HomeMy WebLinkAbout213633-2d Compaction Revised - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 REVISED: PERMIT ADDED DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: VP 40 1 t ENGINEERING it f7iVi AND TESTING SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 May 27, 2021 May 24, 2021 21010333 R & E Loader Service 5313 S 25th Street Ft Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #: 213633-2d/CF/bm NUC # 234 Nuc Model: MC -DR Nuc Serial #: MD60308234 ITEM TESTED: Compacted Foundation Fill - Final Lift TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 S.E. 0" - 12" 50+ 111.8 114.4 97.7% 2 S.W. 1 111.5 1197.5% 3 Center 1 112.3 1198.2% 4 N.W. 1 110.9 1196.9% 5 N.E. 1 112.8 1198.6% Soil Description: Brown/Tan Sand with Some Clay In Place Moisture: 7.4% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 114.4 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation This item has been electrnnica l ly signed and ea led by Bryan E. Dahlke, PE FL. Lic81439 Respectfully Submitted: -the date stated directly th the right using a digital signature. Printed copies of this documents are not nsidered signed and sealed and the signature must be verified - any electronic copies. Digitally signed by Bryan E Dahlke Date: 2021.05.27 15:38:35-04'00' Bryan E. Dahlke, P.E. V.P. of Engineering PE# 81439 5/27/2021 Email to: mcarthuresther@bellsouth.net 116.0 W I I I I I I I E115.0 L.. —.. .._r._..�..�.._.._.._ I H114.0 �.. T I I I I I 113.0 j— J.._.I_..1.. I._..L..J.. I_.._ P I I I I I I I 112.0 '••—I••— C i F 111.0 �••— I 110.0 — D I ' I R 109.0 Y 6 7 I—.. _I._..lk-..-4.._.T—.._ I I I I I I I I I I I I I_..T.._I._..F..-1.._.1_.._ I I I I I I 8 9 10 11 12 13 14 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE