HomeMy WebLinkAboutLow Slope FormST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: CertainTeed
Product Approval No.:
20-0131.01
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': -45 Zone 1: -77 Zone 2: -102 Zone 3: -139
Max. Design Pressure, from the specific product approval
system: -52.5
Deck:
Type: Wood
Gauge Thickness:
Slope: 0/12 & 1/12
Anchor/Base Sheet & No. df Ply(s): Glasbase
Anchor/Base Sheet Fastener/Bonding Material:
Loose laid
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s): Flintastic SA Nailbase (1)
Base Sheet Fastener/Bonding Material:
Approved ringshank nails & tin caps
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Flintastic SA Cap
Top Ply Fastener/Bonding Material:
Self Adhere
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1': �o " oc @ Lap, # Rows
Zone 1:A— " oc @ Lap, # Rows 00 "
Zone 2:.�...." oc @ Lap, # Rows 5 ®0 "
Zone 3:�" oc @ Lap, # Rows .5 0 "
Number of Fasteners Per Insulation Board:
Zone 1': Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
rt,*J445k sA Ca.
x
2 �642, se
vJaad
FT.
Parapet
Height
FT.
to
Mean
Roof
Height