Loading...
HomeMy WebLinkAboutAPPROVED Wade Nichols - 16.38kWDIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SINGLE-LINE DIAGRAM PV-3 SAFETY LABELS PV-4 SITE PLANS APPENDIXARRAY WIRING BOX DATASHEET INVERTER DATASHEET PROJECT DETAILS PROPERTY OWNER WADE NICHOLS PROPERTY ADDRESS 6008 TANGELO DRFT. PIERCE, FL 34982 ZONING RESIDENTIAL USE AND OCCUPANCYCLASSIFICATION ONE- OR TWO-FAMILY DWELLINGGROUP (GROUP R3) AHJ ST. LUCIE COUNTY UTILITY COMPANY FPL ELECTRICAL CODE 2017 NEC (NFPA 70) FIRE CODE 2020 FFPC 7TH EDITION/2015 NFPA 1 CONTRACTOR INFORMATION COMPANY ATLANTIC KEY ENERGY LLC ADDRESS 7006 STAPOINT CT SUITE B WINTER PARK, FL 32792 PHONE NUMBER (407) 988-0273 SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF APHOTOVOLTAIC POWER SYSTEM. SOLAR PANELS WILL BERACKED USING A PREENGINEERED RACKING SYSTEM. THERACKED MODULES WILL BE ELECTRICALLY CONNECTED WITHDC TO AC POWER INVERTERS AND INTERCONNECTED TO THELOCAL UTILITY USING MEANS AND METHODS CONSISTENTWITH THE RULES ENFORCED BY THE LOCAL UTILITY ANDPERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OFDESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITHENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITHAPPLICABLE CODES AND REGULATIONS. THE DOCUMENTSHALL NOT BE RELIED UPON AS A SUBSTITUTE FORFOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS.THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERSLISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALLAPPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BEINTERPRETED IN A WAY THAT OVERRIDES THEM.CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALLCONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVEPHOTOVOLTAIC SYSTEM WITH NOBATTERY STORAGE DC RATING OF SYSTEM 16,380W AC RATING OF SYSTEM 12,480W AC OUTPUT CURRENT 52.0A INVERTER(S)52 X ENPHASE IQ7-60-2-US MODULE 52 X HYUNDAI HID-S315RGBK ARRAY WIRING (4) BRANCH OF 13 IQ7-60-2-USMICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW LOAD-SIDE AC CONNECTION PER NEC 705.12(B)(2)(3)(C) AT MSP UTILITY SERVICE 120/240V 1Φ ELECTRICAL PANEL 200A MAIN SERVICE PANEL W/200A MCB SITE DETAILS ASHRAE EXTREME LOW -8°C (18°F) ASHRAE 2% HIGH 35°C (95°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL WIND SPEED 160 MPH (ASCE7-16) RISK CATEGORY II WIND EXPOSURECATEGORY B GROUND SNOW LOAD 0 PSF GRID-TIED SOLAR POWER SYSTEMWADE NICHOLS6008 TANGELO DRFT. PIERCE, FL 34982PROJECTSUMMARY DATE: 4/30/21 CREATOR: GV REVIEWER: REVISIONS PV-1 OTHER BUILDING CODE 2020 FL BUILDING CODE PV MODULE MICRO- INVERTER 13 IN BRANCH 13 IN BRANCH 13 IN BRANCH 13 IN BRANCH PM1-52 315W 1 2 3 4 5 6 JUNCTION BOX 4 2 1 3 JB1 AC COMBINERCB2 20A CB1 20A 5 CB3 20A CB4 20A MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-52 52 HYUNDAI HID-S315RGBK INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-52 52 ENPHASE IQ7-60-2-US 240V UNGROUNDED --240W 1.0A 15.0A 48V 97.0% PASS-THRU BOXES AND COMBINERS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 1 GENERIC GEN-AWB-TB-8-4X OR EQUIV.30A 240VAC / 600VDC C1 1 64A 240VAC DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG223NRB OR EQUIV.100A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1-4 4 20A 240VAC CB5 1 70A SYSTEM SUMMARY BRANCH 1 BRANCH 2 BRANCH 3 BRANCH 4 INVERTERS PER BRANCH 13 13 13 13 MAX AC CURRENT 13A 13A 13A 13A MAX AC OUTPUT 3,120W 3,120W 3,120W 3,120W ARRAY STC POWER 16,380W ARRAY PTC POWER 14,783W MAX AC CURRENT 52A MAX AC POWER OUTPUT 13,104W DERATED AC POWER OUTPUT 13,104W NOTES CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT / CABLE OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%)BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LENGTH VOLTAGE DROP 1 1 10 AWG THWN-2, COPPER 