HomeMy WebLinkAboutProduct Approval (2) l41141202+ Florida Building Code Online
0 ., • 0 0
BCIS Home-I Log In I UserRegistration Hot Topics Submit Surcharge Slats h Fads Publications .Contact-US: Sa s s'eta Map,] u.1
3:1 search
I
Product Approval
. � IR USER:Pu611cUser �/`�=� ,A_y�H.-�
Product Approval Menu>Product or Apgiicatlon Search>Application List
':. REVIEWED FOR.
Search Criteria ne S
C COMPLMNd earth
Code Version 2020 FL# LUCIE COMNT�ip
Application Type ALL Product Mau durer oprema, nc.(Canada)
Category ALL Subcategory OC C ALL
Application Status ALL Compliance Method ALL
Quality.Assuranee Entity ALL Quality Assurance Entity Contract Expired ALL r--
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL gggg�����•����ttti®®tttt
Search Results r AoDlicatIons. _
Ty,_e Manufacturor_ Validated ByStatus
F12569-1121 Revision Soprema,Inc.(Canada) John W.Knezevich,PE Approved
ljiston, ;Category:Roofing (954)772-6224
Subcategory:Undeflayments
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the PDC and/or the Commission If necessary.'-'
Contact Us::.26b1 Blair Slone Road.Tallahassee FL 32399.phone:850-987-1824
The State of Florida is an WEED employer.Cop ht 2007-2013 Mate of-Florida.::Prtvaty Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mall address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,Ikensees licensed under Chapter 455,F.S,must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click here
Product APprov�l ACCOp_fs%;
, ® eCtazt',®.
Credit Card
Safe
https://www.floridabuildlng.org/pr/pr_appjst.aspx 1/1
f �
9
NEMO etc.
Certificate ofAuthoriration#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Soprema,Inc: -- - — Evaluation Report S18010.06.09-R19
1640 rue Haggerty FL2569-R21
Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 19:12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 6111320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 71 Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof'Underiayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC,LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. .
ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMOI etc. Evaluated"may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its
entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by: "'a°��
Robert J.M.Nieminen,P.E. k��,a�A-`�Q r2 The facsimile seal appearingwas authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 s��,sF� �„?. Nieminen,P.E.on 12/16/2020.This does not serve as
yea MOO an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
®2019 NEMO ETC,LLC
O- NEMOletc.
RooRNG COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
with the following sections of the 7th Edition(2020)Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
set forth herein.
STANDARDS:2.
Section Proaerty - Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.12.2/R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Ent Examination Reference Date"
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.104-111 04/07/2010
ERD(TST6049) FRSA/TR104-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) S37210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) 543530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.143 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2024
ERD(TST6049) . ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/1)1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01 12/16/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2025
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
NEMO ETC,LLC Evaluation Report 518010.06.09-R39
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F12569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 2 of 9
i
NNEMO etc.
14. PRODUCT DESCRIPTION:
,._. .
Material ; 7 „ .
Product Plarit(s) Description
--.. .-
41 Lastobond TU HT ASTIVI D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 09-28 surfaced,SBS modified bitumen roof
underlayment
4.2 Tri-Built S/A HTTU j ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
Underlayment i FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.3 Lastobond Shield ASTM D3970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
f modified bitumen roof underlayment available in
I two widths;36 and_45 inch
4.4 I' RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced;SBS
modified bitumen roof underlayment
4.5 Lastobond Shield HT i ASTM D3970 VDrummondville,QC self-adhering,woven polyethylene surfaced,high
' temperature,SBS modified bitumen roof
_ underlayment
4'.6 Lastobond Pro HT-N ASTM D1970 I Drummondville,QC self-adhering,woven polyethylene sufficed,SBS
modified bitumen roof underlayment available In
two widths;36 and 45 inch
4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.8 Enviro5hield ASTM D3970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
- -- —_ _ underlayment
4.9 Lastobtnd 195 ASTM,D1970 Gulfport,MS self-adhering;glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
— _ -- - underlayment
4.11 Lastobond Eco ASTM 61976 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.12 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.13 Tri-Built Smooth HT S/A ASTM'D3970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.15 RESISTO L61236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.16 TRI-BUILTSand-RSA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle Underlayment Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
NEMO ETC,LLC
Evaluation Report 518010.06A9•R19
Certificate of Authorization N32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 3 of 9
S
it
MEMO etc..
