Loading...
HomeMy WebLinkAboutEnergy Code2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Comeau Residence Builder Name: Dave Golden Homes Street: TBD Slash Pince Trail Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Y U Owner: Comeau Residence Jurisdiction: St. Lucie County W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pytpnri behind piping and wirong. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire sprinkler cover nlates and walls or ceolanas, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 J FORM R405-2020 0 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. TBD Slash Pince Trail, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2081.10 ft2 b. Frame - Wood, Adjacent R=11.0 326.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2513.00 ft2 6. Conditioned floor area (ft2) 2513 b. N/A R= ft2 c. N/A R= ft2 7. Windows" Description Area 12. Ducts, location &insulation level R ft2 a. U-Factor: S I, U=0.31 g 183.50 ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 90 SHGC: SHGC=0.28 b. U-Factor: Sgl, U=0.33 82.00 ft2 SHGC: SHGC=0.26 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 41.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 4.270 ft. Area Weighted Average SHGC: 0.274 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.95 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2513.00 ft2 Credits (Performance method) CF, Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complie ith the Florida Energy Efficiency Code for Building Construction through the above a er y saving features which will be installed (or exceeded) in this home before final inspect 0therw se, i new EPL Display Card will be compl ted based on installed Code comp'an feature . Builder Signature: Date: ZZ 3 ZO Address of New Home: r��� / City/FL Zip: e *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 fi FORM R405-2020 „s i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Comeau Residence Builder Name: Dave Golden Homes Street: TBD Slash Pince Trail Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Comeau Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) h. New construction or existing New (From Plans) 10. Wall Type42407.7 sgft.) Insulation Area :2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2081.10 ftz b. Frame - Wood, Adjacent R=11.0 326.67 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ft' 11. Ceiling Types (2513.0 soft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2513.00 ft 6. Conditioned floor area above grade (ftz) 2513 b. N/A R= ftZ Conditioned floor area below grade (ft2) 0 c. N/A R= ftZ 7. Windows(265.5 soft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft' 6 90 a. U-Factor: Sgl, U=0.31 183.50 ftZ SHGC: SHGC=0.28 b. U-Factor: Sgl, U=0.33 82.00 ftZ 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 41.0 SEER:16.00 c. U-Factor: N/A ft' SHGC: Area Weighted Average Overhang Depth: 4.270 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.274 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A a. Electric Gap: 50 gallons 9. Floor Types (2613.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2513.00 ftz b. Conservation features b. N/A R= ft' None c. N/A R= ft' 16. Credits CF, Pstat Glass/Floor Area: 0.106 Total Proposed Modified Loads: 74.03 PASS Total Baseline Loads: 74.41 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed t �. DATE: 2-18-2021 this building will be inspected for, compliance with Section 553.908 - " I hereby certify that this buildin a desig d, i compliance Florida Statutes.,. . with the Florida Energy Code.i7 y'1� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 . .FORM R405-2020 I INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Comeau Residence Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2513 Lot # Owner Name: Comeau Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Dave Golden Homes Rotate Angle: 0 Street: TBD Slash Pince Trail Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: - CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2513 23622.