TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Comeau Residence Builder Name: Dave Golden Homes
Street: TBD Slash Pince Trail Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL , 34951 Permit Number:
Y
U
Owner: Comeau Residence Jurisdiction: St. Lucie County
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
Narrow cavities
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pytpnri behind piping and wirong.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I between fire sprinkler cover nlates and walls or ceolanas,
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
J
FORM R405-2020
0
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
TBD Slash Pince Trail, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
2081.10 ft2
b. Frame - Wood, Adjacent
R=11.0
326.67 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0
2513.00 ft2
6. Conditioned floor area (ft2)
2513
b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows" Description
Area
12. Ducts, location &insulation level
R ft2
a. U-Factor: S I, U=0.31
g
183.50 ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 90
SHGC: SHGC=0.28
b. U-Factor: Sgl, U=0.33
82.00 ft2
SHGC: SHGC=0.26
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
41.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average Overhang Depth:
4.270 ft.
Area Weighted Average SHGC:
0.274
8. Skylights Description
Area
15. Hot water systems
Cap: 50 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.95
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 2513.00 ft2
Credits (Performance method)
CF, Pstat
b. N/A
R= ft2
c. N/A
R= ft2
I certify that this home has complie ith the Florida Energy Efficiency Code for Building
Construction through the above a er y saving features which will be installed (or exceeded)
in this home before final inspect 0therw se, i new EPL Display Card will be compl ted
based on installed Code comp'an feature .
Builder Signature: Date: ZZ 3 ZO
Address of New Home: r��� / City/FL Zip: e
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
fi
FORM R405-2020 „s i
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Comeau Residence
Builder Name: Dave Golden Homes
Street: TBD Slash Pince Trail
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner: Comeau Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
h. New construction or existing New (From Plans)
10. Wall Type42407.7 sgft.)
Insulation Area
:2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2081.10 ftz
b. Frame - Wood, Adjacent
R=11.0 326.67 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms 4
d. N/A
R= ft'
11. Ceiling Types (2513.0 soft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2513.00 ft
6. Conditioned floor area above grade (ftz) 2513
b. N/A
R= ftZ
Conditioned floor area below grade (ft2) 0
c. N/A
R= ftZ
7. Windows(265.5 soft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft'
6 90
a. U-Factor: Sgl, U=0.31 183.50 ftZ
SHGC: SHGC=0.28
b. U-Factor: Sgl, U=0.33 82.00 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.26
a. Central Unit
41.0 SEER:16.00
c. U-Factor: N/A ft'
SHGC:
Area Weighted Average Overhang Depth: 4.270 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.274
a. Electric Strip Heat
34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Gap: 50 gallons
9. Floor Types (2613.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2513.00 ftz
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft'
16. Credits
CF, Pstat
Glass/Floor Area: 0.106 Total Proposed Modified Loads: 74.03
PASS
Total Baseline Loads: 74.41
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
t �.
DATE: 2-18-2021
this building will be inspected for,
compliance with Section 553.908
- "
I hereby certify that this buildin a desig d, i compliance
Florida Statutes.,.
.
