Loading...
HomeMy WebLinkAboutBuilding PlansOWEL TO BE TIED BAROW/g48 BARTIDIA LAP SPLICING - TYP. 4° CONCRETE SLAB 86X6,10/10 W.W.M. " CONC. BLOCK - OR FIBER MESH OF N EQUAL STRENGTH ASSUMED GRADE CUT BACK 0 45' ANGLE 6 MIL VAPOR BARRIER %\ CLEAN, COMPACTED (2) ##5 REBARS) TERMITE TREATED ANTIN000S FILL TYPICAL EXTERIOR 0MASONRY WALL I SCALE: 1/2"=1'-O" z 4" CONCRETE SLAB WALL BEYOND 6X6,10/10 W.W.M. OR FIBER MESH OF w EQUAL STRENGTH inx CONCRETE NOTES py � CQ C\, 0vJ A z z 72 0 1 ENGINEER OF RECORD MUST BE NOTIFIED WITHIN 48 HOURS OF PLACING CONCRETE A H H a z 2. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI 301 17'-0" '-4! 12'-.8" V-4" "SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318 BUILDING B w F1 CODE REQUIREMENTS FOR STRUCTURAL CONCRETE:175 a W 3. STRUCTURAL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND c o 0 o $ SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN 28 DAYS OF 3000 PSF. UNLESS -- - - - - - - - - - - - - - - -------- NOTED OTHERWISE. 4. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP .OF4 INCHES PLUS OR MINUS ONE C - ' I VAN. F� INCH. 5. PROVIDE A MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AIR CONDITIONED SPACES & - GARAGES.HOLES IN VAPOR BARRIER ARE NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS. 6. ALL REINFORCING SHALL CONFORM TO ASTM A615 FOR GRADE 60 STEEL/WELDED WIRE MESH TO CONFORM TO ASTM A-185. - '�' I - 6.1. PROVIDE CHAIRS & BOLSTERS 6.1.1. BOLSTERS TO HAVE PLASTIC COATED LEGS & FEET (IF EXPOSED TO EXTERIOR ELEMENTS) I I 13'-4" F� 'o 6.2.. ENSURE MESH IS EMBEDDED 1' FROM THE TOP OF THE SLAB. LAP JOINTS AT 8" & TIE. 7. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A185 AND. SHALL BE ADEQUATELY SUPPORTED @ T-0' O.C. EACH WAY 8. .:THE MINIMUM CONCRETE COVERAGE SHALL BE AS FOLLOWS: ,TIB CAST AGAINST EARTH: 3" I EXPOSED TO EXTERIOR ELEMENTS' 1" N. � ■ ■ ■ ■ ■ w ■ - - - ■ FORMED SURFACES; 1" WE I Cn p I e O f OWE I 9. CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE I I G a ■ VAN WC REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BY THE ENGINEER 0 4" .� I ( FZ �4" 0.4' _I I PRIOR TOCONSTRUCTION OF.THOSE AREAS INVOLVED. - I �- e 'r I "" I I■ 40. CHECK ALL DRAWINGS AND EMBEDDED ITEMS, SUCH MANUFACTURE'S SHOP DRAWINGS FOR I 4 I LOCATION OF ALL EMBEDDED ITEMS, SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC. PRIOR TO PLACING CONCRETE. F5 I I ■ � ] R INFORCEMENT F E 0 B D \/ :. ` \y/\\\ - - - - _ R CONTINUOUS FOOTINGS SHALL E CONTINUOUS AN 5PLICED CUT BACK \ •( . �" \ \\� CUT BACK I. I■ WITH A FULL.30 INCH LAP. PROVIDE CORNER BARS / "`911III III"" 0 45 ANGLE i :,, , \ �//\� ,0 45 ANGLE F� ° -_ 1.2. CONCRETE FOR SLABS ON GRADE AND ELEVATED SLABS SHALL HAVE 3/4" LARGE \ \/ 6 MIL VAPOR I AGGREGATE. "PEAROCK" IS NOT PERMITTED FOR SLABS. i 8" BARRIER rho C 13. ALL CONCRETE THAT IS ALTERED (WATER, ADDITIVES, ETC.) SHALL BE TESTED TO CLEAN, COMPACTED I r ENSURE STRENGTH REQUIREMENTS ARE MET. (2) #5 REBARS TERMITE TREATED I ■ 1^ 14. TERMINATE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI CONTINUOUS FILL L I F1 HOOKS. TYPICAL EXTERIOR WALL 15. SOILS SHALL BE TREATED. AT EXTERIOR DOOR j CONCRETE MASONRY NOTES A I I DRYER WASHER ■ f 2 _ DBL. SINK SCALE.. 1/2 1 0 4 3,000 P.S.I.PSICONCRETE SLAB AT 28 DAYS WITH 6x6,. I ' 1. ALL MASONRY BLOCK SHALL CONFORM TO THE O REQUIREMENTS OF ASTMC90 FOR LOAD I . 4" CONCRETE SLAB I � 10/10 WELDED WIRE FABRIC OR FIBER MESH ON 6 MIL' I BEARING CONCRETE MASONRY. ' I ° POLYETHELENE VAPOR BARRIER OVER CLEAN FILL TREATED I 1.1. MIN. PRISM STRENGTH of 1500 PSI W/ 3/8" MORTAR JOINTS. 8" CONCRETE BLOCK ORXFIBER6,10// 1MESH OF ~ I a a .AGAINST TERMITE INFESTATION COMPACTED TO 95%%% I® 17 2. ALL MORTAR SHALL BE A MINIMUM TYPE M OR S MORTAR •' = EQUAL STRENGTH v I ® 0 PROCTOR DENSITY PER ❑ AASHTO T-180 AND CONTRACTOR 13. UNLESS SPECIFICALLY SHOWN OTHERWISE PROVIDE "DUR-O-WALL' TRUSS TYPE ' I FIN. FLR. SHALL VERIFY THE EXISTING SITE IS CAPABLE OF ' REINFORCING IN EVERY OTHER COURSE. (16" O.C.) ' -. - - I■ 4. ALL LAP SPLICES MUST BE 48 BAR DIAMETERS. ASSUMED GRADE SUPPORTING A MONOLITHIC SLAB GENERATING. A MINIMUM I IN IN '5 WHERE INDEPENDENT CO R TE COLUMNS ARE ABUTTED BY MASONRY WALLS REBAR VERTICAL NEL TO FOOTING. ? // SEE FOUNDATION /\ CUT BACK SHEETS FOR /\\ �•: \\ 0 45"- ANGLE PLACEMENT. 6 MIL VAPOR / / \ BARRIER �//\%CLEAN, COMPACTED (2) #5 REBARS-3\\ '• , / %r TERMITE TREATED CONTINUOUS FILL TYPICAL GARAGE` WALL SCALE: 1/2"=V-0" TYPICAL 4" CONCRETE TT SLAB WITH 6x6, 10/10 W.W.M. �ISLOPE 2" 1 lul 6 MIL VAPOR BARRIER \ CLEAN COMPACTED \//\�20/`\/� ((2 ##5 REBARS TERMITE TREATED CONTINUOUS FILL TYPICAL' STEP DOWN AT GARAGE S SCALE: 1/2"=1'-O" TYPICAL 4" CONCRETE SL78 WITH 6z6, 10 10 W.W.M. SLOPE TO DRAIN _ 6 MIL VAPOR BARRIER CLEAN COMPACTED ((2)) /�5 REBARS CONTINUOUS TERMITE TREATED FILL TYPICAL STEP DOWN 0 NC E. OF 2,000 P.S.F.BEARING PRESSURE PROVIDE DOVETAIL ANCHORS :.FOR THE FULL HEIGHT OF.THE COLUMNS .- X L TUB 6. ALL CONCRETE MASONRY CONSTRUCTION SHALL CONFORM WITH ACI 530.1-05/ASCE 7-05/TMS-602-05, SPECIFICATION FOR CONCRETE MASONRY STRUCTURES AND ACI L �..,. .. - - - 530-05/ASCE 7-05/TMS 402.05,UILDING CODE REQUIREMENTS FOR MASONRY 0'- -0" BSTRUCTURES. ALL CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 WITH -- FIN. FL WC I TYPE M OR S MORTAR COMPLYING TO ASTM C-270. MASONRY UNITS SHALL HAVE F--� O � MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI ON THE NET AREA: (*') O 7. ALL 8" EXTERIOR CMU WALL SHALL BE. REINFORCED WITH #5 VERTICAL REINFORCING 0) VAN. VAN. BARS. WHERE SHOWN ON ARCHITECTURAL PLANS AT CENTER OF GROUTED CELL. cv II I PROVIDE 9.GA. TRUSS TYPE HORIZONTAL JOINT REINFORCING AT 16" O.C. (EVERY f I OTHER COURSE) IN. ALL WALLS.. PROVIDE ADDITIONAL REINFORCING ON EACH SIDE OF �J N E-i cv. 4 I I I I I■ OPENING GREATER THAN 24" WIDE & AT CORNERS & INTER- SECTIONS OF WALLS. CARE E� Vi rx,. 0 SHALL BE TAKEN DURING THE CMU WALL ERECTION TO ENSURE THAT CELLS TO BE ~ I •< GROUTED LINE UP PROPERLY, PROVIDING A MINIMUM CLEAR AREA OF 10 SQUARE � 0 .4 Do Do0'- -4" I I c INCHES & MIN. CLEAR DIM. OF 3" PROVIDE SAW -CUT CLEAN -OUT HOLE IN BOTTOM I- H a a+ L( j (■ GARAGE FIN. FL COURSE &.REMOVE MORTAR DROPPINGS FROM CELLS AT END OF EACH DAY. PROVIDE .Q I ( FOOTING DOWELS TO MATCH WALL REINFORCING SIZE &SPACING.. LAP SPLICEw^ REINFORCING 48 BAR DIA.(OR AS SHOWN ON PLANS) &TERMINATE REINFORCING ^ W I I I F4 I I WITH STANDARD ACI HOOKS TO PROVIDE CONTINUOUS REINFORCING FROM FOOTING ■ TO UPPERMOST TIEBEAMS. TIE VERTICAL REINFORCING TO INSURE PLACEMENT IS IN W W �•'' F1 CENTER OF WALL. A 0 E- F3 I I I I 7.1. WHERE 2 VERTICAL BARS ARE SHOWN IN 1 CELL, INSTALL 1 BAR ON THE a a 0 INTERIOR FACE OF THE WALL & 1 BAR ON THE EXTERIOR FACE OF THE WALL, 2" 1� EW'i m FROM THE EXPOSED FACE OF THE BLOCK.. l0 8. PROVIDE BOND BEAM PER PLANS AROUND PERIMETER OF THE BUILDING@ THE TOP OF rFr-�-yy ^••' I ALL WALLS AND AT JOIST BEARING F�-1f-,1 U1 8.1. BOND BEAM TO HAVE A MINIMUM OF (2) #5 BARS OR (1) #7 BAR TOP AND F•� I ®--® ■---- ■ _ WI I 1 I BOTTOM (UNLESS OTHERWISE NOTED). F­i / \ I 4" ■ I - - - - - - - - _ - _ ■ 8.2. H-BLOCK TIE BEAM .STEEL TO STOP 8" FROM CORNERS. WITH (1) #5 CORNER BAR � i \ L > ■ ■ ■ ■ ■ (OR 1.