Loading...
HomeMy WebLinkAboutGreen Solutions Stewart.J PHOTOVOLTAIC ROOF MOUNT SYSTEM 29 MODULES-ROOF MOUNTED - 9.860 kW DC, 8.410 kW AC, 2395 S ROCK ROAD, FORT PIERCE, FL 34945 PHOTOVOLTAIC SYSTEM SPECIFICATIONS: N SHEET INDEX: SYSTEM SIZE: 9.860 kW DC A-00: COVER SHEET 8.410 kW AC A-01: SITE PLAN MODULE TYPE&AMOUNT: (29)Q.PEAK DUO BLK-G6+/AC 340 w- e£E S 01: ATTACHMENT DETAIL MODULE DIMENSIONS: (L/W/H)68.5"/40.6"/1.57" E-01: ELECTRICAL LINE DIAGRAM INVERTER: (29)ENPHASE IQ7PLUS-72-2-US [240V] E-02: ELECTRICAL NOTES REVISIONS INTERCONNECTION METHOD: SUPPLY TAP N,u�� mt„ E-03: WARNING LABELS DS-01+ DATA SHEET DESCRIPTION DATE REV GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES a. 2017 NATIONAL ELECTRICAL CODE ROOF ACCESS POINT b. 2020 FL BUILDING CODE-7TH EDITION ROOF ACCESS POINT(S)SHALL BE LOCATED IN AREAS C. 2020 FL BUILDING CODE-7TH EDITION RESIDENTIAL THAT DO NOT REQUIRE THE PLACEMENT OF GROUND PROJECT NAME d. FLORIDA FIRE PREVENTION CODE LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS e. ANY OTHER LOCAL AMENDMENTS AND ARE LOCATED AT STRONG LOCATIONS OF BUILDING ' 11 FENCE CONSTRUCTION THAT DO NOT CONFLICT WITH GENERAL NOTES: OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. 1. APPLICABLE CODE: 2020 FLORIDA 391 -0 i'.� PROPERTY LINE BUILDING CODE(7TH EDITION)&ASCE 7-16 — — — — — — — — — Z j::i rn MINIMUM DESIGN LOADS FOR BUILDING " Q m AND OTHER STRUCTURES. 2. LAG SCREW DIAMETER AND EMBEDMENT 2 W �� LENGTHS ARE DESIGNED PER 2020 � STRUCTURE � � � U U FLORIDA BUILDING CODE (7TH EDITION) �cs\ � i Q w_ REQUIREMENTS. ALL BOLT CAPACITIES o MOLMU: � �� H ARE BASED ON A SOUTHER YELLOW PINE do ---__----------- 0 to (SYP) RESIDENTIAL WOOD ROOF RAFTERS i DRIVEWAY M AS EMBEDMENT MATERIAL. -- -------- ______ --- o Y �" LU cu O 3. ALL WIND DESIGN CRITERIA AND ___ U `'- "` H U_ PARAMETERS ARE FOR HIP AND GABLE ,�� -- - J 0 ;., _ Cn RESIDENTIAL ROOFS, CONSIDERING FROM LU o - A 7° TO A MAXIMUM 23° (5/12 TO A Cr- MAIN MAXIMUM 7/12 PITCH) ROOF IN SCHEDULE. ` MA.""°aSE I 2 SATELLITE VIEW LO CONTRACTOR TO FIELD VERIFY THAT 82 6 _ MEAN ROOF HEIGHT DOES NOT EXCEED U) o M A 00 SCALE:NTS SHEET NAME 30'-0". o; C-4 1. ROOF SEALANTS SHALL CONFORM TO 138'-0" coo COVER ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO ` ROOF#1 w R w, SHEET PILOT DRILL AND FILL ALL HOLES. (13)Q.PEAK DUO BLK-G6+/AC 340 I z SLOPE:23' - } US Agricultural ALL DISSIMILAR MATERIALS SHALL BE �? Department SHEET SIZE SEPARATED WITH NEOPRENE WASHERS, AZIM.:178° Sunshine Kitchen ANSI B M W T Farm to Fork d Agriculturat ��!rn T Fresh Market PADS, ETC OR SIMILAR. — — — — — O Research 8 Educ� 11" X 17" - - y and Harlot ALL ALUMINIUM COMPONENTS SHALL BE a �Green.Main�inance... ""1ePO ANODIZED ALUMINIUM 6105-T5 UNLESS t „ PROPERTY LINE Coastal SHEET NUMBER OTHERWISE NOTED. 267-O Embroidery&Hat II ROOF ACCESS POINT � � n ALL LAG SCREW SHALL BE ASTM A276 EXISTING EXTERIOR MAIN ^ds, •Pierce,FL34945,USA 2395 S Rock Rd,Fort ~-00 STAINLESS STEEL UNLESS OTHERWISE SERVICE PANEL TIED TO �. (12)Q. NOTED. EXTERIOR UTILITY METER ALL SOLAR RAILING AND MODULES SHALL Noonru PEAK DUO BLK-G6+/AC 340 `�J�j?y CEA g'F;CF9%' ROOF#2 SLOPE:23° '*�` N.""° BE INSTALLED PER MANUFACTURER I INSTRUCTIONS. (04)Q.PEAK DUO BLK-G6+/AC 340 AZIM.:88° =9. STATE OF ;'W= CONTRACTOR SHALL ENSURE ALL ROOF SLOPE:23° IALaO %°�FS�<oR;o*6.?,"• 3 VICINITY MAP b'sr ., PENETRATIONS TO BE INSTALLED AND AZIM.:268° <z� SEALED PER 2020 FLORIDA BUILDING A-oo SCALE:NTS CODE (7TH EDITION) OR LOCAL Digitally signed by John L Alger GOVERNING CODE. THIS DIGITAL PDF PLAN SET WAS ELECTRONICALLY SIGNED AND SEALED DN:c=US,o=Unaffiliated, 1 PLOT PLAN BY JOHN ALGER, P.E.ON THE DATE SHOWN USING IDENTRUST. THIS ou=AO1427D00000166EF1A9D COVER PAGE SEALS ALL SUBSEQUENT PAGES OF THIS PLAN SET. PRINTED COPIES ARE NOT CONSIDERED SIGNED AND SEALED AND ALL 100009E68,cn=John L Alger A-00 SCALE:3/128"=1'0" SHA-1 AUTHENTICATION CODE MUST BE VERIFIED. Date:2021.04.28 1 0:09:28-04'00' CONTRACTOR IS PERMITTED TO SHIFT N ROOF SECTIONS SYSTEM LEGEND AND/OR RELOCATE MODULES TO CLEAR R OOF MODULE 13 EXISTING EXTERIOR MAIN SERVICE PANEL&POINT OF ROOF TOP OBSTRUCTIONS AND FOR ° INTERCONNECTION.TIED TO EXTERIOR UTILITY METER. IMPROVED PERFORMANCE. FIELD E #01 AZIMUTH 178° Fr-1 NEW DEDICATED PV SYSTEM BREAKER PANEL. VERIFICATION OF ACTUAL DIMENSIONS IS MATERIAL COMP SHINGLE Fjg I NEW SOLADECK JUNCTION BOX. REQUIRED, ��„�„ ;,,,,e��� RAFTER SIZE 2"X4"@ 24"O.C. — NEW PHOTOVOLTAIC UTILITY DISCONNECT �7 ROOF MODULE 04 FACI SWITCH.LOCATED WITHIN 10'OF MSP. #02 SLOPE 23° 29 NEW Q.PEAK DUO BLK-G6+/AC 340 MODULES WITH AZIMUTH 268° NEW 29-ENPHASE IQ7PLUS-72-2-US [240V] MATERIAL COMP SHINGLE MICROINVERTERS,MOUNTED ON THE BACK OF EACH MODULES. REVISIONS RAFTER SIZE - 2"X4"@ 24"O.C. E]0 =ROOF OBSTRUCTIONS DESCRIPTION DATE REV -------------- ROOF MODULE 12 • =ATTACHMENT POINTS #03 SLOPE 23° =RAFTER AZIMUTH 88° =RACKING SYSTEM ------------ MATERIAL COMP SHINGLE RAFTER SIZE - 2"X4"@ 24"O.C. =CONDUIT EXTERIOR RUN --- =CONDUIT ATTIC RUN PROJECT NAME CIRCUIT(S) _ =FIRE PATHWAY --- - - CIRCUIT#1 - 13 MODULES =WIND ZONE 1 Ilw =WIND ZONE 2e,2n AND 2r U U-) CIRCUIT#2- 12 MODULES Z -— =WIND ZONE 3r AND 3e W p - CIRCUIT#3-4 MODULES MODULE, ARRAY WEIGHT co oOf i (LOAD CALC'S) w L 4 1 24'-2" __ 8 11 q�FAyTy Q Number of Modules 29 0 U ��q� Module Weight 47.2 LBS W_ q w Total