FL# FL14317-R12 3 j • r-.V G CF E C o V p liTy
Application Type Revision
Code Version 2020 B� ' G
Application Status Approved
Comments
Archived
Product Manufacturer Boral Roofing
Address/Phone/Email 7575 Irvine Center Drive
Suite 100
Irvine,CA 92618
(801) 380-6091
RobinAnderson@boral.com
Authorized Signature Anderson Robin
RobinAnderson @boral_com
Technical Representative Robin Anderson
Address/Phone/Email 1070I So. River Front Parkway
Suite 300
So.Jordan, UT 84095
(801) 380-6091
robinanderson @boral.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaivation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M_ Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PR1 Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2021
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL14317 R12 COI 2021 01 COI NIEMINEN odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
FRSA/TRI 6th Edition 2018
TAS 103 2020
UL1897 2015
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsbCUITKel2OBoXpSjktfpju5SjCf9NBzcOPOgsFgUByg%3d%3d 1/2
5/10/2021 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/15/2021
Date Validated 03/05/2021
Date Pending FBC Approval 03/05/2021
Date Approved 04/13/2021
Summary of Products
FL A Model,Number or Name Description
14317.1 Boral Roof Underlayments Roof underlayments for use in prepared roof assemblies
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL14317 R12 II 2021 03 05 FINAL ER BORAL Underlayments FL14317-
Approved for use outside HVHZ:Yes R12.ptlf
Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure:+N/A/-210 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this Evaluation Reports
application pertains to a particular underlayment FL14317 R12 AE 2021 03 05 FINAL ER BORAL Underlayments FL14317-
system for use in tile roof systems. Refer to ER R12.pQf
Section 5.8.2. 2.)Refer to ER Section 5 for Limits Created by Independent Third Party: Yes
of Use.
Back Nest
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-417-1824 -
The State of Florida is an AAJEEO employer.OoRy_d ht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to apublic-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by tratlitional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(I),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.however email addresses arc public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
®W
Credit Card
Sam
am
https://www.floridabuilding.org/pr/pr_app_dtl.aspx4param=wGEVXQwtDgsbCUITKel2OBoXpSjktfpju5SjCf9NBzcOPOgsFgUBygp/a3da/aid 212
0 NEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the 7t1 Edition (2020) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/Conditions of Use set forth herein.
2. D• •t
Section Prooerty Standar year
1504.3.1 Wind resistance UL 1997 2015
1507.1-1,1507.2.4,1507.2.9.2( Material standard ASTM D1970 2015
R905-1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
TAS 110 Material standard TAS 103 2020
3. REFERENCES:
EntftV Examination Reference Date
ERD(TST 6049) ASTM D1970/D4798 M36790.07.11 09/30/2011
ERD(TST 6049) ASTM D226,01970 B40380.08.12 09/28/2012
ERD(TST 6D49) TAS 103-20(tensile adhesion) C41420.09.12-2 09/11/2012
ERD(TST 6049) ASTM D1970(adhesion) B41940.09.12 09/13/2012
ERD(TST 6049) TAS 103-20(tensile adhesion) B47390.07.14-1 07/31/2014
ERD(TST 5D49) TAS 103-20(tensile adhesion) 347390.09.14 09/04/2014
OC(PDM1838) Physical Properties Equivalency statement 11/02/2017
PRI(TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010
PRI(TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010
PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015
PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015
PRI(TST 5878) TAS 103-20(tensile adhesion) DAPF-002-02-01 03/08/2018
PRI(TST 5878) ASTM D1970 OCF-356-02-01 03/23/2018
PRI(TST 5878) FRSA/TRI 09-2018 OCF-356.02-02 03/22/2018
PRI(TST 5878) TAS 103-20(tensile adhesion) OCF-356-02-04 03/22/2018
PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018
PRI(TST 5878) TAS 103-20(tile slippage clarification) OCF-356-02.02.1 02/03/2021
PRI CMT(QUA9110) Quality Assurance Declaration from Supplier 03/05/2021
4. as ► s
Product Material Standard Plant(s) Description
4.1 BoraI0 TileSeal 50" ASTM D1970 Brentwood, nominal 50-mil thick,polyester-surfaced,self-adhering SBS
NH modified bitumen roof underlayment
4.2 Boral'TileSealw ASTM D1970 and Brentwood, nominal 60-m11 thick,polyester-surfaced,self-adhering SBS
FRSA/TRI 09-18 NH modified bitumen root underlayment
4.3 Boral'MetalSeal"T ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS
FRSA/rR109-18 NH modified bitumen roof underlayment
4.4 GatorSeale ASTM D1970 Brentwood, nominal S5-mil thick,granuie-surfaced,fiberglass reinforced,
NH self-adhering SRS modified bitumen roof underlayment
4.5 CRadel•Pius ASTM D1970 Brentwood, nominal 48-mil thick,fabric-surfaced,fiberglass reinforced,
NH self-adhering SBS modified bitumen roofing underlayment
for use as a base-layer in multi-ply underlayment systems
NEMO ETC,LLC Evaluation Report M35710.12.10-R1i
Cerrylmte of Authorization#32455 7° EDITION(20201 FBC NON-HVHZ EVALUATION FL14317-R72
Boral Roof Underlayments;(602)269,2289 Revision 15:03/05/2021
Page 2 of 6
NEMO (etc.
