Loading...
HomeMy WebLinkAboutCompaction Revised - signedHeadquarters 1W C IL � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 1 %% AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net REVISED: PERMIT ADDED May 27, 2021 DATE TESTED: May 14, 2021 KSM JOB #: 213633-1d/AH/bm NUC # 240 PERMIT #: 21010333 Nuc Model: MC-1 Elite Nuc Serial #: 31240 CONTRACTOR: R & E Loader Service JOB LOCATION: 5313 S 25th Street Ft Pierce, Florida ITEM TESTED: Compacted Foundation Fill - 1st & 2nd Lift TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 First Lift S.E. 0" - 12" 40+ D 111.8 114.4 97.7% 2 First Lift S.W. 112.7 98.5% 3 First Lift Center 110.7 96.8% 4 First Lift N.W. 110.9 96.9% 5 First Lift N.E. 112.5 98.3% 6 Second Lift S.E. 12" - 24" 45+ D 111.5 97.5% 7 Second Lift S.W. 113.2 99.0% 8 Second Lift Center 112.6 98.4% 9 Second Lift N.W. 111.8 97.7% 10 Second Lift N.E. " Soil Description: 116.0 - I I I I I I I Tan Brown Sand with Some Clay W E I I I I I I In Place Moisture: 11.0% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 114.4 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Digitally signed by Bryan E Dahlke Date: 2021.05.27 15:39:02 -04'00' 115.0 t—..,..—..—........—..�..,..—..—.._ H I I I I I 13.0—..�..—.1_..t.. I._..r..�.. I—.._ P y I I I I I 112.0 4—.. i.. — .i — .. 1 .. — i. — ..� .. i.. — .i — .._ C I I I I I I I 111.0—..—..—.—..—..— .—.._..—..—.,—.._ F I I I I I I I 110.0 i—.1—..+.._1.—..l..-4..—.1—.._ • I I I I I I I 109.0 �..�..—.;—....—;.—..�..�..—.; 6 7 8 9 10 11 12 13 14 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Bryan E. Dahlke, P.E. V.P. of Engineering PE# 81439 5/27/2021 Email to: mcarthuresther@bellsouth.net Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE