Loading...
HomeMy WebLinkAboutDouglas Dijoy-Engineering Plans_stampedSYSTEM SPECIFICATIONS RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEM 2355 DYER RD PORT ST. LUCIE, FL 34952 SYSTEM SIZE: 19.800 kW MODULE: REC330TP3M BLACK 330W NUMBER OF PANELS: 60 INVERTER: SE7600H-US & SE7600H-US OPTIMIZER: P370 RACKING SYSTEM: SNAPNRACK UR60 RAIL 19.800 kW DC-STC 21/MAY/21 (305)-882-9044 2937 SW 27th AVE SUITE 100 MIAMI, FL 33133 (305)469-9790 SHEET INDEX C1 - COVER PAGE N1 - GENERAL NOTES S1 - SITE PLAN S2 - PANEL LAYOUT S3 - WIND ZONES S4 - STRUCTURAL DETAIL E1 - LINE DIAGRAM E2 - ELECTRICAL CALCULATIONS E3 - WARNING LABELS A1 - PANEL SPECIFICATIONS A2 - RACKING SPECIFICATIONS A3 - MOUNTING SPECIFICATIONS 1 A4 - MOUNTING SPECIFICATIONS 2 A5 - SEALANT SPECIFICATIONS A6 - INVERTER SPECIFICATIONS A7 - OPTIMIZER SPECIFICATIONS C1 - COVER PAGE AHJ: ST. LUCIE COUNTY, FL GOVERNING CODE: 7TH EDITION FLORIDA BUILDING CODE (2020) FLORIDA FIRE PREVENTION CODE 2020 NEC 2017 +1 833 392 2887 208-888 DUPONT STREET TORONTO, ON N1 - GENERAL NOTESGOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC SCALE: 1"=25' NOTES: -SCALE AS SHOWN -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED SAFETY PLAN: -INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME -INSTALLERS SHALL UPDATE NAME, ADDRESS, AND PHONE NUMBER OF NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK NEAREST URGENT CARE FACILITY NAME: ADDRESS: PHONE NUMBER: GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC S1 - SITE PLAN 2355 DYER RD DWELLING SILVER OAK DRPROPERTY LINE SERVICE POINT & UTILITY METERING DISTRIBUTION PANEL (1F) AC DISCONNECT INVERTER 2 INVERTER 1 2355 DYER RD SHED 70'-534"80'-8" 350'-101 2"160'-612"113'-91 2"46'-734"PV SUB PANEL SCALE: 1"=12' PANEL TYPE: REC330TP3M BLACK 330W PANEL SIZE: 66.3" X 39.3" NUMBER OF PANELS: 60 SYSTEM SIZE: 19.800 kW MOUNT COUNT: 186 GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC S2 - PANEL LAYOUT NOTES: -SOLAR PANEL LAYOUT SUBJECT TO CHANGE ACCORDING TO EXISTING CONDITIONS -SCALE AS SHOWN -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED LEGEND METER PVC VENT METAL VENT VENT BOX STRUCTURAL DELIMITER SERVICE MAST SATELLITE ANTENNA SNOW GUARD DOWNSPOUT ELECTRICAL MOUNT RAIL TOP CHORD 36" & 24" FIRE ACCESS PATH 18" FIRE VENTILATION ROOF PITCH: 26.5° SLOPED METAL ROOF AZIMUTHS: 179° & 269° RACKING TYPE: SNAPNRACK UR60 RAIL MOUNT TYPE: S-5 S CLAMP + SNAPNRACK L-FOOT ROOF 1 AREA: 613.56 FT² ARRAY AREA: 307.60 FT² ARRAY PERCENT COVERAGE: 50.13% ROOF 2 AREA: 1330.44 FT² ARRAY AREA: 560.92 FT² ARRAY PERCENT COVERAGE: 42.16% ROOF 2 AREA: 368.90FT² ARRAY AREA: 217.13 ARRAY PERCENT COVERAGE: 58.86 ALL HARDWARE, INCLUDING MOUNTING AND RACKING, TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS. MOUNTING PATTERN SAMPLE ZONE 1 & 2 32" MOUNT PATTERN:STAGGERED MAXIMUM MOUNT SPACING: 32" PEAK SPACING:16" MOUNTING PATTERN SAMPLE ZONE 3 16" MOUNT PATTERN:STACKED MAXIMUM MOUNT SPACING: 16" PEAK SPACING:16"19'-714"11'-6"70'-534"80'-8" PALM TREE TREETOP 20' PALM TREE TREETOP 20'DECIDUOUS TREE TREETOP 15'DECIDUOUS TREE TREETOP 20' DECIDUOUS TREE TREETOP 20' DECIDUOUS TREE TREETOP 15' PALM TREE TREETOP 35' ROOF 1 PITCH 26.5° AZM 179 PALM TREE TREETOP 35' ROOF 2 PITCH 26.5° AZM 269 PALM TREE TREETOP 35' DECIDOUS TREE TREETOP 35' PALM TREE TREETOP 20' DECIDUOUS TREE TREETOP 30' ROOF 3 PITCH 26.5° AZM 179 91 4" ROOF PITCH: 26.5° SLOPED METAL ROOF AZIMUTHS: 179° & 269° RACKING TYPE: SNAPNRACK UR60 RAIL