HomeMy WebLinkAboutHVAC PlanW ■ ■ Digitally signed by ` '� ° ► Thomas V Platania ..n the missing piece CAC181_a254 ProCalcs, LLC Date: 2021.02.03 13:42:05-05i00i Signature can only be verified and validated with electronic copy of documents. Amok vii"a t -�- maw Please note not all notes may apply. 1. CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM. ARE NOTED ON THE MECHANICAL PLANS. 2. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. CAREFUL ATTENTION SHALL BE PAID TO PRECISE LOCATION AND 15. FOR EACH RETURN AIR GRILLE, PROVIDE 3M FILTRETE 1000 MICRO ALLERGEN PLEATED AIR FILTERS (3M, 800-49403552, COORDINATION OF DIFFUSERS, REGISTERS, AND GRILLES WITH STRUCTURAL FRAMING AND ELECTRICAL FIXTURES AT www.filtrete.com, MERV RATING: 11, PRESSURE DROP:.2 @ 300 FPM, OR APPROVED SUBSTITUTE). PRIOR TO INSTALLATION, CEILING LOCATIONS. ELECTRICAL FIXTURES AT CEILING TAKE PRIORITY OVER DUCT LAYOUT. ELECTRICAL FIXTURES AT THE CONTRACTOR SHALL VERIFY THAT THE AIR VELOCITY NOICE ACROSS EACH RETURN AIR FILTER WILL BE LOW, BASED CEILING ARE NOT 0 BE MOVED FROM THEIR PROPOSED LOCATIONS. SEE THE REFLECTED CEILING PLANS, WHERE ON THE PRESSURE DROP FOR PROPOSED FILL ER TYPE AND THE PROPOSED RETURN AIR GRILLE SIZE(S). ANY RETURN AIR AVAILABLE, FOR EXACT LOCATIONS OF CEILING FIXTURES. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT PERMISSION FILTER GRILLES THAT ARE REQUIRED TO BE RFSIZED BY THE CONTRACTOR, ARE TO BE SIZED FOR FILTER SIZES THAT ARE FROM STRUCTURAL ENGINEER. READILY AVAILABLE AT HOME SUPPLY STORES. CUSTOM SIZES ARE NOT PERMITTED. 3. THE CONTRACTOR SHALL OBTAIN, AT HIS EXPENSE, ALL NECESSARY FEES, P RMITS, AND TESTS. 16. ALL BATH, KITCHEN, AND DRYER EXHAUST(S) SHALL BE VENTED TO THE EXTERIOR. 4. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS, ORDINAI 4CES AND REQUIREMENTS OF AUTHORITIES 17. ALL BATH EXHAUST FANS SHALL BE DUCTED WITH 4" R-FIN. SLOPE AND FULLY SUPPORT ALL BATHROOM EXHAUST DUCTS HAVING JURISDICTION. NO CONTRACTOR SHALL BID UNLESS FAMILIAR WITH HESE CODES. ALL WORK SHALL BE TO AVOID ANY SNAGS IN THE DUCT AND TO ALLOW FOR PROPER DRAINAGE. TERMINATE AT SOFFIT WITH SCREENED EXECUTED IN A WORKMANLIKE MANNER AND SHALL PRESENT A NEAT, PROF SSIONAL APPEARANCE WHEN COMPLETED. GRILLE, UNLESS OTHERWISE NOTED. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. STORE AND INSTALL MATERIALS AND EQUIPMENT IN ACCORDANCE WITH 18. PROVIDE BACKDRAFT DAMPERS FOR ALL EXHAUST FANS. THE MANUFACTURER'S INSTRUCTIONS. 