FL# FL20876-R2
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Dupont
Address/Phone/Email 5401 Jefferson Davis Highway
Richmond,VA 23234
(812)212-4429•
melissa.s.grant@dupont.com
Authorized Signature Melissa Grant
melissa.s.grant@dupont.com
Technical Representative Melissa Grant
Address/Phone/Email P.O. Box 103
202 E.Washington Street
Morris,IL 60450
(812)212-4429
melissa.s.grant@dupont.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity Intertek Testing Services NA,Inc.
Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Intertek Testing Services NA,Inc.
Certificate of Independence
Referenced Standard and Year(of Standard) Standard Year
ASTM D226 2009
Equivalence of Product Standards
Certified By
Sections from the Code
r A
Product Approval Method Method 1 Option C
Date Submitted 01/27/2021
Date Validated 01/27/2021
Date Pending FBC Approval
Date Approved 01/29/2021
Summary of Products
FL# Model,Number or Name Description
20876.1 Dupont Protec Underlayment 120,160,200
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL20876 R2 II K29385 Tyvek Protec Install Guide.pdf
Approved for use outside HVHZ:Yes Verified By:Intertek Testing Services NA,Inc.
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other: FL20876 R2 AE 2021-01-26 CCRR-1062.pdf
20876.2 Dupont Tyvek Underlayment Roof Protector
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL20876 R2 II SC00501 Tyvek Roof Protector Brochure.pdf
Approved for use outside HVHZ:Yes Verified By:Intertek Testing Services NA,Inc.
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other: FL20876 R2 AE 2021-01-26 CCRR-1087.pdf
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here...
Product Approval Accepts:
®® EChccV -ate
Credit Card
Sate
40UPONTk
Installation Information
Tyvek.
DuPont TM Tyvek° ProtecTm
Roofing Underlayments Installation Guidelines
SYSTEM OVERVIEW
Installation Guidelines Acceptable For Use With • Tyvek'Protec"meets or exceeds the following code
• DuPont"^Tyvek°Protec"120 criteria and test protocols:
• DuPont'Protec"'160 -AC188(Intertek CCRR-1062)
• DuPont'Tyvek'Protec'200 -ASTM D226 types I&II
Specifications -ASTM E108
• Tyvek`Protec'is available in 10 square rolls: -CAN/CSA A123.3
48"x25071.2m x 76.2m(92.9m2), -CAN/CSA A220.1
and 2 square rolls:48"x5071.2m x 15.2m(18.5 m2) Precautions and Safety
• Tyvek'Protec"is for use on roofs with slopes>_2:12. . Apply Tyvek'Protec"taut and wrinkle-free.
• Tyvek'Protec"must be covered with the final roof Do not stretch.
cladding within: • Do not apply Tyvek Protec"over wet or frost-covered
3-months with Tyvek'Protec"120 roof sheathing.
6-months with Tyvek*Protec"160 or Tyvek' • Caution should be taken when walking on Tyvek'
Protec'200 Protec"until it has been fastened according to
Tyvek'Protec-should not be considered a final roofing instructions.
system/primary water barrier.Tyvek'Protec-is a • Caution should be taken when walking on Tyvek'
secondary layer applied over sheathing,under a primary Protec"when it is wet or frost-covered.
roofing system as specified for the following: • Use fall protection when working on roof.Refer to
-Tyvek'Protec'120-asphalt shingles,metal or cedar OSHA safety regulations 29 CFR1926 subpart M.
roof cladding • Consult your local DuPont"Tyvek'Specialist for
additional information.
-Tyvek'Protec"160-asphalt shingles,tile,metal,
cedar,or slate roof cladding Preparation
-Tyvek'Protec"200-asphalt shingles,tile,metal, • Apply Tyvek'Protec"over a dry,smooth,clean and
defect-free roof deck.Tyvek Protec'cannot be installed
cedar,or slate roof cladding over existing roof cladding.
Building Code Compliance • Tyvek`Protec"is a vapor barrier.Ensure that the space
• Consult local building code and roof cladding beneath the roof sheathing is properly ventilated before
manufacturer for use of underlayment. installing to avoid condensation problems.
• Consult local building code and roof cladding
manufacturer for underlayment edge and end overlap
and fastening requirements that may differ from Tyvek'
Protec"instructions.Follow the more restrictive requirements.
• Where required by local building code,apply selfadhering
waterproof underlayment as required by code
according to manufacturer's instructions and Tyvek°
Protec"for successive courses.
• Tyvek'Protec'provides protection against leaks under
all types of roof coverings identified by ICC-ES AC188.
