Loading...
HomeMy WebLinkAboutRevisions; Extended Patio & Footing for Screen EnclosureOFFICE USE ONLY: DATE FILED: ``-- REVISION FEE: l� •� LOCATION/SITE ADDRESS: r, PERMIT # =00OZ - D q / RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 6 // LA) 00 TAILED DESCRIPTION OF PROJECT VISIONS: Glwr Go nt.✓ file / Lo �3 Qr�.u� �7 c,� CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC051145 BUSINESS NAME: GREW GHO Homes LLC QUALIFIERS NAME: William Handler ADDRESS: 590 NW Mercantile Place CITY: Pt St Lucie STATE: FL PHONE (DAYTIME): 772-773-0075 OWNER/BUILDER INFORMATION: NAME: GRBK GHO St Lucie LLC ADDRESS:590 NW Mercantile Place CITY: Port St Lucie STATE: FL PHONE (DAYTIME: 772-773-0075 ARCHITECT/ENGINEER INFORMATION: NAME: Donald J Nuelle ADDRESS: 11634 SW Rowena St CITY: Port St Lucie PHONE (DAYTIME): 561-629-6975 '0!2 .n 'e l . ST. LUCIE CO CERT. #: ZIP; 34986 FAX: 561-688-0909 ZIP: 34986 FAX: 561-688-0909 STATE: FL ZIP: 34987 FAX: N/A SLCCC: 9/23/09®� Revised 06/30/17 FILE COS GENERAL NOTES I. THIS PLANS WERE PREPARED USING THE 2017 FLORIDA BUILDING CODE 6TH EDITION 2. TYPE OF CONSTRUCTION: CLASS V, UNPROTECTED, GROUP R3 OCCUPANCY PER FLORIDA BUILDING CODE. 3. CONSTRUCTION SHALL FOLLOW THE FLORIDA BUILDING CODE AS ADAPTED BY THE COUNTY AND ALL APPLICABLE AMENDMENTS. 4. THESE PLANS, AS DRAWN AND NOTED, COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY. 5. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER STRIPPED. WINDOW UNITS SHALL DISPLAY LABELS SHOWING COMPLIANCE WITH THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY SECTION. 6. REGISTERED BAITING SYSTEM FOR TERMITE TREATMENT TO DE INSTALLED AND MONITERED BY THIRD PARTY PRIOR TO FINAL BUILDING APPROVAL PER F.B.C. 2017 ABBREVIATIONS ABV ABOVE EXT. EXTERIOR AFF ABOVE FINISHED FLOOR F.B.C. FLORIDA BUILDING CODE AHU AIR HANDLER UNIT F.R. FIRE RATED B.F. BI FOLD FIR FRENCH DOOR B.P. BI PASS FIN. FINISHED BLK. BLOCK FL FLOOR BLW BELOW G.T. GIRDER TRUSS BRIG. BEARING GA. GAUGE BTM. BOTTOM GALV. GALVANIZED CLG. CEILING GFI GROUND FAULTINTERRUPT CMU CONCRETE MASONRY UNITS GL GLASS COL COLUMN GWB GYPSUM WALLBOARD CONIC. CONCRETE GYP. BD. GYPSUM WALLBOARD CSMT. CASEMENT HOT. HEIGHT DBL DOUBLE HPS. HOOPS DIA DIAMETER HR HOUR DISP. DISPOSAL HS HORIZONTAL SLIDING DP DESIGN PRESSURE HVHZ HIGH VELOCITY HURRICANE ZONE DR. DOOR INS. INSULATION DW DISH WASHER INT. INTERIOR E.E. EACH END LG. LONG ELEC. ELECTRICAL UN, LINEN ELEV. ELEVATION LT. LIGHT E.S. EACH SIDE LT. LAUNDRY TUB MASONRY NOTES PLAN NOTES FRAMING NOTES ELECTRICAL NOTES 1. CONCRETE UNITS BE ASTM C ASTM GRADES NI OR NIT. PROVIDE THEIST R 0 PSI) LINTELS AS NECESSARY. (fm = 1500 PSI) 1. PROVIDE 1x2 P.T. FOTHER HORIZONTAL 0 CEILING WALL INTERSECTIONS OR 8'-0' 0/C 1. THE TRUSS LAYOUT SHOWN ON THIS SHEET IS SCHEMATIC IN NATURE. HOWEVER, THE 1. CONTRACTOR SHALL VERIFY WITH ELECTRIC PROVIDER THE LOCATION OF SERVICE AND MAX. AND ALL OTHER PER F.B.C. SECTION 718 C SUPPORTING SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THAT THE SHALL LOCATED METER & PANELS AS REQUIRED. THESE PLANS WERE PREPARED 2. MORTAR TYPE M PER ASTM C 270-92. Z FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. ALT. AND PARS 2 ALL GLAZING WITHIN 24° AND PARALLEL TO A DOOR SHALL BE TEMPERED. 2. ALL WIRE SHALL BE 7HHN COPPER, UNLESS NOTED OTHERWISE. USING THE 2017 FLORIDA BUILDING CODE 6th EDITION 3. CELLS, LINTELS AND BOND BEAMS WHERE SPECIFIED SHALL BE FILLED W/ 3000 PSI PEA ALL WINDOWS OR GLASS ENCLOSURES AT OR WITHIN 36' OF TUBS AND SHOWERS WTH SILLS 2. THIS FRAMING SCHEME (DIRECTION OF TRUSSES, MAJOR G.T. BEARING POINTS, ETC.) AN GRAVEL CONCRETE. LESS THAN 60" ABOVE FLOOR SHALL BE TEMPERED. ALL GLASS IN SIDELIGHTS, SUDING GLASS BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM THE PRIME PROFESSIONAL OF 3. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE DOORS AND FRENCH DOORS SHALL BE TEMPERED. RECORD WHO MUST REVIEW PROPOSED CHANGES AND AUTHORIZE STRUCTURAL REVISIONS COPPER OF EQUAL AMPACITY. i. REINFORCING: ACCORDINGLY. 3. EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS. 4. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED ABLE. VERTICAL: EGRESS WINDOWS SHALL HAVE A MINIMAL NET OPENING OF 24' HIGH, 20" WIDE, AND MIN. NET 3. FINAL SIGNED AND SEALED ENGINEERED TRUSS DESIGN MUST BE SUBMITTED TO THIS AREA OF 5.7 S.F. FOR 2nd FLOOR WINDOWS AND 5.0 S.F. FOR 1st FLOOR WINDOWS THE OFFICE FOR REVIEW. TRUSS DESIGNERS MUST PROVIDE ALL TRUSS CONNECTIONS AS PART OF 5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. A. ASTM A615-94 PER REINFORCING SECTION (GRADE 60). BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' ABOVE THE FLOOR. THE DESIGN. 6. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER B. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL GORE, IT SHALL NOT BE 4. TRUSS MANUFACTURER SHALL SUBMIT THREE (3) COPIES OF SHOP DRAWINGS AND SPECIFICATIONS. SLOPED MORE THAN ONE HORIZONTAL IN SIX VERTICAL AUGNMENT, EVEN THOUGH IT IS IN AN 4. IN AREAS OTHER THAN HVHZ TOED GLASS THICKNESS SHALL COMPLY WITH SECTION 2411 ENGINEERING CALCULATIONS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER, OF. ADJACENT CELL TO THE VERTICAL WALL REINFORCING. OF F.B,C. AS THE MINIMUM THICKNESS ALLOWED. THEIR ROOF TRUSS DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR ARCHITECTS REVIEW 7• PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS C. VERTICAL REINFORCING STEEL SHALL HAVE A MINIMUM CLEARANCE OF ONE-HALF INCH FROM 5, PROVIDE A MINIMUM OF 4" CLEAR ALL AROUND AIR HANDLER UNITS PRIOR TO FABRICATION. RENEW OF TRUSS SHOP DRAWINGS IS A COURTESY BY THE ARCHITECT AND IN NO WAY RELIEVES THE TRUSS MANUFACTURER OF HIS RESPONSIBILITY TO 8. PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIP. AND AT THE MASONRY. PROVIDE A LAYOUT THAT FULLY INTEGRATES NTH THE ARCHITECTS SUPERSTRUCTURE. IF PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER. 6. ALL DWELLING ROOMS MUST HAVE HVAC RETURNS. RETURNS MAY BE DUCTED, JUMPERS OR THERE IS ANY CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRUSS COMPANY SHALL RECOMMENDATIONS. M.C. MEDICINE CABINET SMS SHEET METAL SCREWS O. VERTICAL REINFORCING SHALL BE AS COATED ON THE PLAN AND AS INDICATED IN THE TRANSFER GRILLES NOTIFY THE ARCHITECT IN WRITING OF THE SPECIFIC AREAS OF CONCERN. M.R.H. MEAN ROOF HEIGHT ST. STIRRUPS COLUMN SCHEDULE 9. PROVIDE GFl BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS M.T. METAL THRESHOLD STL STEEL 7. A/C UNITS MAY HAVE CONIC. PAD OR OTHER APPROVED MATERIAL EXPENDING ABV. 5. TRUSSES TO BE DESIGNED TO CARRY LOADS OF ATTIC AHU AND MISC. EQUIPMENT. SHOWN ON PLANS. MAX. MAXIMUM SW SWITCH E VERTICAL REINFORCING EACH SIDE OF ANY OPENING, IF REQUIRED, SHALL BE CONTINUOUS ADJOINING GRADE OR SHALL BE SUSPENDED A MIN. OF 6" ABV. ADJOINING GRADE COORDINATE LOCATIONS WTH BUILDER PRIOR TO FABRICATION AND INDICATE ON TRUSS MFR. MANUFACTURER TEMP. TEMPERED TO THE TIE BEAM. PRECAST UNTELS SHALL HAVE OPENINGS TO ALLOW REINFORCING BARS TO DRAWINGS. 10. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS MICMICRO TEL THROUGH CONTINUE UNINTERRUPTED. /� SELECTED BY BUILDER. MICROWAVE T.O. THROUGH OUT BEAM SCHEDULE NOTES B. ALL INTERIOR LOAD BEARING PARTITIONS TO BE CONSTRUCTED WITH CUPS, TOP AND M.O. MASONRY OPENING T.O.B.B. TOP OF MASONRY BOND BEAM HORIZONTAL, BOTTOM EACH STUD, AS PER CODE. 11. PROVIDE PRE -WIRED TELEPHONE OUTLETS AS SHOWN ON PLAN. MONO. MTL MONOLITHIC METAL T.O.PL T.O.TB. TOP OF WOOD PLATE TOP OF TIE BEAM A. HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SCHEDULED IN THE BEAM SCHEDULE. 1. ALL COMPOSITE LINTEL MARK °L° TOP BARS SHALL BE CONTINUOUS UNLESS OTHERWISE NOTED ( ) 7. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE 'TIMBER CONSTRUCTION 11 PROVIDE PRE- WIRED T.V. OUTLETS FOR ABLE AS SHOWN ON PLANS. O.H.D. 0/C OVER HEAD DOOR ON CENTER U.N. U.N.O. TYPICAL UNLESS NOTED OTHERWISE 5. GENERAL 'BB' MANUAL' AS PUBLISHED BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION. 13. DEDICATED CIRCUITS SHALL HAVE NO MORE THEN 6 DUPLEX RECEPTACLES. P.L.F. POUNDS PER UNEAR FOOT UL V.I.F. UNDERWRITERS LABORATORIES VERIFY IN FIELD A. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530-05J ASCE.8. 2. ALL BOND BEAMS (MARK REINFORCING SHALL BE CONTINUOUS THROUGH BOND BEAMS ONLY. ALL SPLICES TO BE A MINIMUM OF 48 BAR DIAMETERS. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. 14. IN KITCHENS, DINING ROOMS AND BATHROOMS, RECEPTACLE OUTLETS FOR COUNTER P.S.F. P.S.I. POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH W.A. WEDGE ANCHORS 7-10/11A.S. 402-05, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER SPACES SHALL BE GFCI PROTECTED ACCORDING TO NEC 210-8( a ). P.T. PRESSURE TREATED W/ WITH COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. 3. BOND BEAM SCHEDULE DEPTHS ARE MINIMUM AND MAY BE INCREASED 8' TO FIT BLOCK CEMENTITOUS MATERIALS AND THE WOOD AS PER CODE. PART'N, PARTITION WC WD• WATER CLOSET WOOD B. CONSTRUCTION SHALL BE IN ACCORDANCE WTH A.C.I. 530.1-05/A.S.C.E. 7-10/T.M.S. 602- WORK. 9. CARPENTER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND BRIDGING USED 15. ALL CLOSET LIGHTING SHELL COMPLY WITH NEC SEC. 410.8. PKT PLYWI. POCKET PLYWOOD 05, SPECIFICATIONS FOR MASONRY STRUCTURES AND THE COMMENTARY ON SPECIFICATIONS 4. REFER TO CONCRETE NOTES FOR INFORMATION ON CONCRETE AND STEEL SPECIFICATIONS. DURING ERECTION OF TRUSSES TO PREVENT COLLAPSE OR DAMAGE. 16. SMOKE DETECTORS SHALL BE CONNECTED TO KITCHEN OR BATH LIGHTING CIRCUITS R.O. ROUGH OPENING FOR MASONRY STRUCTURES. 10. HEADERS FOR FRAMED OPENINGS GREATER THAN 6'-0' MUST BE ENGINEERED AND AHEAD OF SWITCH AND HAVE SELF CONTAINED BATTERY BACK-UP. DETECTORS SHALL BE SOLD GLASS 6. VERTICAL CELLS FOR MASONRY TO BE GROUTED SHALL HAVE VERTICAL ALIGNMENT CONCRETE NOTES STAMPED BY THE TRUSS MANUFACTURER. (UNLESS NOTED OTHERWISE) TANDEM WIRED SO ALL DETECTORS SOUND SIMULTANEOUSLY. SS.C. .G.D. SF SLIDING DOOR SQUARE FOOT SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED CONT. CELL 17. PREWIRE FOR GARAGE DOOR OPENER SENSOR. SH SINGLE HUNG 11. ALL HEADERS OVER DOORS AND WINDOWS TO BE (2) OR (3) 2X12'S UNLESS OTHERWISE 7. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF GROUTED CELLS AT EACH 1. CONCRETE SHALL CONFORM TO ASTM C94-94 AND SHALL HAVE STRENGTH IN 28 DAYS AS NOTED. (FOR WOOD FRAME CONSTRUCTION DEPENDING ON ALL WALL THICKNESS). 18. ARC FAULT -INTERRUPTER PROTECTION PER NEC 210.11 REQUIRED FOR ALL 120-VOLT, LIFT OVER 4'-0' HIGH CLEANOUTS SHALL DE SEALED AFTER CLEANING AND INSPECTION AND SPECIFIED IN THE FOUNDATION AND MASONRY NOTES (UNLESS NOTED OTHERWISE) ALL SINGLE PHASE 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS DWELLING UNITS SAINT LUCIE COUNTY PRODUCT APPROVAL OPENING SCHEDULE: OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS OPEN ID PRODUCTMODEL # MANUF. GLASS ATTACH. METHOD TYPE SIZE, SPACING BUILDING DESIGN PRODUCT DESIGN DESCRIPTION AND EMBED. *FILL ALL MANUF. HOLES PRESSURE PRESSURE A FL-9174.10 R12 9100 OHD 16080 WAYNE DICTION N/A W/ 1-1/4' WASHER & 2-3/4' MIN. EMBED. D•P: +28.5 PSF +39.2 PSF -43.7 PSF 2-3/4' MIN. EDGE DISTANCE. 6" FROM END -34.8 PSF B FL 17499.1 (2) SH 26 MI WINDOWS & DRS SGL IMPACT 3/ C TAPCONS W/ 1-1/4' MIN EMBED D.P. +29.9 PSF +55.0 PSF -55.0 PSF 0 0 M C FL-20468.11 SGL LITE 3080 THERMA TRU SGL IMPACT 1/4" TAPCONS W/ 1-1/4' MIN. EMBED CORNERS 0 D.P= +31.9 PSF 50.0 PSF -50.0 PSF DR W/ SIDELITE 4- & 14.5- O/C MAX. SPACING. -34.B PSF 1 .5 4625 ARCHED FG MI WINDOWS & ORS SGL IMPACT 3 T / - / IN BE .: 3. EQUAL SPACING & 3' FROM EDGE -36.3 PSF E FL 17499.1 (2) SH 26 MI WINDOWS & DRS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P = +29.9 PSF +55.0 PSF -55.0 PSF 0 10" O/C MAX SPACING & 2- FROM EDGE -32.8 PSF F FL 15349.5 3020 TRANSOM MI WINDOWS & DRS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF EQUAL SPACING & 3' FROM EDGE -36.3 PSF G FL 15349.5 3020 TRANSOM MI WINDOWS & DRS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF EQUAL SPACING & 3' FROM EDGE -36.3 PSF H FL 17499.1 SH H33 MI WINDOWS & DRS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF 01C' O/C MAX SPACING & 2' FROM EDGE -36.3 PSF FL 17499.1 SH 35 MI WINDOWS & DRS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 010' O/C MAX SPACING & 2' FROM EDGE -34.8 PSF J FL 22401.3 12080 SGD MI WINDOWS & DRS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +28.5 PSF +MO PSF -55.0 PSF 0If C/C MAX SPACING -31.3 PSF K FL 17499.1 (2) SH 35 MI WINDOWS & DRS SGL IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P: +29.9 PSF +55.0 PSF -55.0 PSF 01U' O/C MAX SPACING & 2" FROM EDGE -32.B PSF L FL 17499.1 SH H33 MI WINDOWS & DRS SGL IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX SPACING & 2- FROM EDGE -41.5 PSF M FL 17499.1 SH 25 MI WINDOWS & ORS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 16- O/C MAX SPACING & 2- FROM EDGE -34.8 PSF N FL 17499A SH 25 MI WINDOWS & DRS SGL IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +5&0 PSF -55.0 PSF 0 10' O/C MAX SPACING & 2- FROM EDGE -34.8 PSF 0 FL 174B9.1 SH H33 MI WINDOWS & DRS SGL IMPACT 3/16- TAPCONS W/ 1-1/4' MIN EMBED D.P= +33.5 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX SPACING & 2- FROM EDGE -36.3 PSF P FL 17499.1 SH 26 MI WINDOWS &DRS SGL IMPACT 3/16" TAPCONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 10" O/C MAX SPACING & 2' FROM EDGE -34.8 PSF PRODUCT MODEL MANUF. ATTACHMENT METHOD BUILDING DESIGN PRODUCT DESIGN TYPE, SIZE, SPACING, EMBED., STIFFENERS, ETC PRESSURE PRESSURE MULLIONS MAX. 104-1J4' HORIZ MI WINDOWS & DOORS 1/4' TAPCONS WJ 1-1/4' MIN EMBED (4) FASTENERS PER CUP TOP & BTM. 37.7 PSF 54.0 PSF -54.0 PSF FL 15353.4 ROOFING NOA NO. 18-0829.05 EAGLE ROOFING (2) 10d RING SHANK NAILS -83.4 psf -172 psf. BEL-AIR CONCRETE TILE PRODUCTS ROOFING FL 5374-R5 EAST COAST 3M 2 COMPONENT FOAM ROOF TILE ADHESIVE AH-160 -83.4 psf -169 psf. HIP AND RIDGE CHANNEL METAL METALS, INC UNDERLAYMENT NOA NO. 17-0614-.22 POLYGLASS USA PLIES NAILS AND TIN CAPS 12' GRID, 6' O.C. AT A MIN. 4' N/A N/A PEEL & STICK SBS UNDERLAYMENT INC. HEAD LAP SIDING STUCCO N/A N/A N/A N/A 2 RING SHANK ATTACHED TO UNDERSIDE OF TRUSS SOFFIT STUCCO N/A SPACED 0 EVERY HI RIB (4' 0/C) W/ 1-31C EMBED. N/A N/A PER MAIL BEFORE GROUTING. CONCRETE WORK SHALL BE IN ACCORDANCE NTH ACI 310-11 AND ACI 301-05. ALL 12. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE. NO. 2 OR BETTER AND SHALL PROVIDE CONCRETE MASONRY WORK SHALL BE IN ACCORDANCE WITH ACI 530-11. ALLOWABLE STRESS VALUES OF 1200 PSI IN BENDING FOR A SINGLE MEMBER USES 90 PSI 19. CARBON MONOXIDE DETECTORS REQUIRED WITHIN 10' OF ANY SLEEPING ROOM. FOUNDATION NOTES 2. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE SLABS ON VAPOR BARRIER - IN HORIZONTAL SHEAR AND SHALL HAVE A DOG ELASTICITY OF 1600 K51 OR BETTER, AS DETERMINED BY AN APPROVED LUMBER GRADING AGENCY. AG 3/4- BEAMS AND COLUMNS - 1 1/2- FORMED CONCRETE BELOW GRADE-2- UNFORMED PLUMBING NOTES 1. FLOOR SLAB TO BE 4" THICK POURED CONCRETE SLAB WITH FIBERMESH CONCRETE BELOW GRADE-3" 13. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 2x4 0 24" O.C. ON 0.006 VISQUEEN (OR EQUAL) ON CLEAN WELL COMPACTED FILL STUDS WITH 1/2- GYPSUM DRYWALL EACH SIDE. ATTACH DRYWALL WITH 1- LONG 3. REINFORCING STEEL GRADE 60 (FY=60.000) ASTM A615-94. BUGLE HEAD DRYWALL SCREWS AT 12" O/C MAX. 1. ALL PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 405, F.B.C. 1 ALL REINFORCING STEEL TO BE GRADE 60. 4. DETAIL OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WTH "THE MANUAL OF 14. METAL LATH OVER SHEATHING SHALL BE 3/8' V-GROVE OR DIMPLED. FASTEN TO 2. ALL PLUMBING FIXTURES SHALL MEET THE REQUIREMENTS OF TABLE 604.3, F.B.C. STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION" AS PUBUSHED BY THE SUBSTRATE AT 4" O/C AS FOLLOWS; 3. COLUMN AND WALL CENTERLINES SHALL COINCIDE WITH FOOTING CENTERLINES UNLESS CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERWISE. CONCRETE: 3/4" LONG STUB NAILS W/ 3/8' HEAD. HORIZONTAL AND VERTICAL WOOD 3. DISPOSITION OF RAIN WATER SHALL COMPLY NTH F.B.0 PLUMBING CODE CHAPTER 11. OTHERWISE NOTED. FRAMING MEMBERS W/ NAILS OR STAPLES TO PROVIDE AT LEAST 1-3/4" PENETRATION 4. FOOTING DESIGN BASED ON ASSUMED SOIL BEARING CAPACITY DE 2500 P.S.F., 5. ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY SUPPORT ALL LOADS DURING CONSTRUCTION /" INTO HORIZONTAL WOOD FRAMING MEMBERS, AND 3 4 PENETRATION INTO VERTICAL WOOD 4. ALL PLUMBING PENETRATIONS MUST BE A MINIMUM 10'-0' FROM ROOF JACKS. . FRAMING MEMBERS ON VERTICAL WOOD FRAMING MEMBERS, COMMON NAILS SHALL BE 5. FILL PLACED WITHIN 5'-T OF THE CONSTRUCTION PERIMETER SHALL CONSIST OF CLEAN 6. CONCRETE BEAM SIZES MAY INCREASED (8' MAX.) AS REQUIRED FOR ARCHITECTURAL BENT OVER TO ENGAGE AT LEAST THREE STRANDS OF LATH, OR BE BENT OVER A RIB 5. CONDENSATE DRAINS MUST BE A MINIMUM OF 12' OFF THE BUILDING. WELL GRADED SAND COMPACTED TO ACHIEVE A DETAILS OR FIT BLOCK COURSING, DROP BOTTOM OF TIE BEAM AS REQUIRED AT WINDOW AND WHEN RIB LATH IS INSTALLED. SHEATHING: 14 GAUGE STAPLES 1' LEG, 7/16' CROWN METAL MTL FRAMING SELF TAPING SCREWS /12 x 1/2' WASHER HEAD STAPLES SHALL NOT BE 6. INSTALL CHASE PIPE FOR HVAC. MINIMUM OF 95X MODIFIED PROCTOR ASTM D 1557. DOOR BEAMS (28- MAX.) AND ADD 2-#5 BARS BOTTOM IF DROP EXCEEDS 8. 6. ALL MONOLITHIC FOOTINGS HAVE BEEN CHECKED TO PREVENT THE USE OF TRANSFER REINFORCEMENT AT PERIMETER. RATIONAL ANALYSIS SHALL BE SUBMITTED, BUT ONLY IF 7. DOWELS COLUMN AND WALL REINFORCING TO FOOTING WITH SAME SIZE AND NUMBER OF DOWELS AS VERTICAL BARS ABOVE USED FOR SOFFITS OR CEILINGS 15. PNEUMATIC FASTENERS SYSTEM TO BE HILT -COL NAIL PROGRAM. TYPE TO BE CRF TIRO MECHANICAL NOTES REQUESTED BY THE BUILDING OFFICIAL 1-1/2" LONG AND .120' DIAMETER U.N.O. 7. CONCRETE FOR FOUNDATIONS AND FOOTINGS SHALL BE 25DD PSI MIN. 8. REINFORCING STEEL SHALL BE LAPPED 48 BAR DIA. MIN. WHERE SPLICED AND SHALL BE WIRED TOGETHER. PROVIDE CORNER BARS SAME SIZE AND NUMBER AS HORIZ BEAM 16. TRUSS MANUFACTURER SHALL DESIGN TRUSSES TO COMPLY WITH ALL SUPERIMPOSED 1. ALL HEATING, AIR CONDITIONING, REFRIGERATION AND VENTILATION EQUIPMENT SHALL 8. DAMAGE PROBABILITIES FROM TERMITE INFESTATION IS VERY HEAVY PER TABLE R301.2(1). REINFORCING AT EACH FACE LAP 48 BAR DIA. MIN. WIND LOADS PER F.B.C. 2017 STH EDITION & ASCE 7-10. CONFORM TO THE REQUIREMENTS SET FORTH IN THE *FLORIDA BUILDING CODE MECHANICAL" AND CHAPTER 28 OF THE FLORIDA BUILDING CODE. 9. PLACING DRAWINGS ON BAR LISTS SHALL CONFORM TO ACI'S 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE CONSTRUCTION AS PUBLISHED BY THE STEEL NOTES GARAGE NOTES CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERWISE. 10. DAMAGE PROBABILITIES FROM WEATHERING IS NEGLIGIBLE PER FBC TABLE R301.2(1). 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC 'SPECIFICATION FOR THE DESIGN, 1. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD PROPOSED SINGLE FAMILY RESIDENCE BY: 00 J11-1 Mw Ii RENTON JEM LOT 01 MEADOWOOD COPYRIGHT 2015 N1111--jil N 1 1 I IIL__jIILul LLJ 18�" 36" 52d" 25}' SH 15 SH 25 SH 35 SH H35 ■ ■ ■ ■ In ■ ■ ■ M.O. 20 1/8" M.O. 38' M.O. 54 1/8' M.O. 27 1/2" 1x, 2x, OR 5/4 BOARD 1x, 2x, OR 5/4 BOARD P.T. WOOD BUCK P.T. WOOD BUCK 38° 70" 38" , ®® l SH 35 3, "� /TYP. BAY WINDOW FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" 2005 EDITION. MATERIALS DOORS NOT LESS THAN J' (35 1 THICK, MUD OR HONEYCOMB CORE STEEL DOORS NOT SHALL CONFORM TO THE APPUCABLE ASTM SPECIFICATION AS FOLLOWS: SHAPES, PLATES A-3f LESS THAN j" (35 MIM) THICK, OR 20-MINUTE FIRE -RATED DOORS BOLTS - A 307-00 TUBULAR - A500-010 GRADE B (42 KSI) 2 DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE 2. WELDED CONSTRUCTION SHALL CONFORM TO THE AMERICAN WELDING SOCIETY "STRUCTURAL DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 AGE (0.48 MM) WELDING CODE". ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE A.W.S. A5.1 E70XX SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 3. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LOAD SCHEDULE LESS THAN a (12.7 MM) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. LOCATION LYE DEBT PART'N TOTAL GROUND FLOOR 40 50 10 100 SECOND FLOOR 40 15 10 65 ROOF 30 18 0 48 ATTIC 20 10 0 30 WIND: ULTIMATE ONO SPEED = 160 m.p.h. BUILDING RISK CATEGORY = II BUILDING DESIGN AS ENCLOSED EXPOSURE = C ROOF DEAD LOAD FOR WIND DESIGN TAKEN AT 10 p.s.E NQjEL THIS STRUCTURE IS DESIGNED IN ACCORDANCE WITH CHAPTER 16 OF THE FLORIDA BUILDING CODE AND ASCE 7-10. DESIGN PRESSURES FOR EXTERIOR DOORS AND WINDOWS ARE NOTED ON THE ELEVATIONS. WINDOW AND DOOR MANUFACTURERS SHALL MULTIPLY THE GIVEN DESIGN PRESSURES BY THE APPROPRIATE FACTORS TO OBTAIN TEST PRESSURES. THERMA TRU EXTERIOR DOORS Lw I Lw 2x P.T. WOOD BUCK SHOWN TYP. 7m, ml so M.O. 35 1/4' W M.O. 37 1/4' W M.O. 41 1/4- W M.O. 55 1/2" W M.O. 78 1/2" W X 99'H X9VH X99'H X99'H X99"H EDGE OF SLAB EDGE OF SLAB EDGE OF SLAB EDGE OF SLAB I T EDGE OF SLAB 2680 EXT DR 2880 EXT DR 3080 EXT DR 3080 EXT DR W/ 14" SIDELITE PR 3080 DR (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) DOOR INSTALLATION NOTE: DOOR BUCKS USED MAY BE 2s6, 5/4" BOARD OR 14. CONCRETE SCREWS USED TO SECURE THE DOOR FRAMES TO THE OPENINGS MAY BE ANGLED SLIGHTLY WITHOUT APPRECIABLE LOSS IN RESISTANCE. ALL FASTENERS SHALL BE OF THE SIZE, LENGTH AND SPACING AS REQUIRED IN THE PRODUCT APPROVAL INSTALLATION PROCEDURES DRAWING INDEX C-1 COVER SHEET A-1 FOUNDATION PLAN A-2 FLOOR PLAN A-3 ELEVATIONS A-4 SECTIONS A-5 STRUCTURAL PLAN A-6 TRUSS PLAN E-1 ELECTRICAL PLAN M-1 MECHANICAL PLAN PROJECT LOG ISSUED FOR START 10-02-19 ISSUED FOR PERMIT 11-01-19 BLDR. REV. 01.30.20 BLDG COMMENTS 03-11-20 TRUSS CONNECTOR REVISION 09-10-20 BUYER CHANGES REVS 09-21-20 a 0 w J ILL] N CP °. J w 3 OQ' _ LL W LU 7 N U LL z 0 /r N O c° a ++ w p� In fo O C CINL C + T 5c N o v � /a NHS O-tv L +L C Ora C aL+ 3 C 7 3 vi O C In CT �+ c � v v E CL = O m ICo i O a.-. N .Z"' U E O p LU i O y O O) (J C O � Cr = a> 2 c 3 F- O cn IM c pC7 vi N 0 Q ]L aEg Z � � n a� aA is `rLu • a .. • • SYMBOLS LEGENDS 1 DETAIL 4 DWG. 2 INTERIOR _,rg _ Q..;, SCALE O ELEVATION CJ� Air- 3 Q �+ E C # DETAIL on S ALE C COLUMN LABEL G5 " �, ^C FOOTING LABEL v�l SECTION Fi1i `` _ oWG. SCALE e► POT SHELF HEIGHT AS NOTED GT� SECTION DROPPED SOFFIT HEIGHT AS NOTED P�-1 LL ARCHED oMG. SALE TT IP'70I�� 1 - 1 LUL PLAN OR ELEV. SEE 0 ` z � IREOR ELEV.MASONRY CONSTRUCTION Q 0 SCALTYPICAL WWW O U GROUT FILLED CELL SEE O Lu 8� BEAM LABEL ■■ FOUNDATION PLAN .--1 3: 1"'y 0 o v QREVISION NON -BEARING FRAME 1 Q CONSTRUCTION NLJ..I I 1 BEARING FRAME ELn O DNORTH ARROW CONSTRUCTION 1/4" = P-0" U.N.O. - BREAK LINE In Fy.ELEV BEAM HEIGHT CHANGE ��� � COVER SHEET scAF if77' GRAPHIC SCALE 0'-0FIN. FL SLAB FLOOR ELEVATION I � C.1 �`��'° Mw - 01 I 5 FIBERMESH OR WELDED WIRE MESH SEE FOUN. NOTES FOOTING REBAR SEE FOOTING SCHED. •.•A.. w a N )R W.W.M. 1-15 CONT. 3' MIN. COVER 1 34 THICKENED EDGE #1 COLUMN MATCHING DOWELS SC GRADE lam. 48 BAR DIA. MIN. W/STD. NOOKS TYP, EXTERIOR CONT. A. w 1 MONOLITHIC FOOTING MATCHING DOWELS FOR MNS 48 BAR DIA.W/STD. HOOKS PAD REBAR Eq. EQ. SEE FOOTING SCHEDULE EDGE BARS ALWAYS SEE CHER REMAIN. SPACE 07HERS EQUALLY ISOLATED PAD 'B 4ON;LY(2) MATCHINGDOWELSFOR COLUMNS 48 BAR DIA. FIBERMESH FIBERMESH OR MIN. W/SID. HOOKS OR W.W.M. WELDED WIRE PAD REBAR ING REBAR MESH (SEE i SEE FOOTING SCHED. FOOTNG SCHED. SCHEDULE) EDGE BARS ALWAYS CENTER BAR WHEN II REMAIN. SPACE Y (2) REGO. 1 t 07HERS EQUALLY. EXT. CONT. MONOLITHIC- •. 1 ,A.�.. FUTURE FASTENERS BY SCREEN SCREEN MFGR. ENCLOSURE BY SCREEN PAVERS IN SAND CONTRACTOR BY OTHERS r1112:ICaul�mmams 8' x 8" CONT CONIC. FTG. REINFORCE W/ qpw 115 CONT. 59 SCREEN ENCLOSURE FTG. DETAIL MASONRY WALL BEYOND PAVER RECESS CONC. BRICK PAVER SET IN SAND SLOPE PER SURVEY FOOTING SEE SCHEDULE S4F3�E3�F.�� �f�...... SEE 07HER EQ.EQ.DETAILS FOR SEE 9E' F0071NG BEYONDXT. MONOLITHIC AT PAD WOOD POST, RBERMESH OR SEE FRAMING PLAN WELDED WIRE MESH PAD REBAR SEE FOORNG SCHED. EDGE BARS ALWAYS REMAIN. SPACE OTHERS EQUALLY. e.. SEE SCHEDUL b ) IN . MONOLITHIC OVERHEAD GARAGE OHD RECESS 20' DRIVEWAY / GARAGE INTERSECTION CONC. POURED FILLED CELL W/ STL. PER PLf DOWELL & EPDXY (1) #5 REBAR INTO SLAB FILLED CELL LOCATION IN 4" MIN. EMBED. INTO SLP 48 BAR DIA. SPLICE �— 8'x8' PRECAST LINTEL. SEE LINTEL SHOP DWGS A FILL COLUMNS fI AND LINTEL SOLID W/ GROUT Al 8'x8' FILLED CELLS W/ 1�5 WERT. (TIP.) TYPICAL DETAIL LINTEL ON COLUMN 48 BAR DIA. SPLICE 7.,, SEE BEAM SCHEDULE FOR REINFORCEMENT FILL COLUMNS SOLID , \--8'x8' FILLED CELLS W/ PEA GRAVEL CONCRETE SEE PLAN AND COLUMN SCHEDULE FOR REINF. TYPICAL DETAIL BEAM HEIGHT CHANGE I'. MISSED MN STL DEfAI REVISION TYP. HOLLOW MASONRY BLOCK RUNNING BOND PER PLAN 'ONC. SLAB & AONOLITHIC rOUNDATION PER PLAN FOOTING SCHEDULE MARK SIZE (WxD) REINFORCING DESCRIPTION DETAIL NO. F-1 20' x 18' X CONT. WA 15 