Loading...
HomeMy WebLinkAboutAPPROVED HARDIE PLANK LAP SIDING NOABCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL10477-R8 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer James Hardie Building Products Address/Phone/Email 10901 Elm Ave Fontana, CA 92337 (909) 641-0498 rathisha.sabaratnam@jhresearchusa.com Authorized Signature Rathisha Sabaratnam rathisha.sabaratnam@jhresearchusa.com Technical Representative Rathisha Sabaratnam Address/Phone/Email 10901 Elm Avenue Fontana, CA 90631 (909) 641-0498 rathisha.sabaratnam@jhresearchusa.com Quality Assurance Representative Rathisha Sabaratnam Address/Phone/Email 10901 Elm Avenue Fontana, CA 92337 (909) 614-0498 rathisha.sabaratnam@jhresearchusa.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report V. Andrew Tan Florida License PE-81662 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2023 Validated By John Southard, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL10477_R8_COI_2001-10 Letter of Independence.pdf Referenced Standard and Year (of Standard)Standard Year ASTM C1186 2012 ASTM E330 2014 Equivalence of Product Standards Certified By Sections from the Code Page 1 of 2Florida Building Code Online 5/10/2021https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I487... Product Approval Method Method 1 Option D Date Submitted 12/14/2020 Date Validated 01/05/2021 Date Pending FBC Approval 01/06/2021 Date Approved 02/09/2021 Summary of Products FL # Model, Number or Name Description 10477.1 Artisan® Lap Siding 5/8 inch thick fiber-cement lap siding with tongue and groove end joints. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: For use in HVHZ install in accordance with Miami Dade County Florida NOA 20-0730.07; For use outside HVHZ install in accordance with manufacturer's installation instructions. Installation Instructions FL10477_R8_II_Artisan-LAP-Install-Instr.pdf Verified By: V. Andrew Tan 81662 Created by Independent Third Party: Yes Evaluation Reports FL10477_R8_AE_2001-10.1.2 Artisan Lock Joint Siding Analysis CMU.pdf FL10477_R8_AE_2001-10.1-1 Artisan Lap Siding Analysis.pdf FL10477_R8_AE_2001-14.4 NOA Letter of Compliance_Artisan Lap.pdf Created by Independent Third Party: Yes 10477.2 Artisan® Siding with Lock Joint System 5/8 inch thick fiber-cement siding with interlocking horizontal and vertical joints Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: For use in HVHZ install in accordance with Miami Dade County Florida NOA 20-0730.05; For use outside HVHZ install in accordance with manufacturer's installation instructions. Installation Instructions FL10477_R8_II_Artisan-Lock-Joint-Install-Instr.pdf Verified By: V. Andrew Tan 81662 Created by Independent Third Party: Yes Evaluation Reports FL10477_R8_AE_2001-10.1.2 Artisan Lock Joint Siding Analysis CMU.pdf FL10477_R8_AE_2001-10.1.3 Artisan Lock Joint System Analysis.pdf FL10477_R8_AE_2001-14.2 NOA Letter of Compliance_ Artisan LJS.