Loading...
HomeMy WebLinkAbout03-31-2021 Miriam Roche-Final04/27/2021 E-1 1 OF 2GENERATORADDITION RISERDIAGRAMNEW GENERATOR FOR:MIRIAM ROCHE2744 S. BROCKSMITH RD.FORT PIERCE, FL. 34945NTS 1 GENERATOR ADDITION RISER DIAGRAM DATEREVISIONMARKDATE: SHEET DATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911SCOPE OF WORK: ·REMOVE EXISTING GENERATOR AND ATS. ·INSTALL 200AMP SE RATED ATS IN SAME LOCATION AS OLD ATS THAT WAS REMOVED. RE-USE EXISTING CONDUIT FROM METER CAN TO ATS. INSTALL NEW CONDUCTORS. ·RE-FEED INTERIOR PANEL FROM NEW ATS. SEPARATE NEUTRALS AND GROUNDS IN PANEL IF REQUIRED. ·INSTALL COLD WATER BOND FROM ATS TO NEAREST CU WATER PIPING. ·UTILIZE EXISTING PAD FOR OLD GENERATOR. PLACE NEW GENERATOR ON EXISTING PAD. ·PROVIDE AND INSTALL (1) 24kW GENERAC GENERATOR. ·PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FROM ATS TO GENERATOR. USE SAME PATH AS OLD CONDUIT FROM ATS TO GENERATOR. ·PROVIDE (2) LOAD SHED DEVICES PER SIZING DATA THIS SHEET. ·GENERATOR GAS SUPPLY AND CONNECTION BY OTHERS UNDER A SEPARATE CONTRACT. ·NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPE OF WORK. GENERAL NOTES: 1. 2. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE. ELECTRICAL LEGEND: SURFACE MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD FLUSH MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD SURFACE MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD FLUSH MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD UTILITY METER CAN OR METER/MAIN COMBO UNIT GENERATOR AND GENERATOR PAD GAS STORAGE TANK SURFACE MOUNT AUTOMATIC TRANSFER SWITCH NON-FUSED DISCONNECT FUSED DISCONNECT 30AR NF 3R FRAME SIZE NEMA RATING NON FUSED 30AR 30AF 3R FRAME SIZE NEMA RATING FUSE SIZE CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION EXISTING 2"PVC UNDERGROUND SERVICE FEEDER EXISTING OVERHEAD SERVICE RISER, WEATHERHEAD, AND UTILITY FEEDERS EXISTING 1/2"PVC W/ (1) #4 BARE CU EXISTING 2"PVC W/ (3) #4/0 THWN AL 2"PVC W/ (3) #4/0 THWN AL, (1) #6 THHN CU GROUND 1-1/4"PVC SLEEVE W/ GENERAC CABLE W/ (3) #3 THHN CU, (1) #8 THHN CU GROUND, (5) #14THHN CU 1-1/4"PVC W/ (3) #3 THHN CU, (1) #8 THHN CU GROUND 3/4"PVC W/ (7) #14 THHN CU 1/2"PVC W/ (1) #4 BARE CU A B C D E F G H I POINT OF NEW CONNECTION AC ALTERNATING CURRENT A/C AIR CONDITIONING AFG ABOVE FINISHED GRADE AL ALUMINUM (CONDUCTOR) AHU AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AMP AMPERE AFCI ARC FAULT CIRCUIT INTERRUPTER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE C CONDUIT CU COPPER (CONDUCTOR) COVB CITY OF VERO BEACH DC DIRECT CURRENT DISC DISCONNECT EXIST EXISTING FPL FLORIDA POWER & LIGHT G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER IRC INDIAN RIVER COUNTY KVA KILOVOLT AMPERE KW KILOWATT MC METAL CLAD CABLE MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANELBOARD MTS MANUAL TRANSFER SWITCH MSB MAIN SWITCHBOARD MLO MAIN LUGS ONLY NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NTS NOT TO SCALE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NON-SE NON SERVICE ENTRANCE RATED PLCS PLACES (QUANTITY) PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT RMC RIGID METAL CONDUIT RTU ROOF TOP UNIT SE SERVICE ENTRANCE RATED TYP TYPICAL TEMP TEMPORARY TRANS, TX TRANSFORMER UG UNDERGROUND UL UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERE W WATT XFMR TRANSFORMER ABBREVIATIONS: NATURAL GAS METER NOTE: NOT ALL CONDUIT AND WIRE SHOWN ON THIS SCHEDULE MAY PERTAIN TO THIS PROJECT. (SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) GROUND ROD EXISTING 200 AMP METER CAN 120/240 1Ø NEW 200 AMP GENERAC SE RATED ATS 100AMP BREAKER EXISTING 200 AMP PANEL NEW GENERATOR: AIR COOLED GENERAC 24KW GRADE ATTIC ATTIC GRADE D E F INTERIOREXTERIOR INTERIOREXTERIOR EXTERIORINTERIOR EXTERIORINTERIOR FINISHED FLOOR EXISTING (2) 5/8" X 8' CU GROUND RODS C A LOAD MANAGEMENT "LCM" LOAD SHED LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENT AND FREQUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). GENERAL NOTES: ·THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. ·THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE NFPA 70 (2017). ·ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. ·THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NATIONAL ELECTRICAL CODE NFPA 70, ARTICLE 110.26 SPACES ABOUT ELECTRICAL EQUIPMENT. ·PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. ·ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. ·GROUNDING PER NATIONAL ELECTRICAL CODE NFPA 70, ARTICLE 250 GROUNDING AND BONDING. ·STANDBY SYSTEM INSTALLATION PER NATIONAL ELECTRICAL CODE NFPA 70, ARTICLE 702 OPTIONAL STANDBY SYSTEMS, AND MANUFACTURER INSTALLATION INSTRUCTIONS.F:\GENERATOR DRAWINGS\03-31-2021 Miriam Roche\03-31-2021 Miriam Roche.dwg, 4/27/2021 2:04:44 PM EXISTING UTILITY METER EXISTING PANEL NEW ATS NEW GENERATOR ON EXISTING PAD NEW UNDERGROUND GENERATOR FEEDER AND CONTROL CABLES NEW GENERATOR FEEDER AND CONTROL CABLES THROUGH ATTIC SINGLE FAMILYRESIDENCE2744 S. BROCKSMITH RD.FORT PIERCE, FL. 34945CONCRETE PAD SIDEWALK COVEREDPATIOCOVEREDPORCH10.0' UTILITY & DRAINAGE EASEMENT PROPERTY LINE 1240.14' 10.0' UTILITY & DRAINAGE EASEMENT PROPERTY LINE 1240.14'20.0' UTILITY & DRAINAGEEASEMENTPROPERTY LINE 329.66'60.0' UTILITY & DRAINAGEEASEMENTPROPERTY LINE 329.66'S. BROCKSMITH RD.04/27/2021 2 OF 2GENERATORSITE PLANS &PAD DETAILDATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 00019111" = 10'-0" 2 ENLARGED SITE PLAN DATEREVISIONMARKDATE: SHEET N W S E E-21/2" = 1'-0" 2 GENERATOR PAD DETAIL TOP VIEW LEFT ELEVATION FRONT ELEVATION DRILL DRILL 1/4" DEEPER THAN ANCHOR EMBEDMENT CLEAN DRIVE TIGHTEN 3-5 X DRILL BIT SIZE: 1/2"TIGHTENING TORQUE: 45ft.lbs. MIN. ANCHOR EMBEDMENT: 2-1/2" 1/4" MIN.54" 32" 6" MIN. 32"54" SPECIFIC NOTES: 28-01 REUSE EXISTING GENERATOR PAD FOR NEW GENERATOR. UTILIZE A NEW FORM AND POUR CONCRETE PAD IF EXISTING PAD IS UNABLE TO BE RE-USED DUE TO AGE OR CONDITION. NEW PVC CONDUIT FOR GEN CABLES TO TRAVERSE UNDER CONCRETE SIDEWALK AND FOLLOW OLD PVC CONDUIT PATHWAY. 28-XX NOTE: RE-USING EXISTING PAD FROM OLD GENERATOR. GENERATOR DETAIL IS FOR REFERENCE ONLY 0'3"6"1'2' SCALE: 1/2" = 1'-0" 0'2.5'5'10'20' SCALE: 1" = 10'-0" NOTE: 1.THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI STANDARD B212.15 IS RECOMMENDED. 2.ANCHOR BOLTS TO BE 3/8"DIA.x3-3/4"LONG UNLESS OTHERWISE NOTED.NEW GENERATOR FOR:MIRIAM ROCHE2744 S. BROCKSMITH RD.FORT PIERCE, FL. 349451" = 50'-0" 1 OVERALL SITE PLAN N W S E - 2 28-02 28-02 28-02 28-01 0'12.5'25'50'100' SCALE: 1" = 50'-0"F:\GENERATOR DRAWINGS\03-31-2021 Miriam Roche\03-31-2021 Miriam Roche.dwg, 4/27/2021 2:04:58 PM