Certificate ofAuthakation#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION •
Boral Roofing Evaluation Report M35710.12,10-R1S
7575 Irvine Center Drive,Suite 100 FtI43177R12
Irvine,CA.92618 Date of issuance:22/21/2010
(602)269-2288 Revision 1S:03/05/2021
SCOPE:
This Evaluation Report is issued under Rule 61CT20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7rh Edition(2020)Florida Building Code sections noted herein.
0E5CR1'PTtoly"(tu'a}Roof'UhrlaymEfh'!t) �` _ s,,•. ' __ .,=.s _
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COmPuANcE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOJetc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: 10^7e,•,,,
vlLL
Robert J.M.Nieminen,P.E. Thefauimile seal appeanng was authohzed by Robert
Florida Registration No.59166,Florida OCA ANE1983 +/.;Y�;,?•" Nieminen,P.E.on 0.9/05/2021.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
@2018,NEMO ETC,LLC
ONEMOletc.
5.7 Allowable Substrates:
7
Underlayment Application Primer substrates
(Optional)ASTM D41 plywood
Citadel Plus,Boral TileSeal 50"T,Boral self-adhering none ASTM D226 Type II felt or Citadel Plus
TileSeal"T,Boral MetalSeal"T or GatorSeal
ASTM D41 metal(flashing metal,valley metal,etc.)
Boral TileSeal"T,Boral MetalSeal"T self-adhering (Optional)ASTM D41 058
Boral TileSeal"T self-adhering (Optional)ASTM D41 Huber"Zip Deck"
None G-P Gypsum"Dens Deck Prime"
S.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.83.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition, Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)ASTM D41 to the plywood deck
Base Ply: Citadel Plus,self-adhered
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T, self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1'/,"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure=-142.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T, self-adhered and back-nailed within the selvedge-edge side
laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products#410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSeal"T or Boral MetalSeal"r, self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1Y4"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch O,c.
NEMO ETC,LLC Evaluation Report M35730.12.10•RSS
Certiftate of Authorization#32455 P"EDITION 12020)FBC NON-HVHZ EVALUATION FL14317-R12
Boral Roof Underlaymerds,(602)269-2288 Revision 15:03/05/2021
Page 4 of 6
"NEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof
covers. Refer to the installation instructions for multi-ply underlayment options.
_ 'TA8C8`i.`'j#rbtSFh4VEjt+�_PhG' ffi - �u
r..
FBCSettion: 1507.2 2507.3 I507.481507.5�u 15021.7,• 1507.E a 1507.9
Asphalt Gay and Concrete Tile Metal Slate or Wood
Undedayment Mechaniral Adhesive- Slate-Type
Shingles Attach Set Panels Shingles Shingles ShingiesSShakes
Boras TileSeal 50HT Yes No No Yes Yes Yes Yes
(joint strips,3507.2.1.3/R905.2.1.3)
BoratTile5eal"T Yes Yes Yes Yes Yes Yes Yes
(See 5.6.1) (ioint strips,1507.1.1.3/R905.1.1.3)
Boral MetalSeal"T Yes Yes Yes Yes Yes Ves Yes
(See 5.6.1) (joint Stops,15071.1.3/R905A.1.3)
GatorSeal Yes No No No No Yes Yes
Qoatt stops,1507.2.1.3/R905.1.1.3)
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
TABLE SA:ALLOWABLE UNbERLATMENT/TILE•ADMNE Comets tTioNs1
Underlayment Adhesive Florida Product
Approval
Boral TileSeal"T or Boral MetalSeal"T DAP Foam"Touch'n Seal StormBond Roof Tile Adhesive FL14506
DAP Foam"Touch'n Seal StormBond 2 Two-Component
Boral TileSeal"Tor Boral MetalSeal"T FL21374
Polyurethane Roof Tile Adhesive"
Boral TilesealHT or Boral Meta1Seal"T Dupont"Tile Bond—Roof Tile Adhesive" FL22525
Boras TileSealHT or Boral MetalSealHT ICP Adhesives and Sealants"Polysete AH-160" FL6332
Boral TilesealHT or Boral MetalSea1HT ICP Adhesives and Sealants"Polysete RTA-1" FL6276
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report M35710.12.10-R35
certificate of Authorization 032455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R12
Boral Roof Underlayments;1602)269-2298 Revision 15:03/0 512 0 2 1
Page 3 of 6
ONEMOjetc.
6.3.2 Multi-PlyUnderlavment Systems:
One or two plies of Citadel Plus followed by Donal TileSeal SOKI or GatorSeal is allowable for use under
mechanically attached, non-tile prepared roof systems. Limits of use are those associated with the top-layer
material. This is not a requirement,but is allowable if a multi-ply underlayment system is desired,
6�1 °~ .or�pryt1a15ea119'-
6.4.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached,FBC Approved ASTM D226 Type II felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSAJTRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation
instructions.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
6.4.3 Multi-Ply Underlayment Systems:
One or two plies of Citadel Plus followed by Boral TileSealw or Boral MetalSealin is allowable for use under
mechanically attached. non-ti(e prepared roof systems. Limits of use are those associated with the top-layer
material. This is not a requirement,but is allowable if a multi-ply underlayment system is desired.
Refer to Section 5.8.2 for use of Citadel Plus as a base ply membrane in underlayment systems for use under tile-
roof systems.
BUILDING7.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
S. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY
PRI Construction Materials Technologies,LLC(QUA9110);(813)621-5777;bwilson@pricmt.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report M35710.12.10-R15
Certifimre ofAurhwitaHon#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R32
Boral Roof Underlayments;(602)269-2280 Revision 15:03/05/2021
Page 6 of 6
ONEMOletc.
#4 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK#89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSealHT or Boral MetalSealHT,self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1V ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-120.0 psf:
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional)Citadel Plus,self-adhered
Cap Ply: Boral TileSealHT or Boral MetalSealHT,self-adhered
#6 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
5.9 Exposure Umitations:
TABLE 3: ExPOSUREUIiI0"Ift A
Maximum
Undedaymerd Prepared Roof Cover Installation Type Exposure
(days)
GatorSeal Mechanically attached 30
Boral Tile5eal 50HT Mechanically attached ISO
Adhesive-set tile roof system 180
Boral TileSealHT or Boral MetalSealHT
Mechanically attached 180
N/A ton
Citadel Plus(base ply in multi-ply underlayment systems only) (prior to placement of subsequent underlayment)
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE4:TILE SLIPPAGE LIMITATIONS FOOMECT-DECKTRB INSTAUATIONS
Underlayment' 7=Tlle Profile Staging Method Maximum Slope
Boral TileSealHT or Boral MetalSealHr Flat or Lugged Max.10-tile stack 6:12
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate(if applicable).
6.3 Boral TileSeal 50w or GatorSeal:
6.3.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturers installation instructions.
When installed over a mechanically attached,FBC Approved ASTM 0226 Type II felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC,LtC Evaluation Report M35710.12.10-R35
Certii irate ofAuth.,aation N32455 7TH EDITION(2020)FBC NON•HVHZ EVALUATION FL14317-R12
Soral Roof Underlayments;(602)269-2288 Revision 15:03/05/2021
Page 5 of 6