Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Design Pressure Report (Butler) - Master Craft Aluminum Products
Property Information Owner:Butler Address:6594 Dulce Real Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 53 62 7 37.3 -40.6 2 Int 37 62 7 38.2 -41.5 3 Int 53 55 7 37.6 -40.9 4 Int 53 55 7 37.6 -40.9 5 Int 74 62 7 36.4 -39.8 6 Int 26 38 7 39.4 -42.7 7 Int 26 38 7 39.4 -42.7 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1