door
Certification Agency Certificate
FL22363 R6 C CAC 4I013717.17-R4.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 II -FL0187.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE 514010B.pdf
FL22363 R6 AE 514014B.pdf
Created by Independent Third Party: Yes
6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL2236 R C CAC NI01 717.17-R4.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363_R6 II-FLQ187.pd
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE 514008B.pdf
FL22363 R6 AE 514012B.pdf
Created by Independent Third Party: Yes
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22363 R6 C CAC NI013717.03-R3.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 11-FL0189_pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE 5140086.pof
FL22363 R6 AE 514012B.pdf
Created by Independent Third Party: Yes
6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
w/o Sidelites
Certification Agency Certificate
L22363 R6 C CAC NI013717,04-R3.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 II -FL0193.ddf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL223 3 R6 AE 514008B pdf 3
FL22363 R6 AE 514012B.pdf
Created by Independent Third Party: Yes
https:/lwww.floridabuilding.org/prlpr_app_dtl.aspx?paraam=wGEVXQwtDgs31M6m9%2fKBXPOv7Ro8yOHRgHEf8HYBpjQdlVoNoAVYGng%3d%3d 2/4
4/612021
Florida Building Code Online
22363.E Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant- Yes
Design Pressure. +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0195 for details.
6'-8" Impact Glazed I/S or 0/5 Single o Double Door w/ ar
w/o Side tees
Certification Agency Certificate
FL22363 R6 C CAC NI013717.05-R5.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 II -F 0195.pAf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE 514o08B.ydf
FL22363 R6 AE 514012B.p(i
Created by Independent Third Party: Yes
22363.7 Fiberglass Side -Hinged Door Unit 8'-0" Opaque I/S Single Door
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ; Yes
Impact Resistant: No
Design Pressure: +60/-65
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0188 For details.
Certification Agency Certificate
FL22363 R6 C CAC NI013717:13-RBRdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 II-FLQ188.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
EL22363 R6_A.E 514009E pdf
FL22363 R6,AE 514013B.pd
Created by Independent Third Party: Yes
22363.8 Fiberglass Side -Hinged Door Unit
8'-0" Opaque O/S Single Door
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22363 R6 C CAC NI013717 18-R3 pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
05/31/2025
Design Pressure: +60/-60
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22363 R6 II-FL0188.p_df
Building Code, including the High Velocity Hurricane zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do exceed the design pressures
Created by Independent Third Party:
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective
Evaluation Reports
system required in HVHZ, but not in the Wind Borne Debris
FL22363 R6 AE 514QL)25.pdf
Region. See DWG-MA-WL0188 for details.
FL22363 R6 A"14 1 5.pdf
Created by Independent Third Party: Yes
i
22363.9 Fiberglass Side -Hinged Door Unit
V-0" Opaque I/S or O/S Single or Double Door w/ or w/o
Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-D" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0188 for details.
22363.10 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant; No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0190 for details.
22363.11 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Certification Agency Certificate
FL22363 R6 C CAC NID13717.18-R3.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R II-FL0188, df
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE 514007B.pdf
FL22363 R6 AE 514,". B.qd
Created by Independent Third Party: Yes
8'-0" Glazed I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22363 R6 C CAC NI013717,08-R2.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 II-FL019dpdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party;
Evaluation Reports
FL22363 R6 AF 51400713.Ro
RLZ2.363 R6 AE 514011B.Rdf
Created by Independent Third Party: Yes
8'-0" Impact Glazed I/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22363 R6 C CAC NI01 7 7.-R4.pdf
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRgHEfBHYBpjQdlVoNoAVYGng%3d%3d 314
4/6/2021
Florida Building Code Online
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +40/-45
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the high Velocity Hurricane Zane, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x W-0" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0196 for details.
22363.12 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +45/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x W-0" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0196 for details.
22363.13 HPC Fiberglass Side -Hinged Door
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +47/-47
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
'listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ and in the Wind Borne Debris Region.
Door top rails stamped "HPC". See DWG- MA-WL0192 for
details.
22363.14 HPC Fiberglass Side -Hinged Door
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
Door top rails stamped "HPC". See DWG-MA-WL0191 for
details.