with the Florida Energy Code.i7
y'1�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
. .FORM R405-2020 I INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Comeau Residence
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2513
Lot #
Owner Name:
Comeau Residence
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Dave Golden Homes
Rotate Angle: 0
Street:
TBD Slash Pince Trail
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
-
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2513
23622.2
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
Toilet
25
235 No
0
1
Yes
Yes
Yes
2
M Bath
151
1419.4 No
1
1
Yes
Yes
Yes
3
Master Bedroom
256
2406.4 No
2
1
1
Yes
Yes
Yes
4
M WIC
104
977.6 No
1
1
Yes
Yes
Yes
5
Laundry
117
1099.8 No
1
1
Yes
Yes
Yes
6
Pantry
72
676.8 No
0
1
No
Yes
Yes
7
Hall
98
921.2 No
0
1
No
Yes
Yes
8
Kitchen
266
2500.4 Yes
2
1
No
Yes
Yes
9
Den
130
1222 No
2
1
Yes
Yes
Yes
10
Foyer
90
846 No
0
1
Yes
Yes
Yes
11
Bedroom 1
156
1466.4 No
2
1
1
Yes
Yes
Yes
12,
Dining
130
1222 No
.3
1
Yes
Yes
Yes
13
Family Room
380
3572 No
4
1
Yes
Yes
Yes
14
WIC 1
40
376 No
0
1
Yes
Yes
Yes
15
Bedroom 2
156
1466.4 No
2
1
1
Yes
Yes
Yes
16
Bath 2
72
676.8 No
0
1
Yes
Yes
Yes
17
Hall
55
517 No
0
1
No
Yes
Yes
18
Bath 3
42
394.8 No
0
1
Yes
Yes
Yes
19
WIC 3
30
282 No
0
1
Yes
Yes
Yes
20
Bedoom 3
143
1344.2 No
2
1
1
Yes
Yes
Yes
2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Toilet
loft
25 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulatio
M Bath
17 ft
151 ft2
____
1
0
0
3 Slab -On -Grade Edge Insulatio
Master Bedroom 22 ft
256 ft2
____
1
0
0
4SIab-On-Grade Edge Insulatio
M WIC
8 ft
104 ft2
___-
1
0
0
5 Slab -On -Grade Edge Insulatio
Laundry
9 ft
117 ft2
---_
1
0
0
6 Slab -On -Grade Edge Insulatio
Pantry
1 ft
72 ft2
____
1
0
0
7SIab-On-Grade Edge Insulatio
Hall 1
1 ft
98 ft2
1
0
0
8 Slab -On -Grade Edge Insulatio
Kitchen
1 ft
266 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulatio
Den
13 ft
130 ft2
----
1
0
0
10SIab-On-Grade Edge Insulatio
Foyer
9 ft
90 ft2
____
1
0
0
11SIab-On-Grade Edge Insulatio
Bedroom 1
17 ft
156 ft2
___-
1
0
0
12SIab-On-Grade Edge Insulatio
Dining
23 ft
130 ft2
--_-
1
0
0
13SIab-On-Grade Edge Insulatio
Family Room
17 ft
380 ft2
__--
1
0
0
14SIab-On-Grade Edge Insulatio
WIC 1
5 ft
40 ft2
____
1
0
0
15SIab-On-Grade Edge Insulatio
Bedroom 2
25 ft
156 ft2
____
1
0
0
16SIab-On-Grade Edge Insulatio
Bath 2
loft
72 ft2
----
1
0
0
17SIab-On-Grade Edge Insulatio
Hall 2
1 ft
55 ft2
----
1
0
0
18SIab-On-Grade Edge Insulatio
Bath 3
13 ft
42 ft2
____
1
0
0
19SIab-On-Grade Edge Insulatio
WIC 3
11 ft
30 ft2
----
1
0
0
20SIab-On-Grade Edge Insulatio
Bedoom 3
12 ft
143 ft2
____
1
0
0
ROOF
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
v # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2722 ft2
0 ft2 Light
N
0.6 No 0.9
No
20
22.62
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2513 ft2
N N
2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Toilet
0
Blown
25 ft2
0.1
Wood
2
Under Attic (Unvented) M Bath
0
Blown
151 ft2
0.1
Wood
3
Under Attic (Unvented) Master Bedroom 0
