HomeMy WebLinkAboutUL EValuation ReportUL Evaluation Report
UL ER21-01
Issued: February 20, 2019
Revised: October 2, 2019
Vislt UL's Product ID'"' database for current status of Report.
UL Category Code: ULEZ
CSI MasterFormat®
DIVISION: 07 00 00 —THERMAL AND MOISTURE PROTEC
Sub -level 2: 07 30 00 — Steep Slope Roofing
Sub -level 3: 07 31 00 — Shingles and Shakes
Sub -level 4: 07 31 13 — Asphalt Shingle
COMPANY:
GAF
1 Campus Drive
Parsippany, NJ 07054
(800) 7663411
TechnicalQuestions@gaf.com
www,GAF.com
1. SUBJECT: Asphalt Shingles
Timberline® HDZTM, Timberline@ AH, Timberline@ CS
2. SCOPE OF EVALUATION
■ 2018, 20153 2012, 2009, and 2006 International Building Code @ (IBC)
■ 2018; 2015, 20123 2009, and 2006 International Residential Code @ (IRC)
■ ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated January 2019
The products were evaluated for the following properties:
■ Exterior Fire Exposure (ANSI/UL790, ASTM E108)
■ Wind Resistance (ASTM D3161; ASTM D7158)
■ Physical Properties (ASTM D3462)
Underwriters Laboratories Inc.
333 Pfingsten Road, North brook, IL 60062-2096 USA
T: 847.272.8800 / F: 847272.8129 / W: ULcom
3. REFERENCED DOCUMENTS
■ ANSI/UL790 (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings, Eighth Edition,
with revisions through October 19, 2018
■ ASTM 1)3161-16a, Standard Test Method for Wind -Resistance of Asphalt Shingles (Fan -Induced
Method)
■ ASTM D7158-17, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift
Resistance
■ ASTM D3462A6, Standard Specification for Asphalt Shingles Made from Glass Felt and Surfaced
with Mineral Granules
■ ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated January 2019
4. USES
GAF asphalt shingles are used as roof coverings for new and existing roofs.
5. PRODUCT DESCRIPTION
GAF asphalt shingles are roof covering materials complying with the following properties when installed
as described in this report. The products are laminated shingles and are available in metric sizes.
Fire Classification: GAF asphalt shingles covered under this Report have been tested for fire
classification Class A in accordance with UL 790 (ASTM E108). Shingles tested in accordance with
UL790 (ASTM E108) qualify for use under Section 1505.1 of the 20182 2015, 2012, 2009 and 2006 IBC
and Section R902.1 of the 2018, 20152 2012, 2009 and 2006 IRC,
Wind Resistance: GAF asphalt shingles covered under this Report have been tested for wind resistance
n accordance with ASTM D3161 and ASTM D7158.
Shingles tested in accordance with ASTM D3161 are classified as Class F and qualify for use under
Section 1504.1.1 of 2018, 2015 IBC, Section 1507.2.7.1 of the 2012, 2009 and Section 1504.1.1 of 2006
IBC, or the exception to Section R905.2.4.1 of the 2018, 2015, 2012, 2009 and 2006 IRC.
Shingles tested in accordance with ASTM D7158 are classified as Class H and qualify for use under
Section 1504.1.1 of 2018, 2015 IBC in locations as shown in Table 1504.1 1, Section 1507.2.7.1 of the
2012 and 2009 IBC in locations as shown in Table 1507.2.7.1 (1) or under Section R905.2.4.1 of the
2018, 2015, 2012 and 2009 IRC in locations as shown in Table R905.2.4.1, where the maximum basic
wind speed is 150 mph (67 m/s) or less with exposure category of B or C (ASCE 7) and a maximum
building height of 60 feet (18.3 m). Installation must be in accordance with Section 1507.2.6 of the 2018
IBC, Section 1507.2.7 of the 2015, 2012, 2009 and 2006 IBC or Section R905.2.6 of the 2018, 2015,
20122 2009 and 2006 IRC, as applicable.
Physical Properties: GAF asphalt shingles covered under this Report have been tested for physical
properties in accordance with ASTM D3462. Shingles tested in accordance with ASTM D3462 qualify for
use under Section 1507.2.4 of the 2018 IBC, Section 1507.2.5 of 2015, 2012, 2009 and 2006 IBC or
Section R905.2.4 of the 2018, 2015, 2012, 2009 and 2006 IRC. When installed on new construction in
accordance with this report and the GAF installation instructions, the shingles are a Class A roof covering.
When the shingles are installed over existing roof coverings, the Class A fire classification is maintained.
Page 2 of 10