#7) TOP & BOTTOM 32" MIN. LAP. rr + -J-}- I F� �• I I■ b S, VERTICAL REINFORCEMENT STEEL TO HAVE A 1/2" MIN. CLEARANCE FROM MASONRY. F� --- 15'-10° ��-2. ■ _1 10. .GROUTED CELLS SHALL NOT EXCEED A 12' CONTINUOUS POUR. �' m F2 ■ ■ ■ ■ ■ F1 `� 11. PROVIDE 'CAST-CRETE" (OR APPROVED EQUAL) PRECAST CONCRETE LINTELS AT ALL �I MASONRY OPENINGS, UNLESS NOTED OTHERWISE. I2. ANY EPDXY SHOWN SHALL BE EITHER "HILTI HIT RE 500" WITH "HAS-0 THREADED F3 r.; F� •wj ,. `. RODS FOR MASONRY OR "SIMPSON XP22" WITH THREADED ROD. liti12.1. .ALL THREADED ROD HOLES TO BE 1/8" DIA. LARGER THAN REINFORCING STEEL r- O --- - ----- io OR THREADED ROD FOR EASE OF INSTALLATION. r- C') rn F6 FOUNDATION NOTES A� o 3'-8" - -- 16'-0" 3'-8" 6 8 13'-5" 15'-8" 1. SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY Q i U C/D 0) C1 23'-1- - 11-11 7'-8 29'�1" ASTM 1557 (MODIFIED PROCTOR). W LrJ 0) 2. FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING W Ci P 0) -- - 72'-0" PRESSURE OF 2000 PSF ` 'ZHZ J CO 3. FOOTINGS SHALL. BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS. Z ~ [� FOUNDATION PLAN LLo SCALE: 1 /4„ = 1 -0" EDFOR xaw� AT SHOWER REVIEW 1 a-4� 4" CONCRETE SLAB WALL BEYOND X6,10/10 W.W.M, JOINT � i'-2" OR FIBEk MESH OF EQUAL STRENGTH CODE COMPLIA! � z 0 ST. L.UCIE COUN I; Fa BOC F" q 1/2 EXPANSION /�, CUT BACK \\'/j\\ 0 45• ANGLE 6 MIL VAPOR L L 1 I I I 1 +" a COpY .BARRIER \ CLEAN, COMPACTED (2) #5 REBARS TERMITE TREATED LEGEND ANTINUOUS WINDOWOPENING ' a TYPICAL GARAGE RECESS SCALE: 1/2"=1'-0 Mill tt� TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE COMPLIES AND HAS BEEN DESIGNED IN ACCORDANCE WITH SECTION 1609 OF THE 7th EDITION FL. BLDG. CODE TODD N. SMITH, P.E., FL. PE #42082 68'-8" GENERAL NOTES DESIGN PARAMETERS FOR VVIND LOAD COMPLIANCE 7' 1. CONTRACTOR SHALL VERIFY ALL. DIMENSIONS PRIOR TO 1. BUILDING CATEGORY II 25'-4° - 12'-4" 17'-8"-13'-4" CONSTRUCTION. IF THE CONTRACTOR OBSERVES THAT THE 2, FLORIDA BUILDING CODE 7TH EDITION (2020) ,, DRAWINGSAND SPECIFICATIONS ARE ATVARIANCE THEREWITH, HE.. 3. BUILDING DESIGN. IS ENCLOSED +37.8 +37.8 -50-3 SHALL PROMPTLY NOTIFY THE ENGINEER IN WRITING, AND FORY 4. MEAN ROOF HEIGHT IS 15' -41.0 � NECESSARY CHANGES SHALL BE ADJUSTED AS PROVIDED FOR ti 2050 2050 2'-10" CHANGES IN THE WORK. 5. ROOF PITCH 5/12 DEGREES it 2. THE DESIGN & CONSTRUCTION OF THIS STRUCTURE MUST FULLY 6. INTERNAL PRESSURE COEFFICIENT +/-.0.18 COMPLY WITH THE SEVENTH EDITION. OF THE(2020) FLORIDA 7, WIDTH OF END ZONE A = 3.33' ` ao �.. LE-G BUILDINGCODE, ACI318-05, NCMA, NATIONAL FORESTPRODUCT w8. WIND SPEED IS 170 MPH 3 SECOND GUST o m ASSOC., NDS, TPI-95, AND ANY OTHER NATIONALLY RECOGNIZED WIND EXP RE TI N.o ORGANIZATIONS THAT GOVERN THIS BODY OF WORK.9• OSU CLASSIFICA O C o 10. COMPONENT & CLADDING ULTIMATE WIND PRESSURE ON ROOF: 3, THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY. WITH ALL60 +36.0 -LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE COMPONENT & CLADDING NOMINAL WINDPRESSURE ON WALL: -47.2CONDUCT OF THE WORK AS: DRAWN AND SPECIFIED AND SHALL BE COMPONENT & CLADDING WIND PRESSURE ON SOFFITS50 3050 BB PERMITTED AT THE. LOCAL OFFICE, COUNTY OR CITY. THE RESULT , ..(SEE CHART ON RIGHT ON THIS PAGE) OF NOT OBTAINING A BUILDING PERMIT FOR THE DESIGN OF THESE 1l.. LOADS: PLANS SHALL RELEASE ALL RESPONSIBILITY FOR THIS PROJECT FLOOR 40 PSF Master -- ------ ----------------------------------------- " � FROM THE ENGINEER OF RECORD. CONTACTOR IS RESPONSIBLE M. Bedroom FOR A FINAL CERTIFICATE OF OCCUPANCY FOR THIS PROJECT. ROOF/DEAD 17 PSF +R O o Bath Co � � � � 4. IF THE CONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE ROOF/LIVE 20 PSF N I Porch -41.0 in - i +37.8 GLASS MUST In CONTRARY TO SUCH LAWS, ORDINANCES, RULES AND WALL 61 PSF 50.3 BE TEMPERED RUGULATIONS, AND WITHOUT SUCH NOTICE TO THE ENGINEER, HE 12. SHEAR WALLS WERE CONSIDERED 9'-6" 14'-2" i 2 PER F.B.C. 308.4 - SHALL BEAR ALL COSTS ARISING. THEREFROM. 12'-0" 13 A CONTINUOUS LOAD PATH WAS PROVIDED CC 5.. THESE PLANS WERE DESIGNED FOR THE CONTRACTOR/OWNERTO ' • . • b p _l; - BE PERMITTED AT THE LOCAL AGENCY (BUILDING DEPARTMENT AN D.: 14. COMPONENT & CLADDING DETAILED GLASS MUST +36.0 O SHOULD BE FOLLOWED As INSTRUCTED. THE RESULT OF NOT 15. MINIMUM SOIL BEARING PRESSURE IS 2000 PSF PRESUMPTIVE BE TEMPERED 1 /2 O -39.3 OBTAINING BUILDING PERMIT FOR THE DESIGN OF THESE PLANS PER F.B.C. 308.4 Wall q 4'_0" SHALL RELISH ALL RESPONSIBILITY FROM THE ENGINEER OF z-1o" 12'-0" 2'-10' 10 TIMBER NOTES d Dinningo RECORD. - ' I +36.0 � ;1 6. ` TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS FOR ro ` , :BUILDERS APPROVAL. THESE DRAWINGS SHALL BE SEALED BY.A 1.: PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY A FLORIDA (D 12068 -47.2 c i 7 -8. - FLORIDA REGISTERED ENGINEER AND REVIEWED BY THE ENGINEER REGISTERED ENGINEER FOR ALL LOADS PRESCRIBED. ROOF TRUSS ENGINEERING. OF RECORD. THE ENGINEER OF RECORD RESERVES THE RIGHT TO SHOP DRAWINGS SHALL INCLUDE TRUSS LAYOUT, DESIGN LOADS TRUSS 2868 2868 +32.1. 2468 MAKE ANY NECESSARY CHANGES TO. THE LAYOUT AND OR DESIGN REACTION, (DEAD LOAD & LIVE LOAD AND DEAD LOAD & WIND LOAD), AND ALL -35:3 2868 OF SAID DRAWINGS, AND SHALL NOTIFY THE TRUSS OTHER INFORMATION . REQUIRED FOR PROPER TRUSS INSTALLATION, ERECTION N : .MANUFACTURER/ TRUSS ENGINEER OF SAID CHANGES WITHIN 1 , AND BRACING CRITERIA. DESIGN OF ROOF TRUSSES SHALL INCLUDE THE UPLIFT 00 Oven / . WEEK OF RECEIVING THE SUBMITTED SHOP DRAWINGS... EFFECTS OF WIND LOAD BASED ON THE 7th EDITION OF THE FLORIDA C Micro 7. WEATHERING AREA IS NEGLIGIBLE RESIDENTIAL BUILDING CODE. _ 12'-2". •r 8: - TERMITE AREA IS VERY HEAVY 1.1. ROOF TRUSSES SHALL NOT BE DELIVERED TO THE CONSTRUCTION SITE ,___:::____ _ r 9, PROTECTION FROM TERMITES SHALL BE PROVIDED BY REGISTERED MORE THAN 3 DAYS PRIOR TO INSTALLATION, AND SHALL BE STORED IN.. 5-4 -4 0 Family EGRESS 'TERMITICIDES. ACCORDANCE WITH TPI-95. i 0 Room 10. THE FLOOR OF THE GARAGE OR CARPORT SHALL 8E SLOPED W „ -� +36.0 / 1.2. TRUSS ENGINEER SHALL PROVIDE A WEB MEMBER AT ANY AND ALL PITCH ' A/C 5 -8 I Bedroom o o NATURAL CONCRETE OR PAINTED WITH A NONCOMBUSTIBLE CHANGES OF THE TOP b BOTTOM CHORD EXTENDING TO PANEL POINT t O Pdntr ro L -- I M 39.3 O AN MATERIAL. ON OPPOSITE CHORD. MAX. LENGTH OF BOTTOM CHORD SHALL NOT • y N Ceilln g S 3 a 11: .'HEATING IS REQUIRED FOR THIS STRUCTURE. 5 -8 Q EXCEED 9 FT. EXCEPT@ SHORT TRUSS HEELS WHERE REQUIRED ' " 12. BEDROOMS SHALL HAVE AN EGRESS OPENING OF 5 SQUARE FEET. HURRICANE STRAP WILL BEND OVER TOP CHORD. PROVIDE VERTICAL WEB . ........, .. 9 " �a WINDOWS SHALL HAVE A 24" CLEAR HEIGHT WITH A 20" NET CLEAR OVERALL TRUSS BEARING LOCATIONS. WIDTH OR GREATER. MAXIMUM SILL HEIGHT IS 44" FROM FINISH 1.3. ALL MEMBERS SHALL BE A MINIMUM OF 2 X 4 #2 SYP. ' ' D W32+.: 6' 3 4 FLOOR. 1.4-. ALL VALLEY SETS SHALL BE FRAMED WITH VALLEY SET TRUSSES AND 13, ` ALL EXIT DOORS SHALL HAVE A LIGHT W/ A FLAT 36 X 36 ATTACHED TO TRUSSES BELOW PER SPECIFIED STRAPPING @ 6 A.C. MAX. j till a .:LANDING. ROOF PLYWOOD SHALL EXTEND. ON TRUSSES BENEATH ALL OVER FRAMING. o 6'-0 ,. 