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 11 -FL0196.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE 514007B,pd
FL22 R6 AE 514011B.pAf
Created by Independent Third Party: Yes
8'-0" Impact Glazed O/S Single or Double Door w/ or w/o
Sidelltes
Certification Agency Certificate
FL22 63 R6 C jqAC NI013717.09-R4.pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 11-FL0196.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE ' 14007B.pd
FL22363 R6 AE 514011B.pdf
Created by Independent Third Party: Yes
8'-0" Glazed I/S or O/5 Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22363 R6 C CAC NI0137.17.07"R2•pdf
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 11-FL0192.pdf
Verified By. National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
Fi_22363 R6 AE 514007B.p,-df
FL22363 R6 AE 5140116 pdf
Created by Independent Third Party: Yes
6`-8" Glazed I/$ or O/S Single or Double Door w/ or w/o
Sidelites I
Certification Agency Certificate
FL22363 R6 01 717, -R .pd
Quality Assurance Contract Expiration Date
05/31/2025
Installation Instructions
FL22363 R6 II -FL0191.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R6 AE 514008B.p�f
FL223.6a R6 AE 5 4 12 .pAf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 PSI pne: 850-487-1824
The State of Florida is an AA/EED employer. 20_P.Mq ht 2007-201 Skate of Florida, ;; PrNacg Statement :: Accessibility Statement te.-ment :: Refund Statement
under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electmnlc
m0 to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *pursuant to section 455.275(i.),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.s., please click here .
Product Approval Accepts:
® as M-0 s tack
Credit Card
Safe
https:llwww.floridabuilding.org/prlpr_app_dU.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRgHEf8HYBpjQdlVoNoAVYGng%3d%3d 414
O O
O: [ kn O C
n
N m 'o n d
m .c
0 9
� oa
cp L
� q a
N N •� •N CE CO 4�
a, cti -
od��
�z
O � rn cc
iO• Vy � 02
w, „o
c ��W NSF
�.•�Q~ry��
00 N — is d
fir. C ..�i Otry O oat
W.1 rk
�aU �10,
tA sLn W, w eov A
ti
a
C � �
CL V V
C
�a
� d
A
fi
w Le d
cui C
/_. `
Y a
m p
E,v
o�oo�
�yba28^er2
nen
Boa
x[7�ooOo xQ
. r
uCL-w xd
N
G
xa�^
4i.
aC7
j���ct,3o�n,�o�in3o�raR�yry�'ne3
�
N
W A p
ti` y
Fpp
N
N
r-e U
bx
x z ¢• u
ttl a t6
�y
aan
Q
C
cq C4
En
DO
m �
N L
L
y m
Q m
n N
4
N
v w
I`. 00
INN
N
Cl 00
[+f W
(�1 00
M 04
M 40
i p i o
o
a
o
v)
a
�
o 0
v) ,n
0
a v,
o c
w . y
aW W h
O
O
CDC)
�
O
T kn
+ +
A +
+
+
+
+
+
+
+
ca
00
00
00
00
oa
-
c o
00
oo
a
o
o
o
o
CD
o
N
N
M
16
VJ
�O
O�
C1+
cNV
I� O
Q
i
�
�
W CO
-2 CS
a O
m
❑
`Q
�
G
O
O
O
U
to
A
A
an
x
0
Mrl
y N
CD `�
nv
vuo
Tr
-N N
r
# i,
u �
4Z
O
O 4Z �
yePs
b �
F
C
IPC
a �
u
p �
2
h
n
�z
Q
H
92109 1 `ODVOIHO 1S3M
GV08 SIMOJ 996 b
dYOO IVNOIIVrvE&N, g.UNOSVM
OON 7v&w
91MV
Thi8W3'
aaff ssm
X�d m I
.O.,.a
xvw o29
,SLB'!9 M$Of1 3lP u 'XWY
wp
N
h y =g�'
UKg /�j to�_ �yapNyy��� D
4fi,RRN pZ213
Z O�
O �� �� tl3�N ff0
onwzo Tw G
pUG ma; U��n in wA
...a88E5 min o z
a� �W zc,z z�u o0
p U U`
z W©JJw z- 2�a O y
CZy 2s 2x� d'y U
W �ii K so 3T US 00
W
VI
I
f-�
SNOlSVt321
31VO
4N
MU
SMs
VIVO (131VQdR
L! LZ L!
tl
sMs
dH Q3aaH
6L Z 5
9
sMS
JNIZVl9 31VNa31IV
93 8! Z!
