HomeMy WebLinkAboutFire Protection PlanZ 16X16 0 KITCHEN J Q BALCONY { I I I 16XI6 Sprinkler Head Schedule Symbol Count Thread K-Factor Description Note 2 1/2" 5.8 TY3934 1/2 FIR 175 WP FOR ON DROP 19 1/2" 5.8 TY3934 1/2 FIR 155 WP FOR ON DROP 4 19 1/2" 5.8 TY4334 1/2 FIR 155 WP HSWR 40 - Total Number of Heads This Floor L _-'__ _L I__ LIVING 11 I \ BREAKFAST !( _ L. _ 8'-3" CLG. HGT. L € 101 1� f BEDROOM #2#2 8'-3" CLG. HOT. o to Q BALCONY OFFICE TABLE 8.6.5.1.2 POSITIONING OF SPRINKLERS TO AVOID OBSTRUCTIONS TO DISCHARGE SSU%SSP MAIOMUM ALLOWABLE DISTANCE DMANCE FROM SIMLERS OF DDUCTOR A X BOITOM TO SIDE OF OBSIRDICIION 0) OF OBSTRUCTS (B) DIN.) LESS THAN 1 Fr 0 1 Fr TO LESS THEW I Fr 6 IN. 2h 1 Fr 6 IN, TO LESS THAN 2 Fr 3K 2 FT TO LESS THAN 2 FT 6 IN. 51F 2 Fr 6 IN. TO LESS THAN 3 IT A4 3 Fr TO LESS THAN 3 FT 6 IN. 91F 3 FT 6 IN. TO LESS THAN 4 IT 12 4 FT TO LESS THAN 4 FT 6 IN. 14 4 FT 6 IN. TO LESS THAN 5 Fr 164 5 FT TO LESS THAN 5 R 6 IN. 18 5 FT 6 IN. TO LESS IN 6 IT 20 6 FF TO LESS TIM 6 Fr 6 N. 24 6 FT 6 IN. TO LESS THAN 7 Fr 30 7 FT TO LESS RAN 7 IT 6 IN. 35 NOTE FOR A AND B, REFER TO FIGURE 8.6.512 (a) Funk tu.b.1.2 (a) PO MME OF Smillio TO A19b FXXIRE A.8.5.5.1 OBSTRIVIONS TO SPRINIILER DISGAROE OBSTBL1CTION TO DEEM (SSU%SSP). PAIIFRN DMWM09 FOR STANDARD LMff IR PENDENT SPRAY SSPoNI(IERS. HANGER SPACING REQUIREMENTS 9.2.2.1 The maximum distance between hangers shall not exceed that specified in'Table 9.2.2.1(a) or Table 9.2.2.l(b), except where the provisions of 9 2.4 apply. TABLE 9.2.2.1(a) MAXIMUM DISTANCE BETWEEN HANGERS (ft—in.) NOMINAL PIPE SIZE (in.) 1 1 X 1 %z 2 2,1z 3 3,1,� 4 5 6 8 STEEL PIPE EXCEPT THREADED LIGHTWALL N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED UGHTWALL STEEL PIPE N/A 12-0 12-0 12-0 12-0 12-0 12-0 N/A. N/A N/A N/A N/A COPPER TUBE 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 15-0 15-0 CPVC 5-6 6-0 6-6. 7-0 8-0 9:-0 10-0 N/A N/A N/A N/A N/A POLYBUTYLENE (IPS) N/A 3-9 1 4-7 5-0 5-11 N/A N/A N/A N/A N/A N/A N/A POLYBUIYLENE (CTS) 2-11 3-4 3-71 4-S 5-5 N/A N/A N/A N/A N/A N/A N/A DUCTILE IRON PIPE N/A N/A' N/A N/A N/A I N/A 1 15-0 N/A 15-0 N/A 15-0 15-0 NOTE: IPS IRON - PIPE SIZE; CTS - COPPER TUBE SIZE a Q. J _ *� o < N W o V U O 0 i E CD- a H [VI W � 21 � Q e ) * U°D ID ZLLLL N �ik c LU N