Loading...
HomeMy WebLinkAboutRidge Vent-product Approval )030 BCIS Home Log In User Registration ! Hot Topics Submit Surcharge Stats&Facts Publications I Contact Us } BCIS Site Map Links Search Product Approval USER:Public User db'pr - Product Approval Menu>Product or Application Search>Application List>Application Detail y.a FL# FL21580-R2 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Florida Metal Products Inc. Address/Phone/Email 6940 Stuart Ave Jacksonville, FL 32254 (904)783-8400 Clark@flamco.com Authorized Signature FLPA Services Flpaserv@yahoo.com Technical Representative Clark jones Address/Phone/Email p c box 6310 jacksonville, FL 32236 (904) 783-8400 Clark@Flamco.com Quality Assurance Representative Clark jones Address/Phone/Email. p o box 6310 jacksonville, FL 32236 (904)783-8400 Clark@flamco,com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the James L. Bucker, P.E.@ CBUCK Engineering Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich,PE Validation Checklist- Hardcopy Received Certificate of Independence FL21580 R2 C0I Certific&e-Offndep_pdif Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 09/25/2020 Date Validated 09/27/2020 Date Pending FBC Approval 10/04/2020 Date Approved 12/16/2020 Summary of Products I'IL# Model, Number or Name Description 21580.1 1-FLAMCO"Off-Ridge Roof Vent" Low profile, off-ridge roof vent for pitched roofs fabricated from 26 gauge, G-90 primed, galvanized steel Limits of Use Installation Instructions Approved for use in HVHZ: No FL21580 R2 II 1 OffRidgeRoofVent EVALREPORT.pdr Approved for use outside HVHZ:Yes Verified By: James L. Buckner,P.E. @ CBUCK Engineering P.E. Impact Resistant: No #31242 Design Pressure: +N/A/-46 Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL21580 R2 AE 1 OffRidgeRoofVent EVALREPORT,pdf instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 21580.2 IA�MCO Gooseneck Roof Vent" Gooseneck style roof vents for sloped shingle or tile roofs 21580.2 fabricated from 26 gauge,G-90 primed,galvanized steel Limits of Use "V Installation Instructions Approved for use in HVHZ: No FL21580 R2 II 2 Goose neckRoofVent EVALREPORT.pdf Approved for use outside HVHZ:Yes Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. Impact Resistant: No #31242 Design Pressure: +N/A/-90 Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL21580 R2 AE 2 GooseneckRoofVent EVALREPORT.pdf instructions as a supplemental guide for attachment. Created by Independent Third Party: Yes 21580.3 3-FLAMCO "RV 10.Ridge Vent" Aluminum Ridge Vents for pitched roofs fabricated from 0.025" Aluminum Limits of Use Installation Instructions --II Approved for use in HVHZ: No FL21580 R2 II 3 RV10 RidgeVent EVALREPORT.pdf Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E. @ CBUCK Engineering P.E. Impact Resistant: No #31242 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL21580 R2 AE 3 RV10 RidgeVent EVALREPORT.pdf instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 0 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:950-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released in response to,a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: igi� Credit Card Safe A. I i t.SUCK &nq1nPer1nQ . rMPP�1f0WW S�rW=rLJreDl (�roQl�aPL-r1nQ - CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report FLAME® "RV10"' Ridge Vent Manufacturer: HoNda Metal products, Deco 6940 Stuart.Avenue Jacksonville, FL 32254 for Florida Product Approval FL 21580.3 R2 Florida Building Code 1th Edition (2020) Method: 2 - B Category: Roofing Sub - Category: Roofing Accessories that are an Integral Part of the Roofing System Product Name: "Ridge Vent" Product Description: Roof Vent Attached To: Wood Deck Prepared by: This item has been electronically signed and sealed by James L.Buckner,P.E.,on this date using a Digital Signature. James L. Buckner, P.E., SECB Printed copies of this document are not considered signed and sealed, and the signature must be verified on any Florida Professional Engineer# 31242 electronic copies. `,ttltlllll/,�/ Florida Evaluation ANE ID: 1916 `. �a,\GEN& `�P�•'•LtCENSF'•��,p Project Manager: Diana Galloway. = *' No31242 Report No. 20-244-RV10-ER (Revises 17-185-RV10-ER,FL 21580.3 RI) LUZ Date: 09/25/20 T . STATE OF •�� ��s •.FCORtOP.•' j�?� ///JONA%-S Contents: Evaluation Report Pages 1—9 2020.09.25 14:33:30-04'00' CBUCK,Inc.dba CBUCK Engineering Phone:(561)491-9927•Email:cbuck@cbuckinc.net•Website:www.cbuc.kinc.net Business:1374 Community Dr.,Jupiter,FL 33458•Corp/Mailing:2637 E.Atlantic Blvd,tt34069,Pompano Beach,FL 33062 FL#: FL 21580.3 R2 Date: 09/25/20 CBU EngineerInQ Report No.: 20-244-RV10-ER Page 2 of 5. Spealc3tfl-j Sz)tr 8a$urc3ll E 1 gineerliraq CBUCK,Inc.Certificate of Authorization#8064 1.0 Manufacturer: Florida Metal Products,Inc. dba FLAMCO 6940 Stuart Avenue Jacksonville, Florida 32254 (800) 634-8400 http://flamco.com 2.0 Manufacturing Plant: Jacksonville, Florida 3.0 Product: 3.1 Product Name: "RV10" 3.2 Product Description: Ridge Vent 4.0 Evaluation Scope: 4.1 Compliance with the following Florida Building Code 7th Edition (2020) 4.2 Evaluation Method: Florida!Product Approval Rule 61G20-3.005 (2) (b) 4.3 Evaluation Classification: Category: Roofing Sub Category: Roofing Accessories that are an Integral part of the Roofing System 4.4 Properties Evaluated Structural (Wind Resistance) Properties 4.5 Limits of Evaluation: This product assembly evaluation is limited to compliance with section 4.1 to section 4.4 of this report. 