Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD RECEIVED ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 7848 Germany Canal Road, Fort Pierce, FL, 34987 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.30 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A New (From Plans) 10. Wall Type and Insulation Insulation Detached a. Concrete Block - Int Insul, Exterior R=4.1 b. Interior Frame -Wood, Interior R=13.0 1 c. N/A R= 3 d. N/A R= 11. Ceiling Type and insulation level Insulation No a. Roof Deck (Unvented) R=20.0 2852 b. N/A R= Area c. N/A R= 510.76 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: Utility b. Sup: Attic, Ret: Master Bedroom, AH: WIC 2 ft2 ft2 ft2 9.172 ft. 0.300 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2852.00 ft2 b. N/A R= ft2 c. N/A R= ft2 13. Cooling systems a. Central Unit b. Central Unit 14. Heating systems a. Electric Strip Heat b. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code com tture Builder Signature: /"'.r Date: Address of NeX ome.-7 848 (Werrt�GnY �Y1Gc l C�ty�FL Zip: 'P5L I FL 34 q APR 0 8 1011 Permitting Dapartment St. Lucie County Area 2501.20 ft2 386.08 ft2 ft2 ft2 Area 2852.00 ft2 ft2 ft2 R ft2 6 85 6 40 kBtu/hr Efficiency 35.4 SEER:16.00 18.0 SEER:16.00 kBtu/hr Efficiency 27.0 COP:1.00 17.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF. Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/30/2021 9:53 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 RECEIVED a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA APR 0 8 2021 Project Name: Jay Residence Builder Name: Permitting Dapartment Street: 7848 Germany Canal Road Permit Office: St. Lucie County St. Lucie County City, State, Zip: Fort Pierce , FL, 34987 Permit Number: Y U Owner: Jay Residence Jurisdiction: St. Lucie County W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed eatth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and _e2daadJ&W=ipJng Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceelonas. a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400. 3/30/2021 9:53 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performapampod Project Name: Jay Residence Builder Name: APR ® 8 ZRI Street: 7848 Germany Canal Road Permit Office: St. Lucie County Permitting Department City, State, Zip: Fort Pierce , FL, 34987 Permit Number: Lucie St. Lucie County Owner: Jay Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type42887.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2501.20 ft2 b. Interior Frame - Wood, Interior R=13.0 386.08 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (2852.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2852.00 ft2 6. Conditioned floor area above grade (ft2) 2852 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(510.8 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Utility R ft2 6 85 a. U-Factor: Sgl, U=0.65 510.76 ft2 b. Sup: Attic, Ret: Master Bedroom, AH: WIC 2 6 40 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.4 SEER:16.00 c. U-Factor: N/A ft2 b. Central Unit 18.0 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 9.172 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.300 a. Electric Strip Heat 27.0 COP:1.00 b. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2852.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2852.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Total Proposed Modified Loads: 84.99 Glass/Floor Area: 0.179 PASS Total Baseline Loads: 86.19 I hereby certify that the plans and specifications covered by Review of the plans and Q 1114E STA this calculation are in compliance with the Florida Energy specifications covered by this 1+. Q Code. calculation indicates compliance TOO with the Florida Energy Code. Before construction is completed aV PREPARE DATE: this building will be inspected for compliance with Section 553.908 y. w I hereby certify that this building, as-cle&ign is ' mpliance Florida Statutes. y� with the Florida Energy CodeObt5 OWNER/ ` BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLI5T REPORT PROJECT Title: Jay Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2852 Lot # Owner Name: Jay Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 7848 Germany Canal R Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34987 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Master 748 7352.2 2 Main Living 2104 19777.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bath 3 78 733.2 No 0 1 Yes Yes Yes 2 Bedroom 3 156 1466.4 No 1 1 1 Yes Yes Yes 3 Bedroom 2 176 1654.4 No 1 1 1 Yes Yes Yes 4 Hall 56 526.4 No 0 1 Yes Yes Yes 5 Closet 3 30 282 No 0 1 No Yes Yes 6 Closet 2 30 282 No 0 1 No Yes Yes 7 Bath 2 84 789.6 No 0 1 Yes Yes Yes 8 Utility 140 1316 No 0 1 Yes Yes Yes 9 Hall 52 488.8 No 0 1 Yes Yes Yes 10 Pantry 49 460.6 No 0 1 Yes Yes Yes 11 Den 155 1457 No 0 1 Yes Yes Yes 12 Foyer 78 733.2 No 0 1 Yes Yes Yes 13 Living Room 378 3553.2 No 2 1 Yes Yes Yes 14 Dining 154 1447.6 No 0 1 Yes Yes Yes 15 Kitchen 360 3384 Yes 2 1 Yes Yes Yes 16 Hall 128 1203.2 No 0 1 No Yes Yes 17 Master Bath 211 1983.4 No 2 1 Yes Yes Yes 18 Toilet 32 300.8 No 1 1 Yes Yes Yes 19 WIC 1 121 1137.4 No 1 1 Yes Yes Yes 20 Master Bedroom 321 3338.4 No 2 1 1 Yes Yes Yes 21 WIC 2 63 592.2 No 1 1 Yes Yes Yes 3/30/2021 9:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bath 3 19 ft 78 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio Bedroom 3 12 ft 156 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 2 12 ft 176 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio Hall 2 4 ft 56 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio Closet 3 1 ft 30 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulatio Closet 2 1 ft 30 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulatio Bath 2 6 ft 84 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio Utility 27 ft 140 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio Hall 4 ft 52 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Pantry 7 ft 49 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio Den 23 ft 155 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Foyer 12 ft 78 ft2 __-- 1 0 0 13SIab-On-Grade Edge Insulatio Living Room 18 ft 378 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulatio Dining 25 ft 154 ft2 ---- 1 0 0 15Slab-On-Grade Edge Insulatio Kitchen 4 ft 360 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulatio Hall 3 1 ft 128 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulatio Master Bath 38 ft 211 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulatio Toilet 4 ft 32 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulatio WIC 1 11 ft 121 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulatio Master Bedroom 34 ft 321 ft2 ---- 1 0 0 21SIab-On-Grade Edge Insulatio WIC 2 2 ft 63 ft2 __-- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3302 ft2 0 ft2 Medium N 0.6 No 0.9 No 20 30.26 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2852 