Product Material Plant(s) Description
Standard
4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector ; Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER I Gulfport,MS surfaced,SBS modified bitumen roof
_ Wadsworth,OH underlayment
4.19 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.20 Colphene FR GR ASTM D6263 Gulfport,MS self adhering fiberglass reinforced,granule-
Wadsworth,OH surfaced,SBS modified bitumen roof
-- - underlayment
S. DMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Meminen,P.E.are,in any way,the-Designer--
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBCSecdon: ; 1 S07,2 1507.3 _ 1507.4&1507.5 _ 1507.7 15.07 8'&1507.9
Asphalt clay and Concrete Tnle -metal - _ _ Slate or
Underlayment Wood Shakes or
Mechanical Adhesive- Slate-Type Shingles Panels Shingles Shingles
Attach Set g Shingles
Lastobond TU HT,Tri-Built S/A HT TU Yes Yes
Underlayment Yes Yes See 5.6,1 Yes Yes Yes (Joint strips,1507.1.1.3/
- R905.LL3)
Lastobond Shield,Pro HT-N,RESISTO SA Yes No No No No Yes Yes
SMOOTH PLY 40 Uoint strips,3507.1.L3/
R905.M.3)
Yes
Lastobond Shield HT,Pro HT-S Yes No No Yes Yes Yes dam strips,15a7.1.1.3/
RMA.L3)
Yes
Enviro5hield Yes No No Yes Yes Yes (joint strips,1507.1.1.3/
R905,S.L3)
Lastobond Eaves Protection Sheet, Yes
Lastobond195 Yes No No No No Yes Vointstrlps,1507,LL3/
-- - R905.1.L3
NEMO ETC,LLC Evaluation Report S18010.06.09-R19
Certificate OJAutborization#32455 7TM EDITION(2020)FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 4 of 9
f
- - "NEM0 etc.
TABLE 1: ROOF COVER OPTIONS
_fBC;Mbn_; 13072 _` _ 15073 15074935073, 15D77 15078`8"35079.
day and Concrete 71ie , Metes -
Underlaymertt I Asphalt _ Slate or Wood Shakes or
Mechanical Adhesive- Slate-Type
I Shingles Attach
i Panels shingles Shln es Shingles
---- — — -
Lastobond ECO,RES1-STO LB1236,TRI-
BUILT Sand-R SA Shingle Underlayment,
1 Grip-Rite Eave&Valley Protector, Yes �' No No No No Yes Yes
TopShield ICE&WATER DEFENDER, ll , Uointstr�LL3) 3/
RESISTO LB1244
_ I
Lastoborid Smooth Seal HT,Tri-Built Yes
Smooth HT S/A Underlayment,Grip-Rite I' Yes 6 No No Yes Yes Yes Uoiet stri sso7.1.L3/
_Smooth Seal HT _� __ _ ; 119os.LL3)
Colphene FR GR Yes
Yes Yes No No No Yes
(J61d strips,ssm.1.13/
Rsos.i.L3) -
5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
j TABLE 1JU ALLOWABLE TILE ADHESIVE UNDERLAYMENT COMBINATIONS)
,Underlayment Adhesive _
FMrida Product Approval'
Lastobond TU HT,Tri-Built S/A Dupont Tiile Bond"'Roof Tile Adhesive"_ FL22525
HT TU Underlayment 'ICP Adhesives and Sealants"Polyset°AH-160" FL6332
5.7 Allowable Substrates:
TABLE2:SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS -. -
Substrates(designed to"meet wind loads:for project)
y, Underlayment Application, -
Type Primer Material(s)
i Lastobond Shield,Lastobond Pro (Optional)ASTM plywood,OSB or Southern Yellow Pine
HT N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick, (SYP)
40,Lastobond Shield HT, sheathing Elastocol St_i_c_k Zero
Lastobond Pro HT-S, ASTM D41 structural concrete
EnviroShield Lastobond TU HT -
(Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Underlayment,Lastobond Eaves
Protection Sheet,Lastobond 195, self-
Lastobond ECO,RESISTO LB3236, adhering
TRI-BUILT Sand-R SA Shingle
Underlayment,Grip-Rite Eave&
Valley Protector,TopShield ICE& Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modred Sopra-
WATER DEFENDER,RESISTO Stick Zero G
LB3244,Lastobond Smooth Seal
HT,Tri-Built Smooth HT S/A
Underlayment or Grip-Rite
Smooth Seal HT
Deck/ (Optional!ASTM Plywood
sheathing D41 -
self- ASTM D41 structural concrete
Colphene FR GR (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
adhering Insulation
St)ckZero Fiber Roof Board
I -
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
Stick Zero G
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,LLC Evaluation Report S18010.06A9-1119
Certificate OfAutharization#32455 7-EDITION 12020)FBC NON-HVHZ EVALUATION FL2S69-R21
Soprema Roof Underlayments Revision 19:12/iS/2020
Page 5 of 9
ONEMOletc.-_
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMEN73
Underlayment Application -
Substrates(designed to meet wind loads for project)
. ---- -- - -
Type Primer Matenal(s)_
Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO
LB1236,TRI-BUILT Sand-R SA self- Existing RESISTO EXTERIOR Existing sand-surfaced,glass-fiber surfaced,
Shingle Underlayment,Grip-Rite adhering substrate PRIMER mineral-surfaced or film-surfaced roof
Eave&Valley Protector or underlayment
TopShield ICE&WATER
DEFENDER
•Final acceptance of any existing substrate in a reroof(tear-offJ installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE&
WATER DEFENDER self-adhering underloyments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof A lications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HTTU Underlayment,self-adhered.
#2 -Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
NEMO ETC,LLC Evaluation Report S18030.05.09-R19
Certifrcote of Authorization 1132455 7TH EDITION(20Z0)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
OiNEMO' Ott
#3 Maximum Desikn-Pressure -120.0 psf.
Dick: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction ton of Authority
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment; Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#4 Maximum Desikn Pressure=-250.0 iii
Deck: Min.I5i32-ini:6 APA-rated BCX plywood(may be installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Bullt S/A HT TU Underlayment,self-adhered.
#5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of--45 psf.
5.8.3.2 Mechanically-Attached.Base-Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Arind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the
limitations set forth in Section 2.2,10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Desikn Pressure=-60.0 6sf
Deck: M 24nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
Inch o.c.at the 4-Inch laps and 6-Inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment
attachment shall be in accordance with the manufacturers installation instructions and attachment of the
Insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:,
TABLE 3: ExposuRE LIMITATIONS,
Underlayment 1,Prepared Roof. ii
,Cover Ma)dmm
Installation Type Exposure(days)
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,TRI Mechanically
BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,Topshield ICE attached 30
-&WATER DEFENDER or RESISTO LB1244
Lastobond TU HT,Tri-Built$/A HT TU Underlayment Adhesive-set the roof30
system
Lastobond Shield,Lastabond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Mechanically 90
attached
Underlayment or Grip-Rite Smooth Seal HT
Mechanically
Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR attached 180
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authalization 1132455 7-EDITION(2020)FBC NON-KVHZ EVALUATION FI.2%9-1121
Soprenia Roof Underlayments Revision 19:W35/2020
Page 7 of 9
*_ NEK40 etc.
5.10 Tile Slippage Limitations: When loading roof tiles an the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS _
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT,Tri- -;
Built S/A HT TU
Underlayment Lugged
Flat Max.10-tile stack 5:12
Colphene FR GR Lugged Max.10-tile stack 6:12
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment In a reroof(tear-off)application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the
AuthorityHaving Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
g
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 Lastobond TU HT, Tri-Suitt S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet,
Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment,Grip-Rite
Smooth Seal HT, RESISTO L81236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley
Protector,TopShield ICE&WATER DEFENDER,RESISTO LB1244 or Colphene FR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R90S.1.1.
NEMO ETC,LLC Evaluation Report S18030.06.09-1119
Certificate ojAuthorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8 of 9
ii
NEMO etc.
6.3.2 Tile-ADDlications:
limited to Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
Instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
BUILDING7. •
As required by the Building Offlcial or Authority Having Jurisdiction to properly evaluate the installation of this
product.
i8.
Contact the named CW entity fog manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALiTyAssuRANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.dI.con1
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certif sate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlaymertts Revision 19:12/25/2020
Page 9 of 9