a a y V a O N J W Y G U 8'-3",CLG. HOT. 2 Ul n w Q 6' fn c GENERAL NOT O: o _ -� _ al 1. ALL PIPING, HANGERS, SUPPORT METHODS AND SPRINKLER U- `O HEADS TO BE INSTALLED IN STRICT ACCORDANCE WITH NFPA 13, U. 2016 EDITION AND ALL LOCAL CODES AND ORDINANCES. U o 2. SPARE SPRINKLER HEADS AND WRENCHES SHALL BE PROVIDED > M o 0 IN ACCORDANCE WITH NFPA 13, 2016 EDITION. hr C 2 -a CU N N 3. TEMPERATURE CLASSIFICATION FOR SPRINKLER HEADS SHALL N CO M d : N INBE ORDINARY UNLESS NOTED OTHERWISE.13 3:1L ni N 4. ALL THREADED PIPING ABOVEGROUND THAT SHALL BELL ~ r r to X FAMILY ROOM SCHEDULE 40. ALL ROLL -GROOVED PIPING ABOVEGROUND SHALL t r E 8'-3" CLG. HOT. I BE SCHEDULE 10. ALL FITTINGS SHALL BE GROOVED OR DUCTILE M Li 1 IRON THREADED. 5. PRESSURE TEST AND FLUSH THE SYSTEM IN ACCORDANCE WITH THIS DRAWING AND ITS CONTENTS ARE THE PROERTY OF ADT NFPA 13, 2016 EDITION REQUIREMENTS. COMMERCALL.IITI NOTTOBE 6. PROVIDE FLUSHING CONNECTIONS AS REQUIRED. REMOVABLE USED OR DUPLICATED BY ANYONE WITHOUT THE WRITTEN CONSENT 16X20 FITTINGS SHALL BE PROVIDE Al- END OF CROSSMAINS. OF ADT COMMERCIAL. 7. SPRINKLER HEADS SHALL BE AUTOMATIC, CAST BRASS CLOSED IF ANY DOCUMENT PREPARED BY ADT COMMERCIAL IS ALTERED IN ANY MANNER v BALCONY FUSIBLE LINK OR GLASS BULB TYPE, ORDINARY TEMPERATURE BY OWNER, ITS CONSTRUCTION NI BY ANY THIRD PARK IF CONSTRUCTION IS NOT IN ACCORDANCE WITH UNALTERE U RATING UNLESS NOTED OTHERWISE, CONFIGURATION AS NOTED DOCUMENTS PREPARED BY ADT ON DRAWINGS. FACTORY COATING OR. FINISH SHALL BE AS NOTED THAMERCIAL THEN ITAUNDERSTOOD ACTCOMMERC1LHASNO LIABILITY IN OR IN PART, RELATED TO THE 12X12 / ON SPRINKLER HEAD SCHEDULE. INSTALLATION SHALL BE IN PRO ELT AND THAT THE OWNER AND ITS AGENTS INDEMNIFY AND HOLDS ACCORDANCE WITH NFPA 13, 2016 EDITION AND IN ACCORDANCE HARMLESS ADT COMMERCIAL FOR ANY - 12X12AND ALL WITH MANUFACTURER'S INSTRUCTIONS, THIS CONCEPT CDRAWING IS FOR INFORMATION ONLY TO POTENTIAL ` " 1 8.IDENTIFICATION FOR ALL PIPING, VALVE, ETC SHALL BE PROVIDED SYSTEM ARRANGEMENT. CONTRACTOR SHALL FIELD VERIFY ALL INFORMATION CONTAINED ON THESE DRAWINGS AND IS SCOPE OF WORK. RESPONSIBLE OF THES SYSTEM AND $- C C SCOPE GG C WORK: INSTALLATION OFT HE SYSTEM IN GT. ACCORDANCE WITH THE SPECIFICATIONS. ADTC SCOPE CONSISTS OF REMOVING AND REPLACING ALL CPVC PIPE IN RESIDENCE TO THE BEST OF ADT COMMERCIAL'S UNIT. REPLACING SPRINKLER HEADS TO MEET COVERAGE PER NFPA 13. KNOWLEDGE THE DRAWINGS AND SPECIFICATIONS SUBMITTED HEREWITH, D ".