NOTICE OF ACCEPTANCE NOA www,miamidndc.eovleevnorov
Boral Roofing,LLC
7575 Irvine Center Drive,Suite 100
Irvine,CA 926113 F
SCOPE:
'This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Saxony 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.19-0408.01 and consists of pages I through 9-
The submitted documentation was reviewed by Freddy Sentino
NOA No.: 19-0814.01
KaWew 'E , Expiration Date:04/26/22
Approval slate: 11/27/19
Page 1 of 9
ROOFING ASSEMBLY APPROVAL
Cateeorv: Roofing
Sub-Cateeorv: Roofing Tiles
Material: Concrete
Deck Type: Wood
t. SCOPE
This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as
manufactured Boral Roofing LLC in Lake Wales, Fl,and described this Notice of Acceptance. For locations
where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure
values obtained by calculations in compliance with RAS 127 using the values listed in the installation section
herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Saxony goo-Slate Length— 17" TAS 112 Flat profile,interlocking,high-pressure extruded
Width= 13" concrete roof the with two nail holes. For direct deck,
thickness=1-5t32" batten,mortar set or adhesive set applications.
Saxony 900- Length= 17" TAS 112 Flat profile,interlocking,high-pressure extruded
Split Shake Width= 13" concrete roof tile with two nail holes. For direct deck,
thickness= 1-9132" batten,mortar set or adhesive set applications. Top
surface produced with 4 different configurations:
1. Complete the brushed
2. Right half brushed(shown in drawing)
3. Left half brushed
4. No brush
Saxony 900-Shake Length= 17" TAS 112 Flat profile,interlocking,high-pressure extruded
Width= 13" concrete roof the with two nail holes. For direct deck,
thickness= 1-9132" batten, mortar set or adhesive set applications.
Trim Pieces Length: varies TAS-1 12 Accessory trim,boosted Barcelona,concrete roof
Width: varies pieces for use at hips,ridges and rakes.
varying thickness
2.1 MANUFACTURING LOCATION
2.1.1 Lake Wales,FL
NOA No.: 19-0814.01
Expiration Rate:04/26/22
Approval Date: 11127/19
Page 2 of 9
2.2 EVIDENCE SUBMITTED:
Test Ago Test Identifier Test Name/Reoort Date
The Center for Applied 94-094 Static Uplift Testing May 1994
Engineering,Inc. TAS 101 (Mortar Set)
94-060A Static Uplift Testing March, 1994
TAS 101 (Adhesive Set)
25-7183-6 Static Uplift Testing TAS 102 Feb. 1995
(2 Quik-Drive Screws,Direct Deck)
25-7183-5 Static Uplift Testing TAS 102 Feb. 1995
(2 Quik-Drive Screws,Battens)
25-7214-1 Static Uplift Testing TAS 102 March, 1995
(I Quik-Drive Screw,Direct Deck)
25-7214-5 Static Uplift Testing TAS 102 March, 1995
(1 Quik-Drive Screw,Battens)
Project No.107025 Wind Driven Rain Oct. 1994
Test#MDC-77 TAS 100
RedlandTcchnologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix 11&III TAS 108(Nail-On)
Letter Dated Aug, 1, 1994 Wind Tunnel Testing Aug. 1994
TAS 108(Nail-On)
P0631-01 Wind Tunnel Testing July 1994
TAS 108(Mortar Set)
P0402 Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
Atlanta Testing& R1.894/R2.894IR3.894 Physical Properties Aug. 1994
Engineering,Inc. TAS 112
Ceiotex Corporation 520109-1 Static Uplift Testing Dec. 1998
Testing Service 5201114 TAS 101
520191-1 Static Uplift Testing March 1999
TAS 101
Walker Engineering,Inc. Evaluation Calculations 25-7094 February 1996
Evaluation Calculations 25-7496 April 1996
Evaluation Calculations 25-7584P25 7804b-8/25-78044&5 December 1996
25-7848.6
Evaluation Calculations 25-7183 March 1995
Evaluation Calculations Aerodynamic Multipliers 09/01/16
Calculations Two Patty Adhesive Set System April 1999
Evaluation Calculations Restoring Moments Due to Gravity 09/01/16
American Test Lab of RT0617.04-16 TAS 112 06/29116
South Florida
PRI Construction Material COPO-002-02.12 TAS 101 10/12/2016
COPO-002-02-06 TAS 101 10/12/2016
COPO-002-02.05 TAS 101 10/12/2016
BORR-022-02-01 TAS 101 02/25/2019
BORR-022-02-02 TAS 101 02/25/2019
BORR-022-02-03 TAS 101 02/2512019
BORR-022-02-04 TAS 101 02/28/2019
NOA No.;19-0814.01
Expiration Date:04/2G/22
Approval Date. 11/27/19
Page 3 of 9
3. LimiTATiONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set the applications,a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112; appendix 'A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 Mechanically attached tiles minimum slope 4112.
3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
the applicable Building Code.