MOUNT TYPE: S-5 S CLAMP + SNAPNRACK L-FOOT SCALE: 1"=12' PANEL TYPE: REC330TP3M BLACK 330W PANEL SIZE: 66.3" X 39.3" NUMBER OF PANELS: 60 SYSTEM SIZE: 19.800 kW MOUNT COUNT: 186 GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC S3 - WIND ZONES NOTES: -SOLAR PANEL LAYOUT SUBJECT TO CHANGE ACCORDING TO EXISTING CONDITIONS -SCALE AS SHOWN -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED LEGEND METER WINDZONE 2 WINDZONE 3 PVC VENT METAL VENT VENT BOX STRUCTURAL DELIMITER SERVICE MAST SATELLITE ANTENNA SNOW GUARD DOWNSPOUT ELECTRICAL MOUNT RAIL TOP CHORD ROOF 1 AREA: 613.56 FT² ARRAY AREA: 307.60 FT² ARRAY PERCENT COVERAGE: 50.13% ROOF 2 AREA: 1330.44 FT² ARRAY AREA: 560.92 FT² ARRAY PERCENT COVERAGE: 42.16% ROOF 2 AREA: 368.90FT² ARRAY AREA: 217.13 ARRAY PERCENT COVERAGE: 58.86 ALL HARDWARE, INCLUDING MOUNTING AND RACKING, TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS. MOUNTING PATTERN SAMPLE ZONE 1 & 2 32" MOUNT PATTERN:STAGGERED MAXIMUM MOUNT SPACING: 32" PEAK SPACING:16" MOUNTING PATTERN SAMPLE ZONE 3 16" MOUNT PATTERN:STACKED MAXIMUM MOUNT SPACING: 16" PEAK SPACING:16"19'-714"11'-6"70'-534"80'-8" PALM TREE TREETOP 20' PALM TREE TREETOP 20'DECIDUOUS TREE TREETOP 15'DECIDUOUS TREE TREETOP 20' DECIDUOUS TREE TREETOP 20' DECIDUOUS TREE TREETOP 15' PALM TREE TREETOP 35' ROOF 1 PITCH 26.5° AZM 179 PALM TREE TREETOP 35' ROOF 2 PITCH 26.5° AZM 269 PALM TREE TREETOP 35' DECIDOUS TREE TREETOP 35' PALM TREE TREETOP 20' DECIDUOUS TREE TREETOP 30' "a" VALUE = 6.68' ROOF 3 PITCH 26.5° AZM 179 91 4" SCALE: NTS NOTES: -SCALE AS SHOWN -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED PANEL TYPE: REC330TP3M BLACK 330W PANEL SIZE: 66.3" x 39.3" RACKING TYPE: SNAPNRACK UR60 RAIL MOUNT TYPE: S-5 S CLAMP + SNAPNRACK L-FOOT GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC S4 - STRUCTURAL DETAIL S-5-S CLAMP STANDING SEAM ROOF SNAPNRACK ULTRA RAIL ALL PURPOSE L-FOOT (90°) SNAPNRACK SEAM CLAMP ROTATION LOCK SNAPNRACK BONDING CLAMP MODULE SNAPNRACK UR-60 RAIL M8-1.25 X 16MM HEX FLANGE BOLT TWO 3/8-24 X 0.80" ROUND-POINT SETSCREWS SOLAR SYSTEM DEAD LOAD: 3.0 PSF WIND VELOCITY - RISK CATEGORY II: 160 MPH (FBC 1620.2) EXPOSURE CATEGORY C (FBC 1620.3) 2x4 @ 24" O/C PITCH 26.5° ROOF 2 BOTTOM CHORD TRUSS TOP CHORD 32'-9" 1' 2x4 @ 24" O/C PITCH 26.5° ROOF 1 BOTTOM CHORD TRUSS TOP CHORD 22'-4" 1' 2x4 @ 24" O/C PITCH 26.5° ROOF 3 BOTTOM CHORD TRUSS TOP CHORD 16'-8" 1' GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC E1 - LINE DIAGRAM NOTE: 1" EMT CONDUIT MAY BE USED IN PLACE OF 3/4" EMT CONDUIT DC+ DC- EGC 240V EGC DC+ PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN, INTEGRATED DC DISCONNECT & ARC FAULT PROTECTION DC- G L1 L2 N G DC+ DC- EGC DC+ DC- AC ISOLATION DEVICE INVERTER 1 SOLAR EDGE SE7600H-US WITH DC DISCONNECT, NEMA3R 1 JUNCTION BOX NEMA3R1 STRING OF 15 REC330TP3M BLACK 330W MODULES EACH CONNECTED TO SOLAREDGE P370 OPTIMIZERS 1 STRING OF 15 REC330TP3M BLACK 330W MODULES EACH CONNECTED TO SOALREDGE P370 OPTIMIZERS 3 DC+ DC- EGC 240V EGC DC+ PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN, INTEGRATED DC DISCONNECT & ARC FAULT PROTECTION DC- G L1 L2 N G DC+ DC- EGC DC+ DC- AC ISOLATION DEVICE INVERTER 2 SOLAR EDGE SE7600H-US WITH DC DISCONNECT, NEMA3R 2 JUNCTION BOX NEMA3R1 STRING OF 15 REC330TP3M BLACK 330W MODULES EACH CONNECTED TO SOLAREDGE P370 OPTIMIZERS 1 STRING OF 15 REC330TP3M BLACK 330W MODULES EACH CONNECTED TO SOLAREDGE P370 OPTIMIZERS 4 PV SUB-PANEL 125A