ft2 N N 3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Bath 3 0 Blown 78 ft2 0.1 Wood 2 Under Attic (Unvented) Bedroom 3 0 Blown 156 ft2 0.1 Wood 3 Under Attic (Unvented) Bedroom 2 0 Blown 176 ft2 0.1 Wood 4 Under Attic (Unvented) Hall 2 0 Blown 56 ft2 0.1 Wood 5 Under Attic (Unvented) Closet 3 0 Blown 30 ft2 0.1 Wood 6 Under Attic (Unvented) Closet 2 0 Blown 30 ft2 0.1 Wood 7 Under Attic (Unvented) Bath 2 0 Blown 84 ft2 0.1 Wood 8 Under Attic (Unvented) Utility 0 Blown 140 ft2 0.1 Wood 9 Under Attic (Unvented) Hall 0 Blown 52 ft2 0.1 Wood 10 Under Attic (Unvented) Pantry 0 Blown 49 ft2 0.1 Wood 11 Under Attic (Unvented) Den 0 Blown 155 ft2 0.1 Wood 12 Under Attic (Unvented) Foyer 0 Blown 78 ft2 0.1 Wood 13 Under Attic (Unvented) Living Room 0 Blown 378 ft2 0.1 Wood 14 Under Attic (Unvented) Dining 0 Blown 154 ft2 0.1 Wood 15 Under Attic (Unvented) Kitchen 0 Blown 360 ft2 0.1 Wood 16 Under Attic (Unvented) Hall 3 0 Blown 128 ft2 0.1 Wood 17 Under Attic (Unvented) Master Bath 0 Blown 211 ft2 0.1 Wood 18 Under Attic (Unvented) Toilet 0 Blown 32 ft2 0.1 Wood 19 Under Attic (Unvented) WIC 1 0 Blown 121 ft2 0.1 Wood 20 Under Attic (Unvented) Master Bedroom 0 Blown 321 ft2 0.1 Wood 21 Under Attic (Unvented) WIC 2 0 Blown 63 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo # nrnt Space To Wall Type1 w N Exterior Concrete Block - Int Insul Bath 3 4.1 6 0 9 5 56.5 ft2 0 0 0.4 0 2 E Exterior Concrete Block - Int Insul Bath 3 4.1 13 0 9 5 122.4 ft2 0 0 0.4 0 3 N Exterior Concrete Block - Int InsuBedroom 3 4.1 12 0 9 5 113.0 ft2 0 0 0.4 0 4 N Exterior Concrete Block - Int InsuBedroom 2 4.1 12 0 9 5 113.0 ft2 0 0 0.4 0 5 E Exterior Concrete Block - Int Insul Hall 2 4.1 4 0 9 5 37.7 ft2 0 0 0.4 0 6 N Exterior Concrete Block - Int Insul Bath 2 4.1 6 0 9 5 56.5 ft2 0 0 0.4 0 7 N Exterior Concrete Block - Int Insul Utility 4.1 10 0 9 5 94.2 ft2 0 0 0.4 0 _ 8 S Exterior Concrete Block - Int Insul Utility 4.1 3 0 9 5 28.3 ft2 0 0 0.4 0 9 W Exterior Concrete Block - Int Insul Utility 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 10 W Exterior Concrete Block - Int Insul Hall 4.1 4 0 9 5 37.7 ft2 0 0 0.4 0 11 W Exterior Concrete Block - Int Insul Pantry 4.1 7 0 9 5 65.9 ft2 0 0 0.4 0 12 N Exterior Concrete Block - Int Insul Den 4.1 6 0 9 5 56.5 ft2 0 0 0.4 0 13 S Exterior Concrete Block - Int Insul Den 4.1 4 0 9 5 37.7 ft2 0 0 0.4 0 14 W Exterior Concrete Block - Int Insul Den 4.1 13 0 9 5 122.4 ft2 0 0 0.4 0 15 E Exterior Concrete Block - Int Insul Foyer 4.1 2 0 9 5 18.8 ft2 0 0 0.4 0 16 W Exterior Concrete Block - Int Insul Foyer 4.1 10 0 9 5 94.2 ft2 0 0 0.4 0 17 S WIC 2 Interior Frame - Wood Foyer 13 9 0 9 5 84.8 ft2 0 0.25 0.8 0 18 E Exterior Concrete Block - Int Insdliving Room 4.1 18 0 9 5 169.5 ft2 0 0 0.4 0 19 W Master B Interior Frame - Wood Living Room 13 3 0 9 5 28.3 ft2 0 0.25 0.8 0 3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 20 S Master B Interior Frame - Wood Living Room 13 21 0 9 5 197.8 ft2 0 0.25 0.8 0 _21 E Exterior Concrete Block - Int Insul Dining 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 _22 S Exterior Concrete Block - Int Insul Dining 4.1 11 0 9 5 103.6 ft2 0 0 0.4 0 23 E Exterior Concrete Block - Int Insul Kitchen 4.1 4 0 9 5 37.7 ft2 0 0 0.4 0 24 S Master B Interior Frame - Wood Hall 3 13 4 0 9 5 37.7 ft2 0 0.25 0.8 0 25 W WIC 2 Interior Frame - Wood Hall 3 13 4 0 9 5 37.7 ft2 0 0.25 0.8 0 26 N Exterior Concrete Block - Int InsLMaster Bath 4.1 9 0 9 5 84.8 ft2 0 0 0.4 0 27 S Exterior Concrete Block - Int InsifUlaster Bath 4.1 9 0 9 5 84.8 ft2 0 0 0.4 0 28 W Exterior Concrete Block - Int InsUillaster Bath 4.1 20 0 9 5 188.3 ft2 0 0 0.4 0 29 S Exterior Concrete Block- Int Insul Toilet 4.1 4 0 9 5 37.7 ft2 0 0 0.4 0 30 S Exterior Concrete Block - Int Insul WIC 1 4.1 11 0 9 5 103.6 ft2 0 0 0.4 0 31 E Exterior Concrete Block - Int InsMaster Bedro 4.1 15 0 10 5 156.3 ft2 0 0 0.4 0 32 S Exterior Concrete Block - Int InsMaster Bedro 4.1 19 0 10 5 197.9 ft2 0 0 0.4 0 33 W Exterior Concrete Block- Int Insul WIC 2 4.1 2 0 9 5 18.8 ft2 0 0 0.4 0 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC LI-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.65 0.3 Y 5.8 ft2 1 ft 0 in 1 ft 4 in None None 2 N 3 Vinyl Low-E Single Yes 0.65 0.3 Y 17.5 ft2 1 ft 0 in 1 ft 4 in None None 3 N 4 Vinyl Low-E Single Yes 0.65 0.3 Y 17.5 ft2 1 ft 0 in 1 ft 4 in None None 4 E 5 Vinyl Low-E Single Yes 0.65 0.3 Y 22.7 ft2 2 ft 0 in 1 ft 4 in None None 5 N 6 Vinyl Low-E Single Yes 0.65 0.3 Y 6.0 ft2 1 ft 0 in 1 ft 4 in None None 6 N 7 Vinyl Low-E Single Yes 0.65 0.3 Y 24.0 ft2 2 ft 0 in 1 ft 4 in None None 7 W 9 Vinyl Low-E Single Yes 0.65 0.3 Y 18.7 ft2 1 ft 0 in 1 ft 4 in None None 8 W 10 Vinyl Low-E Single Yes 0.65 0.3 Y 10.0 ft2 1 ft 0 in 1 ft 4 in None None 9 W 11 Vinyl Low-E Single Yes 0.65 0.3 Y 10.0 ft2 1 ft 0 in 1 ft 4 in None 'None 10 W 14 Vinyl Low-E Single Yes 0.65 0.3 Y 30.0 ft2 1 ft 0 in 1 ft 4 in None None 11 W 16 Vinyl Low-E Single Yes 0.65 0.3 Y 41.0 ft2 14 ft 0 in 1 ft 4 in None None 12 E 18 Vinyl Low-E Single Yes 0.65 0.3 Y 128.0 ft2 18 ft 0 in 1 ft 4 in None None 13 E 21 Vinyl Low-E Single Yes 0.65 0.3 Y 40.0 ft2 8 ft 0 in 1 ft 4 in None None 14 S 22 Vinyl Low-E Single Yes 0.65 0.3 Y 41.0 ft2 12 ft 0 in 1 ft 4 in None None 15 W 28 Vinyl Low-E Single Yes 0.65 0.3 Y 18.7 ft2 1 ft 0 in 1 ft 4 in None None 16 S 29 Vinyl Low-E Single Yes 0.65 0.3 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None 17 S 30 Vinyl Low-E Single Yes 0.65 0.3 Y 8.0 ft2 1 ft 0 in 1 ft 4 in None None 18 E 31 Vinyl Low-E Single Yes 0.65 0.3 Y 40.4 ft2 18 ft 0 in 1 ft 4 in None None 19 S 32 Vinyl Low-E Single Yes 0.65 0.3 Y 27.5 ft2 1 ft 0 in 1 ft 4 in None None 3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000362 2713 148.84 279.43 .1161 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 27 kBtu/hr COP:1 17 kBtu/hr 2 1 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Singl SEER: 16 35.4 kBtu/hr cfm Sing[ SEER: 16 18 kBtu/hr cfm 0.7 2 0.7 1 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Utility 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS V/ # -Supply ---- Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 85 ft2 Attic 6 40 ft2 Attic 20 ft2 Prop. Leak Free Utility --- cfm 63.1 cfm 0.03 0.50 Master Bedro 5 ft2 Prop. Leak Free WIC 2 --- cfm 22.4 cfm , 0.03 0.50 1 1 2 2 TEMPERATURES Programable Thermostat: Y CoolingJan Feb Mar Heatinf X� Jan f X� Feb Mar Ventin [ Jan [ Feb X Mar Ceiling Fans: Apr Ma rj Jun X Jul X Au Se Apr IMayJun I Jul IAu�XjSeP f A r May Jun JUI Aug Se [X Oct Nov Oct Nov Oct HNov Dec XDec [ Dec 3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 utility Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Den Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Living Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Defauk(8 Ibs/sq.ft. ft2 ft 0.3 Hall 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7