0.75" DIA. EMTOR EQUIV.8 20A 10 AWG THWN-2, COPPER 0.76 (55°C)0.7 13A 16.25A 40A 15.96A 90°C 50FT 1.07% 2 1 10 AWG THWN-2, COPPER 8 20A 10 AWG THWN-2, COPPER 0.76 (55°C)0.7 13A 16.25A 15.96A 90°C 50FT 1.07% 3 1 10 AWG THWN-2, COPPER 8 20A 10 AWG THWN-2, COPPER 0.76 (55°C)0.7 13A 16.25A 15.96A 90°C 50FT 1.07% 4 1 10 AWG THWN-2, COPPER 8 20A 10 AWG THWN-2, COPPER 0.76 (55°C)0.7 13A 16.25A 15.96A 90°C 50FT 1.07% 5 1 4 AWG THWN-2, COPPER 3 70A 8 AWG THWN-2, COPPER 1.0 52A 65A 95A 75°C 85A 6 1 4 AWG THWN-2, COPPER 3 N/A 0.96 (33°C)1.0 52A 65A 95A 91.2A 75°C 85A 10FT 0.08% REVISIONS CREATOR: GV REVIEWER: DATE: 4/30/21 SCALE:NTS SINGLE-LINE DIAGRAM PV-2 1 PV-2 SINGLE-LINE DIAGRAM THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE 5 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 6 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 7 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 4 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 240VAC 1.0" DIA. LTNMOR EQUIV. C1 OR EQUIV. OR EQUIV. OR EQUIV. 1.0" DIA. LTNMOR EQUIV. 0.96 (33°C)91.2A 10FT 0.08% 40A 40A 40A 40A 40A 40A 40A GRID-TIED SOLAR POWER SYSTEMWADE NICHOLS 6008 TANGELO DR FT. PIERCE, FL 34982315W 284.3W 9.0A 8.7A 45.3V 36.2V -0.113V/°C (-0.31%/°C)20A 0.75" DIA. EMT 0.75" DIA. EMT 0.75" DIA. EMT ENPHASE Q AGGREGATOR OR EQUIV. 1 2 3 4 THE DC AND AC CONNECTORS OF THE ENPHASE IQ7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(A). MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703. THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF NEC ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO 690.47(B) AND 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO 250.166 AN ADDITIONAL ARRAY GROUNDING ELECTRODE SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTIONS 250.52 AND 250.54 UNLESS THE ARRAY STRUCTURE IS SUITABLE TO SERVE AS A GROUNDING ELECTRODE AS PER NEC SECTION 250.2, THE LOAD SERVED BY THE ARRAY IS INTEGRAL WITH THE ARRAY, OR THE PREMISE'S EXISTING WIRING ELECTRODE IS LOCATED WITHIN 6FT, AS PER NEC SECTION 690.47(B). MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 42.2V AT -2°C (-2°C - 25°C) X -0.113V/C + 39.1V = 42.2V). PV SYSTEM DISCONNECT SHALL BE A 2-POLE BREAKER THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER.7 POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE NEC 705.12(B)(2)(3)(C). OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL. THE PV BREAKER SHALL NOT BE MARKED FOR "LINE" AND "LOAD". THE PV BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. 5 6 8 9 10 PV DISCONNECT 100A 6 7 MAIN SERVICE PANEL ACGEC KWHRKWHR UTILITY METER 240/120V 1ɸ, 3W 200A BUSBAR W/200A MAIN BREAKER SW1 70A 8 9 10 CB5 200A MCB 8 AWG THWN-2, COPPER LOADS (E) 240/120V 1ɸ, 3W 200A MCB ENCLOSUREw/ (N) 200A MCB CB6 200A CB6 1 200A 240VAC GRID-TIED SOLAR POWER SYSTEMWADE NICHOLS 6008 TANGELO DR FT. PIERCE, FL 34982SAFETY LABELS DATE: 4/30/21 CREATOR: GV REVIEWER: REVISIONS PV-3 JB1 - TRANSITION BOX (MODEL NOT SPECIFIED) C1 - AC COMBINER (ENPHASE IQ COMBINER+) SW1 - DISCONNECT (EATON DG223NRB ) MSP - MAIN SERVICE PANEL EACH DISCONNECTING MEANS FORPHOTOVOLTAIC EQUIPMENT (JB1, C1, SW1) ! WARNING !ELECTRIC SHOCK HAZARD. DO NOT TOUCHTERMINALS. TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZED IN THE OPENPOSITION. NEC 690.13(B) AC DISCONNECT (SW1, CB5 IN MSP) MAXIMUM AC OPERATING CURRENT: 52.0A MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.53 AC SOLAR DISCONNECT (SW1, CB5 IN MSP) PHOTOVOLTAIC AC DISCONNECT NEC 690.13(B) SEE NOTE NO. 4 (SW1) NEC 690.56(C) AND IFC 605.11.1 ANY AC ELECTRICAL PANEL THAT IS FED BYBOTH THE UTILITY AND THE PHOTOVOLTAICSYSTEM (MSP) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2017 NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLYWITH ANSI Z535.4, WHICH REQUIRES THAT DANGER,WARNING, AND CAUTION SIGNS USED THE STANDARDHEADER COLORS, HEADER TEXT, AND SAFETY ALERTSYMBOL ON EACH LABEL. THE ANSI STANDARDREQUIRES A HEADING THAT IS AT LEAST 50% TALLERTHAN THE BODY TEXT, IN ACCORDANCE WITH NEC110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BEINSTALLED PROVIDING THE LOCATION OF THE SERVICEDISCONNECTING MEANS AND THE PHOTOVOLTAICSYSTEM DISCONNECTING MEANS IF NOT IN THE SAMELOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN," SHALL BE LOCATED AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/8” TALL LETTERS AND BE REFLECTIVE WITH BLACK TEXT ON A YELLOW BACKGROUND ! WARNING ! EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 705.12(B)(2)(3)(C) SOLAR BREAKER (CB5 IN MSP) NEC 705.12(B)(2)(3)(B) ! WARNING ! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. RAPID SHUTDOWN (SW1) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC 690.56 (C)(3) GRID-TIED SOLAR POWER SYSTEMSITE IMAGES CREATOR: GV REVIEWER: REVISIONS PV-4 Conductor, Conduit, and OCPD Sizing Validation 1. Maximum System Voltage Test 1.1. Enphase inverter w/52 Hyundai HID-S315RGBK (315W)s Array Properties Microinverter Array Enphase inverter w/52 Hyundai HID-S315RGBK (315W)s HID-S315RGBK (315W)s Array Type System Description Module Highest number of modules in series 1in a PV Source Circuit Design Low Temp.-8°C Module Voc 45.3V Temp. Coefficient Voc -0.113V/C NEC Code Calculations A.. Maximum Voltage of PV Source Circuit see 690.7(C) NEC Code Validation Tests 1.PASS WADE NICHOLS 6008 TANGELO DR FT. PIERCE, FL 34982DATE: 4/30/21 SCALE: 1 PV-4 SITE IMAGES NTS 49.08V NEC 690.7(C) requires that if the PV module manufacturer provides a temperature coefficient of open-circuit voltage, it must be used to calculate the PV array's maximum system voltage. It includes an information note recommending the use of the ASHRAE 'Extreme Annual Mean Minimum Design Dry Bulb Temperature' as the design low temperature. Using these values, the module Voc (45.3V) will increase to 45.3V at the design low temperature ( -2°C). (-2°C - 25°C) X -0.140V/C + 45.3V = 49.08V The module Voc at the design low temperature is 49.08V. 49.08V X 1 = 49.08V PV Source Circuit maximum Voc must not exceed 600V 49.08V < 600V = true pe.eaton.comGeneral Duty Cartridge FuseSafety SwitchDG223NRBUPC:782113144252Dimensions:Height: 7 INlLength: 6.42 INlWidth: 8.82 INlWeight:9 LBNotes:Maximum hp ratings apply only when dualelement fuses are used. 3-Phase hp rating shown isa grounded B phase rating, UL listed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.lSpecifications:Type: General Duty/Cartridge FuselAmperage Rating: 100AlEnclosure: NEMA 3RlEnclosure Material: Painted galvanized steellFuse Class Provision: Class H fuseslFuse Configuration: Fusible with neutrallNumber Of Poles: Two-polelNumber Of Wires: Three-wirelProduct Category: General Duty Safety SwitchlVoltage Rating: 240VlSupporting documents:Eatons Volume 2-Commercial DistributionlEaton Specification Sheet - DG223NRBlCertifications:UL ListedlProduct compliance: No Data______________________________________________________________________© 2016 Eaton. All rights reserved. Printed Date : 05/2020Mono-Crystalline Module (HiD-S____RG(BK))310315320Nominal Output (Pmpp)W310315320Open Circuit Voltage (Voc)V40.340.540.6Short Circuit Current (Isc) A9.949.9910.04Voltage at Pmax (Vmpp)V33.133.433.7Current at Pmax (Impp)A9.459.519.57Cell Type-6.25”, mono-crystalline siliconMaximum System VoltageV1,000Temperature Coefficient of Pmax%/K-0.391Temperature Coefficient of Voc%/K-0.31Temperature Coefficient of Isc%/K0.031Electrical