Loading...
HomeMy WebLinkAboutAPPROVED Wade Nichols UNIRAC DSRESIDENTIAL UNIVERSAL PV STRUCTURAL PLAN. COMMON SOLAR COMPONENT EXAMPLES SHOWN, APPEARANCE MAY VARY.UNIRAC SOLARMOUNT UNIVERSAL INSTALLATION PLANCURRENT FBC 2020 (7TH EDITION) FLORIDA BUILDING CODE & ALL REFERENCED STANDARDSTHIS UNIVERSAL PLAN IS INTENDED FOR RESIDENTIAL PV INSTALLATIONS CONTRACTOR SHALL COMPLY WITH CURRENT NFPA 1 SOLAR PROVISIONS ALLEN GEZELMAN State of Florida, Professional Engineer License No. PE 59180 16502 Hanna Rd, Lutz, FL 33549PH 813-909-1956Allen@GezelmanPE.com www.GezelmanPE.comPlan Code UNIRAC FLORIDA WIND ZONES ASCE 7-16PV MODULES ON UNIRAC SOLARMOUNT RACKINGCut Away ViewCut Away ViewFLASH LOC ATTACHMENTPZ1' : FIELD-OF-ROOF---- INTERIORPZ1 : FIELD-OF-ROOF---- EXTERIORPZ2 : ROOF PERIMETER(MIN. 3' LEAST OF 40% EAVE HEIGHT OR 10% BUILDING L/W. PZ3: OUTSIDE CORNERSL & W =PZ2, a = PZ2 WIDTH., h = EAVE HEIGHT.S5 PROTEA BRACKETS5-U CLAMPAPPROVED METAL ROOF CLAMPS rev04-15-2021 DESIGNED FOR RISK II, V=ULT170 MPH. EXPOSURE C, & V=ULT160 MPH. EXPOSURE DPAPER PLANS SHALL BEAR SIGNATURE & SEAL If… This item has been electronically signed and sealed by Allen Gezelman on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copiesAKE SOLAR7006 Stapoint Court, Suite B,Winter Park, Florida 32792 407-819-4000I CERTIFY THAT THE SHEETHING & FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.1. THIS IS A SINGLE SHEET UNIVERSAL STRUCTURAL PLAN. ELECTRICAL PLAN ISSEPARATELY SEALED DOCUMENT.2. THIS PLAN OFFERS THREE INSTALLATION METHODS.a. FRAMING METHOD. SEE DRAWING(s)b. SHEATHING METHOD. SEE DRAWING(s)c. STANDING SEAM METAL ROOF. USE CLAMP OF CHOICE;ACE https://www.aceclamp.com/standing-seam-metal-roof-clampsS-5 https://s-5.com/products/roof-clamps/TRA http://trasnowandsun.com/product-category/solar-mounting/3. CONTRACTOR SHALL MAKE CLEAR TO AHJ WHICH INSTALLATION DETAILS WILL BEUSED, AND PROVIDE OEM DATA SHEETS, MANUALS OR OTHER INFO REQUIRED BY AHJ4. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE.110120130140150160170180Wade Nichols 6008 Tangelo Dr, Fort Pierce, FL 34982 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHERSS SERRATED T-BOLTSS SERRATED FLANGE NUTFLASHLOC BASE MILL OR DARK678"312"214"334"8. CONTRACTOR SHALL SUBMIT & ABIDE BY THE RAIL OEM INSTRUCTIONS.TYPICAL SHEETHING-ONLY, SELF-FLASHING,SOLAR ROOF ATTACHMENT WITH OPTIONAL REDUNDANT WATERPROOFING. APPEARANCE MAY VARY -DIM/SQR/RND/ETC.COMPLETED LO-SLOPE ATTACHMENT WITH OPTIONAL REDUNDANT WATERPROOF TARGET