Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3216 perigrine falcon dr
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 05/26/21 Permit Number: Or. ILUculp: c tti Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential X 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR:MECHANICAL AC CHANGE OUT PROPOSED IMPROVEMENT LOCATION: Address: 3216 PERIGRINE FLACON DR Property Tax I D #: 3424-800-0019-000-3 Lot No. 5 Site Plan Name: CAROL GRIEMSMAN Block No. 66 Project Name: CAROL GRIEMSMAN DETAILED DESCRIPTION OF WORK: l AC CHANGE OUT G 63 New Electrical Meter Second Electrical Meter CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Windows/Doors Pond Electric _ Plumbing _ Sprinklers _ Generator Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 5952.65 Utilities: —Sewer —Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name CAROL GRIEMSMAN Name:MICHAEL FORGIONE Company: UNIVERSAL AIR AND HEAT Address:3216 PERIGRINE FALCON DR City: PORT ST LUCIE State: Address:5460 ST RD 84 # 12 City: DAVIE State: FL Zip Code: 34952 Fax: Phone No.772-212-7558 Zip Code: 33314 Fax: 954-318-0584 E-Mail. Phone No954-581-7110 Fill in fee simple Title Holder on next page ( if different E-Mail PERMITTING@UAHAC.COM from the Owner listed above) State or County LicenseCAC058142 If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNE Name:_ Address: City: Zip: ENGINEER: _&_ Not Applicable Phone FEE SIMPLE TITLE HOLDER: Name: Address: Citv: Zip: Phone: State Not Applicable MORTGAGE COMPANY: Name: Address: Citv: Zip: Phone:. BONDING COMPANY: Name: Address: City: Zip: Phone: Not Applicable State: Not Applicable OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorneybth re commencing work or recording your Notice of Cormencement. Signature of Owner/ STATE OF FLORIDA COUNTY OF13ROWARD as Agent for Owner Sworn to (or affirmed) and subscribed before me of X Physical Presence or Online Notarization this 26 day of MAY 2020 by MICHAEL FORGIONE Name of person making statement. Personally Known X OR Produced Identification Type of Identification Produced Signature of Contract Llc nse older STATE OF FLORIDA COUNTY OF13ROWARD Sworn to (or affirmed) and subscribed before me of X Physical Presence or Online Notarization this 26 day of MAY . 2020 by MICHAEL FORGIONE Name of person making statement. Personally Known x OR Produced Identification Type of Identification Produced (Signature of Notary Public- State of Florida }~ PRANCES EL•LEN Rl (Sig Notary Public - State ai = larira GG 350789 Commission ry GG .37, -89 Commission No. (Seal) f,tiy Corun. Expires Oct , CW Ecnded thrcuc;h National sat i y Assn. tore of Notary Public f'of-4 2W A ^; r_LFN ZARICK r,: i:: Stete of Florida ission No. GG 350789 (sea{ i, !I GG 350789 Expires Oct 4, 2023 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED ncv. �Jfvlcv Certificate of Product Ratinas AHRI Certified Reference Number: 204284142 Date : 05-26-2021 Model Status : Active AHRI Type: SPY -A (Year -Round Single -Package Air -Conditioner, Air -Cooled) Outdoor Unit Brand Name: RHEEM Outdoor Unit Model Number (Condenser or Single Package) : RACA14048BJT*—AA Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this RHEEM product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third parry testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 44500 SEER: 14.00 EER (A2) - Single or High Stage (95F) : 11.00 t°Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still sell[ng or offering for sale. Ratings that are accarnpanied by WAS indicate an involuntary re -rate. The new nublished ratino is shown along with the orevicus Ea. WAS1 ratino. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall onty be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's Individual, personal and confidential reference. AIR-CONDITIONING, neATINo, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which Is listed at bottom right. 