Loading...
HomeMy WebLinkAboutAPPROVED FL 5V 26GA_1225_17679-R6 1/29/2021 Florida Building Code Online FLOPIOA OVARTMENT OF Li iYl ait ProfessionalBusiness & Regulation r BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr Product Approval` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL17679-R6 SFCRETARY Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Drexel Metals,Inc. Address/Phone/Email 204 Railroad Drive Ivyland, PA 18974 (502) 303-1511 jshumate@drexmet.com Authorized Signature Jason Shumate jshumate@drexmet.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Architectural Testing,Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2025 Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL17679 R6 COI DRX15002.6 2020 FBC Eval Metal Roofing HVHZ final.pdf Referenced Standard and Year(of Standard) Standard Year ASTM B 117 2016 ASTM G 155 2013 TAS 100 1995 TAS 110 2000 TAS 125 2003 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFR%2bP9kYGhinRHUPuiAxDRkQtoa%2fGVEztq%2bg%3d%3d 1/2 1/29/2021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/09/2020 Date Validated 08/10/2020 Date Pending FBC Approval 08/20/2020 Date Approved 10/13/2020 Summary of Products FL# Model,Number or Name Description 17679.1 Drexel Metal Roofing Systems DMC 100NS, DMC 150SS, DMC 175S, DMC 200S, DMC 5V Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL17679 R6 II DRX15002.6 2020 FBC Eval Metal Roofing. Approved for use outside HVHZ: No HVHZ final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +0/-180 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL17679 R6 AE DRX15002.6 2020 FBC Eval Metal Roofing. HVHZ final.pdf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ZJ ® �A ® C,Pdit Cprd Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFR%2bP9kYGhinRHUPuiAxDRkQtoa%2fGVEztq%2bg%3d%3d 2/2 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: DREXEL METALS, INC. Issued August 9, 2020 1234 Gardiner Lane Louisville, KY 40213 (502)716-7143 www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM) Quality Assurance: Architectural Testing, Inc.,An Intertek Company(QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Edition: Florida Building Code, 7th Edition (2020) High-Velocity Hurricane Zones(HVHZ) Code Sections: 1518.9.1, 1523.1.1, 1523.6.5, 1523.6.5.2.4, 1523.6.5.2.4.1 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing(TST1558) 56842.02-122-18 TAS 100 1995 Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing(TST1558) 58641.02-122-44 TAS 100 1995 Architectural Testing(TST1527) H3245.01-450-18 TAS 125 2003 Architectural Testing(TST1527) H3245.02-450-18 TAS 100 1995 Architectural Testing(TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing(TST1527) H9058.01-450-18 TAS 125 2003 Architectural Testing(TST1527) H9058.03-450-18 TAS 100 1995 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0312-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016 TAS 110 2000 PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2013 TAS 110 2000 PRI Construction Materials Technologies(TST5878) DMC-002-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-030-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) HTL-013-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) HTL-014-02-01 TAS 100 1995 DRX15002.6 FL17679-R6 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L.LC PRODUCT DESCRIPTION DMC 10ONS Profile: 1 in. snap lock seam; Max.16 in. coverage .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Description: Non-structural, snap lock standing seam roof panel with integral perorated nail strip :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 ........................................................................................................................................................................................................................................................................................................................................................................................................................................ 16" 1° -"D.C. Profile:DMC 150SS 1.5 in. mechanical seam; Max. 16 in. coverage :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Description: Non-structural, mechanical lock standing seam roof panel :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy= min. 16 ksi; Shall conform with FBC Section 1507.4.3 .................................................................................................................................................................................................................................................................................................................................................................. Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. 8 I r 2 3n 12' 11s' 16" � _F DMC 175S Profile: 1.75 in. snap lock seam; Max. 18 in. coverage :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Description: Non-structural, snap lock standing seam roof panel :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: 0.032-inch (Fy=min. 24 ksi)or 0.040-inch (Fy= min. 20 ksi) Fluropon®coated ASTM B209 aluminum; Shall conform with FBC Section 1507.4.3 ........ ......... __ ......... ......... ......... ......... ......... ......... ......... ............................ Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90ASTM A792 or ASTM A653; Fy= min. 50 ksi; Shall conform with FBC Section 1507.4.3 .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. DRX15002.6 FL17679-R6 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L.LC DMC 200S Profile: 2 in. mechanical seam; Max. 16 in. coverage .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Description: Non-structural, mechanical lock standing seam roof panel .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 0.040 in. Fluropon®coated ASTM B209 aluminum; Fy= min. 20 ksi; Shall conform with FBC Section 1507.4.3 Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................... � 8 16 8 2" 2" I 16„ I DMC 5V Profile: 3/8 in. ribs; Min. 21 in., Max. 24 in.coverage .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Description: Non-structural, through fastened roof panel :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 26 ga. Fluropon®coated ASTM A792 or ASTM A653 G90 ; Fy= min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy= min. 19 ksi; Shall conform with FBC Section 1507.4.3 :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. 21"up to 24'Coverage { 8 LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3. Roof slope shall be 2:12 or greater. 4. Reroofing shall be in accordance with Section 1521. 5. Installation of the evaluated products shall comply with this report, RAS 133, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 6. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. DRX15002.6 FL17679-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. G�PRY R. p9/�,��, 2020.08.09 C.EN*"SF•F�, �' �'• 15. 10.24 No 74021 -04'00' -•• STATE O F 1JJ '.,0�•:c< O R �p?:•'���� Zachary R. Priest, P.E. S •••• •. Florida Registration No. 74021 ##;e1S�0NAll �� `�� Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A— Installation (9 pages) 2) APPENDIX B—Approved Roof Systems (5 pages) 3) APPENDIX C—Design Wind Loads(3 pages) DRX15002.6 FL17679-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L,LC APPENDIX A INSTALLATION Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion with s #10-13 PH wood screw resistant in accordance with FBC section 1507.4.4. Fasteners #10-16 DP3 PH self- drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be #14-13 DP1 PH self- corrosion resistant in accordance with FBC section 1507.4.4. drilling screw 311 Bearing Plates 18 ga. Bearing Plate 3-1 24 ga.SS in-seam clip7 yy 7„ 16 T 24 ga. DMC 150SS Clip 3„ T O 8 o � o 4„ 2, Clips 24 ga. in-seam clip 7 1 �„ 7n I 1B 24 ga. DMC 150SS Fixed T 1g Clip 0 o 16 �� Zq 22 ga.SS in-seam clip 18 16 _L -� Clips 22 ga. DMC 150SS Clip a T o 0 0 61 4n 3„ 4 DRX15002.6 FL17679-R6 Page 1 of 9 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L,LC APPENDIX A Component Product Installation Detail 22 ga. in-seam clip �161 18 22 ga. DMC 150SS Fixed 1 0 7 Clip e T 0 0 4 3"4 22 ga. base;24 ga.butterfly in-seam clip Y d~� DMC 150SS Butterfly Clip 22 ga. base;24 ga.butterfly in-seam clip DMC 150SS Continuous Butterfly Clip = 18 ga. in-seam clip 1�. Clips DMC 175S UL Clip e o DRX15002.6 FL17679-R6 Page 2 of 9 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L,LC APPENDIX A Component Product Installation Detail 22 ga.SS in-seam clip 4 1 7 DMC 200S Clip 2" T O 0 o 0 f$, � Y 3.1 18 ga. base;22 ga.butterfly in-seam clip;4.5 in.length DMC 200S Butterfly Clip lips(Cont'd) 18 ga. base;22 ga.butterfly in-seam clip; 120 in.length;top slider 12 in.o.c. DMC 200S Continuous Butterfly Clip Bostik 70-05A Sealants Bostik Chem-Calk 915 Shall be applied in continuous beads along the seam Fastening Details Nomenclature Attachment DMIC 1 ONS PANEL 10 - 13 PH A DMC 100NS Standard Mn DRX15002.6 FL17679-R6 Page 3 of 9 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L,LC APPENDIX A Fastening Details Nomenclature Attachment DMC 10ONS PANEL BOBTII 70-0 A ( - 3/16" BEADS) f ##10 - 13 PHW DMC 100NS Enhanced DMC 15OSS PANEL DMC 15OSS CONTINUOUS BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT DMC 150SS Continuous SUBSTRATE Butterfly DMC 150SS PANEL DMC 150SS BUTTERFLY CLIP (2)#10-13PHW UNDERLAYMENT DMC 150SS Butterfly SUBSTRATE DMC 15OSS PANEL 24 GA DMC 150SS FIXED CLIP (2)#10-13 PHW UNDERLAYMENT DMC 150SS Fixed-90 SUBSTRATE DRX15002.6 FL17679-R6 Page 4 of 9 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L,LC APPENDIX A Fastening Details Nomenclature Attachment DMC 15OSS PANEL 24 GA DMC 150SS CLIP (2)#10-13 PHW UNDERLAYMENT DMC 150SS Standard(Al) SUBSTRATE 114"BEAD BOSTIK 70-05A DMC 150SS PANEL 22 GA DMC 150SS FIXED CLIP DMC 150SS Fixed (2)#10-13 PHW Enhanced-90 UNDERLAYMENT SUBSTRATE DMC 150SS PANEL 22 GA DMC 150SS FIXED CLIP (2)#10-13PHW UNDERLAYMENT DMC 150SS Fixed SUBSTRATE Enhanced-180 DRX15002.6 FL17679-R6 Page 5 of 9 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX A Fastening Details Nomenclature Attachment 114"BEAD BOSTIK 70-05A t DMC 15OSS PANEL 22 GA DMC 15OSS CLIP (2)#10-13 PHW DMC 150SS Enhanced(Al) UNDERLAYMENT SUBSTRATE DMC 175S Panel DMC 175S UL Cip #10-13 PH Screw (2)per cop DMC 175S#10 Standard DMC 175S PANEL DMC 175S UL CLIP 914-13 DP1 PHDD(2 Per Clip) 3X3-18GA BEARING PLATE METAL DECK ISO INSULATION ]A DMC 175S#14 Standard DRX15002.6 FL17679-R6 Page 6 of 9 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L.LC APPENDIX A Fastening Details Nomenclature Attachment DMC 200S PANEL DMC 200S BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT SUBSTRATE DMC 200S Butterfly DMC 200S PANEL DMC 200S BUTTERFLY CLIP #10 - 16 DP3 PHD UNDERLAYMENT METAL DECK DMC 200S Butterfly(Steel) Use 18 ga.bearing plate over polyisocyanurate insulation DMC 200S PANEL DMC 200S CONTINOUS BUTTERLY CLIP #10 - 16 DP3 PHD UNDERLAYMENT METAL DECK DMC 200S Continuous Butterfly(Steel) Use 18 ga.bearing late over mlyisocyanurate insulation DRX15002.6 FL17679-R6 Page 7 of 9 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L,LC APPENDIX A Fastening Details Nomenclature Attachment DMC 200S PANEL DMC 200S CLIP (2)#10-13 PHW UNDERLAYMENT SUBSTRATE DMC 200S Fixed 1/4"BEAD BOSTIK 70-05A DMC 200S PANEL DMC 200S CLIP (2)#10-13 PHW DMC 200S Fixed Enhanced UNDERLAYMENT SUBSTRATE p9-15 HWH WOOD SCREW WITH SEALING WASHER DMC 5V Standard DRX15002.6 FL17679-R6 Page 8 of 9 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, L,LC APPENDIX A Fastening Details Nomenclature Attachment #10- 14 DREXMET WOODSCREW DMC 5V PANEL METSHIELD HT UNDERLAYMENT DMC 5V#10 Standard PLYWOOD DRX15002.6 FL17679-R6 Page 9 of 9 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure (MDP)was calculated using a 2:1 margin of safety per FBC Section 1523.4. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. 5. Underlayment shall be installed in accordance with FBC requirements. The minimum underlayment shall be ASTM D 226, Type II installed as described in FBC Section 1518.2.1 with nails and tin caps per 1517.5. 6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(Fy= min.40 ksi)Wide Rib Deck(Type WR) conforming to ANSI/SDI-RD1.0& FBC. In no case shall the panels be installed on less than two continuous spans,which are spaced a maximum 5-ft o.c. At minimum,the deck shall be attached with one (1)#12 x 1.5-inch HWH self-drilling screws at the bottom of each flute(maximum. 6-inch o.c.along the support). At minimum, the deck side laps shall be fastened a maximum 6-inch o.c.with#12 x 1.5-inch HWH self-drilling screws. 7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 19/32-inch thick APA Span-Rated plywood sheathing or wood plank at maximum 24-inch span for new construction. Existing construction shall be the minimum plywood sheathing or wood plank thickness at maximum 24-inch span as stated in the approval tables on following pages. In no case shall the attachment be less than 8d ring shank nails spaced 6-inch o.c. Roof System Numbers and Definitions 100NS-W# DMC 100NS over Wood Deck(New or Existing) 150SS-W# DMC 150SS over Wood Deck New or Existing) 175S-S# DMC 175S over Steel Deck New or Existing) 175S-W# DMC 175S over Wood Deck(new or Existing) 200S-S# DMC 200S over Steel Deck New or Existing) 200S-W# DMC 200S over Wood Deck(New or Existing) 5V W# DMC 5V over Wood Deck New or Existing) Approved Systems for DMC 100NS over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 10ONS-W1 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 10ONS DMC 100NS Standard attachment -97.5 CDX plywood Versashield Solo Max. 16-inch wide with fasteners spaced 10.5 in.o.c. 100NS-W2 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 10ONS DMC 100NS Standard attachment -120 CDX plywood Versashield Solo Max. 16-inch wide with fasteners spaced 5.25 in.o.c. 100NS-W3 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 10ONS DMC 100NS Enhanced attachment -135 CDX plywood Versashield Solo Max. 16-inch wide with fasteners spaced 5.25 in.o.c. DRX15002.6 FL17679-R6 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SS over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 15/32 OPTIONAL 0.032"Al DMC 150SS DMC 150SS Standard(Al)attachment 150SS-Wl CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -90 180'seam 150SS-W2 Min.plywood 24 ga. DMC 150SS OPTIONAL As required per FBC Max. 