9ilOQ
6R1311C3„
l.onaoad
n
lEn
k
Id
oI
Ld
0
En
a
S U30 v
99109 71 `OOVDiHO lS3M SWUM7 MOHOW
OdQN SfN1Qd ��61 'Tlij 3SSV aO Wd
.LLW`l wx 37ffm
WOO 741111 UVAIL19INI 3.UNOS1/f'Y aura SSVTUM .s ;s
.13f1Md WW 21p1:9 X1
x
SL£'L
0
I,J U w
,osa-L� — ,S•g
0
w °a
415 A Iltll1C13 3210LV ti
W
0 W
T S S
F��r
0 0 � 0
mTZZ �t
F
w o wEr
O
G] � JH
Of OQ x rS
(nL
ama
~C)¢ Q
� L'i
�F �
u'
QI
w
ti
N O
i7
Q33tldS .0-lV O3 3NOW f,
M
�j
i•y
j
�
-TT
m �
�D jp
_f
T
6
i
c
I �
ca
wr
-JI „SLf'L En
a
x
�
o
1
Cc
�
� f
s
co
x k
N
x
0 a
0
x
W.
O
11r
aw
Oi
2
U7
L LJ
Of
2
h—
oI�i 1-91
.,I�;I9Ia.
M.-Sm.
0
98 109 71 `00VO HO 1S3M
OV08 SiMOd 9961
HOO 7VNOUVN8 MN! 31JNOSM
SNDuMI9NI80HDNV
xisnassx aorvd
SNOISI3a
�
vi
3L6q
'ON
Sh4S
SN<s
VIVO G3kwcdn
dH ©3a4V
L E LZ E E
8E Z 5
V
9
Ivn wo 2RM
uwv swMai .s-,s
t�naoxd aooa wwitxl
SMS
9NIZVi9 31VN2l3LlV
MI .n —n
M]
J N
' 9 U .9
N
030VdS k-nvnt)3 3NOW tr
N
2
N
N
ui
U $
o�
g�
Ly
x
J
Q
�¢e
f7 N
O e
00
�©
pZ
Q Z
04
Z O
E-
J
M 7
O
U
7�
p
=W
�x
Z
vi
0Lij
Z m
U Y
Z
N0Z
MQ
2
\tea
z-
J
�
p-
m
O�
zw
pOC?
d � O
o
Y�z
a
�UU
_
�e U) x
Y v
E
{ ci
N
Q ih
F"-
Z
µ'
O
z
�
_
U
.e
ab
U
U
�
Q
= w
w3.4_'p
© w N W
p _j
U m
0 Kyw)N�
W Lii Q t-- Mw.. Z'w
zzz
WW
Zo-Va) Q4p4�U~
LD
Z
UO3L`7aOcwj�z
F- LLAJ
-
Z w p E r a LLin W
5ML,JLjLd3 P zU
_j F-- Z<%.W-CC) Z<
rZ�LY \F-aM
W
z�rnx w�
rVyet]wQVst-
W Q cN9¢�L~NNL¢��Z
w 00 z m ra0
UZOF-ZW 2S
0
2 UU, 0 �O aUbN
Q(L_ a z z
nvL,m!- QQ�G]
VI
x
0
NVi
WW
(j
QZQ
C®w
�
0Q
g
v'
Q �
OY
NUw �®
B
¢z
�Q
SIR
zg
F-
z
Ld
U
W w
w
O L,
0
O
F-
��
cr>
LLJ U
}
Z
w U 4
J
W
¢t
w
UO
Oo�
a er7
�a
LLJ
OZg
0 u)
�i--
v,z
w¢z
a
'--LIJ�LLJ
=�Q
J m
o w
b
m
w
E
,pr¢-
o
O U
�o
L7JW
O Q
W =
z
¢ wo
wpwz_F
C3 a
w
c
aZF:
Let W €Zi3\
T
toLJ
(1)
z
Z
Vl
LLI
Wpm
ulw 1�/7
OwO
w� L.W
F-(n
WLLJ Q�F"
HQ J
Q f- j
LLJ
2z
UZEW
O
F`
f17 Q:
W<
X W
Z I.7
00-Nw
C O
�n
mw
fY W
OZ
�
L
� �
p0 g
UZ
LJFA
N
+S
d
�8[D9 �! `ODbD1ND �S3M
SWBO v
s^loue�aoI aor�rsa
Ms
SNaISV N
ct3�z tt
v
n
OVO `N SIMOd 956 b
7Aia ss+ ao laud
sans
JH a3aav
s t Z
s
w ti
d00 IVAR)rIV%ifi2Lnir 311NOSM
Im KM Tanon
did aao� 7�VLt�Ix�,
SI4lS
SMS
�NI2V la 31 dtV2E311t!