Module(Array)Weight 1368.80 LBS — o Number of Attachment point 73 M F- P LL 0 Mounting System Weight 1.5 LBS W c1 ZONE 2r IS A 4 FT. 0 Q (PerMod"te) li ���� ZONE FROM RIDGE z Mounting System Weight 109.50 LBS 0 DOWN w Total System Weight L (Module Weight+Mounting SystemWeighrt) 1478.30 LBS �M � ZONE 1 � Weight at Each Attachment Point M 18.75 LBS M ch ^1 (Array Weight/Number ofAttaohment Point) V Module Area(68.5"x40.6") 19.31 SgFt SHEET NAME Elo Total ArrayArea 560.08 S Ft 3'-0" 16'-10"—� 4'0" — Y o q a i Distributed Load RooF#01 Cn ZONE 2e IS A 4 FT MODULE RATING IS-75.0 PSF SO IT MAY BE INSTALLED (Total System Weight/TotalAr ay Area) 2.52 Per SgFt SITE PLAN WIDE ZONE ALONG IN ALL ROOF ZONES. Total Roof Area 3034 SgFt M a' THE EAVE M 46/0 GENERAL INSTALLATION PLAN NOTES: Total Percentage or Roof Covered 18. o o SHEET SIZE 4 FT SQUARE CORNERS C JIB ROOF ATTACHMENTS TO SEE RAFTERS SHALL BE TntalArayArea/T°talR°ofAeartgo ANSI B AC ARE ZONE 3e INSTALLED AS SHOWN IN SHEET S-01 AND AS DESIGN CRITERIA 11" x 17" FOLLOWS FOR EACH WIND ZONE: ROOF LIVE LOAD(psf) 20 b GROUND SNOW LOAD(psf) SHEET NUMBER M s"PR WIND ZONE 1,2e: 4-0 O.C. O a°F E ' "v Zh WIND SPEED(mph) 157 A_O 1 IF 64" 5'-8" 6" WIND ZONE 2n,2r AND 3e : 4'-0"O.C. EXPOSURE CATEGORY B 3'-0" 2)PERIMETER WIDTH IS 4 FT IN ALL CASES AS PER THE ROOF HEIGHT(ft.) 30 SIGNATURE WITH SEAL ROOF LENGTH(ft.) 66 2020 FBC 7TH ED ZONE 2n IS A 4 FT WIDE ZONE FROM IROOF WIDTH(ft.) 60 THE SIDE PRESSURES WERE INTERPOLATED FROM THE PARAPET HEIGHT(ft.) 0 ZONE 3r IS A 4 FT COMPONENTS AND CLADDING TABLE ON PAGE 25 FOR DESIGN CALCULATION SQUARE CORNERS GABLE ROOFS IN THE 2020 FBC 7TH ED RESIDENTIAL FOR WIDTH OF PRESSURE COEFFICIENT AT RIDGE RISK II EXPOSURE B ENCLOSED STRUCTURES. ROOF LENGTH x 10%(ft.) 6.6 THIS PAGE IS PART OF A DIGITALLY AN ADJUSTMENT FACTOR OF 1.21 WAS USED TO ROOF HEIGHT x 40%(ft.) 12.0 SEALED PDF PLAN SET THAT WAS CONVERT FROM EXPOSURE B AT 30 FT TO EXPOSURE C ZONE WIDTH"A" 4.0' ELECTRONICALLY SIGNED AND SEALED AT 13 FT. SITE IS EXPOSURE C BY JOHN ALGER, P.E. ON THE COVER 1 SITE PLAN WIND SPEED USED WAS 157MPH FROM ATC,ROOF PITCH WIND ZONE 1 AND 2e -45.900 PAGE. PRINTED COPIES ARE NOT A-01 SCALE:3/32"-V-0" WAS 23 DEGREES AND THE AFFECTED AREA IS 18 SQ FT. WIND ZONE 2r,2n AND 3e -66.100 CONSIDERED SIGNED AND SEALED. WIND ZONE 3r -75.900 130 1 120 15 PV MODULE 1 0 115 130 15 120 SEE (2/S-01) FOR Sa° olmes Rosa ENLARGED VIEW Jackson o Walton w. ngten Gadsden N sau Hamilton Ba Calhoun Leon Madison 1O E Duval G Liberty Wakulla Suwannee Baker Franklin nion adford Clay St. 140 REVISIONS 2y 150 Alachua John DESCRIPTION DATE REV D Putnam Dixie Fla er Levy 150 Marion ee$ Volusia (E) COMP SHINGLE ROOF 140 citrua Seminole PROJECT NAME € Lake Hemando Orange Pasco 160 150 — 0sce a 8re rd W _ Hi orough Polk U 117 than 170 Z verLU Q 1 Notes: Manatee eechobee t.ATTACHMENT DETAIL SIDE VIEW e O Highlands ude 1. Values are nominal design 3-second gust Cl) u- S-01 SCALE:NTS wind seeds in miles s ota Desoto LU p per hour (m/s) at 33 160 Ma " Y ft (10m) above ground for Exposure C cat— harlotte Glades U LJ.I IRONRIDGE INTEGRATED GROUNDING egory. � O U & END/MID CLAMP O Hendry BPatin eac � (Ifw 2. Linear interpolation between contours 170 lee PV MODULES is permitted. u) to 3. Islands and coastal areas outside the Browa j � last contour shall use the last wind speed collier W N O contour of the coastal area. 180 LJ_ IRONRIDGE XR-100 RAIL 4. Mountainous terrain, gorges, ocean 180 o Cl) promontories, and special wind regions Dade nroe shall be examined for unusual wind condi- QUICKMOUNT L-FEET tions. 5. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years �f (Annual Exceedance Probability = 0.00143, moo_ a d SHEETNAME MRI = 700 years). o 0 o MOUNT QUICKMOUNT FLASHING DETAIL 5/16" EPDM BONDED Figure 1609A Wind-Borne Debris Region, Category II and III SHEET SIZE 304-18.8 SS WASHER Buildings and Structures except health care facilities ANSI B 11" x 17" SHEET NUMBER 2"X4" RAFTER @ 24" OC S-0 SIGNATURE WITH SEAL 5/16"x3"SS LAG BOLT WITH MIN 2-1/2" THREAD EMBEDMENT, SEALED PENETRATION THIS PAGE IS PART OF A DIGITALLY SEALED PDF PLAN SET THAT WAS ELECTRONICALLY SIGNED AND SEALED 2 ATTACHMENT DETAIL ENLARGED VIEW BY JOHN ALGER, P.E. ON THE COVER PAGE. PRINTED COPIES ARE NOT s-o1 SCALE:NTS CONSIDERED SIGNED AND SEALED. WIRE WIRE TYPE WIRE WIRE TEMP WIRE I TEMP CONDUIT WIRE TERMINAL INVERTER STRING GRND GRND WIRE TAG# WIRE FROM -- CONDUIT QTY GAUGE: RATING: AMP DE-RATE: FILL: OCP: 75'C RATING: QTY: NOC: NEC: AMPS SIZE TYPE O1 ARRAY TO JUNCTION BOX TRUNK 6 #10 THWN-2 90, 40A x 0.96 x N/A = 38.40A 35A 13 x 1.21 x 1.25 = 19.66A #6 SBC CABLE O2 JUNCTION BOX TO COMBINER PANEL 3/4" EMT 6 #10 THWN-2 90, 40A x 0.76 x 0.80 = 24.32A 35A 13 x 1.21 x 1.25 = 19.66A #8 THWN-2 O3 COMBINER PANEL TO ACD 3/4" EMT 3 #8 THWN-2 75' 50A x 0.94 x 1.00 = 47.00A 50A 29 x 1.21 x 1.25 = 43.86A #8 THWN-2 ® ACID TO MAIN SERVICE PANEL 3/4" EMT 3 #6 THWN-2 75' 65A x 0.94 x 1.00 = 61.10A 65A 29 x 1.21 x 1.25 = 43.86A SYSTEM DATA REVISIONS Rooftop conductor ampacities designed in compliance DESCRIPTION DATE REV with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), TOTAL MODULES: 29 ENPHASE Q CABLE TO BE ATTACHED TO RAIL ( )( )( ) ) p TOTAL INVERTERS: 29 310.15 B 3 c , 310.15(B)(16 , Chapter 9 Table 4, 5, &9. MIN. 3-1/2"ABOVE ROOF SURFACE Location specific temperature