14. ` SMOKE DETECTORS SHALL BE INSTALLED INSIDE AND OUTSIDE OF OMIT PLYWOOD AND VALLEY SET BOTTOM CHORD BETWEEN TWO TRUSSES • - - EACH BEDROOM. FOR MULTIPLE STORY RESIDENCES THE SMOKE FOR ACCESS. °J 7 7 2868 . • • • . • • . ......... • • . • • • • DETECTORS SHALL BE INTERCONNECTED. SMOKE DETECTORS I.S. IN ADDITION TO THE DESIGN LOADS LISTED, THE TRUSSES SHALL BE - 12'-0"J- o SHALL BE HARD WIRED FOR NEW CONSTRUCTION. DESIGNED FOR ADDITIONAL LOADS WHERE APPLICABLE (LE. A/C c07o o Both 2 .I 15: :WALL AND CEILING FINISHES SHALL HAVE AFLAME -SPREAD EQUIPMENT, ETC.) +36.0 Laundry d � n CLASSIFICATION OF NOT GREATER THAN 200'AND HAVE A S.G. DESIGN BOTTOM CHORDS FOR ATTIC TRUSSES FOR LIVE LOAD PER 7th o -39.3 Kitchen +37.8 SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. EDITION FBC R301,5. TRUSSES SUPPORTING MECHANICAL EQUIP. SHALL BE ONO_I : 2868 N - n -5-0 3 16. INSULATION MATERIALS SHALL HAVE A FLAME SPREAD NOT TO DESIGNED FOR (2) 100 LB POINT LOADS T APART LOCATED ANYWHERE ON .................. „ 00 - EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPMENT INDEX . . THE TOP CHORD: ,q /H • • " NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM 1.T : TRUSSES MUST BE CONFIGURED TO PROPERLY ATTACH ALL HANGERS WH rT-- Z, E84. ALL EXPOSED ATTIC INSULATION MATERIALS` INSTALLED ON: .SHOWN ON PLANS OR IN SHOP DRAWINGS. TRUSS ENGINEER MUST.< O , �❑no N "' """ """"""""' """ ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX (IN .SPECIFY ALL TRUSS TO TRUSS CONNECTIONS. Co ACCORDANCE WITH ASTM E 970) NOT LESS THAN 0.12 WATT PER 1.?. ALL ROOF TRUSSES AND RAFTERS SHALL BE ANCHORED WITH A:TRUSS 20 MIN. FIRE RATED -� ...................... • . • • • .. • • Co SQUARE CENTIMETER. CONNECTOR STRAP AS PER PLAN :OR SCHEDULE & A VAPOR. BARRIER MUST 17.. A VAPOR RETARDER SHALL E INSTALLED IN THE WARM WINTER " B I S BE PROVIDED BETWEEN TRUSSES AND CONCRETE. I I DOOR W/ AUTOMAT C,- a :; 8068 " +36.0 r • - . •r, .SIDE OF THEINSULATION. SHOULD BLOWN INSULATION BE USED IN SELF CLOSING HARDWARE ' 3'-11" 2. ROOF SHEATHING SHALL BE A MIN. OF 5/8" COX SPAN RATED STRUCTURAL -39.3 °n,c IL JI : (0 _ ? THE ATTIC, A VAPOR RETARDER MUST BE USED. PLYWOOD, INSTALLED WITH FACE GRAIN PERPENDICULAR TO ROOF FRAMING00 . 1 N � 1 18 ALL WOOD -FRAMING MEMBERS RESTING ON CONCRETE OR WITH 10d RING SHANK NAILS 4" D.C. AT PANEL EDGES AND 8" O.C. IN THE FIELD. "D MASONRY SHALL BE PRESSURE TREATING WITH FASTENERS OF `PROVIDE 2".X 4" BLOCKING AT HIPS AND VALLEYS. SPACE NAILS AT 4" O.C. AT 24�x30" ATTIC a HOT -DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS G BLOCKING ACCESS 11' 2" STEEL. PROTECTION FROM DECAY SHALL BE REQUIRED PER FBC 3. WALL SHEATHING TO BE 1/2" CDX SPAN RATED STRUCTURAL PLYWOOD, & NAILED + •.; - :.Den � � .� . R-319.1. WITH lOd NAILS 4" O.C. AT PANEL EDGES AND 8" O.C. IN THE FIELD. 19, : ACCESSIBILITY DOORS SHALL HAVE A 29" MIN. CLEARANCE. 4. THE"MINIMUM LUMBER GRADES. SHALL BE AS SUCH: of Gd r0 ge Bedroom 0. I Bedroom 20. THE SITE ADDRESS OR NUMBERS SHALL BE PLAINLY VISIBLE AND -INT. BEARING WALLS, TOP PLATES SHALL BE CONSTRUCTION GRADE SPRUCE OR 0 2 LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. BETTER. HEADERS SHALL BE 2X12 #2 SOUTHERN YELLOW PINE & 2X4 MIN. IN o 22 0 1 '� 21.. AT LEAST ONE BATHROOM SHALL HAVE AMINIMUM OF A`29" CLEAR. MASTER BEDROOM BAY. - 41.2'-5" : OPENING. WINDOW .BUCKS AND BOTTOM PLATES AGAINST CONCRETE SHALL BE PRESSURE 00 -I tO 3050 22. ALL STRUCTURE FOOTERS SHALL BE.A MINIMUM OF 12" BELOW TREATED SOUTHERN YELLOW PINE #2 OR BETTERF_ y 04 F+36 01 GRADE. 5... ALL TIMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL. BE PRESSURE 23. FOUNDATION STEEL (#5 BARS)SHALL HAVE A MINIMUM OF 3' OF TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. -39.3 EGRESS COVER, 6. 2X4 STUD BEARING WALLS SHALL BE PLACED AT 16" O.C. EGRESS 24. A CONTINUOUS PATH FROM FOUNDATION TO ROOF SHALL BE 0 5068 7. .ALL NAILS. AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE 3050 3050 1 12'.-7'F PROVIDED PER DETAILS AND CONNECTIONS SPECIFIED. GALVANIZED. ALL NAILS SHALLBE COMMON WIRE NAILS. SPACE NAILS: AT STRAPS +360 0 +36,0. +36:0 0 25. ALL. FRAMED BEARING WALLS SHALL HAVE A MINIMUM OF 2 - 2"X12" AS TO NOT SPLIT THE WOOD. ` -47.2 -39.3 j -47•2 7 EGRESS I #2 SOUTHERN YELLOW PINE HEADERS W/ 3/8"TO 1/2" PLYWOOD AA I EN RYa 26. ROOF AND WALL COMPONENT AND CLADDING LOADS ARE SHOWN WINDOWS & DOORS NOTES co , 3050 I� 5'-4" IN THE DESIGN CRITERIA.. • - I I +36.0 27. SHUTTERS OR IMPACT GLASS IS REQUIRED FOR PROTECTION OF 3 -2 h -39.3 OPENINGS FOR THIS RESIDENCE PER SECTION R301.2.1.2 OF THE 1. WINDOWS, DOOR, SHUTTERS, AND ALL COMPONENTS SHALL BE DESIGNED AND L -------- --------- INSTALLED PER THE MINIMUM DESIGN PRESSURES AS PRESCRIBED IN THESE 5'-0" FLORIDA RESIDENTIAL BUILDING CODE_ ...PLANS. 28. INTERIOR AND BEARING AND NON -BEARING FRAMED WALLS SHALL 7'-8" 2. ALL EXTERIOR GLAZING SHALL BE IMPACT RESISTANT OR HAVE PROTECTION PER 16070 A A USE STUD GRADE LUMBER SPACED AT 16" O.C.. SECTION R301.2.1.2 OF THE 2014 FBC RESIDENTIAL. PROTECTION SHALL BE +31-9 5 -10 29. FRAMED BEARING WALLS SHALL BE BRACED WITH 2X4S @ A DESIGNED FOR THE SAME WIND DESIGN PRESSURES AS THE WINDOWS OR -35.6 MAXIMUM OF 8' O.C. DOORS THEY ARE COVERING. 30. ROOF SHEATHING SHALL BE 5/8" COX AND HAVE A SPAN RATING OF 3ALL WINDOWS & DOORS ARE TO BE INSTALLED ON 2X PRESSURE TREATED 16/24 AND NAILED WITH IOD NAILS RING OR SCREW TYPE NAILS (2 BUCKS,.: AND AS PER MANUFACTURERS SPECIFICATIONS UNLESS OTHERWISE 23'_¢" 19'-0" 14'-0" 15'-8' 1/2" X .131") AT 4" O.C. ON THE SEAMS AND 6' O.C. IN THE, FIELD. NOTED, 31. ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL. " 72'-0„ CONFORM TO ASTM C36, C79, C 475, C514, C630, C9311 C960, ROOFING NOTES D I � r- n VI I � I O ^ ' � �NI C1002, C1047, C1177, C1178, C1278, C1395-0R C1396 AND SHALL � \ IN ICI AREA INFORMATION SCALE: 1/4 ,p = 1 141 FIRST FLOOR COMPONENT & CLADDING NOMINAL PRESSURES: ASCE 7-16 (170 MPH Vult) (132 MPH Vasd) EXP.'C' HIP ROOF SLOPE: >20" TO 270 (4 1/2" TO 6" PITCH) HEIGHT: <15' ADJUSTMENT FACTOR: 1.21 EFFECTIVE AREA (SQ. FT.) ZONE 0<10 11<20 21<50 51<100 4 +37.8 41.0 +36.0 -39.3 +33.9 -37.1 +32.1 -35.3 `3 N 5 +37.8 -50.3 +36.0 -47.2 +33.9 -42.7 +32.1 -39.3 1. +28.2 -50.6 +24.4 -44.8 +14 3 -37.1 +15A -31.4 o - .2e +28.2 -69.7 +24.4 -62.4 +19 3 52.6. +15.4 -45.2 2r +28.2 -69.7 +24.4 -62.4 + 9 3 52.6 +15.4 -45.2 . 3e +28.2 -69.7 +24.4 -62.4 +19.3 -52.6 +15.4 -45.2 1 :-64.0 -64.0 -61.8 -60.2 Wz 2e -64.0 -64.0 -61.5 -59.8 of 2n -96.0 -89.5 -80.8 _ -74.2 2r -96.0 : -89.5 -80.8 -74.2 3e -115.2 -96.9 -72.7 -54.4 , 3r r -133.4 -110.4 -80.0 -80.0. LIVING AREA U/A 2,513 sq.ft. IN INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 702.3 OF THE CURRENT FLORIDA RESIDENTIAL BUILDING CODE. 1. .ROOFING MATERIAL SHALL BE ATTACHED PER MANUFACTU S , PE IFICAT NS O� ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL ': G1N PtW T p►N�+ ' TO MEET THE DESIGN CRITERIA PRESCRIBED IN THESE P 1✓'�'`j+,V1.[- V CONFORM TO ASTM C557. rx 32. CERAMIC TILE SURFACES SHALL BE INSTALLED IN ACCORDANCE �« PLI l�"'.' WITH ANSI A108.1, A108.4, A108.5, A108,6, A108.11, A118.1, - L cite OV A118 3 A136 1 AND A1371 WALL TILE SHALL HAVE EITHER': "� W REAR PORCH GARAGE 176 482 sq.ft. sq.ft. CEMENT; FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN IN IBv~%,0 ENTRY 56 sq.ft. COMPLIANCE WITH ASTM C1288, C135 OR C1178 AND INSTALLED WALL LEGEND � 1OD ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS SHALL TOTAL 3,227 sq.ft. BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS. • „ •.• ,;33. ACCESS OPENING SHALL BE A MINUMUN OF 16" X 24" AND SHALL NOT BE UNDER A EXTERIOR DOOR OR LOCATED BEHIND AN ....'