19. ALL EXHAUST AIR DUCTS SHALL BE GALVANIZED SHEET METAL CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE HVAC SYSTEM(S) TO BE INSTALLED (REFRIGERANT LINES, EQUIPMENT, ASHRAE AND SMACNA STANDARDS.D DUCTWORK, GRILLES, ETC.). ADDITIONAL OFFSETS, TRANSITIONS, ETC. MAY E REQUIRED TO PROVIDE A COMPLETE 20. TESTING, ADJUSTING, AND BALANCING: THE CONTRACTOR SHALL BALANCE THE AIRFLOW DISTRIBUTION SYSTEMS, SYSTEM. NO ABRUPT TRANSITIONS SHALL BE PERMITTED. THE MECHANICAL WORK HEREIN INCLUDES COMPLETE INCLUDING SUB MAINS, BRANCHES, AND TERMINALS TO QUANTITIES INDICATED ON THE UPDATED MANUAL J LOAD SYSTEMS OF HEATING, AIR CONDITIONING (TEMPERATURE AND HUMIDITY CONTROL), VENTILATION, BATHROOM EXHAUST, ANALYSIS (FOR RESIDENTIAL PROPERTIES) AND MANUAL J (COMMERCIAL PROPERTIES). KITCHEN EXHAUST, AND ALL DUCTWORK. THE CONTRACTOR SHALL PROVIDE EACH ELEMENT THEREOF, AS INDICATED 21. PROVIDE DRAW -THROUGH CONDENSATE TRAP AT EACH UNIT CONDENSATE DRAIN. DEPTH SHALL BE AT LEAST 1-1/2 TIMES HEREIN, OR REASONABLY INFERRED (WHETHER OR NOT SPECIFICALLY CALLED FOR BY ITEM), REASONABLY NECESSARY TO THE TOTAL S.P DROP OF THE UNIT. FACILITATE EACH SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND EQUIPMENT SPECIFIED. CONTRACTOR SHALL 22. PROVIDE PROGRAMMABLE SERIES 7-DAY THERMOSTAT, PRIOR TO ORDERING THE THERMOSTAT, THE CONTRACTOR SHALL VERIFY SPACE CONDITIONS PRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK. VERIFY THAT THE SPECIFIED THERMOSTAT WILL OPERATE PROPERLY WITH THE PROPOSED AIR CONDITIONING EQUIPMENT. 6. THE CONDENSING UNIT AND AIR HANDLING UNIT EQUIPMENT SHALL BE AS SPECIFIED OR ARCHITECT APPROVED IF A SUBSTITUTE IS REQUIRED, CONTRACTOR MUST SUBMIT PRODUCT INFORMATION TO ARCHITECT FOR PRODUCT SUBSTITUTE. APPROVAL. COORDINATE THERMOSTAT LOCATION WITH FURNITURE/EQUIPMENT LAYOUTS, WINDOWS AND DOOR SWINGS. 7. PRIOR TO START OF THE HVAC WORK, THE CONTRACTOR SHALL SUBMIT, TO THE ARCHITECT, AN UPDATED MANUAL J LOAD THERMOSTAT MUST BE LOCATED AT 54" A.F.F. AND NOT LOCATED ON AN OUTSIDE WALL. ANALYSIS, BASED ON THE FINAL CONTRACTOR DOCUMENTS AND ACTUAL MATERIALS AND PRODUCTS SELECTED (ie: 23. SUPPLY AND RETURN AIR GRILLES SHALL MAINTAIN A MINIMUM DISTANCE OF 3'-01, FROM CEILINGS FANS. BUILDING ENVELOPE INSULATION, EXTERIOR DOOR GLAZING, AND ANY OTHE APPLICABLE FACTORS THAT WOULD AFFECT 24. ALL DUCT BRANCHES, PER ACCA MANUAL D, SHOULD INCLUDE DAMPERS FOR PROPER AIR FLOW AND BALANCING. THE UPDATED MANUAL J LOAD ANALYSIS). THE SIZING OF THE ACTUAL HVAC SYSTEMS TO BE UTILIZED (REFRIGERANT 25. NO EQUIPMENT SHALL BE PURCHASED UNTIL REVIEW BY THE PROFESSIONAL OF RECORD, EVEN IF EQUIPMENT HAS BEEN LINES, EQUIPMENT, DUCTWORK, GRILLES, ETC.) SHALL BE BASED ON THE UPDATED MANUAL J LOAD ANALYSIS. THE SPECIFIED. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR PROPERLY SIZING THE HVAC SYSTEM. 26. ANY VARIATION FROM THE DESIGN PRESENTED COULD AFFECT SYSTEM PERFORMANCE. 8. THE CONTRACTOR SHALL COORDINATE A "MECHANICAL WALK-THROUGH" MEETING, WHICH IS TO OCCUR PRIOR TO THE 27, EQUIPMENT SHALL BEAR A U.L. OR OTHER RECOGNIZED LABEL, NAMEPLATES, WIRING DIAGRAMS, AND ENERGY RATINGS, START OF THE MECHANICAL ROUGH -IN. THE PURPOSE FOR THIS MEETING IS TO ALLOW THE OWNER, ARCHITECT, AND AS APPLICABLE. CONTRACTOR TO REVIEW AND COORDINATE FINAL DUCT AND AIR DEVICE LOCATIONS. THE MECHANICAL 28. CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND ACCESSORIES SO THAT IT IS READILY ACCESSIBLE FOR SERVICING, SUBCONTRACTOR'S FOREMAN IS TO ATTEND THIS MEETING AS WELL. TESTING, BALANCING AND REPLACEMENT. 9. NO CHANGES TO THE HVAC PLANS OR NOTES SHALL BE PERMITTED WITHOUI PROCALCS, LLC. PRIOR APPROVAL. 29. CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE AGAINST DEFECTS INALL MATERIALS AND WORKMANSHIP FOR ONE 10. REFRIGERANT PIPING SHALL BE TYPE "L" SOFT DRAWN COPPER, ASTM B280,AND SHALL BE MILL CLEANED, DRIED AND (1) YEAR FROM ACCEPTANCE WITH FOUR ADDITIONAL YEARS OF WARRANTY ON COMPRESSORS. CAPPED. INSULATE REFRIGERANT SUCTION LINE WITH " WALL FOAMED PLAS IC INSULATION SLIPPED OVER TUBING AND 30. PRIOR TO ACCEPTANCE BY THE OWNER, THE SYSTEMS SHALL BE TESTED AND BALANCED BY A AABC OR NEBB CERTIFIED ALL JOINTS THOROUGHLY SEALED. PAINT REFRIGERANT PIPING INSULATION VMTH TWO (2) COATS OF ACRYLIC PROTECTIVE T&B CONTRACTOR EXPERIENCED WITH THIS SYSTEM. THE CONTRACTOR SHALL CERTIFY THE TESTING AND BALANCING PAINT WHERE INSULATION IS EXPOSED TO WEATHER. WITHIN +/- 10% OF DESIGN CFMS AND PROVIDE BALANCE TEST SHEETS. 11. ALL FIBERGLASS DUCTWORK SHALL BE 1-1/2" FIBROUS GLASS ANTI -MICROBIAL DUCTBOARD INSTALLED IN ACCORDANCE 31. AIR BALANCE TO BE PERFORMED BY THE AIR CONDITIONING CONTRACTOR TO THE OWNER'S COMFORT. ALL SUPPLY AND WITH THE LATEST EDITION OF S.M.A.C.N.A. FIBROUS GLASS DUCT CONSTRUCTION STANDARDS. 1" FIBROUS GLASS RETURN DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS AND LOCAL BUILDING CODES. ANTI -MICROBIAL DUCTBOARD MAY BE USED IN THOSE LOCATIONS WHERE ALLOWED BY CODE. NO ABRUPT TRANSITIONS 32. PROVIDE ALL CONTROLS, STARTERS, CONTROL WIRING, DISCONNECTS, AND OTHER ELECTRICAL EQUIPMENT AS REQUIRED SHALL BE PERMITTED. PROVIDE AIR TURNING VEINS IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS. FOR A COMPLETE AND OPERATIONAL SYSTEM. MECHANICAL CONTRACTOR IS TO COORDINATE WITH OTHER 12. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M-KA TYPE WITH 1-112" ONE -POUND DENSITY INSULATION AND VINYL VAPOR CONTRACTORS TO ENSURE THAT ALL ITEMS REQUIRED ARE INCLUDED IN BARRIER OR ARCHITECT APPROVED SUBSTITUTE. NO ABRUPT TRANSITIONS HALL BE PERMITTED. 33. COORDINATE ALL POWER AND CONTROL WIRING WITH ELECTRICIAN. 13. DUCT SIZES SHOWN ARE INSIDE NET DIMENSIONS. 