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Toilet 25 235 No 0 1 Yes Yes Yes 2 M Bath 151 1419.4 No 1 1 Yes Yes Yes 3 Master Bedroom 256 2406.4 No 2 1 1 Yes Yes Yes 4 M WIC 104 977.6 No 1 1 Yes Yes Yes 5 Laundry 117 1099.8 No 1 1 Yes Yes Yes 6 Pantry 72 676.8 No 0 1 No Yes Yes 7 Hall 98 921.2 No 0 1 No Yes Yes 8 Kitchen 266 2500.4 Yes 2 1 No Yes Yes 9 Den 130 1222 No 2 1 Yes Yes Yes 10 Foyer 90 846 No 0 1 Yes Yes Yes 11 Bedroom 1 156 1466.4 No 2 1 1 Yes Yes Yes 12, Dining 130 1222 No .3 1 Yes Yes Yes 13 Family Room 380 3572 No 4 1 Yes Yes Yes 14 WIC 1 40 376 No 0 1 Yes Yes Yes 15 Bedroom 2 156 1466.4 No 2 1 1 Yes Yes Yes 16 Bath 2 72 676.8 No 0 1 Yes Yes Yes 17 Hall 55 517 No 0 1 No Yes Yes 18 Bath 3 42 394.8 No 0 1 Yes Yes Yes 19 WIC 3 30 282 No 0 1 Yes Yes Yes 20 Bedoom 3 143 1344.2 No 2 1 1 Yes Yes Yes 2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Toilet loft 25 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulatio M Bath 17 ft 151 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulatio Master Bedroom 22 ft 256 ft2 ____ 1 0 0 4SIab-On-Grade Edge Insulatio M WIC 8 ft 104 ft2 ___- 1 0 0 5 Slab -On -Grade Edge Insulatio Laundry 9 ft 117 ft2 ---_ 1 0 0 6 Slab -On -Grade Edge Insulatio Pantry 1 ft 72 ft2 ____ 1 0 0 7SIab-On-Grade Edge Insulatio Hall 1 1 ft 98 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Kitchen 1 ft 266 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulatio Den 13 ft 130 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Foyer 9 ft 90 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulatio Bedroom 1 17 ft 156 ft2 ___- 1 0 0 12SIab-On-Grade Edge Insulatio Dining 23 ft 130 ft2 --_- 1 0 0 13SIab-On-Grade Edge Insulatio Family Room 17 ft 380 ft2 __-- 1 0 0 14SIab-On-Grade Edge Insulatio WIC 1 5 ft 40 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulatio Bedroom 2 25 ft 156 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulatio Bath 2 loft 72 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulatio Hall 2 1 ft 55 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulatio Bath 3 13 ft 42 ft2 ____ 1 0 0 19SIab-On-Grade Edge Insulatio WIC 3 11 ft 30 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulatio Bedoom 3 12 ft 143 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2722 ft2 0 ft2 Light N 0.6 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2513 ft2 N N 2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Toilet 0 Blown 25 ft2 0.1 Wood 2 Under Attic (Unvented) M Bath 0 Blown 151 ft2 0.1 Wood 3 Under Attic (Unvented) Master Bedroom 0 Blown 256 ft2 0.1 Wood 4 Under Attic (Unvented) M WIC 0 Blown 104 ft2 0.1 Wood 5 Under Attic (Unvented) Laundry 0 Blown 117 ft2 0.1 Wood 6 Under Attic (Unvented) Pantry 0 Blown 72 ft2 0.1 Wood 7 Under Attic (Unvented) Hall 1 0 Blown 98 ft2 0.1 Wood 8 Under Attic (Unvented) Kitchen 0 Blown 266 ft2 0.1 Wood 9 Under Attic (Unvented) Den 0 Blown 130 ft2 0.1 Wood 10 Under Attic (Unvented) Foyer 0 Blown 90 ft2 0.1 Wood 11 Under Attic (Unvented) Bedroom 1 0 Blown 156 ft2 0.1 Wood 12 Under Attic (Unvented) Dining 0 Blown 130 ft2 0.1 Wood 13 Under Attic (Unvented) Family Room 0 Blown 380 ft2 0.1 Wood 14 Under Attic (Unvented) WIC 1 0 Blown 40 ft2 0.1 Wood 15 Under Attic (Unvented) Bedroom 2 0 Blown 156 ft2 0.1 Wood 16 Under Attic (Unvented) Bath 2 0 Blown 72 ft2 0.1 Wood 17 Under Attic (Unvented) Hall 2 0 Blown 55 ft2 0.1 Wood 18 Under Attic (Unvented) Bath 3 0 Blown 42 ft2 0.1 Wood 19 Under Attic (Unvented) WIC 3 0 Blown 30 ft2 0.1 Wood 20 Under Attic (Unvented) Bedoom 3 0 Blown 143 ft2' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceP-\/;;Iiipliprea qnr1 N Exterior Concrete Block - Int Insul Toilet 4.1 5 0 9 5 47.1 ft2 0 0 0.3 0 2 W Exterior Concrete Block - Int Insul Toilet 4.1 5 0 9 5 47.1 ft2 0 0 0.3 0 3 N Exterior Concrete Block - Int Insul M Bath 4.1 6 0 9 5 56.5 ft2 0 0 0.3 0 4 W Exterior Concrete Block - Int Insul M Bath 4.1 11 0 9 5 103.6 ft2 0 0 0.3 0 5 N Exterior Concrete Block - Int InsMaster Bedro 4.1 16 0 9 5 150.7 ft2 0 0 0.3 0 6 E Exterior Concrete Block - Int InsMaster Bedro 4.1 6 0 9 5 56.5 ft2 0 0 0.3 0 7 W Exterior Concrete Block - Int Insul M WIC 4.1 8 0 9 5 75.3 ft2 0 0 0.3 0 8 W Exterior Concrete Block - Int Insul Laundry 4.1 9 0 9 5 84.8 ft2 0 0 0.3 0 9 S Exterior Concrete