16-inch wide DMC 150SS Fixed-90 attachment -90 CDX pllywood Versashield Solo 90'seam with clips spaced 16 in.o.c. DMC 150SS Min. 15/32 OPTIONAL 24 ga. DMC 150SS Butterfly attachment 150SS-W3 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -99.25 180'seam DMC 150SS Min. 15/32 OPTIONAL 24 ga. DMC 150SS Continuous Butterfly attachment 150SS-W4 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with fasteners spaced 12 in.o.c. -114.25 180'seam DMC 150SSa. Min. 15/32 OPTIONAL 24 g DMC 150SS Fixed Enhanced-90 attachment 150SS-W5 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 12 in.o.c. -150 Min.90'seam DMC 150SS Min. 15/32 OPTIONAL 24 ga. DMC 150SS Fixed Enhanced- 180 attachment 150SS-W6 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 8 in.o.c. -165 Min. 180'seam 032"AlDMC 150SS Min. 15/32 OPTIONAL 0. DMC 150SS Enhanced(Al)attachment 150SS-W7 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 8 in.o.c. -180 180'seam Approved Systems for DMC 175S over Steel Deck(New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 1 in.Approved Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment 175S-S1 As required polyisocyanurate As required per FBC -88 Type B Steel insulation board Max. 17.5-inch wide with clips spaced 18 in.o.c. DRX15002.6 FL17679-R6 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 175S over Steel Deck(New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 1 in.Approved Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment 175S-S2 As required polyisocyanurate As required per FBC -129.25 Type B Steel insulation board Max. 17.5-inch wide with clips spaced 12 in.o.c. Approved Systems for DMC 175S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) ASTM D 226,Type II roofing felt attached per 175S-WI Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 0.032"Al DMC 175S DMC 175S#10 Standard attachment -74.75 CDX plywood followed by Metshield High-Temp Max. 18-inch wide with clips spaced 24 in.o.c. Underlayment self-adhered to felt Min. 15/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment 175S-W2 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 16 in.o.c. -84.25 Solo Min. 15/32 OPTIONAL 0.040"Al DMC 175S DMC 175S#10 Standard attachment 175S-W3 CDX plywood Versashield As required per FBC Max. 17.5-inch wide with clips spaced 18 in.o.c. -106.75 Solo Min. 15/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment 175S-W4 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 8 in.o.c. -121.75 Solo ASTM D 226,Type II roofing felt attached per 175S-W5 Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 0.032"Al DMC 175S DMC 175S#10 Standard attachment -131 CDX plywood followed by Metshield High-Temp Max. 18-inch wide with clips spaced 6 in.o.c. Underlayment self-adhered to felt Approved Systems for DMC 200S over Steel Deck(New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 1 in.Approved 24 ga. DMC 200S Min.22 ga. DMC 200S Butterfly(Steel)attachment 200S-S1 As required polyisocyanurate As required per FBC Max. 16-inch wide -88 Type B Steel insulation board 180'seam with clips spaced 24 in.o.c. DRX15002.6 FL17679-R6 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 200S over Steel Deck(New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.22 ga. 24 ga. DMC 200S DMC 200S Butterfly(Steel)attachment 200S-S2 Type B Steel As required None As required per FBC Max. 16-inch wide with clips spaced 24 in.o.c. -91.75 180'seam Min.22 ga. Min. 1 in.Approved 24 ga. DMC 200S DMC 200S Continuous Butterfly(Steel) 200S-S3 As required polyisocyanurate As required per FBC Max. 16-inch wide -121.75 Type B Steel insulation