Loading...
HomeMy WebLinkAboutCompaction REVISED - signedHeadquarters 11345 U.S. Highway 1 Ar Sebastian, FL. 32958 &J ILVL Orlando 723 Progress Way Sanford, FL. 32771 May 28, 2021 CONTRACTOR: St. Lucie Site Development P.O. Box 1132 Fort Pierce, Florida JOB LOCATION: 4906 Buchanan Drive Fort Pierce, Florida PERMIT #: 2103-0018 To Whom it may concern, Mailing ENGINEERING PO Box 78-1377 AND TESTING Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net As requested, we tested the compacted fill for the Compacted Foundation Fill. KSM JOB #: 213912-1d/CFAo To determine if the fill was properly compacted on the pad to a depth of 3 feet, we performed nucleardensity tests on the top two feet. To estimate the soil density below a depth of 2 feet we used a Static Cone Penetrometer. During the tests, a shaft with a conical point is pushed through soil and the soil resistance measured on a calibrated gauge. After the soil resistance is measured, the hole is advanced with a hand -auger in 1-foot increments to permit a continuation of measurement of density versus depth. Test Results: Nuclear density tests performed on the top 2 feet indicates the compaction exceeds the project specifications of 95% (ASTM 1557). Static Cone Penetrometer readings indicate the compacted backfill below 2 feet are generally well compacted to a depth of 3 feet. Based on the nuclear density tests and Static Cone Penetrometer readings, it appears the fill on the house pad was properly compacted. Should you have any questions, please feel free to contact our office. Respectfully, This Item has been electronically signed and sealed by Bryan E. Dahlke, PE FL, Lic. 81439 n the date stated directly t, the right using a digital signature. Printed copies of this documents are not nsidered signed and sealed and the signature must be verified -any electronic mpies. Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 05/28/21 Digitally signed by Bryan E Dahlke Date: 2021.05.28 13:37:03 -04'00' Email: St Lucie Building Department; slsdevinc@aol.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED PERMIT #: CONTRACTOR: JOB LOCATION: 1P 40 1 t ENGINEERING i117iVi AND TESTING SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 May 27, 2021 2103-0018 St. Lucie Site Development 4906 Buchanan Drive Fort Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # NUC # Nuc Model: Nuc Serial #: 213912-1d/CF/jo 234 MC -DR M D60308234 ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 N.W. 0" - 12" 45 108.1 111.3 97.1% 2 N.E. 50 109.6 98.5% 3 Center 45 108.4 97.4% 4 S.E. 50 108.8 97.8% 5 S.W. 45 109.3 98.2 % 6 N.E. 12" - 24" 50+ 108.3 97.3% 7 S.W. " 50+ 108.7 97.7% Soil Description: Gray/Brown Sand with traces of Clay In Place Moisture: 7.4% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 111.3 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: 113.0 I I I I I I I W E 112.0.. ..—�.—.—.. ..—�..—.�.—..� _ G111.0..�..-4.—.�—.. I.—..�.._ H I I I I I I T 1R0.0 —. —1..—.I. ..r.._ P Y I I I I I I 109.0 _..—...... C I I I I I I 108.0 �..�. _l._.1—..�..�.._.I._..�.._ F I I I I I I 107.0 rt.._I._.1—..�..�.._.I._..r.._ 106.0 �..rt..—:——..t..�..—.�.—..�..� 6 7 8 9 10 11 12 13 14 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Bryan E. Dahlke, P.E. V.P. of Engineering PE# 81439 5/28/2021 Email: St Lucie Building Department; slsdevinc@aol.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 *l 40 1 t ENGINEERING i117jVi AND TESTING Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net