obtained from ASHRAE SYSTEM RATINGS: 9.860kW DC STC 2017 data tables PROJECT NAME RECORD LOW TEMP 0°C AMBIENT TEMP(HIGH TEMP 2%) 33°C CONDUIT HEIGHT 0.5" W U L' ROOF TOP TEMP 55°C Z rn LLJ CONDUCTOR TEMPERATURE RATE ON ROOF 90°C c� O J CONDUCTOR TEMPERATURE RATE OFF ROOF 75T W LJ_ U uJ U POINT OF INTERCONNECT, SUPPLY SIDE TAP � w EXISTING 240V/200A BUS BAR RATING, cn a- MAIN SERVICE PANEL, SINGLE PHASE, M � WITH A 200A MAIN DISCONNECT W cal O Ill U_ N COMBINER PANEL ENPHASE IQ COMBINER X-IQ-AM1-240-3 64A/240V M CONTINUOUS, PROTECTION MAX 80A LINE SIDE TAP (N) LOCKABLE BLADE TYPE 4 MICRO-INVERTERS IN BRANCH CIRCUIT#3 BREAKER ON SOLAR OUPUT; WITH 10 FUSIBLE AC DISCONNECT SHEET NAME KAIC CIRCUIT BREAKERS 60A-2P 120/240VAC ' 3-LINE 11-M =ti - SOLADECK BOX OR UL 1741 40A FUSES 200A E--{ DIAGRAM 1 1 1 APPROVED EQUIVALENT TO ---- ------- - TRANSITION FROM Q-CABLE fOA (E)LOADSSHEET SIZE 12 MICRO-INVERTERS IN BRANCH CIRCUIT#2 TO THWN 2 WIRE NO FUSE ��REQUIREDANSI B 11" x 17" (E)LOADSL1 SHEET NUMBER , L, L, L2 E-01 r�FF- L2 L2 I 13 MICRO-INVERTERS IN BRANCH CIRCUIT#1 j L1 L1 M. Envo-S INN SIGNATURE WITH SEAL L2 L2 y G N - ---- - -- -- ------- - FG N G G - I 1 2 3 4 EXISTING GROUNDING THIS PAGE IS PART OF A DIGITALLY TERMINATOR CAP ON LAST CABLE SEALED PDF PLAN SET THAT WAS CONNECTOR AC TRUNK CABLE(TYP) ELECTRODE SYSTEM ELECTRONICALLY SIGNED AND SEALED BY JOHN ALGER, P.E. ON THE COVER PAGE. PRINTED COPIES ARE NOT CONSIDERED SIGNED AND SEALED. ELECTRICAL NOTES: SYSTEM NOTES: INVERTER SPECIFICATIONS 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND 1. ENPHASE IQ7 / 7PLUS MICROINVERTERS DO NOT REQUIRE LABELED FOR ITS APPLICATION. GROUNDING ELECTRODE CONDUCTORS OR EQUIPMENT MANUFACTURER ENPHASE ENERGY IQ7PLUS-72-2-US 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND GROUNDING CONDUCTORS. THE MICROINVERTERS ITSELF HAS MAX.DC VOLT RATING 60VOLTS 90 DEGREE C WET ENVIRONMENT. CLASS II DOUBLE-INSULATED RATING, WHICH INCLUDES GROUND MAX.POWER AT40 C 235 WATTS 3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS FAULT PROTECTION. SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE 2. ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLE NOMINAL AC VOLTAGE 290VOLTS AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. INSULATED CABLING) MAX.AC CURRENT 1.21 AMPS 4. WORKING CLEARANCES AROUND ALL NEW AND EXISTING 3. MODULES ARE BONDED TO RAIL USING UNIRAC INTEGRATED ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. GROUNDING. MAX.OCPD RATING 20 AMPS 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF 4. RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS MAX.PANELS/CIRCUIT 13 REVISIONS SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY 5. SYSTEM IS UNGROUNDED SHORT CIRCUIT CURRENT 15AMPS DESCRIPTION DATE REV OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO 6. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA FULFILL APPLICABLE CODES AND STANDARDS. IRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC PV MODULE RATING @ STC 6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND 250.64(C) CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL 7. SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTAL MANUFACTURER Q.PEAK DUO BLK-G6+/AC 340 SIZE THEM ACCORDINGLY. BRANCH CIRCUIT. MAX.POWER-POINT CURRENT(IMP) 10.02 AMPS PROJECT NAME 7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY 8. ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRAL LABELED AND READILY VISIBLE. TO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PER MAX.POWER-POINT VOLTAGE(VMP) 33.94 VOLTS 8. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN ENPHASE INSTALLATION INSTRUCTIONS. OPEN-CIRCUIT VOLTAGE(VOC) 40.66VOLTS MODULE FRAME AND MODULE SUPPORT RAIL, PER THE 9. ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READY SHORT-CIRCUIT CURRENT(ISC) 10.52AMPS W GROUNDING CLIP MANUFACTURER'S INSTRUCTION. PER NEC 690.12 NOM.MAX.POWER AT STC(PMAX) 340 WATT V Lo Lo 9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS Z rn COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN MAX.SYSTEM VOLTAGE 1000 VDC Lu Q co LU .10. UTIGLITY HAS 24-HR UNRESTRICTED ACCESS TO ALL VOC TEMPERATURE COEFFICIENT -0.27°%/°C (q of U_ PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE w U U SERVICE ENTRANCE. O � 11. WORKING CLEARANCES AROUND THE EXISTING AND NEW H u1 ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN U ACCORDANCE WITH NEC ARTICLE 110.26. LABLES Q rn H 12. ALL EQUIPMENT INSTALLED SHALL BE LISTED BY A W co 0 NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) PHOTOVOLTAIC DC PER INVERTER U- PER NEC ARTICLE 110.3. RATED MPP CURRENT 9.60 A 13. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 14. ALL LABELS OR MARKINGS SHALL BE VISIBLE AFTER SYSTEM DATA RATED MPP VOLTAGE 38.00 V INSTALLATION. THE LABELS SHALL BE REFLECTIVE, AND ALL #STRINGS: 03 MAX SYSTEM VOLTAGE 44.30 V LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM SMALLEST STRING: 04 HEIGHT OF 9.5 MM (3/8 IN) IN WHITE ON A RED BACKGROUND. LARGEST STRING: 13 SHORT CIRCUIT CURRENT 10.26 V SHEET NAME 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS TOTAL MODULES: 29 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND PHOTOVOLTIAC AC OUTPUT ELECTRICAL ARTICLE 310.8 (D). TOTAL INVERTERS: 29 AC OUTPUT CURRENT 35.09A NOTES 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SYSTEM RATINGS: 9.860kW DC STC SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE BATTERY RATING: N/A NOMINAL AC VOLTAGE 240V 310.8 (C). SHEET SIZE ANSI B 11" x 17" SHEET NUMBER E-02 SIGNATURE WITH SEAL I JOHN L ALGER, PE# CERTIFICATE OF 74730, AN ENGINEER AUTHORIZATION# PURSUANT TO CHAPTER 471 OF THE FLORIDA STATUTES, HERE BY STATE 31930 THAT I HAVE EVALUATED ALL OF THE COMPONENTS ENGINEER OF RECORD THIS PAGE IS PART OF A DIGITALLY AND THE SYSTEM AS A JOHN L. ALGER SEALED PDF PLAN SET THAT WAS WHOLE AND CERTIFY THAT ELECTRONICALLY SIGNED AND SEALED IT MEETS OR EXCEEDS PROFESSIONAL ENGINEER BY JOHN ALGER, P.E. ON THE COVER THE REQUIREMENTS OF: PAGE. PRINTED COPIES ARE NOT FL. LICENSE NO. 74730 CONSIDERED SIGNED AND SEALED. NOTES AND SPECIFICATIONS: ztWA R N I N G OWARN I N G SOLAR PV SYSTEM •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED EQUIPPED WITH RAPID BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING COMBINER PANEL SHUTDOWN EFFECTIVE WORDS,COLORS AND SYMBOLS. DO NOT TOUCH TERMINALS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR TERMINALS ON LINE AND LOAD DO NOT ADD LOADS TURN RAPID WIRING METHOD AND SHALL NOT BE HAND WRITTEN. SIDES MAY BE ENERGIZED IN LABEL LOCATION: SHUTDOWN •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE THE OPEN POSITION PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). SWITCH TO THE ENVIRONMENT INVOLVED. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT PER CODE(S):CEC 2016:705.12(D)(2)(3)(c),NEC "OFF" POSITION TO SOLAR SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. LABEL LOCATION: 2017:705.12(D)(2)(3)(c),NEC 2011:705.12(D)(4) SHUTDOWN PV ELECTRIC •DO NOT COVER EXISTING MANUFACTURER LABELS. INVERTER(S),AC DISCONNECT(S),AC SYSTEM AND PV PANELS REVISIONS COMBINER PANEL(IF APPLICABLE). REDUCE DESCRIPTION DATE REV PER CODE(S):CEC 2019:690.17(B), SHOCK HAZARD NEC 2017:690.17(E),NEC 2011:690.17(4) IN THE ARRAY OWA R N I N G OWA R N I N G PROJECT NAME DUAL POWER SUPPLY INVERTER OUTPUT CONNECTION SOURCES: UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE W C.� `0 SYSTEM LABEL LOCATION: Z rn ADJACENT TO PV BREAKER(IF APPLICABLE). W Q cM LABEL LOCATION: `Q 0 LJL_ UTILITY SERVICE METER AND MAIN SERVICE PER CODE(S)::CEC 2019:b),NE( 2 PANEL. NEC 2017:705.12(D)(2)(3)(b),NEC 2011:705.12(D)(7) U LU PER CODE(S):NEC 2017:705.12(D)(3), � of � NEC 2011:705.12(D)(4) W_ co co (If Q � WARNING: PHOTOVOLTAIC W "I O POWER SOURCE LL- LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):CEC 2019:690.13,NEC 2017:690.31(G)(3), SHEET NAME 690.31(G)(4),NEC 2011:690.31(E)(3),690.31(E)(4),IFC 2012: 605.11.1.4 WARNING LABELS .PHOTOVOLTAIC AC DISCONNECT SHEET SIZE MAXIMUM AC •- 09 AMPS ANSI B NOMINALOPERATING . 11" x 17" LABEL LOCATION: SHEET NUMBER AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF E-03 INTERCONNECTION. PER CODE(S):CEC 2019:690.53,NEC 2017:690.54,NEC 2011:690.54 SIGNATURE WITH SEAL THIS PAGE IS PART OF A DIGITALLY SEALED PDF PLAN SET THAT WAS ELECTRONICALLY SIGNED AND SEALED BY JOHN ALGER, P.E. ON THE COVER PAGE. PRINTED COPIES ARE NOT CONSIDERED SIGNED AND SEALED. powered by MECHANICAL SPECIFICATIONS �" ©U Format 68.5 x 40.6 x 1.571n(including frame) (1740 x 1030 x 40mm) Ev.v'I�Aa mml aave LRao mm] u.P•lava,,.,,! Weight 47.21bs(21.4kg) Front Cover 0.131n(3.2mm)thermally pre-stressed glass 1 L with antl-reflection technology A-ew.nens pom..°.vr lA.s mm} Rem. Back Cover Composite film 3aEz'R°mmt Frame Black anodized aluminum LLI ms Iv,ao m*r Cell 6 x 20 monocrysialline Q,ANTUM solar half cells Junction Box 2.09-3.98 x 1.26-2.36 x O.59-0.711n(53-ICI x 32-60 x 15-1Bmm), Protection class IP6Z with bypass diodes Cable 4mm2 Solar cable;(+)>_45.3in(1150mm),(-)a33.51n{850mm) s.P,eimm.no�, °.Mmmm,p de IDETAILAI -_ Connector Staubli MC4;IP68 PLTAILA a.ese rzas mmll�I-Is.-1 ■ . • ' AC OUTPUT ELECTRICAL CHARACTERISTICS IQ713LUS-724CM-US OR IQ7PLUS-72-E-ACM-US Peak Output Power [VA] 295 AC Short Circuit Fault Current over 3 Cycles 5.8 Arms All Max.Continuous Output Power [VA] 290 Max.Units per 20 A(L-L)Branch Circuit 13 Nominal(L-L)Vokage/Range IM 240/M-2B4 Overvoltage Class AC Port III • ` • • • A •• F5f Q Max.Continuous Output Current [A] 1.21 AC Port Backfeed Current 18 mA ' • ' • Nominal Frequency [H7] 60 Power Factor Setting 1 ' TOP B;ANO PV eusoPe Extended Frequency Range [Hz] 47-68 Power Factor(adjustable) 0.85 leading_...0.85 lagging ZRZR DC ELECTRICAL CHARACTERISTICS V$A Warranty Q CELLS P,od�c 8 Perlormsnce Yield Securlt POWER CLASS 340 345 340 34B MINIMUM PER FORMANCE AT STANDARD TEST CUPTIONS STC1(POWER TOLERANCE+5W/-OW) Min.Power at MPP' PMPP [w] 340 345 Min.Current at MPP IMPP [A] 10.02 10.07 Min.Short Circuit Current' Isc [A] 10.52 10.58 MIn.Voltage at MPP VMPP IV] 33.94 34.25 Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY Min-Open circuit Voltage' Voc M 40.66 40.92 Min.EffiCieney' n [%] >19.0 >19-3 Higher yield per surface area,lower BOS costs,higher 'Measurement tolerances p.Pa+3%;Ivc:V°ct,s%at STc:l000w/mr,25}2^C,AM 1,5 according to IEC 6t)904-3 power classes,and an efficiency rate of up to 19.596. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE INNOVATIVE ALL-WEATHER TECHNOLOGY -7 -°�' " -1i4itlir At least 98%of nominal power during x 1O --T_____r-----' ---- -----� _a5 i�a��rv� > Optimal yields,whatever the weather with excellent a 3 --- - first year.Therestter max,0,54% W i 1 ' vw degradation per year.At least 93.1% low-light and temperature behavior. 