INSTALLATION
1. La courses of DuPont'Tyvek'Protec"horizontal) in"shingle 5.A t Tyvek'Protec"with two layers on roofs with
Y Y Y 9 PP Y Y Y
style"fashion following the lap lines provided in 4" slopes between 2:12 and up to 4:12.Begin with a 26"
course overlaps and 6"end laps beginning along the eave undercourse strip parallel to the eave edge,and then
edge.Offset end laps in successive courses by 6 feet. cover with a full width sheet.Overlap successive sheets
2. When attaching DuPont-Tyvek'Protec"to the roof by 26".
sheathing: 6.Install Tyvek'Protec"over drip edges along eave edge
When used under tile,slate,cedar and metal roof and under drip edges along rake edges.
claddings,1"diameter(min)metal or plastic Lap Tyvek'Protec"8"(min)onto walls.
(ring shank or smooth shank)cap-nails or 7 Line roof valleys with a sheet of Tyvek'Protec"prior to
cap-staples are required.
- When used under asphalt or synthetic shingles, installing horizontal courses of Tyvek'Protec".Lap the
1"diameter(min)metal or plastic cap-nails or ends of horizontal Tyvek'Protec"courses over the
capstaples are recommended.Un-capped staples or valley sheet by 6".
standard roofing nails may be used if shingles are 8.At ridges and hips where ridge vents will not be
installed within 36 hours(unless rain or high winds applied,cross-lap Tyvek'Protec"from one roof plane
are expected).Use of un-capped fasteners may result onto the other by 6".For additional weather
in a risk of blow off or leakage around the fastener protection,apply a 24"wide sheet of Tyvek'Protec"
penetrations during a wind or rain event across hips and ridges.
-All anchoring must be performed flush to the roof
and 90 degrees to the roof deck. Warranty
3. Install fasteners 12"on center(o.c)along course and end Tyvek'Protec"is covered by a limited product
over-laps and a single row 24"on center along the middle replacement warranty:
line of the field.Use the printed pattern as a guide. - Tyvek'Protec"120:30 years
4.In high wind zones(at or above 100 mph per IRC • Tyvek`Protec"160:40 years
R301.2),fasteners must be installed at all printed - Tyvek'Protec"200:50 years
locations on the Tyvek'Protec".It must be fastened
using corrosion-resistant metal or plastic cap nails with Warranty is offered DuPont for builders,general
head diameter of at least 1"and a thickness of at least contractors,or professional
ional installers.This is not a
a
a a consumer warranty.To obtain a copy of the warranty please
gauge sheet metal.The cap-nail shank shall a
minimum of 12 gauge(0.105 inches)with a length to visit www.tyvek.com/protec or call)-800 448-9835.
penetrate through the roof sheathing of a minimum of
%inch into the roof sheathing.
OUPONT!
Tyvek. For more information about
DuPont-Tyv eko Protec'",
Protec,~ please call1-800-448-9835 or
ROOFING UNDERLAYMENTS visit us at www.tyvek.com/protec
NOTICE:No freedom from any patent owned by DuPont or others is to be inferred.Because use conditions and applicable laws may differ from one location to another and may change with time
customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customers workplace and disposal practices are
in compliance with applicable laws and other government enactments.The product shovrn in this literature may not be available for sale and/or available in all geographies where DuPont is represented.
The claims made may not have been approved for use in all countries or regions.DuPont assumes no obligation or liability for the information in this document References to'DuPont'or the'Company
mean the DuPont legal entity selling the products to Customer unless otherwise expressly noted.NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRFTTEN WARRANTIES
SPECIFICALLY PROVIDED BY DUPONT.ALL IMPLIED WA.RRAPITIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.The buyer assumes
all risks as to the use of the material-Buyer's exclusive remedy or any claim(including without limitations,negligence,strict liability,or tort)shall be limited to the refund of the purchase price of the
material.Failure to strictly adhere to any recommended procedures shall release DuPont Specialty Products USA,LLC or its affiliates,of all liability with respect to the materials or the use thereof.
The information herein is not intended for use by non-professional designers,applicators or other persons who do not purchase or utilize this product in the normal course of their business.
CAUTION:When cured,these products are combustible and will burn if exposed to open flame or sparks from high-energy sources Do not expose to temperatures above 240°F(116°Q.For more infarmagarL consult
(Material)Safety Data Sheet((M)SDS),call DuPont at 1-8E6383-BLUE(683)orcontact your local building Inspector.in an emergency,call 1.989-636-4400 in are U.S or 1.519-3 3 9 3 711 in Canada.The bloviing agent
contained within this product can exhibit vapor flame limits under the right conditions If specific operating conditions are such that concentrations of the blowing agent above the lower flammable limit can accumulate
in areas with high relative humidity and in the presence of high-energy electrical discharges or other ignition sources,additional measures such as increased ventilation or coded electrical equipment(class one,division two)
may be varranted.D0 NOT SMOKE DURING USE.DO NOT USE NEAR ANYOPEN FLAME OR ELECTRICAL SOURCE.OUTDOOR USE ONLY.INDOOR USE INCREASES LIKELIHOOD OF IGNITABLE CONOITIONSINSTASTIK-Quik Set
Commercial Roofing Adhesive contains isocyanate and a blowing agent Read the label and(Material)Safety Data Sheet 1(141SDS)carefully before.use Wear glovds,and goggles or safety glasses Provide_adequate ventilation
or wear proper respiratory protection Contents under pressure.For outside use only.
