Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ROCHE SPECS
20/22/24 kW INCLUDES: • True Power'" Electrical Technology • Two-line multilingual digital LCD Evolution'" controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wi-Fi®connectivity • System status &maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 1 B in (457 mm) to a structure.' 'Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https; //assetsswri. org/librarylDirectoryOlListedProducts/ Constructian(ndustry/973_DoC 204_13204-01-01_Rev9.pdf FEATURES GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum -Bisque) - 20 kW 60 Hz G007042-2, G007043-2, G007042-3; 6 � - Aluminum -Bisque) - 22 kW 60 Hz G007209 , G007210=(i ( t{minum -Bisque) - 24 kW 60 Hz c \ 1 � us or CLISTEDUS VC �� n � k'� 0 Note: CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged vrith the Smart Switch are Eft or UL certitled in the USA only. O INNOVATIVE ENGINE DESIGN &RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREOUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible, Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mad - Force engine lineup offers added peace of mind and reliabiliy for when it's needed els. It provides optimized FAST RESPONSE to changing load conditions and MAXI - the most. The G-force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge rigors of extended run times in high temperatures and extreme operating conditions, loads to the engine. Digital voltage regulation at ±1 %. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network farm produce less than 5%Total Harmonic Distortion for utility quality power. This provides parts and service know-how far the entire unit, from the engine to the small - allows confident operation of sensitive electronic equipment and micro -chip based est electronic component. appliances, such as variable speed HVAG systems, O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous w(th ✓ PROTOTYPE TESTED ✓ NEMA MGi-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK° CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. O PWRVIEW'" TRANSFER SWITCH: The Generac PWRview Automatic Transfer Switch integrates the PWRview energy monitor to provide real-time energy con- sumption data that can help lower a home's electricity bill. Using a convenient mobile app, homeowners can access energy usage and alert information while under utility power or generator power. The PWRview energy monitor is a simple to use and low cost tool which helps save money over the life of the generator. Included with model G007210-0. ■ . � • ` � � � � ;ISO � �� t fs ENERAC® 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. PWRview Transfer Switch (if applicable) • PWRview energy monitor • Ability to view real-time energy consumption data • PWRview mobile app EvolutionT"' Controls • AUTO/MANUAUOFF illuminated buttons • Two-line multilingual LCD • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine coal -down • Programmable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Energy usage at -a -glance. Better understand the home's energy profile. Access daily energy intelligence and insights. Selects the operating mode and provides easy, at -a -glance status indication in any condition, Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Smooth, weather -resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to verify the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Verifies engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator far 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. 20/22/24 kW Features and Benefits Unit i SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. Installation System • 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. 0 Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month 's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. 20/22/24 kW Specifications Generator Model G007038-1 G007D42-2 G007038-0 G007042-0 GOD7209-0 G007039-1 G007043-2 G0070394 G007043�3 G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 I(W) Ratetlmaximumeontinuouspmver!citye(LP} 2O,OOtWatts 22OWattsti00WaKs 274(10WaDs* 2�O.VJatts — _ — Rated maximum continuous power opacity (NG) 18,000 Watts 19sou watts` i6,uuu watts£ ia,ouu vans n,uuu roans Ratedvoltage Rated maximum continuous load current - 240 volts (LP/NG) 83.3 / 75.0 91.7 / 81.3 83.3 / 75.0 91.7 / 81.3 100 / 87.5 Main line circuit breaker 90 amp 100 amp 90 amp 100 amp Number of rotor Doles 2 Power (actor 1.0 BaBe�requtrprnerd(n�rnctuiied) -, ,_ .. .� _ _4. - _. -_ 12Vblts Grarip�26H54�CCA�iginimurr�orGroup35AGkhfi60CCkrrtlnrrrurm ,j Unit weight (lb / kg) 448 / 203 466 / 211211 436 / 198 445 / 202 455 / 206 Sound output in d0(A) at 23 ft (7 m) with generator operating ai normal load" 67 67 67 67 67 Electronic 12VDC 3,600 Note: Fuel pipe must be sized for IuII load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG,1 D-12 in water column (2.49-2.99 kPa) for LP gas. For BTU content, multiply fhn/hr x 2500 (tP) or fta/hr x 1000 (NG). For Megajoule content, multiply m3Por x 93.15 (LP) or m3Por x 37.26 (NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. MANUAL Start with starter control, unit stays on. If utility falls, transfer to load takes place. to Run/Maintenance messages start delay between 2-1500 seconds Exerciser/Exercise Sei Smart Battery Charger Ci%argefEau(t/�fssingAC Low Battery/Battery Probl AutanraU�Volf�Regvif Under-Frequency/Overlo2 Safer FusedrEtue Profile Automatic Low Oil Press[ tivercranir/Ov_etspaeti (@ High Engine Temperature tntemat witAncorrecrW Common external fault o and 8attery Condition indication Overcurrent Protection Shutdown stanaara Standard `' Standard (programmable by dealer only) T EtarrT]At14�/ t9Q 276?u —Standard -:50 evet�eaptt _ rking:16 sec on, 7 rest (90 sec maximum iratre enga%LTe` untll �sec:afiterengme<ttas Standard ..y_ Siatitfatd't 77 -. Standard _ . Standaard - _z Standard Standa[d Standard v - SEapdard _.� Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may he higher depending on installation parameters. Rating definitions -Standby: Applioble for supplying emergency power for the duration of the utlity power outage. No overload opability is available for this rating. (AII ratings in accordance with &55514, IS03046 and DIN6271). 'Maximum Idlovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Ma>amum power decreases approximately 3.5%for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C). 20/22/24 kW Service Rated Automatic Transfer Switch Features • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of Ioad,100%equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMANL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Dimensions 200 Amps 12D/240,18 Open Transition Service Rated _ Height Width pepth H1 H2 Wi W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 PWRview Automatic Transfer Switch Features • Integrated PWRview monitor provides real-time energy usage data through PWRview app. • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of Ioad,100%equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 3R aluminum outdoor enclosure allows far indoor or outdoor mounting flexibility. ♦ Heavy duty 6enerac Contactor is an ETL recognized device. Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width Depth H1 H2 Wi W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 Model Current rating Utilityvoltage monitor (fixed)` -Pick-up Exercises hi -weekly for 5 minutes' Enclosure GENERAC� Switch Options G007039-1, G007039.3 (20 kW) G_007043 2 G007043-3 22 kW _ _ .(_ 200 �.�.._ .12D/24G„ifI � _. -. 80% 65% dppr�.a3sec• =� - � i Standard _ - Sfat_fiard` NEMANL3R Lug range 250 MCM - #6 *Function of Evolution controller Exercise can he set to weekly, bi-weekly, or monthly Model Current rating (amps) 200 Utility voltage monitor (fixed)' -Pick-up 80% -Dropout 65% Exercises bi-weekly for 5 minutes* Standard Enclosure type NEMA 3R Lug range 250 MCM - #6 *function of Evolution controller Exercise can be set to weekly, bl-weekly, or monthly I— w' —I "— v -=— w _- ,�_= ��� � 20/22/24 kW Model UPC G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 G007209-0 696471071511 G007210-0 696471078220 Available Accessories Dimensions & UPCs LEFT SIDE VIEW FRONT VIEW Oimensions shown are approbmate. See installaVon manual for exact dimensions. DO NOT USETHESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2020 Generac Power Systems, Inc. All rights reserved. All speciflcatlons are suhlect to change without notice. Part No. AOW0937814 Rev. 8 07/3012020