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Page 2 of 2Florida Building Code Online 5/10/2021https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I487... Florida Product Approval Artisan® Lap Siding x For use inside HVHZ: o Artisan Lap Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 20-0730.07. Consult the Artisan Lap product installation instructions on the follow pages for all other installation requirements. x For use outside of HVHZ, o Artisan Lap Siding fastener types, fastening schedule, and installation shall be in accordance with CAE Engineering Reports No.:2001-10.1.1. Consult the Artisan Lap product installation instructions on the follow pages for all other installation requirements. E IMPORTANT:FAILURETOFOLLOWJAMESHARDIEWRITTENINSTALLATIONINSTRUCTIONSANDCOMPLYWITHAPPLICABLEBUILDINGCODES MAYVIOLATELOCALLAWS,AFFECT BUILDINGENVELOPEPERFORMANCEANDMAYAFFECTWARRANTYCOVERAGE.FAILURETOCOMPLYWITHALLHEALTHANDSAFETYREGULATIONSWHENCUTTINGANDINSTALLING THIS PRODUCT MAY RESULT IN PERSONAL INJURY. BEFORE INSTALLATION, CONFIRM YOU ARE USING THE CORRECT HARDIEZONE® PRODUCT INSTRUCTIONS BY VISITING HARDIEZONE.COM OR CALL 1-866-942-7343 (866-9-HARDIE) BL STORAGE EA Storeflatandkeepdryandcoveredpriortoinstallation(fig1).InstallingsidingwetorAPsaturatedmayresultinshrinkageatjoints.Protectedgesandcornersfrombreakage.JamesDHardieisnotresponsiblefordamagecausedbyimproperstorageandhandlingoftheproduct D L HANDLING A WhenworkingwithArtisan®sidingandtrimproducts,carrytheproductonedge.Ifonlyone P personiscarryingtheproduct,holditinthemiddleandspreadarmsaparttobettersupport theproduct(fig2).Iftwopeoplearecarryingtheproduct,holditneareachendandonedge (fig 3). Do not lift or carry Artisan products flat (fig 4). Figure1 Figure2 Figure3 Figure 4 CUTTING INSTRUCTIONS OVERVIEW Figure 5 24 in o.c. max 1.Positioncuttingstationsothatwindwillblowdustaway from user and others in working area. 2.Use one of the followingmethods: a.Best:CircularsawequippedwithaHardieBlade® saw blade and attached vacuum dust collection system b.Better: CircularsawequippedwithaHardieBlade sawbladeandadustcollectionfeature (e.g. Roan®Saw) C.Good: CircularsawequippedwithaHardieBlade saw blade –NEVER grind or cut with a power saw indoors. plywood or OSB sheathing water-resistive barrier Installa11/2in starter stripto offstudtongue and groovejoint concrete foundation leave appropriate gap between planks and trim, then caulk*–NEVER dry sweep dust; use wet dust suppression or vacuum to collect dust. Formaximumdustreduction,JamesHardierecommendsusingthe“Best”cuttingpractices. Forbestperformance whencuttingwithacircularsaw,JamesHardie recommends using HardieBlade saw blades. NOTE:JamesHardiemakesnorepresentationorwarrantythatuseofaparticularcutting optionwillassureyourcompliancewithapplicablelawsandsafetyrequirements. Ifyouareunsurewhichcuttingoptionisbestforyourjobsite,consultaqualifiedindustrial hygienistorsafetyprofessional,orcontactyourJamesHardierepresentativeforassistance. ensure a consistent plank angle * Apply caulk in accordance with caulk manufacturers’ written application instructions. ART1701 P1/8 07/18 LAPSIDING|BEADEDLAPSIDING|ACCENTTRIM Visit jameshardiepros.com for the most recent version. Artisan® LapSidingandTrim EFFECTIVE JULY 2018 Artisan®LapSidingandTrim in min4inx4in remove tongueor groovewhenbuttingtrim correct method GENERAL REQUIREMENTS •Artisansidingcan beinstalled over bracedwood orsteel studs,20gauge(33mils)minimumto 16gauge(54mils)maximum,spaced amaximum of 24ino.c.or directly tominimum7/16inthickOSBsheathing.SeeGeneralFasteningRequirements.Irregularitiesinframingandsheathingcanmirrorthroughthefinished application.Correct irregularities before installingsiding. •InformationoninstallingJamesHardieproductsovernon-nailablesubstrates(ex:gypsum,foam,etc.)canbelocatedinJHTechBulletin19atwww.jameshardiepros.com •Awater-resistivebarrierisrequiredinaccordancewithlocalbuildingcoderequirements.Thewater-resistivebarriermustbeappropriatelyinstalledwithpenetrationand junctionflashinginaccordancewithlocalbuildingcoderequirements.JamesHardiewillassumenoresponsibilityforwaterinfiltration.HardieWrap®WeatherBarrier,a non-woven non-perforated housewrap,does comply with building code requirements. •All flashing and clearance details in figs.6-18 MUST be followed when installing James Hardie ®products. •Adjacent finished grademust slope away fromthe building in accordance with local buildingcodes - typically a minimum of 6in.in the first10ft. •Do not use Artisan lap siding in fascia or trim applications. •Do not install James Hardie products such that they may remain in contact with standing water. •Artisan lap siding may be installed on flat vertical wall applications only. •DO NOT use stain,oil/alkyd based paint, or powder coating on James Hardie products. •Forlargerprojects,includingcommercialandmulti-familyprojects,wherethespanofthewallissignificantinlength,thedesignerand/orarchitectshouldtakeinto considerationthecoefficientofthermalexpansionandmoisturemovementoftheproductintheirdesign.ThesevaluescanbefoundintheTechnicalBulletin#8“Expansion Characteristics of James Hardie Siding Products”at www.jameshardiepros.com. •JamesHardieBuildingProductsprovidesinstallation/windloadinformationforbuildingswithamaximummeanroofheightof85feet.Forinformationoninstallations above 60 feet, please contact JH technical support. CLEARANCE AND FLASHING REQUIREMENTS •Artisan lap butt joints are designed to be installed off stud. Do not nail within 2 in. of tongue and groove at end of planks. •James Hardie recommends cutting tongue or groove off when butting into trim boards (fig. 18). •WhenendingArtisanlapatthebottomofawindoworatthetopofawall,afinishingstripsimilartoastarterstripmaybenecessarytoachieveaproperplankangle.Also whencuttingArtisanlaparounddoors,windows,orotherhorizontaltrimapplications,anadditionalstarterstripmaybenecessarytoachieveproperplankangle(fig.7). Figure 6 Roof toWall Min. 1 in Figure 7 Horizontal Flashing Min.¼in Donotcaulk Figure 8 Kickout Flashing Figure 9 Slabs, Path, Steps to Siding Min. 1in Figure 10 DecktoWall Z-Flashing Figure 11 Ground toSiding Figure 12 Gutter to Siding Figure 13 ShelteredAreas Z-Flashing Figure 14 Mortar/Masonry Min. 1in 6 in 1in Min. ¼ in Min. ¼ in Figure 15 Drip Edge Figure 16 Block Penetration Z-Flashing Min. ¼ in Donotcaulk Figure 17 Valley/Shingle Extension Figure 18 Butting to Trim ART1701 P2/8 07/18 Extendshingles atleast1inout fromthefascia when gutters arepresent Asrequired by IRCcodeZ-Flashing L-Flashing Z-Flashing Min. ¼ in JOINT PLACEMENTJOOOOOININININNNNNNNNINNNINNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNIINNNNT PLPLLPLLLLLLLLLPLLLLLLLLLLLLLLLPLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLACAE Artisan® LapSidingandTrim ARTISAN®ACCENT TRIM Artisan Lap and Beaded Lap siding require a trim thickness of 1 1/2 in for proper aesthetics (fig 21). •When installingArtisan ®AccentTrimall clearance & flashing details figs 6 through 18 must be followed. •2-1/2inminimum16ga.finishnailsmaybeusedtoattachArtisanAccentTrimtowoodframeconstruction.ET&Forequivalent fasteners or screws may be used to attachArtisanAccentTrimto steel frame construction. •Fasteninginstructionsaresimilarforallapplications.Whenusingfinishnails,positionnailsnocloserthan1/2infromtheedgesof thetrimandforallotherfastenersnocloserthan3/4in.Fastenersmustbenocloserthan1in.fromendsoftrimandspaceda maximumof16ino.c.Ensuretrimisadequatelyfastened.Note:JamesHardierecommendsinstallingtrimboardssothatseams are not visible from the front facing or street curb view (fig.20). •Flashing is required over all horizontal protruding and exposed trim. Figure19 Figure20 Figure 21 1.5 in thick trim Board Width Pre-built corner Site Built Corners Other areas (e.g. window trim, band boards and fascia) 4 in 1nailevery16intoattachboardstogether+ 2 nails every 16 in each board 2nailsevery16in 2 nails every 16 in 6 in 1nailevery16intoattachboardstogether+ 3 nails every 16 in each board 3nailsevery16in 3 nails every 16 in HARDIETRIM™ TABS & CORNER TABS For Corners, Band Boards, Windows, and Door Applications: ArtisanAccentTrimboardscanbeinstalledwithFlatTabsandCornerTabs,whichprovideconcealedfastening.OnlyHardieTrim™FlatandCornerTabscanbe usedwithArtisanAccentTrimboards to create a concealedfastening. Fastener spacing will vary based on application. Refer to fastener table on page 5. Refer to specific sections in these instructions for required fastener spacing by application (window,band board, etc.) Step1:AttachFlatTabstothebacksideofthetrimusingfour(4)18ga.1/2inLx1/4 inWnarrowcrowncorrosionresistantstaples,equallyspacedinonerow, positioned no closer than 1/2 in from trim edges using a pneumatic staple gun.(Figure 22) Step2:Forwoodframeconstruction,attachthetrimtothebuildingwithminimum2, 6dsidingnailsfastenedthroughtheHardieTrimFlatTabs.ET&Forequivalentfasteners Figure 22 maybeusedtoattachtheFlatTabstosteelframeconstruction.Min 2 in Fasten 4 staples to the center of the nailing ridge. Installation of HardieTrim tabs in Coastal Regions: JamesHardierequiresthatstainlesssteelstaples&fastenersbeused wheninstalling HardieTrimTabsincoastalregions. Installation of HardieTrim Tabs over Pressure Treated Lumber: HardieTrimtabsmustnotcomeindirectcontactwithACQorCApreservative-treatedwood. RefertotheGeneralFasteningsectionofthisdocumentforfurtherinformation. Figure23 Fasten HardieTrim Flat Tab to minimum 7/16inOSBwithmin2, 6d sidingnails ART1701 P3/8 07/18 Artisan Accent Trim 22.5º -45º weather cut Artisan Accent Trim 1-1/2 in top view usingArtisan AccentTrim front facing trim board (see note above) 3 1/2 in Min 1/2 in 16 in OC max HardieTrim FlatTab1-1/2in 3-1/2 in JOINT PLACEMENT JOINT TREATMENTJOINNNNNNNNNNNNNNNNNNNNNNNNNNTPLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLACE Artisan® LapSidingandTrim TRIMMING CORNERS When using HardieTrim tabs prebuild outside corners off the wall: •AttachHardieTrimCornerTabstothebacksideofthetrimusingeight(8)-18ga.1/2inLx1/4inWnarrowcrowncorrosionresistantstaplesusinga pneumaticstapler.EnsuretheHardieTrimCornerTabsarefastenedtightandstraighttothetrimboards.(Figure24) •Forwoodframeconstruction,attachthetrimtothebuildingwith6dsidingnailsfastenedthroughtheCornerTabs.ET&Forequivalentfastenersmaybe used to attach the Corner Tabs to steel frame construction. (Figure 25) •Attach a HardieTrim Corner Tab 1 in from each end and every 20 in o.c. •TIP:Creatingajigfor theworkstationisrecommendedtoensurethecornersarefastenedsecurelyandstraight. (Figure27) Figure24 Use4staplesper Figure25 Figure26 Figure27 For Jig: Fasten 2 in x 4 in HardieTrim™ Corner Tab pieceoftrimto fasten the Corner studs 22.5º - 45º Corner Tabs timber blocks