CONT. EXTERIOR MONOLITHIC I F-2 20' x 184 X CONT. 2 i5 CONT. W/ EXTERIOR MONOL17HIC M RECESS 38 F-3 2'4' x 2'-6' x 12' W/3 15 EW. 8At PAD 0INTERIOR WOOD POST 6 4'-6' x 3'-0" x 12' W/4 15 E W. BRI. ISOLATED PAD 7 3'-6' x 1'-8' x 12' W/3 15 E.W. BTU. MONOL17NIC 0 PAD 19 LF-6 2'-6' x 3'-0' x 12" W/3 15 E.W. BTM. MONOL17HIC 0 PAD 19 THICKENED EDGE 7E-2 1 8' X 8' x CONT. W/115 CONT. THICKENED EDGE AT SCREEN ENCLOSURE 59 COLUMN SCHEDULE MARK SIZE TYPE DESCRIPTION C-1 8x8 BLOCK CONC. BLK. W/ 1 FULLY GROUTED CELL W/1-15 VERT, AT 6'-0' 0/C MAX. AND AT EVERY CORNER AND BOTH SIDES OF ANY OPENING MORE THAN 6'-O' WIDE C-2 BAB BLOCK CONC. BLOCK W/2 FULLY GROUTED CELLS W/l-15 VERT. EACH CELL AS LOCATED ON PLANS C-3 IRREGULAR BLOCK 45' M17ERED CONC. BLOCK IN FULLY GROUTED CELLS W/ 2-15 VERT. C-4 4740 WOOD POST PROVIDE BASE AND CAP AS NOTED ON DETAILS A4 PROJECT LOG ISSUED FOR START 10-02-19 ISSUED FOR PERMIT 11-01-19 BLDR. REV. 01-30-20 BLDG COMMENTS 03-I1-20 TRUSS CONNECTOR REVISION 09-10-20 BUYER CHANGES REVS 09-21-20 W W J � J W ale 3 W Z w z O u w Z W D N J a N Z 0 � r a co to O m N � L -0 cc > =o m fl o 0 o o, �0In C7 3 ui cn -o, .9 mgcc .� L U N OC mlou B -p w L ro =�D a�Juuzr €lao a aL o c E w c �E0 _ a�i Z � �v t 0 a C �/t cn o W r_ cc G 06 Q .0 0 ca U 2 6 C :7 �G ' r.. Lo N o LL_ 0 0 u ,—I o 1u U O � J Lu i (n 1/4" = V-0" U.N.O. FOUNDATION PLAN A-1 .d mw 01 DRYER VENT DRYER VENT LOCATION FRONT VIEW 6'-6' 0 ,2" AC CONC. PAD DETAIL N.T.S. FINISHED CEILING 2x WD BLOCKIN EACH SIDE OF I FOR MOUNTING 2x MTL STUD! TYP. FINISHED FLOOR TYP. MEDICINE CABINET (2) PO S.M.S. TOP & BOTTOM 0 EACH STUD FINISHED CEILING - SEE TYR. WALL SECTION 2x6 BLOCKING CABINET LOCATIONS. FASTEN EA. END 70 STUDS W/ (2) 110 S.M.S. EA. END 25 GAUGE CHANNEL SHAPED STUDS- (2X4 STUDS ® 16' 0/C) (2x6 STUDS 24. 0/C) W/1 FULL LENGTH LAYER OF 1/2" TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1° LONG BUGLE HEAD SCREWS 70 EACH SIDE 0 12° 0/C CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM CONC. FLOOR SLAB HIL77 PINS .145" DIA x 1' LG. 0 16" 0/C W/ 1" WASHERS TYPICAL INTERIOR PARTITION ALONG CABINETRY BACKING SCALE 3/40 = I'D- ALL CEILING AND WALL FINISHES SUCH AS PAINT SHALL COMPLY WITH FBC R302.9.2 AND BE LESS THAN THE VALUE OF 200. GARAGE CEILING 2x4 STUDS GARAGE FLOOR ELECT. PANEL / CHASE CALCULATIONS TOTAL U/A 2,503 S.F. COVERED ENTRY 55 S.F. COVERED LANAI 168 S.F. GARAGE 661 S.F. TOTAL AREA 3,387 S.F. CEILING 16" TYPICAL FRAMING ® 16" O.C. � az EL O ( L� N I I LLJ FINISHED FLOOR w In 0 =w I En L) � Of 0 It L� SOAP NICHE (2) 110 S.M.S. TOP & BOTTOM ® EACH STUD FINISHED CEILING - SEE TYP. WALL SECTION CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM W/ (1) #10 SMS 0 24° 0 25 GAUGE CHANNEL SHAPED STUDS 24° O/C W/1 FULL LENGTH LAYER OF 1/2' TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12" O/C CONC. FLOOR SLAB HIL77 PINS .145' DIA x 10 LG 0 16' 0/C W/ 10 WASHERS INTERIOR PARTITION .2 3/4" = V-0" -. PROJECT LOG ISSUED FOR START 1D-02-19 ALL SHELVING IN CLOSETS AND A4 so'_a• ISSUED FOR PERMIT 11-01-19 • BLDR. REV. O1.30-20 PANTRY TO BE OPEN SLAT WOOD SHELVING 15 B 16 0" 26-a° BLDG COMMENTS D3.11-20 T-10° T-1 16'-0° -4° 6'-8" 19'-8" 3 TRUSS CONNECTOR REVISION 09-10-20 I o 10'-8• T.O. B. 4 BUYER CHANGES REVS 09-21-20 t0'-8' To. . 0 9'-4" T.D.B. . O EXTENDED PAVERS SCREEN ENCLOSUR 'A 19'LO" ( GRE S) I I n e R-40 BLOWN -IN FIBER GLASS INSULATION AT ALL A/C AREAS ALL INSULATION SHALL COMPLY WITH FBC R302.10 FLAME SPREAD COMPLIANCE 25. SMOKE DEVELOPED INDEX 50. ADDITIONAL NOTES, 1. STANDARD HOLLOW CORE RAISED PANEL DOORS. 2. TILE TO 7'-0" IN MASTER SHOWER AND 7'-08 IN OTHER LOCATIONS. 3. FIBERGLASS BOARD OR DUR-O-ROCK TO 7'-0" A.F.F. OR SOFFIT AROUND TUBS/SHOWERS AND TO 4'-0' A.F.F. M MARBLE TUBS 4. ROUNDED CORNERS AT ALL LOCATIONS EXCEPT CLOSETS, SLIDERS, WINDOWS, DOORS, VERTICAL EDGES OF CEILINGS OR AS NOTED ON PLANS. 5. KNOCKDOWN CEILING TEXTURE AND MANGE PEEL WALL TEXTURE. 6. R-40 BLOWN -IN INSULATION AT ALL A/C AREAS 7. IMPACT WINDOWS. IMPACT / LOW E GLAZING AT WINDOWS AND SLIDING GLASS DOORS U VALUE SHGC IMPACT .62 / .25 TOTAL AIR VOLUME CUBIC FEET = 23277.9 TYP. WINDOW VERTICAL HEIGHT SEPARATION IS 8" 14 8' 14'-4' O (2) SH 35 — —— — — — — 9�-11' W-5 12- 1 1/ 13'-4° a^UNENr z W ■O 2-42'-4° PAVERSto BT COVER D m ° 9' 4° C • I MASTER I LANAI NOOK _. Q I 1 6 SUITE 10'-8° CL . CROWN 2880 14 � 9'-4° CLG. I 1'-7" I O (ABV MAINS B) ■ e I^ CRO ¢ N GLASHELF ■ •• 48- A.F.F. I 12080 SGD (3 PANELS) 4--4° M a 2 00 p \ / ' \ i'I I I �r®o a ¢ I QI SUPER KITCHEN ACKAGEIg BEDROOM 3 0 L — — — — — � i SOAP DISPENSER KITCHEN NVENIEN E PACKAGE r �nl�i 9'- " LG.� i • — 0D ¢m ISL � 4 • 21'-2" I m 1'-8• - ' ® 12'-0' T HEIR. a. 01 o 2680 2680 I I = �I ° 5080 BP.