5.0 Evaluated Uses: FLAMCO "RV10" ridge vent is used as a roof ventilator. 6.0 Product Assembly Description: 6.1 General: The FLAMCO "RV10" are ridge vents for pitched roofs fabricated from nominal 0.025" coated aluminum mechanically attached to Plywood Deck. 7.0 General Assembly as Evaluated: Refer to section 15.0 of this report for product assembly components/materials&standards. 8.0 Support System: (Design of support system 'is outside the scope of this evaluation.) 8.1 Type: Wood Deck 8.2 Description: 15/32" (min.) or greater plywood, or Wood plank deck(based on minimum density/specific gravity of 0.42) 9.0 Slope: Minimum slope shall be 2:12: (and in compliance with FBC Chapter 15 based on the type of roof covering, applicable code sections and in accordance with manufacturer's recommendations.) FL#: FL 21580.3 R2 Date: 09/25/20 C: Report No.: 20-244-RV10-ER Page 3 of 5 Speala f-U Structural E plineerinq CBUCK,Inc.Certificate of Authorization#8064 10.0 Performance: The following test protocols were performed to demonstrate compliance with the intent of the code: 10.1 TAS-100(A)-95 - Wind and Wind Driven Rain Resistance and/or Increased Windspeed Resistance of Soffit Ventilation Strip and Continuous or Intermittent Ventilation System Installed at the Ridge Area. 11.0Code Compliance: 11.1 The product assembly described herein has demonstrated compliance with the Florida Building Code 7th Edition (2020) Section 1708.2. 12.0 Limitations and Conditions of Use: 12.1 Design of support system is outside the scope of this report. Support shall be structural framing members complying with the code and shall be designed by others. 12.2 Scope of"Limitations and Conditions of Use"for this evaluation: This evaluation report for "State Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"State Approval". 12.3 Option for application outside "Limitations and Conditions of Use'-' Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. 12.4 This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107,for any individual structure,site specific or permit design. 12.5 This product has been evaluated to a maximum height of 33 feet. 12.6 Refer to applicable building code for ventilation requirements. 12.7 All metal components and fasteners shall be corrosion resistant in accordance with FBC. 12.8 Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. 12.9 This report does not evaluate the use of this product assembly as described in this report for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) 13.0 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc., (FBC Organization#QUA ID:1824). FL#: FL 21580.3 R2 Date: 09/25/20 ne L ring Report No.: 20-244-RV10-ER.BO NCK r=nq- me Page 4 of 5 �pscilermj SI"rucfrurc5l EngineerIng CBUCK,Inc.Certificate of Authorization#8064 14.0 System/Components 14.1"RV 10 Ridge Vent" 14.1.1 Material: Aluminum 14.1.2 Thickness: 0.025" (nominal,with coating) 14.1.3 Corrosion Resistance: In compliance with FBC Section 1507.4.3: ASTM B209 14.1.4 Overall Product Dimensions (nominal): 14.1.4.1 Length(s): 10 ft. (max.) 14.1.4.2 Width: 8-3/8 in. (±%" nominal) 14.1.4.3 Height: 2-1/4 in. (±%" nominal) 14.2 Fastener: 14.2.1 Base Fastener: Attaches Roof Vent to Deck 14.2.1.1 Type: Smooth or Ring Shank Roofing Nails 14.2.1.2 Size: 6d x 2" (Long) 14.2.1.3 Material: Aluminum 14.2.1.4 Corrosion Resistance: Per FBC Section 1506.5 14.2.1.5 Standard: Per ASTM F 1667 14.3 Roof Adhesive: 14.3.1 Type: Standard Heavy bodied Flashing Cement 14.3.2 Description: Asbestos-free asphalt based roof cement 14.3.3 Application Size: 1/4"thick (min.) 14.3.4 Standard: Per ASTM D 4586 Type I 15.0 Installation Method: (Refer to installation method at the end of this evaluation report.) Prepare deck opening by trimming any shingles or tiles & existing nails that may interfere with ridge vent installation. Apply roof cement to the underside, back and side flanges of the ridge vent. Cement should be a 1/4"thick and extend 2" onto roof underlayment. (Install cement in compliance with manufacturer's installation guidelines.) Position vent base flange beneath loosened shingles and align with deck opening. Attach the unit side flanges to deck with fasteners per Section 14.2 spaced 6" o.c. and 1-1/2"- 2" from each end. Apply Roofing Cement to exposed fastener heads. Minimum fastener penetration thru bottom of support, 3/16". The FLAMCO "RV 10 Ridge Vent" shall be installed in compliance with the installation method listed in this report and applicable code sections of FBC 7th Edition (2020). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 16.0Evaluation Reference Data: 16.1 TAS 100 (A)Wind Driven Rain Test By Fenestration Testing Laboratory, Inc. (FTL) (FBC Organization#TST ID: 1657) Project#16-6647, Lab#9124, Dated: 11/09/16 16.2 Quality Assurance By Keystone Certifications, Inc. (FBC Organization#: QUA 1824) Licensee#440 16.3 Engineering Analysis By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 16.4 Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL#: FL 21580.3 R2 Date: 09/2S/20 Report No.: 20-244-kV10-ER Page 5 of 5 �peala Lj Structural ural r=ng1r =L=r1 q CBUCK,Inc.Certificate of Authorization#8064 Florida Metal Products, Inc. FLAMCO "RV 10" Ridge Vent 2-1/4" (fi/s'I 8-3/811 1/4„) "RV 10 Ridge Vent" Profile View