CharacteristicsDimensions1,007 mm(39”) x 1,681 mm(66”) x 33 mm(1.3”)Weight18.2 kg (40.1lbs)Solar Cells60 cells in series (6 × 10 matrix) (Hyundai cell)Output Cables4 mm2 (12AWG) cables with polarized weatherproof connectors,IEC certified (UL listed), Length 1.0 m (39.4�)Junction BoxIP65, weatherproof, IEC certified (UL listed)Bypass Diodes3 bypass diodes to prevent power decrease by partial shadeConstructionFront Glass : Anti-reflection coated glass, 3.2 mm (0.126”) Encapsulant : EVA | Back Sheet : Weatherproof filmFrameClear anodized aluminum alloy type 6063 (Black color)*All data at STC (Standard Test Conditions). Above data may be changed without prior notice.Module Diagram (unit : mm)I-V CurvesMono-Crystalline Si Type-Front Side ViewNominal Operating Cell Temperature46°C ± 2Operating Temperature-40 ~ 85°CMaximum System VoltageDC 1,000 V Maximum Reverse Current20A • Only qualified personnel should install orperform maintenance.• Be aware of dangerous high DC voltage.• Do not damage or scratch the rear surfaceof the module.• Do not handle or install modules when theyare wet.Mechanical CharacteristicsInstallation Safety GuideSales & MarketingSales@hyundai-es.co.krIncid. Irrad = 1,000W/m2Incid. Irrad = 800W/m2Incid. Irrad = 600W/m2Incid. Irrad = 400W/m2Incid. Irrad = 200W/m2Current [A]Current [A]Incid. Irrad = 1,000W/m2 Operating Cell Temp = 5°C Operating Cell Temp = 25°C Operating Cell Temp = 45°C Operating Cell Temp = 65°CPrinted Date : 05/2020HYUNDAI SOLAR MODULERGBLACKMono-Crystalline TypeHiD-S310RG(BK) HiD-S315RG(BK)HiD-S320RG(BK)60More Power GenerationIn Low LightAssembledin USA withHyundai CellAll black Module Global brand with powerful financial strength provide reliable 25-year warranty.Hyundai’s Warranty Provisions•12-Year Product Warranty·On materials and workmanshipBoth LID(Light Induced Degradation) and PID(Potential Induced Degradation) are strictly eliminated to ensure higher actual yield during lifetime.Tempered glass and reinforced frame design withstand rigorous weather conditions such as heavy snow and strong wind.Hyundai’s R&D center is an accredited test laboratory of both UL and VDE.PERC technology provides ultra-high efficiency with better performance in low irradiation. Maximizes installation capacity in limited space.Reliable WarrantyPERC TechnologyCorrosion ResistantAnti-LID / PIDUL / VDE Test Labs Mechanical Strength Cells12•25-Year Performance Warranty· Initial year: 97%· Linear warranty after second year:with 0.7%p annual degradation,80% is guaranteed up to 25 yearswww.hyundai-es.co.krVarious tests under harsh environmental conditions such as ammonia and salt-mist passed.About Hyundai Energy SolutionsEstablished in 1972, Hyundai Heavy Industries Group is one of the most trusted names in the heavy industries sector and is a Fortune 500 company. As a global leader and innovator, Hyundai Heavy Industries is committed to building a future growth engine by developing and investing heavily in the field of renewable energy. As a core energy business entity of HHI, Hyundai Energy Solutions has strong pride in providing high-quality PV products to more than 3,000 customers worldwide. UL 1703-3rd Edition - Flat-Plate Photovoltaic Modules and PanelsCertification25A sssembled inUSAHyundaiCell FLASH LOCFLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don’t just divert water, LOC it out!PROTECT THE ROOFInstall a high-strength waterproof attachment without lifting, prying or damaging shingles.LOC OUT WATERWith an outer shield 1 contour-conforming gasket 2 and pressurized sealant chamber 3 the Triple-Loc Seal delivers a 100% waterproof connection.Cut Away ViewHIGH-SPEED INSTALLSimply drive lag bolt and inject sealant into the port 4to create a permanent pressure seal.Cut Away ViewFASTER INSTALLATION. 