to a work bench Figure28 L-shapedtabto the pre-built corner.Usethe naillineonthe tabsasaguide. Siding nail Corner Tab weather cut x 8 in stud blocks corner studs ArtisanAccentTrimboardscanalsobeinstalleddirectlyto thebuilding(fig.31)aroundcornersusing2-1/2inlong minimum16ga.galvanizedfinishingnailsevery16ino.c. 2-1/2 in Finish nail TRIM APPLICATION FOR WINDOWS, DOORS & OTHER OPENINGS* Trim the opening prior to the installation of the siding (Figure 29). PlaceaFlatTabattheendofeachtrimboardandonetabevery16inOC. Figure 31 Flashingneedstobe Water-resistive Barrier 1/4 in gap Do notcaulk AttachthetrimboardsandFlatTabsaroundtheopeningasshownin Figures 29 and30.Figure 30 tucked under the water resistivebarrierandover the FlatTabs. between the siding and the flashing. Figure 29 Sidetrimpiecesgoto thetopofthewindow. Bottom trim piece isthewidthofthe window. Headerpiecespansthewindow includingthesidetrimpieces. 1/8 in caulked gap is left between siding and the side trim pieces. *Followyourwindow/doormanufacturersinstallationinstructionsforcaulkingguidancebetweenwindow/doortrim.ART1701 P4/8 07/18 2 ww Artisan Fasten 2 in Accent Trim to the timber JOINT PLACEMENT JOINT TREATMENTJOINNNNNNNNNNNNNNNNNNNNNNNNNNTPLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLACE Artisan® LapSidingandTrim BAND BOARD AflashingisrequiredoverthetrimandHardieTrimFlatTabs.(Figure34)TerminateendsoftheBandBoardintoTrimorSidingormitercuttheedgesofthetrim atthecornersofthebuilding.PlaceaHardieTrimFlatTabattheendofeachtrimboardandonetabeverystudatamaximumof16ino.c. TheHardieTrimFlat Tabsshouldbeattachedtothetriminanalternatingpatterntothetopandbottomofthebandboard(Figure32&33).Use16ga.galvanized2inlongfinish nails to ensure proper fastening ifneeded. Figure32 Figure33 HardieTrim Flat Tabs 16 in o.c. max Fasten4staplestothecenter ofthenailingridge Figure34 Sheathing Blocking Weather-resistive barrier Artisan Lap Siding 1/4 in gap. Do not caulk. Flashing Figure 35 FLUSH FlatandCornerTabs Do not under drive nails. Only use staples to fasten Flat and Corner Tabs to the trim boards. Flat and Corner Tabs Siding nail attaches tab to the wall. HARDIETRIM TAB FASTENER TABLE FlatTabs Caulk Artisan Accent Trim Board APPLICATION FRAMING MATERIAL TAB IS NAILED INTO FASTENER (TAB TO FRAMING) FASTENER (TAB TO ARTISAN ACCENT TRIM) MAX TAB SPACING (INCHES ON CENTER) FLAT TAB Wood Stud (minimum G=0.42)One 6d corrosion resistant siding nail installed through center of flange into framing Four18ga.X1/2inlongX1/4in wide corrosion resistant crown staples,equallyspacedinonerow 16Minimum APA rated 7/16 in OSB Two4dringshankcorrosionresistantsidingnailsequallyspacedinstalled through flange intoframing Minimum 20 gauge steel OneNo.8X1inlongX0.323inheaddiameterscrew(corrosionresistant) installed through flange into framing CORNER TAB Wood Stud (minimum G=0.42) On each flange, Install one 6d corrosion resistant siding nail through flange into framing Foreachpieceoftrim,installFour 18ga.X1/2inlongX1/4inwide corrosionresistantcrownstaples, equallyspaceintworows 20Minimum APA rated 7/16 in OSB Oneachflange,Installtwo4dringshankcorrosionresistantsidingnailsthrough flange into framing Minimum 20 gauge steel Oneachflange,InstalloneNo.8X1inlongX0.323inheaddiameterscrew(corrosion resistant) through flange into framing Wind-BorneDebrisRegion:AdditionalfastenersmaybenecessarywheninstallingtabsinaWind-BorneDebrisRegion,pleasecallTechnicalServices 