HomeMy WebLinkAboutProduct Approval RECEIVED 7 1 aybd4 i +^ N11AM1 DADE,�,� PLAY2 4. 2021 M1AMI-DADE COUNTY i,1'.s •`_..e__.� RODUCT CONTROL SECTION Permitting DepartnientP DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) St. Lucie County 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION mi Florida 33175-2474 REF!1 � dia 2 (Di C(4886)315-2599 NOTICE OF ACCEPTANCE (NOA) CODE CMMM*tn�= GAF ST. LUCIE COUNTY 1 Campus Drive CC Parsippany,NJ 07054 SCOPE: /w This NOA is beingissued under the applicable rules and regulations governing the use of construction material�` �`P pp � g g The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). fle ConLtrol This NOA shall not be valid after the expiration date stated below. The Miami-Dade County P-rodi Section (in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Liberty7"SBS Self-Adhering Modified Bitumen Roofing Systems Over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 15-0203.05 and consists of pages 1 through 18. The submitted documentation was reviewed by Jorge L. Acebo. t NOA No.: 16-1206.02 Expiration Date: 02/22/22 MfAMf-DAD®CouNTY Approval Date: 02/16/17 �_ Pagel of 18 i J ROOFING SYSTEM APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -60 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Liberty" SBS Self-Adhering 39.375"x 66' ASTM D4601 Self-adhered, SBS modified base or Base/Ply Sheet ply sheet with glass reinforced mat. Liberty"MA Mechanically 39.375"x 66' ASTM D4601 SBS base sheet with a glass Attached Base Sheet reinforced mat coated with a polymer-modified asphalt. Liberty" SBS Self-Adhering 39.375"x 34' ASTM D6164 Granule surfaced self-adhering SBS Cap Sheet -- modified membrane reinforced with polyester mat, coated with polymer- modified asphalt. GAFGLAS®Ply 4 39.37" ASTM D2178 Type IV asphalt impregnated glass (1 meter)Wide felt with asphalt coating. Tri-Ply®Ply 4 39.37" ASTM D2178 Type IV asphalt impregnated glass (1 meter)Wide felt with asphalt coating. GAFGLAS®F1exPlyT", 6 39.37" ASTM D2178 Type VI asphalt impregnated glass (1 meter)Wide felt with asphalt coating. GAFGLAS®#75 Base Sheet 39.37" ASTM D4601 Type II, asphalt impregnated and (1 meter)Wide coated glass mat base sheet. Tri-Ply®#75 Base Sheet 39.37" ASTM D4601 Type II, asphalt impregnated and (1 meter)Wide coated glass mat base sheet. GAFGLAS®#80 Ultima7 Base 39.37" ASTM D4601 Type II, asphalt impregnated and Sheet (1 meter)Wide coated, fiberglass base sheet. GAFGLAS°Stratavento 39.37" ASTM D4897 A nailable, fiberglass base sheet Eliminator'Nailable Venting (1 meter)Wide coated on both sides with asphalt. Base Sheet Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Ruberoid® 39.37" ASTM D6163 SBS modified asphalt base sheet SBS Heat-Weld"25 (1 meter) Wide reinforced with a glass fiber mat and smooth surfaced. NOA No.: 16-1206.02 Expiration Date: 02/22/22 =IAMI•DADE coNE Approval Date: 02/16/17 Page 2 of 18 Test Product Product Dimensions Specification Description Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat coated with SBS Heat-Weld" Smooth (1 meter) Wide SBS polymer-modified asphalt and smooth surfaced. Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat coated with SBS Heat-Weld'" Granule (1 meter)Wide SBS polymer-modified asphalt and surfaced with mineral granules. Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat coated with SBS Heat-WeldT"' 170 FR (1 meter)Wide fire retardant SBS polymer-modified asphalt and surfaced with mineral granules. Ruberoid' 39.37" ASTM D6164 Non-woven polyester mat coated with SBS Heat-Weld"'Plus (1 meter)Wide SBS polymer-modified asphalt and surfaced with mineral granules. Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat coated with SBS Heat-Wel&'Plus FR (1 meter)Wide fire retardant SBS polymer-modified asphalt and surfaced with mineral granules. Ruberoid®EnergyCapT' SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Wel&"Plus FR (1 meter)Wide fire retardant SBS polymer-modified asphalt and surfaced with mineral granules with factory applied EnergyCoteT'. Ruberoid®Torch Smooth 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and smooth surfaced. Tri-Ply@ TP-4 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and smooth surfaced. Ruberoid®Torch Granule 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and surfaced with mineral granules. Tri-Ply®TP-4G 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and surfaced with mineral granules. Ruberoid®Torch FR 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter) Wide fire retardant APP modified asphalt surfaced with mineral granules. Ruberoid®EnergyCapT"Torch 39.37" ASTM D6222 APP modified cap membrane with a Plus FR (1 meter)Wide torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote' NOA No.: 16-1206.02 MIAMI•DADECOUNTY Expiration Date: 02/22/22 ® ,...® , Approval Date: 02/16/17 Page 3 of 18 Test Product Product Dimensions Specification Description Ruberoid®EnergyCap'Torch 39.37" ASTM D6222 APP modified cap membrane with a Granule FR (1 meter)Wide torch grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote" Ruberoid°20 39.37" ASTM D6163 SBS polymer-modified asphalt base (1 meter)Wide sheet reinforced with a glass fiber mat. Ruberoid°Mop Smooth 39.37" ASTM D6164 Non-woven polyester mat coated with (1 meter)Wide SBS polymer-modified asphalt and smooth surfaced. Ruberoid®Mop Smooth 1.5 39.37" ASTM D6164 Non-woven polyester mat coated with (1 meter)Wide SBS polymer-modified asphalt and smooth surfaced. Ruberoid®Mop Plus Smooth 39.37" ASTM D6164 Non-woven polyester mat coated with (1 meter)Wide SBS polymer-modified asphalt and smooth surfaced. GAFGLAS°Mineral Surfaced 39.37" ASTM D3909 Asphalt coated, glass fiber mat cap Cap Sheet (1 meter)Wide sheet surfaced with mineral granules. Tri-Ply®Mineral Surfaced 39.37" ASTM D3909 Asphalt coated,glass fiber mat cap Cap Sheet (1 meter)Wide sheet surfaced with mineral granules. GAFGLAS°EnergyCap' 39.37" ASTM D3909 Asphalt coated, glass fiber mat cap BUR Mineral Surfaced Cap (1 meter)Wide sheet surfaced with mineral granules Sheet and factory applied EnergyCote"'. VersaShield®Fire-Resistant 42" X 100' ASTM D 226 Non-Asphaltic fiberglass based Roof Deck Protection rolls underlayment and/or fire barrier. WeatherWatch®XT 36"x 50' rolls ASTM D1970 Mat surfaced SBS modified, 36"x 66.7' fiberglass reinforced,bituminous rolls sheet material used as a leak barrier underlayment. StormSafe'"Anchor Sheet 40"Wide ASTM D4601 Synthetic anchor sheet. Topcoat®Surface Seal SB 5 or 55 gallons ASTM D6083 Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. Topcoat®Membrane 1, 5 or 55 ASTM D6083 An acrylic,water based elastomeric gallons membrane system designed to protect various types of roof surfaces. Topcoat®MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer used to block asphalt bleed-through. NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DAD,COUNTY Approval Date: 02/16/17 Page 4 of 18 Test Product Product Dimensions Specification Description Topcoat®F1exSeal 1, 5 gallons or Proprietary Solvent based flashing compound for 1 qt. tube gutters and other detailing. Topcoat®FireOut"Fire 5 or 55 gallons ASTM D6083 Low VOC,water-based fire barrier Barrier Coating coating. APPROVED INSULATIONS: TABLE 2 Manufacturer Product Name Product Description (With Current NOA) EnergyGuard"'Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard:`RA Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard7 RH Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard'RN Polyiso Insulation Polyisocyanurate foam insulation GAF DensDeck®Roof Board Gypsum board Georgia-Pacific Gypsum LLC DensDeck®Prime®Roof Board Gypsum board Georgia-Pacific Gypsum LLC Securock' Gypsum-Fiber Roof Board Gypsum board United States Gypsum Corporation NOA No.: 16-1206.02 Expiration Date: 02/22/22 CIAMI•DADE COUNTY ® , Approval Date: 02/16/17 Page 5 of 18 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec'#12 Fastener Carbon steel fastener used Various GAF in steel or wood decks. 