DuPont-,the DuPont Oval Logo,and all trademarks and service marks denoted with°i,°'or'are
owned by affiliates of DuPont de Nemours,Inc unless otherwise noted O 2020 DuPont
43-D700784-erdJA-0220 CDP
intertek Code Compliance Research Report
Total Quality.Assured. CCRR-1062
Issue Date:05-25-2016
Revision Date:01-26-2021
Renewal Date:01-31-2022
DIVISION:070000—THERMAL AND MOISTURE PROTECTION Dupont" Tyvek® Protec'" 160 is a mechanically attached
Section:07 30 05—Roofing Felt and Underlayment synthetic underlayment comprised of an embossed non-
woven top scrim and a woven bottom scrim with a polymeric
REPORT HOLDER: laminated facer. The underlayment has an overall weight of
DuPont de Nemours,Inc. 3.27 pounds per 100 square feet, and it is available in rolls
1501 Larkin Center Drive 48 inches wide by 250 feet long.
Midland,MI 48674
(989)638-4318 DupontTM Tyvek® Protec'" 200 is a mechanically attached
www.dur)ont.com/buildins synthetic underlayment comprised of an embossed non-
woven top scrim and a woven bottom scrim with a polymeric
REPORTSUBIECT: laminated facer. The underlayment has an overall weight of
Dupont' Tyvek® Protec'" 120, 160, and 200 Roofing 3.58 pounds per 100 square feet, and it is available in rolls
Underlayments 48 inches wide by 250 feet long.
1.0 SCOPE OF EVALUATION 4.0 INSTALLATION
This Research Report addresses compliance with the following 4.1 General:
Codes:
2018,2015,and 2012 International Building Code®(IBC) Installation of the underlayments must comply with the
n 2018,2015,and 2012 International Residential Code®(IRC) applicable Code, this report, and the report holder's
2020 Florida Building Code(FBC)—See Section 8.1 published installation instructions.
2.0 USES The underlayments must be installed in accordance with the
subsections of IBC Section 1507 and IRC Section R905
Dupontm Tyvek® ProtecTM 120, 160, and 200 underlayments applicable to the roof covering being installed. The
are used in the field of the roof as an alternative to the ASTM underlayments must be laid with the print side up,with laps as
D226, Type I and Type ll, roof underlayments specified in required by the applicable Code, evaluation report, or
Chapter 15 of the IBC and Chapter 9 of the IRC. manufacturer's instructions,whichever is more restrictive.
The underlayments may be used in areas of the roof required The roof covering may be installed immediately following the
by IBC Section 1507 or IRC Section R905 to have an ice barrier underlayment application and the underlayment must be
roof underlayment,when installed as noted in Section 4.2. covered within the time designated in the report holder's
published installation instructions.
The underlayments may be used as components of classified
assemblies when installed as described in this report. 4.2 Ice Barrier:
The underlayments have been evaluated for the properties as In areas of the roof required by IBC Section 1507 or IRC
listed in Table 1. Section R905 to have an ice barrier,two layers of DupontTM
Tyvek° ProtecTM' 120, 160, or 200 underlayment, solidly
3.0 DESCRIPTION cemented together with a low solvent based roofing cement
complying with ASTM D4586 Type 1(asbestos free), may be
Dupont'" Tyvekm Protec7' 120 is a mechanically .attached used provided the ice barrier extends up the roof a minimum
synthetic underlayment comprised of an embossed non- distance of 24 inches inside the interior wall line of the
woven top scrim and a woven bottom scrim with a polymeric building. The underlayment installed in the field of the roof
laminated facer. The underlayment has an overall weight of must overlap the ice barrier.
2.25 pounds per 100 square feet, and it is available in rolls
48 inches wide by 250 feet long.
(a 545 E.Algonquin Road•Arlington Heights•Illinois•60005
intertek.com/buildin
Intertek PCA-101
Version:21 December 2017 5FT-CCRR-0P-40b
ton .
Code Compliance Research Report CCRR-1062 Page 2 of 3
4.3 Fire Classification: 7.0 IDENTIFICATION
The underlayments may be used as a component of a The DupontTM Tyvek® ProtecTM 120, 160 and 200
classified roof assembly when specifically recognized as such underlayments are imprinted with the report holder's name,
in a listing approved by the Code official. The underlayments the Intertek Mark, and the Code Compliance Research Report
may also be used as an alternative to the underlayments number(CCRR-1062). Each roll of the product is also labeled
specified in the Code for roof coverings permitted under the with installation instructions,roll dimensions and weight.
Exceptions to IBC Section 1505.2 and IRC Section R902.1 and CC„Ce
may be used where non-classified roofing is permitted in IBC Section 1505.5. E A��
5.0 CONDITIONS OF USE Intertek
The underlayments described in this Research Report comply 8.0 OTHER CODES
with,or are suitable alternatives to,what is specified in those
Codes listed in Sections 1.0 and 2.0 of this report, subject to 8.1 Florida Building Code:
the following conditions:
8.1.1 Scope of the Evaluation: Dupont'"" Tyvek® ProtecTM
5.1 Installation must comply with this Research Report,the 120, 160, and 200 underlayments were evaluated for
manufacturer's published installation instructions, and the compliance with the 2020 Florida Building Code—Building
applicable Code. In the event of a conflict between the and the 2020 Florida Building Code—Residential.
manufacturer's instructions and this. report, this report
governs. 8.1.2 Conclusion:The Dupont'""Tyvek® ProtecTM 120, 160,
and 200 underlayments described in Section 2.0 to 7.0 of
5.2 Installation is limited to use with approved mechanically this report comply with the 2020 Florida Building Code —
attached roof covering systems. Building and the 2020 Florida Building Code—Residential,
including High-velocity Hurricane Zones (HVHZ), subject to
5.3 Installation is limited to roof systems that do not involve the following conditions:
hot asphalt or coal-tar pitch. The underlayment must be installed in accordance with the
provisions noted in Sections 2.0 through 8.0 of this report,
5.4 Installation is limited to roofs with a slope of 2:12(17%) Sections 1507 and 1518 of the Florida Building Code —
or greater. Building, and Section R905 of the Florida Building Code—
Residential
5.5 Attic ventilation must be provided in accordance with 3 Intertek is an approved evaluation entity and quality
the applicable Code since there are no requirements to assurance entity pursuant to Florida Statute 553.842 —
evaluate vapor permeability of the underlayment. Product Evaluation and Approval
Use of the underlayments in discontinuous roof tile
5.6 The underlayments are manufactured under a quality systems is outside the scope of this report
control program with inspections by Intertek Testing Services
NA Inc. 9.0 CODE COMPLIANCE RESEARCH REPORT USE
6.0 SUPPORTING EVIDENCE 9.1 Approval of building products and/or materials can only
be granted by a building official having legal authority in the
6.1 Reports of tests in accordance with ASTM E108. specific jurisdiction where approval is sought.
6.2 Data in accordance with ICC-ES Acceptance Criteria for 9.2 Code Compliance Research Reports shall not be used in
Roof Underlayments (AC188), dated February 2012 any manner that implies an endorsement of the product by
(editorially revised December 2015). Intertek Testing.
6.3 Intertek Listing Report titled "DuPont Synthetic Roofins 9.3 Reference to the https://bpdirectory.intertek.com is
Underlayments". recommended to ascertain the current version and status of
this report.
545 E.Algonquin Road •Arlington Heights•Illinois•60005
intertek.com/building
Intertek PCA-101
Version:21 December 2017 SFT-CCRR-OP-40b
on
Code Compliance Research Report CCRR-2062 Page 3 of 3
TABLE 1—PROPERTIES EVALUATED
PROPERTY IBC SECTION' IRC SECTION' FBC(BUILDING) FBC(RESIDENTIAL)
104.11,1506,and R104.11,R904,and 104.11,1507,and
Physical Properties R904 and R905
1507 R905 1518.4
Fire Classification 1505 R902.1 1505 R902
Ice Barrier 1507 R905 N/A N/A
'Referenced sections apply to 2018 IBC and IRC
I
III
I
I
This Code Compliance Research Report("Report')is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and
its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than
to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Report.Only the Client is authorized to permit
copying or distribution of this Report and then only in its entirety,and the Client shall not use the Report in a misleading manner. Client further agrees and
understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of
the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification
and this Report does not represent authorization for the use of any Intertek certification marks.Any use of the Intertek name or one of its marks for the sale or
advertisement of the tested material,product or service must first be approved in writing by Intertek.
(a 545 E.Algonquin Road•Arlington Heights a Illinois•60005
intertek.com/building R
Intertek aca-101
Version:21 December2017 SFr-CCRR-OP-40b