Block - Int Insul Den 4.1 13 0 9 5 122.4 ft2 0 0 0.3 0 10 S Exterior Concrete Block - Int Insul Foyer 4.1 9 0 9 5 84.8 ft2 0 0 0.3 0 11 E Exterior Concrete Block - Int InsuBedroom 1 4.1 2 0 9 5 18.8 ft2 0 0 0.3 0 12 S Exterior Concrete Block - Int InsuBedroom 1 4.1 12 0 9 5 113.0 ft2 0 0 0.3 0 13 W Exterior Concrete Block - Int InsuBedroom 1 4.1 3 0 9 5 28.3 ft2 0 0 0.3 0 14 N Exterior Concrete Block - Int Insul Dining 4.1 13 0 9 5 122.4 ft2 0 0 0.3 0 15 E Exterior Concrete Block - Int Insul Dining 4.1 10 0 9 5 94.2 ft2 0 0 0.3 0 _ 16 N Exterior Concrete Block - Int Ins6lamily Room 4.1 17 0 9 5 160.1 ft2 0 0 0.3 0 17 S Exterior Concrete Block - Int Insul WIC 1 4.1 5 0 9 5 47.1 ft2 0 0 0.3 0 18 E Exterior Concrete Block - Int InsuBedroom 2 4.1 13 0 9 5 122.4 ft2 0 0 0.3 0 19 S Exterior Concrete Block - Int InsuBedroom 2 4.1 12 0 9 5 113.0 ft2 0 0 0.3 0 20 N Exterior Concrete Block - Int Insul Bath 2 4.1 4 0 9 5 37.7 ft2 0 0 0.3 0 2/17/2021 4:37 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 21 E Exterior Concrete Block - Int Insul Bath 2 4.1 6 0 9 5 56.5 ft2 0 0 0.3 0 22 N Exterior Concrete Block - Int Insul Bath 3 4.1 7 0 9 5 65.9 ft2 0 0 0.3 0 23 W Exterior Concrete Block - Int Insul Bath 3 4.1 6 0 9 5 56.5 ft2 0 0 0.3 0 24 N Exterior Concrete Block - Int Insul WIC 3 4.1 5 0 9 5 47.1 ft2 0 0 0.3 0 25 E Exterior Concrete Block - Int Insul WIC 3 4.1 6 0 9 5 56.5 ft2 0 0 0.3 0 26 N Exterior Concrete Block - Int InsulBedoom 3 4.1 1 0 9 5 9.4 ft2 0 0 0.3 0 27 E Exterior Concrete Block - Int InsulBedoom 3 4.1 11 0 9 5 103.6 ft2 0 0 0.3 0 28 N Garage Frame - Woad Den 11 10 9 4 93.3 ft2 0.23 0.3 0 _ 29 N Garage Frame - Wood Kitchen 11 2 9 4 18.7 ft2 0.23 0.3 0 30 W Garage Frame - Wood Hall 1 11 10 9 4 93.3 ft2 0.23 0.3 0 31 W Garage Frame - Wood Laundry 11 13 9 4 121.3 ft2 0.23 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Foyer None .39 5 8 6 10 38.7 ft2 2 W Insulated Hall 1 None .39 3 8 24 ft2 3 N Insulated Bath 3 None .39 2 6 8 13.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 4 Vinyl Low-E Single Yes 0.31 0.28 Y 6.0 ft2 1 ft 5 in 1 ft 4 in None None 2 N 5 Vinyl Low-E Single Yes 0.31 0.28 Y 20.0 ft2 1 ft 5 in 1 ft 4 in None None 3 E 6 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 4 W 8 Vinyl Low-E Single Yes 0.31 0.28 Y 12.3 ft2 1 ft 5 in 1 ft 4 in None None 5 S 9 Vinyl Low-E Single Yes 0.31 0.28 Y 30.0 ft2 1 ft 5 in 1 ft 4 in None None 6 S 12 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 7 N 14 Vinyl Low-E Single Yes 0.31 0.28 Y 30.0 ft2 1 ft 5 in 1 ft 4 in None None 8 E 15 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft2 5 ft 0 in 1 ft 4 in None None 9 N 16 Metal Low-E Single Yes 0.33 0.26 Y 82.0 ft2 10 ft 0 in 1 ft 4 in None None 10 S 19 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 11 E 21 Vinyl Low-E Single Yes 0.31 0.28 Y 6.0 ft2 1 ft 5 in 1 ft 4 in None None 12 N 22 Vinyl Low-E Single Yes 0.31 0.28 Y 4.2 ft2 1 ft 5 in 1 ft 4 in None None 13 E 27 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None 2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 rORM R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 483 ft2 483 ft' 35 ft. 9.4 ft 11 INFILTRATION , # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000298 1968.5 108 202.76 .0963 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 41 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / V # -- Supply -- Location R-Value Area — Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 90 ft' Attic 25 ft' Default Leakage Garage (Default) (Default) 1 1 2/17/2021 4:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 - FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Jan HFeb Heating jxj Feb Mar Mar ki Apr ArfMay4 Ma X Jun Jun X Jul 4 Jul fX Au [ A4 X Se SepOct f ]Oct Nov Nov Dec Dec Ventin Jan Feb Mar Apr [ May [ Jun [ Jul [[[ ]]] Aug [ Se [[[XXX] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours ' Scjedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Den Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Family Room Default(8lbs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedoom 3 2/17/2021 4:37 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7