2. Drill-Tec"#14 Fastener Carbon steel fastener used Various GAF in steel,wood or concrete decks. 3. Drill-Tee"'ASAP®3S Drill-Tec'"#12 fastener Various GAF with Drill-Tec'" 3" Standard Steel Plate. 4. Drill-TecT'' Round galvalume plated 3" round GAF 3" Steel Plates steel stress plate with reinforced ribs for use with Drill-Tec"fasteners. 5. Drill-Tee'"' Round galvalume stress 3"round GAF 3" Standard Steel Plates plate used with Drill- Tee"'fasteners. 6. Drill-Tec17it AccuTrac® Galvalume steel plate for 3" x 3" GAF Recessed Plates use with Drill-TecT" fasteners. 7. Drill-Tec'AccuTrac® AZ-SS aluminized steel 3" x 3" GAF Flat Plates plate for use with Drill- Tee'#12 Fastener, Drill- Tee'#14 Fastener and Drill-Tec'XHD Fastener. 8. Annular Ring Shank Galvanized steel Nail: Minimum Generic Nails &Tin Caps Ring shank roofing nails 12 Ga. (Dade County Approved) with Galvanized steel tin Various lengths caps. Tin Caps: Minimum 32 Ga. 1%"Diameter NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DAD®COUNTY Approval Date: 02/16/17 low Page 6 of 18 EVIDENCE SUBMITTED: Test A2ency Name Report Identifier Date IRT-ARCON,Inc. TAS 114 02-005 01/18/02 TAS 114 02-014 03/22/02 UL LLC UL 790 R10689 03/14/13 UL 790 R1306 05/22/13 Factory Mutual Research Corp. 4470 3024805 11/20/06 4470 3036225 08/10/09 4470 3035140 08/10/09 4470 3040738 11/16/10 4470 3036980 08/14/09 4470 3044688 03/16/12 4470 3038278 11/18/11 4470 3032811 12/11/08 4470 797-03221-267 09/24/07 TrinitylERD ASTMD4897 G34140.04.11-5-R3 06/04/15 ASTM D4601 G 121110.12.08 12/02/08 ASTM D4601 G34140.04.11-4-R2 06/04/15 ASTM D6163 G34140.04.11-2 04/25/11 ASTM D6862 C8500SC.11.07 11/30/07 ASTM D6164 G33470.01.11 01/13/11 ASTM D6164 G31360.03.10 03/31/10 ASTM D6222 G43190.11.13-1 11/15/13 ASTM D6222 G43190.03.14-2 03/06/14 ASTM D6222 G43190.03.14-1 03/06/14 ASTM D6163 G40630.01.14-1 01/06/14 ASTM D6164 G40630.01.14-2A 01/07/14 ASTM D6164 G40630.01.14-2B-R1 01/16/15 ASTM D6164 G40630.01.14-2C 01/07/14 ASTM D6164 G46160.09.14-3B 09/09/14 ASTM D6164 G40630.03.14 03/06/14 ASTM D6164 G40630.01.14-2A-1-R1 04/10/14 ASTM D4601 G43180.01.14-1 01/10/14 ASTM D6164 G43180.03.14 03/03/14 ASTM D6164 G6850.08.08-R1 04/14/11 ASTM D6222 G6850.11.08 11/05/08 ASTM D6222 G6850.10.08 10/06/08 ASTM D3909 G43610.01.14 01/22/14 ASTM D3909 G30250.02.10-3-R2 06/03/15 ASTM D3909 SC6870.08.14-R1 09/04/14 ASTM D6222 G40620.07.12-2 07/17/12 ASTM D6163 G12210.06.09 08/03/09 ASTM D6222 G30250.02.10-2 05/11/10 Exterior Research and Design,LLC TAS 114 18035.12.02-2 12/24/02 TAS 114 01501.04.03 04/03/03 TAS 114 01516.04.06 04/20/06 TAS 114 G4280LAB.10.06 10/20/06 NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DADE COUNTY guififergill Approval Date: 02/16/17 Page 7 of 18 EVIDENCE SUBMITTED: (CONTINUED) Test Agency Test Name Report Identifier Date Atlantic&Caribbean Roof TAS 114 07-079 12/13/07 Consulting,LLC TAS 114 08-044 07/01/08 PRI Construction Material ASTM E96 GAF-306-02-01 07/07/11 Technologies LLC ASTM E2178 GAF-276-02-01 01/04/11 ASTM D2178 GAF-314-02-01 08/23/11 ASTM D2178 GAF-315-02-01 08/23/11 ASTM D226 GAF-270-02-02 11/15/10 ASTM D226 GAF-349-02-01 07/03/12 ASTM D1970 GAF-324-02-01 11/30/11 ASTM D6083 GAF-498-02-01 01/06/16 ASTM D6083 GAF-499-02-01 03/12/14 ASTM D6083 GAF-500-02-01 03/12/14 ASTM D6083 GAF-276-02-OIREV 01/03/11 ASTM C1289 GAF-369-02-01 10/22/12 ASTM C1289 GAF-464-02-01 02/06/14 TAS 139 GAF-671-02-01 