800-942-7343 with anyquestions. ART1701 P5/8 07/18 HardieTrim FlatTabs 16ino.c.max JOINT PLACEMENT JOINT TREATMENTJOINNNNNNNNNNNNNNNNNNNNNNNNNNTPLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLACE Artisan® LapSidingandTrim ARTISAN®LAP & BEADED LAP SIDING JOINT PLACEMENT ArtisanLapandBeadedLapsidingbuttjointsaredesignedtobeinstalledoffstud.Buttjointsmustnotfall within 4 inches of a stud (fig.38).Do not nail within 2 in.of the end of planks. JOINT TREATMENT InstallfactoryfinishedtongueandgrooveedgestogetheratbuttjointsusingJointFlashing(fig36). STARTER STRIP Install a 1-1/2 in starter strip to ensure a consistent plank angle (fig 5). FASTENER REQUIREMENTS Figure 37 Figure 38 Figure 36 *Asrequiredby local buildingcode GENERAL FASTENINGREQUIREMENTS Fastenersmustbecorrosionresistant,galvanized,orstainlesssteel. Electro-galvanizedareacceptablebutmayexhibitprematurecorrosion. JamesHardierecommendstheuseofquality,hot-dippedgalvanizednails. JamesHardieisnotresponsibleforthecorrosionresistanceoffasteners. StainlesssteelfastenersarerecommendedwheninstallingJamesHardie productsneartheocean,largebodiesofwater,orinveryhumidclimates. Manufacturers of ACQ and CA preservative-treated wood recommend spacer materialsorother physical barrierstopreventdirectcontactofACQorCA preservative-treatedwoodandaluminumproducts.Fastenersusedtoattach HardieTrimTabstopreservative-treatedwoodshallbeofhotdipped zinc-coatedgalvanizedsteelorstainlesssteelandinaccordanceto2018 IRC R317.3 or 2018 IBC 2304.10.5. PNEUMATIC FASTENING JamesHardieproductscanbehandnailedorfastenedwithapneumatictool. Pneumaticfasteningishighlyrecommended.Setairpressuresothatthe fastenerisdrivensnugwiththesurfaceofthesiding.Aflushmountattachment onthepneumatictoolisrecommended. Thiswillhelpcontrolthedepththenail isdriven.Ifsettingthenaildepthprovesdifficult,chooseasettingthatunder •Consultapplicableproductevaluationorlistingforcorrectfastenerstype andplacement toachievespecifieddesignwindloads. •NOTE:PublishedwindloadsmaynotbeapplicabletoallareaswhereLocal BuildingCodeshavespecificjurisdiction.ConsultJamesHardieTechnical Servicesifyouareunsureofapplicablecompliancedocumentation. •Drive fasteners perpendicular to siding and framing. •Fastenerheadsshouldfitsnugagainstsiding(noairspace).(fig.A) •Do not over-drive nail heads or drive nails at an angle. •If nail is countersunk,fill nail hole and add a nail.(fig.B) •Forwoodframing,underdrivennailsshouldbehit flushtotheplankwitha hammer (For steel framing,remove and replace nail). •NOTE:Wheneverastructuralmemberispresent,Artisanlapshouldbe fastenedwithevenspacingtothestructuralmember.Thetablesallowing directtoOSBorplywoodshouldonlybeusedwhentraditionalframingis not available. •Donotusealuminumfasteners,staples,orclippedheadnails. Countersink, Fill&AddNail drivesthenail. (Driveunderdrivennailssnugwithasmoothfacedhammer- snug flush DONOT DO NOT Doesnotapplyforinstallationtosteelframing).FigureA FigureB underdrivenails staple ART1701 P6/8 07/18 water-resistive barrier •Donotnailwithin2inoftongueandgrooveatendofplanks. •Usethenailinglineprovidedontheboardforpropernailplacement. blindnail11/4inmin. overlap Buttjoints mustnot fallwithin4 inches of astud. DONOTUSE NAIL LINE AS LAPLINEwater-resistive barrier stud nailing line24 in O.C.max. PROPER NAIL PLACEMENT DO NOT USE NAIL LINE AS LAP LINE water-resistive barrier Wood Framing •Siding nail (0.09 