-, Z ■ HIS n Q �I II DW POT FILLER 9'-4" C i I a� 0 60" A.F.F. N GREAT ROOM C— • 4�� I 10'-8" LG. CR WN I IT 4 MICRO WALL 5080 BP 268D OVEN} -S-10° CLG. N c ow9'- '-0 31-6- - 12'-0• a ■ T O .n • L� �' ■ WD ° O 0 °� 3 I 1 w �' 3 ,o — 2680 R F -� FROSTED a BEDROOM 2 Q O"c ¢ 16 uN S _ 9' CROWN r N MASTER �' r °° ® FLAT HD ■ O - ■ TEMP FRM GL TO FUR BATH -0 5'-6`' 'o ¢ ■ TOP OF G 0 84" A.F.F. 9'-4" CLG .m Z, n FROWN N 7'-6- 7' ® w — 5-2" 1 1'-4" o �+ = N MO o ROMAN 6' 2880 L 6 4° -6` `V o "w ¢ O FLAT HDR. BACKING FOR 0 8'-8" BASE/UPPER CABINETS 9'- °CLG. • ■ TI TO CLG. r ®36"-96' A.F.F. 7-0' 2 SO P N E SO N HE I TIL. ® ?s� a ACTIVE O 6-6° 11-4' O 9' 4° CL$'. GLASS C ER 5"E m ¢ FOYER I=�� 4° F.F. g r 1DINING 01, VTRLINE 1 o GR WN I I ®y, CRO ID J 5 SH! 0 a i EE BACKING FOR AUPPER CABINETS 1� IM� o DEN 0 96" A.F.F. UL J w 1 GREW • � _ • • • - R-11 BA7T INSULATION REQUIREMENTS PEERARAGE CROWN i LITE 308 DR W/ '-6 _p• R302.6 ¢ SILL LI ARCHED c ■ FG ABV 2 OVERDO i ■ • ■ • ENTRY'' I �(2) s 26 E 20 MIN. sou0 c • •• • 14'-8" CLG. iv (ABV MAIN SLAB) • DOOR W/ RIVE D JAMB OVERSIZED WEATHERSTRIPPING 22'x54' PULL DN STAIR L W/SW LT. J Jim 2 SH26 i •• •• • ----- mm al m mm oo I a 00 m m • ,00 GARAGE FLOOR cd o EPDXY STAIN o I ■ O 7 m 0p = 18 ATTACH P.T. 2X8 0 2 CAR GARAGE 'r I ABV. GARAGE DOOR I PER MANUF. SPECS I SMOOTH COAT STUCCO FINISH o i o EXCEPT AT DRYWALL SEE DETAIL THIS PAGE FRAME -OUT I I z � ELEC. & CHASE ■ I 23'-0" ELEC. PANEL I HOSE BIBB o i A -------� CHA CHASE� A4 LV i • • i • ii • ■ i • �— ■ i F w a w o m � w w w�S e u Z O� w U w z N j w a Q d) ro O Q C a co "- cn L C O [C T g c 2 0 �cu inn a� + p c s 13 m E CCi ;T canC Lu Lu S E V v a p 'd j ++ O V7 = Cn 0 vi � � O Y ' m z n of cn W� N Er 0 co 0 i 0= (D T N I~ �J Z o J LL. O O w ,-IO O ® � j Z) O w _J 2: Ln 1/4" = 1'-O" U.N.O. o SH Zb I P FLOOR PLAN A2 A 4-4' T.O.. 2'-6' 2'-3' 2'-3• 2'-B' 9'-4" TO.B.S. XEL4 T.O.B.a TO.B.B. - 9'-4' 3'-11- 2'-6" 6'-0' 2'-8' 3'-11" T-2' 7' 3* 9-10 7'-3' 711 E: 13`-3' ll'-40 11`-1' 24'-4' PROJECT LOG VINYLconos .�Yir•' Orta(¢r7�y Sues Product Submittal Sheet mYl - Iar,c r.1In m hm `fir '+r „' T"' Y/ O���'` 1 '� f' A '1 ^� Y I 11 Y-v.L%1�.-u-.v.�".vY.. u..uvL.r v�. �u11 �� s TY. :. -G - .vJ-. m`Z ::`- rye{, a� /l' y o t .l t'I RN rr Yv..__ \F�_�_a- t Mid Wall (M Style) Control Joint csl�idc6 _ .E ILc 5[rr ..,.,, srid ass is, lq coqtr 61 na crac.s i�j CLXtericii Iirils,n I iiterscc f ' 41aeoe� 3 vz nV2 schdflangn,rar4p Flae e rs i' d) �' IWIlC trlJ [ C tl In rd—[ d Y Iq-ck. it c prpr rmlfin sh. ni mot—trsaaaan tar rni r r o 11 , it rM1 wl rt_, bni N.Mcort fr urrss vnci. Product Submittal Sleet y,l 11- 75454 fL, M 131 ..C1 FLAT CONCRETE TILE 901 FELT SELF-ADHESIVE UNDERLAYMENT OVER 301 FELT TIN TAGGED Soffit Vents (One Piece) TO EXT. GRADE PLYWD. SHEATHING Lo r ,n:li.is c r) ece Sr ", a h iehffor'..rig o I<_; -_ stuaCo &:-: rla� cr. �� m (SEE DIAPHRAGM SCHEDULE FOR TYPE It NAILING PATTERN) PRE-ENG. WOOD ROOF TRUSSES — 024" 0/C TYPICAL cseaaoo, sB a widn vnintt ppcprs a width,P r pd f&qns W/APPROVED GALV. TRUSS A=CONC. RAISED STUCCO DETAIL FOAM MOLDING Mimi 'AMINE INEENIMINEEN ■■INEINEMENININEINNINEINEEN 12 D.P.= +31.9 PSF /� D.P.= +32.2 PSF 6 O -34.9 PSF /, \ BLW O -35.1 PSF r- :.rc�t rcnr._cnnrn,n�.. ncpoao snex Vlr mminf-ngre mkr n<n.mccr&amp. pla.mr VcntC4, _rr.,.:ded m, —pi,u Soffit vnnr and ANCHORSEA. END INSULATION Nona, 5 �4 , torkcnaln PER ENERGY CALC. a��. au �n<op�anon, °bw,� nr», or,m and:nmoa aremC nr In,milapn SEE PLAN) ELEV. • RAT RUNS PER d TRUSS MANE. GALV. MTL DRIP 5 8" DRYWALL OR 1/2' "TOUGHROCK' (OR EQUAL) APPLIED TO ON IX2 P.T. ; UNDERSIDE OF TRUSSES 21 PAINTED TEXTURED FIRE STOP SPRUCE FASCIA 2'1 CONT. 8"1 MASONRY BOND BEAM CEMEN717WS FINISH ON METAL LATH TYP. O.H. W/ 115 CONT. TOP & 80T. -FILL W/ COD. W/ 3" CONTINUOUS KW7ING ON ALL SIDES CONT. METAL POUR STOP (TRUSS CO. 70 PROVIDE FLAT SOFFIT) 1/2' DRYWALL a=6'-0' EDGE ZONE IX2 P.T. FURRING 24' 0/C MEDIUM TEXTURE DECORATIVE EXTERIOR BLOCK ALL 70 BE CEMENTITOUS FINISH OVER 8" CONC. BLOCK FLAT CONCRETE TILE 4 I NOT TO EXCEED 5/8" THICKNESS 901 FELT SELF-ADHESIVE UNDERLAYMENT OVER 301 FELT TIN TAGGED TO EXT GRADE PLYWD. SHEATHING (SEE DIAPHRAGM SCHEDULE FOR TYPE NAILING PATTERN) PRE-ENG. WOOD ROOF TRUSSES 024" 0/C TYPICAL W/APPROVED GALV. TRUSS ANCHORS EA. END j� SEE PLAN/ ELI GALV. MIL. DRIP ON IX2 P.T. 2x8 PAINTED TEXTURED SPRUCE FASCIA 2'-0" GEMEN71TOZ FINISH ON METAL LATH TYP. O.H. W/ 3' CONTINUOUS VENTING ON ALL SIDES (TRUSS CO. TO PROVIDE FLAT SOFFI MEDIUM TEXTURE DECORATIVE EMENTITOUS FINISH OVER 8' CONIC BLOCK NOT TO EXCEED 5/8" THICKNESS R 4.1 Fl-FOIL BETWEEN ST UDS 12 6 A2 R-40 INSULATION PER ENERGY CALC. RAT RUNS PER TRUSS MAW.. o 5 8' DRYWALL OR 1/2" 'TOUGHROCK" APPLIED TO � 0 UNDERSIDE) OF TRUSSES FIRE STOP CONT. 8746' MASONRY BOND BEAM W/ 115 CONT. TOP & BOT. - FILL W/ CONIC. CONT. METAL POUR STOP 1iV DRYWALL IX2 P.T. FURRING 0 24" 0/C EXTERIOR BLOCK WALL TO BE MONO. CONIC FOOTING SEE FOUNDATION PLAN FOR N07ES & DETAAS '' •. a • • • I III—III—IIII—� � ' •• _ I II TYPICAL WALL SECTION SCALE J/4' = ENTRY SOFFIT DETAIL SCALE 3/4' = 1'0' I I D.P.= +31.5 PSF O-34.5 PSF EDGE ZONE I I I I I I I I D.P.= +31.9 PSF O-34.9 PSF D.P.