1 14. ALL AIR DEVICES SHALL BE MANUFACTURED BY TITUS, 250 SERIES, OR APPROVED SUBSTITUTE. COLOR TO BE APPROVED BY THE PROFESSIONAL OF RECORD PRIOR TO PAINTING GRILLES BUT ASSUMED TO BE WHITE FOR BID/BUDGET PURPOSES. SUPPLY AIR REGISTERS SHALL BE DOUBLE DEFLECTION TYPE WITH OPPOSED BLADE DAMPERS. ALL :;IZES AND PATTERNS 0 'We are the missing piece' PO Box 882032 Port Saint Lucie, FL 34988 Phone: 772-882-5700 www.ProCalcs.Net tom@procalcs.net License CAC1815254 i ■ i + 1 No. Revision/Issue =Date 1 Issue /3/2021 For: Cooke Construction, Inc 1276 NE Business Park PL, Jensen Beach, FL 34957 Drawn By: Sheet ZWM Checked By: TP Date: 2/3/2021 Scale: As Shown CN lol LJ CONDENSING UNIT BOLTED TO CONCRETE PAD TO WITHSTAND HURRICANE FORCE WINDS. AS PER FBCM 301.12 COND. UNIT ISOMODE a n 4" CONC. PAD ` 4" CONCRETE SLAB. TOP OF SLAB. PAD (TYPICAL) NOTE: CONDENSING UNITS TO BE INSTALLED ABOVE FLOOD LEVEL CRITERIA. CONDENSING UNIT MOUNTING DETAIL 1 1/2' MIN. —� 5TRAP HANGER FLEXIBLE DUCT SAG NOT TO EXCEED 1/2' PER FOOT MAX=--�, 16 GA. HURRICANE \ STRAP 1/4" X 2" SELF -DRILLING \ SHEET METAL SCREW 3/8" X 2 112" QUICK -BOLT EXPANSION ANCHOR. (TYPICAL OF 4 ONE PER CORNER OF UNIT) n � / NOTES: 1. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP. 2. PITCH DRAIN FOR PROPER RUNOFF. 3. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM INITIAL DRAIN SEAL. 4. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. THIS STANDARD DETAIL MUST BE REVIEWED AND SITE ADAPTED BY CONTRACTOR PRIOR TO USE FOR FINAL EQUIPMENT. A/C UNIT CLEANOUT (TYPICAL) PITCH ? DRAIN PAN —' DRAIN PIPE TO MATCH DRAIN OUTLET SIZE. PITCH (a) THIS DIMENSION IN INCHES MUST BE EQUAL TO THE MAXIMUM FAN SUCTION (NEGATIVE) STATIC PRESSURE IN INCHES WC (WITH DIRTY FILTERS, COILS, AND MAXIMUM AIR FLOW) + 1" W.C. (b) THIS DIMENSION IN INCHES MUST BE EQUAL TO MIN, 1/2 OF THE (a) ABOVE. (c) EQUAL (a) + (b) + PIPE CIA. + INSULATION. (d) TRAP SEAL SHALL BE 2" MIN. ON UNITS LARGER THAN 3 TONS SHALL BE 3" MIN. PER F.B.C.-4606.7 WHERE APPLICABLE. (e) TRAP SEAL SHALL BE 2" MIN. TO 4" MAX. PER S.B.C.C.I.-1002.4 WHERE APPLICABLE. VENT LINE PERFORATED CAP. 1/2" ABOVE BOTTOM OF DRAIN PAN NTS DRAW THROUGH UNIT CONDENSATE TRAP HANGER (TYPJ 2' MIN. SUPPORT STRAP 118" MAX. FROM DEVICE AND 5'-0" ON CENTER WALL NTS FLEX HEATER SECTION * RETURN AIR BROUGHT IN THROUGH SEALED PLENUM. DUCT ) i MAXIMUM ALLOWABLE AIR LENGTH OF FLEX. DUCT HANDLING 8'-01 UNIT * PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO THE UNIT & FILTER CAN BE — — — — FLEX DUCT ACCOMPLISHED. FASTENERS MAY BE OMITTED IF HANGER LOOPS UNDER DUCT. 20 GAUGE GALVANIZED DROP PAN FASTENS MAINTAIN RADIUS OF BEND AIR UNDER ENTIRE UNIT W/ MOISTURE RETURN TO NOT LE55 THAN ONS DUCT DIAMETELGi DUCT PLENUM BOX FL RIND RECTANGULAR DUCT OOR DUCTWORK SUPPORT DETAILS NTS VERTICAL AHU DETAIL NTS NOTEPROVIDE CABLE CONTROL DAMPER