02021 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132665116103207288 ENGINEERING J July 16, 2020 Product Approval Administrator DBPR Codes and Standards 2601 Blair Stone Road Tallahassee, FL 32399 Regarding: Rheem Manufacturing Company, Inc. Rheem Packaged Units EX #20-28788 To Whom It May Concern: This office has reviewed test reports showing static wind loading of the above -noted product. These test reports pertain to testing performed in accordance with ASTM E330-05, Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. This standard is not adopted in the Florida Building Code Seventh Edition (2020) but is equivalent to ASTM E330-02, which is an adopted standard in the Florida Building Code Seventh Edition (2020). Respectfully, SENrf'� 9 UI: 5CRTtiOF tl FLOR?pP • % Frank Bennardo, PE ENGINEERING EXPRESS® #PE0046549 I Cert. Auth. 9885 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 (954) 354-0660 1 (866) 396-9999 TEAM@ ENGINEERING EXPRESS. COM ENGINEERINGEXPRESS.COM WMV ENGINEERING Technical Evaluation Report DIVISION: 23 08 00—COMMISSIONING OF HVAC 160 SW 12TH AVE SUITE 106, DEERFIELD BEACH, FL 33442 (954) 354-0660 1 ENGINEERING EXPRESS.COM REPORT HOLDER: RHEEM MANUFACTURING COMPANY, INC. 1100 ABERNATHY ROAD SUITE 1400 + + ATLANTA, GA, USA 770-351-3000 1 RHEEM.COM SCOPE OF EVALUATION (compliance with the following codes): THIS IS A STRUCTURAL (WIND) PERFORMANCE EVALUATION ONLY. NO ELECTRICAL OR COOLING PERFORMANCE RATINGS OR CERTIFICATIONS ARE OFFERED OR IMPLIED HEREIN. This Product Evaluation Report is being issued in accordance with the requirements of the 71 Edition Florida Building Code (2020) per FBC Section 104.11, FMC 301.15, FBC Building Ch. 16, ASCE-7-16, FBC Building 1522.2, FBC Residential M1202.1, M1301.1, & FS 471.025. The product noted on this report has been tested and evaluated as summarized herein. SUBSTANTIATING DATA: • Product Evaluation Documents Test Reports Substantiating documentation has been submitted to provide this TER and is summarized in the sections below. Test Report: 0320.01-18 (American Test Lab of South FL) • Structural Engineering Calculations Structural engineering calculations have been prepared which evaluate the product based on comparative and/or rational analysis to qualify the following design criteria: Maximum allowable uplift, sliding, & overturning moment for ground and roof applications Maximum unit anchorage to steel curb NOTE: No 33% increase in allowable stress has been used in the design of this product. INSTALLATION: The product(s) listed above shall be installed in strict compliance with this product evaluation & manufacturer -provided model specifications. The product components shall be of the material specified in the manufacturer -provided product specifications. All screws must be installed in accordance with the applicable provisions & anchor manufacturer's published installation instructions. LIMITATIONS & CONDITIONS OF USE: Use of this product shall be in strict accordance with this product evaluation as noted herein. The supporting host structure shall be designed to resist all superimposed loads as determined by others on a site -specific basis as may be required by the Authority Having Jurisdiction. Host structure conditions which are not accounted for in this product's respective anchor schedule shall be designed for on a site -specific basis by a registered professional engineer. No evaluation is offered for the host supporting structure by use of this document; Adjustment factors noted herein and the applicable codes must be considered, where applicable. All supporting components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times. Fasteners must penetrate the supporting members such that the full length of the threaded portion is embedded within the main member. This evaluation does not offer any evaluation to