MLO LABELLED "DO NOT ADD LOADS" NEMA3R G N (N) 40A/2P (N) 40A/2P 5 6 L1 L2 N L1 L2 N M N MAIN (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) MAIN SERVICE PANEL 240/120 V 1Ø, 3W, 200A 200A/2P (E) SUPPLY-SIDE TAP 8 G N VISIBLE LOCKABLE MAIN SERVICE AC DISCONNECT 240/120 V 1Ø, 3W 80AF/100AS NEMA3R 7 G EXISTING GEC GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC E2 - ELECTRICAL CALCULATIONS GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC NOTES: 1)ALL LABELING USED OUTDOORS MUST BE ENGRAVED METAL, UV STABILIZED ENGRAVED PLASTIC OR OF A MATERIAL SUFFICIENTLY DURABLE TO WITHSTAND THE ENVIRONMENT INVOLVED. VALUES HAND WRITTEN OR IN WRITTEN IN MARKER ARE NOT ACCEPTABLE PER NEC 2017. 2)LABELS USED INDOORS MAY BE MADE OF DURABLE VINYL OR PAPER 3)DO NOT COVER ANY EXISTING MANUFACTURER APPLIED LABELS WITH INSTALLATION SPECIFIC LABELS 4)LABEL COLORS CHOSEN PER NFPA 70 2017 DIRECTION THAT ANSI Z535-2011 BE USED 5)REQUIREMENTS COMPLY WITH NEC 2017 6)ADDITIONALLY, IT IS HIGHLY RECOMMENDED THAT THE INSTALLER ATTACH A LABEL WITH THE COMPANY NAME AND CONTACT INFORMATION AT THE INVERTER 7)ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(B) FORMAT 1.WHITE LETTERING ON A RED BACKGROUND 2.MINIMUM 3/8 INCHES LETTER HEIGHT 3.ALL LETTERS SHALL BE CAPITALIZED 4.ARIAL OR SIMILAR FONT (NON-BOLD) MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS E3 - WARNING LABELS ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BY ENERGIZED IN THE OPEN POSITION [NEC 690.13] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION CAUTION CONTAINS MULTIPLE POWER SOURCES [NEC 705.12(B)3] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES WARNING PHOTOVOLTAIC POWER SOURCE [NEC 690.31 (G) 3 & 4] PLACE ON ALL JUNCTION BOXES. EXPOSED RACEWAYS EVERY 10' CAUTION: SOLAR ELECTRIC SYSTEM PLACE THIS LABEL WITHIN MAIN SERVICE DISCONNECT (OR ON OUTSIDE DISCONNECT OF OPERABLE WITH COVER CLOSED) [NEC 690.13(B)] ALL AC DISCONNECT SHALL BE LABELED AC PHOTOVOLTAIC DISCONNECT [NEC 690.13(B)] ALL DC DISCONNECT SHALL BE LABELED DC PHOTOVOLTAIC DISCONNECT INTERACTIVE PHOTOVOLTAIC POWER SOURCE [NEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) RATED AC OUTPUT CURRENT: 64A NOMINAL OPERATING AC VOLTAGE:240V RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM [NEC 690.56(C)] PLACE NO MORE THAN 3.3FT FROM SWITCH [NEC 690.56(C)] PLACE AT MAIN SERVICE PANEL SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF DC-TO-DC CONVERTER [NEC 690.53] PLACE AT INVERTER 1 480 VDC 30 AMPS 15 AMPS WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE [NEC 705.12 (B)(2)(3)(b)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF DC-TO-DC CONVERTER [NEC 690.53] PLACE AT INVERTER 2 480 VDC 30 AMPS 15 AMPS WARNING GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC A1 - PANEL SPECIFICATIONS GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC A2 - RACKING SPECIFICATIONS GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC A3 - MOUNTING SPECIFICATIONS 1 GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC A4 - MOUNTING SPECIFICATIONS 2 GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC A5 - SEALANT SPECIFICATIONS GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC A6 - INVERTER SPECIFICATIONS GOLDIN SOLAR PHONE: (305)-882-9044 WWW.GOLDINSOLAR.COM AUTHOR: EE DATE: 21/MAY/21 REV: A PROJECT: 2355 DYER RD MUNICIPALITY: PORT ST. LUCIE, FL ZIP CODE: 34952 CLIENT: DOUGLAS DIJOY 19.800 kW DC-STC A7 - OPTIMIZER SPECIFICATIONS