tlC7N a3Atlld3NNl
8 t 8 t
az 8 t L
a
Ell
r.aT
Q
G
N
1 W
�
u
V
6
Q
e
p�
c
1i1i
LL
( j
i���f N
O
fa11
G C
W
O
L. Roberto Lomas P.E.
1422 Woodford Rd Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514008B
434-889-0609 Date: 1011012017
rllomas ]rlomas e.com
Test Report: NIA
Product: Double Door with and without sidelites 12WW' (wood frame)
scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Florida Building Code 7th edition (2020).
Anchor capacity in shear condition:
Solid members w/ & w/out gap:
a. With threads present in shear plane
Fastener type: #10 woad screw (NDS 2018, TR12)
Nominal diameter: D: 0.190 in Gap: g: 0,0000 in
Root diameter: Or: 0,152 in Moment arm: 0.0000 in
Minimum required penetration: p: i,140 in Screw bending yield strengthL Fib = 60,000 psi
Side member: Douglas Fir -!.arch (6=0.50) Main member: Spruce -Pine -Fir (6=0.42)
Side member thickness: t,- 1.000 in Main member thickness: tm= 1.500 in
Side member dowel bearing strength: Fu = 4,650 psi Main member dowel bearing strength: F_, = 3,350 psi
Side member dowel bearing length: 4 = 1.000 in Main member dowel bearing length: Im = 1.140 in
Mode 1m
qm = 636.5 Ibs/in
P = 725.61 lbs
Ku = 2.400
4- 302lbs
Mode I,
qs= 884lbs/in
P= 884lbs
Ko = 2,400
2K= 368 lbs
Min. Design value: Z= 110 lbs
Mode 11
A: 0.0007
B: 1.07
C:-427,674
P = 331 Ibs
Ko = 2.400
Z= 138 lbs
Duration Factor: Cp = 1.6
Made UT,,,
Mode rV
A: 0.00135
B: 0.000
C: -93.6
P = 263 lbs
Ko = 2.400
Z= 110 lbs
Allowable Design Value (ZCo): Z'= 175 lbs/anchor
Fastener type: 1/4 rrW Tapcan Tabulated values
N.O.A.16-1222.06
Substrate: HoPow black
Minimum embedment: 1,25 in
Actual edge distance: 2.50 in
A:
0,00096
B:
0.57
C:
-253.623
MS =
46,8 in-ibs
P =
297 lbs
Ko =
2.400
Z=
124 lbs
Made Mx
A:
0.00107
B:
0.5
C
-267,699
Mm =
46.8 in-lbs
P =
319 lbs
Kp =
2.400
Z=
133 lbs
edge
distance
spacing (in)
2.00 1 4.00
2,00
130 161
4.00
163 202
Actual C To C spacing:
3.00 in
Allowable Design Value:
Z"= 155 Ibs/onchor (per interpolation when needed)
Fastener type:
#10 Tek screw
Substrate:
18 GA, Steel
Tabulated design value:
Z= 1266 lbs
Safety factor:
Fs= 4
Allowable Design Value (ZFs):
Z-= 316 tbs/anchor
Minimum anchor capacity: 155 lbs/anchor
Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity,
Anchor calculations, minimum required anchors
36.38 36.38 Design pressure: 60.0 psf
Al 117AI Y
A2� Y
79.25
Al Al
72.75
37.50
36.38 36.38 37.50
Al
A4
A4
Al
Y
13
79.25
Al
A4
147,75
1 of 4
Zone
Area
?