06/30/16 TAS 114 GAF-434-02-03 09/06/13 Momentum Technologies Inc. ASTM D6162 AX04C9A 06/05/09 NOA No.: 16-1206.02 =IAMI oUNTY Expiration Date: 02/22/22 ,.. , , Approval Date: 02/16/17 Page 8 of 18 APPROVED ASSEMBLIES: Membrane Type: APP/SBS Deck Type 11: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached to supports max. 24" o.c. with 8d common nails max. 6"o.c. System Type A: All layers of insulation are adhered to a mechanically attached anchor sheet. Membrane fully or partially adhered. All General and System Limitations apply. Fire Barrier: Topcoat®FireOuf"Fire Barrier Coating,VersaShield®Fire-Resistant Roof (Optional) Deck Protection,DensDeck®Roof Board or Securock®Gypsum-Fiber Roof Board. Anchor sheet: GAFGLAS®Ply 4,Tri-Ply®Ply 4, GAFGLAS®FlexPlyT"6, GAFGLAS®#75 Base Sheet,Tri-Ply®#75 Base Sheet, GAFGLAS®#80 Ultima`"Base Sheet, GAFGLAS® Stratavent® Eliminator'Nailable Base Sheet,Ruberoid'20, Ruberoid®Mop Smooth, Ruberoid®Mop Smooth 1.5 or Ruberoid®Mop Plus Smooth mechanically fastened to deck with Miami Dade approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. in the 4" side lap and in two staggered rows in the field of the sheet. One or more layers of any of the following insulations. Base Insulation Layer(Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardT"Polyiso Insulation,EnergyGuardT"RA Polyiso Insulation, EnergyGuardT"RH Polyiso Insulation,EnergyGuard'"RN Polyiso Insulation Minimum 1"thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' DensDeck®Prime®Roof Board, Securock®Gypsum-Fiber Roof Board Minimum 1/4"thick N/A N/A Note: All layers of insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range at a rate of 20-40 lbs./100 sq. ft. or in 3/4" to 1" wide beads 6" o.c. of OlyBond 500'Adhesive or Olybond 500'Green applied in serpentine pattern with minimum 3/4"wide ribbons or OlyBond®Adhesive Fastener at a rate of 1 gal./100 ftz. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Ply Sheet: One or more layers of Liberty''' SBS Self-Adhering Base/Ply Sheet self-adhered (Optional) with minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Or One layer of WeatherWatch'XT self-adhered with minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Note: WeatherWatch®XT may only be used with a torch adhered cap. NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DADE COUNTY PP A roval Date: 02/16/17 •• ® , Page 9 of 18 Membrane: One layer of L'iberty`m SBS Self-Adhering Cap Sheet self-adhered with minimum 4"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. (Not for use with WeatherWatch®XT) OR" One or more layers of Ruberoid®SBS Heat-Weld`25, Ruberoid®SBS Heat- Weld" Smooth, Ruberoid® SBS Heat-Weld'Granule, Ruberoid® SBS Heat- Weld" 170 FR,Ruberoid® SBS Heat-Weld"Plus,Ruberoid®SBS Heat-Weld" Plus FR or Ruberoid®EnergyCap' SBS Heat-Weld""Plus FR heat welded to the self-adhering base/ply sheet in accordance with manufacturer's instructions. OR Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch Granule, Tri-Ply®TP- 4G, Ruberoid®Torch FR, RuberoieEnergyCap'Torch Plus FR or Ruberoid® EnergyCap'Torch Granule FR with minimum 3"wide laps and torch applied to the self-adhering base/ply in accordance with manufacturer's instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be listed in a current NOA Approval and applied in accordance with manufacturer's instructions. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCap'BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat®Membrane,Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. 