25-YEAR WARRANTY.FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-27023241LEGAL NOTICEDRAWING NOT TO SCALEALL DIMENSIONS ARENOMINALPRODUCT PROTECTED BYONE OR MORE US PATENTSSOLARMOUNTPART DRAWING4/28/2020FLASHLOC COMP KITREVISION DATE:DRAWING TYPE:DESCRIPTION:FL-A01PRODUCT LINE:1411 BROADWAY BLVD. NEALBUQUERQUE, NM 87102 USAPHONE: 505.242.6411WWW.UNIRAC.COMSHEETPART TABLEP/NDESCRIPTION004085MFLASHLOC COMP KIT MILL, 20 PACK004085DFLASHLOC COMP KIT DARK, 20 PACK678"312"334"214"5/16" x 4" SS LAG BOLTW/ SS EPDM BONDED WASHERFLASHLOC BASEMILL OR DARKSS SERRATED T-BOLTSS SERRATED FLANGE NUT SOLARMOUNTSOLARMOUNT defined the standard in solar racking. Features are designed to get installers off the roof faster. Our grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Systems can be configured with standard or light rail to meet your design requirements at the lowest cost possible. The superior aesthetics package provides a streamlined clean edge for enhanced curb appeal, with no special brackets required for installation.FAST INSTALLATION. SUPERIOR AESTHETICS OPTIMIZED COMPONENTS • VERSATILITY • DESIGN TOOLS • QUALITY PROVIDERLOSE ALL OF THE COPPER & LUGSSystem grounding through Enphase microinverters and trunk cablesSMALL IS THE NEXT NEW BIG THINGLight Rail is Fully Compatible with all SM ComponentsENHANCED DESIGN & LAYOUT TOOLSFeaturing Google Map Capabilities within U-Builder ENDCAPSFRONTTRIMNow Featuring:THE NEW FACE OF SOLAR RACKINGSuperior Aesthetics Package The Enphase IQ Combiner 3C™ with Enphase IQ Envoy™ and integrated LTE-M cell modem with 5-year data plan consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly.Enphase IQ Combiner 3C(X-IQ-AM1-240-3C)To learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Envoy for communicationand control• Includes LTE-M cell modem and 5-year data plan• Flexible networking supports Wi-Fi,Ethernet, or cellular• Optional AC receptacle available for PLC bridge• Provides production metering and optionalconsumption monitoringSimple• Reduced size from previous combiner• Centered mounting brackets support singlestud mounting• Supports back and side conduit entry• Up to four 2-pole branch circuits for 240 VACplug-in breakers (not included)• 80 A total PV or storage branch circuitsReliable• Durable NRTL-certified NEMA type3R enclosure• Five-year warranty• UL listedTo learn more about Enphase offerings, visit enphase.com© 2019 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. 2019-05-31MODEL NUMBERIQ Combiner 3C X-IQ-AM1-240-3CIQ Combiner 3C with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%).Includes Enphase Mobile Connect LTE-M cell modem and 5-year data plan. A Plug-and-play industrial-grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.)ACCESSORIES and REPLACEMENT PARTS (not included, order separately)Consumption Monitoring* CTCT-200-SPLITSplit core current transformers enable whole home consumption metering (+/- 2.5%).Circuit BreakersBRK-10A-2-240BRK-15A-2-240BRK-20A-2P-240Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers.Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01Power line carrier (communication bridge pair), quantity 2XA-PLUG-120-3Accessory receptacle for Power Line Carrier in IQ Combiner 3C (required for EPLC-01)XA-ENV-PCBA-3Replacement IQ Envoy printed circuit board (PCB) for Combiner 3CELECTRICAL SPECIFICATIONSRatingContinuous dutySystem voltage120/240 VAC, 60 HzEaton BR series busbar rating125 AMax. continuous current rating (output to grid) 65 AMax. fuse/circuit rating (output)90 ABranch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)Max. continuous current rating (input from PV) 64 AMax. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker includedProduction Metering CT200 A solid core pre-installed and wired to IQ EnvoyMECHANICAL DATADimensions (WxHxD)37.5 x 49.5 x 16.8 cm (14.75” x 19.5” x 6.63”). Height is 21.06" (53.5 cm) with mounting brackets.Weight7.5 kg (16.5 lbs)Ambient temperature rangeCoolingEnclosure environmental rating-40º C to +46º C (-40º to 115º F)Natural convection, plus heat shieldOutdoor, NRTL-certified, NEMA type 3R, polycarbonate constructionWire sizes•20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors•60 A breaker branch input: 4 to 1/0 AWG copper conductors•Main lug combined output: 10 to 2/0 AWG copper conductors•Neutral and ground: 14 to 1/0 copper conductorsAlways follow local code requirements for conductor sizing.AltitudeTo 2000 meters (6,560 feet)INTERNET CONNECTION OPTIONSIntegrated Wi-Fi802.11b/g/nEthernetOptional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) CellularOptional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included)COMPLIANCECompliance, CombinerUL 1741 CAN/CSA C22.2 No. 107.147 CFR, Part 15, Class B, ICES 003Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Compliance, IQ EnvoyUL 60601-1/CANCSA 22.2 No. 61010-1 * Consumption monitoring is required for Enphase Storage Systems.Enphase IQ Combiner 3C The Enphase Q Aggregator™ and Enphase Q Cable™ are part of the sixth generation Enphase IQ System™. These accessories provide simplicity, reliability, and faster installation times..Enphase Q Aggregator and Q Cable AccessoriesTo learn more about Enphase offerings, visit enphase.comData SheetEnphase Q Cable AccessoriesEnphase Q Aggregator• Reduces electrical labor and eliminates wire nuts for safer, faster installations• Aggregates up to three fully populated 20A branch circuits• Supports solar arrays of up to 11.5 kW with a single rooftop aggregatorEnphase Q Cable• Two-wire, double-insulated Enphase Q Cable is 50% lighter than the previous generation Enphase cable• New cable numbering and plug and play connectors speed up installation and simplify wire management• Link connectors eliminate cable wasteField-Wireable Connectors• Easily connect Q cables on the roof without complex wiring• Make connections from any open connectorand center feed any section of cable within branch limits• Available in male and female connector typesTo learn more about Enphase offerings, visit enphase.com© 2017 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc.2017-04-05Q AGGREGATOR SPECIFICATIONSModel numberQ-BA-3-1P-60Dimensions190 mm (W) x 227 mm (D) x 80 mm (H) (7.5 in (W) x 9 in (D) x 3.2 in (H))Enclosure ratingNEMA3 (up to 45° from horizontal)Temperature range-40° C to +55° C (-40° F to +122° F)ComplianceUL1703, EN62109, UL6703AQ CABLE SPECIFICATIONSVoltage rating600V (connector rating 250 V)Cable temperature rating90° C (194° F)CertificationUL3003, DG cableFlame test ratingFT4ComplianceRoHS, OIL RES I, CE, UV resistant, combined UL for Canada and United StatesCable insulator ratingTHHN/THWN-2 dry/wetQ CABLE TYPES / ORDERING OPTIONSModel NumberMax Nominal VoltageConnector SpacingPV Module OrientationConnector Count per BoxQ-12-10-240250 VAC1.3 m (4.2 ft)Portrait240Q-12-17-240250 VAC2.0 m (6.5 ft)Landscape (60-cell)240Q-12-20-200250 VAC2.3 m (7.5 ft)Landscape (72-cell)200ENPHASE Q CABLE ACCESSORIESNameModel NumberDescriptionEnphase Q AggregatorQ-BA-3-1P-60Combines up to three microinverter branches into one home run.Field-wireable connector (male)Q-CONN-10MMake connections from any Q Aggregator open connectorField-wireable connector (female)Q-CONN-10FMake connections from any Q Cable open connectorCable