... ....._... ...... EXTERIOR FIXTURE. 34. :ALL NAILS SHALL BE HOT DIPPED GALVANIZED OR BETTER. 35. ALL SIMPSON FASTENERS SHALL BE Z-MAX WITH HOT-DIPPEDGALVANIZED COMMON NAILS OR BETTER.36. DMEANROOF ALL BEARING WALLS SHALL HAVEA SIMPSON SPH4 6 PLACED TOP O NOA D BOTTOM OF FRAMED WALL AT i6" O.C...HEADERS OVER 4' G SHALL BE STRAPPED TO JACKS W/ SIMPSON MSTA24 AT ENDS WJ N0: 8-10d NAILS PER SIDE. HEADERS UNDER 4' SHALL BE STRAPPED W/ 1 SIMPSON LSTA18 W/ 7-10d NAILS PER END. EACH JACK SHALL HAVE.. =,k: " A.H2.5A @ THE BOTTOM PLATE. - STA 37. 38, CONTRACTOR TO VERIFY ALL DIMENSIONS AND ROOF PITCH. NO SCREWS SHALL BE USED IN THE PLYWOOD SHEATHING OR •o'•, .✓hO WIND :DESIGN ZONES WOOD MEMBERS OR ANY SIMPSON PRODUCTS UNLESS SPECIFIED SCALE: NTS IN THESE PLANS OR. FROM THE MANUFACTURER. 39 ROOF RAIN WATER SHALL BE DIVERTED FROM SEPTIC FIELD 40. THERE SHALL BE A SELF CLOSING 20 MINUTE FIRE -RATED BETWEEN REVISIONS THE GARAGE AND THE LIVING AREA.. 1. PER ST. LUCIE COUNTY DSP 4-9-21 TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE COMPLIES AND HAS BEEN DESIGNED III ACCORDANCE WITH SECTION 1609 OF THE 7th EDITION FL BLDG. CODE LO r� E"'1 h- Z e� a w Nw W 6 7/l O F-i-•I O PE-4 aJ CQ Co O - C\2 .� O rE­r O W x CO F� ��-� w ' pq W¢W~'II FT;Q�� h�- U) L �j pLj + C\2 C\2 E- O DO CrJ ZkW O W C\2 ' M CD Z CD � C`7 CO _M I W W LO p, U LCO I W �yxa�� ND H O U) P4 U zz U] Q 0.. e�-1 204K TODD N. SMITH, P.E., FL. PE #42082 All flood fits /conned 0 GTv �\ \\ Master Bedroom \--------------------------- ------------------------------ n \ M. CE Both \ G,M I \ \ Porch \ \ Dinning 'i o, \ I \ \ LG ELECTRICAL LEGEND ---` RECESSED INCANDESCENT 220 V. RECEPTACLE 1 \ LIGHT FIXTURE \Oven 110 V. RECEPTACLE \ \ Micro / / / / \ \ / \ \ EXHAUST FAN ------_ - / \ Bedroom 3 GFl GROUND FAULT INTERRUPTER \ CE Fol COMBINATION EXHAUST FAN & WF WEATHER PROOF INCANDESCENT LIGHT FIXTURE ----------- 1 / Family Room \ WALL MOUNTED $ LIGHT SWITCH / \ INCANDESCENT LIGHT FIXTURE $3 THREE-WAY SWITCH Pantry / c.G.o. GARAGE DOOR OPENER o aI DISCONNECT D WL I 0 1 �� I Ceilings ® HIGH INTENSITY DOWN LIGHT ' a / I 9 - 4 I Itot / CEILING FAN I N FLaundryj �a CEILING MOUNTED SMOKE/ CARBONDIOXIDE DETECTOCEILING FAN WITH LIGHT � FLOOD LIGRIS \ \ / / Bath 2 3 IFLOUR. LIGHT FIXTURE (1 TUBE)E� \ ELECTRICAL METER w A�H�' / Kitchen n\I�/ ® GF C • 'LOAD SUMMARY GENERAL LOAD WATTS AMPS WIRE TOTAL WATTS GENERAL LIGHTING AND RECEPTACLES 2,513 TOTAL S.F. 3 PER SQ. FT. 15 12 7,539 APPLIANCE CKT. (2) 1,500 PER APPL. 20 12 3,000 REFRIGERATOR 1,500 PER UNIT 20 12 1,500 RANGE 8,000 PER UNIT 30 10 1 8,000 BATHROOM 1.500 PER UNIT 50 8 1,500 DISHWASHER & DISPOSAL 1,500 PER UNIT 20 12 1,500 DRYER 5,000 PER UNIT 30 10 5,000 LAUNDRY 1,500 PER UNIT 20 12 1,500 WATER HEATER 4,500 PER UNIT 1 30 10 4,500 SPRINKLER PUMP 2,000 PER UNIT 1 20 12 2,000' SUB -TOTAL 38,039 1st 10,000 WATTS 0100 % 10,000 REMAINDER WATTS 0 40 % 28,039 A/C HEAT ® 100% 10,000 TOTAL WATTS 31,215 TOTAL WATTS = 240 V. _ 130 AMPS ELECTRIC NOTES: 1. ALL OUTLETS SHALL BE ARC -FAULT PROTECTED. 2. ALL ELECTRIC SHALL CONFORM TO THE CURRENT NATIONAL ELECTRIC CODE. 3. ELECTRIC METER PER LOCATION OF SERVICE POLE. 4. ATTIC ACCESS SHALL HAVE A SWITCH AND LIGHT. 5. SMOKE DETECTORS SHALL BE CARBON MONOXIDE DETECTORS (PER FLORIDA STATUES 553.885) AND BE LISTED IN ACCORDANCE WITH UL 217 AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND SHALL BE HARD WIRED IN EACH SLEEPING ROOM AND OUTSIDE IN THE HALL OF THE IMMEDIATE VICINITY OF THE BEDROOMS 6. EXTERIOR LIGHTS AND OUTLETS TO BE LOCATED IN FLAT OF EXTERIOR SIDING. EXTERIOR OUTLETS SHALL BE GFI (GROUND FAULT CIRCUIT INTERRUPTER) WITH WEATHER PROOF COVERS (WP). 7. KITCHEN GFI (GROUND FAULT CIRCUIT INTERRUPTER) OUTLETS ABOVE COUNTER SHALL BE LOCATED 44" OFF FINISH FLOOR (OFF). REFRIGERATE OUTLET SHALL BE 48" OF. 8. PROVIDE 2X4 BLOCKING OR EQUAL SUPPORT IN CEILING LIGHTS IN BEDROOMS & LIVING ROOM. 9. LOCATION OF FIXTURES AND/OR OUTLETS ARE SUGGESTED AND MAY BE ADJUSTED BY OWNER/ BUILDER BUT SHALL REMAIN WITHIN ALL LOCAL AND STATE GUIDE LINES. 10. TELEPHONE AND CABLE TV LOCATIONS ARE NOT SHOWN. 4 POWER CO. METER RUN 1 #4 CU TO 5/8" GROUND RON AND COLD 2-4/0 1-2/0 MCM THW AI_ IN 2" IMC 120/240 10 3W NEMA 31? 200 AMP. 10K AIC ENCLOSED CIRCUIT BREAKER ONLY WHEN EXTERIOR UNIT IS REQ'D. ELSE: 200 AMP. MAIN BREAKER PANEL 120/240 10 3W NEMAI 20OAMP. MLO FLUSH MOUNT PANEL 2-4/0 1-2/0 MCM THW Al WATER PIPE SERVICE CABLE NOTE; ALL ELECTRICAL MATERIALS AND INSTALATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NATIONAL ELECTRIC CODE, LOCAL ORDINANCES, FLORIDA POWER & LIGHT. ELECTRICAL RISER DIM REVISIONS 1. PER ST. LUCIE COUNTY DSP 4-9-21 'RAM ELETRICAL SCALE; PLAN 1 /A" — V__npl nearoan'l I ii / 11 ucUi vvi i i c H LO G4�� W co - 'Z 4-1 � a � pq w�a C0 0) G\2 Fi c CASING BEADS, 1/8 INCH SEPARATION , STUCCO INSTALLATION INFORMATION SPACE -BAKER ROD AND CAULK 7.11.4.1 WALLS - DELINEATE AREAS MAX. 144 SQFT . FBC BUILDING 2510 AND 2512 CEILINGS -MAX. 100 SQFT 6" ��0 Na0" 6" 6" 1'-4" 6 C K @MASONRY �`—�` Max � FBC RESIDENTIAL 703.6 AND 704 7.11.4.2 DISTANCE BETWEEN CONTROL JOINTS MAX. 18 FT EITHER DIRECTION OR LENGTH B U ASTM C926-98A (2005) TO WIDTH RATIO 2% TO 1 OPENINGS D ASTM 1063-06 (18 FT LONG AND 4 FT HIGH = 18/4=4.5 RATIO LONG SIDE: SHORT SIDE - CMU SOLD BASE -LATH AND ACCESSORY INSPECTION REQUIRED RATIO, WHICH MEANS IT EXCEEDS THE 2 %:1 RATIO, 18 FT LENGTH IS TOO LONG FOR THE CEILINGS, SOFFITS, ENTRIES, GABLES, PENETRATIONS, OPENINGS, DISSIMILAR MATERIALS, 4 FT HEIGHT BETWEEN CONTROL JOINTS) WINDOWS -' ETC CONTROL JOINTS IN CEILINGS - FRAMING CHANGES DIRECTION 2" X 4" P.T. WINDOW BUCKS SHALL BE ATTACHED TO THE MASONRY C926 A2.1.4 DISSIMILAR MATERIAL -V-JOINT IN LIEU OF CASING BEAD 7.11.5 FOUNDATION WEEP SCREED WALL WITH 3/16" DIA. X 3 3/4" TAPCONS AT 12" O.C. ON THE SIDES WINDOW OPENING - OR METAL DOOR AND WINDOW FRAMES STUCCO ABUTS WOOD. BOTTOM OF ALL STEEL OR WOOD FRAMED EXTERIOR WALLS BO O AND ON THE TOP OF THE OPENING. IN MASONRY WALL THREE COAT -THROUGH SECOND AND FIRST COAT -% INCH V-JOINT BOTTOM EDGE MIN. 1 INCH BELOW JOINT, NOSE OF SCREED MIN. 4 INCH (FBCR 6 1X BUCKS MAY BE USED ONLY W/ 3/16" DIA: TAPCONS @ 12" D.C. TWO COAT -THROUGH FINISH COAT-1/8 INCH V-JOINT INCH MORE STRINGENT) ABOVE GRADE OR PENETRATING 1 1/2" MIN. INTO THE MASONRY WALL , V-JOINT MUST BE UNIFORM DEPTH AND WIDTH 2 INCH ABOVE PAVED SURFACES o o g 1 INCH BELOW JOINT APPLIES TO MID WALL WEEP SCREED AS WELL BUCK ATTACHMENT OPTION (WINDOWS) 3/16" TAPCONS INTO PLYWOOD WEATHER RESISTIVE BARRIER AND LATH SHALL ENTIRELY COVER THE VERTICAL PRE -MANUFACTURED HOLE PENETRATING INTO THE MASONRY WALL 1 C1063 TABLE 3 NOTE A - PLYWOOD REQUIRES 1/8 INCH GAP BETWEEN ADJOINING SHEETS FLANGE 1/2" MIN. FOR EXPANSION (ENDS AND SIDES) FBCR 704 REQUIRES MIN. 6 INCH BETWEEN EXTERIOR WALL COVERING AND T 6"j, 1'-0" � 1'-O" 6" GRADE -STEEL, WOOD OR CMU DOORS - aax. n ax. FASTENERS - ASTM C1063 NAIL SIZE AND TYPE- (NO DOUBLE NAILING iN LIEU OF EXCEPTION #1 PAINT OR DECORATIVE CEMENT ROUS FINISH DCF (JUST FOR 2X DOOR BUCKS SHALL BE ATTACHED WITH 3/16" TAPCON ANCHORS @ COMPUANCE) - COSMETICS) LESS THAN 5/8 INCH THICK 16" O.C. PENETRATING 1 1/2" MIN.. INTO THE MASONRY WALL 6.7.1 NAILS -METAL LATH TO WOOD 