FOR HARD CEILING AREAS LOCKING QUADRANT GALV. STEEL ROD OR TO BE EXPOSED STRAP SUPPORTS PER SMACNASTANDARDS FLEXIBLE DUCT WITH SIDE TAKE -OFF FITTING INSULATION & WITH DAMPER, BELL MOUTH VAPOR BARRIER OR SHOETAP TYPE (SEE NOTE) MAIN SUPPLY AIR TIE TO DUCT, SEE PLANS FOR STRUCTURAL TYPEANDI SULATION TURNING VANES MAIN TRUNK DUCT SUPPORTS WITH SHEET METAL — — SCREW FASTENERS / �I 2" WIDE METAL BAND ` \ ' ' ( Jy45° FLAREDJAP PROVIDE CLASS 1 FLEX i ` v SUPPORT INTO TRUNK D CT DUCT TO DIFFUSERS / L_ 1-1/2" X 1-1/2" X 118" GALV. C t SQUARE TO ANGLE OR STRAP PER SMACNA (((( rr ROUND I CONNECT INNER DUCT WITH DRAWBAND /lJ CIRCULAR DUC FOR CONNECTION ADAPTER AND SEAL WITH TAPE/MASTIC OUTERDUCT AIR FLOW AT NECK CONNECTION LINEAR DIFFUSER TO FLEX DUCT SSS PLENUM BOX PROVIDE THERMAL INSULATION BLANKET LINEAR DIFFUSER IF INSTALLED IN UNCONDITIONED SPACE CEILING SUSPENDED TYPE LOUVERED FACE CEILING DIFFUSER CEILING SYSTEM TYPICAL DIFFUSER DETAIL NTS LINEAR DIFFUSER DETAIL NTS Signature can only be verified and validated with electronic copy of documents. EQUIPMENT SCHEDULE CU NUMBER CU-1 CU-2 NOMINAL TONNAGE 4 ton(s) 2.5 ton(s) H MODEL 4A7L6048A1 4A7L6030A1 z SEER/EER 15.30/13.00 15.50/13.00 O CAPACITY TOTAL/SENS. 43824/36582 27004/23057 Z STAGES Single Single H RLA - LRA 18.5 - 124 12.8 - 67.8 W G Z O Voltage Phase MCA/MOP 208/230 1XI 4601 208/230 1XI 460 Single 1XI Three I I Single 1XI Three 24/40 17/25 V WEIGHT 216 160 AHU NUMBER AHU-1 AHU-2 AHU-MODEL TEM6AOD48H41++TDR TEM6AOB3OH21++TDR STATIC PRESSURE 0.60 0.60 REFRIGERANT R-41 OA R-41 OA LOCATION Mech Closet Mech Closet CFM 1567 967 FAN MOTOR HP - FLA 3/4 - 6.8 1/3 - 2.8 W J ELECTRIC HEATER Voltage Phase kW Model Number MCA/MOP 208 1XI 230 1XI 4601 208 1XI 230 460 Single 1XI Three I I Single 1XI Three 5.76 (208V) - 7,68 (240V) 3.60 (208V) - 4.80 (240V) BAYHTR1508BRKC BAYHTR1505BRKC 43/45 208V - 49/50 240V 25/25 208V - 29/30 230V Z DIMENSIONS H x W x D 55-3/4 x 23-1/2 x 21-1/8 46-3/4 x 18-1/2 x 21-1/8 a WEIGHT 174 117 REF LINES SIZES 7/8, 3/8 3/4, 3/8 a NOTES: American Standard AHRI #: 10299034 AHRI #: 10225066 GRILLE SCHEDULE Titus Series 250 Size Velocity (FPM) 400 500 8 x 4 CFM 65 80 Throw (ft) 4-way 3-way 2-way 1-way 12 14 13 15 14 17 117 21 GRILLE SCHEDULE Titus Series FL Linear SDL-1 2 x 1" Slot CFM/ft 50 75 Throw (ft) 20 25 SDL-2 2 x 1.5" Slot CFM/ft 60 85 Throw (ft) 22 27 TT 'c ® 'We are the missing piece' PO Box 882032 Port Saint Lucie, FL 34988 Phone: 772-882-5700 www.ProCalcs.Net tom@procalcs.net License CAC1815254 `'I o Cl� O Mll � � � U O 4-1 U O V1 o � No. Revision/Issue Date 1 Issue /3/2021 For: Cooke Construction, Inc 1276 NE Business Park PL Jensen Beach, FL 34957 C3� By_ Sheet Zwm Checked By: TIP DateM_3 : 2/3/2021 Scale: As Shown 0 a�'M