9 P v g p >4 °° of nominal power up to 10 years.At ,o -- m o least 85%of nominal power a to I I P P ENDURING HIGH PERFORMANCE az 25years. �° r. �-___-ii------------ Long-term -----� a ield securit with Anti LID Technology,Anti PID w y� y gy All data within measurement tolerant_ii ii I I o Technology',Hot-Spot Protect,Traceable Quality Tra.Q"`". a as.Full warranties in accordance with w uo ,00 wo No woo the warranty terms of the Q CELLS �I a n IR RA DrANCE tW/mg o sales argani7atien of your respective N EXTREME WEATHER RATING .° Mom,°w m YEARS country. N �nv� mrhrar^{m°'-se ��pr°! Typical module performance under low Irradiance conditions In 777/// High-tech aluminum alloy frame,certified for comparison toSTC conditions(25'c,1000wIm�) M high snow(5400 Pa)and wind loads(4000 Pa). TEMPERATURE COEFFICIENTS U �j A RELIABLE INVESTMENT Temperature Coefficient ofI,c a [%/K] +0.04 Temperature Coefficient of Vac a I%/K] -0.27 a' cc5SccJJ Inclusive 25-year product warranty and 25-year Temperature Coefficient of P_ y [%/K] -0.36 Nominal Module Operating Temperature NMOT [°F] 10915.4(43±3°C) YEARS m linear performance warranty'. o PROPERTIES FOR DC SYSTEM DESIGN STATE OF THE ART MODULE TECHNOLOGY Maximum System Voltage Vats [VI 1000 PV Module Classification Class II {- Q.ANTUM DUO Technology and the integrated high-powered Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 1703 TYPE 2 a Enphase IQ 7+Microinverter achieving maximum system efficiency. Max.Design Load,Push/Pull' [Ibs/ft2] 75(3600Pa)/55(2567Pa) Permitted Module Temperature -40°F up to+185°F U s on Continuous Duty (-40°C up to+85°C) o RELIABLE ENERGY MONITORING Max.Test Load,Push/Pull [Ibs/ft] 113(5400Pe)/84(4000Pa) Seamless management with the intelligent Enphase asee Installation Manual EnlightenTM'monitoring system. QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION - RAPID SHUTDOWN COMPLIANT Solarm.dul.:UL1703, Number of Modules per Pallet 26 = Built-in rapid shutdown with no additional components required. U.S.Paten[Na 9,893,216(saler-11s);Enphu.mlaroImr.M.raL 17A1SA.UL92109-1. Number of Pallets per Trailer(za t) 2B uu7411IEEE1s47,FCC Pan15C1...3, q Number of Pellets per 40'HC-Container(26 t) 26 'APT test conditions according to I EC/TS 62804-1:2015.method B(-1500 V,158h) ICES-0003 Class a,CAN/GSA-C22.2 NO.10 A-OL - us Pallet Dimensions L x W x H 70.1 x 42.5 x 47.61n(1780 x 1080 x 1208 mm THE IDEAL SOLUTION FOR: 9.PldshudowPcamPn.mP.rNEc-sofa ( ) ) 'See data sheet an rear for further information �, _ &2017&G2212o15 Pallet Weight 13101bs(594 kg) - Rooftop arrays on a residential buildings Note:Installation Instructions must be followed.Seethe Installailon and operating manual or contact our technical service department for further Information on approved Installation and use of this product OCELLS 4hanwha 00 Spectrum CELLS America Inc. Engineered in Germany 400 Spectt rum Center Riive.Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters Region: AMERICAS INPUT DATA(DC) IQ7-60-2-us IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell/120 half-cell PV modules 60-cell/120 half-cell and 72- only cell/144 half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Enphase The high-powered smart grid-ready Max DC short circuit current(module Ise) 15 A 15 A Enphase IQ 7 Micro TM and Enphase IQ 7+ MicroT" Overvoltage class DC port Il n DC port backfeed current 0 A 0 A Q7 and IQ 7+ dramatically simplify the installation process while PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit Microinverters achieving the highest system I efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Part of the Enphase IQ System,the IQ 7 and Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA IQ 7+ Microinverters integrate with the Enphase Nominal(L-L)voltage/range 2 240V/ 208V/ 240V/ 208V/ IQ Envoys", Enphase IQ Battery'", and the Enphase 211-264V 183-229V 211-264V 183-229V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten" monitoring and analysis software. Nominal frequency 60 Hz 60 Hz IQ Series Microinverters extend the reliability Extended frequency range 47-68Hz 47-68Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) undergo over a million hours of power-on testing, Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 Warranty of up to 25 years. Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97-6% 97.5% 97.3% CFC weighted efficiency 97.0°i 97.0% 97.0% 97.0°i MECHANICAL DATA Ambient temperature range -400C to+65°C Easy to Install Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) • Lightweight and simple Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Faster installation with improved,lighter two-wire cabling Weight 1.08 kg(2.38 Ibs) • Built-in rapid shutdown compliant(NEC 2014&2017) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure • Optimized for high powered 60-cell/120 half-cell and 72- Environmental category/UV exposure rating NEMA Type 6/outdoor cell/144 half-cell*modules FEATURES j More than a million hours of testing Communication Power Line Communication(PLC) • Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. 