HomeMy WebLinkAboutEnergy CodeFORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
RECEIVED
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
7848 Germany Canal Road, Fort Pierce, FL, 34987
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows-
Description
a. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.30
b. U-Factor:
N/A
SHGC:
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
New (From Plans)
10. Wall Type and Insulation
Insulation
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
b. Interior Frame -Wood, Interior
R=13.0
1
c. N/A
R=
3
d. N/A
R=
11. Ceiling Type and insulation level
Insulation
No
a. Roof Deck (Unvented)
R=20.0
2852
b. N/A
R=
Area
c. N/A
R=
510.76 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Attic, AH: Utility
b. Sup: Attic, Ret: Master Bedroom, AH: WIC 2
ft2
ft2
ft2
9.172 ft.
0.300
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2852.00 ft2
b. N/A R= ft2
c. N/A R= ft2
13. Cooling systems
a. Central Unit
b. Central Unit
14. Heating systems
a. Electric Strip Heat
b. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code com tture
Builder Signature: /"'.r Date:
Address of NeX ome.-7 848 (Werrt�GnY �Y1Gc l C�ty�FL Zip: 'P5L I FL 34 q
APR 0 8 1011
Permitting Dapartment
St. Lucie County
Area
2501.20 ft2
386.08 ft2
ft2
ft2
Area
2852.00 ft2
ft2
ft2
R ft2
6 85
6 40
kBtu/hr Efficiency
35.4 SEER:16.00
18.0 SEER:16.00
kBtu/hr Efficiency
27.0 COP:1.00
17.0 COP:1.00
Cap: 50 gallons
EF: 0.95
CF. Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/30/2021 9:53 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1 RECEIVED
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA APR 0 8 2021
Project Name: Jay Residence Builder Name: Permitting Dapartment
Street: 7848 Germany Canal Road Permit Office: St. Lucie County St. Lucie County
City, State, Zip: Fort Pierce , FL, 34987 Permit Number:
Y
U
Owner: Jay Residence Jurisdiction: St. Lucie County
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed eatth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
_e2daadJ&W=ipJng
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceelonas.
a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400.
3/30/2021 9:53 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
- FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performapampod
Project Name: Jay Residence
Builder Name:
APR ® 8 ZRI
Street: 7848 Germany Canal Road
Permit Office: St. Lucie County
Permitting Department
City, State, Zip: Fort Pierce , FL, 34987
Permit Number:
Lucie
St. Lucie County
Owner: Jay Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type42887.2 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2501.20 ft2
b. Interior Frame - Wood, Interior
R=13.0 386.08 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (2852.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2852.00 ft2
6. Conditioned floor area above grade (ft2) 2852
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(510.8 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Utility
R ft2
6 85
a. U-Factor: Sgl, U=0.65 510.76 ft2
b. Sup: Attic, Ret: Master Bedroom, AH: WIC 2 6 40
SHGC: SHGC=0.30
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.4 SEER:16.00
c. U-Factor: N/A ft2
b. Central Unit
18.0 SEER:16.00
SHGC:
Area Weighted Average Overhang Depth: 9.172 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.300
a. Electric Strip Heat
27.0 COP:1.00
b. Electric Strip Heat
17.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2852.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2852.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF, Pstat
Total Proposed Modified Loads: 84.99
Glass/Floor Area: 0.179
PASS
Total Baseline Loads: 86.19
I hereby certify that the plans and specifications covered by
Review of the plans and
Q 1114E STA
this calculation are in compliance with the Florida Energy
specifications covered by this
1+. Q
Code.
calculation indicates compliance
TOO
with the Florida Energy Code.
Before construction is completed
aV
PREPARE
DATE:
this building will be inspected for
compliance with Section 553.908
y.
w
I hereby certify that this building, as-cle&ign is ' mpliance
Florida Statutes.