Blown
256 ft2
0.1
Wood
4
Under Attic (Unvented) M WIC
0
Blown
104 ft2
0.1
Wood
5
Under Attic (Unvented) Laundry
0
Blown
117 ft2
0.1
Wood
6
Under Attic (Unvented) Pantry
0
Blown
72 ft2
0.1
Wood
7
Under Attic (Unvented) Hall 1
0
Blown
98 ft2
0.1
Wood
8
Under Attic (Unvented) Kitchen
0
Blown
266 ft2
0.1
Wood
9
Under Attic (Unvented) Den
0
Blown
130 ft2
0.1
Wood
10
Under Attic (Unvented) Foyer
0
Blown
90 ft2
0.1
Wood
11
Under Attic (Unvented) Bedroom 1
0
Blown
156 ft2
0.1
Wood
12
Under Attic (Unvented) Dining
0
Blown
130 ft2
0.1
Wood
13
Under Attic (Unvented) Family Room
0
Blown
380 ft2
0.1
Wood
14
Under Attic (Unvented) WIC 1
0
Blown
40 ft2
0.1
Wood
15
Under Attic (Unvented) Bedroom 2
0
Blown
156 ft2
0.1
Wood
16
Under Attic (Unvented) Bath 2
0
Blown
72 ft2
0.1
Wood
17
Under Attic (Unvented) Hall 2
0
Blown
55 ft2
0.1
Wood
18
Under Attic (Unvented) Bath 3
0
Blown
42 ft2
0.1
Wood
19
Under Attic (Unvented) WIC 3
0
Blown
30 ft2
0.1
Wood
20
Under Attic (Unvented) Bedoom 3
0
Blown
143 ft2'
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
SpaceP-\/;;Iiipliprea
qnr1
N
Exterior Concrete Block - Int Insul Toilet
4.1
5
0 9
5
47.1 ft2
0
0
0.3
0
2
W
Exterior Concrete Block - Int Insul Toilet
4.1
5
0 9
5
47.1 ft2
0
0
0.3
0
3
N
Exterior Concrete Block - Int Insul M Bath
4.1
6
0 9
5
56.5 ft2
0
0
0.3
0
4
W
Exterior Concrete Block - Int Insul M Bath
4.1
11
0 9
5
103.6 ft2
0
0
0.3
0
5
N
Exterior Concrete Block - Int InsMaster Bedro
4.1
16
0 9
5
150.7 ft2
0
0
0.3
0
6
E
Exterior Concrete Block - Int InsMaster Bedro
4.1
6
0 9
5
56.5 ft2
0
0
0.3
0
7
W
Exterior Concrete Block - Int Insul M WIC
4.1
8
0 9
5
75.3 ft2
0
0
0.3
0
8
W
Exterior Concrete Block - Int Insul Laundry
4.1
9
0 9
5
84.8 ft2
0
0
0.3
0
9
S
Exterior Concrete Block - Int Insul Den
4.1
13
0 9
5
122.4 ft2
0
0
0.3
0
10
S
Exterior Concrete Block - Int Insul Foyer
4.1
9
0 9
5
84.8 ft2
0
0
0.3
0
11
E
Exterior Concrete Block - Int InsuBedroom 1
4.1
2
0 9
5
18.8 ft2
0
0
0.3
0
12
S
Exterior Concrete Block - Int InsuBedroom 1
4.1
12
0 9
5
113.0 ft2
0
0
0.3
0
13
W
Exterior Concrete Block - Int InsuBedroom 1
4.1
3
0 9
5
28.3 ft2
0
0
0.3
0
14
N
Exterior Concrete Block - Int Insul Dining
4.1
13
0 9
5
122.4 ft2
0
0
0.3
0
15
E
Exterior Concrete Block - Int Insul Dining
4.1
10
0 9
5
94.2 ft2
0
0
0.3
0
_ 16
N
Exterior Concrete Block - Int Ins6lamily Room
4.1
17
0 9
5
160.1 ft2
0
0
0.3
0
17
S
Exterior Concrete Block - Int Insul WIC 1
4.1
5
0 9
5
47.1 ft2
0
0
0.3
0
18
E
Exterior Concrete Block - Int InsuBedroom 2
4.1
13
0 9
5
122.4 ft2
0
0
0.3
0
19
S
Exterior Concrete Block - Int InsuBedroom 2
4.1
12
0 9
5
113.0 ft2
0
0
0.3
0
20
N
Exterior Concrete Block - Int Insul Bath 2
4.1
4
0 9
5
37.7 ft2
0
0
0.3
0
2/17/2021 4:37 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Below
Space
21
E
Exterior
Concrete Block - Int Insul
Bath 2
4.1
6
0
9 5
56.5 ft2
0
0
0.3
0
22
N
Exterior
Concrete Block - Int Insul
Bath 3
4.1
7
0
9 5
65.9 ft2
0
0
0.3
0
23
W
Exterior
Concrete Block - Int Insul
Bath 3
4.1
6
0
9 5
56.5 ft2
0
0
0.3
0
24
N
Exterior
Concrete Block - Int Insul