4. Fibered Aluminum Roof Coatitjg., Maximum Design-- r- Pressure: y' -45 psf. (See General Limitation#7) NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DADE COUNTYM PP A roval Date: 02/16/17 •••• , Page 10 of 18 Membrane Type: APP/SBS Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32"plywood attached to supports max. 24"o.c. with 8d common nails max. 6"o.c. System Type C(1): Top layer of insulation is simultaneously mechanically attached with optional layer of base insulation to the deck. Membrane fully or partially adhered. All General and System Limitations apply. Fire Barrier: Topcoat®FireOut'Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck (Optional) Protection,DensDeck®Roof Board or Securock'Gypsum-Fiber Roof Board. One or more layers of any of the following insulations. Base Insulation Layer(Optional) Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard" Polyiso Insulation,EnergyGuard"RA Polyiso Insulation,EnergyGuard'"RH Polyiso Insulation,EnergyGuard" RN Polyiso Insulation Minimum 1"thick(Loose laid) N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuar&"Polyiso Insulation,EnergyGuard"RH Polyiso Insulation Minimum 1.5"thick 1 &4,5 1:2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One layer of Liberty'"' SBS Self-Adhering Base/Ply Sheet self-adhered with minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Or One layer of WeatherWatch®XT self-adhered with minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Note: WeatherWatch®XT may only be used with a torch adhered cap. Ply Sheet: One layer of Liberty'' SBS Self-Adhering Base/Ply Sheet self-adhered with (Optional) minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. (Not for use with WeatherWatch®XT) NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DADE COUNTY Approval Date: 02/16/17 Pagel 1 of 18 Membrane: One layer of LiburV' SBS Self-Adhering Cap Sheet self-adhered with minimum 4" wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. (Not for use with WeatherWatch®XT) OR One or more layers of Ruberoid® SBS Heat-Weld''25,Ruberoid® SBS Heat-Weld'' Smooth,Ruberoid® SBS Heat-Weld' Granule,Ruberoid®SBS Heat-Weld"" 170 FR, Ruberoid®SBS Heat-Weld'' Plus,Ruberoid® SBS Heat-Weld'Plus FR or Ruberoid®EnergyCapT' SBS Heat-Weld'•' Plus FR heat welded to the self-adhering base/ply sheet in accordance with manufacturer's instructions. OR Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch Granule, Tri-Ply®TP- 4G, Ruberoid®Torch FR,Ruberoid®EnergyCap"m Torch Plus FR or Ruberoid® EnergyCap'm Torch Granule FR with minimum 3"wide laps and torch applied to the self-adhering base/ply sheet in accordance with manufacturer's instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be listed in a current NOA Approval and applied in accordance with manufacturer's instructions. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCap'.BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat®Membrane,Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. 4. Fibered Aluminum Roof Coating. Maximum Design Pressure: -45 psf. (See General Limitation#7) NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DADE COUNTY Approval Date: 02/16/17 •••� PP Page 12 of 18 Membrane Type: APP/SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"plywood attached to supports max. 24"o.c. with 8d common nails max. 6" o.c. System Type C(2): Top layer of insulation is simultaneously mechanically attached with optional layer of base insulation to the deck. Membrane fully or partially adhered. All General and System Limitations apply. Fire Barrier: Topcoat®FireOut''Fire Barrier Coating,VersaShiele Fire-Resistant Roof Deck (Optional) Protection,DensDeck®Roof Board or Securoce Gypsum-Fiber Roof Board. One or more layers of any of the following insulations. Base Insulation Layer(Optional) Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard""Polyiso Insulation,EnergyGuard'"RA Polyiso Insulation,EnergyGuard"'RH Polyiso Insulation,EnergyGuard"'RN Polyiso Insulation (Loose laid) N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' Securock®Gypsum-Fiber