y�
with the Florida Energy CodeObt5
OWNER/ `
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020
INPUT SUMMARY CHECKLI5T REPORT
PROJECT
Title:
Jay Residence
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2852
Lot #
Owner Name:
Jay Residence
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
7848 Germany Canal R
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34987
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Master
748
7352.2
2
Main Living
2104
19777.6
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
Bath 3
78
733.2 No
0
1
Yes
Yes
Yes
2
Bedroom 3
156
1466.4 No
1
1
1
Yes
Yes
Yes
3
Bedroom 2
176
1654.4 No
1
1
1
Yes
Yes
Yes
4
Hall
56
526.4 No
0
1
Yes
Yes
Yes
5
Closet 3
30
282 No
0
1
No
Yes
Yes
6
Closet 2
30
282 No
0
1
No
Yes
Yes
7
Bath 2
84
789.6 No
0
1
Yes
Yes
Yes
8
Utility
140
1316 No
0
1
Yes
Yes
Yes
9
Hall
52
488.8 No
0
1
Yes
Yes
Yes
10
Pantry
49
460.6 No
0
1
Yes
Yes
Yes
11
Den
155
1457 No
0
1
Yes
Yes
Yes
12
Foyer
78
733.2 No
0
1
Yes
Yes
Yes
13
Living Room
378
3553.2 No
2
1
Yes
Yes
Yes
14
Dining
154
1447.6 No
0
1
Yes
Yes
Yes
15
Kitchen
360
3384 Yes
2
1
Yes
Yes
Yes
16
Hall
128
1203.2 No
0
1
No
Yes
Yes
17
Master Bath
211
1983.4 No
2
1
Yes
Yes
Yes
18
Toilet
32
300.8 No
1
1
Yes
Yes
Yes
19
WIC 1
121
1137.4 No
1
1
Yes
Yes
Yes
20
Master Bedroom
321
3338.4 No
2
1
1
Yes
Yes
Yes
21
WIC 2
63
592.2 No
1
1
Yes
Yes
Yes
3/30/2021 9:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Bath 3
19 ft
78 ft2
----
1
0
0
2 Slab -On -Grade Edge Insulatio
Bedroom 3
12 ft
156 ft2
----
1
0
0
3 Slab -On -Grade Edge Insulatio
Bedroom 2
12 ft
176 ft2
----
1
0
0
4 Slab -On -Grade Edge Insulatio
Hall 2
4 ft
56 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulatio
Closet 3
1 ft
30 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulatio
Closet 2
1 ft
30 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulatio
Bath 2
6 ft
84 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulatio
Utility
27 ft
140 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulatio
Hall
4 ft
52 ft2
----
1
0
0
10SIab-On-Grade Edge Insulatio
Pantry
7 ft
49 ft2
----
1
0
0
11SIab-On-Grade Edge Insulatio
Den
23 ft
155 ft2
----
1
0
0
12SIab-On-Grade Edge Insulatio
Foyer
12 ft
78 ft2
__--
1
0
0
13SIab-On-Grade Edge Insulatio
Living Room
18 ft
378 ft2
----
1
0
0
14SIab-On-Grade Edge Insulatio
Dining
25 ft
154 ft2
----
1
0
0
15Slab-On-Grade Edge Insulatio
Kitchen
4 ft
360 ft2
----
1
0
0
16SIab-On-Grade Edge Insulatio
Hall 3
1 ft
128 ft2
----
1
0
0
17SIab-On-Grade Edge Insulatio
Master Bath
38 ft
211 ft2
----
1
0
0
18SIab-On-Grade Edge Insulatio
Toilet
4 ft
32 ft2
----
1
0
0
19SIab-On-Grade Edge Insulatio
WIC 1
11 ft
121 ft2
----
1
0
0
20SIab-On-Grade Edge Insulatio
Master Bedroom 34 ft
321 ft2
----
1
0
0
21SIab-On-Grade Edge Insulatio
WIC 2
2 ft
63 ft2
__--
1
0
0
ROOF
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 3302 ft2
0 ft2 Medium
N
0.6 No 0.9
No
20
30.26
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2852 ft2
N N
3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Bath 3
0
Blown
78 ft2
0.1
Wood
2
Under Attic (Unvented) Bedroom 3
0
Blown
156 ft2
0.1
Wood
3
Under Attic (Unvented) Bedroom 2
0
Blown
176 ft2
0.1
Wood
4
Under Attic (Unvented) Hall 2
0
Blown
56 ft2
0.1
Wood
5
Under Attic (Unvented) Closet 3
0
Blown
30 ft2
0.1
Wood
6
Under Attic (Unvented) Closet 2
0
Blown
30 ft2
0.1
Wood
7
Under Attic (Unvented) Bath 2