board 180'seam attachment with clips spaced 12 in.o.c. Min.22 ga. 24 ga. DMC 200S DMC 200S Continuous Butterfly(Steel) 200S-S4 Type B Steel As required None As required per FBC Max. 16-inch wide attachment with clips spaced 12 in.o.c. -151.75 180'seam Approved Systems for DMC 200S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 040"AlDMC 200S Min. 19/32 OPTIONAL As required per 0. DMC 200S Fixed attachment 200S-Wl CDX plywood Versashield Solo FBC Max. 16-inch wide with clips spaced 16 in.o.c. -105 180'seam 040"AlDMC 200S Min. 19/32 OPTIONAL As required per 0. DMC 200S Fixed Enhanced attachment 200S-W2 CDX plywood Versashield Solo FBC Max. 16-inch wide with clips spaced 8 in.o.c. -180 180'seam Approved Systems for DMC 5V over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) ASTM D 226,Type II roofing felt attached 0.032"Al DMC 5V DMC 5V#10 Standard attachment 5V-W1 Min. 15/32 OPTIONAL per 1518.2.1 with nails and tin caps per Min.21-inch to with#10-14 HWH wood screws with -56 CDX plywood Versashield Solo 1517.5 followed by Metshield High-Temp Max.24-inch coverage sealing washers spaced 18 in.o.c. Underlayment self-adhered to felt DRX15002.6 FL17679-R6 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 5V over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 5V-W2 Min. 15/32 OPTIONAL As required per FBC Min.21-inch to 26 ga, DMC 5V DMC 5V Standard attachment -60 CDX plywood Versashield Solo Max.24-inch coverage with clips spaced 16 in.o.c. ASTM D 226,Type II roofing felt attached 26 ga. DMC 5V DMC 5V#10 Standard attachment 5V-W3 Min. 15/32 OPTIONAL per 1518.2.1 with nails and tin caps per Min.21-inch to with#10-14 HWH wood screws with -71 CDX plywood Versashield Solo 1517.5 followed by Metshield High-Temp Max.24-inch coverage sealing washers spaced 24 in.o.c. Underlayment self-adhered to felt Min. 15/32 OPTIONAL 26 ga, DMC 5V DMC 5V Standard attachment 5V-W4 CDX plywood Versashield Solo As required per FBC Min.21-inch to with clips spaced 8 in.o.c. -121.75 Max.24-inch coverage ASTM D 226,Type II roofing felt attached 26 ga. DMC 5V or DMC 5V#10 Standard attachment 5V-W5 Min. 15/32 OPTIONAL per 1518.2.1 with nails and tin caps per 0.032"Al DMC 5V with#10-14 HWH wood screws with -206 CDX plywood Versashield Solo 1517.5 followed by Metshield High-Temp Min.21-inch to sealing washers spaced 6 in.o.c. Underlayment self-adhered to felt Max.24-inch coverage DRX15002.6 FL17679-R6 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1620 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1620 of the FBC. 2. Exposure C and D shall be as defined in section 1620 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd=0.85 8. Design wind loads are calculated using Pasd =0.6PUit• 9. Zone 2 is inclusive of Zone 2e,Zone 2n, and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 12. Zones 1,2, and 3 shall be defined as shown below. Dimension"a"shall be 10% of the least horizontal dimension or(0.4 x Mean Roof Height),whichever is smaller, but not less than either 4%of the least horizontal dimension or 3ft Gable Hip 3 2 3 3 2 3 a 3 2 3 a 2 1 2 2 1 2 2 1 2 2 1 2 3 2 3 LL.2___A a 3 2 3 a a Iola la al al- DRX15002.6 FL17679-R6 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure C in Miami-Dade&Broward County(Roof slopes between 2:12 and 12:12) Basic Wind Speed(mph) Building Type Zone Mean Roof Risk Cat I Risk Cat I Risk Cat II Risk Cat II Risk Cat III, IV Risk Cat III,IV Height(ft) 156 165 170 175 180 186 20 -62.3 -69.7 -74.0 -78.5 -83.0 -88.6 25 -65.1 -72.8 -77.3 -81.9 -86.7 -92.6 1 30 -67.9 -75.9 -80.6 -85.4 -90.4 -96.5 40 -72.0 -80.6 -85.6 -90.7 -95.9 -102.4 50 -75.5 -84.5 -89.7 -95.0 -100.5 -107.3 60 -78.3 -87.6 -93.0 -98.5 -104.2 -111.3 20 -90.9 -101.7 -108.0 -114.4 -121.1 -129.3 25 -95.0 -106.3 -112.8 -119.5 -126.5 -135.0 Enclosed/ 30 -99.0 -110.8 -117.6 -124.6 -131.8 -140.8 Partially Open 2 40 -105.1 -117.6 -124.8 -132.2 -139.9 -149.4 50 -110.1 -123.2 -130.8 -138.6 -146.6 -156.6 60 -114.2 -127.7 -135.6 -143.7 -152.0 -162.3 20 -108.1 -120.9 -128.4 -136.0 -143.9 -153.7 25 -112.9 -126.3 -134.1 -142.1 -150.3 -160.5 3 30 -117.7 -131.7 -139.8 -148.1 -156.7 -167.3 40 -124.9 -139.7 -148.3 -157.2 -166.3 -177.6 50 -130.9 -146.5 -155.5 -164.7 -174.3 -186.1 60 -135.7 -151.8 -161.2 -170.8 -180.7 -192.9 20 -72.9 -81.6 -86.6 -91.8 -97.1 -103.7 25 -76.2 -85.2 -90.4 -95.8 -101.4 -108.3 1 30 -79.4 -88.8 -94.3 -99.9 -105.7 -112.9 40 -84.3 -94.3 -100.1 -106.0 -112.2 -119.8 50 -88.3 -98.8 -104.9 -111.1 -117.6 -125.5 60 -91.6 -102.4 -108.7 -115.2 -121.9 -130.2 20 -101.5 -113.6 -120.6 -127.8 -135.2 -144.3 25 -106.0 -118.6 -125.9 -133.4 -141.2 -150.7 Partially 30 -110.5 -123.7 -131.3 -139.1 -147.2 -157.1 Enclosed 2 40 -117.3 -131.2 -139.3 -147.6 -156.2 -166.8 50 -123.0 -137.5 -146.0 -154.7 -163.7 -174.8 60 -127.5 -142.6 -151.4 -160.4 -169.7 -181.2 20 -118.7 -132.8 -140.9 -149.3 -158.0 -168.7 25 -124.0 -138.7 -147.2 -156.0 -165.0 -176.2 3 30 -129.2 -144.6 -153.5 -162.6 -172.0 -183.7 40 -137.1 -153.4 -162.9 -172.6 -182.6 -195.0 50 -143.7 -160.8 -170.7 -180.9 -191.4 -204.3 60 -149.0 -166.7 1 -177.0 -187.5 -198.4 -211.8 DRX15002.6 FL17679-R6 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK Metal METALS, INC. Metal Roofing(HVHZ) TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure D in Miami-Dade&Broward County(Roof slopes between 2:12 and 12:12) Basic Wind Speed mph Building Type Zone Mean Roof Risk Cat I Risk Cat I Risk Cat II Risk Cat II Risk Cat III, IV Risk Cat III,IV Height(ft) 156 165 170 175 180 186 20 -74.8 -83.7 -88.8 -94.1 -99.6 -106.3 25 -77.6 -86.8 -92.1 -97.6 -103.3 -110.3 1 30 -80.4 -89.9 -95.4 -101.1 -107.0 -114.2 40 -84.5 -94.5 -100.4 -106.3 -112.5 -120.1 50 -88.0 -98.4 -104.5 -110.7 -117.1 -125.1 60 -90.7 -101.5 -107.8 -114.2 -120.8 -129.0 20 -109.1 -122.1 -129.6 -137.3 -145.3 -155.1 25 -113.2 -126.6 -134.4 -142.4 -150.7 -160.9 Enclosed/ 30 -117.2 -131.1 -139.2 -147.5 -156.0 -166.6 Partially Open 2 40 -123.3 -137.9 -146.4 -155.1 -164.1 -175.2 50 -128.3 -143.6 -152.4 -161.5 -170.8 -182.4 60 -132.4 -148.1 -157.2 -166.6 -176.2 -188.2 20 -129.7 -145.1 -154.0 -163.2 -172.7 -184.4 25 -134.5 -150.5 -159.7 -169.3 -179.1 -191.2 3 30 -139.3 -155.9 -165.4 -175.3 -185.5 -198.1 40 -146.5 -163.9 -174.0 -184.4 -195.1 -208.3 50 -152.5 -170.6 -181.1 -192.0 -203.1 -216.8 60 -157.3 -176.0 -186.8 -198.0 -209.5 -223.7 20 -87.5 -97.9 -103.9 -110.1 -116.5 -124.4 25 -90.7 -101.5 -107.8 -114.2 -120.8 -129.0 1 30 -94.0 -105.1 -111.6 -118.3 -125.1 -133.6 40 -98.8 -110.6 -117.4 -124.4 -131.6 -140.5 50 -102.9 -115.1 -122.2 -129.5 -137.0 -146.3 60 -106.1 -118.7 -126.0 -133.6 -141.3 -150.9 20 -121.8 -136.3 -144.7 -153.3 -162.2 -173.2 25 -126.3 -141.3 -150.0 -159.0 -168.2 -179.6 Partially 30 -130.8 -146.4 -155.4 -164.7 -174.2 -186.0 Enclosed 2 40 -137.6 -154.0 -163.4 -173.2 -183.2 -195.6 50 -143.3 -160.3 -170.1 -180.3 -190.7 -203.6 60 -147.8 -165.3 -175.5 -186.0 -196.7 -210.1 20 -142.4 -159.3 -169.1 -179.2 -189.6 -202.5 25 -147.7 -165.2 -175.4 -185.8 -196.6 -210.0 3 30 -153.0 -171.1 -181.6 -192.5 -203.6 -217.4 40 -160.9 -180.0 -191.0 -202.4 -214.2 -228.7 50 1 -167.5 1 -187.3 1 -198.9 1 -210.7 1 -223.0 1 -238.1 60 -172.7 -193.2 -205.1 -217.4 -230.0 -245.6 DRX15002.6 FL17679-R6 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.