4 UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Smart Grid Read Compliance CA Rule 21 (UL 1741-SA) y UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 • Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC frequency ride-through requirements 2017,and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, Remotely updates to respond to changing for AC and DC conductors,when installed according manufacturer's instructions, grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 1,No enforced DC/AC ratio.Seethe compatibility calculator at hltps7lienphase.com/en-us/support/module-compatibility. *The IQ 7+Micro is required to support 72-cell/144 half-cell modules. 2.Nominal voltage range can be extended beyond nominal if required by the utility. r 3,Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. EN PHASE, To learn more about Enphase offerings,visit enphase.com n E N P H AS E To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy All rights reserved.Enphase,the Enphase logo,Enphase 14 7,Enphase IQ 7+,Enphase IQ Battery, Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-08-12 Data Sheet Enphase IQ Combiner 3 Enphase Networking MODEL NUMBER IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy-printed circuit board for integrated revenue grade PV X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect- CELLMQDEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 6❑ CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). Enphase The Enphase IQ Combiner 3— with Enphase CT-200-SPLIT Consumption monitoring is required for Enph ass Storage systems IQ Envoy'"' consolidates interconnection Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encharge-storage and Enphase Q Combiner 3 COMMS-KIT-01 Enpower"smart switch.Includes USB cableforconnection to IQ Envoy or Enphase IQ Combiner- equipment into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK10A-2-240 Circuit breaker,2 pole,I OA,Eaton BR21 0 BRK 15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 providing a consistent, pre-wired solution for BRK-20A-2P-240 Circuit breaker,2 pole.20A,Eaton BR220 EPLC-D1 Power line carrier(communication bridge pair),quantity-one pair residential applications. It offers Lip to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-D1) 2-pole input &cuits and Eaton BR series XA-ENVPCBA3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS �rusbar assembly. Rating Continuous duty System voltage 12D/240 VAC,60 Hz Fawn BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 9D A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Smart Max.continunus.current rating(input from PV) 64 A • Includes IQ Envoy for communication Max.total branch circuit breaker rating(input) 80A of distributed generation/9DA with IQ Envoy breaker included and control Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy Flexible networking supports Wi-Fi, MECHANICAL DATA Ethernet,or cellular Dimensions(WxHxD) 49.5 x 37.5 X 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). 1 • Optional AC receptacle available for PLC Weight 7.5 kg(16.5 Ibs) r bridge Ambient temperature range -400 C to+460 C(-400 to 1150 F) - Provides production metering and optional consumption monitoring Cooling Natural Convection,plus heat shield Enclosure environmental rating Outdoor.NRTL certified,NEMA type 3R,polycarbonate construction I�I u r Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors Simple 60 A breaker branch input: 4to 1/DAWG copper conductors 4 Main lug combined output: 10 to 2/DAWG copperconductors [ Reduced size from previous combiner Neutral and ground: 14 to 1/0 copper conductors 1 Always follow local code requirementsfor conductor sizing. • Centered mounting brackets support single Altitude To 20DD meters(6,560 feet) stud mounting INTERN ET CONNECTION OPTIONS • Supports back and side conduit entry Integrated Wi-Fi 802.11 hlgln • Up to four 2-pole branch circuits for 240 VAC plug-in breakers(not included) Ethernet optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) • 80 A total PV or storage branch circuits Cellular Optional,GELLMODEM-01 (3G)or CELLMODEM-03(4G)or CELLMODEM-Mt (413 based LTE-M) (not included) COMPLIANCE Reliable Compliance,Combiner UL 1741, CANICSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure V` Five-year limited warranty UL lisled To learn more about Enphase offerings,visit enphase.com LISTED 0 2018 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the To learn more about Enphase offerings,visit enphase.com *:' E N P H A S E tm a a rkss of Enphase Energy,Inc. � E N P H AS E /A� IRON RIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, i but the worst storms in 40 years. High winds capable of i ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect XR10 XR100 xR1000 against buckling and safely and efficiently 1 xR10 is a sleek, low-profile mounting XR 100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the building structure. rail,designed for regions with lightor mounting rail.It supports a range of solar mounting rails. It's built to handle Their superior spanning capability no snow.It achieves 6 toot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or requires fewer roof attachments, remaining light and economical. maximizing spans up to 8 feet. more for commercial applications. reducing the number of roof 6'spanning capability 8'spanning capability 12'spanning capability penetrations and the amount Moderate load capability Heavy load