HomeMy WebLinkAboutDrawing0 enin
Size
1 :,:NOT COVERED :'
y -
,(ENTRYDOOR) -
;NOTCOVERED
Z. ACCORDIONS ` ;
300,x 07 ,
,:(LA'NAI)
3„ACCORDIONS?i',
, 1; 135z 88V?r�
.
r ,
F i F
F.
y
W
N
Z
W
W
W
M n
z N
0 a
z LU
2
� d
e,
J
d
WK
.Q]
VTT
VJ
CM
i �ILL
� zU
W
m m�
N ~
O
LL
NOT TO SCALE
ATE:
Apr 07, 2021
AGE DESCRIPTION:
Site Plan
AGE: OF1
1
Identification Schedule for Opening Protective Device or System
(The following minimum information shall be provided to facilitate plan review and inspection of the proposed installation, opening, protective device or system)
Address: 263 BIMINI DRIVE FORT PIERCE; FL 34949 Type of Structure: PERMIT #:
Dev.
#
Device
'type
Device
Manufacturer
Approval
Opening
Width
Opening
Height
Shutter
Width
Shutter
Height
# Storni
Bars Req.
Anchor
Spacing
Header
Reinf. Re
1.
NOT COVERED
NOT COVERED
No
2.
Accordion
Town & Country
FBC 13757
288
99
300
97
N/A
12"
No
3,.
Accordion
Town & Country
FBC 13757
128
90
135
88.5
N/A
1211/10
No
i
LEVINSON BUILT
13= ALL-AMERICAN STORM (DEFENSE
SHUTTIRS A GLASS
Property Information Building Infonnation
Owner: GILBERT, JIM Wind Zone: 170 MPH.
Address: 263 BIMINI DRIVE F Exposure' Category: B
FORT PIERCE, FL 34949 Minimum Building Dimension: 58 ft.
Mean Roof Height: 15 ft.
Risk Category: II J.
Design
Pressure Calculations
Opening
Number
Location
Zone IL
Device
—Width (in)
Device
Height (in)
Device
Elevation (ft) I
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1
Int
7
0.0
0.0
2
Int
300
97 7
25.0
-27.7
3
Int
135
88.5 7
26.9
-29.5
Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code.
Page 1 of 1