Loading...
HomeMy WebLinkAboutConstruction PlansSCOFF OF WORK: Existing Master Bedroom Replace EXISTING Shower w/ NEW Closet and 30"w Vanity b Low L' Z � �O Replace Vanes and Fixtures w/ NEW Exising Screened Terrace Existing Living R oom Remove Existing Electrical and Replace w/ NEW Remove Existing Cabinets and Replace w/ NEW e 1 �_ ..- \' Relocate Existing Switch — - For Kitchen Lights hExiatin9 Existing to Li Dining Remove and Replace oom In Existing LL d� u1 — p Existing Kitchen Existing Screened Dining Terrace DEMOLITION FLAN 4" concrete slab repair with fiber -mix 8„ Existing slab -Nr 6 mil vapor barrier cold ,Joint Existing slab New fill Foyer Existing Bedroom 43 / Den remove ana mepiace Existing �V � I W w 0 Existing Bedroom #2 T — Remodel Master Bathroom — Remodel Bathroom #2 — Replace Interior Doors Throughout — Change Master Bath Lighting — No NEW A/C space sum wallboard ood casing 4" Wood Buck Note: all doors to be prehung ical Interior Door Detail gypsum wallboard reinforce corner metal top track bi-fold doc 2"x4" Wood Buck gofer io track D bottom )f door, use f Ir. Bracket 51 pivot /wood Casing gypsum wallboard —reinforce corners 'bi-f old door NTS Replace Vanities and Fixtures with NEW NEW Shower Head NEW Shower Head - NEW Shower Drain Jamb \ 2"x4" Wood Buck Remove Cabinets T�piealI-1=old Door Detail Replacew/NEW Electrical SL,mbol Legend $ Single Pole Switch lCeiling Mounted Light $3 Double Pole Switch Wall Mounted Light w a oFi Waterproof, ground fault interrupter Recessed Can Light w/ Exhaust Fa )New plumbing pipe ,,—,or electrical conduit etc... Slab fi' �ba�r D �ta�l nLs w SCALE 1/4" = I'-O" 2" x 4" top 5/8" drywall ceiling on truss bottom cord 1/2" drywall on 2" x 4' etude at 16" o.c. Finish to match existing New base -board to match existing profile \ 2" x 4" P.T. bottom plate existing slab Interior Non -Bearing Partition Scale: 1/2" = 1'-0" NTS Sidnitary Riser Legend Sanitarg line a17 Bath Tub "P" trap - - Vent Line SH1 Shower "P' trap r7"V" Lavatorg Trap wm� 17 Washing Machine Drain ro­' Sink Trap r' Urinal Water Closet r~' water Fountain Drain "L_ Floor Drain QP Grinder Pump T Clean Out ¢r VM 2' Vent thru Roof '- 2' Vent thru wall 2' Pipe Diameter Designation (2' die) NOTES: - ALL sanitary pipe to be Schedule 40 PVC - Slope hall be no less than 1/8" per foot and no more than 1/4" per foot Existing Existing To Remain M. Bath Existing LAv-� /2" 2l� New SH-1 Connect To Existing - Drain Line - Feild - Verify Exact Location SANITARY RISER 2" 2" AAV JAL 2" I LAV-1 New V anity C.O. Existing Bathroom Sewer Line nts Existing Master Bedroom Flat Ceiling NEW Swing Door \rk 8'-0" A.F.i 3 1 3{ -= Flat Ceiling O so Fr FA I I Maste Bath OIL- — - To Existing \ Lights 1 Remove and Replan In Existing GFC If 1 6 Existing I I Kitchen Existing Screened Dining Terrace Exlsing Screened Terrace Flat ceiling Existing Living R oom 8'-0" A.F.F. Flat Ceiling Specified Shelving \ NEW Switch For Lights Above Island \ Existing \Dining \ \ � oom ANEW Switch For Lights Above Island 8'-O" A.F.F. \ Flat Ceiling Foyer Existing Bedroom 43 / Den rOA 9'-0" A.F.F. Flat Ceiling Existing Bedroom 42 9'-0" A.F.F. Flat Ceiling REPLACE ALL EXISTING interior Doors w/ NEW Owner —specified Doors — Field Verify ALL Door sizes PRIOR to ordering FLOOR FLAN w/ ELECTRIC TYPICAL NOTES: SCALE 1/4" = 1'-0" I. Contractor to verif���tt ALL notes and dimensions prior to proceeding with work 2. Contractor to STf�ICTLY enforce ALL OSHA Requirements. 3. No dissimilar metals to touch. + Drywall at ceilings shall be leveled and attached to bottom chord of trusses with screws per FBC R702.35. 5. ALL wood in contact with concrete shall be pressure treated. 6. ALL wall dimensions are nominal and not finished wall or stud dimensions. 1. ALL plumbing fixtures to be low flow. 8. W811 and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1 9. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2 10. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6, A108.1, A118.1, A118.3, A136.1 and A131.1 11. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall be used as backer for the wall tile in tub areas and wall panels in shower areas. ELECTRIC NOTES: 12. Use copper wire only, no aluminum. 13. Contractor to verify location of electrical service and provider 14. All NEW branch circuits that supply 125v single phase 15 amp or 20 amp outlets shall be protected by combination -type AFCI Circuit Breakers. 15. ALL new receptacles to be Tamper resistant AFCI./ WALL SYMBOL LEGEND 650�K = EXISTING Wails -Size Varies 1p� ��� OtAPt�p''�"� = NEW 2" x 4" non -bearing stud walls - see sections. Insulates Q,pE C pU with R-II batts at bathrooms d between A/C and ' CIE C Non -A/C spaces S�" 0000 O 6- v- m IL w U m � a qN ily W� Q oT a w u� Q Lam U U > W 0 to O Q U_ L_ O L () O � � 4-1 m > N o � v N W� 0 Z W ODMv O Ln aD > a, JQ o VQ 0.��r- Q I Z OD CD NN # q) 0 O rr� rr � x v -1 R3 ul " L U tN LL - WIQ 4 d) 9) In SHEET NO: OF .I. JOB NUMBER: 21-0 rQu. ��oaaao°000;o 0 0 Jam® R.BRAD ®®