0
Blown
84 ft2
0.1
Wood
8
Under Attic (Unvented) Utility
0
Blown
140 ft2
0.1
Wood
9
Under Attic (Unvented) Hall
0
Blown
52 ft2
0.1
Wood
10
Under Attic (Unvented) Pantry
0
Blown
49 ft2
0.1
Wood
11
Under Attic (Unvented) Den
0
Blown
155 ft2
0.1
Wood
12
Under Attic (Unvented) Foyer
0
Blown
78 ft2
0.1
Wood
13
Under Attic (Unvented) Living Room
0
Blown
378 ft2
0.1
Wood
14
Under Attic (Unvented) Dining
0
Blown
154 ft2
0.1
Wood
15
Under Attic (Unvented) Kitchen
0
Blown
360 ft2
0.1
Wood
16
Under Attic (Unvented) Hall 3
0
Blown
128 ft2
0.1
Wood
17
Under Attic (Unvented) Master Bath
0
Blown
211 ft2
0.1
Wood
18
Under Attic (Unvented) Toilet
0
Blown
32 ft2
0.1
Wood
19
Under Attic (Unvented) WIC 1
0
Blown
121 ft2
0.1
Wood
20
Under Attic (Unvented) Master Bedroom 0
Blown
321 ft2
0.1
Wood
21
Under Attic (Unvented) WIC 2
0
Blown
63 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Belo
#
nrnt
Space
To Wall Type1
w
N
Exterior Concrete Block - Int Insul Bath 3
4.1
6
0 9
5
56.5 ft2
0
0
0.4
0
2
E
Exterior Concrete Block - Int Insul Bath 3
4.1
13
0 9
5
122.4 ft2
0
0
0.4
0
3
N
Exterior Concrete Block - Int InsuBedroom 3
4.1
12
0 9
5
113.0 ft2
0
0
0.4
0
4
N
Exterior Concrete Block - Int InsuBedroom 2
4.1
12
0 9
5
113.0 ft2
0
0
0.4
0
5
E
Exterior Concrete Block - Int Insul Hall 2
4.1
4
0 9
5
37.7 ft2
0
0
0.4
0
6
N
Exterior Concrete Block - Int Insul Bath 2
4.1
6
0 9
5
56.5 ft2
0
0
0.4
0
7
N
Exterior Concrete Block - Int Insul Utility
4.1
10
0 9
5
94.2 ft2
0
0
0.4
0
_ 8
S
Exterior Concrete Block - Int Insul Utility
4.1
3
0 9
5
28.3 ft2
0
0
0.4
0
9
W
Exterior Concrete Block - Int Insul Utility
4.1
14
0 9
5
131.8 ft2
0
0
0.4
0
10
W
Exterior Concrete Block - Int Insul Hall
4.1
4
0 9
5
37.7 ft2
0
0
0.4
0
11
W
Exterior Concrete Block - Int Insul Pantry
4.1
7
0 9
5
65.9 ft2
0
0
0.4
0
12
N
Exterior Concrete Block - Int Insul Den
4.1
6
0 9
5
56.5 ft2
0
0
0.4
0
13
S
Exterior Concrete Block - Int Insul Den
4.1
4
0 9
5
37.7 ft2
0
0
0.4
0
14
W
Exterior Concrete Block - Int Insul Den
4.1
13
0 9
5
122.4 ft2
0
0
0.4
0
15
E
Exterior Concrete Block - Int Insul Foyer
4.1
2
0 9
5
18.8 ft2
0
0
0.4
0
16
W
Exterior Concrete Block - Int Insul Foyer
4.1
10
0 9
5
94.2 ft2
0
0
0.4
0
17
S
WIC 2 Interior Frame - Wood Foyer
13
9
0 9
5
84.8 ft2
0
0.25
0.8
0
18
E
Exterior Concrete Block - Int Insdliving Room
4.1
18
0 9
5
169.5 ft2
0
0
0.4
0
19
W
Master B Interior Frame - Wood Living Room
13
3
0 9
5
28.3 ft2
0
0.25
0.8
0
3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
20
S
Master B
Interior Frame - Wood Living Room
13
21
0
9 5
197.8 ft2
0
0.25
0.8
0
_21
E
Exterior
Concrete Block - Int Insul Dining
4.1
14
0
9 5
131.8 ft2
0
0
0.4
0
_22
S
Exterior
Concrete Block - Int Insul Dining
4.1
11
0
9 5
103.6 ft2
0
0
0.4
0
23
E
Exterior
Concrete Block - Int Insul Kitchen
4.1
4
0
9 5
37.7 ft2
0
0
0.4
0
24
S
Master B
Interior Frame - Wood Hall 3
13
4
0
9 5
37.7 ft2
0
0.25
0.8
0
25
W
WIC 2
Interior Frame - Wood Hall 3
13
4
0
9 5
37.7 ft2
0
0.25
0.8
0
26
N
Exterior
Concrete Block - Int InsLMaster Bath
4.1
9
0
9 5
84.8 ft2
0
0
0.4
0
27
S
Exterior
Concrete Block - Int InsifUlaster Bath
4.1
9
0
9 5
84.8 ft2
0
0
0.4
0
28
W
Exterior
Concrete Block - Int InsUillaster Bath
4.1
20
0
9 5
188.3 ft2
0
0
0.4
0
29
S
Exterior
Concrete Block- Int Insul Toilet
4.1
4
0
9 5
37.7 ft2
0
0
0.4
0
30
S
Exterior
Concrete Block - Int Insul WIC 1
4.1
11
0
9 5
103.6 ft2
0
0
0.4
0
31
E
Exterior