Roof Board Minimum 1/2"thick 1 &4,5 1:2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One layer of Liberty' SBS Self-Adhering Base/Ply Sheet self-adhered in accordance with manufacturer's instructions. OR One layer of WeatherWatch®XT self-adhered with minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Note: WeatherWatch®XT may only be used with a torch adhered cap. Ply Sheet: One layer of Liberty'" SBS Self-Adhering Base/Ply Sheet self-adhered with (Optional) minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. (Not for use with WeatherWatch®XT) Membrane: One layer of Liberty'' SBS Self-Adhering Cap Sheet self-adhered with minimum 4" wide side laps and rolled with a weighted roller in accordance with manufacturer's instructions. (Not for use with WeatherWatch®XT) OR Ruberoid®Torch Smooth, Tri-Ply®TP-4,Ruberoid®Torch Granule, Tri-Ply,TP- 4G, Ruberoid®Torch FR, Ruberoid®EnergyCap''Torch Plus FR or Ruberoid® EnergyCap''Torch Granule FR with minimum 3"wide laps and torch applied to the self-adhering base/ply sheet in accordance with manufacturer's instructions. NOA No.: 16-1206.02 DE COUNTY Expiration Date: 02/22/22 MIAMbDA ...� , Approval Date: 02/16/17 Page 13 of 18 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be listed in a current NOA Approval and applied in accordance with manufacturer's instructions. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCap'm BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat®Membrane,Topcoat®MB Plus(to be used as a primer with Topcoat®Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. 4. Fibered Aluminum Roof Coating. Maximum Design Pressure: -52.5 psf. (See General Limitation#7) NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DAD®COUNTYIM Approval Date: 02/16/17 Page 14 of 18 System Type E(1): Base Sheet is mechanically attached to the deck. Membrane fully or partially adhered. All General and System Limitations shall apply. Fire Barrier: Topcoat®FireOut'' Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck (Optional) Protection,DensDeck®Roof Board or Securock"'Gypsum-Fiber Roof Board. Base Sheet: Lil erty'"' MA Mechanically Attached Base Sheet in accordance with manufacturer's instructions. Fastening Options: Base sheet is mechanically attached to the deck with Drill-Tec''#14 Fasteners and Drill-TecT"'3" Steel Plates 8"o.c. in the 3"laps and 8"o.c. in two staggered rows in the field. (Maximum Design Pressure—60 psf.,See General Limitation #7) Base sheet is mechanically attached to the deck with Miami Dade approved tin- caps and nails at 8" o.c. in the 3"laps and 8"o.c. in three equally spaced, staggered rows in the field of the sheet. (Maximum Design Pressure—45 psf.,See General Limitation #7) Ply Sheet: One or more layers of LibertyTm SBS Self-Adhering Base/Ply Sheet in accordance (Optional) with manufacturer's instructions. OR One layer of WeatherWatch®XT self-adhered with minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Note: WeatherWatch®XT may only be used with a torch adhered cap. Membrane: One layer of Liberty SBS Self-Adhering Cap Sheet self-adhered in accordance with manufacturer's instructions. (Not for use with WeatherWatch®XT) Or One or more layers of Ruberoid® SBS Heat-Weld'"25, Ruberoid® SBS Heat- Weld"' Smooth, Ruberoid®SBS Heat-Weld"'Granule,Ruberoid® SBS Heat- Wel&" 170 FR, Ruberoid®SBS Heat-Weld'Plus, Ruberoid® SBS Heat-Weld"' Plus FR or Ruberoid®EnergyCap'' SBS Heat-Weld'"Plus FR heat welded in accordance with manufacturer's instructions. OR Ruberoid®Torch Smooth, Tri-Ply®TP-4,Ruberoid®Torch Granule,Tri-Ply 'TP- 4G, Ruberoid®Torch FR,Ruberoid®EnergyCap'"Torch Plus FR or Ruberoid® EnergyCap''Torch Granule FR with minimum 3"wide laps and torch applied in accordance with manufacturer's instructions. NOA No.: 16-1206.02 Expiration Date: 02/22/22 T4RMUMIAMI•DADE COUNTY .., Approval Date: 02/16/17 Page 15 of 18 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be listed in a current NOA Approval and applied in accordance with manufacturer's instructions. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCap""BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. 3. Topcoat®Membrane,Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane) or Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. 4. Fibered Aluminum Roof Coating. Maximum Design Pressure: See fastening options above NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMI•DAD®couNTY Approval Date: 02/16/17 Page 16 of 18 Membrane Type: APP/SBS Deck Type 1: Wood,Non-insulated Deck Description: Min. 19/32" CDX plywood nailed to 6" o.c. at the field of the sheet with#8 ring shank nails and 4"o.c. at the perimeter of the sheet with#10 ring shank nails. Plywood installed over wood rafters spaced 24"o.c. System Type E(2): Base sheet is mechanically attached to the deck. Membrane fully or partially adhered. All General and System Limitations shall apply. Fire Barrier: Topcoat®FireOutT"Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck (Optional) Protection,DensDeck®Roof Board or Securock'Gypsum-Fiber Roof Board. Base Sheet: StormSafe''Anchor Sheet is fastened to the plywood deck using Drill-Tec'"#12 Fasteners and 3"Drill-Tec'Accutrac®Flat Plates or Drill-Tec'AccuTrac® Recessed Plates spaced 9"o.c. at the 4" side laps and 3 rows spaced 9"o.c. in the field of the sheet. Ply Sheet: One layer of Liberty'" SBS Self-Adhering Base/Ply Sheet self-adhered with (Optional) minimum 3"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Membrane: One layer of Liberty`' SBS Self-Adhering Cap Sheet self-adhered with minimum 4"wide laps and rolled with a weighted roller in accordance with manufacturer's instructions. Or One or more layers of Ruberoid® SBS Heat-Weld'25,Ruberoid® SBS Heat-Weld"' Smooth, Ruberoid®SBS Heat-Weld"Granule,Ruberoid®SBS Heat-Weld' 170 FR, Ruberoid® SBS Heat-Weld''Plus,Ruberoid® SBS Heat-Weld'Plus FR or Ruberoid®EnergyCap' SBS Heat-Weld"Plus FR heat welded in accordance with manufacturer's instructions. OR Ruberoid®Torch Smooth,Tri-Ply®TP-4, Ruberoid®Torch Granule,Tri-Ply®TP- 4G,Ruberoid®Torch FR,Ruberoid®EnergyCap'Torch Plus FR or Ruberoid® EnergyCap'Torch Granule FR with minimum 3"wide laps and torch applied in accordance with manufacturer's instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be listed in a current NOA Approval and applied in accordance with manufacturer's instructions. 1. Gravel or slag applied at 4001bs./sq. and 3001bs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCap'BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat®Membrane,Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane) or Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. 4. Fibered Aluminum Roof Coating. Maximum Design -Pressure: -60 psf. (See General Limitation#7) NOA No.: 16-1206.02 9 MIAMI-DADExpiration Date: 02/22/22 MIAM{•DA (Q COUNTY Approval Date: 02/16/17 Page 17 of 18 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with GAFGLAS®Ply 4, Tri-Ply®Ply 4 and GAFGLAS®FlexPly 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: l. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq.,or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,prepared, signed and sealed by a Florida Registered Engineer,Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.Calculations prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered Roof Consultant(When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e.perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 16-1206.02 Expiration Date: 02/22/22 MIAMIMO COUNTY Approval Date: 02/16/17 Page 18 of 18