{ft)
Load
(lbs)
End-
(in)
Max,
O.C.
(in)
Anchor
Result
Cap.
(lbs)
4tY
Load
(Ibs)
A,
2.3
138
N/A
N/A
155
1
138
OK
A2
7.7
463
6,00
21.00
155
5
93
OK
A3
1 7.7
463
N/A
NIA
1 155
3
154
1 OK
Design oressure: 60.0 ncF
Zane
Area
{ft2)
Load
(lbs)
Ind.
(in)
Max.
O.C.
(in)
Anchor
Result
Cap.
(Ibs)
4ty
Load
(lbs)
A,
2.4
1 146
N/A
N/A
155
1
146
OK
Az
7.9
473
6.00
21.00
155
5
95
OK
A3
7.
4468
N/A
N/A
155
4
117
OK
A4
2.3
235
N/A
NIA
155
1
138
OK
A�
7.7
463
N/A
N/A
155
3
154
OK
\wkI1(it////
R - L4
0 YJ
.TA
4
ICI_
oe
//;i 1OA(AL�E
Luis R. Lomas P.E.
FL No.: 62514
9/2/20Z0
L. Roberto Lomas P. E.
1422Woodford,4d. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514008B
434.68M609 Date: 10/10/2017
rllcmas Iriomas e.00M
Anchor Locations:
Double door
79.25
2of4
6.00 TYP. -r• - 6.00 TYP. - —. 18.19 7YF_ - --
f
6.00
18`
MAX
O.C.
6.00
3.00 TYP.
N"' R " L 0
�� •••••�l �i
4-T�AFTE
"OFOlk
• �—
.
OR1'0'
jS0oAtAt1
Luis R. Lomas P.E.
FL No.: 62514
9f212020
L. Roberto Lomas P. E.
1432 woodtord Rd. Manufacturer: Masonite
Lewisville, NO 27023 Report #6: 514008B
434-698-0609 Date: 1011012017
rgomas Irloma,,;gq m_
Double door with sidelites
36.30 37.50
i-+ 1 8.75 TYP. �+
6.007'(P. 6.00TYP. ._'-'_.__y'iw
3.00 TYP. �— N..�
6A0
1 e"
MAX
O.C.
9.25
T
-
e.00
3.of 4
EN
■
TAT OF
•
I% •
W
AI.t����
Luis R. Lamas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lorms P.E.
1432 Woodford Rd.
Lewisville, NC 27023
424-688-0609
Manufacturer: Masonite
Report #: 5140088
Date: 101101201 T
rilomas@lrlornaspe.com
Installation instructions;
1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 114" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1I2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
2. FOR ANCHORING THROUGH FRAME INTO MASONRYICONCRETE USE 114" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 114" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 112"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 112" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
4. ALL FASTENERS TO BE CORROSION RESISTANT.
5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOWIFILLED BLOCK PER ASTM C90 WITH Frn=2,000PS1 MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSIIFU=52KSI OR ALUMINUM 6063-T5 FU=30KSI
.052" THICK MINIMUM
6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN.
7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD,
8. 1X BUCK OVER MASONRYICONCRETE IS OPTIONAL.
9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-112" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL.
10. WHERE WOOD BUCK THICKNESS IS 1-112" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS.
11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
4 of 4
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisvdki, NC 27023
Manufacturer: Masonite
Report #: 514012B
434-68"6'09 Date: 1011 G12017
rllomasO-Homaspe.rom
Test Report. N/A
Product. Double Door with and without sidelites 12'x6'8" (composite frame)
scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Florida Building Code 7th edition (2020).