= +29.7 PSF O-32.6 PSF N a 12 6 ■ �—� EDGE O !�FOAM MOLDING I� I MEDIUM TEXTURE DECORATIVE CEMENTITOUS FINISH m ON BLOCK WALLS, TYP. ELI I RAISED STUCCO DETAIL n'—nl F!N F7 nrR SY AR .-6 D.P.= +33.5 PSF STUCCO BASE O -36.9 PSF FRONT ELEVATION - MISSION a=6'-0 EDGE ZONE I I I I I I I I D.P.= +33.2 PSF 36.2 PSF -6-0 EGGE ZONE I I I I I I I I I I I El pie■ ����-I I I0I III I=I 17w i in WRI I01I In ICI Ill Ili I ICI ICI ICI F-11=m r�l r�l I�r r�r I.. !fir ram! r�r �■� D.P.= +34.8 PSF D.P.= +34.8 PSF D.P.= +34.8 PSF O-37.8 PSF O -37.8 PSF O -37.8 PSF O D.P.= +29.3 PSF -34.0 PSF LEFT ELEVATION - MISSION ISSUED FOR START 10-02-19 ISSUED FOR PERMIT 11-01-19 BLDR. REV. 01-30-20 2 BLDG COMMENTS 03-11-20 3 TRUSS CONNECTOR REVISION 09-10-20 4 BUYER CHANGES REVS 09-21-20 Lq o- J �m� # _ $ R CP W W W d D LL W � W .W. W U m LL � Z. V J 0 a of v O w n �n — g O QUO_ pyj nc v d c L O co O cn 3 C7 v N r cf c a n ca `o m E � En 8 2 IS Lu 2E :E,�C� �i, E Cr O L = o E c`� O rn a o YYpp �E IUD a� N - - 0'-0" FIN. FLOE SLAB " ( ,) C O t Ar/ 0 r 14'-8" T.O.B.B, 11'-4" T.O.B.B. W-4" T.O.B.B. 0'-0" FIN. FL SLA - - %:- 1 >f f` ti o LL F/� 0 a 0 U O W Ti ?3 '—' ® � J W 1/4" = 1'1 U.N.O. ELEVATIONS A-3 fr1i-i MW - 01 ELECTRICAL SYMBOLS Q� DUPLEX RECEPTACLE $ SWTCH n TELEVISION JACK a DETEC TOR I AT 12' A.F.F. 1 SINGLE POE T PRE WIRED Q� DUPLEX RECEPTACLE $ SNITCxi 220 V. RECEPTACLE FLOOD SECURTY LIGHTS LIB AT BASE Ts THREE WAY AT 12" A.F.F. ® SMOKE QC DUPLEX RECEPTACLE SWITCH HVAC DETECTOR la AT 8" ABl! COUNTER �4 FOUR WAY ® THERMOSTAT SMOKE / CARBON MONOXIDE DETECTOR INTERCOM � DUPLEX RECEPTACLE SWITCH AT 60' A.F.F. SITCH FLUSH IN FLOOR �R RHEOSTAT � DISCONNECT TELEPHONE OUTLET DUPLEX RECEPTACLE SWITCH ® AT 12" A.F.F. PADDLE FAN GROUND FAULT �D DIMMER TELEPHONE OUTLET W/ /LIGHT FLUSH IN FLOOR FLUORESCENT DUPLEX RECEPTACLE SWITCH SPEAKER I FIXTURE CLG. MNTED. TOP REC. SWITCHED K KEYED IN aG, INCANDESCENT LIGHT DUPLEX RECEPTACLE SECURITY SPEAKER FIXTURE CEILING UNITED. WATERPROOF I KEYPAD WALL OUTLET INCANDESCENT LIGHT DUPLEX RECEPTACLE JUNCTION SPEAKER FIXTURE WALL. MATED. !PC UNDER COUNTER BOX 4 HOME RUN ® HI HAT CLG MOUNTED O INTERCOM p DOOR CA75 ® M HAT STATION I CHIME HOME RUN VAPOR PROOF ELEC. PANEL "A" 200 AMP CIRC. DESCRIPTION POLE BRKR WIRE VA. 100% 2 AHU HEAT STRIP 2 60 6 0 9.6 2 A/C COMPRESSOR 2 40 8 0 0 2 ELECTRIC COOKTOP 2 50 6 10.0 0 2 DBL WALL OVEN 2 50 6 10'0 0 2 DRYER 2 30 10 5.0 0 2 WATER HEATER 2 30 10 4.5 0 1 LAUNDRY 1 20 12 1.5 0 1 MICROWAVE 1 20 12 1.5 0 1 DISHWASHER/DISPOSAL 1 20 12 1.2 0 1 REFRIGERATOR 1 20 12 1.2 0 3 SMALL APPLIANCE 1 20 12 4.5 0 1 BATH GFI 1 1 20 12 1.5 0 14 GEN. LIGHTING 1 15 14 7.3 0 let 10,000 at 100% = 10.00 REMAINDER AT 40% = 15.28 A/C LOAD AT 657. = 6.24 TOTAL = 31.52 x 1000/240 = 131.3 AMPS ALL VANITY LIGHTS TO BE 100" A.F.F NOTE: ALL EDGE OF SWITCH PLATES TO BE NO LESS THAN 4" FROM OPENINGS NOTE: GARAGE PUSH BUTTON LOCATED 0 60' ABV GARAGE FLOOR 72' MAX. ® RECESSED EYEBALL USE! STA WIN F.P.&L. METER g & DISC. ® BREAKER PANEL EXHAUST FAN F L EXHAUST FAN W/ LIGHT R LV DOOR RELEASE (v� VOLUME CONTROL QUADRUPLEX RECEPTACLE ® LOW VOLTAGE TRANSFORMER FB FAN BOX IN CLG. NOTE: ACCEPTABLE SMOKE & CARBON DETECTORS TO BE INSTALLED ARE BRK SMOKE-9120B C/O—SC9120B KIDDE SMOKE-21007581 C/O 21006377—N NOTE: PROVIDE ARC —FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL RECEPTACLE AND LIGHTING OUTLETS INCLUDING SMOKE DETECTORS PER 2D17 NEC 210-12 (B). Plans are Prepared for the Builder and not any Planned or Future user / Home owner of the Subject Property and any Modifications, Deletions and other Changes Authorized by GHO Homes Corporation or other GHO entity are Permissible to included, but not be limited to Electrical Design Modification, Fixture or Outlet or Circuit changed, Combinations or Changes. All Final Work shall be at a minimum Equal to Code minimums and any changes are only Permissible if Suggested and complete by a licensed Electrician so long as Applicable Codes are Met and Load Sufficient to Meet GHO's minimum Level of Service and Operation. — (1) SETS OF (3) 14/0 AM.. THWN IN 2 CONDUIT 200 AMP SERVICE p METER DISC COMBO "A� O PANEL 200 A 5/8" COOK 10' CU SUPPLEMENTAL GROUND ROD AND 1D ONE REINFORCEING BAR IN 7HE FOUNDATION 20'-0' LONG MIN. ELECTRICAL RISER DIAGRAM CALCULATION NOTES: A. HEAT STRIP LOAD GOVERNS OVER CONDENSER UNIT LOAD. B. GENERAL LIGHTING CALCULATED 0 2503 (SQ.FT.) x 3 (WATTS/SQ.FT.) = 7509 / 14 (GEN.LTG.CIR.) = 536.4 (WATTS/EA.) C. A/C CONTRACTOR SHALL SIZE A/C UNITS. A/C UNITS SHOWN ARE FOR ELEC. CALCS. ONLY. *NOTE* — ALL ABOVE COUNTER AND ISLAND OUTLETS TO BE DECORA — ALL SWITCHES TO BE DECORA PROJECT LOG ISSUED FOR START 10.02.19 ISSUED FOR PERMIT 11-01-19 BLDR. REV. 01-30-20 BLDG COMMENTS 03-11-20 TRUSS CONNECTOR REVISION 09-10-20 BUYER CHANGES REVS 09-21-20 W a g � W J m ui d W w O f w W Z 3 yyy J LL Z z °o J a T Z a rt C ) o E Lo O t in 0 =0 C _ Q =_ O T U r N CV n h J LL z 0 O O W U G1 C5 O � � J r OJ W 2: Ln ELECTRICAL PLAN E-1