� COMPLY WITH EXISTING SHEET INDEX. INTERPRETATIONS AND PREVISIONS OF THE APPLICABLE N F.P.A. CODES IN EFFECT AT DATE SHOWN. 1� FP-1 GENERAL NOTES, DETAILS AND FIRE SPRINKLER PLAN MASTER SUITE IU20 8'-3" CLG. HOT. DESIGN CRITERIA: Z V) HAZARD: W RESIDENTIAL .I W LIGHT HAZARD 0.10gpm / 4 MOST DEMANDING HEADS V Lrn OUTMAXI MUM SPACING DE HOSE: UM 9 OOsgft MINUTE DURATION W C> m SPARE HEAD BUx. z® W L,_ I I GI W af V N.F.P.A 13, 6.2.9.5 \ THE STOCK OF SPARE SPRINKLERS SHALL INCLUDE ALL TYPES AND RATINGS W .--J 0C Q LU INSTALLED AND SHALL BE AS FOLLOWS: F— (/) to CO 1" X ARMOVER 1 " 90 EL. (1) FOR PROTECTED FACILITIES HAVING UNDER 300 SPRINKLERS - NO FEWER ® CD Z c9 THAN 6 SPRINKLERS 11 w TYPICAL TYPICAL00 J z CONCRETE 6.2.9.6 ONE SPRINKLER WRENCH AS SPECIFIED BY THE SPRINKLER v O Z DECK MANUFACTURER SHALL BE PROVIDED IN THE CABINET FOR EACH TYPE OF W z r n w SPRINKLER INSTALLED TO BE USED FOR THE REMOVAL AND INSTALLATION OF 4J l�D .M \ter J1 ^t'.j,;'1 �'.`,X1'�'a' '^' •: i t tj W SPRINKLERS IN THE SYSTEM. 1 ' X DROP r TYPICAL �^ ...=.. LJ- W HANGER SUPPORT: clC CONCRETE INSERT PER NFPA 13, 9.2.3.5.1: JURISDICTION: SIC. FR THE CUMULATIVE HORIZONTAL LENGTH OF AN UNSUPPORTED ARMOVER TO �If31CL:flPRINKLER, SPRINKLER DROP, OR SPRIG SHALL NOT EXCEED 24 IN. FOR FIRE PROTECTION PLAN UNIT A 11TH FNGER ROD DIAMETER DESIGNED BY: STEEL PIPE OR 12 IN FOR COPPER TUBE FLOOR 1" THRU 4" PIPE DATE: p312.2021 TYPICAL 1 TYPICAL R.C..C. } - 6" THRU 8 PIPE PER NFPA 13 9.2.3.5 a 1 SCALE: Yq a ) 1-� a WHERE THE MAXIMUM STATIC OR FLOWING PRESSURE, WHICHEVER IS PROJECT NO: 280607287 - GREATER AT THE SPRINKLER, APPLIED OTHER THAN THROUGH THE FIRE S IVEL RING DEPARTMENT CONNECTION, EXCEEDS 100 psi AND A BRANCH LINE ABOVE A CEILING SUPPLIES SPRINKLERS IN A PENDENT POSITION BELOW THE SCALE: a' = V-0" 0 2' 41 81 CEILING, THE CUMULATIVE HORIZONTAL LENGTH OF AN UNSUPPORTED ARMOVER TO A SPRINkLER OR SPRINKLER DROP SHALL NOT EXCEED 12 IN. TITLE: INTH[ AI BCAI DETAIL HANGER num 41 FOR STEEL PIPE ANA9IN. FOR COPPER TUBE . SHEET TITLE 1 Scale: t 4 = 1'-0" I`LIIIJJ�I\\�IVV ULL�IVV SHEET TITLE 2 SHEET: FID-1