Anchor capacity in shear condition;
Solid members w/ 4 w/out gap:
a. With threads present in shear plane
Fastener type: 010 wood screw
(NDS 2018, TR12)
Nominal diameter: D:
0.190 in
Gap:
g: 0.0000 in
Root diameter: Dr:
0.152 in
Moment arm:
0.0000 in
Minimum required penetration: p:
1.140 in
Screw bending yield strength:
Fyb = 80,000 psi
Side member: PVC
Main member:
Spruce -Pine -Fir (6=0.42)
Side member thickness: t,=
1.000 in
Main member thickness
tm = 1.500 in
Side member dowel bearing strength: F. =
10.000 psi
Main member dowel bearing strength,
F_ = 3,350 psi
Side member dowel bearing length: 1.7
1.000 in
Main member dowel bearing length:
1m = 1,140 in
Mode Im Mode 1,
Mode 11
Mode IIIm Mode III,
Mode
IV
qm=
636.5lbs/in qs= 1900lbs/in
A: 0.0005
A: 0.00066 A:
0.00092
A:
0.00105
P =
725.61 lbs P = 1900 lbs
B: 1.07
9: 0.57 B:
0.5
B:
0.000
Kc =
2.400 Ka = 2,400
C:-681.799
C:-253.623 Ca
-521.824
C:
-93.6
Z.=
302 lbs Z,= 792 lbs:
P = 510 lbs
Ms = 46.8 in-lbs Mm =
46.8 in-fbs
Ka = 2.400
P = 324 lbs P =
529 lbs
P =
299 lbs
Min. Design value: Z= 125 lbs
Z= 212 lbs
Kb = 2,400 Ko =
2.400
Ka =
2.400
Duration Factor: Cp = 1.6
Z= 135 lbs Z=
221 lbs
Z=
125 lbs
Allowable Design Value (ZCo): Z'-
199 lbs/anchor
Fastener type: 1/4 TTW Topcon
Tabulated values
N.O.A.16-1222.06
Substrate: Hallow block
edge
dlstancc
spacing (inn)
2.00
4.00
2.00
130
16I
4.00
1b3
202
Minimum embedment: 1.25 in
Actual edge distance: 2.50 in
Actual C To C spacing: 3.00 in
Allowable Design Value: Z"= 10 lbs/anchor (per
interpolation when needed)
Fastener type: #10 Self tapping screw
(Calculations per 2015 Aluminum Design Manual, section J.5.5)
Nominal screw diameter: D: 0.190 in
Screw root area: A,
0.0161 iW
Actual edge distance: de: 1.086 in
Screw shear ultimate strength: F,,,
54.0 ksi
Per table J3.2 of 2010 Steel Construction Manual 14th Edition
Side member material: Vinyl PVC
Main member material: 6063-T5 aluminum
Thickness: tI 1.000 in
Thickness: tc
0.052 in
Ultimate tensile strength: FTu, 14 ksi
Ultimate tensile strength: P z
22 ksi
Nominal strength per bearing (side member): Rn = 20tiF,u,
Rnl = 5320 lbs (Eq J.5-12)
Nominal strength per bearing (main member): Rn = 2Dt2Ft z
Rn2 = 435 lbs (Eq J.5-12)
Nominal strength Per tilting: Rn = 4.2(t23DY"Ftuz
Rn = 479 Ibs (Eq J.5-13)
Nominai screw shear strength: Rn = A,F_/2.25
Rn = 654 lbs (Eq J.5-14)
Safety fatter: 07 3
Allowable shear and bearing capacity: Pus 145 lbs/anchor
Fosterer type: #10 Self tapping screw
(Calculations per AISI $100-16 and AISC 2017)
•_�
Nominal screw diameter: D: 0.190 in
Screw shear ultimate strength: F,u
54.0 ksi
Screw root area, A, 0.0151 in2
Per table J3.2 of 2010 Steel Construction Manual 14th Edition
Side member material: Vinyl PVC
Main member material: Metal framing
Thickness: t, 1.000 in
Thickness t$
0.0.. '-
ultimatetensilestrength: F., 14 ksi
Ultimate tensile strength: F,2�r����,!
