HomeMy WebLinkAboutProduct Approval (3) r � C
cr'.
® - ui-M, h; -0
Business&-,� .
R- EIWEVVELI FOR
COMPLIAN
BC15 Home ; Log In User Registration Hot Topics i S mi ur arge Stats&Fa P 1 natig tt Us BCIS Site Map Links Search ;
Florida T® L I �
Product Approval 30
¢
ii USER:Public User
loll
ta*:"rstKS::
product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL30343-112
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Premier Metal
Address/Phone/Email 17613 South Hwy.475
Summerfleld,FL 34491
(352)356-1609
ffvalidation@yahoo.com
Authorized Signature Ray Bowen
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 08/03/2022
Validated By James R Wally,PE
J Validation Checklist-Hardcopy Received
Certificate of Independence FL30343 R2 COI 26oa SVCrimo plywood. df
Referenced Standard and Year(of Standard) Standard Year
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
� a
Product Approval Method Method 1 Option D
Date Submitted 10/21/2020
Date Validated 10/25/2020
Date Pending FBC Approval
Date Approved 10/28/2020
Summary of Products
FL# Model,Number or Name Description
30343.1 (01: 26ga 5V Crimp over plywood 26ga(min)5V Crimp over 15/32"(min)plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 26ga SVCrimp plywood.pdf
Approved for use outside HVHZ:Yes Verified By:David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-108.5 Evaluation Reports
Other:108.5psf with 12"-12"pattern at 12"oc FL30343 R2 AE 26ga 5VCrimp plywood.pdf
Created by Independent Third Party:Yes
30343.2 02: 26ga PermaShield over plywood 26ga(min) PermaShield screw strip over 15/32"(min)plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 26ga PermaShield plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-116 Evaluation Reports
Other:116psf fastener every hole WITH sealant,71psf FL30343 R2 AE 26ga PermaShield plywood.pdf
fastener every other hole Created by Independent Third Party:Yes
30343.3 03: 032 Aluminum PermaShield over Nominally 032 or thicker aluminum PermaShield screw strip
plywood over 15/32"(min)plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 032AI PermaShield i lywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-153.5 Evaluation Reports
Other:153.5 with fastener every hole WITH sealant,86psf FL30343 R2 AE 032AI PermaShield plywood.pdf
with fastener every hole with OUT sealant. Created by Independent Third Party:Yes
30343.4 04:26ga TuffKb over plywood 26ga (min)TuffRib over 15/32"(min)plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 26ga TuffRib plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-123.5 Evaluation Reports
Other:123.5psf with 6.5"-2.5"-6.5"-2.5"fastener pattern @ FL30343 R2 AE 26ga TuffRib plywood.pdf
12"oc,82.25psf with 9"-9"-9"fastener pattern @ 24"oc Created by Independent Third Party:Yes
30343.5 05: 032 Aluminum DuraSeam over Nominally 0.032"or thicker aluminum DuraSeam over 15/32"
plywood (min)plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 032A1 DuraSeam of wood.ndf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-108.5 Evaluation Reports
Other:108.5 psf with clips @ 18"oc FL30343 R2 AE 032AI DuraSeam DI wood.odf
Created by Independent Third Party:Yes
30343.6 06:26ga DuraSeam over plywood 126ga(min)DuraSeam over 15/32"(min)plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 26ga DuraSeam plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-93.5 Evaluation Reports
Other:93.5psf with clips @ 12"oc,63.5psf with clips @ 16" FL30343 R2 AE 26ga DuraSeam pywgod.odf
oc Created by Independent Third Party:Yes
30343.7 07:29ga TuffRib over plywood 29ga(min)TuffRib over 15/32"(min)plywood I Fastener in the
rib
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 29ga TuffRib Plywood-rib.odf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-123.5 Evaluation Reports
Other:123.5 psf with 9"-9"-9"fastener pattern @ 12"oc, FL30343 R2 AE 29ga TuffRib Plywood-rib.pdf
56psf @ 24"oc Created by Independent Third Party:Yes
30343.8 08: 29ga TuffRib on 1x4 battens over�29ga.'min)TuffRib on lx4(nom)battens over 15/32"(min)
plywood d
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30343 R2 II 29ga Tuffft iX4.pdf
Approved for use outside HVHZ:Yes Verified By:David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-131 Evaluation Reports
Other:131 psf with 9"-9"-9"fastener pattern @ 12"oc, FL30343 R2 AE 29ga TuffRib IX4.pdf
78.5psf @ 24"oc Created by Independent Third Party:Yes
30343.9 09: 29ga TuffRib over plywood 29ga(min)TuffRib over 15/32"(min)plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL30341 R2 II 29ga TuffRib Plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant: N/A Created by Independent Third Patty:Yes
Design Pressure:+N/A/-93.5 Evaluation Reports
Other:93.5 psf with 9"-9"-9"fastener pattern @ 12"oc,56psf FL30343 R2 AE 29ga TuffRib Plywood.pdf
@ 24"oc Created by Independent Third Party:Yes
Buc1s Plaxt
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copvright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click ere.
Product Approval Accepts:
ON rCh[
Credit Card
Safe
PPPW
FL30343.01-R2
PG 1
r�
FLORIDA PRODUCT APPROVAL
26GA 5V Crimp over 15/32 Plywood
Premier Metal Roof Manufacturing
17613 S. Hwy 475 Summerfield FL 34491
www.PMRoof.com 352-356-1609 �.
Product Description 24" WIDE PANEL
5V style metal roof panel anchored by exposed fasteners. Panel "` Tv
coverage is nominally 24" with nominal rib height of 1/2"
Product Material: 26ga (min) steel -"
26ga is nominally 0.0185" with yield strength of at least 50ksi, and ? ; � ,
shall be corrosion resistant per FBC 1507.4.3 where required � ,'
Fastener: #10 x 1.5 inch fastener with sealing washer Classic Exposed Fastener Panel
Compliant with FBC 1506.6 where required.
Substrate/Deck: 15/32" (min) plywood
Maximum Allowable Loads & Installation Requirements:
Method A: #10 x 1.5" fastener in 12"-12 pattern at 12": 108.5 PSF
A factor of safety of 2 has been applied.
Evaluated by:
David Eng, PE I Timberlake Cove, LLC
3324 W Univ Ave#206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
David E Eng ;
—2020.10.18 No.81377 _
_-__.22:21:32+01'00'
This item has been digitally signed and ~ -) �-
sealed by D.E.Eng,PE,on the date ;0 - STATE OF ���
.indicated.Printed copies of this document
are not considered signed and sealed and
the signature must be verified on any
electronic copies
t�
���� PNfROORCOM
_-,--FL30343 01 R2
PG 2
Underlayment: Comply with local building code or FBC 1507.1.1.
Slope: Comply with local building code or FBC 1507.4.2.
Technical Documentation:
This product has been tested to UL 580 by Intertek Testing (TST-1527), report K9550.03-450-44.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-
HVHZ) as required by FL Rule 61 G20-3, method 1 D.
This product as described has been tested and demonstrated compliance with:
• UL580—Test for Uplift Resistance of Roof Assemblies
• UL 1897— Uplift test for roof covering systems
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The same entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure(to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation.
This report is limited to compliancer with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61 G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product.
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement for the
applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters,
design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force,
using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the
structure is:
• Enclosed and conforms to.wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location
for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific approval by local
authorities having jurisdiction.
_~ -FL30343.01-R2
PG 3
2 2 3
y I 2 1 1 2
•
lnstiructions: 2�-�
t
2 2 3
a
'Select the appropriate load table that applies to the structure In 2 1 2 2 3 -
x r- —1
question. 2
Determine the design wind speed for the project location. 2 1 1 2
Use the attachment method indicated for that windspeed within a 3 3 a
each roof zone. f- �
a HIP ROOF GABLE ROOF a L
NOTE:ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tattles `
below,the worst case was taken for each zone and reported using the standard a M.OF LEAST ROQONTAL OIAIENSION OR 04k IMCNEVER LS SL%LLER.BUT NOT
LESS THAN EITMER4%OF LEAST MORIZO19AL MIENSION OR 3"L02LI,
zones 1-2-3: ORASOETERIA1MDBTDESIONOROTMERAPPUCABLE000E
Zone 1 includes zones 1 and 1' ROOF ZONES FOR GENERIC.BUILDING
Zone 2 includes zones 2e,2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear,simple scheme,at the expense of some
design efficiency. Contact the manufacturer for further information, or consult a
licensed design professional.
NR: CONSULT DESIGN
METHOD A: 12" O.C. PROFESSIONAL
12" (NOM) 12" (NOM) -�
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof,or gablelhip roof with max slope of 12:12 Have either a flat roof,or gablelhip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL30343.01: 26 a 5V Crimp on 15/32" plywood FL30343.01: 26cia 5V Crimp on 15132" Plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A -
Zone 2: A A A A A A A A A A Zone 2: A A A A A - - R
Zone 3: A A A A A A A A l Zone 3: A A A A
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 1.5:12,hip roof with Have either a flat roof less than 1.5:12,hip roof with
max slope of 12:12,or gable roof with slope between 4.4:12 and 12:1 max slope of 12:12,or gable roof with slope between 4.4:12 and 12:1
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL30343.01: 26 a 5V Crimp on 15/32" Plywood FL30343.01: 26cia 5V Crimp on 15/32"plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A
Zone 3: A A A A A A A A A Zone 3: A A A A -A -
11111 PM ROOF.COM