inshank x 0.221 in HD x 2 1/4 in long) Steel Framing •RibbedBugleHeadscrew(No.8-18x0.323inHDx15/8inlong) min.1 1/4 in overlap BLINDNAILING(required) joint flashing* Artisan lap siding WARNINGWWWWWWWWWWAWWWWWWWWWAWWAWWWWWWWWWWWWWWWWWWAWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWRNRNRNNNNNNNNNNNNNNNNNNNNRNNNNNNNNNNNNNRRNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNINIIIIG Artisan® LapSidingandTrim CAULKING & PAINTING Forbestresults,useanElastomericJointSealantcomplyingwithASTMC920GradeNS,Class25orhigheroraLatexJointSealantcomplyingwithASTMC834. Caulking/Sealantmustbeappliedinaccordancewiththecaulking/sealantmanufacturer’swritteninstructions.Note:Somecaulkingmanufacturersdonotallowtooling. DONOTusestainoroil/alkydbasepaintsonJamesHardie®products. Factory-primedJamesHardieProductsmustbepaintedwithin180daysofinstallation.100%acrylic topcoatsarerecommended.Donotpaintwhenwet.Forapplicationrates,refertopaintmanufacturer’sspecifications.Back-rollingisrecommended ifthepaintissprayed. CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. James Hardie touch-up kits are required to touch-up ColorPlus products. COLORPLUS® TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE •CareshouldbetakenwhenhandlingandcuttingJamesHardieColorPlusproducts.Duringinstallation,useawetsoftclothorsoftbrushtogently wipe off any residue or construction dust left on the product,then rinse with a garden hose. •Touchupnicks,scrapesandnailheadsusingtheColorPlusTechnologytouch-upapplicator.Touch-upshouldbeusedsparingly. Iflargeareasrequiretouch-up,replacethedamagedarea withanewpieceofsidingwithColorPlusTechnology. •Laminate sheet must be removed immediately after installation of each course. •Terminatenon-factorycutedgesintotrimwherepossible,andcaulk.ColormatchedcaulksareavailablefromyourColorPlusproductdealer. •Treatallothernon-factorycutedgesusingtheColorPlusTechnologyedgecoaters,availablefromyourColorPlusproductdealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. PAINTING SIDING AND TRIM WITH COLORPLUS®TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: •Ensure the surface is clean, dry, and free of any dust, dirt, or mildew. •Repriming is normally notnecessary. •100% acrylic topcoats arerecommended. •DO NOT use stain or oil/alkyd based paints on James Hardie products. •Applyfinishcoatinaccordancewithpaintmanufacturers’writteninstructionsregardingcoverage,applicationmethods,andapplicationtemperature. •DO NOT caulk nail heads when using ColorPlus products,refer to the ColorPlus touch-up section. CARE & MAINTENANCE Recommended maintenance includes, but is not limited to: •Washingdowntheexteriorsurfacesevery6to12monthswithagardenhoseorlowpressurewaterspraytoremovedirtanddebris.* •Re-applying of exteriorfinishes.* •Maintainingtheexteriorenvelopeandconnectionsincludingjoints,penetrations,flashings,andsealants(caulking)thatmayprovideameansofmoisture entry beyond the exteriorcladding. •Cleaning out gutters, blocked pipes, and overflows as required. •Pruning back vegetation that is touching the building.Clearance between the siding and shrubs is recommended. •Ensuring required external ground clearances and drainage slopes are maintained. *Refertoyourpaintmanufacturerforwashingandrecoatingrecommendations.ART1701 P7/8 07/18 Artisan® LapSidingandTrim WARNING