WIC 3
4.1
5
0
9 5
47.1 ft2
0
0
0.3
0
25
E
Exterior
Concrete Block - Int Insul
WIC 3
4.1
6
0
9 5
56.5 ft2
0
0
0.3
0
26
N
Exterior
Concrete Block - Int InsulBedoom
3
4.1
1
0
9 5
9.4 ft2
0
0
0.3
0
27
E
Exterior
Concrete Block - Int InsulBedoom 3
4.1
11
0
9 5
103.6 ft2
0
0
0.3
0
28
N
Garage
Frame - Woad
Den
11
10
9 4
93.3 ft2
0.23
0.3
0
_ 29
N
Garage
Frame - Wood
Kitchen
11
2
9 4
18.7 ft2
0.23
0.3
0
30
W
Garage
Frame - Wood
Hall 1
11
10
9 4
93.3 ft2
0.23
0.3
0
31
W
Garage
Frame - Wood
Laundry
11
13
9 4
121.3 ft2
0.23
0.3
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
Foyer
None
.39
5
8
6 10
38.7 ft2
2
W
Insulated
Hall 1
None
.39
3
8
24 ft2
3
N
Insulated
Bath 3
None
.39
2
6 8
13.3 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W 4
Vinyl Low-E Single
Yes
0.31
0.28
Y
6.0 ft2
1 ft 5 in
1 ft 4 in
None
None
2
N 5
Vinyl Low-E Single
Yes
0.31
0.28
Y
20.0 ft2
1 ft 5 in
1 ft 4 in
None
None
3
E 6
Vinyl Low-E Single
Yes
0.31
0.28
Y
15.0 ft2
1 ft 5 in
1 ft 4 in
None
None
4
W 8
Vinyl Low-E Single
Yes
0.31
0.28
Y
12.3 ft2
1 ft 5 in
1 ft 4 in
None
None
5
S 9
Vinyl Low-E Single
Yes
0.31
0.28
Y
30.0 ft2
1 ft 5 in
1 ft 4 in
None
None
6
S 12
Vinyl Low-E Single
Yes
0.31
0.28
Y
15.0 ft2
1 ft 5 in
1 ft 4 in
None
None
7
N 14
Vinyl Low-E Single
Yes
0.31
0.28
Y
30.0 ft2
1 ft 5 in
1 ft 4 in
None
None
8
E 15
Vinyl Low-E Single
Yes
0.31
0.28
Y
15.0 ft2
5 ft 0 in
1 ft 4 in
None
None
9
N 16
Metal Low-E Single
Yes
0.33
0.26
Y
82.0 ft2
10 ft 0 in
1 ft 4 in
None
None
10
S 19
Vinyl Low-E Single
Yes
0.31
0.28
Y
15.0 ft2
1 ft 5 in
1 ft 4 in
None
None
11
E 21
Vinyl Low-E Single
Yes
0.31
0.28
Y
6.0 ft2
1 ft 5 in
1 ft 4 in
None
None
12
N 22
Vinyl Low-E Single
Yes
0.31
0.28
Y
4.2 ft2
1 ft 5 in
1 ft 4 in
None
None
13
E 27
Vinyl Low-E Single
Yes
0.31
0.28
Y
15.0 ft2
1 ft 5 in
1 ft 4 in
None
None
2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
rORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
483 ft2
483 ft'
35 ft. 9.4 ft 11
INFILTRATION ,
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000298
1968.5 108 202.76 .0963 5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 41 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
/
V #
-- Supply --
Location R-Value Area
— Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 90 ft'
Attic
25 ft' Default Leakage Garage (Default) (Default)
1 1
2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
- FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan
Jan HFeb
Heating jxj
Feb
Mar
Mar
ki
Apr
ArfMay4
Ma
X Jun
Jun
X Jul
4 Jul
fX Au
[ A4
X Se
SepOct
f ]Oct
Nov
Nov
Dec
Dec
Ventin Jan
Feb
Mar
Apr
[
May
[ Jun
[ Jul
[[[ ]]] Aug
[ Se
[[[XXX] Oct X
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
'
Scjedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Toilet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8lbs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Den
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Family Room
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedoom 3
2/17/2021 4:37 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7