HomeMy WebLinkAboutConstruction PlansSCOFF OF WORK:
Existing
Master
Bedroom
Replace EXISTING Shower w/
NEW Closet and 30"w Vanity
b Low
L'
Z �
�O
Replace Vanes and
Fixtures w/ NEW
Exising
Screened
Terrace
Existing
Living
R oom
Remove Existing Electrical
and Replace w/ NEW
Remove Existing Cabinets
and Replace w/ NEW
e
1 �_ ..-
\' Relocate Existing Switch
— - For Kitchen Lights
hExiatin9 Existing
to
Li
Dining
Remove and Replace oom
In Existing
LL
d�
u1
— p Existing
Kitchen
Existing
Screened
Dining
Terrace
DEMOLITION FLAN
4" concrete slab repair
with fiber -mix
8„
Existing slab
-Nr
6 mil vapor
barrier
cold ,Joint
Existing slab
New fill
Foyer
Existing
Bedroom
43 / Den
remove ana mepiace
Existing �V �
I
W
w
0
Existing
Bedroom
#2
T
— Remodel Master Bathroom
— Remodel Bathroom #2
— Replace Interior Doors Throughout
— Change Master Bath Lighting
— No NEW A/C space
sum wallboard
ood casing
4" Wood Buck
Note:
all doors
to be prehung
ical Interior Door Detail
gypsum wallboard
reinforce corner
metal top track
bi-fold doc
2"x4" Wood Buck
gofer
io track D bottom
)f door, use f Ir.
Bracket 51 pivot
/wood Casing
gypsum wallboard
—reinforce corners
'bi-f old door
NTS
Replace Vanities and
Fixtures with NEW
NEW Shower Head
NEW Shower Head -
NEW Shower Drain
Jamb \ 2"x4" Wood Buck
Remove Cabinets
T�piealI-1=old Door Detail Replacew/NEW
Electrical SL,mbol Legend
$
Single Pole Switch
lCeiling Mounted Light
$3
Double Pole Switch
Wall Mounted Light
w a oFi
Waterproof, ground fault interrupter
Recessed Can Light w/ Exhaust Fa
)New plumbing pipe
,,—,or electrical conduit etc...
Slab fi' �ba�r D �ta�l
nLs
w
SCALE 1/4" = I'-O"
2" x 4" top
5/8" drywall ceiling on
truss bottom cord
1/2" drywall on
2" x 4' etude at 16" o.c.
Finish to match existing
New base -board
to match existing profile
\ 2" x 4" P.T. bottom plate
existing slab
Interior Non -Bearing Partition
Scale: 1/2" = 1'-0"
NTS
Sidnitary Riser Legend
Sanitarg line
a17
Bath Tub "P" trap
- -
Vent Line
SH1
Shower "P' trap
r7"V"
Lavatorg Trap
wm�
17
Washing Machine Drain
ro'
Sink Trap
r'
Urinal
Water Closet
r~'
water Fountain Drain
"L_
Floor Drain
QP
Grinder Pump
T
Clean Out
¢r VM
2' Vent thru Roof
'-
2' Vent thru wall
2'
Pipe Diameter Designation (2' die)
NOTES:
- ALL sanitary pipe to be Schedule 40 PVC
- Slope hall be no less than 1/8" per foot and no more than 1/4" per foot
Existing Existing
To Remain
M. Bath
Existing
LAv-�
/2"
2l�
New SH-1
Connect To Existing -
Drain Line - Feild -
Verify Exact Location
SANITARY RISER
2"
2" AAV
JAL
2"
I
LAV-1
New
V anity
C.O.
Existing Bathroom
Sewer Line
nts
Existing
Master
Bedroom
Flat Ceiling
NEW Swing Door
\rk 8'-0" A.F.i
3 1 3{ -= Flat Ceiling
O
so Fr
FA
I
I
Maste
Bath
OIL- — -
To Existing
\ Lights
1 Remove and Replan
In Existing
GFC
If
1 6
Existing
I I Kitchen
Existing
Screened
Dining
Terrace
Exlsing
Screened
Terrace
Flat ceiling
Existing
Living
R oom
8'-0" A.F.F.
Flat Ceiling
Specified
Shelving
\ NEW Switch For
Lights Above Island \
Existing
\Dining \
\ � oom
ANEW Switch For
Lights Above Island
8'-O" A.F.F. \
Flat Ceiling
Foyer
Existing
Bedroom
43 / Den
rOA 9'-0" A.F.F.
Flat Ceiling
Existing
Bedroom
42
9'-0" A.F.F.
Flat Ceiling
REPLACE ALL EXISTING interior
Doors w/ NEW Owner —specified
Doors — Field Verify ALL Door sizes
PRIOR to ordering
FLOOR FLAN w/ ELECTRIC
TYPICAL NOTES: SCALE 1/4" = 1'-0"
I. Contractor to verif���tt ALL notes and dimensions prior to proceeding with work
2. Contractor to STf�ICTLY enforce ALL OSHA Requirements.
3. No dissimilar metals to touch.
+ Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R702.35.
5. ALL wood in contact with concrete shall be pressure treated.
6. ALL wall dimensions are nominal and not finished wall or stud dimensions.
1. ALL plumbing fixtures to be low flow.
8. W811 and Ceiling shall have a flame -spread classification of not greater than
200 per FBC R302.9.1
9. Wall and ceiling finishes shall have a smoke -developed index of not greater
than 450 per FBC R302.9.2
10. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
11. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
ELECTRIC NOTES:
12. Use copper wire only, no aluminum.
13. Contractor to verify location of electrical service and provider
14. All NEW branch circuits that supply 125v single phase 15 amp or 20 amp outlets
shall be protected by combination -type AFCI Circuit Breakers.
15. ALL new receptacles to be Tamper resistant AFCI./
WALL SYMBOL LEGEND 650�K
= EXISTING Wails -Size Varies 1p�
��� OtAPt�p''�"�
= NEW 2" x 4" non -bearing stud walls - see sections. Insulates Q,pE C pU
with R-II batts at bathrooms d between A/C and ' CIE C
Non -A/C spaces S�" 0000
O
6-
v-
m
IL
w U
m
� a
qN ily W� Q
oT a w u� Q
Lam U U >
W
0
to O
Q
U_ L_ O
L ()
O � �
4-1 m
> N
o �
v
N
W�
0
Z W ODMv O
Ln aD
> a,
JQ o VQ
0.��r- Q
I Z OD CD
NN #
q) 0 O rr� rr �
x v -1
R3 ul "
L U tN LL -
WIQ
4
d)
9)
In
SHEET NO:
OF .I.
JOB NUMBER:
21-0
rQu. ��oaaao°000;o 0 0
Jam® R.BRAD
®®