meet large missile impact debris requirements which typically are not required forthis type of product. FL 26981.1 THIS DOCUMENT CONTAINS (4) PAGES NOTE: GRAPHICAL DEPICTIONS IN THIS REPORT ARE FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER IN APPEARANCE UNIT CASING MATERIAL: 20ga galv. sheet steel ASTM A653 Type B. Removable Top & side covers secured with #10 Sheet metal Hex Head Screws Knockouts provided for utility & control connections. FINISH: Baked Enamel INSTALLATION: Shall follow manufacturer specifications as well as information provided herein OPTIONS: This evaluation is valid for models shown in the last page STRUCTURAL PERFORMANCE: Models referenced herein are subject to the following design limitations: Maximum Rated Wind Pressure: 200psf Lateral 133psf Uplift VISIT ECALC.10/28788 � e [oil R1 FOR SITE SPECIFIC DEVIATIONS & MORE INFORMATION ABOUT THIS DOCUMENT OR SCAN THIS QR CODE VISIT ENCINEERINGEXPRESS.COMISTORE FOR ■ ADDITIONAL PLANS, REPORTS & RESOURCES NMI ENGINEER SIGNATURE AND SEAL: Digitally signed by x_ Frank Bennardo Date: 2020.08.13 „; 21:28:15-04'00' Frank Bennardo, P.E. ENGINEERING EXPRESS® FL PE #0046549 FLCA #9885 RHEEM PACKAGED UNITS Engineering < <<.;_:=� TER-20-28788 SECTION 2 PRODUCT INSTALLATION GROUND MOUNT APPLICATIONS CONFIGURATION A Note: Design & installation of ground host is by others per site specific conditions Opposite side similar ANCHOR SCHEDULE TO HOST STRUCTURE Pressure Steel Curb Steel Curb Lateral (Uplift) Concrete (psf) With Clip Screw Ground A Up to 81(64) C Up to 200 (133) B A. — 5/16" DEWALT ULTRACON Anchor embedded 2" in 3,515 psi concrete. 3 1/8" from edge minimum & 5" spacing minimum. NOA No. 17-1227.22 B. —#12 TEK Screws, (14) screws per clip, (5) top front side, (4) top back side and (5) bottom front side. C. — 3/8" SAE Grade 5 Self -Drilling Screw at 6" O.C, (15) per long side and (10) per short side. Ground structure substrate (concrete) TIE -DOWN CLIP (GROUND APPLICATION) Miami Tech CUTD 1" wide ASTM A653 galvanized steel 0.07" thick of varying length (FL19731.2) or equivalent for all cabinets tied down to a ground structure; fasten clip to structure using anchor from Anchor Schedule A to Host Structure Table and (3) #12 SAE Gr 2 self -drilling screw to fasten clip to unit base rail. Install in unit with quantities shown ((3) per side). Locate clips at 8.5" min away from the appropriate corner using three clips per side and three clips opposite side in the same configuration. STEEL CURB (ROOF APPLICATION) Steel curb to be a minimum of 16ga ASTM A653 steel Curb Clip to be 14ga ASTM A653 steel min (Microhold) CURB MOUNT APPLICATIONS CONFIGURATION B Note: Design & installation of curb to host by others per site specific conditions i° diameter holes L, J —L .,03 Curb Clip A MICROHOLDS Curb Clip C )HOLDS L,—J Curb Clip B IN ALL CONDITIONS IT IS THE RESPONSIBILITY OF THE PERMIT HOLDER TO ENSURE THE HOST STRUCTURE IS CAPABLE OF WITHSTANDING FORCES BY SITE -SPECIFIC DESIGN. NO WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, IS OFFERED BY RHEEM MANUFACTURING COMPANY, OR ENGINEERING EXPRESS AS TO THE INTEGRITY OF THE HOST STRUCTURE TO CARRY LOADS INCURRED BY THIS UNIT. CORP OFC: 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 2of5 (QS4) 354-06601(866) 3O6-OOQGIENE.INGGIAINGEuPRGGC.FAMITF6Mi6�ENAINFFf?INC.EaEnwFaa.FAM RHEEM PACKAGED UNITS Engineering =_1-1-s ::1:�_ I TER-20-28788 CURB CLIP LOCATION Clip B Clip C 012 TE SCREE a 1.375 - DETAIL A Table 1: Clip Curb Schedule Unit Model Number of Clips (PCs) (-)GEC - 036 (-)ACC - 036 ()HPC - 036 4 LS - 2 SS (-)GEC - 048 (-)ACC - 048 (-)HPC - 048 4 LS - 2 SS (-)GEC - 060 (-)ACC - 060 (-)HPC - 060 4 LS - 2 SS (-)GEC - 072 (-)ACC - 072 (-)HPC - 072 4 LS - 2 SS (-)GED - 090 (-)ACD - 090 (-)HPD - 090 5 LS - 3 SS (-)GED -102 (-)ACD - 102 (-)HPD - 102 5 LS - 3 SS (-)GED -120 (-)ACD - 120 (-)HPD -120 5 LS - 3 