0.01205 INCH -11 GAUGE W/ 7/16 INCH HEAD, CMU -SOUD BASE -CAN BE TERMINATED WITH A J CHANNEL OR CUT IT IS SX BUCKS MAY BE USED ONLY W/ 3/16" DIA. TAPCONS @ 15" O.C. BARBED, GALVANIZED ROOFING NAILS OR GALVANIZED COMMON NAILS JUST A TERMINATION POINT PENETRATING 1 1/2" MIN. INTO THE MASONRY WALL 6.7.1.1 NAILS -LATH TO SOLID SUBSTRATES %INCH LONG NOTE: OPTIONAL ACCEPTABLE METHOD FOR STUCCO BELOW GRADE 6.7.2 SCREWS -LATH 7/16 INCH PAN WAFER HEAD 0.120 INCH DIA. SHANK 1. LESS THAN 5/8 INCH STUCCO CAN EXTEND BELOW GRADE IF THE BUCK ATTACHMENT OPTION (DOORS) THROUGH THE DOOR IAMB INTO OTH OR NON ABSORBENT SURFACE CAST IN PLACE OR PRECAST THE MASONRY WALL W/ 3/16" DIA. TAPCONS 7.10.2 LATH TO WOOD FRAMING SOLID SMO - ( - - CONCRETE) L.E. FOOTING, IS PREPARED AS INDICATED IN ASTM C926 PENETRATING l 1/2" MIN. INTO THE MASONRY WALL MASONRY WINDOW/DOOR BUCK 7.10.2.1 LATH TO WOOD 7 INCH O.C. MAXIMUM (TOO TIGHT OF SPACING WILL EFFECT - TIN 5.2.2. THIS AREA OF THE FOOTING MUST BE PREPARED IN ORDER TO SECTION PROVIDE. THE PROPER. REQUIRED SUCTION. SOLD CMU SURFACES 1. DUPONT TYVEK FLUID (BRUSH FORMULATION) SHALL BE APPLIED ATTACHMENT ' srucc1 ENCAPSULATION)2DIA 7.10.2.2 DIAMOND -MESH EXPANDED LATH, FLAT -RIB EXPANDED LATH, WIRE LATH, PRIOR BELOW GRADE (SUCH AS STEM WALL) MUST BE THOROUGHLY CLEANED/PREPARED R I TO THE MASONRY OPENING &THE BACK OF EACH BUCK PRIOR TO SCALE. , N.T.S. R N NAILS VERTICAL FRAMING MEMBERS Bd HORIZONTAL FRAMING MEMBERS 1. /� INCH ROOFING TO STUCCO ANDINTEON. ACCESSORY END JOINTS AND INTERSECTIONS MUST BE EMBEDDED IN SEALANT INSTALLATION. DO NOT APPLY FLUID TO EXTERIOR AREA TO HAVE FILL ALL CORNERS W FLASHING OR DUPONT SEALANT STUCCO. CO / NOTE: DOORS &WINDOWS SHALL 8E INSTALLED PER MANUFACTURERS COMMON NAILS, 1 INCH ROOFING NAILS -PENETRATION /aINCH,'1 INCH ROOFING -'/.INCH '/.INCH (CAULKING) ' FOR TYVEK FLUID APPLIED SYSTEM.. SPECIFICATIONS TO WITHSTAND THE MINIMUM DESIGN PRESSURES REQUIRED AS Q NAILS CROWN -ENGAGE MIN: 3STRANDS -PENETRATE MEMBER 7.10.2:3 EXPANDED 3/8 INCH RIB LATH LATH MUST NOT BURN THE ACCESSORIES -CUT SHORT FOR EMBEDMENT/LATH 2: :WINDOW BUCKS ARE TO BE 2X4 OR 2X6, #2 S.Y. PINE, PRESSURE TO 2.5CCA. BUCKS ARE TO BE FULLY BONDED TO NOTED IN THESE PLANS). HORIZONTAL AND VERTICAL FRAMING MEMBERS NAILS OR STAPLES COVERAGE TREATED MASONRY WITH SIKA IA CONSTRUCTION ADHESIVE. FOR DOUBLE ;HORIZONTAL -1-3/4 INCH PENETRATION 2 INCH LONG NAILS OR STAPLES DO NOT CAULK CONTROL JOINTS - VERTICAL CONTROL JOINT MUST BE CONTINUOUS THROUGH HORIZONTAL CONTROL BUCK INSTALLATION, BUCKS ARE TO BE FULLY BONDED TO EACH VERTICAL - 3141NCH PENETRATION = 1 INCH NAILS OR STAPLES OTHER. 7.10.2.4 COMMON NAILS -BENT OVER ENGAGE MIN. 3 STRANDS OR BENT OVER RIB ' JOINT BACKER ROD REQUIRED NOT JUST CAULKING Q 3. FASTENERS ARE To BE1/4"0 TAPCONS WITH MINIMUM 7.10.2.5 SCREWS: HORIZONTAL AND VERTICAL -5/8 INCH PENETRATION -ENGAGE. MIN. PENETRATION OF 1 3/4" INTO MASONRY. USE STAGGERED SPACING 3 STRANDS (EQUALS 1 INCH LONG SCREWS) 3/8 INCH RIB LATH - SCREW PASS M C926 AST.6 OF TAPCONS EQUAL TO, OR LESS THAN REQUIRED FASTENERS THROUGH RIB BUT NOT DEFORM RIB 4 WATER -MUST BE POTABLE, SUITABLE FOR DOMESTIC CONSUMPTION SPECIFIED BY MANUFACTURER FOR FRAME TO BUCK INSTALLATION. 5.2 SOLID BASES. REMOVE FORM TIES. OR OTHER OBSTRUCTIONS- TRIMMED BACK 4. BUCKS TO BE FASTENED HORIZONTALLY AND VERTICALLY TO 7.10,3 LATH TO METAL FRAMING 5 2 .1 SOLID SURFACES SHALL HAVE SUCTION(ABILITY TO ABSORB WATER ) CONCRETE BEAMS AND COLUMNS OR GROUTED MASONRY; 7.10.3.1 18 GAUGE WIRE TIES, CUPS OR OTHER CARRYING STRENGTH, CORROSION 5.2.2 SMOOTH OR NON -ABSORBENT SURFACES (SUCH AS CAST -IN -PLACE OR PRECAST CONTRACTOR TO COORDINATE OPENING DIMENSIONS. RESISTANT' FRAMING MEMBER -ENGAGE MIN. 3 STRANDS 7.10.3.3 SCREWS. 3/8 INCH THROUGH F CONCRETE) SHALL BE PREPARED TO RECEIVE STUCCO BY ONE OF THE FOLLOWING „' WHERE Y4 P.T. SHIM IS USED; WINDOW FRAME SHALL BE SECURED TO 3/8 INCH RIB LATH -THROUGH RIB DO NOT DEFORM RIB METHODS: 5.2.21 SANDBLASTING, WRE BRUSHING, ACID' CONRCETE OR MASONRY WITH I/4"O TAPCONS OF SUFFICIENT LENGTH 7.10.5 LATH TO SOLID BASE -CONCRETE -MASONRY 5.2.2.2 DASH COAT TO ALLOW FOR 13/4" EMBEDMENT AT SPACING SPECIFIED BY N.O.A. POWER OR POWDER ACTUATED, COMBO POWER ACTUATED AND HARDENED 3 BONDING COMPOUND AGENT 5.2.2, / CONCRETE STUB NAILS DOOR BUCK INSTALLATION SAME AS WINDOW WITHOUT SILL. COMBO -ONE POWER OR POWDER ACTUATED AT EACH CORNER AND ONE AT 5.2.3 LATH- -PER C1063 MASONRY BLOCK WALL MID -POINT OF THE LONG DIMENSION, BALANCE CAN BE HARDENED CONCRETE STUB NAILS 7.1.4 SEPARATION SHALL BE PROVIDED WHERE STUCCO ABUTS DISSIMILAR MATERIALS ROWS 16 INCH MAXIMUM O.C. -7 INCH MAXIMUM D.C. SPACING, CORROSION OR OPENINGS 7110 STUCCO COATS THAT BECOME DRY SHALL BE EVENLY DAMPENED RESISTANT 3/4 INCH LONG MINIMUM 3/8 INCH HEADS 3/8 7NlCK SCRATCH COA T STUCCO TO LATH 7.9 SPACING OF ATTACHMENT OF LATH 7.2 THREE COAT -7/8 INCH TOTAL THICKNESS -3/8 + 3/8 + 1/8 9/8 7NffCK FINISH COAT ATTACH AT 7 INCH MAXIMUM O.C. -DIAMOND MESH, FLAT RIB (TIGHT OF SPACING 7.2.1 FIRST (SCRATCH) COAT 3/8 INCH THICK MUST EMBED LATH, SCORE SURFACE L EFFECT STUCCO ENCAPSULATION) W/ 3/8 INCH RIB LATH AT EACH RIB LAPS PROPER TOOL FOR BOTH APPLYING STUCCO AND SCRATCHING WILL 7.2.1.1 FIRST (SCRATCH) COAT BECOMES FIRM -SCORE SURFACE HORIZONTALLY LAPPING LATH 7.2.1.2 FIRST COAT SUFFICIENTLY RIGID (FINGER PRINT) 7.8.1 SIDE LAPS -SECURED TO FRAMING MEMBERS -TIED BETWEEN SUPPORTS W/ 7.2.2 SECOND (BROWN) COAT 3/8 INCH THICK 0.0475 WIRE AT 9 INCH D.C. 7.2.2.1 SECOND (BROWN) COAT -BROUGHT TRUE ROD OR STRAIGHTEDGE 7.8.2 METAL LATH SIDE LAPS -�1h INCH (NOT MAX OR MIN, TOO MUCH LAP EFFECTS 7.2.3 THIRD (FINISH) COAT 1/8 INCH THICK STUCCO ENCAPSULATION) OR NEST THE EDGE RIBS STUCCO TO SOLID BASES METAL LATH -END LAPS 1 INCH 7.3.1 HIGH SUCTION BASES: EVENLY DAMPENED END LAPS BETWEEN FRAMING MEMBERS LACED OR WIRE TIED 0.0475 INCH 7.3.2 THREE COAT-5/8 INCH TOTAL THICKNESS -Y + 9 + 1/8 GALVANIZED, ANNEALED STEEL WIRE 7.3.2.1 FIRST (SCRATCH) COAT', INCH: BECOMES FIRM SCORE HORIZONTALLY WIRE LATH -LAPPED ONE MESH AT SIDES AND ENDS 7.3.2.2 SECOND (BROWN) COAT X INCtt EVEN PLANE ROD OR STRAIGHTEDGE 7.8.3 PAPERBACK LATH -VERTICAL AND HORIZONTAL LAPS BACKING TO BACKING AND 7.3.2.3 THIRD (FINISH) COAT 1/8 INCH METAL TO METAL 7.3.3 TWO COAT - % INCH TOTAL THICKNESS -3/8 + 1/8 7.8.3.1 BACKING LAPPED MIN. 2 INCH. BACKING SHALL NOT BE PLACED BETWEEN STUCCO ON MASONRY PLASTER BASE (LATH) AND FLANGES OF ACCESSORIES, METAL LATH TO METAL FLANGE C926 A1.6.1 MORTAR JOINTS SHALL BE FLUSH NOT STRUCK. DISSIMILAR MATERIALS SUCH CONTACT REQUIRED AS TIES, REINFORCING STEEL AND SO FORTH CUT BACK 1/8 INCH BELOW SURFACE AND TREATED WITH CORROSION -RESISTANT COATING DEVIL 2 COATS SCALE: N.T.S. APPUCAnON A2.1.6 MAX. DEFLECTION VERTICAL AND HORIZONTAL FRAMING L/360 7.10.1.1 SPACING FRAMING MEMBERS -TYPICAL A2.2.3 VERTICAL AND HORIZONTAL SURFACES MEET BOTH SURFACES SHALL LATHWALLS 24 INCH O.C. CEILINGS INCH O.C. TERMINATE WITH CASING BEADS FLAT RIB -WALLS 16 INCH O.C. CEILINGS 16 INCH O.C. VERTICAL SURFACE EXTEND MIN. X INCH BELOW HORIZONTAL - FORM DRIP EDGE 3/8 INCH RIB LATH -WALLS 24 INCH O.C. CEILINGS 24 INCH O.C. HORIZONTAL CASING BEAD TERMINATE MIN. 14 INCH FROM BACK OF VERTICAL 7 INCH O.C. FRAMING MEMBER, 3/8 INCH RIB LATH AT THE RIB SURFACE 7.10.1.2 LATH LONG DIMENSION PERPENDICULAR TO SUPPORTS 7.10.1.3 LATH ENDS SHALL BE STAGGERED 7.10.1.4 LATH SHALL NOT BE CONTINUOUS THROUGH CONTROL JOINTS BUT SHALL BE STOPPED AND TIED AT EACH SIDE t, 7.10.1.5 CEILINGS -CASING BEADS REQUIRED AT COLUMNS, WALLS BEAMS OTHER ELEMENTS, MIN 3/8 INCH CLEARANCE BETWEEN ELEMENTS 7.10.1.6 WALLS -LOAD BEARING OR PARTITIONS -CASING BEADS REQUIRED -BUTTING r INTO STRUCTURAL WALLS,COLUMNS, FLOOR OR ROOF SLABS, SIDES OR ENDS OF WALL' OR PARnnON, LATH SHALL TERMINATE AT INTERNAL ANGLES. 