capability Extreme load capability Clear anodized finish Clear&black anodized finish Clear anodized finish of installation time. Internal splices available Internal splices available Internal splices available Rail Selection IThe following table was prepared in compliance with applicable engineering codes and standards. Values are 1 based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean J Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Rail Span— I _ Force-Stabilizing Curve 1 100 Sloped roofs generate both vertical and lateral 120 forces on mounting rails which can cause them None to bend and twist.The curved shape of XR Rails is specially designed to increase strength in both 140 XR10 directions while resisting the twisting.This unique �� feature ensures greater security during extreme weather and a longer system lifetime. 100 120 1 10-20 140 160 100 30 160 Compatible with Flat &Pitched Roofs Corrosion-Resistant Materials 100 MXR Rails are IronRidge offers All XR Rails are made of marine-grade % 40 compatible with a range of tilt leg aluminum alloy,then protected with an 160 FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing 50-70 160 attachments. applications. a more attractive appearance. 80 9Q 160 i 02014 �/ � L-Mount Installation Instructions L— MountQMLMOMLM —ST Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials,drill with 7/32"or 1/8"bit,drill or impact gun with 1/2"socket_ Elevated Water Seal Technology@ WARNING:QuickMount PV products are NOT designed for and should NOT be used to anchorfall protection equipment. ITEM DESCRIPTION QTY. THIS EDGE TOWARDS ROOF RIDGE NO. FLASHING,ROUNDED CORNERS, 9"X 12"X A40",.438"HOLE,5052, 3rd course 3 1 r�11LL 1 - _ - 2 L-FOOT,2"X 3.30"FOR.438"O.D.FASTENER,2-1116"SLOT,6061- 1 T616005A-T61,MILL � 3. WASHER,SEALING, 511 6"ID X 3/4"O D,EPDM BONDED SS 1 1 1 d LAG SCREW,HEX HEAD,5/76" x 4", 18-8 SS 1 i :5 STRUCTURAL SCREW,QMPV,T-30HEX WASHER HEAD,5116"X4-112", 1 r is-BSS colmse t 2.00 -5 4 Locate,choose,and mark centers of raftersto be Carefully lift composition roof shingle with roofing Insertflashing between 1st and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing is at least-1/4" higher *STRUCTURAL mounts will be placed. nails as required and backfill holes with aproved than the butt-edge of the 3rd course and lower 3•flQ {4.20} 3 SCREW sealant.See"Proper Flashing Placement"on next flashing edge is above the butt-edge of 1st course. AVAILABLE ON page. Mark center for drilling. C�MLM-ST _ 4.50 VERSIONS ONLY 2 9.00 t' f 2.00 1 I :.,.. 0.408 1.00 ® . 2.09 3.30 .90) 1 AVAILABLE IN MILL, � �. . , AND BLACK FINISHES } Quick Mount PVL. 040 TITLE: (3.54) T 42.7� .04 QMLM & QMLM-ST: L-MOUNT, If attaching with lag bolt use a 1/32"bit(Lag).Use a Clean off anysawdust,and fill hole with sealant Place L-foot onto elevated flute and rotate L-footto (22-1/16" SLOT Ya"bit(ST)for attachingwith the structural screw. compatible with fing materials. desired orientation. I11 Drill pilot hole into roof and rafter,taking care to UNLESS DT H ERWIS E S P E CI H ED - drill square to the roof.Do not use mount as a drill QMLM QMLM-ST [AMENSIDNS AREIH INCHES SIZE DRA','+N BY: PAD REV guide.Drill a 2"deep hole into rafter. TOLERANCES FRACP DHAL_I/8: A DATE: 11121/201B 10 THE IH ETWTO,CV,TAIHE IEL TWO PLACE DECIMAL +.IP WRITTEN EOIN iHIS Uff WH NGISTHES. COPYRIGHT OFa DICK MAQLI PJ.ANY REP KPUNI F'11C11uH1N�PAR!'aR.ASA WHOLEWRHOIIi THE DO NOT SALE❑RAWING THREE PLACE DECIMAL ,:,.094 SCALE:I:4 WE GHT:I.G'D9 SHEETI OFI WRITTEN PEPM6SION OFQ111CCkAlIM PJ 19 PPOHBRED. COPYRIGHT®20lfi QUICK MDIINI PV 5 4 3 2 All roofing followedwritten instructions must also be rr anyoner the _17 roof manufacturer's specs and roof.instructions prior to working on the Prepare lag bolt or structural screw with sealing You are now ready for the rack of your choice. quick Mount PV washer. Using a 1/2-inch socket on an impact gun, Follow all the directions of the rack manufacturer drive prepared lag bolt through L-foot until L-foot as well as the module manufacturer. NOTE: Make RESPECT THE ROOF can no longer easily rotate.DO NOT over-torque. sure top of L-Foot makes solid contact with racking. NOTE:Structural screw can be driven with T-30 hex head bit. Bi 7.2.3-44 Dec-2018 Rev 5 817,2.3-44 Dec-2018 Rev 5 8431 Murphy Drive Z99k I R Q N R I D G E Hay Zephyr Avenue Middleton.WI 53562 USA Hayward, CA 94544 1-800-227-9523 Telephone: 608.836.4400 IronRidge.com Facsimile: 608.831.9279 www.intertek.com Attn: David F. Taggart, VP Products, IronRidge Inc. Test Verification of Conformity Date: March 281". 2017 Re: Structural Certification and Span Tables for IronRidge Flush Mount System In the basis of the tests undertaken,the sample(s)of the below product have been found to comply with the requirements of This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush the referenced specifications at the time the tests were carried out. Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof Applicant Name&Address: IronRidge, Inc.1495 Zephyr Ave. attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion Hayward,CA 94544 that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core USA components are shown in Exhibit EX-0015. Product Description: Flush Mount System with XR Rails. The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference standards for the load conditions and configurations tabulated in the attached span tables: Ratings & Principle Fire Class Resistance Rating: Characteristics: -Flush Mount(Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Typel, 2015 International Building Code (IBC-2015) 2 and 3, listed photovoltaic modules. Tested with a 5"gap(distance between the bottom the 2016 California Building Code (CBC-2016) module frame and the roof covering), per the standard this system can be installed at any gap 2015 Aluminum Design Manual (ADM-2015) allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3'rd party roof anchor. The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D. roof zones 1, 2 & 3, and roof Models: IronRidge Flush Mount with XR Rails slopes from 00 to 450. The span tables are applicable provided that the following conditions are met: Brand Name: fronRidge Flush Mount Relevant Standards: UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, fastener) 2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 450 or less. 8431 Murphy Drive Middleton,WI 53562 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from Date of Tests: 08/27/2014 to 03/17/2015 grade. does not exceed 30 feet. Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001arl-crl. This verification is part of the full test report(s)and should be read in conjunction with them.This report does not automatically 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module imply product certification. width shall not exceed 40". Completed by: Chris Zimbrich Reviewed by: Chad Naggs Title: Technician II, Fire Resistance Title: Technician I, Fire Resistance 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. Signature: ��{ Signature: llyy Date: 05/25/2016 Date: 05/2S/2016 This Verification is for the excluswe use of intertek's client and is provided pursuant to the agreement between Intertek and its Client.lntertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material,product,or service is or has ever been ®2017 IronRidge, Inc. CA Flush Mount System Certification Letter- 1 under an Intertek certification program. GFT-OP-11a(24-MAR-2014) 1495 phyr 1495 hyr enue /�� IRONRIDGE Hayward, 544 IRONRIDGE Hayward, 544 Hayward, CA 94544 Hayward, CA 94544 1-800-227-9523 1-800-227-9523 IronRidge.com Iron Ridge.com The parameters and adjustments allowed in the span tables are defined as the following: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-10 Chart 1.5-1. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. 2. When designing with a roof slope not listed in the span tables, but no greater than 45°, the lesser of the two span values listed immediately below and above the desired slope shall be used. For instance. if one is designing to a roof slope of 12°, use the lesser of the two span values associated with 10°and 15° Sincerely, pikOFESS/ON G XU VV 3. The wind speed selection shall conform to ASCE 7-10 Fig. 26.5-1A(Risk Category II wind) and any state & local c3 7y �2 county/city amendments to the IBC. No special wind topographic features are included in the span tables and the C 80829 topographic coefficient (Kzt) is taken as 1.0. 4. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig. 7-1. If a more s� C II. a�P restrictive snow load is imposed by a local building code/amendment to the IBC, such snow load requirement CALIF shall also be complied with. If the local jurisdiction specified snow load is in the format of a flat roof snow load, it Gang Xuan, PE, LEED AP 7 shall first be converted to a ground snow following the local building code/amendment before the application of the attached span tables. No special snow conditions are considered including unbalanced, drifting, sliding or Senior Structural Engineer ponding snow. Snow load conditions presented in the span tables do not include buildings which are intentionally kept below freezing, kept just above freezing, or unheated. 5. The span tables reflect the ASCE 7 prescribed earthquake loads with the maxirnurn magnitudes being: 1) For ground snow no greater than 42psf: SS s 2.Og for Site Class A, B, C, or D. 2) For ground snow greater than 65psf: Ss <_ 1.0g for Site Class A. B, C, or D. 3) For ground snow between 42 and 65psf: Ss s 1.5g for Site Class A, B, C, or D. 6. Roof zone size and definition conforms to ASCE 7-10 Fig. 30.4-2A. 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. 8. An array to roof clearance of 2 inches minimum must be provided. 9. The maximurn cantilever length measured from the rail end to the nearest attachment point shall not exceed 40% of the allowable span provided for the respective load &configuration condition from the span tables. 10. No rail splices are allowed in the cantilever, outer 2/3 of end spans, or middle 1/3 of interior spans. 11. For shaded cells of the span tables, UFO Mid Clamps shall not be installed closer than 20 inches to Roof Zone 3. 12. When a roof attachment listed in IronRidge's Flush Mount installatioa manual is considered, the span values provided in this letter can be adjusted using IronRidge's online Design Assistant by checking the capacity of the selected roof attachment against the reaction forces provided in Design Assistant. ©2017 IronRidge, Inc. CA Flush Mount System Certification Letter-2 0 2017 IronRidge.Inc. CA Flush Mount System Certification Letter-3