SS (-)GED - 150 (-)ACD - 150 5 LS - 3 SS #Clip Designation (5 LS= 5 clips each Long Side; ALTERNATIVE ANCHORAGE TO CURB 3 SS= 3 clips each Short Side) equally spaced STEEL CURB WITH SCREW CONFIGURATION C Mechanical Unit Curb Mounted DETAIL A: Applies for all clips and anchors type B RGEDZR —150 Clip Clip A Configuration: (5) clips to each long side, 3" away from corners, spaced at 5.22". (3) clips to each short side, 3" away from corners. Spaced at 5.50" Clip B See note (3) page (4) Unit Model Note:'(-)' designates equivalent trade brands with similar cabinetry and may vary depending on brand See pressures on page (2) for alternative anchor limitations MECHANICAL — UNIT INSTALLER TO ENSURE THAT THREADED PORTION UNIT BASE ENGAGES STEEL RAIL CURB BEYOND WOOD NAILER WITH MINIMUM ANCHOR (5) PITCHES PAST THE TYPE C THREAD PLANE i WOOD NAILER INSULATION (BY OTHERS) DETAIL B 16ga MICROMETL CURB DETAIL B CORP OFC: 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 3of5 (954) 354-0660I(866) 396-9999IENGINEERINGEXPRESS.COMITEAM(@ENGINEERINGEXPRESS. COM RHEEM PACKAGED UNITS Engineering t; :3__- " TER-20-28788 SECTION 3 MODELS SUMMARY, DIMENSION & NOTES TABLE 2: Qualified Tested Unit Construction Metal Cabinetry Unit Model Operating Dimensions w/ screw heads Operating Weight (Ibs) Width (in) Length (in) Height (in) RGEDZR-150 59 1/2 90 1/10 59 7/10 1070 TESTED UNIT LIMITATIONS 1. The unit model listed above was tested and designed as worst -case configurations of model units listed in Evaluation Model Series Matrix, remaining unit models are certified by this approval as long as they have identical construction as those listed above and are of equal or lesser dimensions (length, width, height). 2. Dimensions shown are measured from outermost points of unit, including screw heads. 3. Curb clips shall be as close as possible from the shown locations; installers shall verify any interference between clip attachment and internal components of the unit and move clip within the tolerance allowed. TABLE 3: Evaluation Model Serels Matrix (Unit Construction Metal Cabinetry) Unit Model Dlmenslons w/ screw heads Operating Weight (Ibs) —Operating Width (in) Length (in) Hei ht (In) (-)ACC - 036 46 3/4 78 3/8 41 3/8 453 (-)ACC - 048 46 3/4 78 3/8 41 3/8 477 (-)ACC - 060 46 3/4 78 3/8 41 3/8 482 (-)ACC-072 46 3/4 78 3/8 41 3/8 689 (-)ACD - 090 59 15/32 89 5/16 49 1/4 722 (-)ACD -102 59 15/32 89 5/16 49 1/4 748 (-)ACD -120 59 15/32 89 5/16 49 1/4 777 (-)ACD -150 1 59 1/2 90 1/10 59 7/10 946 REQUIRED WIND PRESSURES Design pressures calculated for use with these units shall be determined by others on a job -specific basis in accordance with the governing code. Site specific load requirements for wind load shall be determined in accordance with ASCE 7 and the codes referenced herein by separate engineering certification and shall be less or equal to design pressures capacity values listed herein for any assembly as shown. TEST REPORTS UTILIZED Design and certification of the unit cabinetry is approved through American Test Lab of South Florida Report #: 0320.01-18 Tested according ASTM E330-05 and TAS 202-94. TABLE 3.1: Evaluation Model Serels Matrix Unit Construction Metal Cabinetr ) Unit Model Operating Dimensions w/ screw heads Operating Weight Ibs Width (in) Length (in) Height (in) (-)GEC - 036 46 3/4 78 3/8 41 3/8 453 (-)GEC - 048 46 3/4 78 3/8 41 3/8 477 (-)GEC - 060 46 3/4 78 3/8 41 3/8 482 (-)GEC - 072 46 3/4 78 3/8 41 3/8 689 (-)GED - 090 59 15/32 89 5/16 49 1/4 846 (-)GED -102 1 59 15/32 89 5/16 49 1/4 872 (-)GED -120 1 59 15/32 89 5/16 49 1/4 901 TABLE 3.2: Evaluation Model Series Matrix (Unit Construction Metal Cabinetry) Unit Model Operating Dimensionsw/ screw heads Operating Weight (Ibs) Width (in) Length (in) Height (in) (-)HPC - 036 7B 3/8 46 3/4 41 3/8 528 (-)HPC - 048 78 3/8 46 3/4 41 318 551 (-)HPC - 060 78 3/8 46 3/4 41 3/8 553 (-)HPC - 072 78 3/8 46 314 41 3/8 1 553 (-)HPD - 090 1 89 5/16 1 59 112 1 49 1/4 786 (-)HPD -102 89 5/16 59 1/2 1 49 1/4 822 (-)HPD - 120 89 5/16 59 1/2 1 59 7/10 874 Unit Model Note: '(-)'designates equivalent trade brands with similar cabinetry and may vary depending on brand CORP OFC: 160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 4of5 (954) 354-06601(866) 396-99991ENGINEERING EXPRESS.COMITEAM�iOENGINEERINGEXPRESS. COM RHEEM PACKAGED UNITS Engineering I TER-20-28788 UNIT VIEWS 8 ELEVATIONS • — LEHGnI TOP VIEW ELEVATION VIEW Fig 09W -! SIDE VIEW 1M { f WIDTH - Note: RGEDZR-150 illustration selected for dimensional purposes —q CORP OFC: 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 Page 5of5 (954) 354-06601(866) 396-99991ENGINEERING EXPRESS.COMITEAM@ENGINEERING EXPRESS.COM Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 3216 Perigrine Falcon DR Sec/Town/Range: 24/36S/40E Parcel ID: 3424-800-0019-000-3 Jurisdiction: Saint Lucie County Ownership Carol D Griemsman 3216 Perigrine Falcon Dr Port St Lucie, FL 34952 Legal Description FAIRWAYS AT SAVANNA CLUB REPLAT NO. 1 (PB 57-40) BLK 66 LOT 5 (OR 2452-384) Current Values Just/Market Value: Assessed Value: Exemptions: Taxable Value: $134,500 $91,357 $50,000 $41,357 Property taxes are subject to change upon change of ownership. • Past taxes are not a reliable projection of future taxes. • The sale of a property will prompt the removal of all exemptions, assessment caps, and special classifications. Taxes for this parcel: SLC Tax Collector's Office 12 Download TRIM for this parcel: Download PDF 12 Use Type: 0200 Account #: 162058 Map ID: 34/24S Zoning: Planned Un Total Areas Finished/UnderAir (SF): 2,064 Gross Sketched Area (SF): 2,980 Land Size (acres): 0.17 Land Size (SF): 7,226 Building Design Wind Speed Occupancy Category I 11 III & IV Speed 140 160 170 Sources/links: All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2021 Saint Lucie County Property Appraiser. All rights reserved. � State License # ~ UNIVERSAL Carol Griemsman 4 [ R & HEAT— 3216 Perigrine Falcon Dr Port St. Lucie, FL 34952 Brand: Rheem cube r410a Size:: Depth: N/A Width: N/A Height: N/A Size:: Depth: N/A Width: N/A Height: N/A Electrical:: Breaker: N/A Heater: 10 1 Electrical :: Breaker: N/A SEER: 14 1 Digital Thermostat 1 Strap, Tape, Mesh, Mastic Supply & Return Connections To Ensure No Air Leaks 1 Mediclean Microbial Treatment (Value $399.00 Per HVAC Zone) 1 Sheet Metal Dog House Covering Supply & Return Ducts 1 Main Breaker For Package Unit 2 Locking Caps For Freon Valves 4 Hurricane Tie Downs ( up to code ) 4 Vibration Isolator Pads Under The Package Unit Hooked Up To Property owners Existing T-stat, Electrical, stand, slab & Duct Work ( unless otherwise noted for replacement on this invoice/estimate) ( If unit is located on the roof the Property owner will be Responsible To Hire Roofer if needed ) 1 Year Labor Warranty 10 year factory parts in unit warranty Clean Up Job site & Legal Disposal Of Old HVAC Equipment Properly Level Unit Sealed Equipment Connections Sub Cooled/Superheat Refrigerant Charging * Any Electrical Upgrades Are The Property Owners Responsibility *50% Deposit Is Due Upon Arrival Of Installation And Balance is Due as payment in full Upon Ac startup * * Price Is Only Valid For 30 Days * 1 Mechanical permits are not induced in this price and must be paid separately. We do not mark up the cost of the city permit fee. This fee can be paid directly to the city. Customer Technician Carol Griemsman Ref #: 209986 Customer Order 209986 SUB -TOTAL $5,952.65 INSTANT REBATE $892.90 - UTILITY REBATE - MANUFACTURE REBATE - DEPOSIT TRIP CHARGE TOTAL AMOUNT DUE $5,059.75 217 Customer Order �Nl State License # Carol Griemsman 209986 ERSAL Southeast Florida 3216 Perigrine Falcon Dr A I R &HEAT — Port St. Lucie, FL 34952 �4n rrn► 1 V Estimate We Propose To Furnish And Install A New 4 Ton 14 SEER Rheem cube r410a. Options: Choose from one of 10 payment options. Option #1 Cash,Check or Credit Card Price Before Rebates: $5,952.65 - Instant Rebate $892.90 Total Cost $5,059.75. Cash, Check or Credit Card Option #2 Wells Fargo Financing Price Before Rebates: $5,952.65 - Instant Rebate $714.32 Total Cost $5,238.33. 