Highpressurewaterblastandsandblastingmaydamagethesurfaceofthefibercementproduct.Lowpressurewaterspray,asoftmediumbristle(nonmetal) brushismostsuitableforcleaningfibercementproducts.Acidwashingcandamagethefibercementsurfaceandisnotrecommended. Note:Ifusingapressurewasher,caremustbetakentoensurethatthewaterstreamdoesnotdamagethesurfaceofthesiding. Damagetosidingarising fromimproper cleaningor maintenancemay not becoveredbytheJames Hardiewarranty. Usingwidefantipsthat arekept aminimum of 6feet fromthe wall and at pressures under 1500 psi will minimize the chance of damaging the siding. COVERAGE CHART/ESTIMATINGGUIDE Thiscoveragechartismeantasaguide.Actualusageissubjecttovariablessuchasbuildingdesign.JamesHardiedoesnotassumeresponsibilityforover or under ordering ofproduct. Note: Number of 12 ft planks, Includes 5% waste factor. WARNING:Thisproductcanexposeyoutochemicalsincludingrespirablecrystallinesilica,whichisknowntotheStateofCaliforniatocausecancer.FormoreinformationgotoP65Warnings.ca.gov. RECOGNITION:InaccordancewithICC-ESEvaluationReportESR-2290,Artisan®lapisrecognizedasasuitablealternatetothatspecifiedin:the2006,2009,2012&2015InternationalResidentialCodeforOneand Two-FamilyDwellings,andthe2006, 20092012&2015InternationalBuildingCode,Artisanlapisalsorecognizedforapplicationinthefollowing:StateofFloridalistingFL#10477,DadeCounty,FloridaNOANo.15-0122.03.02 andTexasDepartmentofInsuranceProductEvaluationEC-55.Thesedocumentsshouldalsobeconsultedforadditionalinformationconcerningthesuitabilityofthisproductforspecificapplications. HardieTrim® boards may be installed as an equal alternativeto conventional trim permitted for use in; 2006, 2009, 2012 & 2015 International Building Code, Section 1403.1, andthe 2006, 2009, 2012 &2015 International Residence Code for One - and Two - Family - Dwellings, Section R703.1. ©2018JamesHardie BuildingProducts,Inc. Allrightsreserved TM, SMand® denote trademarks or registered trademarks of James Hardie Technology Limited. Productwarranties,safetyinformationandadditionalinstallation informationareavailableatjameshardiepros.com ART1701 P8/8 07/18 DANGER:Maycausecancerifdustfromproductisinhaled.Causesdamagetolungsandrespiratorysystemthroughprolongedorrepeatedinhalationofdustfromproduct.RefertothecurrentproductSafetyData Sheet before use. The hazard associated with fiber cement arises from crystalline silica present in the dust generated by activities such as cutting,machining, drilling, routing, sawing, crushing, or otherwise abrading fibercement,andwhencleaningup,disposingoformovingthedust.Whendoinganyoftheseactivitiesinamannerthatgeneratesdustyoumust(1)complywiththeOSHAstandardforsilicadustand/orother applicablelaw,(2)followJamesHardiecuttinginstructionstoreduceorlimitthereleaseofdust;(3)warnothersintheareatoavoidbreathingthedust;(4)whenusingmechanicalsaworhighspeedcuttingtools, workoutdoorsandusedustcollectionequipment;and(5)ifnootherdustcontrolsareavailable,wearadustmaskorrespiratorthatmeetsNIOSHrequirements(e.g.N-95dustmask).Duringclean-up,useawell maintainedvacuumandfilterappropriateforcapturingfine(respirable)dustorusewetclean-upmethods-neverdrysweep.SILICA WARNINGCoverageAreaLess Openings 1 SQ = (100sq. ft.)Lap WidthExposure 5 1/44 7 1/46 8 1/47 1 27 18 15 2 53 35 30 3 79 53 45 4 105 70 60 5 132 88 75 6 158 105 90 7 184 123 105 8 210 140 120 9 237 158 135 10 263 175 150 11 289 193 165 12 315 210 180 13 342 228 195 14 368 245 210 15 394 263 225 16 420 280 240 17 447 298 255 18 473 315 270 19 499 333 285 20 525 350 300