Concrete Block - Int InsMaster Bedro
4.1
15
0
10 5
156.3 ft2
0
0
0.4
0
32
S
Exterior
Concrete Block - Int InsMaster Bedro
4.1
19
0
10 5
197.9 ft2
0
0
0.4
0
33
W
Exterior
Concrete Block- Int Insul WIC 2
4.1
2
0
9 5
18.8 ft2
0
0
0.4
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC LI-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl Low-E Single Yes
0.65
0.3
Y
5.8 ft2
1 ft 0 in
1 ft 4 in
None
None
2
N 3
Vinyl Low-E Single Yes
0.65
0.3
Y
17.5 ft2
1 ft 0 in
1 ft 4 in
None
None
3
N 4
Vinyl Low-E Single Yes
0.65
0.3
Y
17.5 ft2
1 ft 0 in
1 ft 4 in
None
None
4
E 5
Vinyl Low-E Single Yes
0.65
0.3
Y
22.7 ft2
2 ft 0 in
1 ft 4 in
None
None
5
N 6
Vinyl Low-E Single Yes
0.65
0.3
Y
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
6
N 7
Vinyl Low-E Single Yes
0.65
0.3
Y
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
W 9
Vinyl Low-E Single Yes
0.65
0.3
Y
18.7 ft2
1 ft 0 in
1 ft 4 in
None
None
8
W 10
Vinyl Low-E Single Yes
0.65
0.3
Y
10.0 ft2
1 ft 0 in
1 ft 4 in
None
None
9
W 11
Vinyl Low-E Single Yes
0.65
0.3
Y
10.0 ft2
1 ft 0 in
1 ft 4 in
None
'None
10
W 14
Vinyl Low-E Single Yes
0.65
0.3
Y
30.0 ft2
1 ft 0 in
1 ft 4 in
None
None
11
W 16
Vinyl Low-E Single Yes
0.65
0.3
Y
41.0 ft2
14 ft 0 in
1 ft 4 in
None
None
12
E 18
Vinyl Low-E Single Yes
0.65
0.3
Y
128.0 ft2
18 ft 0 in
1 ft 4 in
None
None
13
E 21
Vinyl Low-E Single Yes
0.65
0.3
Y
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
14
S 22
Vinyl Low-E Single Yes
0.65
0.3
Y
41.0 ft2
12 ft 0 in
1 ft 4 in
None
None
15
W 28
Vinyl Low-E Single Yes
0.65
0.3
Y
18.7 ft2
1 ft 0 in
1 ft 4 in
None
None
16
S 29
Vinyl Low-E Single Yes
0.65
0.3
Y
4.0 ft2
1 ft 0 in
1 ft 4 in
None
None
17
S 30
Vinyl Low-E Single Yes
0.65
0.3
Y
8.0 ft2
1 ft 0 in
1 ft 4 in
None
None
18
E 31
Vinyl Low-E Single Yes
0.65
0.3
Y
40.4 ft2
18 ft 0 in
1 ft 4 in
None
None
19
S 32
Vinyl Low-E Single Yes
0.65
0.3
Y
27.5 ft2
1 ft 0 in
1 ft 4 in
None
None
3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000362
2713 148.84 279.43 .1161
6
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COP:1 27 kBtu/hr
COP:1 17 kBtu/hr
2
1
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Singl SEER: 16 35.4 kBtu/hr cfm
Sing[ SEER: 16 18 kBtu/hr cfm
0.7 2
0.7 1
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Utility
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
V/ #
-Supply ----
Location R-Value Area
---- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
2
Attic 6 85 ft2
Attic 6 40 ft2
Attic 20 ft2 Prop. Leak Free Utility --- cfm 63.1 cfm 0.03 0.50
Master Bedro 5 ft2 Prop. Leak Free WIC 2 --- cfm 22.4 cfm , 0.03 0.50
1 1
2 2
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
Heatinf X� Jan f X� Feb Mar
Ventin [ Jan [ Feb X Mar
Ceiling Fans:
Apr Ma rj Jun X Jul X Au Se
Apr IMayJun I Jul IAu�XjSeP f
A r May Jun JUI Aug Se [X
Oct Nov
Oct Nov
Oct HNov
Dec
XDec
[ Dec
3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Bath 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Closet 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Closet 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
utility
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Den
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Defauk(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Toilet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
3/30/2021 9:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7