4. INSTALLATION
4.1 Saxony 900(Slate,Shake&Split Shake)Concrete Roof Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118,RAS 119,and RAS 120,
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions(I x w)
Tile Profile Weight-W(Ibf) Length-1(ft) Width-w (ft)
Saxony 900 10.9 1.417 1.06
Slate Shake&Split Shake
Table 2: Aerodynamic Multipliers -2,(ft)
Tile Z(fta) 3 (ft3)
Profile Batten Application Direct Deck Application
Saxony 900 0.291 0.315
Slate,Shake&Split Shake
Table 3: Restoring Moments due to Gravity -M9(ft4bf)
Tile 2":12" 3":12" 4":12" 5":12" 6"A2" 7":12"or
Profile greater
Saxony 900 Direct Deck Direct Deck Battens Direct Battens I Direct I Battens Direct Battens Direct
Slate &, Shake& I Deck I Deck I Deck I I Deck
Split Shake 7.70 7.62 6.61 7.50 &46 1 7.34 1 6.31 7.16 1 6,13 1 6.95
NOA No.: 19-0814.01
Expiration Date:04/26122
Approval Date: 11/27/19
Page 4 of 9
Table 4: Attachment Resistance Expressed as a Moment-Mr(ft-lbf)
for Mechanically Fastened Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15132" (min. 1913211
plywood) plywood)
Saxony 900 2-10d Ring Shank Nails 30,9 38.1 17.2
State,Shake & 1-10d Smooth or Screw Shank Nail 7.3 9,8 4.9
Split Shake 2-10d Smooth or Screw Shank Nails 14 0 18.8 7A
1 48 Screw 30.8 30.8 18.2
2 48 Screws 51.7 511 24.4
1-10d Smooth or Screw Shank Nail (Field 24.3 24.3 24.2
Clip)
1-10d Smooth or Screw Shank Nall(Eave 19.0 19.0 22.1
Cli
2-10d Smooth or Screw Shank Nails(Field 35.5 35.5 34.8
clip)
2-10d Smooth or Screw Shank Nails(Eave 31.9 31.9 32.2
Clip)
Table 5: Attachment Resistance Expressed as a Moment Mf(ft.-Ibf)
for two Paddy Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Saxony 900 Adhesive' 31.3 Ta 3
Slate,Shake &Split Shake
i
594
i
1 See foam adhesive manufacturers component a roval for in tlatkin requirements. fi
[4.
The Dow Chemical Company TileBond'"one-component foam minimum weight per paddy 13.9 grams.
. ICP-Adhesives Polyset� two-component twoomponent foam,minim m weight per paddy 8 grams.
DAP Products Touch N'Seal Storm Bond 2 twr- om onent foam minimum weight per add 8. rams.
t
E
g
1
I
gF
NOA No.: 19-0914.01
Expiration Date:04126/22
Approval Date: 11/27/19 'E
Pages of 9
't
r
Table 6: Attachment Resistance Expressed as a Moment -Mf(ft-lbf)
for Single Paddy Adhesive Set Systems
Tile Tits Application Minimum Attachment
Profile Resistance
Saxony 900 ICP Adhesives PolysetO AH-160 1193
Slate, Shake&Split Shake Two-component foam 1154
835
606
DAP Products Touch N' Seal Storm 93'
Bond 2 two-component foam 45 6
3 Large paddy placement of45grams of Polysetw AH-160.
4 Large Paddy Placement of 34. rams of Poi set®AH-160 z
5 Mediumm paddy placement of 24 rams of Pot et®AH-160.
6 Medium paddy acement of 16 rams of Pal eW AH-160.
LaMq Wd
y DAP Products Touch N'Seal Storm Bond 2 two-component foam minimum eigihtaerpaddy0orams. -
6 Medium paddy DAP Products Touch N'Seal Storm Bond two-com onent foam minimum weight per paddy 24 grams.
i
Table 7: Attachment Resistance Expressed as a Moment-Mf(ft:Ibn
for Mortar Set Systems
Tile Tile Minimum Attachment
Profile Application Resistance
Saxony 900 Mortar Set6 43.96
Slate,Shake&Split Shake
9 Tile-rite Rocf Tile Mortar
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed t
below,or following statement: "Miami-Dade County Product Control Approved".
OR
LABEL FOR BORAL SAXONY 900"TILES(LAKE WALES FL PLANT)
LOCATED UNDERNEATH TILE
NOA No.:19-0814.01
Expiration Date:04126/22
Approval Date: 11/27/19
Page 6 of 9
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the fallowing:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
PROFILE DRAWINGS
NAIL HOLES
1-5132"(Slate)
17" COVERLOCK
13 "
UNDERLOCK
SAXONY 900-SLATE
NOANo.:19-0814.01
am Expiration Date;04/26112
Approval Date: 11/27119
Page 7 of 9
PROFILE DRAWINGS
NAIL HOLES §a te
1-9132"(Shake)
i�
i
i
17 " 13 "
Note:Available Top Surface Finishes
5. Complete the brushed
6. Right half brushed (shown in drawing)
7. Left half brushed
8. No brush
SAXONY 900-SPLIT SHAKE
NOA No.:19-0814.01
Expiration Date:(14126/22
Approval Date: 11/27/19
Page 9 of 9
PROFILE DRAWINGS
NAIL HOLES
1-913T'(Shake)
170
13 "
SAXONY 900-SHAKE
END OF THIS ACCEPTANCE
NOA No.: 19-0814.01.
Expiration Date:04/26t22
Approval Date: 11/27/19
Page 9 of 9