ClipQ-CLIP-100Used to fasten cabling to the racking or to secure looped cablingDisconnect toolQ-DISC-10Disconnect tool for Q Cable connectors, DC connectors, and AC module mountQ Aggregator sealing caps (male)Q-BA-CAP-10Sealing cap for unused aggregator connectionsQ Cable sealing caps (female)Q-SEAL-10One needed to cover each unused connector on the cablingTerminatorQ-TERM-10Terminator cap for unused cable endsReplacement DC Adaptor (MC4)Q-DCC-2DC adaptor to MC4 (max voltage 100 VDC)Replacement DC Adaptor (UTX)Q-DCC-5DC adaptor to UTX (max voltage 100 VDC)Enphase Q Cable AccessoriesTERMINATOR Terminator cap for unused cable ends, sold in packs of ten (Q-TERM-10)SEALING CAPSSealing caps for unused aggregator and cable connections(Q-BA-CAP-10 and Q-SEAL-10)DISCONNECT TOOLPlan to use at least one per installation, sold in packs of ten(Q-DISC-10)CABLE CLIPUsed to fasten cabling to the racking or to secure looped cabling, sold in packs of ten (Q-CLIP-100) The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency.Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+MicroinvertersTo learn more about Enphase offerings, visit enphase.comData SheetEnphase MicroinvertersRegion: AMERICASEasy to Install• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)Productive and Reliable• Optimized for high powered 60-cell and 72-cell* modules• More than a million hours of testing• Class II double-insulated enclosure• UL listedSmart Grid Ready• Complies with advanced grid support, voltage and frequency ride-through requirements• Remotely updates to respond to changing grid requirements• Configurable for varying grid profiles• Meets CA Rule 21 (UL 1741-SA)* The IQ 7+ Micro is required to support 72-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.To learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-USIQ7PLUS-72-2-US / IQ7PLUS-72-B-USCommonly used module pairings¹235 W - 350 W +235 W - 440 W +Module compatibility60-cell PV modules only60-cell and 72-cell PV modulesMaximum input DC voltage48 V60 VPeak power tracking voltage27 V - 37 V27 V - 45 VOperating range16 V - 48 V16 V - 60 VMin/Max start voltage22 V / 48 V22 V / 60 VMax DC short circuit current (module Isc)15 A15 AOvervoltage class DC portIIIIDC port backfeed current0 A0 APV array configuration1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ 7 MicroinverterIQ 7+ MicroinverterPeak output power250 VA295 VAMaximum continuous output power240 VA290 VANominal (L-L) voltage/range²240 V / 211-264 V208 V / 183-229 V240 V / 211-264 V208 V / 183-229 VMaximum continuous output current1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V)Nominal frequency60 Hz60 HzExtended frequency range47 - 68 Hz47 - 68 HzAC short circuit fault current over 3 cycles5.8 Arms5.8 ArmsMaximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC)Overvoltage class AC portIIIIIIAC port backfeed current0 A0 APower factor setting1.01.0Power factor (adjustable)0.85 leading ... 0.85 lagging0.85 leading ... 0.85 laggingEFFICIENCY@240 V@208 V@240 V@208 VPeak efficiency97.6 %97.6 %97.5 %97.3 %CEC weighted efficiency97.0 %97.0 %97.0 %97.0 %MECHANICAL DATAAmbient temperature range-40ºC to +65ºCRelative humidity range4% to 100% (condensing)Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket)Weight1.08 kg (2.38 lbs)CoolingNatural convection - No fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure ratingNEMA Type 6 / outdoorFEATURESCommunicationPower Line Communication (PLC)MonitoringEnlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy.Disconnecting meansThe AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.ComplianceCA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.Enphase IQ 7 and IQ 7+ Microinverters