Nominal strength per tilting: Rn = 4.2(t23D)�Fu2
Nominal strength bearing (side Rn 2,7Dt,F,,,
Rn = 1001 lbs (Eq E4.3.1-1)
��� R , L 0
��
per member): =
Rnl = 7182 lbs (Eq E4.3.1-2 and -4)•r
• ■ •
•``j
Nominal strength per bearing (main member): Rn = 2.7DtzFuz
Rn2 = 1280 lbs (Eq E4.3.1-3 and -5)
`�� V •
Nominal screw shear strength: Rn = A,F„J1,25
Rn = 654 Ibs
�p-
.� '� �
Safety factor: ❑= 3
*•-"
.,`►* 0 51 •
Allowable shear and bearingcapacity: P„ 218 lbs/anchor
aP tY�
•
Minimum anchor capacity: 145 Ibs/onchor
a� u
TAT E 0 F
Note. Anchors with the least capacity is used for calculations to qualify anchors with
A ty 4 fY
higher capacity.
9 P ry
ZZ
���`S;
.•�
: 0 R %Vt"
©1VA�.�������
1 of 4
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P. E.
1432Woodford Rd. Manufacturer: Masonite
LewlsWfle, NO 27023 Report k 514012B
484-68"609 Date: 1011012017
rllamaad rlornaspe-corn
Anchorca_lcufalions, minimum reouired anchors
36.38 36.38 besign pressure: 60.0 P sf
-71
Al Al
�YE � 79.25
Ai Al #
72.75
37.50 36.38 36.38 37.50
^ Al
A4
A4
•• Al
�/
Y
A3
79.25
ik
Al L
A3 AS
4 A4
LA4
A3; \
Al
147.75
Anchor Locations:
Double door
6.00 TYP. - -,
-- -- 6.00
l $"
MAX
0-C.
7925
6.00
2of4
Zone
Area
(ft2)
Load
Obs)
Ind.
(in)
Max-
O-C-
(in)
Anchor
Result
Cap.
(lbs)
�Y
Load
(tbs)
AF
2.3
138
N/A
NIA
145
1
138
OK
A2
7.7
463
6.00
21.00
145
5
93
OK
A3 1
7.7
463
N/A
NIA
145
4
116
n
!lesion pressure: 60 0 ncf
Zone
Area
(ftZ)
Load
(Ibs)
Ind.
(in)
Max'
O-C-
(in)
Anchor
Result
Cap.
Obs)Qty
Load
(Ibs)
Ai
2.4
146
NIA
NIA
145
2
73
OK
Az
7.9
473
6-00
21. 00
145
5
95
OK
A3
7.8
468
N/A
N/A
145
4
117
OK
A,
2.3
138
N/A
N/A
145
1
138
OK
A5
7.7
463
NIA
N/A
145
4
116
OK
36.38
0.00 TYP. - l8.19 TYP.....-
3.00 TYP, i.
i
`�\Xjliif!/1//
q, P. L
4.--tATE gyp•1,.
r0�F:�aR[DP.
NAL
iOIE���~
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L_ Roberto Lomas P.E.
1422 Woodford Rd. Manufacturer: Masonite
LowisWle, NC 27023 Report #: 514012B
434-698-0609 hate: 10/1012017
dlomasO),Irlomaspox
Double door with sidelites
1 — — 37.50
�- -- 18.78 TYP.
6.00 TYP. Imo+—.•-� 6.00 IYP.
3-00 TYR F+
79.25
3of4
37.50
R , L
�rJ1r •71C_..
rT O
ZJvijp�//ONAIL �
lI[I
Luis R. Lomas RE
FL No.: 62514
9/2/2020
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0608
Manufacturer: Masonite
Report #: 514012B
Date: 10/10/2017
rllomas�pecom
Installation instructions:
1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING, OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT" INTO SUBSTRATE WITH 2 1/2"
MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW.
3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
4. ALL FASTENERS TO BE CORROSION RESISTANT.
5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,006P81 MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FYW33KSIIFU=52KSI OR ALUMINUM 6063-T5 FU=30KSI
.052" THICK MINIMUM
6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN,
7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD.
8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
9. WHERE SHIM OR BUCK THICKNESS 13 LESS THAN 1-112" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL.
10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS.
11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE, SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
4 of 4
4Q 51 '
-.'tATE OF _
/.ems
�ONAI.0����
Luis R. Lamas P.E.
FL No.: 62514
9/2/2020