0% Interest if paid in full within 6 months Option #3 Synchrony Financing Price Before Rebates: $5,952.65 - Instant Rebate $357.16 Total Cost $5,595.49. 0% APR for 25 months with equal payments of about $223.82 with approved credit and terms. Option #4 Synchrony Financing Price Before Rebates: $5,952.65 - Instant Rebate $68.46 Total Cost $5,884.19. 0% APR for 36 months with equal payments of about $163.45 with approved credit and terms. Option #5 Synchrony Financing Price Before Rebates: $5,952.65 - Instant Rebate $59.53 Total Cost $5,893.12. 0% APR for 48 months with equal payments of about $122.77 with approved credit and terms. Option #6 Synchrony Financing Price Before Rebates: $5,952.65 Total Cost $5,952.65. 0% APR for 60 months with equal payments of about $99.21 with approved credit and terms. Option #7 Wells Fargo Financing Price Before Rebates: $5,952.65 Total Cost $5,952.65. 0% APR for 60 months with equal payments of about $99.21 with approved credit and terms. Option #8 Ygrene Financing Price Before Rebates: $5,952.65 - Instant Rebate $729.20 Total Cost $5,223.45. 7.49% APR for 120 months with equal payments of about $73.28 with approved credit and terms. This Option will be added to the yearly county property tax bill of about $879.36 per year. Option #9 Okinus Financing Price Before Rebates: $5,952.65 - Instant Rebate $595.27 Total Cost $5,357.38. Read Okinus Credit Solutions agreement for details. Text Okinus 6444 to 484848 and you'll receive an online application link to apply now. Option #10 Synchrony Financing Price Before Rebates: $5,952.65 - Instant Rebate $416.69 Total Cost $5,535.96. 9.99% APR for 132 months with equal payments of about $69.28 with approved credit and terms. Customer Technician Carol Griemsman Ref #: 209986 214 N,..titi���n,,,� Customer Order `. N State License # 209986 U_Nl ERSAL Carol Griemsman Al R & H EAT— 3216 Perigrine Falcon Dr Port St. Lucie, FL 34952 • MAKE ALL CHECKS PAYABLE TO UNIVERSAL AIR & HEAT • All Services performed under the warranty policy will be provided by Universal Air & Heat during normal Business Hours, Monday to Saturday. Business hours being 8:00 to 5:00 p.m., Monday through Friday 8:00 am to 5:00 p.m. Saturday. Warranty does not cover or include routine maintenance such as changing/cleaning filters, breaker tripping or replacing fuses. • It shall be at the discretion of Universal Air & Heat and its Technician to repair or replace defective parts, units or materials whenever is necessary. Any Nuisance calls beyond the scope of this agreement will be charged at our normal service rate and/or emergency rates. • Any alteration or deviation from the proposed specifications or conditions involving extra cost of materials or labor will only be executed upon the written order for the same and will become an extra charge over the sum mentioned in this contract. The terms and conditions set forth in this agreement are the only agreement between the parties, any inconsistent term or condition is not part of this agreement unless it is in writing and sighed by the customer and Universal Air & Heat. • Title to the equipment and other materials will remain with Universal Air & Heat until all sums due us have been paid in full. • All balances not paid within 30 days of the bill date will be subject to a monthly service charge in the amount of 1.50% of the outstanding balance. Customer is responsible for all cost of collection, including reasonable attorney's fees in the event of non - payment. In the event that any person/customer files