3/8 INCH CLEARANCE REQUIRED BF16-18-2T TYP. PILASTER SHALL HAVE #5 8F16-1B-2T TYP. SF16-1B-2T iYP. LATH INSTALLED SMOOTH GOING DOWN AND ROUGH COMING UP -STUCCO HOOK BAR INTO PRECAST APPUED WITH FORCE AND PRESSURE GOING UP Y LATH OVER METAL STRAPS AND OVER PEEL AND STICK LINTEL ^'' �. .c . 77. ACCESSORIES TYPICAL COLUMNS f c 7.11.1 METAL ACCESSORIES COMPLETELY EMBEDDED IN STUCCO SHALL HAVE :' METAL ROOF ON PEEL-N-STICK ON 5/8' COX PLYWOOD 2" X 4" PRE-ENGINEERED WOOD. TRUSSES ON. 24" CENTERS 5:12 TYPICAL ROOF PITCH R-20 SPRAY FOAM INSULATION IN ATTI HURRICANE STRAP@ EACH TRUSS.'"\\ METAL DRIP STRIP \ 1X6 HARDI-FASCIA ON 2X4 SUB FASCIA STUCCO W/ CONTINUOUS 12" / 5/8 CEILING VENTED SOFFIT SEE DETAIL BOARD DOUBLE BOND BEAM W/ #5 BAR IN EACH ��DO PRE -CAST LINTELS ABOVE NS 6, WINOO PRECAST SILL STUCCO 1/2' DRYWALL ON FURRING STRIPS ON R4.1 TRI-FOIL EXTERIOR INSULATION 4" CONCRETE SLAB W/6X6 10/10 WWM ON 6 MIL. VAPOR BARRIER ON WELL 1 COMPACTED, TREATED FILL w 1 #5 ROD W 40" HOOK MIN. IMBED M OF fi" INTO FOOTER. SEE STRUCTURAL ENGINEERING LAYOUT '..� FOR LOCATION AND SPACING. G 20" W X 16" D FOOTING W/2#5 REBAR CONT. W/ MIN. 3" COVER (SEE SHEET 2) 4' " 0 TYPICAL WALL SECTION SCALE 1/2" = V 0" 7.11.1.1 FLANGES SECURED MAX. 7 INCH O.C. CEILING — (2) #5 HOOK BARS PILASTER SHALL HAVE #5 z1t3 CASING BEADS ISOLATE NON- BEARING MEMBERS FROM LOAD BEARING MEMBERS BOARD DOUBLE 2X4 TOP INTO PRECAST LINTEL HOOK BAR INTO PRECAST ALL PENETRATING ELEMENTS SEPARATE DISSIMILAR MATERIALS PLATE NAILED TO BOTHWAYS LINTEL 7.11.4 CONTROL JOINTS 2-2X12 #2 TRUSSES 1-16d 25„ MIN. 25 MIN. 25„ MIN. SINGLE PREFABRICATED PRODUCT OR TWO PIECE EXPANSION JOINT PROPERLY CEILING SINGLE 2X4 TOP SYP HEADER NAIL PER TRUSS BAR LAP BAR LAP BAR LAP INSTALLED BACK TO BACK CASING BEADS W/ FLEXIBLE BARRIER MEMBRANE BEHIND BOARD PLATE NAILED TO TRUSSES OVER DOOR ` 1-16d NAIL PER 1/2^ DRYWALL 1/2' DRYWALL J�_ �L REVIEWED FO: TRUSS MIN. TYPICAL COLUMNS SHALL BE 8" X� EXTERIOR MASONRY BLOCK EXTERIOR MASONRY BLOCK i/2' DRYWALL WALL W/ (1) #5 BAR VERTICAL WALL W/ (1) #:i BAR CODE CQMPLIAI` ON EACH SIDE OF WALLS 2X4 STUD 16" PILASTER FILLED W/ 3000 PSI IN EACH FILLED CELL VERTICAL IN FILLED CELL ST. �„4„IGIE COUR' WALL @ 16°� CONCRETE & (4) #5 BARS D.C. W/BOCC 2X4 STUD WALL 16' O.C. NONBEARING FRAMED SPH4 @ 4' D.C. TOP & BOTTOM TYPICAL COLUMNS SHALL HAVE (4) 5 DOWELS (1) #5 DOWELS (1) #5 DOWELS WALL R11 INSULATION SINGLE 2X4 PT SINGLE 2X4 PT BOTTOM PLATE W/ BOTTOM PLATE 8d CASE HARDENED CONCRETE W/ 8d CASE NAILS a IS' O.C. SLAB HARDENED 1/2' J-BOLT OR NAILS @ 18" ANCHOR BOLTS O.C. 18 24' O.C. W/ - — — 3' WASHERS 2X4 NON -BEARING- DNCRETE e•..:, SLAB SCALE: 1/4" = V-O" ° .. Al 2X4 GARAGE E WALL SECTION SCALE: 1/4" = 1, 0" ail SIONS ,"R ST. LUCIE COUNTY DSP 4-9-21 # T_ 25" 25" MIN. (3) 5 REBARS BAR LAP BAR LAP SLAB REINFORCEMENT C NTINUOUS PER SPECS, FINISHED FLOOR 7L CLEAN COMPACTED TERMITE TREATED FI LL PORCH DETAIL A -A SCALE: N.T.S. - "'T". . . . . IWVAPOR BARRIER COMPACTED FILL PER SPECS. PER SPECS. PORCH DETAIL B-B SCALE: N.T.S. 25" BAR LAP VERIFY FOOTING SIZE L ON FOUNDATION PLAN , SLAB REINFORCEMENT PER SPECS. �— CONCRETE SLAB PER SPECS. FINISHED FLOOR 771 VAPOR BARRIER- fte 0 aPER 4WPERSPECS. SPECS.Fl PACTED FILL * ON FOUNDATION PLAN S '.10, PORCH DFTAII r---r TO THI? BEST OF MY KNOWLEDGE, THIS STRUCTURE COMPLIES AND HAS BEEN DESIGNED IN ACCORDANCE WITH SECTION 1609 OF THE 7th EDITION FL. BLDG, CODE SCALE: N.T.S. R r I co 1 �y E,V C\2 O E—I O 00 W Z`- Q d' H u r-� EW- H-1 LO t Ci2 02 co ;nz: W Q EE O O � W cr) CA Z 0 W4 CO z -pq I W 01 GL., C? Lo ' D E� `O CO P4 U Z Q' r� CD ENg yy 42 7E 0 OIIf7FR TODD N. SMITH, P.E., FL. PE #42082 r " I I. STRAP AND TIEDOWN SCHEDULE UPLIFT FORCES SUPPLIED BY THER MANUFACTURER OF THE PRE-ENGINEERED TRUSSES. FINAL TRUSS ENGINEERING UPLIFTS VARY FROM THIS SHEET., CONTRACTOR SHALL VERIFY ALL BEARING FOOTER LOCATIONS WITH FINAL TRUSS ENGINEERING LAYOUT. F FASTENERS EQ AT A SPECIFIC BEARING LOCATION. 2X) DENOTES NUMBER ORE REQUIRED Q :. TRUSS INFORMATION FROM MANUFACTURER TRUSS CONNECTION TRUSS INFORMATION FROM MANUFACTURER TRUSS CONNECTION TRUSS - IDENTIFICATION BEARING JOINT UPLIFT REQUIRED TRUSS TO MASONRY BOND BEAM OR WOOD TRUSS IDENTIFICATION. BEARING JOINT UPLIFT REQUIRED TRUSS TO MASONRY BOND BEAM OR WOOD AO1G 11 2 1533/1108 HETA16,THD26-2 G04 3 6 499/504 META16- A02 2 12 720/631 META16-,HUS26 H01 2 6 8 152 152:201 / / META16- ,A03 2 11 720/631 META16-,HUS26 H02 2 4- 420420 / META16- - A04 1 8 620/633 : .'META16-,HUS26 H03 4 2'.1 313/429.: META16- A05 1 - 9 620/630 HUS26,META16- M20 1,9,16,11,15,17,13,10 WORST CASE 157 VTCR 'A06 1 B 620/630 HUS26,META16- MG01 1 4 419/775 META16-/HUS26 A07 1 10 620/630 '. HUS26,META16- MG02 4 1 710/1203 META16-/HUS26 A08 11 1: 634/616 HUS26,META16- MV2 1 2.. 24132. VTCR A09 : 30 1 640/611 HUS26,META16- MV4 3 2. 80/47.. VTCR A10 1 9 608/646 HUS26,META16- MV5 5 3. 4 24/21/172 VTCR All 1 9 597/636 META16- MV6 S 3 4 20/14/174 VTCR Al2 1 : 9 597/636 META16- MV8 5. 4 77/228 VTCR. `A13 1 9 597/636 .META16- MVSO 7 5 6 >100/214/168 VTCR' A14 1 9 597/636 META16- V3 1 3 49/49 VTCR AfS 1 8 599/638 META16',HUS26 V5A 5 3 4 34 /62 77 / VTCR. A16 2 9. 699/636 META16-,HUS26 V7 5 3 4. 86/94/110 VTCR A17 1 8 589/628 META16-,HUS26 V9 7: 6 5 >100/106/224 VTCR. A18 1 9 589/628. HUS26' VLO 1.'. 3 4 85/85/166 VTCR A19 1 8 589/628 HUS26 V14 1 3 4 127/127/244 VTCR. A20 1 8 589/628 HUS26 V18 1,7,12,10,13,8 WORST CASE 216 VTCR 'A21 : 1.. 9 - 589/628` HUS26 ZCJl - 3 2 4 2/185/20 META16-/LSS0T&B A22 14 8 605/605 HUS26. ZCJ3 3. 2 54/164 META16-/1_S50T&B `A23 14 8 i605/605. .HUS26 ZC33A 1 2 3 42/65/9. META16-/LS50T&B A24G 18 S0 f 1522/ 608 ' THD210 ZCJS 3 2 4 110.184 1 / / META16-/LS50 T&B B01G 13 2 6357/5775 (2)VGT ZC15B :. 1 2 3 . 72/117/8 - META16-/LS50 T&B B02. if 2 769/846 META16 ZE35 3 2 4.. 112/185/1 -. META16-/LS50 T&B B03 -. 11 2 764/851 META16 ZE35A 6 2 137/174 META16-/LS50 T&B 804G 12 2 1561 1148 / HETA16 ZEJ 6 3 2 4 134 195 2 / / METAl6-LS50T&B -COl 7 2 511 614 / METAl6- HUS26 ZE77 3 2 4 167 231 1 / / META16- LS50 T&B CO2G 8 1 2 1 1189/1292 .META16-,HUS26 ZEJ22 3 2 30/161 META16-/LS50.T&B ' D01G 1 8 2.. 4239,3765 (2)VGT ZE)56. 3 2 4 1 125/191/2 META16-/LS50 T&B EO1G 7 2 -:.876/981 METAI6,HUS26. ZEJ65 3 2 4' 151/203/1 META16-/LS50 T&B FO1G 11. 6 2027/2264 (2)VGT ZH35 4 2 5 73/282/70 META16-/LS50 T,LTHJA26 BOT. F02G 9 5 2760/1908 '(2)VGT ZHJ7 4 2 5. 128/357/162 META16-/LS50,T,LTHJA26 BOT. GO1G 4/ 7 615 581 METAl6. ZHJ2L 3 2 39J235 META1 - LS50 T LTHJA2 BOT. 6/ 6 G02 6, 3 471/532. META16- ZH356 4 2 5 180/304/113 META16-/LS50 T,LTHIA26 BOT. G03 7 4 487/516 META16- ZHJ65 4 2 5 -... 132/336/145:. META16-/LS50 T,LTHJA26 BOT. i A MAXIMUM OF A 1-1/2" FILLER MAY BE USED BETWEEN THE PRE-ENGINEERED STRAP AND THE TRUSS WITH TRUSSES COMMON NAILS IF THE DISTANCE BETWEEN THE STRAP & TRUSS IS GREATER THAN 1/2" OR LESS THAN 1-1/2". THIS ELIMINATES THE SLACK IN THE STRAP TO TRUSS CONNECTION. ROOF SHEATHING REPLACEMENT TRUSS ANCHOR II I.� I.I USE A SIMPSON MTSM20 STRAP WHEN THE EMBEDDED STRAP IS MISSED OR FURTHER THAN 1-1/2" FROM THE TRUSS. USE (4) 1/4" X 2 1/4" (SIMPSON) TITEN ORTAPCON SCREWS (MASONRY WALL) & (8) 10d X,1 1/2" NAILS (TRUSS) FOR UP TO 1045 LBS OF UPLIFT. FOR HIGHER UPLIFT CONNECTIONS CONSULT THE ENGINEER. MISSED STRAP CONNECTION SCALE: N.T.S. TOP CORD OF TRUSS SIMPSON' CR' FASTENER @ EACH TRUSS INTERSECTION IF ROOF SHEATHING IS NOT INSTALLED UNDER VALLEY FRAMING, THE TOP CORDS OF THE TRUSSES SHALL BE BRACED: W/ 2"x4" PURLINS @ T O.C. FASTEN 2x4'S TO THE BOTTOM SIDE OF THE TOP CORDS W/ 2-16d NAILS @ EACH TRUSS. (ONLY REQUIRED UNDER VALLEY FRAMING) VALLEY TRUSS FASTENING DETAIL 1/2" ]-BOLTS OR: HILTI KBII 12-512 KWIKBOLTS U S ANCHOR W1254 BAWL -STUD 7424. W/2" DIA.'X 1/8" ASPHALT SHINGLE ROOFING NASHERS OVER PEEL-N-STICK ON 5/8" COX PLYWOOD 10d RINGSHANK NAILS @ 4" D.C. METAL DRIP EDGE OF GARAGE ALUMINUM FASCIA 2"x4" LADDER @24" 2"X6" P.T. ON ROUGH D.C. ATTACHED @ .OPENING (4) 1/2" BOLTS ENDS WITH (2) 11 _x REQUIRED REFER TO L .BOTH 16d NAILS EACH END GARAGE DOOR MANUFACTURER FOR BOLT ' SPACING CONT. 2"x4" SYP OR BETTER 12' O.H. VINYL SOFFIT CONT. 2"x4" SYP OR ATTACHED W/ (1) 11 BETTER W/ 16d NAILS #5 REBAR AT TOP MIN.. (1) REQUIRED ..; .i: A_�1 1/2" COVER 2"x4" P.T. NAILER FASTENED TO BOND LEVEL RETURNS •: : BEAM W 3/16"x2-3/4" TAPCONS OR " CMU HILTI 2-7/8" X-ZF NAILS.0 24" O.C. i :. ;: DESIGN PRESSURE IN ,.. +37.8 P.S.F. OF SOFFITS..... .. .. ._ . ,� ..... .. .•: x4 #2 SYP LEVEL ..1...:. .::..i 2 I - 50.3. WITHIN 3.33 OF �- �����•���- g � •'••' �.` RETURNS @.24" D.C.; : NAIL CORNERS I :. '.1 0 GROUT i,.. ., .. LEDGER W/ (2) lOd . - TOENAILS I DESIGN PRESSURE IN „L ., : S_ . ° OF LINTEL CAVITY ' I +3T.8 P.S.F:OF.REMAINING 41 I LINTEL (VARIES) .O $". N ( S) I. B SOFFITSNOMINAL L.' ...,.::.`. ....: .... .....: ........:,,.'. ,.,J. -I ... ....J. .I cz . 11 11 .. .� .-. .�.......�.... .._ :. 170 MPH EXP. C 1 , . L LINTELS SHALL HAVE A �� 1 ' IL\g 1 C MINIMUM 4 BEARING' ON EACH END I I FASTENS/8" RIBBED I T L 1 LATHE TO FRAMING W/ 1 t F=FILLED WITH GROUT RF = RECESSED INSTALL 2"x4" BLOCKING BETWEEN MIN. 16 GAUGE 2" LEVEL RETURNS SO THAT THERE. - STAPLE @EACH RIB & FILLED W/GROUT ARE NO OPEN. SPANS > 10" V (q,rf) AT ALL BEARING .......... ..... .. QUANITY OF #5 REBAR AT UNVENTED STUCCO SOFFIT INSTALLED �. POINTS. :BOTTOM OF LINTEL CAVITY ON RIBBED LATHE FASTEN TO FRAMING BOTTOM VIEW Q VANITY OF #5 CUT VIEW STUCCO SOFFIT DETAIL - NOMINAL HT. REBAR AT TOP OF. NOMINAL WIDTH LINTEL DOOR AND WINDOW ATTACHMENT SPECIFICATIONS LINTEL INFORMATION MASONRY (ALL MASONRY ROUGH OPENINGS SHALL COMPLY W/ FBCR 606.5.1.1) NOTE: WINDOWS -.THE 2" X 4" P.T. WINDOW BUCKS SHALL BE ATTACHED TO THE MASONRY WALL WITH 1. ALL LINTELS SHALL BE 8F16-lB/lT UNLESS 3/16" DIA. X 3 3/4" TAPCONS AT 12" D.C. ON THE SIDES AND ON THE TOP OF THE OPENING. THE WINDOWS OTHERWISE NOTED SHALL BE ATTACHED TO. THE BUCKS WITH #1OX 1-5/8" FLAT HEAD SHEET METAL SCREWS IN EACH PRE - ,MANUFACTURED HOLE. DOUBLE WINDOWS SHALL BE INSTALLED WITH STEEL REINFORCED JOINING MULLIONS. BUCK ATTACHMENT OPTION (WINDOWS)1X BUCKS MAYBE USED ONLY. W/ 3/16" DIA: TAPCONS @ EACH PRE -MANUFACTURED HOLE PENETRATING INTO THE MASONRY WALL 1 1/2" MIN. DOORS -THE 2X DOOR BUCKS SHALL BE ATTACHED TO THE MASONRY WALL WITH 1/2" SPECIFIED ANCHORS@ 24" O.C. OR W/3/16"TAPCON ANCHORS @.16" D.C. THE DOOR JAMBS SHALL BE ATTACHED TO THE BUCKS W/2-#10 WOOD jUuUu <SCREWS 16" O.C. PER SIDE. ALL SLIDING GLASS DOORS SHALLPRE-MANUFACTURED HOLES FILL D @ VE ALL E WITH.#10 SCREWS ATTACHING THE FRAME TO THE ROUGH OPENING. o K ATTACHMENT OPTION DOOR 1X BUCKS MAY BE USED ONLY PENETRATING ' BUCK (DOORS) W/.3/16" CIA. TAPCONS @ 16" O.C. PENETRA NG o FILING BOARD Y WALL 1 2" N. C THROUGH THE DOOR L 1/ MI FLASHING REQUIREMENTS ALL NEW EXTERIOR OPENINGS SHALL C WITH.FBCR 703.4 SEE DETAIL 0 Q LL BE IN ACCORDANCE ( ) d SINGLE 2' x4 TOP NOTE:IF THE MANUFACTURER OF THE DOORS AND/OR WINDOWS HAVE M ' NOT I ORE RIGID SPECIFICATIONS, PLATE NAILED TO USE THEIR ATTACHMENT PROCEDURES IN LIEU OF THE ABOVE TRUSSES (1) 16d ALL FASTENERS SHALL BE 6 FROM THE ENDS AND CORNERS. NAIL PER TRUSS ALL TAPCONS SHALL HAVE A MINIMUM EMBEDMENT OF 1 1/2 INTO MASONRY WALLS. O ** IF THE MASONRY OPENING IS TOO WIDE OR HIGH TO INSTALL THE BUCKS AS DESCRIBED ABOVE, 1/2" DRYWALL .ON THE CONTRACTOR SHALL CONTACT ENGINEER FOR ALTERNATIVE BUCK & FLASHING INSTALLATION REQUIREMENTS. EACH SIDE OF WALLS WALL SUPPORT O 2"x4" STUD WALL D @ 16" O.C. _ o 1-1/4 ALUM ROOFING @ 6" O.C. NAILS @ SEAMS WALL SHEATHING W/ 8d O NON -LOAD ATTACH SHEATHING @ 4'O.C. NAILS @ 4" O.C. IN THE FIELD BEARING FRAMED FIRST 3 TRUSSES a WOOD WALL " DDERED'° SOFFIT DETAIL N WEB INSTALL 2"x4" BLOCKING BETWEEN TOP CORDS TO ACCEPT'X' BRACE A34 Lz 1 SET OF 2"x4" 'X' BRACE 11 RATRUNNERS @ X CENTER & 8" O.C.. EXTEND B O S T O HIP B R AC BACK 4 TRUSSES PAST HIP GIRDER I;c A SAMPLE / LEFTOVER TUBE OR CONTAINER SHALL BE LEFT ON SITE FOR VERIFICATION FOR. INSPECTION PURPOSES. INTERIOR SIDE OF MASONRY WALL DUPONT TYVEK FLUID BETWEEN BLOCK & PT BUCK ONLY WINDOW OR DOOR ATTACHED TO BUCK PER MANUFACTURER'S REQUIREMENTS DUPONT TYVEK FLUID SHALL NOT BE APPLIED EXTERIOR STUCCO @.STUCCO AREAS SIDE OF MANSONRY WALL FLIUD AREA ON OPENING BUCK DETAIL r SCALE: 2" = V--O° OPTIONAL PRODUCTS THAT COMPLY WITH. AAMA 714-12 OR 714-15: DUPONT TYVEK FLUID APPLIED WB+ (AAMA 714-15). OSI QUAD FLASH LIQUID APPLIED FLASHING MEMBRANE (AAMA 714-12). FORTIFIBER BUILDING SYSTEMS MOISTOP SEALANT & LIQUID FLASHING (AAMA ' 714-15)...PROTECTO WRAP LWM200 (AAMA 714-15). PROSOCO R-GUARD FAST FLASH (AAMA 714-12). BASF MAXFLASH LIQUID FLASHING MEMBRANE (AAMA 714-15). MASTER WALL INC. SUPERIORFLASH (AAMA 714-12). TREMCO TREMSEAL PRO (AAMA 714-15). REVISIONS 1. PER ST. LUCIE COUNTY DSP 4=9-21 vu N.T.S. LA - . ':. • :.a. .. ;.a ' ,. w:,. :...: SINGLE 2"x4" PT 1' SCALE: 2" = .�: .BOTTOM PLATE W/ OVERHEAD GARAGE DOOR BUCK BdNAILS @ 18Eo C GABLE ENDITRUSS BRACING CHART TRUSS HEIGHT BRACING STUD : 2"x6" HEADER 1-BRACE I NOT 0 TO 4'1" ..REQUIRED TYPICAL 2"x4" L-BRACE NAILED TO2"x4" VERTICALS L-BRACE REQUIRED 47' TO 7'8" W/ 16d NAILS 8" O.C. VERTICAL STUD ON TRUSS L-BRACE L-BRACE GABLE HEADER SPACING WITH 78" TO 14' - HEADER 2"x4" DIAGONAL 1 HEADER PLACED AT CENTER OF TRUSS HEIGHT BRACE TOE -NAILED L-BRACE W/ 4-#16 TO HEADER 2 HEADERS PLACED AT 1/3 AND 2/3 OF TRUSS WITH'2 14' TO 20' HEADERS HEIGHT ,CONNECTION ON MASONRY DETAIL CONCRETE SLAB. 2X4 NON -BEARING SCALE: 1/4" = l'-O" PRODUCT APPROVAL SUBMITTAL AFFIDAVIT PRODUCT BUILDING PRODUCT GLASS OPENING ID MANUFACTURER MODEL # DESIGN DESIGN APPROVAL D,_ cSCRIPTION PRESSURE PRESSURE PSF WINDOWS M.I. WINDOWS & 185 SH FL# 17499:1 IMPACT T55.0/ 55.0 +37.8/ 50.3 DOORS LLC SWING DOOR PLASTPRO SERIES N FIBERGLASS FL# 15213.5 IMPACT +50.0/-50.0 +36.0/-39.3 FRENCH DOOR PLASTPRO SERIES N FIBERGLASS FL# 17184.5 IMPACT +50.0/ -50.0 +36.0/ -47.2 SLIDING GLASS MI WINDOWS& SERIES 120/130/140 ALUMINUM SLIDING FL# 22401.3 IMPACT +55.0/-55.0 +32.1/-35.3 DOOR DOORS LLC GLASS DOOR GARAGE DOOR DBA DOORS MODEL# 824/811 FL# 17-1018.12 N/A +36.0/ -44.0 +26.4/ -29.4 RO F EXTREME METAL 5V CRIMP FL# 17022.01 R-9 NA -220 -115.2 COMPANY METHOD D ROOF]:NG INTERWRAP INC. TITANIUM PSU-30 FL #11602.1-Rll NA -142.5 NA UNDERLAYMENT BOSTON HIP JAMES HARDIE BUIDLING PRODUCTS HARDIE LAP SIDING FL# 13192.2 NA 135.0 11.5.2 r BASED ON 1NTERPILATION OF PRODUCT APPROVAL DATE FOR 14.5" SPAN ** GLAZING ON BOTH WINDOWS IN BATHROOMS SHALL BE TEMPERED GLASS PER. F.B.C. 308.4 WHERE HIP MEETS RIDGE BETWEEN TRUSSES INSTALL 2 X12RID E I t BOARD TO ACCEPT HIP CATS (2 X 12 MAY NEED TO BE CUT TO, MAT( H SLOPE). NAIL WITH 3-16d NAILS PER END I HIP CATS SHALL. BE. I 1 I CONTINUODUS TO RIDGE W/ I I I (2) 16d NAILS PER END HIP TRUSS (HT) I I I I HIP GIRDER I I TRUSS (HGT) TX NN,, I I n I N N / V) a' DETAIL TO. THE LEFT SIMULATES TRUSS PLAN CORRELATES TRUSS IDENTIFICATION TO CONNECTORS r HIP TRUSSES -NAIL HIP JACK TRUSSES. W/ TOP: .CHORD 2- #10 COMMON BOTTOM CHORD 2410 COMMON ~� SUB -FASCIA BOARD ROOF SHEATHING TO BE CARRIED OVER 2 SPANS MINIMUM @ ALL LOCATIONS NAIL END OF JACK TRUSSES W/ HIP JACK TRUSS (H]T) TOP CHORD'S- 16d COMMON BOTTOM CHORD 3-16d COMMON 16d NAIL HAS A MAXIMUM LATERAL RESISTANCE OF. JACK TRUSS CONNECTION @ 108lbs. HIP AND GIRDER TRUSSES TYVEK® HOMEWRAP® OVER WOOD m MASONRY BLOCK WALL INSTALL TYVEK®FLEXWRAP-OVER MOUNTING FLANGE. LAP TYVEK® & TAPE JOINTS. 3/8" THICK SCRATCH COAT MINIMALLY EXPANDING POLYURETANE FOA�1 1/8" THICK FINISH COAT APPROVE YS' CAULKING%& FQF_Q :: (AROUND OPENI�I6 MPLIAN OPENING WRAP D&AIL OvCpIET /� COUN L80CC FASTEN TYVEK®FLEXWRAP- CORNER USING MECHANICAL FASTENER TYVEKA STUCCO ON MASONRY DETAIL (2 COATS) AROUNDTALL PERIMETER®OFEOPENING ..SCALE: N.T.S. Ffie WINDOW SILL DETAIL TO TI LE BEST OF MY KNOWLEDGE, THIS STRUCTURE COMPLIES AND HAS BEEN DESIGNED IN ACCORDANCE WITH SECTION 1609 OF THE 7th EDITION FL. BLDG. CODE H <� E-H C(D G✓ H F-L-1 co�1 W 'eW �4 lnn-'I R� E-1 77'' 11 Q \J rY 0 E -•il FT-' Lei r� C0 GA L FS cr) o n C\2 C\2 L` Q 000 W E� Q ; CO C\2 CO (3) Z CO Z W W P4 to p U LCJ M i � �D E Q � E� Cl1 04 Z Z � E� co Q Q O .�- 4201 TE OF TODD N. SMITH, P.E., FL.. PE #'42032 ..a��i��lllllllllllllllllllllllllllllllllllllllllllllllllllllliiillllii111111111111111111111111111��!''''='''''!!Ills;lllllllllllllllllllll�����4'IIIIIIII�tllllllltllllll11111111111!i El HEPID HGT. 00 A ® hJ LJ I L-1 �Jlum N TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE COMPLIES AND HAS BEEN DESIGNED IN ACCORDANCE WITH SECTION 1609 OF THE 7th EDITION FL. BLDG. CODE CrD rn coo it � UwC E--� O a w � aa� � way c\2 Q E� � Wa W �1l+� U T c� C � co �w W L) co w� 1 z w :� w0 E� Z Z` O U) a � a la a� o .T OI�AAR 2 4 2°! TODD N. SMITH, P.E. FL. PE #42082 WARNING* ALL BEARING POINTS THIS IS A PLACEMENT PLAN FOR ENGINEERED BRACING: SEE FINAL ENGINEERING SHEETS FOR THE BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR COMPONENTS AS DEFINED BY WTCA 1 - 1995. 1) FOR THE ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS DESIGN DEPARTMENT APPROVES THEM IN ADVANCE MUST BE INSTALLED PRIOR TO DIAPHRAMS HAVE NOT BEEN ANALYZED BY INSTRUCTIONS ON THE BCSI-131 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. ALL HANGERS ARE SIMPSON STRONG -TIE OR USP INSTALLING ANY TRUSSES! FAILURE TO EAST COAST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE OUR DESIGN DEPARTMENT MUST APPROVE UNLESS OTHERWISE NOTED. INSTALL HANGERS O SO MAY RESULT IN DAMAGED TRUSSES AND WILL FOR ERECTION AND INSTALLATION OF TRUSSES RESPONSIBILITY OF OTHERS. ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ACCORDING TO THE CURRENT SIMPSON STRONG -TIE FOLLOW INSTRUCTIONS ON THE BCSI-131 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ADVANCE. OR USP CATALOG VOID ALL WARRANTIES. SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS rNGINEERING TRUSS DRAWINGS. Zb' 4" I Z' 4" 10 4-- 1 Z- O__ S 4-- M � LO r- n r r- r- rl- r` � LO M e- � N N N N N N N N N N N N N ZCJ 1 Nr ZCJ 1 ZCJ3 o ZCJ3 tQ (J M c o ti W W W W W W O O O O O O O ZCJ5 N N N N N N (7 ( Ur U' U' (D (D N N 1� ZCJ5 1ZCO2G o Nu ZCJ 1 0 _ @ /126 i On r On , n t On t On (On LO M a— 6 Q C01 No ZCJ3 U U U �J� 10 - o cov �� C7 N N N - = 1 y 11v ZEJ5 B04G b 3 0 o r L`Dn L(DD LfOD LLDD ZCJ1 B03 ZEJ5 w w _ W w N N io N N 0 ZCJ3 B02 N J5 > B01 G o v ZCJ5 ZEJ7 N N ZEJ7 ZEJ6 00 R ZEJ7 5 1(ZEJ6 ZEJ7 y7o-�'Oh' KZO. ZEJ6 n.OD OttOtt O' OD O„ O„ O' O,t O, On O' O t O t Ott OD O„L'O„ O' Ot, ZEJ7 ZEJ6 T e) ZEJ7 ZEJ6 ��1 D V ( = MG01 ' LLI ZEJ7 M 4 = _ ZCJ 1 ZEJ7 �_ F] 0 M 2 U N ZCJ3 ZEJ7 r' N ZCJ5 (U (M N O W 00 n tl O O O O (O LID d' M N O O (O LDXM N Ul ZEJ7 N N N ¢ ¢ N ¢ ¢ ¢ ¢ �— ¢ e— ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ O ¢ O ¢ O ¢ O ¢ O ¢ O¢ 7' 0" ¢ V ZEJ7 T 0" ZEJ7 MV ZEJ7 d ZEJ7 MV V ZEJ7 ZEJ7 MV 2 V ZEJ7 ZEJ7 MV M 4 V ZCJ5 ZEJ7 o N N V1 M V ZCJ3 F 2 N D01G N _ N _ !n y _ _ N _ ZCJ1 20 ZCJ5 IVAN ZCJ5 -- H03 ------- = - -- F01G (� ZC 1 0 1 LO ZCJ3 ZCJ3 C, CO H02 W N N N 1 N �y ZCJ1 00 ZCJ1 o N W W N W N N W W -� U c�2 H01 N N IN N N Y TC Dropped for x4 Outlookers f� lD M �y r M LD LO Ln lD lD LID LD LD .(�� U U U c) U L) ✓s 7' 8" N N N w w w w w w w N N N N N N N N N N 23' 4" 19, 0" 14' 0" 15' 8" 72' 0" 9'-4" Top of Brg Indicates Let End Pf Truss On Layout & Engineering Sheets ***All Flat Ceilings*** R ED TEFP.E. L PE #42082 ENGINEERED TIMBER TRUSS SYSTEMS PRODUCTS ECT EAST COAST TRUSS 5285 Sr. LUCIE BLVD. FT. PIERCE, EL 34946 OFFICE: (772) 466-2480 FAX: (772)466-5336 TOMER:Dave Golden Homes NAME: Comeau Re RESS:Slash Pine Trail 7COUNTY:Fort Pierce # J41250 MODEL:Model SQ FT 3377 ft2 DATE 02/12/21 LATEST=02/24/21 61G15S-31.003 (3) (c), EAST COAST TRUSS is the "Truss Design Engineer" Trussee are designed in acwrdance with the Florida Building Code NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his representitive acknowledges that this placement plan complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this drawing. The customer also acknowledges that he/she accepts financial responsibility for any repair, engineering, and labor required due to errors other than those of EAST COAST TRUSS. Signed: Date: CODE = FBC 2020/TP12014 ASCE 7-16 DESIGN CRITERIA =MWFRS OCCUPANCY CATEGORY= 11 EXPOSURE = C MWF SPEED =170 BUILDING TYPE =ENCLOSED MEAN HEIGHT: 15.00 ft FLOOR: DUR FACTOR=1.0 PS F=TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,5.0 ROOF: DUR FACTOR= 1.33 PS F=TCLL-TCDL-BCLL-BCDL 30.0115.010.0110.0 LOADS PER FBC & FRI "NON -CONCURRENT BC LL 10psf CONCURRENT BC STORAGE LL 20 psf DEFINITIONS MWF = MAIN WIND FORCE C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING TC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT # =POUNDS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. ALL GIRDER/COLUMN LOADS MUST BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. RECOMMENDED ON FLOOR TRUSSES SPANNING 20'-O" OR MORE UST BE SET WITH A SPREADER BAR. THE PREADER BAR SHOULD BE AT LEAST 1/2 0 A 1 I 1 1 1 I 7 I 1 1 1 1 Q Z LL In W CL G Q U) U) W J Z) U) III U) U) Z) W U) n O U ._.J IN LENGTH AS THE SPAN OF THE TRUSS Q NG SET. \ :ER TO BCI-B1 FOR COMPLETE O =CTION AND SAFETY PROCEDURES. 0 ALL BEAMS BY BUILDER n NOTE: TRUSSES DO NOT am SUPPORT ANY PLANT SHELVES -.,vo 1)2/24/2 1: Revised to Dutch hip over Garage & !r— Bdrm 1; Revised Roof pitch to 5/12 4- 2- Q 3- 4- 5- 6- TRUSS PLACEMENT PLAN if plotted 24x36) . Designed By: CO