suit against Universal Air & Heat if such case is found in favor of Universal Air & Heat customer will pay all cost including reasonable attorney's fees. • Customers acknowledges and understands that the cleaning of A/C ducts and registers may present a danger to any persons or animals in the job site due to the release of potentially dangerous airborne particles (including mold and dust). Customer is solely responsible to provide for the safety of all persons, pets and things at the job site. Customer is solely responsible for any harm suffered by any person therein. Customer agrees to hold Universal Air & Heat harmless and indemnify Universal Air & Heat for any damages related to the cleaning, removal or replacement of ducts, registers or other equipment. Universal warrants existing drain line hookups for 30 days with new equipment installed or serviced. Universal Air & Heat will use nitrogen to blow out drain lines and assumes no responsibility for water damage of any kind. Update 7/2/2016 Customer acknowledges, understands and is fully aware that new high efficiency HVAC 14 seer and above system's will require more frequent regular maintenance to any new or existing drain line and such maintenance is not included in this contract unless otherwise expressed in writing and agreed to by customer as well as a representative of Universal Air & Heat. Universal Air & Heat recommends flushing new or existing drain lines once every four months in efforts to achieve optimal performance and reduce the possibility of an accidental water loss occurring. Universal Air & Heat is not responsible for any water damage, wall painting, framing, and wall covering, equipment delay or any other inconvenience other than that of mechanical failure. Universal Air & Heat agrees to use reasonable efforts to run duct work within existing walls, ceilings and soffits. Customer acknowledges that the work performed may require the construction of soffits or other enclosures to conceal ductwork or other equipment and customer shall pay for all cost associated with the construction of same. • Universal Air & Heat has the right stop all work if payments as set forth herein are not made upon the due date. Once any equipment/materials have been delivered at the job site, it is the residential/Commercial property owner's or the General Contractor's responsibility to care for them. • Universal Air & Heat can and has the option to pick up any parts, equipment, units, etc., if payments as set forth herein are not made upon the due date from any and all properties, where such equipment, air conditioning units, and parts exist. • Any & All parts, equipment, supplies, etc., that have not been paid for shall remain the property of Universal Air & Heat until the balance is paid in full. • Upon acceptance this proposal sets forth the entire agreement of job between both parties. Warranty: • We warrant new air conditioning equipment for a period of one year ( unless otherwise stated in the description above and signed by a rep from Universal Air & heat ) from the date of installation that material and labor furnished by us will be free from defects. • Universal Air & Heat warrants that for 30 days from the date of any repair, all products will be free from defects in materials workmanship — except the air conditioner system compressor which is also warranted for 1 or 5 or 10 years on the part only subject to brands and models of the manufacturer. Copies of warranties are provided upon installation of new air conditioning equipment. • Under this warrant, Universal Air & Heat has the first option to repair the equipment or provide replacement parts. • THE LIABILITIES SET FORTH ABOVE ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES. EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY FOR PARTICULAR USE. Customer Technician Carol Griemsman Ref #: 209986 218